Authorised Distributors:- ASH & ALAIN INDIA PVT LTD S-, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-(India) Tel : -7977 Fax : -7977 E-mail : sales@ashalain.com Sensor Four-Input-Channel Sensor with Versatile Features and Functions Be sure to read Safety Precautions on page 99. Ordering range Output configuration Model to kpa - Positive pressure to MPa - Linear output: to V Negative pressure to kpa -N Compound pressure to kpa -N * * -N is only -channel pressure sensor controller. E8-C can be used. For more details, please refer to E8 catalogue. E8F E8M range Output configuration Model Minute pressure Differential pressure from to, Pa between positive E8M-A-S differential and negative ports Linear output: to V Positive pressure to MPa E8M- Negative pressure to kpa E8M-N Controller Power supply voltage Output configuration Number of sensor inputs Model VDC NPN open collector CH E8M-MP8 Note:. -@@ is -channel pressure sensor controller. E8-C needs to be prepared. For more details, please refer to E8 catalogue. Please refer to Sensor and Controller section of the following page. 88
Accessories (Order Separately) Sensor I/O Connectors Applicable model Appearance Model Specifications Unit Remarks E8M E89-M-S * E89-M-S -pin connector with -m-long cable -pin connector with -m-long cable Provided with one XNA- E-CON Connector. E89-M- -conductor, -m-long cable with connectors on both ends Cutting/extension is not possible. * E8M-A does not require the Sensor I/O Connector. Pin Controller Connector Appearance Model Applicable wire size (mm ) Quantity Minimum order unit Remarks Note: Orders are accepted in multiples of the minimum order unit. Power and Output Connector Adapter XNA-.8 to. Model Specifications Quantity E89-M-S 8-pin connector with -m cable Model Quantity Remarks Y9F-7-S One unit is provided with E8M-MP8. Note: Orders are accepted in multiples of the minimum order unit. One unit is provided with each E89-M and E89-M. Hard Cover Model Y9A--S Adapter for @8 Panel Hole Model Y9F-8-S Sensor and Controller Combinations Use the Controllers in the following combinations. The E89-M/M is required when using the Sensor as a single unit. Model E89-M-S E89-M-S E8M-MP8 E89-M-S E8-C E89-M- - No Yes Yes Yes Yes Yes - No Yes Yes Yes Yes Yes -N No Yes Yes Yes Yes Yes -N No No No No Yes Yes E8M-A No No Yes Yes No No E8M- Yes No Yes Yes No No E8M-N Yes No Yes Yes No No Yes: Required No: Not required Sensor and Controller Connection E8F E8M-A-S E8M-MP8 -@@ E8M-/N Sensor input Controller output E89-M-S -@@ E89-M- E8-C E89-M/M 89
Ratings and Specifications Item Model - - -N -N Power supply voltage VDC ±%, ripple (p-p) of % max. Current consumption ma max. type Gauge pressure Applicable fluid Non-corrosive gas and non-flammable gas range to kpa to MPa to kpa to kpa Withstand pressure kpa. MPa kpa Linearity ±% F.S. max. Hysteresis ±% F.S. max. Linear output Voltage output: to V with an output impedance of kω Protection circuits Reverse polarity protection, load short-circuit protection Ambient temperature Operating: to C Storage: to 6 C (with no icing) Ambient humidity Operating/Storage: % to 8% (with no condensation) Temperature influence ±.% F.S./ C max. Voltage influence ±% F.S. max. Insulation resistance MΩ min. (at VDC) between current-carrying parts and case Dielectric strength, VAC for minute Vibration resistance Destruction: to Hz,.-mm single amplitude or m/s, times each for 8 min in X, Y and Z directions Shock resistance Destruction: m/s times each in X, Y and Z directions Degree of protection IP (IEC69) port R (PT) /8 taper screw and M female screw Connection method Connector Weight (packed state) Approx. 6 g Material port Aluminum Accessories Instruction manual E8F 9
E8M Item Model E8M-A-S E8M- E8M-N Power supply voltage VDC ±%, ripple (p-p) of % max. Current consumption ma max. type Differential pressure Gauge pressure Applicable fluid Non-corrosive gas and non-flammable gas range Differential pressure from to, Pa between positive and to MPa to kpa negative ports Withstand pressure Differential pressure from to, Pa between positive and. MPa kpa negative ports * Accuracy ±% F.S. max. ±% F.S. max. Linearity ±% F.S. max. Hysteresis ±% F.S. max. Linear output Voltage output: to V with an output impedance of kω Protection circuits Reverse polarity protection, load short-circuit protection Ambient temperature Operating: to C Storage: to C (with no icing) Ambient humidity Operating/Storage: % to 8% (with no condensation) Temperature influence ±.% F.S./ C max. ±.% F.S./ C max. Voltage influence ±% F.S. max. Insulation resistance MΩ min. (at VDC) between current-carrying parts and case Dielectric strength, VAC for minute Vibration resistance Destruction: to Hz,.7-mm single amplitude or m/s, times each for 8 min in X, Y and Z directions Shock resistance Destruction: m/s times each in X, Y and Z directions Degree of protection IP (IEC69) port M female screw R (PT) /8 and M female screw M male screw Connection method Pre-wired cable (standard length: m) Connector Weight (packed state) Approx. g Approx. g Approx. g Material port Stainless steel (SUS) Stainless steel (SUS) Case ABS Aluminum, polyether sulfonic resin Accessories Pin Controller Connector, instruction manual Instruction manual * The absolute pressure value of each port is kpa. Measurement method E8M-A generator mm E8F 9
Controller E8F Item Model E8M-MP8 Connectable Sensor Power supply voltage Current consumption Sensor power supply Sensor input (through -pin Input one-touch connector) Comparative output Output Automatic shift input Measurement value Message Indicators and setting Measurement channel Comparative output Response speed Set resolution Display accuracy Protection circuits Ambient temperature Ambient humidity Temperature influence Voltage influence Insulation resistance Dielectric strength Vibration resistance Shock resistance Degree of protection Connection method Weight (packed state) Accessories E8M-A-S * Differential pressure from to, Pa between positive and negative ports * differentials are displayed with a minus ( ) sign. - ( to kpa) - E8M- ( to MPa) VDC ±%, ripple (p-p) of % max. ma max. (Sensor section consumed electric current ma / ch included) Supplied from the Controller, VDC±% ( ma max. for each channel) Input voltage range: to VDC (Input impedance 8 kω) -N E8M-N ( to kpa) NPN open collector Maximum load current: 8 ma max. Load voltage: VDC max. Residual voltage:.8 V max. with a flow current of ma,. V max. with a flow current of 6 ma NO or NC (selectable) independent output in hysteresis or window mode (selectable) on each channel Non voltage input (contact point or non-contact point), input for more than ms column LED indicator (orange color) (character height: 9 mm) column LED indicator (orange color) (character height: 9 mm) column LED indicator (red color) (character height: mm) LED indicator (red color) that is lit when Tr is turned ON ms max. (When chattering prevention function is enabled, it changes to either ms, 6 ms or 6 ms) ±.% F.S. max. ±.% F.S. max. ± digit (ambient temperature C) Reverse polarity protection, load short-circuit protection Operating: to C Storage: to 6 C (with no icing) Operating/Storage: % to 8% (with no condensation) ±.% F.S. max. (at C) ±% F.S. max. MΩ min. (at VDC) between current-carrying parts and case, VAC for min Destruction: to Hz,.7-mm single amplitude or m/s, times each for 8 min in X, Y and Z directions Destruction: m/s times each in X, Y and Z directions IP6 IEC69 standard, Front section only: IP6 (at the time of panel installation), others: IP Panel mounting Power supply and output: 8-pin Terminal Sensor I/O: -pin e-con Connector Approx. g (Accessories not included) Instruction manual, adapter and waterproof gasket 9
Engineering Data (Typical) Linear Output Voltage vs. - -- -N-N Linear output voltage (V) Linear output voltage (V) Linear output voltage (V) 6 8 6 8, 6 8 E8M-A-S (kpa) -N (kpa) (kpa) Linear output voltage (V) Linear output voltage (V) 6 8, Differential pressure (Pa) between positive and negative ports 6 6 (kpa) E8F 9
Output Linearity - -- -N-N Linearity deviation (%FS) Linearity deviation (%FS) - E8M- Linearity deviation (%FS) -N E8M-N 6 8 (kpa) E8M-A-S 6 8, (kpa) -N 6 8 (kpa) Linearity deviation (%FS) Linearity deviation (%FS) 6 8, Differential pressure (Pa) between positive and negative ports 6 6 (kpa) E8F 9
Linear Output Fluctuation vs. Voltage - - -N................................ Voltage (V)..... Voltage (V) E8M-A-S E8M- E8M-N..................... Voltage (V)................ Voltage (V) E8M-N..... Voltage (V)..... Voltage (V)....... (negative) (positive)....... Voltage (V) E8F 9
Linear Output Fluctuation vs. Temperature - - -N 6 6 6 Temperature ( C) Temperature ( C) E8M-A-S E8M- E8M-N Temperature ( C) -N Temperature ( C) Temperature ( C) Temperature ( C) Linear output fluctuation (%FS) (negative) (positive) 6 E8F Temperature ( C) 96
I/O Circuit Diagrams Output configuration Model Output circuit Connector Brown +V - - -N -N Sensor main circuit Black (linear output) Load Blue V Brown +V to V linear output E8M-A-S Sensor main circuit Power indicator (green) Pink * / V Input Black (linear output) Load Blue V Controller E8M- E8M-N Sensor main circuit Power indicator (green) Connector Brown +V Pink * / V Input Black (linear output) Load Blue V Output configuration Model Output circuit NPN output E8M-MP8 Sensor Sensor Sensor Sensor Bk Be (P) Bn Bk Be (P) Bn Bk Be (P) Bn Bk Be (P) Bn Main Circuit Note: Bk-Black, Be-Blue, P-Pink, Bn-Brown V brown Auto-shift input yellow CH_OUT black CH_OUT white CH_OUT gray CH_OUT orange CH_OUT pink V blue) * Input for lighting the power supply indicator. V supplied: lit, V: not lit Load Load Load Load Load DCV Note: The wire colors shown on the left are the wire colors of E89-M-S (Controller power supply/output connector cables). E8F 97
Nomenclature Sensor Controller E8M-MP8 LCD Indicator (orange) Unit Indicator (orange) Switch Output Indicator (red) Channel Indicator (red) Button Button Button Switch output indicator (red): Output OUT (CH~ ), OUT (only CH) are lit up when ON LCD indicator (orange): Present pressure, state of setting mode, unit, and error code are indicated. Button: The values and ON/OFF specification of mode are increased by pressing the Up button. Button: The values and ON/OFF specification of mode are decreased by pressing the Down button. Button: Used for modification of each mode and selection of specification. Unit indicator (orange): The unit, which is selected, is lit up. Available SI units: MPa and kpa. Channel indicator (red): The selected channel (CH ~ CH) is lit up. Accessories Accessory Panel Mount Adapter.............. Y9F-7-S (M 8L ( units)) Mounting Options Power Source Output Connector Cable ( m).... E89-M-S Sensor I/O Connector Power Source/ Output Connector Cable E8F Front Wire Protector........................Y9A--S @8 Conversion Adapter..................... Y9F-8-S (For KC Series panel size, install E8M-MP8 Adapter) Waterproof Gasket (accessory) Front Wire Protector Panel Mount Adapter (accessory) @8 Conversion Adapter 98
Safety Precautions Refer to Warranty and Limitations of Liability on page F-. WARNING This product is not designed or rated for ensuring safety of persons. Do not use it for such purpose. Precautions for Correct Use Do not use this product in atmospheres or environments that exceed product ratings. Installation Connecting and Locking the Sensor I/O Connector (E89-M) ()Hold both ends of the female connector connected to the Sensor I/O Connector so that the protrusion on the female connector faces upward, orientate the hole in the male connector on the Sensor upwards, and insert the female connector into the hole until the protrusion clicks in. ()A lock cover is slid through the Sensor I/O Connector to prevent it from coming free due to vibration or shock. Insert the lock cover facing in the correct direction (a) as shown in the following figure, and rotate it clockwise (b) until it clicks in. Lock cover (a) ()To unlock the connector, rotate the lock cover counterclockwise until it clicks, then pull it towards you. To disconnect the connector, hold both ends of the connector, then pull it towards you. (b) Installations -@@- ()The pressure-introducing section (aluminum for, SUS for E8M) is fixed with tapered R(PT)/8 male screws and M female screws. ()When using tapered screws, use tapered Rc(PT)/8 female screws. Wrap the tapered R(PT)/8 male screws with sealing tape to prevent any leakage. Tighten the male screws to a torque no more than.9 N m. ()Tighten M female screws to a torque no more than to. N m. ()When tightening a screw, hold by its hexagonal head, not by its body. E8M-N ()The pressure port (SUS) is fixed with M male screws. ()Tighten male screws to a torque no more than to. N m. ()When tightening a male screw, hold by its hexagonal head, not by its body. E8M-A ()The pressure port (SUS) is fixed with M female screws (7 mm deep). ()Tighten screws for the pressure port to a torque no more than to. N m. ()M female screws are used for the product mounting sections. ()When mounting the product, tighten the screws while holding a metal part of the product, not a resin part. ()Tighten the product mounting screws to a torque no more than. N m. (6)If the positive pressure section is released and positive pressure is applied to the negative pressure section, a positive pressure may be displayed. E8M-MP8 ()Install the Sensor horizontally. ()The recommended panel thickness is. to 8 mm. ()Do not install the Sensor in an environment subject to strong vibration or shock. ()Do not install the Sensor under dusty conditions. ()Do not install the Sensor in an environment subject to corrosive gases, particularly sulfide and ammonia gases. (6)Do not install the Sensor near equipment that generates strong high-frequency noise such as high-frequency welders or sewing machines. Lock Unlock Lock cover Note: Forcibly pulling the cable to disconnect the connector may damage the pressure-welded portion. Be sure to hold both ends of the connector when disconnecting it. E8F 99
Installation Connector Assembly Procedure. Processing the Sensor I/O Connector Cable End ()The cable end is semi-stripped. Semi-stripped.The removable point is inserted with negative bar, and the lever is pulled back lightly. The control lever returns when a click sound is heard. Lever (white) ()Cut the ends as shown in the illustration on the right, and do not peel the shield.. Lastly, verify the below: The lever is being pulled back lightly. Verify again Point (). (There is slight resistance when the electric wire is pulled lightly.). Fitting Controller Conductors to Cable Connector Cover ()Terminal numbers are engraved on the cover. Refer to the following and be sure that these terminal numbers correspond to the wire colors correctly. Preparation of Electric Wire The coating of the wire is cut and peeled, showing 7 to 8 mm of stranded wire. Twirl the stranded wire and inserted into the side with "STRIP GAUGE" indicated on it. Connection Procedure. Press the negative bar, push the stranded wire in and lock it. mm min. Model E89-M-S E89-M-S Terminal No. I/O code Black (Output) --- Pink (LED lighting input) Brown (Vcc) Black (IN: to V) 7 to 8 mm small screwdriver. The open electric wire is inserted to the inner part. The coating section of the wire is also entered into the electric line insertion opening. Please verify that the lead wire section point passes the wiring section. Connected Cancellation Procedure. The control lever is pushed in and electric wire is being pulled out.. After completion of connection cancellation, please ensure that the control lever is returned to its original position. If wiring job is to be continued, please do not return the control lever. Lever (white) s ()Do not use the Sensor in an environment subject to corrosive or combustible gases. ()Do not use the Sensor alongside a high-tension voltage line or power line. ()Do not expose the Sensor to water. ()Be sure to use the Sensor under the rated pressure. ()Do not insert any wire into the pressure port. Doing so may damage the pressure elements and cause a malfunction. (6)Do not apply any tensile strength in excess of N for, N for E8M to the cables or connectors. (7)Compressor oil and air-borne water may form droplets at the pressure receiving section of the Sensor. Remove the oil and water using an air filter to prevent damage to Sensor elements. (8)Do not pull the cables. When removing the connectors for external connection, be sure to use the lock lever. E8F Connection point Wire insertion point
Dimensions (Unit: mm) - - -N -N M (depth: 7. mm) R (PT)/8 () (8.8) port Connector: DFB-P-.V () by Hirose Electric. Connection with E89-M Sensor I/O Connector. 8.... dia. (.) 9.7 E8M-A-S 8 8. 9 M pressure port (Positive) (depth: 7 mm) Two, M mounting holes.9 9.-dia vinyl-insulated round cable (./. dia.) with conductors, Standard length: m 6 9 M pressure port (Negative) (depth: 7 mm). Power indicator (green) 8. Note: One XNA- is supplied together with E8M-A-S. 8 E8M- M8 hexagonal nut R/8 M. 7. dia..6 Connection with E89-M-S Sensor I/O Connector port. 6.7 (7.) Power indicator (green).9 dia Connector: BB-XASK 9. by JST Mfg. Co., Ltd. (8.) () E8M-N M hexagonal nut M. 7. dia..6 Connection with E89-M-S Sensor I/O Connector E8F 7 port 7 6.7 () Power indicator (green).9 dia. Connector: BB-XASK 9. by JST Mfg. Co., Ltd. (8.) ()
Controller E8M-MP8 7 @.. 9...9 ------------------------------------------- @ @. 6. 6.8 Front wire protector Panel mount adapter Power source/output connector 8-pin Waterproof gasket Sensor I/O Connector -pin Panel Cut Dimensions @7... min. Accessories (Order Separately) Sensor I/O Connectors min. The recommended panel thickness is. to 8 mm. For the E8M Only E89-M-S.9-dia vinyl-insulated round cable (./.9 dia.) with conductors, Standard length: m Note: One XS8A- is provided with the E89-M., For the Only E89-M-S.9-dia vinyl-insulated round cable (./.9 dia.) with conductors, Standard length: m 8.9.., Note: One XS8A- is provided with the E89-M. E8F For /E8-C Connection E89-M-.9-dia robot cable (./. dia.) with conductors, Standard length: m. 8.9 - + ±, + ± ±.
Power Source/Output Connector Cable E89-M-S Pin Controller Connector XNA- (Pitch) 6.....,.7±. dia. Cable, Black ± ± ± 7. (Strip Gauge) 7.6 8 6.6..8. (Inner diameter).6 (Outer diameter) Note: One unit is provided with the E89-M-S or E89-M-S.. Adapter Y9F-7-S 7 7.8?. Front Wire Protector Y9A--S @. @6. Front.9 6. Note: One unit is provided with E8M-MP8. @8 Conversion Adapter Y9F-8-S?8?7. E8F Authorised Distributors:- ASH & ALAIN INDIA PVT LTD S-, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-(India) Tel : -7977 Fax : -7977 E-mail : sales@ashalain.com