IB IL 24 PWR IN/F-D IB IL 24 PWR IN/F-D-PAC

Similar documents
IB IL 24 SEG/F. Function. INTERBUS Inline Segment Terminal With Fuse. Data Sheet 5656B

GE FANUC Parts. VersaPoint Power Terminal. Segment Terminal Fused, with Diagnostics 24VDC IC220PWR013. Features. Ordering Information

DC/DC converters - MINI-PS DC/ 5-15DC/

PHOENIX CONTACT - 01/2008

MINI MCR-SL-UI-UI(-SP)(-NC)

MINI-DC-UPS/24DC/2. Extract from the online catalog. Order No.:

QUINT-PS/24DC/24DC/20

QUINT-PS/24DC/48DC/ 5

Electronic Circuit Breaker ESS20-0..

QUINT-PS/48DC/24DC/5. DC/DC converter with SFB technology, primaryswitched, input: 48 V DC, output: 24 V DC, output current: 5 A.

QUINT-PS/24DC/24DC/10

Electronic Circuit Breaker ESS20

PHOENIX CONTACT

QUINT-PS/24DC/24DC/ 5/CO

onlinecomponents.com

Industrial Power Supplies

VersaPoint* I/O System

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

Operating instructions. FreeCon Contactless Power Contactless power transmission IE-CL240W-PP-BASE IE-CL240W-PP-REMOTE

PG02S Series 2W DC/DC CONVERTER, SIP-Package

Motor Starter Reverse MSR22-FBP

QUINT-PS/24DC/24DC/10/CO

Lexium integrated drives

Cable Duct AS-i 3.0 Motor Modules

EPS/ELA-Series User Manual EPS/ELA 250W

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S

Installation and User Guide CCMS312

Product Data Sheet DV5214 NU

Technical Specifications

Cable Duct AS-i 3.0 Motor Modules

BETA Switching Switches and Light Indicators

Emergency lighting units EM series

ABB i-bus KNX DG/S x DALI-Gateway Basic

ILE1F661PC1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox

Specifications 2019-V AC-DC Din Rail Mounted Power Supply IS-70 Series, 70W

Fieldbus Segment Protector F2-SP-IC* Features. Assembly. Function. Connection. Zone 2 Div. 2

ILA2D572TC1F0 integrated drive ILA with servo motor V - DeviceNet - indus connector

Lexium integrated drives

Analog input module. Brief description. Page 1/8. Data Sheet

LINE CONDITIONERS USER'S GUIDE

EV Charge Control Standard-compliant control of the Control Pilot and Proximity Plug interfaces between the electric vehicle and charging station

ILE1F661PB1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox

SH01S/D Series 1W DC/DC CONVERTER, SMD-Package

(typ.) (Range) ±18 330# 89 MPW MPW

Emergency lighting units EM powerled

Electronic Ballast EVG 2000-T

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power

ILE2K661PC1A1 brushless dc motor V- EtherNet/IP interface - L = 174 mm- 18:1

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Emergency lighting units EM powerled

INTER PLANT STANDARD STEEL INDUSTRY SPECIFICATION FOR STATIC EXCITATION CONVERTORS FOR SYNCHRONOUS MOTORS (FIRST REVISION)

DPX30-xxDxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

SM 1231 ANALOGINPUT MODULE

Magnetic and Hydraulic-Magnetic Circuit Breaker

Local Control Network - building controls in perfection

DPX30-xxWSxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; 3.3 to 28VDC Single Output 30 Watts Output Power

Uninterruptible power supplies (UPS)

DPX30-xxWDxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

Operators and Maintenance Manual. Display EEM MOT 01 FE02.02

Emergency lighting units EM powerled

INTER PLANT STANDARD - STEEL INDUSTRY THYRISTOR CONVERTORS FOR ARMATURE AND FIELD OF MAIN DRIVE MOTORS. Corresponding IS does not exist

Efficiency (typ.) (Range) Output Voltage Current. Input Current Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.

1.5KW DC-DC Converter Specification

DPX15-xxWDxx Dual Output: DC-DC Converter Module 9.5 ~ 36VDC, 18 ~ 75VDC input; ±5 to ±15 VDC Dual Output; 15 Watts Output Power

E-Series and EF-Series Systems

(typ.) (Range) Input Specifications Parameter Model Min. Typ. Max. Unit 12V Input Models Input Surge Voltage (100ms.

2W, Low Cost DIP, Dual Output DC/DC Converters

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series

MINI MCR-SL-UI-UI(-SP)

Magnetic and Hydraulic-Magnetic Circuit Breaker

J TS 7090 Thyristor power switch

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

Baseefa Rockhead Business Park Staden lane, Buxton, Derbyshire SK17 9RZ United Kingdom

INTECH Micro 2300-RTD6

Specifications 2019-V AC-DC Din Rail Mounted Power Supply IS-480 Series, 480W

Vehicle inlet - EV-T2GBIE12-1ACDC-20A125A2,0M

Logic module. Brief description. Features. Block structure. Data Sheet Page 1/5

UV- TECHNOLOGY. Technical Documentation ELC N6 / ELC N8 / ELC N10

Product Data Sheet. Damper Interface. Features

Series 905-IV16(E) CAN/CANopen Input Modules Installation and Operating Manual

PSU-S-12V/L-1A/5/FTA/PTC-TR-MC AWZ v.1.0

This Datasheet for the IC670MDL930. Relay 2A 8 Pt. 6 form A/2 form C Isolated.

Digital display Pressure range ON/OFF output Linear output Model

Product Data Sheet 4118 N/ The engineer's choice

Features. Description. Table of Contents

ABB i-bus KNX Hotel IP Link, Bundle HIL/S , 2CDG110237R0011

LINEAR LED DRIVERS. ComfortLine Selectable Current (Output Terminal) ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL)

Valve terminal VTUG-...-M/VTUG-...-V

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

ABB i-bus KNX HIL/S , Hotel IP Link, Bundle

Product Data Sheet 8412 NHU-519

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Encoder WDGA 58V CAN SAE J1939

User Manual Solar Charge Controller 3KW

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

1x 20A H Bridge output for controlling direction of DC motors through polarity change (MOI)

SAVE THESE INSTRUCTIONS

Conductive Polymer Aluminum Capacitors SMD (Chip), Low Impedance

Isolating transformer DS0107. Three-phase isolating transformers for the supply of three-phase loads in medical locations

Transcription:

IB IL 24 PWR IN/F-D IB IL 24 PWR IN/F-D-PAC Inline Power Terminal With Fuse and Diagnostics Data Sheet 5569C 02/2003 # # $ ' ) The IB IL 24 PWR IN/F-D and IB IL 24 PWR IN/F-D-PAC only differ in the scope of supply (see "Ordering Data" on page 11). Their function and technical data are identical. For greater clarity, the Order Designation IB IL 24 PWR IN/F-D is used throughout this document. This data sheet is only valid in association with the "Configuring and Installing the INTERBUS Inline Product Range" User Manual IB IL SYS PRO UM E. Function The terminal is designed for use within an Inline station. The terminal supplies 24 V power to the main circuit (U M ). In addition, this terminal can be used to supply 24 V power for a segment circuit (U S ). The terminal has protection against polarity reversal and surge voltage. The internal fuse protects the main circuit. This terminal has an LED for bus diagnostics and occupies two input data bits, which are used to indicate the presence of the supply voltage and the status of the fuse. Features Supply of the 24 V main voltage U M Main circuit protected by an internal fuse Supply/provision of the 24 V segment voltage U S LED diagnostic indicators 5569C 1

Local LED Diagnostic Indicators, - Des. Color Meaning 2 9 4 1., D Green Bus diagnostics ON INTERBUS is active Flashing 0.5 Hz Communications power is present, INTERBUS is not active 2 Hz Communications power is present, supply voltage U M is not present 4 Hz Communications power is present, local bus error!!!! OFF Communications power is not present, INTERBUS is not active Figure 1 " IB IL 24 PWR IN/F-D with appropriate connector Function Identification Black " " " # # $ ' )! E Red Fuse in the main circuit U M OFF Fuse is OK ON Fuse has blown If the supply voltage U M is not present and the fuse is missing or has blown, an I/O error message is sent to the higher-level control or computer system. A blown or missing fuse is indicated by both LED diagnostic indicators. The red LED E lights up and the green LED D flashes at 2 Hz. 2 5569C

Terminal Assignment Terminal Assignment Point 1.1, 2.1 Supply points for the segment circuit U S (+24 V) Connection of a switch or a jumper in the segmentation level 1.2, 2.2 Supply points for the main circuit U M (+24 V) Connection of a switch or a jumper in the segmentation level These terminal points are connected with each other and with the potential jumper of the main supply U M via the fuse. The potential jumpers of the protected main circuit U M and the segment circuit U S have a total current carrying capacity of 6.3 A. 1.3, 2.3 Ground contact (GND) for main and segment circuit The reference potential is directly routed to the potential jumper and is, at the same time, ground reference for the main and segment voltage. 1.4, 2.4 FE connection The contacts are directly connected with the potential jumper and the FE spring on the bottom of the housing. The terminal is grounded when it is snapped onto a grounded DIN rail. Terminal points 1.2 and 1.3 are connected with a capacitor to FE. Observe the current carrying capacity The maximum total current flowing through the voltage jumpers should not exceed 6.3 A. 5569C 3

Internal Circuit Diagram Key: 1 6-4 * 7 5 7 2 +, - OPC INTERBUS protocol chip (bus logic including voltage conditioning) LED marked "D" or "E" (see page 2) Optocoupler Fuse Capacitive connection to functional earth ground (FE) Electrically isolated area " 8 7 5 " 8 7 Other symbols are explained in the IB IL SYS PRO UM E User Manual. # # $ ' * " Figure 2 Internal wiring of the terminal points 4 5569C

Connection Example The 24 V supply of the main circuit is protected by an internal fuse., - 2 9 4 1., The switch can be used to create a switched segment circuit. If this is not needed for your application, you can provide the segment voltage in one of the following ways: 1 Jumper connections 1.1 and 1.2 or 2.1 and 2.2. 2 Supply the segment voltage separately. 3 Use an additional segment terminal. 7!! " " # # $ ' * # Figure 3 Typical connection of the supply voltage U M and of an external switch to supply the segment voltage U S To ensure maximum current carrying capacity, use a power connector to connect the cables (see page 11). In these connectors, the adjacent terminal points 1.2 and 2.2, and 1.3 and 2.3 are jumpered internally. Most I/O terminals are supplied from the segment circuit. 5569C 5

Programming Data ID code BE hex (190 dec ) Length code C2 hex Process data channel 2 bits Input address area 2 bits Output address area 0 bits Parameter channel 0 bits (PCP) Register length (bus) 2 bits INTERBUS Process Data Assignment of IN Process Data The IN process data only maps the status of the fuse and the main voltage. (Byte.bit) view 0.1 0.0 Assignment Main voltage U M is present, 1 1 fuse is OK Main voltage U M is present, 1 0 fuse has blown or is missing Main voltage U M is not present, fuse has blown or is missing 0 0 For the assignment of the illustrated (byte.bit) view to your control or computer system, please refer to the DB GB IBS SYS ADDRESS data sheet, Order No. 90 00 99 0. 6 5569C

Technical Data General Data Order designation (order number) IB IL 24 PWR IN/F-D (28 36 66 7) IB IL 24 PWR IN/F-D-PAC (28 61 89 4) Housing dimensions (width x height x depth) 12.2 mm x 120 mm x 71.5 mm (0.480 x 4.724 x 2.815 in.) Weight 44 g (without connectors) Operating mode Process data mode with 2 bits Transmission speed 500 kbps Permissible temperature (operation) -25 C to +55 C (-13 F to +131 F) Permissible temperature (storage/transport) -25 C to +85 C (-13 F to +185 F) Permissible humidity (operation) 75% on average, 85% occasionally In the range from -25 C to+55 C (-13 F to +131 F) appropriate measures against increased humidity (> 85%) must be taken. Permissible humidity (storage/transport) 75% on average, 85% occasionally For a short period, slight condensation may appear on the outside of the housing if, for example, the terminal is brought into a closed room from a vehicle. Permissible air pressure (operation) 80 kpa to 106 kpa (up to 2000 m [6562 ft.] above sea level) Permissible air pressure (storage/transport) 70 kpa to 106 kpa (up to 3000 m [9843 ft.] above sea level) Degree of protection IP 20 according to IEC 60529 Class of protection Class 3 according to VDE 0106, IEC 60536 Interface INTERBUS interface Power Consumption Communications power U L Current consumption at U L Power consumption at U L Main voltage U M Nominal current consumption at U M Through data routing 7.5 V DC 25 ma (maximum) 0.19 W, maximum 24 V DC (nominal value) 4.0 A (nominal value) 5569C 7

Supply of the Module Electronics Through the Bus Terminal (U L ) Connection method Through potential routing 24 V I/O Supply (Main Circuit U M ) Connection +24 V Ground (GND) Terminal points 1.2 and 2.2 Terminal points 1.3 and 2.3 Rated value 24 V DC Tolerance -15%/+20% AC component 5% Permissible range 19.2 V to 30 V Permissible current 6.3 A, maximum Demands on the voltage supply The power terminal must be supplied from a new power supply unit to provide electrical isolation. Protect the 24 V area with an external fuse. The power supply unit must be able to supply 4 times (400%) the nominal current of the external fuse. Permissible Total Current in the Potential Jumpers of the Main and Segment Circuit/Nominal Current of the Terminal Permissible total current in the potential jumpers 6.3 A Nominal current of the terminal 4.0 A Tolerance +10% Use both of the adjacent contacts to provide the main voltage and to provide/tap the segment voltage. The terminal is supplied with a 6.3 A slow-blow fuse. 8 5569C

Power Dissipation Formula to Calculate the Power Dissipation of the Electronics P EL = 0.180 W + I 2 M x R F Where P EL Total power dissipation in the terminal I M Load current in the main circuit R F Resistance of the fuse The resistance of fuse R F for a 6.3 AT fuse is approximately 12 mω. The power dissipation of the electronics for a theoretical maximum current of 6.3 A (nominal current = 4.0 A) is calculated as follows: P EL = 0.18 W + 39.69 A 2 x 0.012 Ω = 0.66 W Power Dissipation of the Housing (P HOU ) P HOU = 0.7 W in the entire ambient temperature range Typical Power Dissipation of the Electronics Depending on the Load Current in the Main Circuit P [W] Power dissipation in W I L [A] Load current in the main circuit in A 2-9 ' & % $ # "! # " $ & 1 ) # # $ ' + $ This test was carried out with a 6.3 A T fuse. Derating of the Load Current in the Segment Circuit No derating 5569C 9

Safety Devices Overload/short circuit in the main circuit Fuse 5 x 20 with 6.3 A, slow-blow Fuses with other values can also be used. The maximum fuse value should not exceed 6.3 A. Note for the selection of fuses: Only use slow-blow fuses for currents greater than 2 A. Surge voltage Polarity reversal Yes; suppressor diode for voltage limitation between terminal points 1.1 and 1.3, and terminal points 1.2 and 1.3 Yes; diode connected in parallel as protection against polarity reversal The power supply unit must be able to supply 4 times (400%) the nominal current of the internal fuse. Electrical Isolation To provide electrical isolation between the logic level and the I/O area, it is necessary to supply these areas via the bus terminal or via the bus terminal and a power terminal from separate power supply units. Interconnection of the 24 V power supplies is not permitted. Please pay attention to GND/PE connections on the power supply units (see also user manual). Common Potentials The 24 V main voltage, 24 V segment voltage, and GND have the same potential. FE is a separate potential area. Separate Potentials in the System Consisting of Bus Terminal/Power Terminal and I/O Terminal - Test Distance - Test Voltage 5 V supply incoming remote bus/7.5 V supply (bus logic) 500 V AC, 50 Hz, 1 min. 5 V supply outgoing remote bus/7.5 V supply (bus logic) 500 V AC, 50 Hz, 1 min. 7.5 V supply (bus logic)/24 V supply (I/O) 500 V AC, 50 Hz, 1 min. 24 V supply (I/O)/functional earth ground 500 V AC, 50 Hz, 1 min. 10 5569C

Error Messages to the Higher-Level Control or Computer System I/O error message if fuse blown or missing I/O error message if supply voltage U M is not present Ordering Data Description Order Designation Order No. Power terminal with fuse and diagnostics; IB IL 24 PWR IN/F-D-PAC 28 61 89 4 including connectors and labeling field Power terminal with fuse and diagnostics IB IL 24 PWR IN/F-D 28 36 66 7 One of the listed connectors is needed for the complete fitting of the IB IL 24 PWR IN/F-D terminal. Connector for power supply (black, w/o color print) pack of 10 Connector for power supply (black, with color print) pack of 10 IB IL SCN-PWR IN 27 27 46 2 IB IL SCN-PWR IN-CP 27 27 63 7 Fuse SI 5 x20 6,300 A T 50 30 51 2 "Configuring and Installing the INTERBUS Inline IB IL SYS PRO UM E 27 43 04 8 Product Range" User Manual Documentation is available at www.phoenixcontact.com. It can be downloaded free of charge. 5569C 11

Phoenix Contact GmbH & Co. KG Flachsmarktstr. 8 32825 Blomberg Germany +49-52 35-30 0 +49-52 35-34 12 00 www.phoenixcontact.com Worldwide Locations: www.phoenixcontact.com/salesnetwork Phoenix Contact 02/2003 Technical modifications reserved TN R90 02 01 9 12 5569C