Product Catalog EYLANDER ELECTRIC INC.

Similar documents
EYLANDER ELECTRIC INC., WARRANTY DISCLAIMER

Overload Relay Heater Tables

GPH2 Combination Soft Starters

MODEL 2001 HERMETI-CHECK OPERATING INSTRUCTIONS

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

Short-Circuit Current Ratings

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

ECET Circuit Design Motor Loads. Branch Circuits. Article 210

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

Understanding NEMA Motor Nameplates

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

Power electronic brakes

Softstarters. Softstarters Power electronic brakes Type PEB

WELLS RURAL ELECTRIC COMPANY Adopted: March 1976 Revised: March 21, 2017 Reviewed: August 21, 1998 RULE NO. 2

Cutler-Hammer. January 2001

ROTO-CON RONK ELECTRICAL INDUSTRIES, INC. NOKOMIS, IL FIELD INSTALLATION & OPERATION INSTRUCTIONS

Industrial and Commercial Duty IEC Motors

Motor Basics AGSM 325 Motors vs Engines

North America Phase Converters & Electrical Supply

Motors Automation Energy Transmission & Distribution Coatings. GPH2 Combination Soft Starters

Motor Protection. Presented By. Scott Peele PE

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

AG. 225 AGRICULTURAL SYSTEMS/ELECTRICITY AND HYDRAULICS

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

CITY OF WEST PALM BEACH

Motors " GRUNDFOS GROUNDWATER SERVICE MANUAL CONTENTS. Grundfos Motor Specifications... Page 2

SGB12000HX PORTABLE GENERATOR

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

SECTION MOTOR REQUIREMENTS for HVAC

"Motors, Power, and Data Loggers Greg Jourdan-Wenatchee Valley College Tuesday, May 8, Sessions Session 1-8:30-9:25 a.m. Motors 101 Session

The Energy Policy Act. The law s requirements for 1 to 200 horsepower AC motors effective October 24, 1997

SSW07. Soft Starters. Applications. Standard Features

Lift Station Design Standards and Details. Summary of Revisions

DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1...

IMPROVING MOTOR SYSTEM EFFICIENCY WITH HIGH EFFICIENCY BELT DRIVE SYSTEMS

Cutler-Hammer. Molded Case Circuit Breakers Amperes F-Frame. January 2001

EPACT ENERGY POLICY ACT OF 1992: THE SCOPE OF ELECTRIC MOTORS SUBJECT TO EFFICIENCY STANDARDS ON OCTOBER

Cutler-Hammer. Molded Case Circuit Breakers Amperes January J-Frame

WOODWORKING MACHINERY

RS SERIES ROTARY SCREW AIR COMPRESSORS FIXED SPEED ROTARY SCREW AIR COMPRESSORS HP

Cutler-Hammer. Molded Case Circuit Breakers Amperes. -" Product Selection M-Frame

Rotary screw AIR compressors

Definite Purpose Motors. Three Phase, Two Speed, TEFC, Foot Mounted. 3/4 thru 25 Hp NEMA 56 thru 324T

WATTSAVER PREMIUM EFFICIENCY MOTORS GENERAL PURPOSE

Modifiable TITAN Horizontal Motors Accessories and Modifications

Drive Fundamentals. Motor Control Bootcamp May 15-18, Copyright 2015 Rockwell Automation, Inc. All Rights Reserved. PUBLIC CO900H

Corrections most seen on plan review October 18, 2017 David Rankin Seattle Department of Construction and Inspections

Magnetic Overload Relays

AUTO-PUMP 120 VAC AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL. 170 Cherry Avenue West Sayville, NY

5. The force required to bring an object weighing 65 lb from rest to a speed of 50 fps in 10 sec is approximately

AC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave

Motor Protection. Voltage Unbalance & Single-Phasing

[V] Common Control Transformer Control (See page 1-78 Note)

201 S. Anaheim Blvd. Page No Anaheim, CA RULE NO. 2 DESCRIPTION OF SERVICE

FRACTIONAL HORSEPOWER MOTORS & ACCESSORIES

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

a revolution in soft start motor control The future of soft start motor control at your fingertips

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

GUIDE SPECIFICATIONS CE Series Two Stage R-410A

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

The future of soft start motor control at your fingertips

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Cutler-Hammer. Molded Case Circuit Breakers Amperes. Product Selection January 2001 Vol. 1, Ref. No ) J-Frame

SHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

Western Section 101 st Annual Meeting Hot Springs, Arkansas September 21, 2005 Charlie Trout Code Breakfast

TABLE OF CONTENTS INTRODUCTION 3. INSTALLATION PROCEDURES Air Conditioner Location 4. A/C Ducting Installation 5

SPECIFICATIONS & SUBMITTAL DATA

Mill/Drill Conversion to Three Phase and installing a VFD

Is Your Wiring System Safe and Energy Efficient?

MOTORTRONICS Solid State AC Motor Control

Comfort. Productivity Through. Industrial Coolers. Maximum Efficiency Evaporative Air Cooling. 12 Wet Section Series

PATTERSON PUMP COMPANY

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

HIGH PRESSURE AIR COMPRESSOR SYSTEM MODEL #: 091-9HP-220 INPUT:

Comfort. Productivity Through. Industrial Coolers. High Efficiency Evaporative Air Cooling. 8 Wet Section Series

a revolution in soft start motor control The future of soft start motor control at your fingertips

WARRANTY INFORMATION...

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

Pretest Module 21 Units 1-4 AC Generators & Three-Phase Motors

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

Overvoltage Suppression F7 Drive Software Technical Manual

TABLE OF CONTENTS CHAPTER 1 ELECTRICAL THEORY About This Textbook...xi. Passing Your Exam...xiv. How to Use the National Electrical Code...

Power Connect TM Series RX60

SECTION COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT

Leeson Single Phase Electric Motor characteristics and applications

Instruction Sheet for Powertite Plug, Connector and Receptacle

56 FRAME & 56C FRAME FRACTIONAL MOTORS From WorldWide Electric

AND LOAD PARAMETERS IMPORTANT MOTOR. Torque x Speed Constant. Horsepower= Mechanical Power Rating Expressed in either horsepower or watts

Pump ED 101. Power Factor (Part 2) - - Electricity Behaving Better

TABLE OF CONTENTS INTRODUCTION.. 3. A/C Ducting Installation. Power Kit Installation (Batteries)...5 OPERATION MANUAL 7-8 TOOLS LIST..

Arktite Heavy Duty Circuit Breaking Plugs and Connectors

Spark-ignited generator set

SUBMERSIBLES INDEX. General Description and Notes UL Motors Single-Phase UL Approved Three-Phase UL Approved... 4

Static Phase Converters Rotary Phase Converters Double-Throw Switches Fused Disconnect Double-Throw Switches Non-Fused Disconnect Switches Stray

Motor Protection. Voltage Unbalance & Single-Phasing

Electric Motor Controls BOMA Pre-Quiz

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

C E R T I F I C A T E O F C O M P L I A N C E

Transcription:

Product Catalog EYLANDER ELECTRIC INC.

Page 2 To Order Call: 1-800-932-8986 BEFORE YOU CALL THERE ARE TEN THINGS TO KNOW FOR SIZING A PHASE CONVERTER THEY ARE: What is the available single phase voltage? How many amps of single phase is available? What is the nameplate voltage(s) on the motors? What kind of machine is the motor(s) driving? (compressor, refrigeration, lathe, welder, etc.) How is the work done on each machine? (Such as on a metal shear, is it hydraulic or flywheel?) What is the total horsepower of all the motors to be run at the same time? What is the total horsepower of all the motors that start at the same time? Are the motors Import or Domestic in origin? What is the age(s) of the motors. Are there any computers on the machine(s)?

Eylander Electric Inc. Page 3 TABLE OF CONTENTS BEFORE CALLING 2 PHASE SPLITTER S MODELS 4 SPD MODELS 6 SB MODELS 8 PHASE ADDER RS MODELS 10 RSB MODELS 12 RC MODELS 14

Page 4 To Order Call: 1-800-932-8986 PHASE SPLITTER SOLID STATE OR STATIC PHASE CONVERTERS NOT RECOMMENDED TO BE USED ON MOTORS BUILT AFTER 1995* A static phase converter is one that externally changes a three phase motor to a capacitor-start, capacitor-run single phase motor; running at approximately the same amperage as a single phase motor of the same horsepower. The single phase amp draw of a three phase motor on our Phase Splitter is 1 1/2 times the three phase nameplate amps. Since the motor will only produce 80 percent continuous duty, the overload heaters should not exceed 125 percent of the full load three phase amps of the motor to which it is connected if the heaters and magnetic starter are installed ahead of the Phase Splitter. Example 5 hp, three phase, 240 volt motor draw 15 amps Multiply the amperage by 125 percent 18.75 amps Result Use 18.75 amp heaters in the motor starter, ahead of the static phase splitter. You can also install the Splitter itself ahead of the magnetic starter and motor. In this case you would size your heaters to match the 3-phase FLA of the motor since the overload protection device would be sensing on the 3-phase side of the converter rather than only through 2 poles on the single phase side. *PLEASE NOTE: All general use motors manufactured after October of 1997 and some motors before, are EPAct rated according to the Energy Policy Act of 1992 for efficiency standards mandated by the U.S. Government. With these load motors, it is not recommended to run them on a static phase converter. They should be run on a rotary converter. Unfortunately, it is not clear on the nameplate of the motor whether it is EPAct rated. If you think the motor is manufactured after 1995, then we recommend a rotary converter.

Eylander Electric Inc. Page 5 TYPICAL WIRING DIAGRAMS AND GENERAL INFORMATION FOR PHASE SPLITTER S Models BOX DIMENSIONS VARY. STARTING SIZE IS 8X8X4 AND GO UP TO 12X18X6 FOR LARGER UNITS. All Eylander Electric Phase Converters are UL Listed. LIGHT HP DUTY: is intended for motors that run idle empty until the load is applied. This includes RADIAL ARM SAWS, CUT OFF SAWS, LIGHT DUTY LATHES, etc. CAT # IN OUT S-1/2 3 2 S-3/4 4.2 2.8 S-1 6 3.6 S-1 1/2 8 5.2 S-2 11 6.8 S-3 18 9.6 S-5 30 15.2 S-7 1/2 42 22 S-10 53 28

Page 6 To Order Call: 1-800-932-8986 PHASE SPLITTER SOLID STATE OR STATIC PHASE CONVERTERS NOT RECOMMENDED TO BE USED ON MOTORS BUILT AFTER 1995* For Air Compressors, Heat Pumps and Refrigeration Equipment, they work very well if the pulley size on the motor of the compressors is reduced by 25% to get satisfactory long life out of the motor. THESE PHASE SPLITTERS ARE NOT INTENDED TO TAKE THE PLACE OF THE PHASE ADDER ROTARY PHASE CONVERTERS. THEY ARE NOT TO BE USED ON DEEP WELL PUMPS, TWO SPEED MOTORS, HYDRAULIC PRESS UNITS, HARD STARTING LATHES, MACHINERY THAT REQUIRES INSTANT REVERSE OR ANY OTHER THREE-PHASE EQUIPMENT THAT REQUIRES A HEAVY STARTING, HEAVY DUTY RUNNING LOAD. See our listing of the 'PHASE ADDER' rotary converters. They are the best on the market when you size them according to our directions. *PLEASE NOTE: All general use motors manufactured after October of 1997 and some motors before, are EPAct rated according to the Energy Policy Act of 1992 for efficiency standards mandated by the U.S. Government. With these load motors, it is not recommended to run them on a static phase converter. They should be run on a rotary converter. Unfortunately, it is not clear on the nameplate of the motor whether it is EPAct rated. If you think the motor is manufactured after 1995, then we recommend a rotary converter.

Eylander Electric Inc. Page 7 TYPICAL WIRING DIAGRAMS AND GENERAL INFORMATION FOR PHASE SPLITTER SPD Models BOX DIMENSIONS VARY. STARTING SIZE IS 8X8X4 AND GO UP TO 12X18X6 FOR LARGER UNITS. All Eylander Electric Phase Converters are UL Listed. USED FOR COMPRESSORS AND ABOVE GROUND PUMPS. CAT # IN OUT SPD-2 20 6.8 SPD-3 20 9.6 SPD-5 40 15.2 SPD-7 1/2 60 22 SPD-10 70 28 SPD-15 100 42 SPD-20 100 54 SPD-25 130 68 SPD-30 150 80

Page 8 To Order Call: 1-800-932-8986 PHASE SPLITTER SOLID STATE OR STATIC PHASE CONVERTERS NOT RECOMMENDED TO BE USED ON MOTORS BUILT AFTER 1995* These units are the same as the S style but with overload protection built in. A static phase converter is one that externally changes a three phase motor to a capacitor-start, capacitor-run single phase motor; running at approximately the same amperage as a single phase motor of the same horsepower. The single phase amp draw of a three phase motor on our Phase Splitter is 1 1/2 times the three phase nameplate amps. Since the motor will only produce 80 percent continuous duty, the overload heaters should not exceed 125 percent of the full load three phase amps of the motor to which it is connected if the heaters and magnetic starter are installed ahead of the Phase Splitter. Example 5 hp, three phase, 240 volt motor draw 15 amps Multiply the amperage by 125 percent 18.75 amps Result Use 18.75 amp heaters in the motor starter, ahead of the static phase splitter. You can also install the Splitter itself ahead of the magnetic starter and motor. In this case you would size your heaters to match the 3-phase FLA of the motor since the overload protection device would be sensing on the 3-phase side of the converter rather than only through 2 poles on the single phase side. *PLEASE NOTE: All general use motors manufactured after October of 1997 and some motors before, are EPAct rated according to the Energy Policy Act of 1992 for efficiency standards mandated by the U.S. Government. With these load motors, it is not recommended to run them on a static phase converter. They should be run on a rotary converter. Unfortunately, it is not clear on the nameplate of the motor whether it is EPAct rated. If you think the motor is manufactured after 1995, then we recommend a rotary converter.

Eylander Electric Inc. Page 9 TYPICAL WIRING DIAGRAMS AND GENERAL INFORMATION FOR PHASE SPLITTER SB Models BOX DIMENSIONS VARY. STARTING SIZE IS 16X24X4 AND GO UP TO 16X32X6 FOR LARGER UNITS. All Eylander Electric Phase Converters are UL Listed. LIGHT HP DUTY: is intended for motors that run idle empty until the load is applied. This includes RADIAL ARM SAWS, CUT OFF SAWS, LIGHT DUTY LATHES, etc. CAT # IN OUT SB-1 1/2 15 5.2 SB-2 15 6.8 SB-3 20 9.6 SB-5 40 15.2 SB-7 1/2 60 22 SB-10 100 28 SB-15 100 42 SB-20 100 54

Page 10 To Order Call: 1-800-932-8986 PHASE ADDER ROTARY PHASE CONVERTERS A versatile Phase converter. Our rotary Phase Converters have been tested and designed to fit your needs. Once unpacked and setup instructions have been read, it is possible to have three phase power in an hour. RS Models are the basic model. They are intended for use with one-load-only applications. Your situation may require you to install an external disconnect.

Eylander Electric Inc. Page 11 TYPICAL WIRING DIAGRAMS AND GENERAL INFORMATION FOR PHASE ADDER RS Models BOX DIMENSIONS VARY. STARTING SIZE IS 16X16X4 AND GO UP TO 16X38X6 FOR LARGER UNITS. All Eylander Electric Phase Converters are: UL Listed. Max Amps are based upon a light duty start and light duty run motor. To figure in a regular duty motor multiply by.75. To figure in a heavy duty motor multiply by.75 a second time. Example: RS25=80 Amps max, light duty 80 X.75 = 60 Amps max, regular duty 60 X.75 = 45 Amps max, heavy duty Based upon those numbers a 7 1/2 hp HD is the largest motor that can be ran. CAT # MAX IN MAX OUT RS-3 40 20 RS-5 50 30 RS-7 1/2 60 40 RS-10 100 60 RS-15 125 60 RS-20 125 60 RS-25 125 80

Page 12 To Order Call: 1-800-932-8986 PHASE ADDER ROTARY PHASE CONVERTERS The most versatile of all Phase Converters. Our rotary Phase Converters have been tested and designed to fit your needs. Once unpacked and setup instructions have been read, it is possible to have three phase power in an hour. RSB Models are the upgrade from the RS model. They are intended for use with multiple-load applications. These units are Service Entrance rated. As you can see they come with a load center, so once up and running it can be treated as a three phase panel.

Eylander Electric Inc. Page 13 TYPICAL WIRING DIAGRAMS AND GENERAL INFORMATION FOR PHASE ADDER RSB Models BOX DIMENSIONS VARY. STARTING SIZE IS 16X24X4 AND GO UP TO 16X60X8 FOR LARGER UNITS. All Eylander Electric Phase Converters are: UL Listed. CAT # MAX IN MAX OUT RSB518-60-3/5 60 30 RSB-718-60-3/5 60 40 RSB-1018-100-5/7 100 60 RSB-1518-125-5/7 125 60 RSB-2018-125-5/7 125 60 RSB-2518-125/200-6/8 125/200 60/80 RSB-3018-200-8/10 200 100 RSB-4018-200-10 200 100 RSB-5018-225-10 225 125 Max Amps are based upon a light duty start and light duty run motor. To figure in a regular duty motor multiply by.75. To figure in a heavy duty motor multiply by.75 a second time. Example: RSB25=80 Amps max, light duty 80 X.75 = 60 Amps max, regular duty 60 X.75 = 45 Amps max, heavy duty Based upon those numbers a 7 1/2 hp HD is the largest motor that can be ran.

Page 14 To Order Call: 1-800-932-8986 PHASE ADDER ROTARY PHASE CONVERTERS The fully automatic Phase Converters. Our rotary Phase Converters have been tested and designed to fit your needs. Once unpacked and setup instructions have been read, it is possible to have three phase power in an hour. RC Models are the upgrade from the RS model. They are intended for use with one-load applications. These units work best with elevators and pumps, or places that manually turning the unit on, would be difficult. These units can be built to supply power to a 50hp Heavy Duty motors. Plus can be built to supply 480v loads. Soft Start Models are also available.

Eylander Electric Inc. Page 15 TYPICAL WIRING DIAGRAMS AND GENERAL INFORMATION FOR PHASE ADDER RC Models BOX DIMENSIONS VARY. STARTING SIZE IS 24X24X6 AND GO UP TO 60X60X12 FOR LARGER UNITS. All Eylander Electric Phase Converters are: UL Listed. CAT # MAX IN MAX OUT RC-518 50 30 RC-718 60 40 RC-1018 100 60 RC-1518 125 60 RC-2018 200 60 RC-2518 200 80 RC-3018 225 100 RC-4018 225 100 RC-5018 225 125 RC-6018 225 150 Max Amps are based upon a light duty start and light duty run motor. To figure in a regular duty motor multiply by.75. To figure in a heavy duty motor multiply by.75 a second time. Example: RC25=80 Amps max, light duty 80 X.75 = 60 Amps max, regular duty 60 X.75 = 45 Amps max, heavy duty Based upon those numbers a 7 1/2 hp HD is the largest motor that can be ran.

EYLANDER ELECTRIC INC. 3601 Everett AVE Everett, WA 98201