ULTRASONIC FLOWMETER < >

Similar documents
SERIES ULTRASONIC FLOWMETER

ULTRASONIC FLOWMETER <

Applicable pipe diameter is 13mm to 6000mm

SERIES ULTRASONIC FLOWMETER

ULTRASONIC FLOWMETER < >

ULTRASONIC FLOWMETER TIME DELTA-C

PORTABLE TYPE ULTRASONIC FLOWMETER

ULTRASONIC FLOWMETER < S (Standard Type)> DATA SHEET

PORTABLE TYPE ULTRASONIC FLOWMETER

Time Delta S Fixed Transit-Time Flow Meter System

FEATURES SPECIFICATIONS FSV-2, FSS, FLY SERIES ULTRASONIC FLOWMETER < > DATA SHEET. Operational specifications. EDSX6-142b. Flow transmitter (FSV S)

UL350 ULTRASONIC FLOWMETER CLAMP-ON TYPE OUTLINE FEATURES MEASUREMENT PRINCIPLE

ULTRASONIC FLOWMETER M-Flow

Ultrasonic Flowmeters

Instruction Manual ULTRASONIC FLOWMETER TYPE: UXF1 SX1, PSX2 ULTRASONIC FLOW METER. Dwyer Instruments, Inc. Bulletin F-69

PORTABLE TYPE ULTRASONIC FLOWMETER (PORTAFLOW-C)

UL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES STANDARD SPECIFICATION. Common specification

Ultrasonic Flowmeters

FLOW METER ULTRASONIC-VOLTEX FLOW METER ASUSV SERIES IMPELLER FLOW METER ASIP80 SERIES IMPELLER FLOW METER ASSPX SERIES

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

Portable Ultrasonic Flow Measuring System prosonic flow 92

Portable Transit Time Flow Meter for Accurate Flow Measurement from Outside a Pipe

CDT1000 series QUICK FLOW. Digital Flowmeter for Air Conditioning Application OUTLINE FEATURES STANDARD SPECIFICATION

UL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES MEASURING PRINCIPLE

Range of Ultrasonic Flowmeters.

NCM-603 Hand Held Clamp-on Ultrasonic Transit Time Flowmeter

SS Concentration Analyzer

SRT1000 Series THERMAL FLOWMETER

Flow Measurement SITRANS F S Clamp-on

2-Color Display Digital Flow Switch

EASZ-10P Operating Instructions

Ultrasonic Flowmeter. M-1500 Plus Non-invasive Inline DSP Ultrasonic Flowmeter. Operating Principle. Features

Online data sheet FLOWSIC100 VOLUME FLOW MEASURING DEVICES

The Multivariable Air Flow Meter

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

The Multivariable Air Flow Meter

DYNAMETERS SERIES DMTF ULTRASONIC FLOW METER

Related vacuum products

Fuji Instrumentation & Control. Flowmeter. Series ECNO:620

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement

mass flowmeter for compressed air

INDEX. Introduction. Introduction. Sensor Mounting. Keypad System. Battery. Menu System. Error/Warning Messages. Troubleshooting guide

UTM10 Series Ultrasonic Transit-time Flowmeters

TRANSIT TIME FLOW METERS

Flow Measurement. SITRANS F US Clamp-on. SITRANS FUP1010 (Portable) 4/318 Siemens FI Overview

FLOWX3 F3.60M.S Insertion Magmeter

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

ULTRAFLO 2000 ULTRASONIC LIQUID FLOW AND HEAT/ENERGY METERS FOR PERMANENT INSTALLATION HIGH TEMPERATURE SENSORS AS STANDARD

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

Liquid Turbine Flow Meter OwnerÊs Manual

1000 Series MASSMAX. Coriolis Mass Flowmeter Straight Twin Tube OUTLINE FEATURES STANDARD SPECIFICATIONS. Fluid Specifications

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

Zirconia Oxygen Gas Analyzers

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters

Appendix. Clearance. Skewed profiles. Application Schematics

PG-30 PRESSURE GAUGES P G R - N MODEL NUMBER DESIGNATION

FPI-X FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODEL 395X MAG METER SUBMITTAL

Inline Ultrasonic Flowmeter

Dissolved Oxygen Measurement System with Air Blast Cleaner

F-2600 SERIES INLINE VORTEX FLOW METER

Paddle-wheel flow controller for On/Off control

Ultrasonic Sludge Blanket Monitoring System

PG-30 PRESSURE GAUGES P G R - N FEATURES MODEL NUMBER DESIGNATION

F-2700 SERIES INSERTION VORTEX FLOW METER

Model DFX Doppler ultrasonic flow meter

Three types of flow range. 0.4 to 4 L/min (PF2D504) 1.8 to 20 L/min (PF2D520) 4.0 to 40 L/min (PF2D540) Swept flow characteristics (reference)

VORTEX IN-LINE FLOW METERS

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Paddle-wheel flow controller for On/Off control

ULTRASONIC FLOWMETER / HEATMETER

Micro Motion T-Series Straight-Tube Mass Flow and Density Meters. Product Data Sheet PS July 2001

Ultrasonic Sludge Blanket Monitoring System

Vortex In Line Flow Meter

Flow Measurement SITRANS F US Clamp-on

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

Model TUR-200D Turbine Flowmeter

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series

Ultrasonic Flow Meter Series Smart-IN US. Features. Description

CDT1000 Series QUICK FLOW. Digital Flowmeter for Air Conditioning Application OUTLINE FEATURES STANDARD SPECIFICATION

Full Profile Insertion

To avoid injury, death of personnel ordamage to instrument, the operator must refer to an explanation in the User smanual.

JUMO ecotrans Lf 01/02

3-colour / 2-screen display

Turbidity and Suspended Solids Transmitter

better measurement Simply a question of

SERIES 454FTB-WGF TECHNICAL SPECIFICATIONS

Ultrasonic filling level sensor UFM 200 / 600 C2 / C4 / R / MD

IN-SITU ZIRCONIA OXYGEN ANALYZER

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control. Benefits.

HENRI Flowmeter for Pulp Slurry

3 -color/2-screen display

FPI Mag FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODELS 394L AND 395L MAG METER SUBMITTAL

F-1500 SERIES INSERTION TURBINE FLOW METER

ph Analyzer (4-wire system transmitter) ORP Analyzer (4-wire system transmitter)

3 -color/2-screen display

F-2700 SERIES INSERTION VORTEX FLOW METER

Transcription:

SERIES ULTRSONIC FLOWMETER < > DT SHEET FS, FLS/FLW/FLD This flowmeter is a clamp-on type ultrasonic flow meter based on transit-time measuring method. Making full use of the latest electronics and digital signal processing technologies, we realized a compact and lightweight design, and improved the accuracy and easiness to use while keeping with anti-bubble performance. The communication function (MODBUS: Option) is also applicable. FETURES 1. Compact and light-weight Thanks to the adoption of the latest electronics and digital signal processing technologies, the flow transmitter size and mass are 1/3 of our traditional instrument. 2. Full variety of sensors The flowmeter can be used with various types of sensors applicable for wide range of pipe size (ø13 to ø6000mm) and fluid temperature (-40 to +200 C). 3. High accuracy The flowmeter is designed for high accurary (better than ±1.0% of rate) by dynamic correction of fully-developed flow profile. Reynolds Number is calculated and a meter factor (K) is automatically applied for best accuracy at all flow velocities. Further, the adoption of new sound velocity measurement system permits measurements of fluids of unknown sound velocity. Moreover, affection from fluid temperature and pressure is negligible (uto- Temp./Press. compensation). 4. Excellent resistance against aerated flow Fuji's unique BM feature improves measurement reliability for different flow like slurries, sludge, raw sewage and bubble-contained flow (acceptable up to air bubble of 12% volume at 1m/s velocity). 5. Quick response With the use of high-speed micro-processor suited for digital signal processing, the fast response time is realized. 6. Multi-lingual The following languages are supported for display: Japanese (Katakana), English, German French, and Spanish. 7. Excellent performance and easy operation LCD and function keys are allowing easy configuration and trouble shooting. LCD with back light Easy mounting of sensor Trouble shooting Easy operation with keypad on outer surface of flow transmitter housing. SPECIFICTIONS Flow Transmitter (FS) (FLW) Operational specifications (FLD32) (FLSE12) (FLSE22) System configuration: Single-path system of a flow transmitter (Model FS) and a detector (Model FLS/FLW/FLD) pplicable fluid: Homogenous liquid where the ultrasonic signal can be transmitted Bubble quantity: 0 to 12vol% (for pipe size 50, water, velocity 1m/s) Fluid turbidity: 10000mg/L max. Type of flow: Fully-developed turbulent or laminar flow in a full-filled pipe Flow velocity range: 0 to ±0.3... ±32m/s Power supply: 100 to 240 C +10%/-15%, 50/60Hz; or 20 to 30 DC Signal cable (between detector and converter): Coaxial cable (5m standard, 300m (60m for popular detector (FLS)) max.) Heat resistance: 80 C EDSX6-133b Date Oct. 15, 2007

FS, FLS/FLW/FLD Installation environment: Non-explosive area without direct sunlight, corrosive gas and heat radiation. mbient temperature: Flow transmitter: -20 to +55 C : -20 to +60 C -20 to +80 C (for FLSS 2 2- only) mbient humidity: 95%RH max. Grounding: Class D (100 Ω) rrester: Provided as standard at output and power supply pplicable piping and fluid temperature: Popular type Common type FLD22 FLW1 Pipe size (inner diameter) pplicable pipe material Mounting method ø25 to ø100 mm Plastic (PC, etc.) (Note 1) FLSE12 Metal pipe (SS, steel pipe, ø50 to ø100 mm copper pipe, aluminum pipe, etc.) (Note 2) method Plastic (PC, etc.) (Note 1) Metal pipe (SS, steel pipe, FLSE22 ø50 to ø225 mm copper pipe, aluminum pipe, etc.) (Note 2) FLW4 FLW5 ø13 to ø100 mm ø50 to ø400 mm ø200 to ø1200 mm ø200 to ø6000 mm Plastic (PC, etc.) (Note 1) Metal pipe (SS, steel pipe, copper pipe, aluminum pipe, etc.) (Note 2) Fluid temperature range (Note 3) 9th digit in code symbol... -20 to +100 C... 0 to +120 C (Note 4) Heat shock resistance 150 C, 30min method -40 to 100 C or Z method -40 to 80 C FLD32 ø50 to ø400 mm -40 to 200 C Note 1: If the pipe material is PP or PDF, select FLW11, FLW41 or FLW5. Note that the wall thickness is 15mm or less for PP, and 9mm or less for PDF. Note 2: For cast iron pipe, lining pipe, old steel pipe or others through which the ultrasonic signal could not be transmitted easily, select FLW11, FLW41 or FLW50. Lining material: Tar epoxy, mortar, rubber, etc. * In case the lining is not glued to a pipe, the measurement may be impossible. Straight pipe length: Typically 10D for upstream and 5D for dowstream. (D: Pipe inner diameter) Refer to conditions on straight pipe for details (Japan Electric Measuring Instruments Manufacturers' ssociation Standard JEMIS-032). Note 3: If silicone-free grease is used as acoustic coupler, the fluid temperature range is 0 to 60 C regardless of the detector. Note 4: When the 9th digit in the code symbol is, the applicable piping diameter is up to 150mm. Performance specifications Rated accuracy: Popular type Common type Pipe size (diameter) ø25 to ø50 mm FLSE12 ø50 to ø100 mm ø50 to ø100 mm ø50 to ø225 mm FLSE22 ø50 to ø225 mm FLD22 FLW12 FLD32 FLW51 FLW11 FLW41 FLW50 ø13 to ø50 mm ø50 to ø100 mm ø50 to below ø300 ø300 to ø6000 mm ø50 to below ø300 ø300 to ø6000 mm pplicable pipe material Plastic Metal pipe Plastic Metal pipe Plastic, metal pipe Flow velocity ccuracy 2 to 32m/s ±2.0% of rate 0 to 2m/s ±0.04m/s 2 to 32m/s ±1.0% of rate 0 to 2m/s ±0.02m/s 2 to 32m/s ±2.0% of rate 0 to 2m/s ±0.04m/s 2 to 32m/s 0 to 2m/s 2 to 32m/s ±1.0% of rate ±0.02m/s ±2.0% of rate 0 to 2m/s ±0.04m/s 2 to 32m/s 0 to 2m/s 2 to 32m/s ±2.5% of rate ±0.05m/s ±1.5% of rate 0 to 2m/s ±0.03m/s 2 to 32m/s ±1.0% of rate 0 to 2m/s ±0.02m/s 1 to 32m/s ±1.0% of rate 0 to 1m/s ±0.01m/s 2 to 32m/s ±1.5% of rate 0 to 2m/s ±0.03m/s 1 to 32m/s ±1.5% of rate 0 to 1m/s ±0.015m/s Response time: 0.5s (standard mode) 0.2s as selected (quick response mode) Power consumption: 15 max. (C power supply) 6W max. (DC power supply) Functional specifications nalog signal: 4 to 20m DC (1 point) Load resistance: 1 kω max. Digital output: Forward total, reverse total, alarm, acting range, flow switch, total switch assignable arbitrarily (1) Mechanical relay contact (isolated, socket provided, arrester incorporated) Output: 1 point Normal: Open/Close selectable Contact capacity: 240 C, 30 DC, 1 Output frequency: 1P/s max. (pulse width: 50, 100, 200ms) (2) Transistor contact (isolated, open collector, arrester incorporated) Outputs: 2 points Normal: ON/OFF selectable Contact capacity: 30 DC, 0.1 Output frequency: 1000P/s max. (pulse width: 5, 10, 50, 100, 200ms) Digital input: 1 point (no-voltage contact) (option)/ Set zero, Preset total assignable Serial communication (option): RS-232C equivalent or RS-485, isolated, arrester incorporated Connectable quantity: 1 unit (RS-232C)/up to 31 units (RS-485: MODBUS) Baud rate: 9600, 19200, 38400bps Parity: /Odd/Even selectable Stop bits: 1 or 2 bits selectable 2

Cable length: 15m max. (RS-232C)/1km max. (RS-485) Data: Flow velocity, flow rate, forward total, reverse total, status, etc. Display device: 2-color LED (Normal: green, Extraordinary: red) LCD with 2 lines of 16 characters and back light Indication language: Japanese (Katakana)/English/French/ German/Spanish (changeable) Flow velocity/flow rate indication: Instantaneous flow velocity, instantaneous flow rate indication (minus indication for reverse flow) Numerals: 8 digits (decimal point is counted as 1 digit) Unit: Metric/Inch system selectable Metric system Inch system elocity m/s ft/s Flow rate L/s, L/min, L/h, L/d, kl/d, ML/d, m 3 /s, m 3 /min, m 3 /d, km 3 /d, Mm 3 /d, BBL/s, BBL/ min, BBL/h, BBL/d, kbbl/d, MBBL/d Note: The gal means USgal. gal/s, gal/min, gal/h, gal/d, kgal/d, Mgal/d, ft 3 /s, ft 3 /min, ft 3 /d, Kft 3 /d, Mft 3 /d, BBL/s, BBL/min, BBL/h, BBL/d, kbbl/d, MBBL/d Total indication: Forward or reverse total value indication (negative indication for reverse direction) Numerals: 8 digits (decimal point is counted as 1 digit) Unit: Metric/Inch system selectable Metric system Inch system Total ml, L, m 3, km 3, Mm 3, mbbl, BBL, KBBL gal, kgal, ft 3, kft 3, Mft 3, mbbl, BBL, kbbl, CRE-ft Configuration: Fully configurable from the 4-key pad (ESC,,, ENT) on the surface of flow transmitter s housing case by menu-driven software Zero adjustment: Set zero/clear available External zero adjustment: Set zero available upon digital input setting Damping: 0 to 100s (every 0.1s) for analog output and flow velocity/flow rate indication Low flow rate cutoff: 0 to 5m/s in terms of flow velocity larm: Digital output available for Hardware fault or Process fault Burnout: nalog output: Hold/Overscale/Underscale/Zero selectable Flow rate total: Hold/Count selectable Burnout timer: 0 to 100s (every 1s) Bi-directional range: Forward and reverse ranges configurable independently. Hysteresis: 0 to 10% of working range Working range applicable to digital output uto-2 range: 2 forward ranges configurable independently Hysteresis: 0 to 10% of working range Working range applicable to digital output Flow switch: Lower limit, upper limit configurable independently Digital output available for status at actuated point Total switch: Forward total switching point configurable Digital output available when actuated External total preset: Preset total settable upon contact input setting Physical specifications Type of enclosure: Flow transmitter: IP66 : FLS (popular type): IP65 (When waterproot BNC connector is provided) FLW (common type): IP67 (When the terminal block is filled with silicon rubber after wiring) FLW (submersible type): IP68 FLD (small diameter and high temperature type): IP52 Mounting method: Flow transmitter: Mounted on wall or by 2B pipe : Clamped on pipe surface coustic coupler: Silicone rubber, silicone grease or siliconefree grease Note: The acoustic coupler is a medium that eliminates a gap between detector and pipe Type of acoustic coupler: Type Fluid temperature Teflon piping Silicone rubber (KE-348W) -40 to +150 C Silicone grease (G40M) -30 to +150 C Silicone-free grease (HIGH Z) 0 to +60 C Grease for high temperature (KS62M) -30 to +250 C In case of Teflon piping, use grease. Procure silicone grease (G40M), if necessary, as an optional accessory. Material: Flow transmitter: luminum alloy : Sensor housing Sensor cover Guide rail FLSE1 PBT SUS304 FLSE2 PBT SUS304 FLD22 PBT luminum alloy + plastic FLW1 PBT SUS304 SUS304 + plastic FLW4 FLW5 FLD32 PBT SUS304 SUS304 SUS304 + aluminum alloy 3

FS, FLS/FLW/FLD Signal cable: Dimensions: Mass: FL3 (applicable detector: FLS) Structure: Heat-resisting high-frequency coaxial cable (3D2) Sheath: Flame-resisting PC Outer diameter: ø5mm Termination: M3 amp terminal (flow transmitter side) and BNC connector (sensor side) FL8, FL9 (applicable detector: FLW, FLD) Structure: High frequency coaxial cable (double shield) Sheath: Black flame-resisting PC Outer diameter: ø7.5mm Termination: M3 amp terminal (flow transmitter side) and M4 amp terminal. Note, however, that the detecter side of FLD22 and FLD32 is provided with BNC connector (FL9). Mass: pprox. 90g/m Flow transmitter: H170 W142 D70mm : H50 W228 D34mm (FLSE1) H50 W348 D34mm (FLSE2) H90 W300 D53mm (FLD22) H40 W500 D80mm (FLW1) H40 W72 D60mm (FLW4) H62 W104 D93mm (FLW5) H205 W530 D52mm (FLD32) Flow transmitter: 1.5kg : 0.3kg (FLSE1) 0.4kg (FLSE2) 0.6kg (FLD22) 1.0kg (FLW1) 0.4kg (FLW4) 1.4kg (FLW5) 1.6kg (FLD32) Loader software Provided as standard Compatible model is PC/T compatible instrument. Operation is undefined for PC98 series (NEC). Main functions: Software for Main unit parameter setting/change on PC OS: Windows 2000/XP Memory requirement: 125MB min. Disk unit: CD-ROM drive compatible with Windows 2000/ XP Hard disk capacity: Minimum vacant capacity of 52MB or more Note: Loader cable (Model ZZP*TK4J1236) is additionally necessary. Note: USB-RS232C converter For PC that does not support RS-232C serial interface, a converter is necessary for connecting the PC and main unit. USB-RS232C converter should be combined with the above loader cable. <Recommendation> USB-CRS9 (manufactured by Sanwa Supply) 4

MESURING PRINCIPLE With ultrasonic pulses propagated diagonally between the upstream and downstream sensors, flow rate is measured by detecting the time difference obtained by the flow of fluid. CONFIGURTION DIGRM (1) Single-path system ( method) Cable Upstream sensor θ Output signal t D 2 Flow velocity t 1 Flow transmitter Flow transmitter DC 4 to 20m Digital signal (Up to 2 point) Downstream sensor (2) Single path system (Z method) Cable MOUNTING OF DETECTOR Ultra sonic oscillator Plastic wedge Pipe Flow transmitter DC 4 to 20m Digital signal (Up to 2 point) Lining DETECTOR SELECTION GUIDE Type FLSE12 2- FLSE12 2- FLSE22 2- FLSE22 2- Fluid Mounting temperature [ C] method -20 to 100 0 to 120-20 to 100 0 to 120 Inner diameter of piping ø (mm) 13 25 50 100 200 250 300 400 1000 3000 6000 25 P 100 50 M 100 50 P, M 50 P, M 150 225 FLW12 Note) FLW11 50 Px, P, M 300 FLW41-40 to 80 Z 200 Px, P, M 600 200 Px, P, M 1200 FLW51 Note) FLW50 Z 200 Px, P, M 3000 200 Px, P, M 6000 FLD22-40 to 100 13 Px, P, M 100 FLD32-40 to 200 Z 50 Px, P, M 250 150 Px, P, M 400 Classification of piping materials Px : PP, PDF P : Plastic (PC, etc.) M : Msetallic piping (steel pipe, copper pipe, aluminum, etc.) Note: The ultrasonic signal cannot be transmitted easily when the classification of piping material is Px or the turbidity is high. In such a case, a preliminary check by a portable ultrasonic flowmeter is recommended. 5

FS, FLS/FLW/FLD CODE SMBOL <Flow transmitter> 1 2 3 4 5 6 7 8 9 10 11 12 13 14 FS 1 S Description E B 1 4 S B C B N E (Destination) (4th digit) Standard (English) (Communication) (5th digit) RS232C+DI RS485+DI (Use) (6th digit) Single measuring path (Power supply) (7th digit) C100 to 240 50/60Hz DC20 to 30 (Case structure) (9th digit) Standard (IP66) (Wire connection port) (10th digit) Weatherproof gland provided [G1/2 and G3/8 (internal threads)] (Combination with explosion-proof detector) (11th digit) (Parameter setting) (12th digit) Setting provided Setting provided + tag Tag (Mounting method) (13th digit) Pipe mount Wall mount (rea) (14th digit) merica Europe, Middle East, frica sia <, small diameter/high temperature type> 1 2 3 4 5 6 7 8 9 F LD 1 Description Type (4th, 5th and 6th digits) 2 2 0 Small diameter sensor (ø13 to ø100), method 3 2 0 High-temperature sensor *1 (ø50 to ø400), or Z method Belt, acoustic coupler (7th digit) S For fixed type Coaxial cable (9th digit) *1: For turbid fluid or old pipe, cast iron pipe, mortar lining pipe or others through which the ultrasonic signal could not be transmitted easily, use an optional guide rail (TK4C6164C1), and carry out mounting by Z method. pplicable diameter range method: ø50 to ø250 Z method: ø150 to ø400 *4: s standard acoustic coupler, silicone rubber (KE-348W) is provided for small diameter sensor, or grease for high temperature (KS62M) for high-temperature sensor. <, common type> 1 2 3 4 5 6 7 8 9 10 11 FLW 2 Description 120 110 410 510 500 2 Type (4th, 5th and 6th digits) Small sensor (ø50 to ø400) Small sensor* 2 (ø50 to ø400) Middle sensor (ø200 to ø1200) Large sensor (ø200 to ø6000) Large sensor* 2 (ø200 to ø6000) method or Z method Optional specification (7th digit) Tag indication provided Mounting method (11th digit) Standard Z method mounting (for small sensor) *2: For old pipe, or cast iron pipe, mortar lining pipe or others through which the ultrasonic signal could not be transmitted easily, select FLW11 or FLW50. *3: Procure a signal cable of Model FL. *5: s standard acoustic coupler, silicone rubber (KE-348W) is provided. <, submersible type> 1 2 3 4 5 6 7 8 9 10 11 FLW 2 121 111 411 511 501 B C D E F G H J K L M N P Q R Z 2 <, popular type> Description Type (4th, 5th and 6th digits) Small sensor, submersible type (ø50 to ø250) Small sensor, submersible type * 2 (ø50 to ø250) Middle sensor, submersible type (ø200 to ø1200) Large sensor, submersible type (ø200 to ø6000) Large sensor, submersible type * 2 (ø200 to ø6000) Optional specification (7th digit) Tag indication provided Signal cable (9th and 10th digits) 10 m 20 30 40 50 60 70 80 90 100 110 120 130 140 150 Others or Z method or Z method Mounting method (11th digit) Standard Z method mounting (for small sensor) ø50 to ø400 *2: For old pipe, or cast iron pipe, mortar lining pipe or others through which the ultrasonic signal could not be transmitted easily, select FLW11 or FLW50. *3: Procure a signal cable of Model FL. *5: s standard acoustic coupler, silicone rubber (KE-348W) is provided. 1 2 3 4 5 6 7 8 9 10 FLSE 2 1 2 2 2 B B Description Type (5th and 6th digits) Small diameter sensor, 2MNz (ø25 to ø100mm) method Small sensor, 2MHz (ø50 to ø225mm) (Note 1) coustic coupler (7th digit) (Note 2) Silicone rubber Silicone-free grease Fluid temperature range (9th digit) -20 to +100 C 0 to +120 C Optional specification (10th digit) Tag Note 1: When the 9th digit in the code symbol is, the applicable piping diameter is up to 150mm. Note 2: Normally select silicone rubber as acoustic coupler. Silicone rubber in tube (100g) is furnished. If you place an order for several units, 1 tube may suffice for every 5 units. Select silicone-free grease for semiconductor manufacturing equipment or the like that is vulnerable to silicone. The silicone-free grease is water-soluble and, therefore, cannot be used in environment exposed to water or on piping subjected to a condensation. Since the grease does not set, a periodic maintenance (cleaning, refilling every about 6 months at normal temperature) is necessary. 6

CODE SMBOL <Signal cable> For detector FLS 1 2 3 4 5 6 7 8 F L 1 Description 3 005 010 015 020 025 030 040 050 060 ZZZ Type of sensor (4th digit code) (for FLS) Cable length (5, 6 and 7th digit) 5 m 10 m 15 m 20 m 25 m 30 m 40 m 50 m 60 m Others (contact us) Conditions on straight pipe For detector FLW and FLD 1 2 3 4 5 6 7 8 F L 1 Description 8 9 005 010 015 020 025 030 035 040 045 050 055 060 065 070 075 080 085 090 095 100 110 120 130 140 150 ZZZ Type of sensor (4th digit) Small and large sensor (for FLW) Small dia and hight temp sensor (for FLD) Cable length (5,6 and 7th digit) 5 m 10 m 15 m 20 m 25 m 30 m 35 m 40 m 45 m 50 m 55 m 60 m 65 m 70 m 75 m 80 m 85 m 90 m 95 m 100 m 110 m 120 m 130 m 140 m 150 m Others (contact us) Note: Must be procured unless the sensor is a submersible type. Classification Upstream side Downstream side ( D : Inside diameter of pipe) L 5D 90 bend 10D or more L 10D Tee 10D or more L 50D L 10D 10D or more 0.5D or more L 30D L 5D Diffuser D 1.5D L 10D L 50D Reducer L 30D L 10D arious alve Pump In case that flow control valve exists on upstream side. Stop valve Check valve P In case that flow control valve exists on downstream side. L 50D (Note) The source : JEMIS-032 7

FS, FLS/FLW/FLD OUTLINE DIGRM (Unit:mm) 2.5 2.5 Mtg. plate 75 142 1 70 1 10 Mtg. hole 10 9 U bolt (M8) (option) Ultrasonic Flow Meter ESC ENT 200 SS tag (option) 170 (233) Mtg. pipe TIME DELT-C Cable gland 153 Earth terminal (M4) Flow transmitter : FS For sensor cable (PF3/8) For power supply & output cable (PG13.5) SS tag (option) L Sensor BNC connector Frame Lock clip 34 28 (50) H Spacing (djustable every 3mm) Type FLSE12 FLSE22 Pipe size (mm) 25 to 100 50 to 225 L 228 348 H 31 30 Spacing Mass. approx (kg) 21 to 120 0.3 21 to 240 0.4 Detecter (type : FLSE 2) (popular type) 8

OUTLINE DIGRM (Unit:mm) Distance between two sensors 0 to 133 Scale (inch) Scale (mm) Saddle BNC connector Lock nut 320 Spacing (0 to 270) (50 to 250) 500 carsor Element holder 72 36 90 max Sensor Name plate Pipe 52.5 FLD22 (Small diameter sensor) 80 60 Frame end GND. terminal 40 Chain & spring 104 114 FLW1 (Small sensor) 93 Saddle Wire rope Mtg. spring Scale (inch) Scale (mm) 33 62 BNC connector FLW5 (Large sensor) Distance between two sensors 0 to 330 Lock nut 530 Element holder carsor 33 72 114 Ø26 33 90max 205max 60 Wire rope Mtg. spring 40 Ø19 Ø19 FLW4 (Middle sensor) 52 FLD32 (High-temperature sensor) 9

FS, FLS/FLW/FLD OUTLINE DIGRM (Unit:mm) Signal cable : FL3 (For FLS) ø15 BNC connector Signal cable : FL8 (For FLW) 8 3-ø4.3 41 To To ø11 30 ø5 ø7.3 +1 L 0 (m) +1 L 0 (m) To Flow transmitter To Flow transmitter 5.5 ø3.2 L : By specification when ordered. Signal cable : FL9 (For FLD) ø14.5 5.5 3-ø3.2 L : By specification when ordered. Loader cable : ZZP TK4J1236 34 Connector BNC connector 46 ø11 30 67 ø7.3 To To Personal computer +1 L 0 (m) 3.2±0.2 (m) ø6.9 10 3-ø3.2 5.5 To Flow transmitter L : By specification when ordered. Terminal cap (Red) 3-ø3.2 To Flow transmitter Terminal cap (ellow) Terminal cap (Black) TXD RXD COM 5.5 Red ellow Black

CONNECTION DIGRM <Flow transmitter> C power supply DC power supply Option Earth terminal 1 2 3 4 1 2 3 4 1 2 3 4 (M4) L N + DI1 SHILD TXDR2 TXDR1 <> G + C100 to 240 50/60Hz DC20 to 30 Status input (DI) RS-485 To flow transmitter 1 2 3 4 5 + + 6 7 + 8 9 + 10 GND 11 HF1 12 13 GND HF2 1 2 3 DI1 GND RXD 4 TXD DO1 TR out DO2 TR out Max. DC30, 0.1 DO3 I out REL Max. C240/ DC30, 1 SH *1 SH *1 To downstream-side sensor Status input (DI) RS-232C To upstream-side sensor *1) Only for double shield coaxial cable (type FL8, 9) SCOPE OF DELIER Flow transmitter (provided with U-bolt and nuts for pipe mount) (provided with mounting fixture and acoustic coupler) *The acoustic coupler is option for popular type detectors. CD-ROM (contains instruction manual, loader software) ITEMS DESIGNTED ORDERING 1. code symbols 2. Flow transmitter code symbols 3. Signal cable code symbols 4. For large sensor: Mounting pipe size 5. Tag No. as necessary 6. If parameter setting is specified, send back the attached parameter specification table duly filled. OPTIONL CCESSURIES Name Drawing No. 1 Guide rail for high-temperature sensor ZZP TK4C6164C1 2 Loader cable ZZP TK4J1236 3 Silicon grease ZZP FLD1-C100 11

FS, FLS/FLW/FLD <Parameter specification table> Setting item Initial value Setting value Setting item Initial value Setting value ID No 0000 Total mode Stop Language English Total rate 0m 3 System unit Metric Total preset 0m 3 Flow unit m 3 /h Pulse width 50.0msec Total unit m 3 Burnout (total) Hold Outer diameter 60.00mm Burnout timer 10sec Pipe material PC pipe DO1 output type (Note 1) Not used Wall thickness 4.00mm DO1 output actuation ON when actuated Lining material Without lining DO2 output type Not used Lining thickness DO2 output actuation ON when actuated Kind of fluid Water DO3 output type Not used iscosity 1.0038 10-6 m 2 /s DO3 output actuation ON when actuated Sensor mount metod DI1 input type Not used Sensor type FLS_12 DI1 input actuation ON when actuated Transmission voltage 80pp Operation mode Standard Damping 5.0sec Communication mode RS-232C Cut off 0.150m 3 /h Baud rate 9600bps 1st line Flow velocity (m/s) Parity Odd 1st line decimal point position ****.*** Stop bit 1 bit 2nd line Flow rate (m 3 /h) Station No. 1 2nd line decimal point position ****.*** Range type Single range Full scale 1 15.000m 3 /h Full scale 2 0.000m 3 /h Range HS. 10.00% Burnout (current) Hold Burnout timer 10sec Output low limit -20% Output high limit 120% Rate limit 0.000m 3 /h Rate limit timer 0sec Measuring conditions Output conditions Display nalog output Note1: When total pulse output has been selected for DO1, DO2 or DO3 specify total pulse value and total pulse width so that conditions 1 and 2 shown below are satisfies. Communication Output conditions Total output Condition 1 : Condition 2 : Flow span-1*[m 3 /s] total pulse value*[m 3 ] Flow span-1*[m 3 /s] total pulse value*[m 3 ] 1000 [In the case of DO1 and DO2] 1 [In the case of DO3] 1000 2 total pulse width [ms] * In the case of 2 ranges, perform calculations using either flow span-1 or flow span-2, whichever is greater. Caution on Safety *Before using this product, be sure to read its instruction manual in advance. Head Office Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fesys.co.jp/eng Instrumentation Div. International Sales Dept. No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http://www.fic-net.jp/eng Information in this catalog is subject to change without notice. Printed in Japan