Shut-off dampers. Type AKK. For contaminated air PD AKK 1

Similar documents
Type AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK

Type AK FOR LOW-LEAKAGE SHUT-OFF. Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

For installation into ductwork

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

CAV controllers Type RN

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

Pressure relief dampers

Heat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en

Circular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

Ceiling swirl diffusers

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K

Ceiling swirl diffusers

Type TVLK OPTIMISED FOR USE IN LABORATORIES AND ON FUME CUPBOARDS

Ceiling swirl diffusers with perforated face plate

Ventilation grilles for installation into walls, sills or rectangular

Ceiling swirl diffusers

Ceiling swirl diffusers with perforated face plate

Ventilation grilles for installation into walls, sills or rectangular

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

Ventilation grilles for installation into walls, sills or rectangular

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF

Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION

VARYCONTROL VAV Dual Duct Terminal Boxes

5/9.2/EN/6. Volume Flow Limiter. Type VFL for insertion into air ducting. The art of handling air

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Homepage > Products > Control units > VARYCONTROL > VAV TERMINAL UNITS > Type TVR. Type TVR

Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Ventilation grilles for installation into walls, sills or rectangular

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Parts and characteristics

CONSTANTFLOW Volume Flow Controllers

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Slot diffusers for ceiling installation

Homepage > Prodotti > Unità di regolazione > Regolazione di flussi costanti CONSTANTFLOW > KVS- Regolatore di portata > Serie EN.

RN-S: 80, 100, 125 RN: 80, 100, 125, 160, 200, 250, 315, 400 RN-FL: 100, 125, 160, 200, 250, 315, 400

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

Volume Flow Limiters Type VFL

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

Type WG. External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS, AVAILABLE ALSO IN LARGE SIZES

Type TVZ. VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements

Type NAK. Gas-tight shut-off damper with pneumatic actuator

Control units. Simple. Precise. Efficient. Control units LVC, TZ-/TA-Silenzio and VFL

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

Type CF FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, FLEXIBLE ALUMINIUM CONSTRUCTION

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

Mechanical mixing box MBM

Floor diffusers. The art of handling air. Type FB. In aluminium and plastic

Multileaf damper with actuator

TYPE EK-EU SMOKE CONTROL DAMPER

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m

Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS

Fire damper ETPR. Specifications. Product code example Fire damper ETPR

Technical documentation

series RVV Variable flow rate controllers

Type VSD35. Nominal length up to 1500 mm: one spigot

VAV Terminal Units SDS

Fan - Powered Terminal Unit Series Flow

NR series. Circular CAV air volume control terminals with system powered mechanical regulator

Technical information

CRP. Commissioning damper, Ductwork Leakage Class 0 QUICK FACTS. Perforated damper blade for better damper characteristic

Type WG-JZ COMBINATION WITH A MULTILEAF DAMPER. PÁGINA PRINCIPAL > Productos > Rejas para intemperie - compuertas de regulación

Zero Leakage Isolation Damper

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

Air terminal devices

VOLUME CONTROL / REGULATING DAMPERS

DD Series. Duct Regulating Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S. Two blade options.

Aircell Polymer Range

NV series. Induction VAV air volume control terminals

SDV Vane Swirl Diffusers

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

Particle Filter Box FKU

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

2/1/EN/3. Slot Diffuser. Type VSD15. with 15 mm wide diffuser face

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex

Transcription:

X X testregistrierung Shut-off dampers Type Variant with circular spigot For contaminated air Plastic circular shut-off dampers for shutting off aggressive media volume flows in air conditioning systems Maintenance-free damper blade mechanism Closed blade air leakage to EN 1751, class 3 Casing air leakage to EN 1751, class B Variant for manual operation Optional equipment and accessories Electric actuator Spring return actuator Pneumatic actuator Auxiliary switch with adjustable switching points for capturing the end positions HYGIENE TESTED V DI 6022 Tested to VDI 6022 PD 1

General information Type Page General information 2 Function 3 Technical data 4 Quick sizing 5 Specification text 6 Order code 7 Variants 8 Attachments 9 Dimensions and weight 11 Installation details 14 Basic information and nomenclature 15 Application Application Plastic circular shut-off dampers Type for shutting off or restricting the airflow in ventilation ducts of air conditioning systems Suitable for contaminated air Special features Damper blade can be actuated manually, electrically or pneumatically Low-leakage shut-off Safety function provided by optional spring return actuator Nominal sizes 125, 160, 200, 250, 315, 400 Description Variants : Shut-off damper -FL: Shut-off damper with flanges on both ends Parts and characteristics Ready-to-install shut-off damper Damper blade with blade mechanism Attachments Open/Close actuators: For the opening and closing of shut-off dampers in air conditioning systems Auxiliary switch for capturing the end positions Accessories Matching flanges for both ends, including seals Construction features Circular casing Spigot suitable for ducts according to DIN 8077 Position of the damper blade indicated externally at the shaft extension All components coming into contact with the airflow are made of plastic (no interior metal parts) Materials and surfaces Casing and damper blade made of flame- resistant polypropylene (PPs) Plain bearings made of polypropylene (PP) Damper blade seals in chloroprene rubber (CR) Standards and guidelines Hygiene conforms to VDI 6022 Closed blade air leakage to EN 1751, class 3 Meets the general requirements of DIN 1946, part 4, with regard to the acceptable closed blade air leakage Casing air leakage to EN 1751, class B Maintenance Maintenance-free as construction and materials are not subject to wear PD 2

Function Schematic illustration of the (construction variant with flange) 1 2 4 3 1 Damper blade 2 Plain bearings 3 Flange 4 Actuator PD 3

Technical data Nominal sizes 125 400 mm Acceptable static differential pressure 1500 Pa Operating temperature 10 50 C PD 4

Quick sizing Quick sizing tables provide a good overview of the room sound pressure levels that can be expected. Approximate intermediate values can be interpolated. Precise intermediate values and spectral data can be calculated with our Easy Product Finder design programme. Quick sizing: Static differential pressure and sound pressure levels with open damper blade Nominal size Differential pressure p st Air-regenerated noise L PA 125 160 200 250 315 400 l/s m³/h Pa db(a) 15 54 5 <15 60 216 10 24 105 378 25 36 150 540 50 45 25 90 5 <15 100 360 10 22 175 630 20 33 250 900 45 41 40 144 5 <15 160 576 10 21 280 1008 20 31 405 1458 40 39 60 216 <5 <15 250 900 5 19 430 1548 15 29 615 2214 30 38 100 360 <5 <15 410 1476 5 21 720 2592 15 34 1030 3708 25 43 170 612 <5 <15 670 2412 5 34 1175 4230 10 50 1680 6048 15 61 PD 5

Specification text This specification text describes the general properties of the product. Texts for variants can be generated with our Easy Product Finder design programme. Circular shut-off dampers in PPs plastic for air conditioning systems, available in 6 nominal sizes. Suitable for shutting off or restricting extract air flows containing aggressive substances since all components coming into contact with the airflow are made of plastic (no interior metal parts). Suitable for duct pressures up to 1500 Pa. Ready-to-install unit consists of the casing with a damper blade. Spigot, suitable for ducts according to DIN 8077. Position of the damper blade indicated externally at the shaft extension. Closed blade air leakage to EN 1751, class 3. Casing air leakage to EN 1751, class B. Special features Damper blade can be actuated manually, electrically or pneumatically Low-leakage shut-off Safety function provided by optional spring return actuator Materials and surfaces Casing and damper blade made of flame- resistant polypropylene (PPs) Plain bearings made of polypropylene (PP) Damper blade seals in chloroprene rubber (CR) Technical data Nominal sizes: 125 400 mm Acceptable static differential pressure: 1500 Pa Sizing data [m³/h] Air-regenerated noise L PA [db(a)] PD 6

Order code FL / 160 / GK / BP0 / NO Type Shut-off damper, plastic Flange No entry: none FL Flanges on both ends Nominal size [mm] 125 160 200 250 315 400 Accessories No entry: none GK Matching flanges for both ends Order example: /160/B30 Nominal size Actuator Actuator No entry: manual operation For example B20 24 V AC/DC, modulating 2 10 V DC B30 24 V AC/DC, 3-point B32 24 V AC/DC, 3-point, with auxiliary switch TN0 Pneumatic 0.2 1 bar Damper blade position Only for spring return actuators and pneumatic actuators NO Pressure off/power off to OPEN NC Power off/pressure off to close 160 mm Supply voltage 24 V AC/DC PD 7

Variants Shut-off dampers Type shut-off damper, variant with actuator PD 8

Attachments, electric actuators Order code detail Actuator Supply voltage Auxiliary switch Open/Close actuators B30 24 V AC/DC B32 Actuator with mechanical stops 2 B40 TROX/Belimo 100 240 V AC B42 2 BP0 24 V AC/DC BP2 Spring return actuator with mechanical stops 2 BR0 TROX/Belimo 24 240 V AC, 24 125 V DC BR2 2 Modulating actuators Modulating actuator 0 10 V with mechanical stops B20 24 V AC/DC TROX/Belimo PD 9

Attachments, pneumatic actuators Order code detail Actuator Control pressure Auxiliary switch Pneumatic actuators TN0 Pneumatic actuator TROX 0.2 1.0 bar PD 10

Dimensions and weight L ØD H₃ 230 B₃ Nominal size ØD L B 3 H 3 m mm mm mm mm kg 125 125 394 195 145 1.2 160 160 394 230 180 1.5 200 200 394 270 220 1.9 250 250 594 320 270 3.1 315 315 594 385 335 5.0 400 400 594 470 420 7.2 /.../B** (electric actuators) L B₃ ~ 80 ØD /.../B** Nominal size ØD L B 3 H 3 m mm mm mm mm kg 125 125 394 195 145 3.1 160 160 394 230 180 3.4 200 200 394 270 220 3.8 250 250 594 320 270 5.0 315 315 594 385 335 6.9 400 400 594 470 420 9.1 PD 11

Dimensions and weight /.../.../TN0 (pneumatic actuator) 320 ØD 330 350 200 230 B₃ 100 L /.../TN0 Nominal size -FL ØD L B 3 H 3 m mm mm mm mm kg 125 125 394 195 145 2.9 160 160 394 230 180 3.2 200 200 394 270 220 3.6 250 250 594 320 270 4.8 315 315 594 385 335 6.7 400 400 594 470 420 8.9 ØD₂ L ØD₁ ~ 80 ØD n x Ø10 T B₃ PD 12

Dimensions and weight -FL Nominal size -FL - FL/.../ B** - FL/.../ TN0 m ØD L B 3 H 3 ØD 1 ØD 2 n T kg kg kg mm mm mm mm mm mm mm 125 1.5 3.4 3.2 125 400 195 145 165 185 8 8 160 1.9 3.8 3.6 160 400 230 180 200 230 8 8 200 2.4 4.3 4.1 200 400 270 220 240 270 8 8 250 3.7 5.6 5.4 250 600 320 270 290 320 12 8 315 6.0 7.9 7.7 315 600 385 335 350 395 12 10 400 8.5 10.4 10.2 400 600 470 420 445 475 16 10 PD 13

Installation details Installation and commissioning Any installation orientation Space required for commissioning and maintenance Sufficient space must be kept clear near any attachments to allow for commissioning and maintenance. It may be necessary to provide sufficiently sized inspection access openings. Access to attachments, attached on one side 3 2 1 Space required Attachments 1 2 3 Without actuator 250 150 200 With electric actuator 300 200 300 With pneumatic actuator 400 350 300 mm PD 14

Basic information and nomenclature Principal dimensions ØD [mm] Shut-off and flow adjustment dampers made of stainless steel: Outer diameter of the connecting spigot Shut-off dampers made of plastic: Inside diameter of the connecting spigot ØD₁ [mm] Pitch circle diameter of flanges ØD₂ [mm] Outer diameter of flanges ØD₄ [mm] Inside diameter of the screw holes of flanges L [mm] Length of unit including connecting spigot L₁ [mm] Length of casing or acoustic cladding n [ ] Number of flange screw holes T [mm] Flange thickness m [kg] Unit weight including the minimum required attachments Acoustic data L PA [db(a)] A-weighted sound pressure level of air- regenerated noise of the shut-off or flow adjustment damper, system attenuation taken into account All sound pressure levels are based on 20 μpa. Definition of noise 2 1 L PA 1 Air-regenerated noise 2 Case-radiated noise Volume flow rates Volume flow rate [m³/h] and [l/s] Differential pressure Static differential pressure Δp st [Pa] Static differential pressure p st PD 15