MAXIGARD A2000 SPEED SWITCH. Introduction

Similar documents
C3000 SIGNAL TRANSMITTER. Introduction

CM3000 SIGNAL TRANSMITTER. Introduction. The MAXIGARD CM3000 is designed to convert shaft speed into a 4/20 ma or 0-10 VDC analog output signal.

A1500, A1500NF SPEED SWITCH SINGLE SET POINT - SELF CONTAINED. Introduction

A5000GEC-24VDC ZERO SPEED SWITCH

B2000 SERIES TACHOMETERS DIGITAL OR ANALOG DISPLAYS

PRODUCT INFORMATION BULLETIN

Electric Actuator Installation, Operation & Maintenance Manual

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

Operations Manual. Zero Speed Switch Sensor Model ZS09P

CBC-300 & CBC Series Dual Channel Adjust Clutch/Brake Controls

INSTRUCTION MANUAL MODEL # YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC.

Model 550 Series Vibration Switches

Pump Installation and Service Manual HRS Hydromatic Retractable System

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

SPC-PANEL Simplex, Single Phase Pump Control Panel

MODEL RMS INSTALLATION INSTRUCTIONS. CONTENTS Page A. Introduction 1. Usage 2 2. How it operates 2

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

PRO REMOTE Series CAPACITANCE PROBE

Switch Pro w/ Compact Junction Box A_1_ Series Owner s Manual

HYGRODYNAMICS DIGITAL DEW POINT MONITOR PC BOARD MODEL 6392N & 6392N2 TABLE OF CONTENTS

INSTALLATION MANUAL ACL 5500 COMBUSTION SAFETY CONTROLLER

BMRX Series ROTARY LEVEL CONTROL

AUTO ISOLATOR I AN AUTOMATIC LOSSLESS BATTERY ISOLATOR FOR DUAL BATTERY SYSTEMS

INSTRUCTION MANUAL. A battery protector for vehicles with equipment that Is operated with the engine not running. MODEL# INPUT: 12 Volts D.C.

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

CRICKET Alphasonic Level Transmitter Model LA12 Owner s Manual

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

32XR. 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide

SG1000A Slide Gate Sensor Slide Gate & Valve Position

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

CBC-160-1N and CBC-160-2N Clutch/Brake Controls

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Installation and Service Instructions for EX Series Explosion-proof Switches

Boston Gear Ratiotrol DC Motor Speed Control

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

5600 Series Power Operator Installation and Instruction Manual

Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB

MOTORTRONICS Solid State AC Motor Control

PRO REMOTE 25 LV CAPACITANCE PROBE

UV DISINFECTION UNIT MODEL 3G

Air Curtain. Installation, Operating and Maintenance Instructions

LX-80 COMMERCIAL POOL & SPA CONTROL INSTALLATION INSTRUCTIONS

SAFTRONICS DF8 PLUS SERIES

ICI Indelac Controls, Inc. Installation, Operation & Maintenance Manual For Electric Spring Return Actuator

Gen 2 Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB

All products subject to this warranty must be returned for examination, repair or replacement to:

Graham. Vari Speed S1000 Instruction Manual. TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual

12 Series Linear Actuators. Operation & Maintenance Manual, Analog Positioner Installation

TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 SAFETY SUMMARY INTRODUCTION INSTALLATION Location and Mounting Input

MODEL CMS INSTALLATION INSTRUCTIONS A. INTRODUCTION 1. USAGE 2 2. HOW IT OPERATES 2 B. SPECIFICATIONS 1. ELECTRICAL 3 2.

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Shaft Speed Switches. SCP Series Speed Switch. M Series Speed Switch M100T/M5000T. Our Most Popular Speed Switch!

Installation & Maintenance of the Fresh-Aire UV Airborne Duct System for Commercial HVAC Systems. Parts Included. Optional Parts

Filtered PWM Speed Control for Permanent Magnet DC Motors

INSTRUCTION MANUAL INSTALLATION, OPERATION, AND MAINTENANCE ACTUATOR MANIFOLD

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

COMMUNICATIONS SETUP DBS STARTER PANEL

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

Installation and Operation Guide

Updated: October 2012

MODEL MSD MOTION CONTROL INSTALLATION AND OPERATION

Model 616 Rotating Disk Electrode Instruction Manual

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL

Warner Electric UNIBRAKE Motor Brakes

SUBMERSIBLE SUMP PUMPS

Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB Size 50, 100, 180

INSTALLATION AND OPERATION MANUAL

Electro-Brake 375, 475, 650, 825, 1000, 1225

Switch-Pak. AU13, AV13 & AZ13 Series Owner s Manual. w/ Compact Relay Controller

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

Primary Brake Spline Drive Armature PB-825, PB-1000, PB-1225, PB-1525

AUTOMATIC SUBMERSIBLE UTILITY PUMP

MDCSL V, 30A

Owner s Guide ca4054 ca4554

Owner s Guide CA 4555

Terminal Assembly Machine

Model C230 Pump Controller

TB Series Brakes Tension Control System

MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES,

SP-32 & SP-32D SP-33, SP-33D SP-34, SP-34D. Description. Specifications. Single Stage Temperature Control

5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE

½ DODGE CUMMINS OEM BYPASS LIFT PUMP KIT Installation Instructions Part #

INSTALLATION/OPERATING INSTRUCTIONS TSC

EG1065X. Compatible with Barber Colman* Dyn1-1065X series * Use for reference purpose only and not a genuine Barber Colman product.

MPT-250B SPECIFICATIONS AND OPERATING INSTRUCTIONS

MBDC V. 110VAC Input Brush DC Controller. User s Guide East Landon Drive, Anaheim, CA

Model 116 DPI Switch Installation and Operating Instructions

RK Standby Battery Operator s Manual

Models DTT-84, DTT-94

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

ODY-05-2 VOLTMETER FOR REMOTE MONITORING

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

INSTALLATION & OWNER'S MANUAL

Model GD-70D4A-XX Supplement to the GD-70D Operator s Manual

Level Alert Model Multi-Switch Liquid Level Sensor. Assembly and Installation Instructions

Two Channel Remote Shutdown Device

Motoweigh Dynamic In-motion Checkweighing System. Installation Manual

2.11. Limit Switches. Contents Description. Special Purpose Limit Switches. Special Purpose Limit Switches

Transcription:

A107-05, Page 1 952-361-3026, INC. (Fax) 952-368-4129 327 LAKE HAZELTINE DRIVE, CHASKA, MN 55318 800-328-0738 MAXIGARD A2000 SPEED SWITCH Introduction The Maxigard A2000 Speed Switch is designed to monitor the rotation of critical driven shafts. The switch is precision built of quality material and completely factory tested to insure long life and trouble free operation. Principle of Operation The Maxigard A2000 speed switch is supplied with a non-contacting sensor and magnetic target. The sensor signal is not impaired by buildup of dust or any other foreign material on the magnet target or sensor. The A2000 has two adjustable set points and is designed to detect under speed and/or over speed of the monitored shaft. The low set point relay has a built in power up time delay of approximately 7 seconds which allows machinery controlled through the motor starter circuit to reach the set point during start-up. The delay activates on power-up only and can be disabled with a field selectable jumper pin configuration. When properly installed and calibrated, in the event of a power failure or loss of sensor signal the relays will de-energize and put the switch into an alarm condition. Components THE MAXIGARD A2000 SPEED SWITCH INCLUDES: 4 MAGNET DISC (OTHER OPTIONAL MAGNETIC TARGETS AVAILABLE) SENSOR WITH 10 OF CABLE AND MOUNTING BRACKET A2000 SPEED SWITCH CIRCUIT BOARDS WITH TWO 10 AMP RELAYS NEMA 4 ENCLOSURE

A107-05, Page 2 SECTION 1 - MECHANICAL 1.0 Magnet Disc 1.1 The end of the shaft to be monitored should be square to prevent excessive disc wobble. 1.2 Center drill and tap the shaft end. (Suggested #21 drill and #10-32NF tap). Bolt the magnet disc to the end of the shaft. Use Loc-tite to keep the bolt and disc tight on the shaft. (see figure 1A & 1C, page 3). 2.0 Magnet Wrap (optional) 2.1 Separate the two halves of the magnet wrap by loosening the cap screws holding the two halves together. 2.2 Place both halves of the magnet wrap around the shaft. Re-insert and tighten the cap screws making sure the wrap is square to the shaft. (see figure 1B & 1D, page 3). NOTE There will be a slight gap between the two halves after tightening. This gap will not affect the generated signal. 3.0 Mounting the Sensor 3.1 Place the sensing head so it is centered directly in front of the magnets in the disc or optional wrap. (see figure 1A & 1B, 1C & 1D page 3). 3.2 The gap setting between the sensor and magnet disc should be approximately 1/8-7/8.

SENSING METHOD A107-05, Page 3 STANDARD SENSING HEAD & MAGNETIC DISC STANDARD SENSING HEAD & MAGNETIC WRAP 1/8" to 7/8" GAP MAGNET SENSOR MAGNET 1/8" to 7/8" GAP SENSOR MAGNET DISC Figure 1A MAGNET WRAP Figure 1B XP SENSING HEAD & MAGNETIC DISC XP SENSING HEAD & MAGNETIC WRAP 1/8" to 7/8" GAP MAGNET MAGNET 1/8" to 7/8" GAP 1 5/8" Figure 1C Figure 1D 1/4" 4" DIMENSIONAL DATA 1 1/2" 5/16" 2 1/2" 1 1/2" 10 1 1/2" 1 1/2" 5/16" 2 1/2" 10 3/4" 1/2" NPS 3/4" 1/2" NPS 3/16" 1 3/8" 2" MATERIAL: RED ANODIZED ALUMINUM 1 3/8" 2" MATERIAL: PVC STANDARD MAGNET DISC STANDARD SENSING HEAD AND MOUNTING BRACKET NEMA 4X SENSING HEAD AND MOUNTING BRACKET 1 1/2" D"+3" 1 1/2" 3" 1 1/2" 15/16" 2" 5/8" 5/8" 4" 5/16" X 1" 1" 2 1/2" D" 7/8" 10 OPTIONAL MAGNET WRAP XP SENSING HEAD AND MOUNTING BRACKET Figure 2

A107-05, Page 4 4.0 Speed Switch Enclosure 4.1 A2000 enclosures are UL listed/ CSA approved, rated NEMA 4, dust tight, oil tight and water tight painted carbon steel construction suitable for indoor and outdoor use. NEMA 4X fiberglass or stainless steel are available. (see figure 3A & 3B, page 4) CAUTION Remove the circuit board from the enclosure before punching or drilling conduit holes. Be sure to remove all metal chips and filings. NEMA 4 PAINTED CARBON STEEL NEMA 4X FIBERGLASS 6" 3 1/2" 6 15/16" 4 1/4" 8" 8 3/4" 8 1/2" 9 1/8" 4" 5/16" 4" 5/16" Figure 3A Figure 3B

A107-05, Page 5 SECTION 2 - FIELD WIRING 5.0 Sensor Wiring 5.1 Connect the sensor cable to terminals black, white and shield located on terminal block TB1. (see figure 4, page 6) 5.2 The sensor comes standard with 10 of cable. Additional cable can be added as required. Be sure to maintain continuity. Wrap the splice with the foil shield and electrical tape. SENSING HEAD CABLE Use Belden #8761 or equal. Cable should not be run in same conduit as power wires. Maximum distance of cable run 10,000 ft. Make good splice connections and check continuity. 6.0 Wiring the A2000 Speed Switch WARNING To avoid electrical shock disconnect all sources of power to the motor starter before wiring and observe voltage ratings of the speed switch. 6.1 Power connections and relay connections to the A2000 Speed Switch are shown on Figure 4, page 6. Also, figures 5, 6 and 7 show typical wiring diagrams. 6.2 Connect 120 VAC power to L1 and neutral to L2 on terminal block TB2 (see figure 4, page 6). See figures 5, 6 and 7 for examples of typical wiring diagrams. Connect equipment safety ground to GRD on terminal block TB2. 6.3 Make relay connections to terminal block TB2. Normally open contacts are held closed and normally closed contacts are held open when the operating speed exceeds the set point speed for that particular relay contact. (see figure 4, page 6)

TACH CALIBRATION P3 - A107-05, Page 6 6 7/8" 6 1/4" PN 1325 CIRCUIT BOARD PN 1350 CIRCUIT BOARD PN 1142 CIRCUIT BOARD HIGH SET POINT P2 LOW SET POINT P1 SW1 SPEED RANGE SELECTION DIP SWITCH SLIDE SWITCH TP1 OP TP2 TB1 WHT BLK SHLD + SENSOR CONNECTION OPTIONAL TACH OUTPUT 4 1/4" 4 7/8" TB2 GRD L2 L1 1 2 3 4 5 6 7 8 9 10 11 12 NO NC NO NC NO NC NO NC 120VAC POWER CONNECTION HIGH SETPOINT RELAY CONTACTS LOW SETPOINT RELAY CONTACTS Figure 4

A107-05, Page 7 TYPICAL WIRING TO MOTOR STARTER 120VAC N L1 A2000 L2 GND STOP START OL s LOW SP 7 LOW SP 10 8 9 11 M AUX M HIGH SP 1 HIGH SP 4 12 2 3 5 6 Figure 5 When the start pushbutton is pressed the A2000 speed switch is powered on and a power on delay of approximately 7 seconds begins. During the power on delay the low set point relay contacts are held in the switched position allowing the motor to run. As long as the monitored shaft speed is above the low set point speed before the power on delay period has expired, the relay contacts will remain in the switched position allowing the monitored machine to run normally. If the monitored shaft speed slows down or stops below the low set point speed the relay contact holding in the motor starter contact will open and drop out the motor starter. The power on delay is reset when the motor starter drops out and power is interrupted to the A2000. The power on delay can be disabled by reconfiguring the time delay jumper pins. (see figure 8, page 10) An additional set point is available to sound an alarm horn, turn on another type of warning device, or interlock with other equipment.

A107-05, Page 8 TYPICAL WIRING TO MOTOR STARTER 120VAC N L1 A2000 L2 GND STOP START OL s LOW SP 7 LOW SP 10 8 9 11 M AUX M HIGH SP 1 HIGH SP 4 12 2 3 5 6 When 120 VAC is applied to L1 and L2 the A2000 speed switch is powered on and a power on delay of approximately 7 seconds begins. During the power on delay the low set point relay contacts are held in the switched position allowing the motor to run. As long as the monitored shaft speed is above the low set point speed before the power on delay period has expired, the relay contacts will remain in the switched position allowing the monitored machine to run normally. If the monitored shaft speed slows down or stops below the low set point speed the relay contact holding the motor starter contact will open and drop out the motor starter. The power on delay is reset when power is removed from L1 and L2. If the A2000 is powered continuously the power on delay only occurs at initial power up and is not available for later restarts. If continuously powered the start pushbutton will need to be held closed until the monitored shaft reaches operating speed allowing the motor starter to seal through the motion switch contact. The power on delay can be disabled by reconfiguring the time delay jumper pins. (see figure 8, page 10) Figure 6 An additional set point is available to sound an alarm horn, turn on another type of warning device, or interlock with other equipment.

A107-05, Page 9 TYPICAL WIRING TO PLC OR CONTROL RELAY 120VAC N L1 A2000 L2 GND PLC Input Module - 120VAC I:001/01 LOW SP 7 LOW SP 10 8 9 11 I:001/02 I:001/03 I:001/04 HIGH SP 1 12 2 HIGH SP 4 3 5 6 CR When 120 VAC is applied to L1 and L2 the A2000 speed switch is powered on and a power on delay of approximately 7 seconds begins. During the power on delay the low set point relay contacts are held in the switched position allowing the motor to run. As long as the monitored shaft is above the set point speed before the power on delay period has expired, the relay contacts will remain in the switched position. If the monitored shaft speed stops or slows down below the set point speed the relay contacts open. When the monitored shaft speed exceeds the set point the relay contacts close. The power on delay is reset when power is removed from L1 and L2. If the A2000 is continuously powered the power on delay only occurs at initial power up. The power on delay can be disabled by reconfiguring the time delay jumper pins. (see figure 8, page 10) Figure 7

A107-05, Page 10 SECTION 3 - CALIBRATION 7.0 A2000 Speed Switch Calibration 7.1 Set the A2000 dip switches for the proper speed range based on the normal operating speed of the monitored shaft. The dip switch is located on the low set point circuit board. (see figure 8, page 10) SW1 ON 123 DIP SWITCH POT P1 SETPOINT ADJUSENT POT P3 TACHOMETER CALIBRATION (OPERATING SPEED) TIME DELAY JUMPER SETTINGS ENABLED DISABLED TIME DELAY JUMPERS ON ON ON ON ON 123 123 123 123 123 0 to 250 RPM 250 to 600 RPM 600 to 800 RPM 800 to 3000 RPM 3000 to 5000+ RPM Figure 8 8.0 A2000 Start Delay Configuration 8.1 The A2000 can be configured with or without a 7 second start delay. With the start delay feature enabled the A2000 low set point relay will automatically energize for 7 seconds upon power-up. This feature is used to allow the monitored shaft to reach the set point speed during start up without causing an alarm condition. If the shaft has not reached the low set point speed before the 7 second start delay period has expired, then the A2000 switch will go into an alarm condition. With the start delay feature disabled the A2000 relays will not energize until the monitored shaft speed exceeds the calibrated set point. (see figure 8, page 10) CALL TOLL FREE 800-328-0738

A107-05, Page 11 9.0 Calibration with Voltmeter If the optional tachometer is not supplied with the A2000, a voltmeter can be used to calibrate the speed switch. Connect the voltmeter leads to terminal block TB1 optional tach output connections (+) and (-). (see figure 10, page 13) 9.1 To calibrate the operating speed place the slide switch in the operating speed position (OP). With the machine running at normal operating speed adjust potentiometer P3 (CCW to increase/cw to decrease) until the voltmeter reads the recommended DC voltage as shown on table 1. USE P3 TO ADJUST USE P1/P2 TO ADJUST OPERATING SPEED RPM REMENDED 100% TACH OUTPUT VOLTAGE (OPERATION SPEED) 120% 110% 90% 80% 70% SETPOINT SETPOINT SETPOINT SETPOINT SETPOINT VOLTAGE VOLTAGE VOLTAGE VOLTAGE VOLTAGE 5-20 0.10 0.12 0.11 0.09 0.08 0.07 20-30 0.20 0.24 0.22 0.18 0.16 0.14 30-50 0.25 0.30 0.28 0.23 0.20 0.18 50-200 0.50 0.60 0.55 0.45 0.40 0.35 250+ 1.00 1.20 1.10 0.90 0.80 0.70 Table 1

A107-05, Page 12 9.2 To calibrate the low set point place the slide switch in the low set point position (TP1). Calculate the desired set point value by taking a percentage of the operating speed tach output voltage from table 1. EXAMPLE If the operating speed of the monitored shaft is 300 RPM set P3 for a voltmeter reading of 1.00 VDC while the machine is running at 100%. For an 80% set point (240 RPM) set P1 for a voltmeter reading of.80 VDC. (1.00 VDC x 80% =.80 VDC) (see table 1) Adjust potentiometer P1 until you reach the desired set point on the voltmeter (CW to increase/ CCW to decrease). The machine does not need to be running to make this adjustment. (see figure 10, page 13) 9.3 To calibrate the high set point place the slide switch in the high set point position (TP2). Calculate the set point value by taking a percentage of the operating speed tach output voltage from table 1. Adjust potentiometer P2 until you reach the desired set point on the voltmeter (CW to increase/ CCW to decrease). The machine does not need to be running to make this adjustment. (see figure 9, page 12/ Figure 10 page 13) 9.4 Return the slide switch to the OP position. The meter will now display the operating voltage. The set points will still function properly if the slide switch is in the TP position. (see figure 10, page 13) 9.5 A2000 speed switch is now calibrated. POT P2 HIGH SETPOINT ADJUSENT Figure 9

- A107-05, Page 13 10.0 Calibration with Optional Tachometer If the optional tachometer is supplied with the A2000 connect the meter as shown in figure 10, page 13. 10.1 To calibrate the operating speed place the slide switch in the operating speed position (OP). With the machine running at normal operating speed adjust potentiometer P3 until the display meter reads 100% (CCW to increase/ CW to decrease). (see figure 10, page 13) 10.2 To calibrate the low set point place the slide switch in the low set point position (TP1). Adjust potentiometer P1 until you reach the desired set point on the display meter (CW to increase/ccw to decrease). The machine does not need to be running to make this adjustment. (see figure 10, page 13) 10.3 To calibrate the high set point place the slide switch in the high set point position (TP2). Adjust potentiometer P2 until you reach the desired set point on the display meter (CW to increase/ CCW to decrease). The machine does not need to be running to make this adjustment. (see figure 10, page 13) 10.4 Return the slide switch to the OP position. The meter will now display the operating speed. The set points will still function properly if the slide switch is in the TP position. (see figure 10, page 13) 10.5 The A2000 speed switch is now calibrated. TACH CALIBRATION P3 HIGH SET POINT P2 LOW SET POINT P1 SW1 SPEED RANGE SELECTION DIP SWITCH SLIDE SWITCH TP1 OP TP2 TB1 WHT BLK SHLD SENSOR CONNECTION OPTIONAL TACHOMETER 0 100 + TB2 OPTIONAL TACH OUTPUT POT P1 CW = INCREASE CCW = DECREASE POT P2 CW = INCREASE CCW = DECREASE % RPM 2 3 4 5 6 7 8 9 GRD L2 L1 1 10 11 12 NO NC NO NC NO NC NO NC POT P3 CCW = INCREASE CW = DECREASE Figure 10

A107-05, Page 14 SPARE PARTS LIST Part No. Description 1142 A2000 Power Supply Circuit Board Without Relays 1325 Low Set Point Circuit Board 1350 High Set Point Circuit Board 1129 Standard Sensor With 10 Cable 1130 Standard Sensor Mounting Bracket With Jam Nuts 1132 Explosion Proof Sensor With 10 Cable 1134 Explosion Proof Sensor Mounting Bracket 1136 4 Magnet Disc 1320 Relay DPDT - 10 AMP @ 120 VAC LIMITED WARRANTY Process Control Systems, Inc. will repair or replace, at their option, F.O.B. factory, any part or unit which proves to be defective in material or workmanship within five years of purchase date, provided that part of the unit was installed and operated as recommended, to be established by examination of the part or unit at the factory. Goods returned under warranty must be shipped prepaid to the factory and accompanied by the serial number, description of defect, order number and date of purchase. This warranty shall not apply to any Maxigard product which shall have been repaired or altered outside of the Process Control Systems factory or has been subject to misuse, negligence or accident. Process Control Systems, Inc. warrants its products, but not their application, and shall not be liable for any incidental or consequential damages incurred through the use or loss of use of a Process Control Systems product. No representatives or other person is authorized or permitted to make any warranty or assume for this company any liability not strictly in accordance with this guarantee. There is no further warranty either expressed or implied beyond that set forth herein.