TAKE A CLOSER LOOK AT POWERVIEW. THE LATEST ADDITION TO THE MURPHYLINK TM FAMILY.

Similar documents
Electric Gage Shutdown Panels for DEUTZ 1011/2011, 912/913 and 914

MurphyLink Series M310 Panels

NOTICE FOR ALL EG21 ELECTRIC GAGES AND EGS21

WARNING. Diode Package The Murphy diode package ( ) is designed to allow the fuel shutoff valve to be used with dual Magneto Ignition systems.

MurphyLink Series M310 Panels

WARNING. Models Magnetic Sensor Tachometer 3000 RPM; pulses 12 VDC

Your Source for Engine and Equipment Management. Oil & Gas

Shock/Vibration Control Switches Installation Instructions Models: VS2, VS2C, VS2EX, VS2EXR, VS2EXRB and VS94 GENERAL INFORMATION LISTED*

WARNING. Autostart AS710S/AS730S V1.05 V1.07 Autostart AS705S V1.00 V1.05 Installation Instructions

Frank W. Murphy Ltd. Control Panel Catalogue

ENGINE LIFE EXTENDED

PowerView PV380-R2 Mechanical Configuration

POWER CONTROLS. Complete Solutions to Meet Your Needs.

Murphy-Link Series Panels Models ML25, ML50, ML100 ML150, and ML300. Installation and Operations Manual Section 30

CAN Instruments CANcockpit* Ocean Link Accessories. * Only for trained partners

Electric Gage Shutdown Panels for DEUTZ 1011/2011, 912/913 and 914

Model H30 Operation Manual

Operations Manual *Products covered in this document comply with European Council electromagnetic compatibility directive 2004/108/EC and electrical

FWMURPHY. Industrial Applications. Oil & Gas Applications. Condensed Catalog. Control & Instrumentation. Solutions

Instrument Solutions for. Lawn and Garden Off Road Industries

World Class Engine Monitoring and Analog Instrumentation

Tachometers and Tach/Hourmeters AT and ATH Series

Digital Instrumentation Model 3501

Operation Manual. For technical help please contact Livorsi Marine at or us at

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75

Operations Manual *Products covered in this document comply with European Council electromagnetic compatibility directive 2004/108/EC and electrical

2011 Special OEM Instrumentation Catalog

Elite stainless steel bezels White graphics and black background on spun aluminum dials

System III Wiring Information 54-12

Reference Manual C1S Class 1 Systems

3 3/8" NMEA, J1939, INDMAR SMALL RPM TACH w/ POLISHED SS RACE or MEGA RIM

PowerView PV380 R1 Murphy Standard Configuration

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

2 diameter gauges (nominal), panel cut-out /-.02 ; 3-3/8 diameter tachometer/speedometer (nominal), panel cut-out /-.

PRESSURE GOVERNOR, ENGINE MONITORING, AND MASTER PRESSURE DISPLAY MODEL: TCA100

TOUGH, RUGGED CONTROLLERS

Classic style with a name you can trust

MIC4 IGNITION CONTROLLER

Switch select of sender types:

SUZUKI INSTRUMENTS. 4 Speedometer. 4 Tachometer. 2 Fuel Gauge

Owner s Manual. MG2000 Speedometer IS0211. for use with SmartCraft Tachometer

AT EVO SERIES BATTERY CHARGER

A comprehensive family of instruments for outboards, stern drives and inboards, including diesels!

OceanLink easy to install VDO CAN instrumentation for sports boats.

Sentry Governors. Class 1. Advanced Diagnostics. Sentry Governor Kits

NexSysLink. Operation Manual. NMEA 2000 SAE J1939 Indmar Engines. CAN Instruments Product Family

Factory Packaged Controls. OE (AAON Part No. V12090) MODGAS-X Controller Field Technical Guide

ROBICON W120 enclosed drive

RENEWABLE ENERGY TRAINER

Commander IS0128 ISO128E ECR# /04. Tachometer/ Engine Hourmeter

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

T H E K A n t r a k S E R I E S D I S P L A Y I N S T A L L A T I O N M A N U A L

HGM1750 Genset Security Module USER MANUAL Smartgen Technology

High-impact moisture-resistant polyester (PBT)

Hour Meter Series HM36

Serial Bus. Owners s Manual IS0210. for Navy Gateway GW0016

The company 4. CM Series Engine Control Panel 6 CM 40 Series CM 20/30 Series CM 2A/3A Series CM 02 Series CM 60 Series

ATevo SERIES BATTERY CHARGER

EMS-2. Introduction. Features. Engine Management System. Operating Manual English 1.07

QUANTUM LX CONTROL PANEL

IS0306 rev. B ecn /2013. MG Tachometer (NMEA2000 and J-1939) TACH 1760 RPM FUEL. Installation / User Manual.

POWER DIGITAL SWITCHBOARD METERS

INSTALLATION MANUAL KAntrak 1700

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER

A comprehensive family of instruments for outboards, stern drives and inboards, including diesels!

MATRIX LLC LEVEL CONTROL PANEL

DGC-2020 DIGITAL GENSET CONTROLLER

SPREADER SYSTEM. Proportional three function. 1. Features and Specifications. User Manual 12 INPUTS 12 OUTPUTS CONNECTIVITY MAIN FEATURES

AT SERIES EVO BATTERY CHARGER

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

Air Circuit Breakers

e -Stroke e-s 3 / GEN 3 Tractor / Truck / Bus Parts List

CONTENTS ESC CONTENTS... 1 FEATURES... 2 LAYOUT... 3 DISPLAYS... 4 CONNECTIONS... 5 MENU... 6 MESSAGES... 7 SYSTEM OPERATION... 8

XC Instrumentation System Owner s Manual Revision /05/06

2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device

DCA400SSI4F. WhisperWatt 400. MQ POWER Whisperwatt Series. Prime Rating 320 kw (400 kva) Standby Rating 336 kw (420 kva)

Power System Measurements. Made in U.S.A. Power Series Plus. Digital Switchboard Meters.

Distinctive Characteristics

Light Bar Control Unit (LBCU) 54.08

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Special OEM Solutions Catalog Sensors

Full Sweep Minor Gauge Wiring:

Types E2 and D2. Types Q and L. Including products with: Digital Precision Pressure Gauges

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

Instrument Enclosure Assemblies

DEEP SEA ELECTRONICS PLC

EVO AT SERIES BATTERY CHARGER

GEPA. ARG-24 Series Battery Charger & Battery Group. User Guide

8000 Series Liquid Flow Meter

Intelli-Feed Controller User s Manual Intelli-Feed Digital Tachometer and Hourmeter

OPERATING INSTRUCTIONS ECON-M

Oil Pressure Display Gauges Part numbers: Analog Oil/Fuel SAE Pressure Gauge psi Analog Oil SAE Pressure Gauge.

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

Product Manual. Part Number: MVP-193 Mefi-6 ECU Revision: 1.0

This document set is applicable to the following part number configurations:

Energetic independence

A91 Series MURPHYMATIC Engine Microcontroller Installation and Operation Manual Models A91, A91-S, A91-WC, and A91-S-WC Option -LC (less case)

RVS-DN Digital Reduced Voltage Motor Starter

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

8000 Series Liquid Flow Meters

Transcription:

TAKE A CLOSER LOOK AT POWERVIEW. THE LATEST ADDITION TO THE MURPHYLINK TM FAMILY.

INTRODUCING THE NEXT GENERATION MURPHYLINK SYSTEM. POWERVIEW INSTRUMENTS AND GAGES ARE THE MOST ADVANCED J1939 CAN SOLUTIONS FOR WHATEVER APPLICATION YOU RE RUNNING. WHETHER YOU NEED INSTRUMENTS FOR MOBILE OR STATIONARY APPLICATIONS, POWERVIEW IS THE SOLUTION FOR ALL YOUR EQUIPMENT.

} NOW YOU KNOW WHAT YOUR ELECTRONIC ENGINE IS TELLING YOU. N ow, with PowerView, operators see what your engine s Electronic Control Unit (ECU) is telling them in plain text. It puts the information where it s needed most at the operator s fingertips. A large LCD graphical display and smooth gage pointer operation makes the PowerView and associated gages easier to use and understand. PowerView gives you choices in bezel designs and colors. Even better, all PowerView components feature plug and go convenience for easy installation, and they re available in both standard and custom panels. With years of experience, nobody knows more about J1939 CAN instrumentation than we do. Just what you d expect from a company with a 60-year heritage as the Engine Protection Company. Spec the new PowerView system today.

Available Instrumentation. PowerView features a large graphical screen with a great viewing angle and contrast PowerView Audible Alarm alerts operators to fault conditions via piezoelectric alarm and relay contacts Multiple bezels and color options available PowerView Analog Gages display information transmitted from the PowerView in the traditional analog formats shown below: 1 2 3 4 5 6 Tachometer Engine Oil Pressure Engine Coolant Temperature 12 or 24 VDC Voltmeter Percent Load Audible Alarm (See PowerView Analog Gage information for other options available) Accurate, Reliable Operation. Accurate electronic engine and transmission data via SAE J1939 CAN PowerView translates information from electronic engines for precise operation of gages or remote communication All PowerView components are environmentally sealed Wide operating temperature range Enhanced Gage Design. Gages are stepper motor driven allowing smooth pointer operation Stepper motor design provides more linear scale, less pointer bounce PowerView Analog Gages feature intelligent communications Self-diagnostics available on start-up for PowerView Analog Gages Understandable Diagnostics. PowerView displays standard J1939 fault codes with text descriptions for common faults Ultra-bright alarm and shutdown LEDs Large, easy-to-read fault symbols displayed Easy-to-Read & Use. PowerView features fully graphical LCD screen Four touch-sensitive buttons feature increased size and spacing for scrolling and parameter selection Display information in single or quadrant (4 parameter) views Long-lasting green LED backlighting for both the PowerView and PowerView Analog Gages Backlighting intensity adjustable via PowerView menu or external dimmer potentiometer PowerView Analog Gages feature 270 pointer sweep Convenient Installation Options. PowerView fits standard 2-1/16 in. (52 mm) hole opening Powerview Analog Gages available in standard 2-1/16 in. (52 mm) and 3-3/8 in. (86 mm) size hole openings Two 6-pin Deutsch TM DT style connectors molded into casing for quick connections and simple daisy-chain wiring Standard connection harnesses available "Plug and Go" standard and customizable panels available with harnesses for all major engine manufacturers

specifications PV100 Dimensions FRONT 4.25 in. (108 mm) SIDE 2.41 in. (61 mm) 0.78 in. (20 mm) 3.18 in. (81 mm) 1.94 in. (50 mm) 3.489 in. (89 mm) 2.070 in. (53 mm) 2.062 in. (52 mm) diameter BACK 4.25 in. (108 mm) HOLE CUTOUT 0.125 in. (3 mm) 1.972 in. (50 mm).953 in. (24 mm) R 0.063 in. (1.6 mm) Specifications Display: 1.3 x 2.6 in. (33 x 66 mm), 64 x 128 pixels. Operating Voltage: 8 VDC minimum to 32 VDC maximum. Reversed Polarity: Withstands reversed battery terminal polarity indefinitely within operating temperatures. Operating Temperature: -40 to +85ºC (-40 to185ºf). Display Viewing Temperature: -40 to +75ºC (-40 to 167ºF) Storage Temperature: -40 to +85ºC (-40 to185ºf). Environmental Sealing: IP68, +/- 5 PSI (+/- 34.4 kpa). Power Supply Operating Current (@ 14 VDC): 52 ma minimum; 268 ma maximum (LCD heater on). CAN BUS: SAE J1939 Compliant. Case: Polycarbonate / Polyester. Clamp: Polyester (PBT). Connectors: 6-Pin Deutsch DTO6 Series. Maximum Panel Thickness: 3/8 in. (9.6 mm). Mounting Hole: 2.062 inch (52 mm) in diameter. Auxiliary Communications (Gage): One (1) RS485 port, MODBUS RTU master, 38.4K baud, N, 8, 1 or 2, half duplex. Potentiometer Input: 1K ohm, 1/4 W Shipping Weights (all models): 1 lb. (450 g.) Shipping Dimensions (all models): 6 x 6 x 6 in. (152 x 152 x 152 mm). 03014H Rev. 9-04

specifications PVA20 / PVAA20 Dimensions Specifications FRONT Ø 2.324 in. (59 mm) Gray Area shows Domed lens style BACK 2.062 in. (52 mm) diameter 0.125 in. (3 mm) 2.430 in. (62 mm) 2.050 in. (52 mm) 0.48 in. (12 mm) HOLE CUTOUT PVA35 Dimensions FRONT BACK Ø 3.630 in. (92 mm) Gray area shows Domed Lens style. 3.375 in. (86 mm) diameter 0.125 in. (3 mm) 1.972 in. (50 mm) R 0.063 in. (1.6 mm) 2.475 in. (63 mm) 2.09 in. (53 mm) 0.48 in. (12 mm) HOLE CUTOUT.953 in. (24 mm) 1.956 in. (50 mm) OR R 0.063 in. (1.6 mm) 3.268 in. (83 mm) Screw-on Type Mounting Clamp Use a 2.062 in. (52 mm) diameter round hole. 3.285 in. (83 mm) Screw-on Type Mounting Clamp 1.610 in. (41 mm) 2 Push-on Type Plug Connectors 2 Push-on type Plug Connectors OR Use a 3.375 in. (86 mm) diameter round hole. Power Supply Input Voltage: 12/24V (8-32VDC min. & max. voltage) Power Supply Operating Current: (@ 14 VDC) = PVA20, PVA35: 28 ma minimum; 52 ma maximum. PVAA20: 19 ma minimum; 46 ma maximum. Backlight Maximum Current (excludes PVAA20): 24 ma. Input: RS485 MODBUS RTU data Output: Analog Readout. Relay Rated Load (PVAA20): 0.5 A, 125 VAC; 1 A, 24 VDC. Relay Maximum Switching Capacity (PVAA20): 62.5 VA, 30W. Audible Alarm Output (PVAA20): 28 VDC, 30 ma max. (current sink). Temporary Silence Button (PVAA20): Charge transfer technology. Storage Temperature: -76 to 185 F (-60 to 85 C). Dial: White numerals over black background. Indicating Pointer: Stepper motor operation with 270 sweep. Gage Accuracy: PVA20/35: Better than ±1.0% of scale. PVA35: Better than ±2% of scale. Environmentally Sealed Enclosure: Sealing: IP68, ±5 psi (±34.4 kpa). Case and Clamp Material: Polyester (PBT). Lens Material: Polycarbonate. Bezel Material: Polyester (PBT). Maximum Panel Thickness: 3/8 in. (9.6 mm). Mounting Holes: 2.062 inch (52 mm) in diameter. 3.375 inch (86 mm) in diameter. Connectors: 6-Pin Deutsch DT06 Series. 03017H Rev. 9-04

flat lens bezel options A-20 Style Low Profile SAE Style Contemporary Style Low Curved Style AB Bezel Type BB Bezel Type CB Bezel Type DB Bezel Type PVA20 Series - Gages A Bezel Type B Bezel Type C Bezel Type D Bezel Type PVA35 Series- Tach & Speedometer AB Bezel Type A Bezel Type BB Bezel Type B Bezel Type CB Bezel Type C Bezel Type DB Bezel Type D Bezel Type PVAA20 - Audible Alarm AB Bezel Type BB Bezel Type CB Bezel Type DB Bezel Type A Bezel Type B Bezel Type C Bezel Type D Bezel Type 03016H Rev. 9-04

domed lens bezel options 1. Domed Lens E- Bezel Style Contemporary Domed Bezel and Lens Style 1. Domed Bezel EB Bezel Type EB Bezel Type EB Bezel Type E Bezel Type E Bezel Type E Bezel Type PVA20 Series - Gages PVA35 Series- Tach & Speedometer PVAA20 - Audible Alarm 03019H Rev. 9-04

wire harnesses Typical Quick-Connect Diagram To Engine ECU A B Last PVA Gage or PVAA Audible Alarm To PVAA Audible Alarm To optional external device PVW-CH PVW-PH To Battery Power Customer provided wire harness or CAN extension harnesses or power extension harnesses. External Dimmer Wire 24 inch. POWERVIEW PV100 A B Terminating Resistor PVJR PVA Gage OR A B Optional PVW-A wire harness (includes terminating resistor) Next PVA Gage Wire harness PVW-J Relay N.O. Relay N.C. Ext. Sonalert Relay Comm. External Dimmer B+ GRND A B A B CAN SHLD CAN LO CAN HI Wire harness PVW-P Wire harness PVW-J Wire harness PVW-J Optional PowerView Wiring Models (PVW) External Wiring Harnesses Model Length Description PVW-CH-72 72 in.(6 ft) PowerView Extension Harness PVW-CH-144 144 in. (12 ft) PowerView Extension Harness PVW-CH-240 240 in. (20 ft) PowerView Extension Harness PVW-CH-360 360 in. (30 ft) PowerView Extension Harness PVW-PH-72 72 in. (6 ft) Battery Power Extension Harness PVW-PH-144 144 in. (12 ft) Battery Power Extension Harness PVW-PH-240 240 in. (20 ft) Battery Power Extension Harness PVW-PH-360 360 in. (30 ft) Battery Power Extension Harness PVW-CC-24 24 in. PowerView CAN Loose Wiring PVW-PC-24 24 in. Battery Power Loose Wiring PVW-CT *Includes J1939 CAN 120 ohm resistor. CANBUS Tee Harness Internal Wiring Harnesses Model Length Description PVW-P-12 12 in. PowerView CAN and Power Harness* PVW-P-24 24 in. PowerView CAN and Power Harness* PVW-PW-30 30 in. CAN and Power Harness w/loose wires* PVW-J-9 9 in. PowerView Jumper Harness PVW-J-12 12 in. PowerView Jumper Harness PVW-J-24 24 in. PowerView Jumper Harness PVW-A-9 9 in. Audible Alarm Jumper Harness PVW-A-12 12 in. Audible Alarm Jumper Harness PVW-A-24 24 in. Audible Alarm Jumper Harness PVJR Jumper Terminating Resistor PVW-K-12 12 in. Wiring Kit 24 in. Includes: (1) PVW-P, qty 1 (2) PVW-J, qty 4 (3) PVJR 03018H Rev. 9-04

how to order To Order Your PowerView Module Use This Designation Diagram: PV100 A Model PV100 = PowerView Blank = Standard GM = For use only on GM MEFI ECU General Motors * Model Style A = Black Overmold Faceplate with Silver Bezel To Order Your PowerView Gages Use This Designation Diagram: PVA20 A 100 A R1 Model PVA20 = 2 inch size PowerView Gage PVA35 = 3-1/2 inch size PowerView Gage (Tachometer or Speedometer only) PVAA20 = 2 inch PowerView Audible Alarm Gage Function (excludes PVAA20) A= Engine Oil Pressure B= Coolant Temperature C= Voltmeter D= Percent Load @ Current RPM E= Transmission Oil Pressure F= Transmission Oil Temperature G= Engine Oil Temperature J= Fuel Level T= Tachometer S= Speedometer *Please see sales bulletins for exact features and specifications. Bezel (All Models) Bezel Type (flat lens) A = A20 (Brushed Silver) AB = A20 (Black) B = Low profile SAE (Brushed Silver) BB = Low profile SAE (Black) C = Contemporary (Brushed Silver) CB = Contemporary (Black) D = Low Curved (Brushed Silver) DB = Low Curved (Black) Bezel Type (domed lens) E = Contemporary Domed (Brushed Silver) EB = Contemporary Domed (Glossy Black) Gage Ranges (excludes PVAA20) Available for Gage Functions 100 =100 psi/700 kpa A 100 =100% Load @ Current RPM D 100 =% Fuel Level J 150 =150 psi/1000 kpa (PVA20-A only) A 250 =250 F/120 C B, F, G 12 =12 VDC C 24 =24 VDC C 400 =400psi/28 bar E 3000 =3000 RPM T 85 =85 MPH S 7B =7 Bar/100 psi A 10B =10 Bar/150 psi A 28B =28 Bar/400 psi E Remote Gage R1 = Option for a second gage of identical type on the gage network. For example: If you are already using one PVA20-A-100-A, and a second oil pressure gage is needed, order a PVA20-A-100-A-R1. 03035H Rev 9-04

MSeries panels Connecting To Electronic Engines Doesn t Have To Be Complicated. Now You Can Just "Plug And Go." Plug and Go M110 Panels Plug and Go M310 Panels Plug and Go Custom Panels Standard Harnesses Adapt All Panels To Most Engine ECUs. With MurphyLink panels, we ve made it simple and easy to connect to modern electronic engines using the SAE J1939 Controller Area Network (CAN). We ve done the work so you don t have to. Our next-generation panels include PowerView, the most advanced J1939 CAN display system available. You get a large graphical, highresolution, backlighted LCD screen that provides a clear look inside modern electronic engines. PowerView displays over 30 standard SAE J1939 parameters, and its diagnostic capabilities include fault codes with text translations for most common fault conditions. Standard harnesses make basic and deluxe panels interchangeable Simple connections for easy installation with minimal training Available for most major electronic engines Includes Deutsch connectors Available in enclosed design or flat panel option MS-04054H Rev. 9-04

For more information about PowerView products, phone (918) 317-4100, fax (918) 317-4266, or visit our website at www.fwmurphy.com. Warranty. A two-year limited warranty on materials and workmanship is given with the PowerView products. Details are available on request and are packed with each unit. P.O. Box 470248 Tulsa, Oklahoma 74147 USA (918) 317-4100 fax (918) 317-4266 e-mail sales@fwmurphy.com www.fwmurphy.com CONTROL SYSTEMS & SERVICES DIVISION P.O. Box 1819; Rosenberg, Texas 77471; USA (281) 633-4500 fax (281) 633-4588 e-mail sales@fwmurphy.com MURPHY DE MEXICO, S.A. DE C.V. Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje San Luis Potosí, S.L.P.; México 78384 +52-444-8206264 fax +52-444-8206336 Villahermosa Office +52-993-3162117 e-mail ventas@murphymex.com.mx www.murphymex.com.mx FRANK W. MURPHY, LTD. Church Rd.; Laverstock, Salisbury SP1 1QZ; U.K. +44 1722 410055 fax +44 1722 410088 e-mail sales@fwmurphy.co.uk www.fwmurphy.co.uk MURPHY SWITCH OF CALIFORNIA 41343 12th Street West Palmdale, California 93551-1442; USA (661) 272-4700 fax (661) 947-7570 e-mail sales@murphyswitch.com www.murphyswitch.com MACQUARRIE CORPORATION 1620 Hume Highway Campbellfield, Vic 3061; Australia +61 3 9358-5555 fax +61 3 9358-5558 e-mail murphy@macquarrie.com.au Printed in U.S.A. 04138A Rev. 09-04 In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time. MurphyLink is a registered trademark of FWMurphy Company. All other trademarks and service marks used in this document are the property of their respective owners. RE GISTE RED