B CW POWER RELAY

Similar documents
COM Overcurrent Relay

P. Sub 4 184A404. Sub 3 876A220

Type CRN-1 Reverse Power Relay 50 and 60 Hertz

C. Figure 1. CA-16 Front View Figure 2. CA-16 Rear View

3.0 CHARACTERISTICS E Type CO-4 Step-Time Overcurrent Relay

2.0 CONSTRUCTION AND OPERATION 3.0 CHARACTERISTICS K. CO (HI-LO) Overcurrent Relay

Figure 1. Type CWP-1 Ground Relay (Front View) Figure 2. Type CWP-1 Ground Relay (Rear View) E

TYPE KF UNDER-FREQUENCY RELAY A. Figure 1: Type KF Relay for 60 Hertz without Case. (Front & Rear View.) Front View Rear View

L. Photo. Figure 2: Types CA-16 Relay (rear view) Photo. Figure 1: Types CA-16 Relay (front view)

ABB. Type CRQ Directional Negative Sequence Relay for Ground Protection B 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION CAUTION

A - Add New Information C - Change Existing Information D - Delete Information. Page 7. Delete the fourth paragraph beginning CAUTION

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet

ABB Automation Inc. Substation Automation and Protection Division Coral Springs, FL 33065

41-747G. Figure 1: Type DGF Relay without case (Photo)

TABLE I 60 CYCLE BURDEN OF THE CVD RELAY AT CONTINUOUS RATING

ABB Automation, Inc. Substation Automation & Protection Division Coral Springs, FL Allentown, PA

INSTRUCTIONS. seconds. the tween the end of the bearing screw and the. top of the shaft. The moving contact is a small silver hemisphere

4.0 OPERATION Type ITH-T Relay

ABB Power T&D Company Inc. Relay Division Coral Springs, FL Allentown, PA. Non-Directional, Single Phase Adjustable Time Delay Device No.

www. ElectricalPartManuals. com INSTRUCTIONS TYPE CO CONTACT MAKING AMMETER INSTALLATION OPERATION MAINTENANCE I.. L APPLICATION

2.0 CONSTRUCTION 3.0 OPERATION. SA-1 Generator Differential Relay - Class 1E 2.5 TRIP CIRCUIT

3. OPERATION 2.1. RESTRAINT CIRCUIT 2.6. INDICATING CIRCUIT 2.2. OPERATING CIRCUIT 2.7. SURGE PROTECTION CIRCUIT 2.3.

Type SOQ Negative Sequence Time Overcurrent Relay

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

www. ElectricalPartManuals. com Type CO Overcurrent Relays E ABB Power T&D Company Inc. Relay Division Coral Springs, FL Allentown, PA

www. ElectricalPartManuals. com INSTRUCTIONS TYPE HQS PHASE SELECTOR RELAY FOR INSTALLATION OPERATION MAINTENANCE APPLICATION

Instructions for Replacing

INSTRUCTIONS. GEI-38974A Supersedes GEI INSTANTANEOUS CURRENT RELAY TYPE PJC2OA GENERALS ELECTRIC

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

1. Take the cover off the relay, taking care to not shake or jar the relay or other relays around it.

INSTRUCTIONS HAA 15A / 15B / 15C / 15D / 15E / 15F / 15G / 15H AUXILIARY CURRENT RELAYS

To discover the factors affecting the direction of rotation and speed of three-phase motors.

www. ElectricalPartManuals. com INS T R U c.t I 0 N S Westinghouse OPER.ATION MAINTENANCE INSTALLATION SWITCHBOARD INSTRUMENTS SIX-INCH CLASSIFICATION

Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay

www. ElectricalPartManuals. com INSTRUCTIONS Westinghouse 1. L F TYPE CVQ RELAY OPERATION MAINTENANCE INSTALLATION APPLICATION

Transmission & Distribution Glossary of Electrical Terms

THERMAL OVER CURRENT RELAY

INSTRUCTIONS. GE Protection and Control. 205 Great Valley Parkway Malvern, PA UNDERVOL TAGE RELAYS TYPES: IAV54E IAV55C IAV54F IAV55F

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

INSTRUCTIONS SYNCHRONISM-CHECK RELAYS. GE Meter and Control. 205 Great Valley Parkway Malvern, PA Types IJS51A.

Control Relays Overview

Cutler-Hammer. Installation Instructions for the Digitrip OPTIM Pole Trip Unit Installation and Operation with L-Frame Series C Circuit Breakers

www. ElectricalPartManuals. com INSTRUCTIONS TYPE CT TEMPERATURE-OVERLOAD RELAY INSTALLATION OPERATION MAINTENANCE I.L

Horizontal Circuit Switchers

Horizontal Circuit Switchers

SURE TRIP RETRO KITS

RELAYS HAVING NO KS DESIGNATIONS WARD LEONARD COMPANY, ALLEN-BRADLEY COMPANY AND WESTINGHOUSE CORPORATION REQUIREMENTS AND ADJUSTING PROCEDURES

Electric Motor Controls BOMA Pre-Quiz

34 th Hands-On Relay School

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

SURE-TRIP OEM RELACEMENT TRIP UNIT

Module 2 CONTROL SYSTEM COMPONENTS. Lecture - 4 RELAYS

GP/GPA GROUND FAULT PROTECTION

ichards MANUFACTURING COMPANY, SALES, INC. 517 LYONS AVENUE, IRVINGTON, NJ Phone Fax

MAGNETIC MOTOR STARTERS

SECTION MOTOR CONTROL

MANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES M450

INSTRUCTIONS GEK G HIGH-SPEED DIFFERENTIAL RELAYS TYPES CFD22A AND CFD22B. GE Protection and Control

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012

INSTRUCTIONS. GE Protection and Control 205 Great Valley Parkway Malvern, PA GLK 34117G

GEK41931B INSTRUCTIONS MULTI-CONTACT AUXILIARY RELAYS TYPE HFA73K. GE Protection and Control 205 Great Valley Parkway Malvern, PA

PT-150 PLUG-IN THERMAL RELAY WITH SNAP-ACTION BACK CONTACT *****************

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER


Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Instruction Bulletin. Jockey Pump Controller

Electric motor testing

MX431 Generator Automatic Voltage Regulator Operation Manual

PB-500 Pin Drive, PB-500 Spline Drive PB-650 Pin Drive

A. Submit manufacturer's literature and technical data before starting work.

320 to 327 M Series Low and Medium Voltage Motor Protection Relays

GEF Renewal Pans. low Vohage Power Circuit Breakers. Type AKR-30S and AKRU-30S. www. ElectricalPartManuals. com

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

Power Factor Correction

1.0 Features and Description

Exercise 5-1. Primary Resistor Starters EXERCISE OBJECTIVE DISCUSSION. Understand how primary resistor starters operate.

A1500, A1500NF SPEED SWITCH SINGLE SET POINT - SELF CONTAINED. Introduction

HGA. Hinged Armature Auxiliary. Hinged armature auxiliary relay to perform auxiliary functions in AC and DC circuits.

EEE3441 Electrical Machines Department of Electrical Engineering. Lecture. Introduction to Electrical Machines

2014 ELECTRICAL TECHNOLOGY

Series Motor Protection

www. ElectricalPartManuals. com MAGNETIC TIME RELAYS GENERAL. ELECTRIC INSTRUCTIONS *IC *Also identified with prefix CR instead of IC.

CHEC"'- INSTRUCTION UNION SWITCH & SIGNAL.. SWISSVALE, PA. DIVISION OF WESTINGHOUSE AIR BRAKE COMPANY

AC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave

ROTATING MAGNETIC FIELD

PORTABLE CURRENT SOURCE FOR CIRCUIT BREAKER AND MOTOR OVERLOAD TESTING INSTRUCTION MANUAL PI-250B. Release 1.0 April 5, 2013

INSTRUCT ION S GEK A. Supersedes GEK TIME OVERCURRENT RELAY TYPE IAC66S GENERAL ELECTRIC

www. ElectricalPartManuals. com INSTRUCTIONS "INERTEEN AND OIL INSULATED FEEDER SWITCHES DESCRIPTION INSTALLATION MAINTENANCE

Experiment 3. The Direct Current Motor Part II OBJECTIVE. To locate the neutral brush position. To learn the basic motor wiring connections.

INDUCTION MOTOR. There is no physical electrical connection to the secondary winding, its current is induced

UNIT 2. INTRODUCTION TO DC GENERATOR (Part 1) OBJECTIVES. General Objective

Primary Brake Spline Drive Armature PB-825, PB-1000, PB-1225, PB-1525

TRAC-3 TENSION READOUT AND CONTROL

INSTRUCTION MANUAL FOR. VOLTAGE REGULATOR Model: APR Part Number:

Design Standard. Purpose: Design Standard:

MICRO WELD MODEL AUF-8 HEAVY DUTY FERROUS BUTT WELDERS MICRO PRODUCTS COMPANY SERVICE MANUAL

Transcription:

41-241.31B CW POWER RELAY nected in such a way that current, (I A ), leads voltage, (V BA ), by 150 degrees when the motor is operating at unity power factor. Loss of excitation to the motor causes a large var flow into the motor without appreciable change in the watt flow. As the current goes more lagging, operation of the CW permits tripping or alarm action. 2.0 CONSTRUCTION The relay consists of a product operated unit, a phase shifter and an indicating contactor switch (ICS), shown in Figure 1, page 6. 2.1 PRODUCT TYPE UNIT The electromagnet for the main element has a tapped current coil located on the center leg of an E type laminated structure and two potential coils on the outer legs. This is shown schematically in Figure 2, page 6. Operating torque is obtained by energizing the tapped coil with line current and the two outer coils with line potential from the line potential transformers. Out of phase air gap fluxes necessary to operating torques are produced by a phase shifting network in conjunction with the potential coils. Maximum torque occurs when the current leads the voltage by 30 degrees as illustrated in Figure 3, page 7. The voltage is independent of the direction of power flow. This provides a reference so that the disc can rotate in either direction depending upon direction of the line current. The combination of voltage and current produces an operating torque proportional to power. 2.1.1 Phase Shifter - The phase shifter network consist of a resistor in series with the potential coils. 2.2 INDICATING CONTACTOR SWITCH UNIT (ICS) The dc indicating contactor switch is a small clapper type device. A magnetic armature, to which leaf-spring mounted contacts are attached, is attracted to the magnetic core upon energization of the switch. When the switch closes, the moving contacts bridge two stationary contacts, completing the trip circuit. Also during this operation two fingers on the armature deflect a spring located on the front of the switch, which allows the operation indicator target to drop. The target is reset from the outside of the case by a push-rod located at the bottom of the cover. The front spring, in addition to holding the target, provides restraint for the armature and thus controls the pickup value of the switch. 3.0 CHARACTERISTICS The type CW relays are available in the following ranges and taps: Volts Line- to- Line 120 208 Range 20-120 100-600 35-200 175-1000 Typical 60 hertz Time-Power Curves are shown in figures 4 & 5 page 8. The curves are taken at maximum torque which occurs with the current leading the voltage by 30 degrees (within ± 4 ). 3.1 TRIP CIRCUIT The main contacts will safely close 30 amperes at 250 volts dc and the seal-in contacts of the indicating contactor switch will safely carry this current long enough to trip a circuit breaker. The indicating instantaneous trip contacts will safely close 30 amperes at 250 volts dc, and will carry this current long enough to trip a breaker. 3.2 TRIP CIRCUIT CONSTANTS Indicating Contactor Switch Coil. 4.0 SETTINGS (I L V LL ) ( 3 single phase watts) Taps 20-30 - 40-60 - 80-100 - 120 100-150 - 200-300 - 400-500 - 600 35-50 - 70-100 - 140-175 - 200 175-250 - 350-500 - 700-875 - 1000 Ampere Pickup Ohms dc Resistance 0.2 8.5 1.0 0.37 2.0 0.10 The watt tap and the time dial setting must be selected. The connector screw on the terminal plate above the time dial makes connections to various turns on the operating coil. By placing this screw in the various 2

CW POWER RELAY 41-241.31B terminal plate holes, the relay will respond to multiples of tap value watts in accordance with the various typical time-watts curves, ± 5%.! CAUTION Since the tap block connector screw carries operating current, be sure that the screw is turned tight. In order to avoid opening current transformer circuits when changing taps under load, the relay must be first removed from the case. Chassis operating shorting switches on the case will short the secondary of the current transformer. The taps should then be changed with the relay outside of the case and then re-inserted into the case. 4.1 OVERWATT APPLICATION The CW for three phase application has taps which represent the minimum balanced three phase watts divided by 3 that will cause the disc to move. Tap value is also voltamperes at which the disc will begin to move with current leading voltage applied to the relay by 30 degrees. When connected for watt sensing the relay current leads relay voltage by 30 degrees when the system current and line-to-neutral voltage are in phase. Assume: R C = ct ratio = 600:5 = 120 R V = vt ratio = 4200:120 = 35 P = power = 1000 primary kilowatts (3Ø) desired trip level Direct Solution: T P = -------------------- = --------------------------- 1, 000, 000 = 137.5 R C R V 3 120( 35) 3 Indirect Solution: I P P 1, 000, 000 = ---------------- = -------------------------- = 138.8 a primary 3 4160 3V LL I S = 138.8 120 = 1.157 a secondary V S = 4160 35 = 118.86 volts line-to-line T = I S V S = 1.157( 118.86) = 137.5 Use tap 150 (closest to 137.5) on 100-600 watt relay. P = 150 137.5( 1000) = 1091 kw actural Time dial 2 will give 2 second operation at 2182 kilowatts. See Figure 4, page 8. 4.2 MOTOR LOSS OF FIELD APPLICATION The usual setting of the CW relay for this application (Figure 7, page 10) is 20 watts, time dial 2 on the 20-120 watt relay. When, on loss of field, the motor power factor goes approximately 30 degrees lagging (watts and vars into the motor) and more, the contacts of the CW close after the time delay established by the time dial setting. In this application, the CW would operate during motor starting and a field breaker 41a switch may be used to prevent this by controlling the voltage circuit. This allows the motor to be accelerated, and the field breaker closed before the CW close after the time delay established by the time dial setting. Note that the use of field breaker 41a switch control, prevents loss of field detection on accidental field breaker opening. Other provisions must be incorporated to trip the controller when 41a is used and the field breaker opens following field application. If 41a is not used directly, it may drive a timer that closes the coil circuit when 41 closes and has time delay release when 41 opens. This same relay will detect loss of synchronism in the first slip cycle provided the slip frequency is sufficiently low that the CW current stays in the operate area long enough to produce operation. 4.3 INDICATING CONTACTOR SWITCH (ICS) There are no settings to make on the indicating contactors with (ICS). Close the main relay contacts and pass sufficient dc current, through the trip circuit to close the contacts of the ICS. This value of current should not be greater than the particular ICS nameplate rating. The indicator target should drop freely. Repeat above except pass 85% of ICS nameplate rating current. Contacts should not pickup and target should not drop. 5.0 INSTALLATION The relays should be mounted on switchboard pan- 3

41-241.31B CW POWER RELAY els or their equivalent in a location free from dirt, moisture, excessive vibration and heat. Mount the relay vertically by means of the four mounting holes on the flange for the semi-flush type FT case. The mounting screws may be utilized for grounding the relay. External toothed washers are provided for use in the locations shown on the outline and drilling plan to facilitate making a good electrical connection between the relay case, its mounting screws and the relay panel. Ground wires should be affixed to the mounting screws as required for poorly grounded or insulating panels. Other electrical connections may be made directly to the terminals by means of screws for steel panel mounting. For detail information on the FT case refer to I.L. 41-076 for semi-flush mounting. 6.0 ADJUSTMENT AND MAINTENANCE For an Acceptance Test use the following information as appropriate. The proper adjustments to insure correct operation of this relay have been made at the factory and should not be disturbed after receipt by the customer. If the adjustments have been changed, the relay taken apart for repairs, or if it is desired to check the adjustments at regular maintenance periods, the instructions below should be followed carefully. All contacts should be cleaned periodically. A contact burnisher Style Number 182A836H01 is recommended for this purpose. The use of abrasive material for cleaning contacts is not recommended, because of the danger of embedding small particles in the face of the soft silver and thus impairing the contact. 6.1 PRODUCT UNIT NOTE: A spring shield covers the reset spring of the product unit. To remove the spring shield, requires that the damping magnet be removed first. The screw connection holding the lead to the moving contact should be removed next. The second screw holding the moving contact assembly should then be loosened not removed.! CAUTION This screw terminates into a nut held captive beneath the molded block. If screw is removed, difficulty will be experienced in the re-assembly of the moving contact assembly.) Slide the spring shield outward and remove from relay. Tighten the screw holding the moving contact assembly to the molded block. 6.2 CONTACT The index mark on the movement frame will coincide with the 0 mark on the time dial when the stationary contact has moved through approximately one-half of its normal deflection. Therefore, with the stationary contact resting against the backstop, the index mark is offset to the right of the 0 mark by approximately.020. The placement of the various time dial positions in line with the index mark will give operating times as shown on the respective time-watt curves. 6.2.1 Minimum Trip Volt Amperes - Set the time dial to position 6. Using the lowest tap setting, alternately apply tap value volt amperes plus 3% and tap value volt amperes minus 3% with the current leading the voltage by 30. The moving contact should leave the backstop at tap value plus 3% and should return to the backstop at tap value minus 3%. The relay should be calibrated with 10 times tap value at the number six time dial position. Check several points on the typical time curves. Time curve calibration is affected by adjusting the position of the permanent magnet keeper. Note that with current leading voltage by 30 degrees the actual watts applied to the relay are.866 times tap value at pickup. 6.3 INDICATING CONTACTOR SWITCH (ICS) Initially adjust unit on the pedestal so that armature fingers do not touch the yoke in the reset position (viewed from top of switch between cover and frame). This can be done by loosening the mounting screw in the molded pedestal and moving the ICS in the downward position. a) Contact Wipe Adjust the stationary contact so that both stationary contacts make with the moving contacts simultaneously and wipe 1/64 to 3/64 when the armature is against the core. 4

CW POWER RELAY 41-241.31B b) Target Manually raise the moving contacts and check to see that the target drops at the same time as the contacts make or up to 1/16 ahead. The cover may be removed and the tap holding the target reformed slightly if necessary. However, care should be exercised so that the target will not drop with a slight jar. C) Pickup The unit should pickup at 98% rating and not pickup at 85% of rating. If necessary, the cover leaf springs may be adjusted. To lower the pickup current use a tweezer or similar tool and squeeze each leaf spring approximately equal by applying the tweezer between the leaf spring and the front surface of the cover, at the bottom of the lower window. If the pickup is low, the front cover must be removed and the leaf spring bent outward equally. 7.0 RENEWAL PARTS Repair work can be done most satisfactorily at the factory. However, interchangeable parts can be furnished to the customers who are equipped for doing repair work. When ordering parts always give the complete nameplate data. Current Coil Ratings: Range 20-120 Watt Range 35-200 Watt Range 100-600 Watt Range 175-1000 Watt Range Amperes Continuous 1 Sec 5 A 230 A 8 A 370 A Relay Range Potential Circuit Current Circuit Watts Voltage Voltamperes Current lags by Current Relay Tap Voltamperes Current lags by 20-120 100-600 120 120 17.9 17.9 60 60 5 amp. 5 amp. 20 100 16.2 5.4 78 77 35-200 175-1000 208 208 18.8 18.8 59 59 5 amp. 5 amp. 35 175 16.2 5.4 78 77 5

41-241.31B CW POWER RELAY PHASE SHIFT RESISTOR WATT TAPS DAMPING MAGNET ICS PHOTO Figure 1: Front View of Type CW Power Relay without Case (photo) Sub 4 3518A63 Figure 2: Internal Schematic of the Type CW Relay in Type FT-11 case 6

CW POWER RELAY 41-241.31B Sub 1 849A304 Figure 3: Current and Voltage Phasors at System Unity Power Factor Applied to Type CW relay 7

41-241.31B CW POWER RELAY Sub 1 3536A52 Figure 4: Typical 60 Hertz Time Curves of the 21-120 and the 35-200 watt type CW Relay. Sub 1 3536A53 Figure 5: Typical 60 Hertz Time Curves of the 100-600 and 175-1000 watt type CW Relay. 8

CW POWER RELAY 41-241.31B * Sub 6 184A811 Figure 6: External Schematic of Three Type CW Relays on a Three-Phase System Note: For Balanced Three-Phase Conditions only One CW Relay is required. 9

41-241.31B CW POWER RELAY Sub 3 774B831 Figure 7: External Schematic of a Three-Phase Connection of One CW Relay for Loss of Field Protection 10

CW POWER RELAY 41-241.31B 125 VOLT TEST SOURCE ROTATION A, B, C TYPE CW RELAY (FRONT VIEW) PHASE SHIFTER A ICS PHASE ANGLE METER V + + I A.C.T. ICS CW CW CW SWITCH RHEOSTAT VARIABLE AUTO - TRANSFORMER 1 2 3 4 5 7 6 + + 9 8 10 V NOTE: MAXIMUM TORQUE ANGLE IN THE TRIPPING DIRECTION OCCURS WHEN THE CURRENT LEADS THE VOLTAGE BY 30 DEGREES WITH CONNECTIONS AS SHOWN. Sub 3 849A303 Figure 8: Diagram of Test Connections for Type CW Relay in FT-11 Case 11