OMNI EXPRESS PORTABLE PATIENT MONITOR

Similar documents
INFINIUM PRODUCT CATALOG

Infinity. Vista Patient Monitor. Because you care

RELIABLE: ALWAYS, EVERYWHERE

Precess ACCESSORY GUIDE REV B * * Model 3160 REF April 2011

INSTRUMENT TRAY Instrument trays may be placed at six convenient locations.

DEFIBRILLATOR, MONITOR RECORDER TOC

FEATURES AND BENEFITS

T-Sense _ 660. Optical Torque Measuring Systems. Product Bulletin

Angio imaging - with stress support radiology

LIFEPAK 15 MONITOR /DEFIBRILLATOR

ACCESSORIES LIFEPAK 12 DEFIBRILLATOR/MONITOR. for use with the. Genuine accessories from Physio-Control

PRODUCT BROCHURE LIFEPAK 15 MONITOR/DEFIBRILLATOR. For Emergency Medical Services

FOCUS - ON - PATIENTS. corpuls 1. Medical Technology. Made in Germany

Est Battery Data Logger BDL3000

PRODUCT BROCHURE LIFEPAK 15 MONITOR/DEFIBRILLATOR. For Emergency Medical Services

ProSim 4. Vital Signs Simulator. Getting Started

PRODUCT BROCHURE LIFEPAK 15 MONITOR/DEFIBRILLATOR. For Emergency Medical Services

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM

Belt Scales Table of Contents

R Series. Taking Resuscitation to Heart

HK Equipment CZD Brake tester Max. weight Size Roller size Measure range Error Rated use condition: CCH Sideslip tester 10,000kg (15,000kg) 3990 x 840

EMS Guide M C S. January 2014 ECHANICAL IRCULATORY UPPORT O RGANIZATION

ACCESSORIES MONITOR/ DEFIBRILLATOR. for use with the. Genuine accessories from Physio-Control

Simple. Smart. Ready. Whatever your needs, whoever responds.

ACCESSORIES LIFEPAK 12 DEFIBRILLATOR/MONITOR. Genuine accessories from Physio-Control

SonoMeter 30 Energy Meters

PLC-3000 zfa01. Portable Fluid Analysis. Global Filtration Technology

Sola/Hevi-Duty S3K Series Mini-Tower UPS

Pain Management Solutions

VersiVision - High Definition Fiber Optic Video

Testing Instrumentation Gasboard 5020 for exhaust gases from petrol or LPG engines

Battery Monitoring Why Technology Matters. Mats Karlstrom V.P. Sales & Marketing, Alber

Level and Flow Measurement. Sludge Finder 2

T-Sense. Optical Torque Measuring systems. Product Bulletin TO BE REALLY SURE

PRODUCTS AND ACCESSORIES CATALOGUE 2004

WOMEN OWNED SMALL BUSINESS

MIMO Zen Series. Dual Band 3x3 MIMO ac/b/g/n High Bandwidth Indoor Access Point 700MHz CPU / 2.4GHz at 450Mbps / 5GHz at 1300Mbps

ACCESSORIES BROCHURE LIFEPAK 12 DEFIBRILLATOR/MONITOR. Genuine Accessories from Physio-Control

SonoMeter 30 Energy Meters

BRAVER UPS. (Uninterruptible Power System) User s Manual

Physio-Control Accessories. Product Code Description Unit #/unit Price LIFEPAK CR Plus Hard shell carry case EA 1 $ 210.

Ventilation Control. Ventilation Control 12

CROSSROADS VETERINARY HOSPITAL

BCM Electrocardiograph (Ver 1.2) Operation Manual

ACCESSORIES BROCHURE. LIFEPAK 20/20e. DEFIBRILLATOR/MONITOR with CodeManagement Module. Genuine Accessories from Physio-Control

Welch Allyn Spot Vital Signs

INTECH Micro 2300-RTD6

Reliability that s. simply portable

The mobility, integration & power to help improve patient care.

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

CHAIN WEAR ANALYSIS WITH LUBECON

RALF At a glance. Bioengineering RALF essentials. General

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

AVL FUEL BALANCE & FUEL TEMPERATURE CONTROL

Atlas 5. Instruction Manual. Handheld Indoor Air Quality Monitor. Measures CO2, Temperature and Humidity DISTRIBUTED BY

HK Equipment CZD Brake tester Max. weight Size Roller size Measure range Error Rated use condition: CCH Sideslip tester 10,000kg (15,000kg) 3990 x 840

Compression/Tension Testing Machines

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

MIMO Zen Series. Dual Band 3x3 MIMO ac/b/g/n High Bandwidth Indoor Access Point 700MHz CPU / 2.4GHz at 450Mbps / 5GHz at 1300Mbps

TruSystem 7000 One table without limits

Closing Sale Prices. AmigoBot Pioneer 3-DX Pioneer 3-AT Pioneer LX Pioneer Manipulator PeopleBot PowerBot Seekur Jr

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

MiniLab EL Series for High Performance Engine Development and Maintenance

MOBILE IMAGING SYSTEM

Benchmark. Pulsatile Pump PD Medical Device Testing & Equipment Simulation Platforms Silicone Vessels

Cadex C8000. Advanced programmable battery testing system

CONTAMINATION CONTROL FOR LIFE SCIENCE APPLICATIONS

SARASOTA MEMORIAL HOSPITAL DEPARTMENT POLICY

BODYGUARD 323 AMBULATORY INFUSION PUMP

Current Automation Catalogue

DMT PERFORMING UNDER PRESSURE DMT. Pressure Scanner Features. Applications. Description 1/7

Uninterruptible (ATX) Switching Power Supply. MODEL eups-350

MIMO Zen Series. Dual Band 3x3 MIMO ac/b/g/n High Bandwidth Indoor Access Point 775MHz CPU / 2.4GHz at 450Mbps / 5GHz at 1300Mbps (Wave-2)

CP900EPFCLCD User s Manual K

SHOCK ABSORBER/DAMPER TESTING MACHINE

MIMO Zen Series. Dual Band 2x2 MIMO ac/b/g/n Enterprise Indoor Access Point 560MHz CPU / 2.4GHz at 300Mbps / 5GHz at 867Mbps

APPEFNDIX 1 SPECIFICATIONS OF THE TEST ENGINE

PRELIMINARY COMPEX SYSTEMS

Technical Specifications

ALIANT ULTRALIGHT BATTERY is a product by ELSA Solutions S.r.l

EMERSON CLIMATE TECHNOLOGIES-EX

Liebert PowerSure PSI UPS

Product Information. Mflow extrusion plastometer

POWERSPORTS DYNAMOMETER HARDWARE AND SOFTWARE

Industrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized

SOLAR SMART. 12/24V 20Amp MPPT Solar Charge controller with Ethernet

PR1000ELCD / PR1500ELCD User s Manual

MX1S Matrix Converter

Installation and Operation Manual. RTA Series 1KVA to 3KVA Models Uninterruptible Power Systems (UPS)

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

Language specific user manuals are available on

SWII Users Manual. Intercomp Co County Road 116 Minneapolis, MN (763) Fax

Model 7400 OPERATOR MANUAL

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

500/800. CalTrak. High Accuracy Modular Primary Standard Gas Flow Calibrator Cal Labs & Industry. FEATURES DESCRIPTION

Power+ CLASSIC. 20/30 kva, 3x208 Vac

MB3000. Versatile FT-IR analyzer designed for your industry The most reliable FT-IR, the lowest cost of ownership.

Multi Point Station Series

Transcription:

OMNI EXPRESS PORTABLE PATIENT MONITOR

OMNI EXPRESS Intuitive Designed for a fast paced work environment, the Infinium Omni Express patient monitor offers an extremely simple and adaptable user interface. Patient information along with vital sign settings can be quickly modified to meet the needs of a patient s changing condition. The Omni Express offers a high resolution 7 inch touch screen to optimize the speed of patient care. The user can therefore make quick screen adjustments, set default settings, alarm limits, and manage up to 72 hours of detailed patient data. Upgradable From the general floor to high acuity surgeries, the Infinium Omni Express series patient monitors are designed to fit-in and move amongst many patient care areas. The Omni Express offers standard measurements of: non-invasive blood pressure, ECG with arrhythmia detection, Masimo SET SpO2, Temperature, and Respiration rate. Masimo SET (Signal Extraction Technology ) SpO2 provides industry standard Measure-through Motion and Low Perfusion Pulse Oximetry to Infinium patient monitors. End-tidal CO2 can added on-site by simply attaching our plug in modules. This field upgradability can allow the user to customize the monitor s acuity level while the patient s condition changes. If desired, the user can move from a basic vital signs monitor, to a continuous bed side monitor, to an operating room monitor while keeping the patient on a single monitor at all times. Connective The Omni Express offers several connective solutions to network multiple monitors and/or manage patient data on an electronic medical records platform or a HL7 based hospital information system. The Omni Express patient monitor offers Ethernet and RS-232 connections with an open source communication protocol. Infinium offers 2 levels of networking and connectivity. The Omni Express is HL7 compliant. The HL7 network protocol will allow for all patient information and vital sign trends to be transferred and stored on a hospital information system. For non-hl7 medical facilities, there is the Infinium Omniview central station which allows the real time remote monitoring and network of up to 32 Omni patient monitors. The Omniview archives full disclosure of all patient vital sign trends. The patient data from the Omniview can be very simply saved, stored, printed, and, transferred.

A Field Upgradable Operating Room Solution A MONITOR THAT CAN GROW WITH YOU... Whether it be a basic outpatient procedure or a high acuity cardiac surgery the Omni Express can be upgraded and custom tailored on-site by the user. The Omni Express is preconfigured with non-invasive blood pressure, 3/5 ECG with arrhythmia detection, impedance respiration, SpO2, and temperature. More advanced readings of End-tidal CO2 can be activated by the user at anytime. Capnography & Anesthetic Agent Measurement plug in Module: The Infinium CO2 module s a field upgradable plug in module that can measure End-tidal CO2 alone Both mainstream and sidestream modules are available for Endtidal CO2 and agent measurement Our CO2 utilizes a low flow (50ml/min) sidestream method that allows use for intubated and non-intubated applications. Our sample line connection incorporates filter cells to eliminate the potential of cross contamination Simple connection sample lines allows Infinium CO2 to be one of the industry's lowest cost per patient End-tidal CO2 systems

OMNIVIEW Central Station SIMPLICITY IN CONNECTIVITY: The Omniview central station allows the wireless or hard-wired measurement for a network of up to 32 Omni patient monitors. The Omniview archives full disclosure of all patient information and vital sign trends. In real time the Omniview displays the patient s numeric vital signs along with waveforms. The patient data from the Omniview can transferred to a EMR as a supplement to the patient s file or integrated into a hospital information system. The Omniview gives a real time display of all patient vital signs: Heart rate, Last BP reading, SpO2, Temp, EtCO2 and Respiration rate with waveforms.

Mounting Solutions A RELIABLE CONNECTION Several mounting systems are available for the Omni series patient monitors. ROLLING STAND Height and tilt adjustable with a large wheel base allows for smooth and stable mobility. n Quick release slide mount n Accessory basket n Medical grade steel construction n Lockable wheels WALL MOUNTS Height and tilt adjustable wall mounts offer. n Quick release of monitor n Medical grade construction n Adaptable to anesthesia machines n Adaptable to most wall rail systems

OMNIVIEW CENTRAL MONITORING SYSTEM SPECIFICATIONS: MAIN FRAME Power Supply AC100-240V 6A/3A Basic Configuration 20 or larger color display Intel Pentium IV2.0G CPU Windows XP professional operating system 512MB RAM 80GB Fixed Disk drive PERFORMANCE Display Size: color TFT display 20 or larger Number of display: 1 or 2 sets (optional) Resolution: 1280 x 1024 Waveform ECG (I, II, III, avr, avl, avf, V1-V6) PLETH, RESP, CO2, IBP, Multi-gas Parameter HR, ST, NIBP, IBP, SpO2, PR, RR, TEMP, EtCO2, Multi-gas Indicator Up to 32-waveform presentation 12.5mm/s, 25.0mm/s, 50.0mm/s user-adjustable sweep speed Alarm sound Alarm High and Low limits alarm Audiable and visual alarm Record Type 8 seconds real-time recording Freeze waveform recording Trend data recording Alarm strip recording Printer External Laser Printer View Up 64 waveforms for up to 32 bedside monitors (8 monitors per screen) All waveform presentation for single patient 48 hours of trend display for all parameters Multi-leads ECG waveform display Waveform freeze Wireless Networking Industry standard 802.11b/g WLAN Connected bedside number: up to 16 bedside monitors Review 240 hours trend review for each bedside monitor 720 items parameters alarm review for each bedside monitor 720 NIBP measurements review 72 hours of 32 channels full-disclosure waveforms store and review Connection methods Wireless via transmitter Hardwired via ethernet Hardwired via RS-232 OMNI EXPRESS TECHNICAL SPECIFICATIONS: PEFORMANCE SPECIFICATIONS Display: 7 color TFT Resolution: 1024 860 Trace: 2 or 3 waveforms Waveforms ECG(I, II, III, avr, avl, avf, V1-V6), PLETH, RESP, ETCO2 Indicator: Alarm indicator Power indicator QRS beep and alarm sound Trend time: From 30 minutes to 72 hours ECG Input: 5 lead or 3 lead ECG cable and standard AAMI line for connection Lead Choice: I, II, III, avr, avf, avl, V Gain Choice: 0.5, 1.0, 2.0 CMRR (common mode rejection ratio): >100 db at 50 Hz or 60 Hz Frequency Characteristic: 0.67~40 Hz (+3dB attenuation) ECG Waveforms: 7 channels Sweep Speed: 12.5, 25 and 50 mm/s HR Display Range: 30~300bpm Accuracy: ±1bpm or ±1%, whichever is greater Alarm Limit Range Upper limit: 80~400bpm Lower limit: 20~150bpm RESPIRATION Measure Method: RA-LL impedance Range: 0~120 rpm Accuracy: ±3 rpm Alarm Upper-lower Limit: Upper limit: 6~120 rpm, Lower limit: 3~120 rpm Sweep Speed: 12.5 and 25mm/s NIBP Measuring Technology: Automatic oscillating measurement Cuff Inflating: <30s (0~300 mmhg, standard adult cuff) Measuring Period: AVE<40s Mode: Manual, Auto, STAT Measuring Interval in AUTO Mode: 2 min~4 hrs Pulse Rate Range: 30 bpm~250 bpm Measuring Range: Adult/Pediatric Mode SYS 40~250 (mmhg) DIA 15!200 (mmhg) Neonatal Mode SYS 40!135 (mmhg) DIA 15!100 (mmhg) Resolution: 1mmHg Pressure Accuracy: Maximum Mean error: ±5mmHg Maximum Standard deviation: 8mmHg Overpressure Protection: Adult Mode 280(mmHg) Neonatal Mode 150 (mmhg) Alarm Limit: SYS 50~240 mmhg DIA 15~180 mmhg TEMPERATURE Range: 25~50 (ºC) Accuracy: ± 0.2 ºC (25.0~34.9 ºC) ± 0.1 ºC (35.0~39.9 ºC) ± 0.2 ºC (40.0~44.9 ºC) ± 0.3 ºC (45.0~50.0 ºC) Display Resolution: 0.1 ºC Alarm Upper-lower Limit: Upper limit 0~50 ºC Lower limit 0~50 ºC Channel: 1 channels Alarm Limit: 10~50 (ºC) Masimo SET Pulse Oximetry (standard) SpO2 Measurement range: 0% to 100% Resolution: 1% Accuracy: Accuracy: 70% to 100%, +/-2%, Adult/ Pediatric, Non-motion conditions 70% to 100%, +/-3%, Neonate, Nonmotion conditions 70% to 100%, +/-3%, Adult/ Pediatric/Infant/Neonate, Motion conditions 70% to 100%, +/-2%, Adult/ Pediatric/Infant/Neonate, Low perfusion conditions Averaging time: 2~4 sec, 4~6 sec, 8 sec, 10 sec, 12 Sensitivity settings: selectable) Pulse Rate Measurement range: Accuracy: Resolution: Perfusion Index (PI) Measurement range: 0.02 20% Any other SpO2 (optional) sec, 14 sec, 16 sec (user selectable) Normal, Maximum, APOD (user 25 to 240 bpm +/-3 bpm, Adult/Pediatric/Infant/ Neonate, Non-motion conditions 5 bpm, Adult/Pediatric/Infant/ Neonate, motion conditions 1 bpm EtCO2 (OPTION) Mode of Sampling: Sidestream or Mainstream Principle of Operation: Non-dispersive infrared (NDIR) single beam optics, dual wavelength, no moving parts. CO2 Measurement Range: 0 to 150 mmhg (0 to 19.7%, 0 to 20 kpa) CO2 Calculation Method: BTPS (Body Temperature Pressure Saturated) CO2 Resolution: 0.1mmHg (0-69mmHg), 0.25mmHg (70-150mmHg) CO2 Accuracy: 0~40 mmhg ± 2 mmhg 41~70 mmhg ± 5% of reading 71~100 mmhg ± 8% of reading 101~150 mmhg ± 10% of reading Above 80 breath per minute ± 12% of reading Sampling Rate: 100Hz Respiration Rate: 2~150 bpm Respiration Rate Accuracy: ±1 breath Response Time: <3 seconds - includes transport time and rise time Inspired CO2 Measurement Range: 3~50 mmhg NETWORKING Wired Networking: Industry standard: IEEE 802.3 wired network Connected bedside number: Up to 16 bedside monitors RJ45 interface or RS232 serial port Wireless Networking: Up to 100m indoors Frequency Range: 2.412~2.484 GHz Industry standard 802.11b/g wireless Supports TCP/IP and UDP/IP Protocols POWER Source: External AC power and internal battery AC Power: 100~240VAC, 50/60Hz, 150VA Battery: Rechargeable Lead-Acid Type: FB 1223 12v-2.3Ah Operating time under the normal condition: 1 hour Operating time after the first alarm of low battery: 10 minutes Manufacturer: Pilot Battery Co.,Ltd. Charge Time: 4 hours Operating Time: 1 hour ENVIRONMENTAL SPECIFICATIONS Temperature: Operating: 5~40 C Storage: -10~45 C Humidity Range: Operating: 80 % Storage: 80 % RECORDER (OPTION) Record Width: 48 (mm) Paper Speed: 25 (mm/s) Print Data: 3 waveforms with patient info and digital values FUSE T 3.0A 12151 62nd St N #5 Largo FL 33773 USA Phone: (1) 727-531-8434 Fax: (1) 727-531-8436 Web: www.infiniummedical.com Email: sale@infiniummedical.com ISO 13485