SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices Metering pipe with orifice plate and annular chambers 4/369

Similar documents
SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices. Orifice plate with annular chambers. 4/358 Siemens FI

Flow Measurement SITRANS F O delta p - Primary differential pressure devices

Orifice flowmeter F O N4

94D / 94F / 94M / 96M

SITRANS P measuring instruments for pressure

VACUUM PRESSURE PUMPS INSTALLATION CAUTIONS AND INFORMATION READ AND FOLLOW CAREFULLY!

ORIFICE PLATE flow meters

FAR51. Insertion adapter with venting element Universal insertion adapter for existing flange nozzles, suitable for high temperature applications

Series 240 Type 3351 Pneumatic On/off Valve

Temperature Measurement Resistance thermometers

CFR Series. Power Inductors OUTLINE FEATURES APPLICATIONS SPECIFICATIONS MITSUMI

Series 240 Pneumatic On-off Valve Type 3351

Heavy Duty Actuators CONTROLS. Pneumatic Actuators for Quarter-Turn Valves and Dampers Torques to 1,600,000 in. lbs. Double Acting and Spring Return

THD. Series. Heavy Duty Actuators. Pneumatic Actuators for Quarter-Turn Valves and Dampers CONTROLS. Torques to 1,600,000 In-lbs

SSR SSR SSR SSR

Pressure Measurement Fittings

Direct solenoid and solenoid pilot operated valves

JUMO flowtrans DP R. Meter run R01 and orifice plate R02. Applications. Brief description. Special features. Customer benefits.

Orifice plate, model FLC-OP Orifice flange, model FLC-FL Annular chamber, model FLC-AC

10.1 Introduction Connections Overview

7. Are you upgrading a complete engine from a TCM/ Bendix to a Slick system? If yes, purchase a complete Slick Ignition Upgrade Kit.

Maintenance-free shut-off globe valves PN 25/40 DN Standard variants. Application. Operating data. Remarks. Materials

Triple Eccentric Control and Shut-off Butterfly Valve Series 14t

STAAL 100 Swing check valves PN DN Applications Standard Variants Operating Data Materials Additional Information Purchase Order Data

10.3 Flanged Connections acc. to EN 1092

Maintenance-free shut-off globe valves PN 25/40 DN Standard variants. Application. Operating data. Materials

Direct solenoid and solenoid pilot operated valves

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Data Sheet T EN

PF6 Stainless Steel Piston Actuated On/ Off Valves

Materials : Carbon steel or stainless steel

Field Variable Area Flowmeters BFP Global Purgemaster

Direct solenoid and solenoid pilot operated valves

3RG4 BERO Inductive Proximity Switches

Level Limit Switch liquiphant FTL 360 / FTL 361

Flow Measurement SITRANS F C. Flow sensor MASS 2100 DI 3 to DI 40. 4/180 Siemens FI

Thermowell for temperature sensors omnigrad M TW 13

SERVICE INSTRUCTION. 652 Oliver Street Williamsport, PA U.S.A. Tel Fax

Direct solenoid and solenoid pilot operated valves

ROTARY SHAFT / OIL SEALS GASKETS LINER RINGS REPAIR KITS BONDED SEALS O RINGS. Automotive Seals VW BARNWELL THE SEAL OF APPROVAL

Heat Transfer Fluid / Hot Water Pump HPK-L. Type Series Booklet

T EN Type 3347/3379 Pneumatic Control Valve Type 3347 Hygienic Angle Valve

TELESCOPIC CYLINDERS ø mm Series RT

DATE: May 19, 2000 Service Instruction No. 1443E (Supersedes Service Instruction No. 1443D) Engineering Aspects are FAA Approved

Series 240 Type and Type Pneumatic Control Valves Type 3248 Cryogenic Valve

SERVICE INSTRUCTION. All Certified Lycoming direct drive engines. TIME OF COMPLIANCE: At owner s discretion.

2. COMPACT CYLINDERS series STRONG (RS, RQ)

Thermowell For sanitary applications Model TW61, for orbital welding

2/2-way Angle Seat Valve, manually operated, for media up to +180 C

SELECT 3-BURNER PROPANE BARBECUE Assembly Manual

Stars or starlets? Competitor overview switching devices. Only for internal use. sirius IN COMPARISON

Process connection. Further designs. Order code. to EN

NORI 320 Globe valves PN DN Application Standard variants Operating data Materials Remarks Design

Collision Avoidance System CAS-M light. Manual

Series 46 Self-operated Regulators Differential Pressure and Flow Limiters Type 46-5 Type 46-6

LYCOMING CYLINDER PRICING

FLANGES PRODUCT: STANDARD FLANGE CLASSIFICATION: PRESSURE CLASS CLASIFICATION:

Self-operated Pressure Regulators Type Universal Pressure Reducing Valve

SITRANS T measuring instruments for temperature

Type 459. Type 459. Available designs. Cap H2. with bushing 19. Lock nut. Bonnet. Outlet flange 2.4 Outlet adaptor 2.1. spacer.

Spring Loaded Safety Valve. SiC 11/13/14

SITRANS P measuring instruments for pressure

Strainer PN 25/40 DN

PF6 Stainless Steel Piston Actuated On/Off Valves

SVL488 Stainless Steel Safety Valve for Clean Service Applications

STEAM EXTRACTION / COLD REHEAD ACTUATED CHECK VALVES

CRN. Series 740 Safety Valves. Aquatrol Safety Relief Valves


The Product Range. Technical Data

2/2-way Angle Seat Valve, manually operated, for media up to +180 C

Microbore Hose, Assemblies & accessories

Push Button Units and Indicator Lights

Exploded view 3 piece ball valves Series R

Eclipse Vortometric Burners Series HI

2- and 3-port valves with flanged connections, PN 16

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC500. 5/282 Siemens FI Overview.

SITRANS F X SITRANS FX300 3/355

Globe Valve Type Fig. 1 Type 3241 Globe Valve. Mounting and Operating Instructions EB EN

Lined Butterfly Valve Pfeiffer Type BR 10a

Thermowell For sanitary applications Model TW22

Series 14b - Type HD

AN RPM to TACH Counts Conversion. 1 Preface. 2 Audience. 3 Overview. 4 References

Orifice plates and nozzles. Flow measurement using differential pressure

MOONEY INTERNATIONAL CORPORATION The Symbol of Performancet MOONEY SPECIAL LETTER Date:

APPENDIX A Instruction Set. Op Code. T states Flags Main Effects. Instructions

CRN. Series 740 Safety Valves. 4 Aquatrol Safety Relief Valves

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

SCA Series Steel Inverted Bucket Steam Traps

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve

EXTRACTION CHECK VALVES TYPE C09.6

Direct solenoid and solenoid pilot operated valves

Type 441 XXL 442 XXL. Facts. Flanged Safety Relief Valves spring loaded. The-Safety-Valve.com. Metric Units LWN E

2- and 3-port valves with flanged connections, PN 16

FLOAT CHAMBERS BROCHURE

Contents CONTENTS. Trimod Besta level switches in Besta float chambers. The perfect combination


Type 459. Type. 459 Safety Relief Valves spring loaded

Series 240 Pneumatic Control Valve Type and Type Globe Valve Type 3241

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

Product Data Sheet , Rev KA April 2010 Rosemount 1495 and Contents

Transcription:

and annular chambers Application Suitable for non-corrosive and corrosive gases, vapors and liquids; permissible operating temperature -10 to +00 C. Design Orifice plate with annular chambers consisting of two support rings with replaceable orifice disk form A or B (see types of primary differential pressure devices in "Technical description", "Function"); flanged between inlet and outlet pipe sections with lengths according to DIN 19205. Nominal diameters EN: DN 10 to DN 50 ASME: ½ inch to 2 inch Nominal pressure EN: PN 10 to PN 100 ASME: class 150 to 600 Sealing face of the end flanges Plane, sealing face turned, N10/N12 to DIN ISO 1302, for soft gasket (PN 10 to PN 0) Plane, sealing face turned, N8 to DIN ISO 1302, for grooved gasket to DIN 2697 (PN 63 to PN 100) Plane, RF (raised faced) for versions to ASME Tapping sockets straight or bent With connection thread G½ DIN ISO 228/1, for connection dimensions to DIN 19207 form V, see page /351 With threaded connection ½-1 NPT male, for version to ASME With ferrule for pipe Ø 12 mm, S series With welding connection Ø 21.3 mm For length of tapping sockets for all metering pipe L = 120 mm and position of tapping socket, see "Technical Description" and "Function". Technical specifications Permissible operating temperature 10... + 00 C Pipes made of P235G1TH, Mat. No. 1.0305, ST37., Mat. No. 1.0255 or P235GH, Mat. No. 1.035 Tapping sockets made of P235G1TH, Mat. No. 1.0305 Flanges made of P250GH, Mat. No. 1.060 Support rings made of P250GH, Mat. No. 1.060 Orifice disk made of X 6 CrNiMoTi 17 12-2, Mat. No. 1.571 /369

and annular chambers Dimensional drawings Nominal diameter acc. to EN DN PN a b k Pipe 1) D a x s Weight kg 10 10 and 16 15 10 and 16 20 10 and 16 25 10 and 16 32 10 and 16 0 10 and 16 50 10 and 16 63 100 00 218 320 320 295 550 368 325 325 300 16 x 3.5 5 6.5 20 x 2.5 5 5.5 700 88 25 x 2.5 6.5 7 900 638 310 30 x 2.5 8 9 1 1100 788 320 38 x 3 11.5 12.5 1300 988 330 330 1500 1188 30 30 35 35 8.3 x 3.6 or 50 x 5 Metering pipes with orifice plates and annular chambers for installation between EN flanges to EN 1092.1, dimensions in mm and weights 1) The stated pipe dimensions may vary, depending on availability. The pipe dimensions used can be found in the calculation for primary differential pressure devices and/or in the order confirmation. Nom. diameter PN a b k Pipe 1) D a x s Weight kg ½ inch Class 150 ¾ inch Class 150 1 inch Class 150 11/ inch Class 150 11/2 inch Class 150 2 inch Class 150 550 368 297 700 88 297 900 638 1100 788 316 1300 988 326 1500 1188 35 371 351 Metering pipes with orifice plates and annular chambers for installation between ASME flanges to ASME B 16.5, dimensions in mm and weights 1) The stated pipe dimensions may vary, depending on availability. The pipe dimensions used can be found in the calculation for primary differential pressure devices and/or in the order confirmation. 13 15 25 60 x 5 20 22 3 3 20 x 2.5 5 5.5 25 x 2.5 6.5 7 8 30 x 2.5 8 9 1 38 x 3 11.5 12.5 1 8.3 x 3.6 or 50 x 5 13 15 25 60 x 5 20 22 3 /370

and annular chambers Selection and ordering data Metering pipe for mounting Orifice plate with annular chambers mounted permissible operating temperature -10 to +00 C, Orifice disk made of Mat. No. 1.571, support rings and flanges made of Mat. No. 1060, pipes and tapping sockets made of Mat. No. 10305, 1.0255 or 1.035 Sealing faces to the mating flanges: plane, with recess or with groove. Order No. 7 M E 1 3 1 0 77777 7777 Z Nominal diameter acc. to EN DN 10 PN 10 and PN 16 1AC 3 2 PN 25 and PN 0 1AE 3 2 PN 63 1AF 3 2 PN 100 1AG3 2 DN 15 PN 10 and PN 16 1BC 3 2 PN 25 and PN 0 1BE 3 2 PN 63 1BF 3 2 PN 100 1BG3 2 DN 20 PN 10 and PN 16 1CC 3 2 PN 25 and PN 0 1CE 3 2 DN 25 PN 10 and PN 16 1DC 3 2 PN 25 and PN 0 1DE 3 2 PN 63 1DF 3 2 PN 100 1DG3 2 DN 32 PN 10 and PN 16 1EC3 2 PN 25 and PN 0 1EE3 2 DN 0 PN 10 and PN 16 1FC3 2 PN 25 and PN 0 1FE3 2 PN 63 1FF3 2 PN 100 1FG3 2 DN 50 PN 10 and PN 16 1GC 3 2 PN 25 and PN 0 1GE 3 2 PN 63 1GF 3 2 PN 100 1GG3 2 ½ inch Class 150 5BA 3 2 5BB 3 2 5BC 3 2 ¾ inch Class 150 5CA 3 2 5CB 3 2 5CC 3 2 1 inch Class 150 5DA 3 2 5DB 3 2 5DC 3 2 1¼ inch Class 150 5EA3 2 5EB3 2 5EC3 2 Selection and ordering data Order No. Metering pipe for mounting 7 M E 1 3 1 0 77777 7777 Z 1½ inch Class 150 5FA3 2 5FB3 2 5FC3 2 2 inch Class 150 5GA 3 2 5GB 3 2 5GC 3 2 Tapping sockets With threaded connection G½; for liquids and gases PN, - Opposite one another, straight 1 A 1 B - Arranged on one side, 1 C for horizontal pipelines With threaded connection ½-1 NPT male; for liquids and gases PN, - Opposite one another, straight 1 Q 1 R - Arranged on one side, 1 S for horizontal pipelines With ferrule for pipe Ø 12 mm, S series, max. 200 C permissible - Opposite one another, straight 1 J 1 K - Arranged on one side, 1 L for horizontal pipelines With welding connection 21.3 mm; for liquids and gases PN 100 to PN 00 - Opposite one another, straight 1 D 1 E - Arranged on one side, 1 F for horizontal pipelines Shape of orifice disk aperture (see figure "Shapes of orifice disk aperture") Orifice plate form A A Quarter-circle nozzle form B B Manufactured according to pressure equipment directive (see "Questionnaire" (page /356)) Without² ) 0 According to Article 3, 1 Paragraph 3 According to category 1 2 According to category 2 3 /371

and annular chambers Selection and ordering data Order No. Metering pipe for mounting 7 M E 1 3 1 0 77777 7777 Z Further designs Order code 1) Add "-Z" to Order No. and specify Order code(s) and plain text. Calculation of orifice disk A11 aperture Add calculation sheet "Questionnaire for calculation of a primary differential pressure device acc. to DIN EN ISO 5167" to the order! Orifice plate without calculation Y01 Specify in plain text: Diameter of orifice disk aperture d =... mm Internal diameter of pipe D =... mm Radius of quarter-circle nozzle r =... mm Material certificate C02 Acceptance test certificate to EN 1020-3.1 Other materials On request Additional nominal diameters On request and nominal pressure stages according to EN and ASME Cold water pressure test On request 1.5 x PN, acceptance test certificate to EN 1020 Sealing face of metering pipe On request with orifice plate, with recess or groove Metering pipes for corrosive On request media Note on ordering Enclose a filled-out calculation sheet "Questionnaire for calculation of a primary differential pressure device according to DIN EN ISO 5167" with the order (necessary for device selection)! Scope of delivery: Orifice plate comprised of two support rings with tapping sockets and an orifice disk; flanged between inlet and outlet pipe section, with gaskets between orifice plate and support ring and between support rings and flanges of the inlet and outlet pipes, including screws and nuts. Graphite (99.85 %) flat gasket with foil insert (1.01, 0.1 mm). application for liquids, steam, gases, liquid gases, acids, hydrocarbons, oils and oil products. Accessories: See "SITRANS P measuring instruments for pressure". 1) Order codes additive, any sequence. 2) Option only available outside Europe (manufactured according to Article 3, Paragraph 3 of the pressure equipment directive, without CE marking). /372

with single tappings Tapping sockets straight or bent Application With connection thread G½ DIN ISO 228/1, for connection dimensions to DIN 19207 form V (see page /351) With threaded connection ½-1 NPT male, for version to ASME With ferrule for pipe Ø 12 mm, S series With welding connection Ø 21.3 mm For length of tapping sockets for all metering pipe L = 120 mm and position of tapping socket, see "Technical Description" and "Function". Connection size The connection size depends on the operating pressure, the temperature of the medium (DIN 19 207 and 19 211) and the medium, e.g. Suitable for non-corrosive and corrosive gases, vapors and liquids; permissible operating temperature -10 to +00 C For liquids and gases, - up to PN : Thread G½ or welding connection Ø 21.3 mm Design - from PN 6 and PN 00: Welding connection Ø 21.3 mm Orifice plate with single tappings, orifice disk aperture form A or B (see types of primary differential pressure devices in "Technical description"); flanged between standard inlet and outlet pipe sections with lengths according to DIN 19205. Nominal diameters EN: DN 10 to DN 50 - > PN 00: Welding connection Ø 2 mm For steam - up to PN 100: Thread G½ or welding connection Ø 21.3 mm - from PN 6: Welding connection Ø 2 mm Technical specifications ASME: ½ inch to 2 inch Permissible operating temperature 10... + 00 C Pipes and tapping sockets made of P235G1TH, Mat. No. 1.0305, Nominal pressure ST37., Mat. No. 1.0255 or EN: PN 10 to PN P235GH, Mat. No. 1.035 ASME: class 150 to 2 500 Flanges made of P250GH, Mat. No. 1.060 Sealing face of the end flanges Orifice plate made of Mat. No. 1.060, 1.7 Plane, sealing face turned, N10/N12 to DIN ISO 1302, for soft gasket (PN 10 to PN 0) Plane, sealing face turned, N8 to DIN ISO 1302, for grooved gasket to DIN 2697 (PN 63 to PN ) Plane, RF (raised faced) for versions to ASME Metering edge deposition welded Mat. No. 1.576 /373

with single tappings Dimensional drawings Siemens AG 2009 DN PN a b k Pipe 1) D a x s Weight kg 10 10 and 16 15 10 and 16 20 10 and 16 25 10 and 16 32 10 and 16 0 10 and 16 50 10 and 16 63 100 00 229 229 229 230 550 379 379 379 380 Metering pipes with orifice plates and with single tappings for installation between EN flanges to EN 1092-1, dimensions in mm and weights 1) The stated pipe dimensions may vary, depending on availability. The pipe dimensions used can be found in the calculation for primary differential pressure devices and/or in the order confirmation. Metering pipes with orifice plates and with single tappings for installation between ASME flanges to ASME B 16.5, dimensions in mm and weights 1) The stated pipe dimensions may vary, depending on availability. The pipe dimensions used can be found in the calculation for primary differential pressure devices and/or in the order confirmation. 297 297 700 99 900 69 69 69 650 316 1100 799 310 1300 999 999 999 1 000 1500 1 199 1 199 1 199 1 199 1 200 35 371 351 297 16 x 3.5 5 6.5 6.5 20 x 2.5 5 5.5 25 x 2.5 6.5 7 30 x 2.5 8 91 1 38 x 3 11.5 12.5 8.3 x 3.6 or 50 x 5 13 15 25 22.5 60 x 5 20 22 3 3 35 Nom. diameter PN a b k Pipe 1) D a x s Weight kg ½ inch Class 150 ¾ inch Class 150 1 inch Class 150 1¼ inch Class 150 1½ inch Class 150 2 inch Class 150 550 368 297 700 88 297 900 638 1100 788 316 1300 988 326 1500 1188 35 371 351 20 x 2.5 5 5.5 25 x 2.5 6.5 7 8 30 x 2.5 8 9 1 38 x 3 11.5 12.5 1 8.3 x 3.6 or 50 x 5 13 15 25 60 x 5 20 22 3 /37

with single tappings Selection and ordering data Metering pipe for mounting Orifice plate with single tappings, flanged Sealing faces to the mating flanges: plane Permissible operating temperature -10 to +00 C, Orifice plate made of Mat. No. 1.060, metering edge deposition welded of Mat. No. 1.576, flanges and pipes made of Mat. No. 1060, pipes and tapping sockets made of Mat. No. 10305/1.0255/or 1.035 Order No. 7 M E 1 3 2 0 77777 7777 Z Nominal diameter acc. to EN DN 10 PN 10 and PN 16 1AC 3 5 PN 25 and PN 0 1AE 3 5 PN 63 1AF 3 5 PN 100 1AG3 5 PN 1AH 3 5 DN 15 PN 10 and PN 16 1BC 3 5 PN 25 and PN 0 1BE 3 5 PN 63 1BF 3 5 PN 100 1BG3 5 PN 1BH 3 5 DN 20 PN 10 and PN 16 1CC 3 5 PN 25 and PN 0 1CE 3 5 DN 25 PN 10 and PN 16 1DC 3 5 PN 25 and PN 0 1DE 3 5 PN 63 1DF 3 5 PN 100 1DG3 5 PN 1DH 3 5 DN 32 PN 10 and PN 16 1EC3 5 PN 25 and PN 0 1EE3 5 DN 0 PN 10 and PN 16 1FC3 5 PN 25 and PN 0 1FE3 5 PN 63 1FF3 5 PN 100 1FG3 5 PN 1FH3 5 DN 50 PN 10 and PN 16 1GC 3 5 PN 25 and PN 0 1GE 3 5 PN 63 1GF 3 5 PN 100 1GG3 5 PN 1GH 3 5 ½ inch Class 150 5BA 3 5 5BB 3 5 5BC 3 5 ¾ inch Class 150 5CA 3 5 5CB 3 5 5CC 3 5 1 inch Class 150 5DA 3 5 5DB 3 5 5DC 3 5 Selection and ordering data Order No. Metering pipe for mounting 7 M E 1 3 2 0 77777 7777 Z 1¼ inch Class 150 5EA3 5 5EB3 5 5EC3 5 1½ inch Class 150 5FA3 5 5FB3 5 5FC3 5 2 inch Class 150 5GA 3 5 5GB 3 5 5GC 3 5 Tapping sockets With threaded connection G½; for liquids and gases PN, - Opposite one another, straight 1 A 1 B - Any arrangement of tapping 1 G sockets (specify angle in plain text) With threaded connection ½-1 NPT male; for liquids and gases PN, - Opposite one another, straight 1 Q 1 R - Any arrangement of tapping 1 T sockets (specify angle in plain text -Z Y02) With ferrule for pipe Ø 12 mm, S series, max. 200 C permissible - Opposite one another, straight 1 J 1 K - Any arrangement of tapping 1 M sockets (specify angle in plain text -Z Y02) With welding connection 21.3 mm; for liquids and gases PN 100... 00, or 2 mm; for liquids and gases over PN 00, for steam over PN 100 - Opposite one another, straight 1 D 1 E - Any arrangement of tapping 1 H sockets (specify angle in plain text) Shape of orifice disk aperture (see figure "Shapes of orifice disk aperture") Orifice plate form A A Quarter-circle nozzle form B B Manufactured according to pressure equipment directive (see "Questionnaire" (page /356)) Without² ) 0 According to Article 3, 1 Paragraph 3 According to category 1 2 According to category 2 3 /375

with single tappings Selection and ordering data Order No. Metering pipe for mounting 7 M E 1 3 2 0 77777 7777 Z Further designs Order code 1) Add "-Z" to Order No. and specify Order code(s) and plain text. Calculation of orifice disk A11 aperture Enclose a calculation sheet "Questionnaire for calculation of a primary differential pressure device acc. DIN EN ISO 5167" with the order! Orifice plate without calculation Y01 Specify in plain text: Diameter of orifice disk aperture d =... mm Internal diameter of pipe D =... mm Radius of quarter-circle nozzle r =... mm Material certificate C02 Acceptance test certificate to EN 1020-3.1 Other materials On request Angle between the tapping Y02 sockets Specify in plain text: Angle between the tapping sockets... Additional nominal diameters On request and nominal pressure stages according to EN and ASME Cold water pressure test On request 1.5 x PN, acceptance test certificate to EN 1020 Sealing face of metering pipe On request with orifice plate, with recess Metering pipes for corrosive On request media Note on ordering Enclose a filled-out calculation sheet "Questionnaire for calculation of a primary differential pressure device according to DIN EN ISO 5167" with the order (necessary for device selection)! Scope of delivery: One-piece orifice plate with tapping sockets flanged between inlet and outlet pipes, with gaskets between orifice plate and flanges of the inlet and outlet pipes, including screws and nuts. Graphite (99.85 %) flat gasket with foil insert (1.01, 0.1 mm). Application for liquids, steam, gases, liquid gases, acids, hydrocarbons, oils and oil products. Accessories: See "SITRANS P measuring instruments for pressure". 1) Order codes additive, any sequence. 2) Option only available outside Europe (manufactured according to Article 3, Paragraph 3 of the pressure equipment directive, without CE marking). /376

Overview When ordering a primary differential pressure device, the calculation can be ordered at the same time. Add the Order code "A11" to the Order No. of the primary device, and enclose a filled-out calculation sheet ("Questionnaire for calculation of a primary differential pressure device according to DIN EN ISO 5167) with the order. If the calculation sheet is not complete, an extra charge will be made for the additionally required calculations. Siemens AG 2009 Calculation of primary differential pressure devices Selection and Ordering data Order No. Calculation of orifice disk 7ME1910 0A Z aperture of an orifice plate, orifice plate without support rings, ISA 1932 nozzle or Venturi nozzle (without measuring sheet or sketch) Calculation of differential 7ME1910 0D Z pressure or flow on an existing primary device Further designs Order Code Please add "-Z" to Order No. and specify Order code(s) and plain text. Enclose a calculation sheet "Questionnaire for calculation of a primary Y01 differential pressure device according to DIN EN ISO 5167 with the order! /377