Dash8-200/300 - Auxiliary Power Unit APU CONTROLS AND INDICATORS. Page 1

Similar documents
Dash8 - Q400 - Pneumatics

Bombardier Challenger Auxiliary Power Unit

Canadair Regional Jet 100/200 - Auxiliary Power Unit

Introduction. APU Location

canaaair chaiiencjer

canadair chzflleriqer OPERATING MANUAL PSP 601A-6 SECTION 5 AUXILIARY POWER UNIT (APU)

SECTION 5 AUXILIARY POWER UNIT (APU) TABLE OF CONTENTS LIST OF ILLUSTRATIONS. Title

ATA 49 AUXILIARY POWER UNIT

DASSAULT AVIATION Proprietary Data

General. APU Control System. APU Door System

CHAPTER 6 ELECTRICAL SYSTEMS

CHAPTER 4 ---AUXILIARY POWER UNIT

GENERAL The Honeywell model TFE731-40AR turbofan engine is a lightweight, two-spool, geared-stage, front-fan, jet engine.

Cessna Citation XLS - Electrical

CHAPTER 4 ---AUXILIARY POWER UNIT

ICE AND RAIN PROTECTION

OVERHEAD PANEL PROCEDURES FLASH CARDS

SECTION IV ELECTRICAL & LIGHTING

B777. Electrical DO NOT USE FOR FLIGHT

CHAPTER ICE AND RAIN PROTECTION SYSTEM

DESCRIPTION AND OPERATION ICE DETECTION SYSTEM

United States Army Aviation Center of Excellence. Fort Rucker, Alabama JULY 2011 STUDENT HANDOUT

AUXILIARY POWER UNIT TABLE OF CONTENTS CHAPTER 5

HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic

LAD Inc. Beechcraft King Air 200 Series Technical Ground School Syllabus Material Covered

GENSET CONTROL MODULE LEVEL 0 A120A. User selectable time delays for engine start and engine stop (cool down).

Surface and Brakes Anti-Ice Systems

GPU Equipment Operating Instructions Table of Contents

24 ELECTRICAL DC ELECTRICAL SYSTEM DESCRIPTION

Canadair Regional Jet 100/200 - Fuel System

Section 13 - E. 1 of 18. Engine Systems

United States Army Warfighting Center Fort Rucker, Alabama OCTOBER 2005

HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic

Cessna Citation XLS - Environmental & Temperature Control

Cessna Citation XLS - Anti-Ice & De-Ice Systems

This chapter contains information on DC Generation, External Power, and Electrical Load Distribution.

DASSAULT AVIATION Proprietary Data

Dornier 328Jet - Pneumatic

canadair chaifenqer 14-CONTENTS Page 1 Feb 12/88 TABLE OF CONTENTS Subject Page GENERAL ICE DETECTION

SECTION III HYDRAULICS & LANDING GEAR

General. Airfoil Anti-Ice System

Bombardier Global Express - Hydraulics

Operation of the FFBH is enabled and disabled by the Automatic Temperature Control Module (ATCM).

AUXILIARY POWER UNIT. Table of Contents. May 06/2005 Flight Crew Operating Manual Volume 2 REV 2 CSP REV 2

AIRCRAFT SYSTEMS FUEL

24-00 ELECTRICAL POWER

B737 NG Anti Ice & Rain

1. AC VOLTS: Displays generator output in voltage. 2. AC FREQUENCY: Displays the speed of the generator set in Hertz.

Examen Teórico sobre Habilitación de Tipo B (Última actualización: Septiembre 2016)

Commander 15i Container and Pallet Loader. Property of American Airlines

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

AIRSTREAM - BATTERY CONTROL CENTER - Diesel

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

PILOT S GUIDE. for the XXX Series Electric Attitude Indicator with Battery Backup

United States Army Warfighting Center Fort Rucker, Alabama NOVEMBER 2006

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER

DEEP SEA ELECTRONICS PLC

AIRCRAFT SYSTEMS PNEUMATIC

DC3Training.com N28AA DC-3 Pilot s Handbook

CHAPTER FUEL SYSTEM

Bombardier Challenger Hydraulic System

GENSET CONTROL MODULE A121H / A241H. User selectable time delays for engine start and engine stop (cool down).

Deep Sea Electronics Plc

GENSET CONTROL MODULE A121A / A241A

ENGEN -100/ENGEN -200 ENGINE GENERATOR CONTROLLER

PA32-RT LANCE II CHECKLIST

XCITE Owner s Manual. Reso-not TM Damping System XCITE 1502C HYDRAULIC POWER SUPPLY

Battery Control Center - Diesel

FUEL CONTROL UNIT ON ALLISON BENDIX 250

FINAL EXAM. 3. Name the items on the control shift in the unmodified aircraft (non ASC-36).

AIRPLANE OPERATIONS MANUAL SECTION 2-15

DASSAULT AVIATION Proprietary Data

ENGINE GROUND RUNNING

DEEP SEA ELECTRONICS PLC

FUEL MODEL 750 BAGGAGE COMPARTMENT SMOKE DETECTION

EXAMEN POR MATERIAS PARA USO DE LOS POSTULANTES A LA HABILITACIÓN DE TIPO EN MATERIAL B733. ENERO 2018

AVANTI P180. Ground Handling

Jump to Table of Contents

Fokker 50 - Ice & Rain Protection. Controls and indicators of the AIRFRAME DE-ICING system are located at the ice protection panel.

Preflight Inspection. Table of Contents. Left Main Landing Gear... 2A-15 Left Fuselage... 2A-16. Left Wing Trailing Edge... 2A-13

PILOT S GUIDE. for the XX Series Electric Attitude Indicator with Battery Backup

A310 AIRCRAFT PREPARATION FOR COLD WEATHER OPERATION FCOM>>Procedure and Techniques >>Inclement Weather Operation

702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS

The Straight Word. Cessna 208 Caravan 208 Caravan I & 208B Grand Caravan Series

GENSET CONTROL MODULE LEVEL 1 A121CM / A241CM. Special logic to re-establish cranking following a false start.

Pneumatic Air Conditioning System Citation, Citation I

Central Warning Systems

The Straight Word. Beechcraft 90 King Air B90 Series. Condition Lever. Set for Takeoff Cabin Altitude Controller Set Cruise Level + 1

ES52 Auto Start Engine Controller Installation and User Manual for the ES52 Auto Start Engine Controller.

AVIATION UNIT AND AVIATION INTERMEDIATE TROUBLESHOOTING MANUAL CH-47D HELICOPTER

Generator Start Control Module

Generator Start Control Module

Standby Power Systems

Rolls -Royce M250--C47M OPERATION AND MAINTENANCE

DASSAULT AVIATION Proprietary Data

AVIATION UNIT AND AVIATION INTERMEDIATE TROUBLESHOOTING MANUAL CH-47D HELICOPTER

Electrical System B-17 Technical Session for Flight Engineers

5220 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL

Troubleshooting Guide

ANALOG CONTROL PANEL

Transcription:

APU CONTROLS AND INDICATORS Page 1

APU control and indicators Page 2

closed APU controls and indicators Page 3

SYSTEM DESCRIPTION General The auxiliary power unit (APU) is a gas turbine engine, located in the rear equipment bay in the aft fuselage. It supplies air and electrical power to the aircraft on the ground. It can be used to assist aircraft engine starts. The APU engine drives a DC starter-generator, which provides 28 VDC to the right main feeder bus. The APU also delivers bleed air for the air-conditioning packs and the airframe de-icing system. An electronic sequence unit (ESU) located on the right side of the rear accessory compartment provides automatic control of automatic start sequencing, running, and other aspects of APU operation. The APU cannot be operated in flight. Weight-off-wheels signals from the PSEU will shutdown the APU if take-off is attempted with the unit operating. The FLR annunciator subsequently illuminates. NOTE: Minimise operation of the APU during ground de-icing operations. Ingestion of glycol-based de-icing fluid may cause damage to the APU. However, certain de-icing procedures at remote positions (no external power unit available) imply engine shutdown before de-icing takes place. To avoid a subsequent battery start, the APU may be used with the BLEED OFF. De-icing personnel should be instructed not to spray any fluid directly into the APU air inlet. Page 4

APU operation Start An APU start requires either the aircraft batteries or external power to be switched ON. The start sequence is initiated by momentarily pressing the START switch light, sending a start signal to the ESU to commence APU start and acceleration. The STARTER segment of the switch light illuminates to indicate the starter is engaged. During the APU spool-up the ESU energizes the APU ignition system and opens the fuel valve at the proper RPM. As the APU accelerates through 70% RPM following light up the ESU disengages the starter (STARTER light goes out), and de-energizes the ignition system. At 90% rpm the ESU configures the APU fuel system for automatic speed governing and arms the bleed air and generator systems for activation. An APU STARTER advisory light remaining illuminated after an APU start, requires the APU NO STARTER CUT OUT emergency checklist to be followed. If the APU fails to start or accelerate, the FLR light on the APU control panel illuminates. Restart is inhibited by a timed relay for two minutes to allow excess fuel to drain. APU starter cranking limits are as follows: START MAX TIME ON FOLLOWED BY 1 1 min. 2 min. off 2 1 min. 2 min. off 3 1 min. 30 min. off The APU PWR switch must be cycled following an automatic shutdown, APU fire detection test or failure to start. Run After a successful start sequence the START light goes out and the RUN segment of the APU PWR switch light illuminates to indicate the APU is ready to deliver bleed air and electrical power. Fuel for APU operation is drawn from the left wing tank collector bay. Shutdown APU normal shutdown is initiated manually at the APU control panel by first off-loading the unit. This is accomplished by first closing the bleed valve by pressing the BL AIR pushbutton. Switch off all DC loads, (except those carried by the battery) and press the GEN pushbutton. The generator ON light goes out and the WRN segment illuminates. Pressing APU PWR on the control panel initiates APU shutdown. Page 5

APU overspeed protection Automatic protection from APU gas generator overspeed is provided by internal, electronic overspeed sensing circuits. When these circuits detect an overspeed, the FLR segment of the APU PWR switch light (along with the APU caution light) illuminates while initiating an immediate APU shutdown sequence. APU fire protection A fully automatic fire detection/extinguishing system (independent from the engine system) is provided for the APU. The system monitors the APU hot section and exhaust. When the detection system senses a fire or overheat condition, (any point of the loop exposed to temperatures above 360-440 F) it illuminates a red FIRE warning light on the APU fire protection panel along with the APU caution light. At the same time an automatic signal commences APU shutdown. Following the detection of a fire/overheat condition and the shutdown of the APU, a relay closes to detonate the discharge cartridge of the fire extinguisher. Detonation of the cartridge ruptures the seal of the discharge valve, releasing the bottle contents. If the APU fire extinguisher does not discharge automatically (BTL light illuminated), the bottle can be discharged manually from the guarded EXTG switch on the APU fire protection panel. NOTE: Once the bottle has been discharged, APU restarting is prevented by interlocking fire protection circuits until the bottle is recharged. Page 6

LEFT WING FUEL COLLECTOR BAY APU fuel schematic Apu bleed system schematic Page 7

LEFT MAIN FEEDER BUS RIGHT MAIN FEEDER BUS LEFT SECONDARY FEEDER BUS RIGHT SECONDARY FEEDER BUS Apu electrical system schematic Page 8

NON-NORMAL INDICATIONS AND OPERATION Caution lights APU Indicates APU fault, APU fire or compartment overheat. Applicable ECL Remarks APU FIRE or APU failure. Also illuminates during overspeed and fire test, and after start sequence when APU generator becomes available. Page 9