OE326-23I-OR VAV/Zone Controller

Similar documents
LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

GMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1.

NMQB24-MFT, NMQX24-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

NMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

Minimum 27 in-lb torque

LF Series Spring Return Direct Coupled Actuator

Minimum 27 in-lb Torque

Versatile and Powerful

CCS Zone/Bypass Damper Assembly

INSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone.

Versatile and Powerful

SD-1250 and SD-1600 Series Smoke Dampers

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

YCCS Zone/Bypass Damper Assembly

ACCUVALVE MODEL AVC6000 SUBMITTAL MATERIALS MODEL CODE. AccuValve Model AVC6000 AVC6 - - DWG. NO: REVISION: REV. DATE:

SECTION CONTROL DAMPERS

Minimum 90 in-lb Torque. Applications. NFB, NFX Series At A Glance. NFB and NFX Series Spring Return Direct Coupled Actuator

GM Series Direct Coupled Actuator

ZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

YCCS Zone/Bypass Damper Assembly

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

MC-351, 421, 431, MC-4311

Description. functions including single duct pressure dependent or pressure independent systems.

SP Standard Profile. In Duct or Flanged to Duct Install Types OPPOSED ACTION PARALLEL ACTION. Extended Rear Flange Install Type

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

Laboratory Room Controller

LF Series At A Glance

MX4X-6XXX Series MX4X-7XXX Series. Selection Guide. Applications. DuraDrive Series Actuators and Accessories

Commercial Actuator Selection Chart Non-Spring Return

Minimum 18 in-lb Torque. Applications. TF Series At A Glance. TF Series Spring Return Direct Coupled Actuator. For damper areas up to 4.

Variable Air Volume Dampers

ATP-2040 Electric Damper Actuator/Transmitter

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

Accutrol, LLC Product Sheet AVC6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

How to Select the RE Industrial Actuator Part Number

INSTALLATION INSTRUCTION

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

SDL Single-Duct, Low-Height, VAV Terminals

Powers TM Controls EA 338 Electronic Actuator

MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS

NFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V

RETROFIT TERMINAL UNITS

Metasys Zoning Package Installation

MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

MA-5200 Series MA-5300 Series

M9216 Series Electric Spring Return Actuators

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

BACnet Lab and Pressurized Room Controllers with Off-board Air Modules

ZG106 or ZG 107 bracket

Installation/ Operation Maintenance. VariTrac Dampers

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2" Centered (Default) 3/4" Centered (Field Selectable)

AMD-33 Air Measuring Station with VCD-33 Control Damper

Zone Valves and Parts (Honeywell)

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

PIM Pressure Independence Module

Accutrol, LLC Product Sheet AVT6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

TSS Single-Duct VAV Terminals

INSTALLATION INSTRUCTION

Mount directly to 1.05 jackshafts. AF230 US (p. 02) AF230-S US (p. 20) AF24-S US (p. 18)

MS Application. Features. Proportional Valve Actuator General Instructions

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

SECTION AIR TERMINAL UNITS

Powermite 599 MT Series SQS Electronic Valve Actuator, 24 Vac, Floating Control (3-position)

MANUAL INSTALLATION. Venturi FX. VFX Series. v100 Issue Date: 11/22/ Price Industries Limited. All rights reserved.

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD

FSAF24(-S) US, FSAF120(-S) US

Introduction to Johnson Controls Dampers

Minimum 18 in-lb Torque

University of Delaware

PIM Pressure Independent Module

Product Cross Reference

Complete HVAC Capability

M9208-xxx-x Series Electric Spring Return Actuators

Technical Documentation Pressure Independent Characterized Control Valves (PICCV) Patented Effective December 2007

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.

OPTIONS BLANK = No Options B = BACnet MS/TP D = Internal Transmitter Display (Ref Note 4)

Product Data. 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems. 40 to 3700 cfm

LMX24-3 (-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

2520- EC Motor Speed Controller

OE & OE Digital Room Sensor

Transcription:

+ 4 8 - Description The OE36-3I-OR is a that is designed for pressure independent VAV Box and Zone Damper applications. It is supplied with an integral Airflow Sensor and is mounted in a plastic enclosure. The is designed for use with an OE8-0 Damper Actuator with cable package. The controller and actuator can be purchased separately or as a combined package (referenced below). The connects to the actuator via the modular cable included with the actuator. One stage of Aux Heat is provided on the controller. The can use a Standard Room Temperature Sensor wired to the 3 pole terminal block provided or an E-BUS Digital Room Sensor connected via the integral E-BUS cable connector or to the 4 pole terminal block provided. The also has a pole terminal block for wiring a Discharge Temperature Sensor, if desired. An optional Reheat Expansion Module is available for applications using fan terminals and/or more than stage of Heat, SCR electric heat, or if using modulating HW heat. The Expansion Module connects to the by means of a prefabricated E-BUS cable. Package OE744-0P-VAVZ (Pressure Independent Package) includes the Zone and Actuator. Package OE744-03P- VAVZ (Pressure Independent Package) includes the Zone, Actuator, and Reheat Expansion Module. 4.0.05 OE36-3I-OR Mounting The is very easy to mount on your terminal unit or to a round or rectangular damper mounting plate. Three holes are provided in the plastic controller housing for mounting to a control panel base. Detailed mounting and installation instructions are provided with each package. Form: ORION-OE36-3I-OR-0A.doc Page of OCC. SWITCH BIN C9.00uF E-BUS TB4 DUCT SENSOR C34 R60 R59 COMM POWER INPUT P TMP R+ SH T- 0uF 48 - C5 R4 R3 4 VAC 4 VAC POWER ONLY WARNING! POLARITY MUST BE OBSERVED OR THE CONTROLLER WILL BE DAMAGED WattMaster Label #L037 Rev.: 0A B D7 R TB DIGITAL SPACE C US.05 D9 E-BUS CONNECTORS COMM POWER APP HB WDOG OS HB STAT STAT J ON ADDRESS +V R5 R30 R9 R8 OCCUPIED SWITCH BIN DUCT TEMP SENSOR R5 R5 OFF R5 5.64 TB6 TMP ADDRESS ON 6 3 R37 SPACE SENSOR 5.05 DIGITAL SPACE SENSOR LOOP BAUD SW ADJ TMP R37 C5 R0 R C4 R6 + www.orioncontrols.com V AUX HEAT 6 3 VDE VDC VAC ~ D3 + VDC TB3 HI LO HI ANALOG SPACE SENSOR OE36-3I-OR P.I. VAV /ZONE CONTROLLER Technical Data OE36-3I-OR Pressure Independent General Specifications: Inputs: Supply Power 4 VAC () 3 Pole Terminal Block Connector For Comm In & Out Power Consumption Operating Temperature Operating Humidity www.wattmaster.com ADDRESS SWITCH BAUD 475 AUXILIARY HEAT 475 0uF RELAY CONTACT RATING IS AMP MAX @ 4 VAC V4 TB5 D R4 D R CCW C5 CW 0 ACTUATOR ADJ TMP COM HEAT P3 LO 3.3V 5.0V AIRFLOW TP YS0588 REV 6 VA Maximum () Pole Terminal Block Connector For Power In 0 F to 49 F 0-90% RH Non-Condensing ACTUATOR CONNECTOR V3 SERIAL # 0.9.6 () Pole Terminal Block For Discharge Temperature Sensor Connection () Pole Terminal Block for Occupancy or Window Switch Terminals Communications RS-485 57,600 Baud Hi & Lo Pressure Tube Fittings For Integral Air Flow Sensor (P.I. s Only) Inputs: Outputs: () 3 Pole Terminal Block for Analog Room Temperature Sensor Applications () 4 Pole Terminal Block for E-BUS Digital Room Sensor Applications () E-BUS Connectors For Connection of Expansion Module and/or E-BUS Digital Room Temperature Sensor () RJ-45 Modular Connector for Connection of Actuator.49 5.8 () Pole Terminal For Connection Of Auxiliary Heat Contactor WattMaster reserves the right to change specifications without notice. All Dimensions are in inches. Three Year Warranty

+ 4 8 - B R C US Description The OE36-3D-OR is a designed for pressure dependent VAV Box and Zone Damper applications and is mounted in a plastic enclosure. The is designed for use with an OE8-0 Damper Actuator with cable package. The controller and actuator can be purchased separately or as a combined package (referenced below). The connects to the actuator via the modular cable that is included with the actuator. One stage of Aux Heat is provided on the controller. The can use a Standard Room Temperature Sensor wired to the 3 pole terminal block provided or an E-BUS Digital Room Sensor connected via the integral E-BUS cable connector or to the 4 pole terminal block provided. The also has a pole terminal block for wiring a Discharge Temperature Sensor, if desired. An optional Reheat Expansion Module is available for applications using fan terminals and/or more than stage of Heat, SCR electric heat, or if using modulating HW heat. The Expansion Module connects to the by means of a prefabricated E-BUS cable. Package OE74-0P-VAVZ (Pressure Dependent Package) includes the Zone and Actuator. Package OE74-03P-VAVZ (Pressure Dependent Package) includes the Zone, Actuator, and Reheat Expansion Module. 4.0.05.05 OCC. SWITCH OE36-3D-OR P.D. 5.8.0 Mounting The is very easy to mount on your terminal unit or to a round or rectangular damper mounting plate. Three holes are provided in the plastic controller housing for mounting to a control panel base. Detailed mounting and installation instructions are provided with each package. BIN C9.00uF 48 E-BUS TB4 DUCT SENSOR - C34 R60 R59 COMM POWER INPUT WattMaster Label #L038 Rev.: 0A P TMP D7 0uF R+ SH T- C5 R4 R3 4 VAC 4 VAC POWER ONLY WARNING! POLARITY MUST BE OBSERVED OR THE CONTROLLER WILL BE DAMAGED TB DIGITAL SPACE D9 E-BUS CONNECTORS COMM POWER APP HB WDOG OS HB STAT STAT J ON ADDRESS +V R5 R30 R9 R8 OCCUPIED SWITCH BIN DUCT TEMP SENSOR R5 R5 OFF R5 5.64 TB6 6 3 R37 SPACE SENSOR TMP ADDRESS ON 5.05 LOOP BAUD SW ADJ TMP R37 C5 R0 R C4 R6 DIGITAL SPACE SENSOR V + AUX HEAT www.orioncontrols.com VDE VDC VAC ~ D3 + VDC TB3 475 ANALOG SPACE SENSOR OE36-3D-OR P.D. VAV /ZONE CONTROLLER www.wattmaster.com ADDRESS SWITCH 6 3 BAUD 475 0uF V4 RELAY CONTACT RATING IS AMP MAX @ 4 VAC AUXILIARY HEAT TB5 D R4 D R CCW C5 CW 0 ACTUATOR ADJ TMP COM P3 HEAT ACTUATOR CONNECTOR 3.3V 5.0V AIRFLOW TP YS0588 REV V3 SERIAL # 0.9.6.49 Technical Data OE36-3D-OR P.D. General Specifications: Inputs: Supply Power 4 VAC () 3 Pole Terminal Block Connector For Comm In & Out Power Consumption 6 VA Maximum () Pole Terminal Block Connector For Power In Operating Temperature 0 F to 49 F () Pole Terminal Block For Discharge Temperature Sensor Connection Operating Humidity Communications Inputs: 0-90% RH Non-Condensing RS-485 57,600 Baud () 3 Pole Terminal Block for Analog Room Temperature Sensor Applications () 4 Pole Terminal Block for E-BUS Digital Room Temperature Sensor Applications () Pole Terminal Block for Occupancy or Window Switch Terminals Outputs: () E-BUS Connectors For Connection of Expansion Module and/or E-BUS Digital Room Temperature Sensor () RJ-45 Modular Connector for Connection of Actuator () Pole Terminal For Connection Of Auxiliary Heat Contactor WattMaster reserves the right to change specifications without notice. All Dimensions are in inches. Three Year Warranty Form: ORION-OE36-3D-OR -0A.doc Page of

5.70 OE8-0 Zone Damper Actuator Description The OE8-0 Zone Damper Actuator is a shaft mounted, floating point control actuator with an included phone jack cable. Actuators are 4VAC/4VDC with a 0K ohm feedback signal for position monitoring. Wiring connection to the actuator is by means of a modular phone cable connector located on the actuator cover. The actuator is rated for 45 in-lb of torque. All actuators are electronically protected against overload. The angle of rotation is mechanically limited to 95. When the end position of the actuator or damper is reached, the actuator automatically stops. For adjustment purposes, the gears can be manually disengaged by pushing the manual override button on the actuator cover. 0.38 OE8 Damper Actuator Applications The OE8-0 Zone Damper Actuator is used to provide control of air volume dampers in a VAV or Zoning system. Modular Jack Connection 0.75 The actuator is included in the OE74-0P-VAVZ or OE74-03P-VAVZ. P.D. Packages or the OE744-0P-VAVZ and OE744-03P-VAVZ. P.I. Packages. 8 Long Modular Cable The OE8-0 Zone Damper Actuator is also included in the following zone damper packages: OE50-XX-PT, OE50-XX-PM, OE5-XX-PT, and OE5-XX-PM, where XX = 06,08,,4,6 the size of the damper. Technical Data OE8-0 Zone Damper Actuator Power Supply 4VAC 0% 50/60HZ Angle of Rotation Max. 95, Adjustable Life Cycle Rating.5 Million Cycles with Mechanical Stops Power Consumption 3 VA Maximum Power Connection RJ- Modular Jack Operating Temp - F to F Servicing Maintenance Free Operating Humidity 5 to 95% RH Non- Quality Standard ISO 900 Condensing Shaft Size Self-Centering - Adjustable from 3 / 8 to ½ Direction of Rotation Reversible with Switch Overload Protection Electronic Throughout 0 to 95 Rotation Agency Listings UL873 listed CSA 483 0 Certified and/or culus acc. to UL 60730-A/--4, CAN/CSA E60730-:0, CE acc. to 004/08/EEC and 006/95/EC Feedback Signal 0K ohm W Potentiometer Torque Minimum 45 in-lb Running Time 80-0 Seconds. Weight. lb. Three Year Warranty WattMaster reserves the right to change specifications without notice Form: ORION-OE8-0ZoneDmprAct-Sub-0B.doc Page of

4 3 4 3 OE35-03 Expansion Module Description The OE35-03 Expansion Module is used in conjunction with the OE36-3I-OR & OE36-3D-OR to allow for control of fans included in series and parallel flow fan terminal units and/or additional staged or modulating heat. It can also control up to 3 stages of electric heat, SCR electric heat, on/off HW heat, or modulating hot water heat. The OE35-03 Expansion Module provides 4 relay outputs for pilot duty switching control, ( fan and 3 heat) relay outputs and analog output for control of a 0-0V modulating hot water valve or SCR controlled electric heating coil. SERIAL # P U6 TB D4 R8 C9 R7 R6 AOUT U5 R3 R R R0 C 05 YS053 REV R WATTMASTER CONTROLS, INC D MADE IN USA Q C0 R9 C C7 C6 U7 R U3 3.0" US C8 TB R R C U8 D Q U4 R D5 R3 C R8 J U R0 R9 D3 BIN R D6 D3 Q3 R3 D7 D8 COM D4 Q4 U C3 C X C3 ALRM STAT COMM PWR TB3 R5 C4 C5 R5 R6 R7 R4 4.8" 4.34".35" The OE35-03 Expansion Module connects to the controllers mentioned previously by means of an E-BUS cable that is provided with the Expansion Module. Power to this board is also supplied to the board by means of this E-BUS cable for the. De-pluggable screw terminals are provided for connection of field wiring to the relays outputs, the analog outputs, and the binary input (not used in this application). The relay outputs are N.O. contacts with one common terminal. All outputs and the relay common are electrically isolated from all other circuitry on the board. All relay outputs are supplied with transient suppression devices across each set of contacts to reduce EMI and contact arcing. The relay output circuits are rated for pilot duty control of a maximum of Amp @ 4 VAC or 4 VDC each. These outputs require a separate 4 VAC transformer provided by others. The analog output provides a 0-0 VDC modulating signal output into a K Ohm minimum load. If a Modulating Hot Water Valve is being used, it will also need a 4 VAC transformer by others for its power source. Mounting The OE35-03 Expansion Module is supplied mounted on a plastic snap track channel. The snap track channel has a single mounting hole which is used to field mount the board with the provided screw. The module should be mounted in close proximity to the to allow for connection with the supplied E-BUS cable. Technical Data OE35-03 Expansion Module Operating Temp 0 F to 49 F Operating Humidity 0-90% RH Non-Condensing Weight 4 oz. Connection to : E-BUS Modular Cable Analog Output Qty & Rating Relay Output Qty. Relay Circuit Rating Outputs: () 0-0 VDC @ K Ohm Minimum load 4 Electrically Isolated Amp @ 4 VAC Binary Input E-BUS CABLE PL053 EXPANSION BOARD 8.00" Inputs: SNAP TRACK CHANNEL Not Used for this Application Form: ORION-OE35-03-ExpMod-0A.doc Page of

OE74-03-OR Pressure Dependent Package Description The OE74-03-OR Pressure Dependent Package with Terminal Block connectors provides the latest solution for zone damper applications. The package includes the OE36-3D-OR mounted in a plastic enclosure and the OE8-0 Zone Damper Actuator with cable. Mounting The Package is very easy to mount on your terminal unit. There are four conduit holes that are sized for ½ conduit fittings that are provided for as part of the mounting plate that is on the Orion series of zone dampers - OE50-XX-PT or OE5-XX-PT. The rectangular damper kit also has four ½ conduit knock-outs in its enclosure as well. Detailed mounting and installation instructions are provided with each VAV Zone Package. Technical Data OE36-3D-OR P.D. Zone General Specifications: Inputs: Supply Power 4 VAC () 3 Pole Terminal Block Connector For Comm In & Out Power Consumption 6 VA Maximum () Pole Terminal Block Connector For Power In Operating Temperature 0 F to 49 F () Pole Terminal Block For Discharge Temperature Sensor Connection Operating Humidity 0-90% RH Non-Condensing Communications RS-485 57,600 Baud Inputs: () 3 Pole Terminal Block for Analog Room Temperature Sensor Applications () 4 Pole Terminal Block for E-BUS Digital Room Temperature Sensor Applications () Pole Terminal Block for Occupancy or Window Switch Terminals Outputs: () E-BUS Connectors For Connection of Expansion Module and/or E-BUS Digital Room Temperature Sensor () RJ-45 Modular Connector for Connection of Actuator () Pole Terminal For Connection Of Auxiliary Heat Contactor WattMaster reserves the right to change specifications without notice. All Dimensions are in inches. Three Year Warranty Form: Orion-OE74-03-OR-0A.doc Page of

OE74-03-OR Pressure Dependent Package Technical Data OE8-0 Zone Damper Actuator Power Supply 4VAC 0% 50/60HZ Angle of Rotation Max. 95, Adjustable Life Cycle Rating.5 Million Cycles with Mechanical Stops Power Consumption 3 VA Maximum Power Connection RJ- Modular Jack Operating Temp - F to F Servicing Maintenance Free Operating Humidity 5 to 95% RH Non- Quality Standard ISO 900 Condensing Shaft Size Self-Centering - Adjustable from 3 / 8 to ½ Direction of Rotation Reversible with Switch Overload Protection Electronic Throughout 0 to 95 Rotation Agency Listings UL873 listed CSA 483 0 Certified and/or culus acc. to UL 60730-A/--4, CAN/CSA E60730-:0, CE acc. to 004/08/EEC and 006/95/EC Feedback Signal 0K ohm W Potentiometer Torque Minimum 45 in-lb Running Time 80-0 Seconds. Weight. lb. WattMaster reserves the right to change specifications without notice. All Dimensions are in inches. Three Year Warranty of Form: Orion-OE74-03-OR-0A.doc

B P 0uF D7 D9 + J R30 R9 R8 R R5 R5 OFF 4 8 - R5 R5 LOOP BAUD C5 www.orioncontrols.com www.wattmaster.com 48 V C4 R6 D3 BAUD - HI 475 475 D D 0uF V4 P3 V3 5.70 OE744-03-OR Pressure Independent Package Description The OE744-03-OR Pressure Independent Package with Terminal Block connectors provides the latest solution for zone damper applications. The package includes the OE36-3I-OR mounted in a plastic enclosure, the OE8-0 Zone Damper Actuator with cable, and an Airflow Sensor. OCC. SWITCH BIN TB4 C34 R60 DUCT R59 SENSOR TMP TB DIGITAL SPACE C5 R4 R3 +V 5.64 TB6 SPACE SENSOR R37 ADJ TMP R37 R0 R TB3 LO HI LO 3.3V 5.0V AIRFLOW TP YS0588 REV.49 0.38 OE8 Damper Actuator Mounting The Package is very easy to mount on your terminal unit. There are four conduit holes that are sized for ½ conduit fittings that are provided for as part of the mounting plate that is on the Orion series of zone dampers - OE50-XX-PT or OE5-XX- PT. The rectangular damper kit also has four ½ conduit knockouts in its enclosure as well. Detailed mounting and installation instructions are provided with each Package. 4.0.05.05 C9.00uF E-BUS COMM POWER INPUT R+ SH T- 4 VAC 4 VAC POWER ONLY WARNING! POLARITY MUST BE OBSERVED OR THE CONTROLLER WILL BE DAMAGED WattMaster Label #L037 Rev.: 0A OCCUPIED SWITCH E-BUS CONNECTORS COMM POWER APP HB WDOG OS HB STAT STAT ON ADDRESS BIN DUCT TEMP SENSOR TMP DIGITAL SPACE SENSOR + ADDRESS ON 6 3 5.05 ADDRESS SWITCH SW 6 3 AUX HEAT + VDC VDE VDC VAC ~ ANALOG SPACE SENSOR OE36-3I-OR P.I. VAV /ZONE CONTROLLER C US AUXILIARY HEAT RELAY CONTACT RATING IS AMP MAX @ 4 VAC TB5 R4 R CCW C5 CW 0 ACTUATOR ADJ TMP COM HEAT ACTUATOR CONNECTOR SERIAL # 0.9.6 5.8.0 0.75 Modular Jack Connection 8 Long Modular Cable Technical Data OE36-3I-OR Pressure Independent General Specifications: Inputs: Supply Power 4 VAC () 3 Pole Terminal Block Connector For Comm In & Out Consump- Power tion Operating Temperature Operating Humidity 6 VA Maximum () Pole Terminal Block Connector For Power In 0 F to 49 F 0-90% RH Non-Condensing () Pole Terminal Block For Discharge Temperature Sensor Connection () Pole Terminal Block for Occupancy or Window Switch Terminals Communications RS-485 57,600 Baud Hi & Lo Pressure Tube Fittings For Integral Air Flow Sensor (P.I. s Only) Inputs: Outputs: () 3 Pole Terminal Block for Analog Room Temperature Sensor Applications () 4 Pole Terminal Block for E-BUS Digital Room Sensor Applications () E-BUS Connectors For Connection of Expansion Module and/or E-BUS Digital Room Temperature Sensor () RJ-45 Modular Connector for Connection of Actuator () Pole Terminal For Connection Of Auxiliary Heat Contactor WattMaster reserves the right to change specifications without notice. All Dimensions are in inches. Three Year Warranty Form: Orion-OE744-03-OR-A.doc Page of

OE744-03-OR Pressure Independent Package Technical Data OE8-0 Zone Damper Actuator Power Supply 4VAC 0% 50/60HZ Angle of Rotation Max. 95, Adjustable Life Cycle Rating.5 Million Cycles with Mechanical Stops Power Consumption 3 VA Maximum Power Connection RJ- Modular Jack Operating Temp - F to F Servicing Maintenance Free Operating Humidity 5 to 95% RH Non- Quality Standard ISO 900 Condensing Shaft Size Self-Centering - Adjustable from 3 / 8 to ½ Direction of Rotation Reversible with Switch Overload Protection Electronic Throughout 0 to 95 Rotation Agency Listings UL873 listed CSA 483 0 Certified and/or culus acc. to UL 60730-A/--4, CAN/CSA E60730-:0, CE acc. to 004/08/EEC and 006/95/EC Feedback Signal 0K ohm W Potentiometer Torque Minimum 45 in-lb Running Time 80-0 Seconds. Weight. lb. WattMaster reserves the right to change specifications without notice. All Dimensions are in inches. Three Year Warranty of Form: Orion-OE744-03-OR-0A.doc

OE50-XX-PT Round P.D. Zone Damper Assembly W/ Terminal Block Connectors Description The OE50-XX-PT Round Pressure Dependent Zone Damper Assembly with terminal block connectors consists of a round air damper and the OE74-0P-VAVZ Package with terminal block wiring connectors. An optional Expansion Module (OE35-03) is available for control of reheat, auxiliary heat and/or control of series or parallel flow fan terminal units. The board is microprocessor based and communicates with the HVAC unit controller on the Orion local communications loop. The monitors the space temperature and allocates the proper airflow into its assigned space to achieve the desired comfort and ventilation levels. Damper Blade And Shaft P.D. Zone Damper Housing / Foil Face Insulation Damper Actua Pressure Dependent Zone Dampers are used in air conditioning systems that do not require pressure independent airflow control. If your system requires pressure independent control of Control Base Cover the airflow, see the OE5-XX-PT Round Pressure Independent Zone Damper submittal sheet for the correct specifications. All dampers are tested for performance in accordance with AMCA 500D standards. Mounting The Zone Damper Assembly should be mounted according to standard duct installation practices with airflow direction as shown in the illustration above. After installation of the Zone Damper in the ductwork, insulation should be applied around any remaining un-insulated surface on the damper inlet and outlet. The Zone Damper should be mounted so that the control enclosure is positioned to the left or right side of the ductwork with the control enclosure in a vertical plane. Do not mount the Zone Damper Assembly with the control enclosure on the top or bottom of the ductwork. Adequate clearance should be maintained between the control panel and any obstruction to allow for removal of the control panel cover and access to the controls. Technical Data OE50-XX-PT Round Pressure Dependent Zone Damper Assembly W/ Terminal Block Connectors : Air Damper Construction: Supply Power 4 Volt AC Damper Body 0 Ga. Galv. Steel Power Consumption 6 VA Maximum Damper Blade Round -8 Ga. Galv. Steel Operating Temperature 35 F to 5 F Damper Bearings Stainless Steel Operating Humidity 0-90% RH Non-Condensing Damper Seal EPDM Rubber Gasket Communications RS-485 57600 Baud Leakage < 0 CFM Per Sq. Ft. @ 4 SP Insulation ½ Foil Faced Fiberglass Inputs: Dimensions: Room Temperature Sensor Air Damper Model A B C Setpoint Adjustment OE50-06 (6 ) 3.00 5.88 9.88 Actuator Position Feedback OE50-08 (8 ) 3.00 7.88.3 Communication Connectors: 3 Position Terminal Block OE50-0 (0 ) 3.00 9.88 4.3 Expansion E-BUS Port for Auxiliary Relay Board OE50- ( ) 3.00.88 6.43 E-BUS Port for E-BUS Digital Room Sensor and CO Sensor OE50-4 (4 ) 3.00 3.88 8.50 Actuator Port for Connection to Damper Actuator OE50-6 (6 ) 3.00 5.88 0.56 WattMaster reserves the right to change specifications without notice inches. Three Year Warranty On Electronic Components All Dimensions are in One Year Warranty On Air Damper Form: Orion-OE50XX-PT-RndDmpr-0A Page of

OE50-XX-PT Round P.D. Zone Damper Assembly W/ Terminal Block Connectors Damper Sizing Use a load program to determine the peak load for each zone. These calculations will be used to select Zone Damper sizes. The Orion Systems utilize a typical low pressure duct design. To reduce airflow noise problems, duct pressures generally should not exceed W.C. Primary trunk ducts that are used with Orion systems should not be undersized. This is especially true of pressure dependent systems. With larger trunk ducts, it is easier to assure relatively constant pressure to each Zone Damper. Runs should be as short as possible, and the trunk duct system kept as symmetrical as possible to facilitate system balancing. Wherever possible, run the trunk ducts above corridors and locate the Zone Dampers in the areas above corridors to reduce the noise in the space and to facilitate service of the valves. Trunk ducts should be sized for no more than 0. W.C. drop per 00 ft. of duct, and a maximum duct velocity of 000 FPM. Using the maximum acceptable velocity for a branch duct (typically 000-500 FPM for minimal noise), find the smallest Zone Damper that will deliver the required CFM as determined by the load program. Locate the branch velocity used in the duct design program in the left hand column of the Zone Damper Selection Data table. Move across the table and find the Zone Damper, which will provide the acceptable CFM to meet the zone airflow requirements. Note: Compare the Zone Damper size selected against the duct size to determine if the next size up or down will provide acceptable performance without requiring a transition fitting. Up to a maximum of two Slaved Zone Dampers may be slaved together with the main Zone Damper for large zones. This design should be reserved only for situations when it is not practical to use a single Zone Damper. See the Pressure Independent Zone Damper submittal sheet submittal sheet for information regarding application and selection of Round Slaved Zone Dampers. Zone Damper Selection Data Zone Damper Round Duct Size (Area Ft ) 6 (0.96) OE50-XX-PT Round Pressure Dependent Zone Damper Assembly W/ Terminal Block Connectors 8 (0.349) 0 (0.545) (0.785) 4 (.069) 6 (.396) Velocity Through Damper FPM Airflow Through Damper - CFM ( P S inches W.C. w/ Damper Full Open) 500 750 000 50 500 750 000 98 47 96 (0.05) 45 (0.05) 94 (0.035) 343 (0.045) 39 (0.065) 75 6 349 (0.05) 436 53 (0.035) 6 (0.035) 698 (0.043) 73 409 545 68 (0.05) 88 (0.0) 954 (0.034) 090 (0.040) 393 589 785 98 (0.05) 78 (0.00) 374 (0.030) 570 (0.040) 535 80 069 336 (0.05) 604 0.00) 87 (0.030) 38 (0.040) 698 047 396 745 (0.05) 094 (0.00) 443 (0.05) 79 (0.030) WattMaster reserves the right to change specifications without notice Form: Orion-OE50XX-PT-RndDmpr-0A Page of

OE5-XX-PT Round P.I. Zone Damper Assembly W/ Terminal Block Connectors Description The OE5-XX-PT Round Pressure Independent Zone Damper Assembly with terminal block connectors consists of a round air damper with air flow pickup cross and the OE744-0P-VAVZ Zone Package (including air flow sensor) with terminal block connectors. An optional Expansion Module (OE35-03) is available for control of reheat, auxiliary heat, and/or control of series or parallel flow fan terminal units. Damper Blade And Shaft P.I. Zone Damper Housing / Foil Face Insulation Damper Actuator The board is microprocessor based and communicates with the HVAC unit controller on the Orion local communications loop. The monitors the space temperature and allocates the proper airflow into its assigned space to achieve the desired comfort and ventilation levels. Pressure Independent Dampers are used in air conditioning systems that require pressure independent airflow control. If your system requires pressure dependent control of the airflow, see the Air Flow Pickup Cross Control Base Cover OE50-XX-PT Round Pressure Dependent Zone Damper submittal sheet for the correct specifications. All dampers are tested for performance in accordance with AMCA 500D standards. Mounting The Zone Damper Assembly should be mounted according to standard duct installation practices with airflow direction as shown in the illustration above. After installation of the Zone Damper in the ductwork, insulation should be applied around any remaining un-insulated surface on the damper inlet and outlet. The Zone Damper should be mounted so that the control enclosure is positioned to the left or right side of the ductwork with the control enclosure in a vertical plane. Do not mount the Zone Damper Assembly with the control enclosure on the top or bottom of the ductwork. Adequate clearance should be maintained between the control panel and any obstruction to allow for removal of the control panel cover and access to the controls. Technical Data OE5-XX-PT Round Pressure Independent Zone Damper Assembly W/ Terminal Block Connectors Zone : Air Damper Construction: Supply Power 4 Volt AC Damper Body 0 Ga. Galv. Steel Power Consumption 6 VA Maximum Damper Blade Round -8 Ga. Galv. Steel Operating Temperature 35 F to 5 F Damper Bearings Stainless Steel Operating Humidity 0-90% RH Non-Condensing Damper Seal EPDM Rubber Gasket Communications RS-485-57600 Baud Leakage < 0 CFM Per Sq. Ft. @ 4 SP Inputs: Insulation ½ Foil Faced Fiberglass Air Flow Sensor Dimensions: Room Temperature Sensor Air Damper Model A B C Setpoint Adjustment OE50-06 (6 ) 3.00 5.88 9.88 Actuator Position Feedback OE50-08 (8 ) 3.00 7.88.3 Communication Connectors: 3 Position Terminal Block OE50-0 (0 ) 3.00 9.88 4.3 Expansion E-BUS Port for Auxiliary Relay Board OE50- ( ) 3.00.88 6.43 E-BUS Port for E-BUS Digital Room Sensor and CO Sensor OE50-4 (4 ) 3.00 3.88 8.50 Actuator Port for Connection to Damper Actuator OE50-6 (6 ) 3.00 5.88 0.56 WattMaster reserves the right to change specifications without notice All dimensions are in inches. Three Year Warranty On Electronic Components One Year Warranty On Air Damper Form: Orion-OE5XX-PT-RndDmpr-0A Page of

OE5-XX-PT Round P.I. Zone Damper Assembly W/ Terminal Block Connectors Zone Damper Sizing Use a load program to determine the peak load for each zone. These calculations will be used to select Zone Damper sizes. The Orion Systems utilize a typical low pressure duct design. To reduce airflow noise problems, duct pressures generally should not exceed W.C. Primary trunk ducts that are used with Orion systems should not be undersized. This is especially true of pressure dependent systems. With larger trunk ducts, it is easier to assure relatively constant pressure to each Zone Damper. Runs should be as short as possible, and the trunk duct system kept as symmetrical as possible to facilitate system balancing. Wherever possible, run the trunk ducts above corridors and locate the Zone Dampers in the areas above corridors to reduce the noise in the space and to facilitate service of the valves. Trunk ducts should be sized for no more than 0. W.C. drop per 00 ft. of duct, and a maximum duct velocity of 000 FPM. Using the maximum acceptable velocity for a branch duct (typically 000-500 FPM for minimal noise), find the smallest Zone Damper that will deliver the required CFM as determined by the load program. Locate the branch velocity used in the duct design program in the left hand column of the Zone Damper Selection Data table. Move across the table and find the Zone Damper, which will provide the acceptable CFM to meet the zone airflow requirements. Note: Compare the Zone Damper size selected against the duct size to determine if the next size up or down will provide acceptable performance without requiring a transition fitting. Pressure Independent Zone Dampers may not be slaved together with Slaved-Zone Damper Assemblies. If more than one damper is required for a zone, all dampers must be selected as pressure dependent. See the Pressure Dependent Zone Damper submittal sheet and Slaved-Zone Damper submittal sheets for selection of master/slave damper configurations. Zone Damper Selection Data Zone Damper Round Duct Size (Area Ft ) CFM @ Velocity Pressure (Air Flow Probe K Factor) 6 (0.96) OE5-XX-T Round Pressure Independent Zone Damper Assembly W/ Terminal Block Connectors 8 (0.349) 0 (0.545) (0.785) 4 (.069) 6 (.396) 448 904 436 89 305 3839 Velocity Through Damper FPM Airflow Through Damper - CFM ( P S inches W.C. w/ Damper Full Open) 500 750 000 50 500 750 000 98 47 96 (0.05) 45 (0.05) 94 (0.035) 343 (0.045) 39 (0.065) 75 6 349 (0.05) 436 53 (0.035) 6 (0.035) 698 (0.043) 73 409 545 68 (0.05) 88 (0.0) 954 (0.034) 090 (0.040) 393 589 785 98 (0.05) 78 (0.00) 374 (0.030) 570 (0.040) 535 80 069 336 (0.05) 604 0.00) 87 (0.030) 38 (0.040) 698 047 396 745 (0.05) 094 (0.00) 443 (0.05) 79 (0.030) WattMaster reserves the right to change specifications without notice Form: Orion-OE5XX-PT-RndDmpr-0A Page of

OE736-03-PT P.D. Rectangular Damper Kit w/terminal Blocks Description The OE736-03-PT P.D. Rectangular Damper Kit with Terminal Blocks provides the latest solution for rectangular zone damper applications. The Rectangular Damper Kit is used in conjunction with rectangular dampers for applications where rectangular dampers are specified or required because of space limitations or job requirements. P.D. Zone Enclosure Base Damper Actuator Enclosure Cover The Rectangular Damper Kit includes the OE74-0P-VAVZ Package mounted in a metal enclosure. The rectangular dampers may be purchased from WattMaster or you may get them from the supplier of your choice. For proper control, WattMaster recommends the use of low leakage opposed blade dampers. The maximum allowable damper face area for the Rectangular Damper Kit is 6 sq. ft. Mounting Before mounting the Rectangular Damper Kit, the rectangular damper should be mounted in the ductwork according to standard duct installation practices. The damper should be mounted so the damper shaft turns in a clockwise direction to open the damper. The Rectangular Damper Kit is simply slid over the damper shaft, the actuator shaft collar setscrews tightened and the supplied self-tapping screws are used to mount the enclosure to the ductwork. Detailed mounting and installation instructions are provided with each kit. A knockout is provided in the front access cover, which can be punched out to allow for damper shaft lengths, which extend past the enclosure depth. When mounting the Rectangular Damper Kit, be sure to allow clearance for removal of the access cover. Conduit knockouts are provided in the top and bottom of the enclosure for simplified wiring installation. Component View 5.50 4.5 Dimensional Info Technical Data : OE736-03-PT Rectangular P.D. Damper Kit Features: Supply Power 4 Volt AC Sensors Uses Standard Room Sensor or E-BUS Temp/Humidity Power Consumption 6 VA Maximum Enclosure Material Galvanized Steel Operating Temperature 0 F to 49 F Zone Factory Mounted Operating Humidity 0-90% RH Non-Condensing Zone Actuator Factory Mounted E-BUS Communications RS-485, 57,600 Baud Actuator Rating 45 in/lbs (6 ft Damper Area Max.) Inputs: Actuator Shaft Size Self-Centering - Adjustable from 3 / 8 to ½ Occupied or Window Switch Actuator Direction Reversible with Switch Wire Terminals for E-BUS Digital Room Sensor E-BUS Port for E-BUS Digital Room Sensor of Rotation Outputs: Discharge Temperature Sensor Wire Terminals E-BUS Ports for Expansion Board and/or E-BUS Sensor Actuator Position Feedback Modular Port And Cable For Connection to Actuator WattMaster reserves the right to change specifications without notice Three Year Warranty On Electronic Components One Year Warranty On Air Damper Form: Orion--OE736-03-PT-Rect-PD-VAVZP-0A.doc Page of

OE59 - Rectangular Damper Description The OE59 Rectangular Damper is used in applications where rectangular duct is specified or required because of space limitations or job requirements. The Rectangular Damper utilizes opposed blades of airfoil design for improved air flow control. The Rectangular Damper frame is made of.080 thick extruded aluminum. The blades are also made of extruded aluminum. Blade pins are 7/6 hexagon shaped aluminum fixed to a Celcon inner bearing rotating within a polycarbonate outer bearing inserted in the damper frame. The Damper linkage is mechanically assembled and located in the damper frame. The linkage components are constructed of aluminum, zinc and nickel plated steel. Blade gaskets are made of extruded EPDM material and are secured within an integral slot on the blade. Jamb seals are of extruded TPE material for low leakage through the damper when closed. The control shaft is / diameter hexagon shaped rod and can be extended 9 past the damper frame for connection to the damper actuator. The damper shaft is shipped retracted into the frame area and must be adjusted to the required length in the field. Opposed Blade Profile Flanged to Duct Installation Mounting Dimensional Data The Rectangular Damper should be mounted in the ductwork according to standard duct installation practices. The rectangular damper should be selected for the nominal inside duct size. All Rectangular Dampers are supplied with flanges all around damper frame, making the overall damper width and height larger than the nominal inside duct size thus providing for external flange mounting to ductwork. The damper shaft is shipped retracted into the damper frame. Loosen the two nuts on the U-bolt that secures the damper shaft to the damper blade and adjust to length. It is recommended that the shaft length be adjusted so approximately 4 of shaft extends beyond the inside of the damper frame. Retighten the two nuts on the U-bolt that secures the damper shaft to the blade. After installation of the Rectangular Damper to the ductwork, it is recommended that insulation be applied around any non-insulated surface on the ductwork where the Rectangular Damper was installed. Damper Sizing Use a load program to determine the peak load for each zone. These calculations will be used in selecting the appropriate Rectangular Damper sizes. The Orion Systems utilize a typical low pressure duct design. To reduce noise problems, duct pressures should not exceed W.C. Primary trunk ducts used with Orion systems should not be undersized. This is especially true of pressure dependent systems. With pressure independent systems this is not as critical. With larger trunk ducts, it is easier to assure relatively constant pressure to each Rectangular Damper. Runs should be as short as possible, and the trunk duct system kept as symmetrical as possible to facilitate system balancing. Wherever possible, run the trunk ducts above corridors and locate the Rectangular Dampers above corridors to reduce the noise in the space and facilitate service of the valves. Trunk ducts should be sized for no more than 0. W.C. drop per 00 ft. of duct, and a maximum duct velocity of 000 FPM. Form: ORION-OE59-RectDmpr-Sub-0B.doc Page of

OE59 - Rectangular Damper Using the maximum acceptable velocity for a branch duct (typically 000-500 FPM for minimal noise), find the smallest damper that will deliver the required CFM as determined by the load program. Locate the required CFM on the Rectangular Damper Selection Data table below. This table is based on an airflow velocity of 000 FPM across the damper. This is the recommended velocity for quiet operation and normal pressure drop through the damper. When space considerations or design criteria dictate, dampers may be selected for other face velocities by using the multipliers listed in the notes associated with the table. Move across the table and find the damper selection, which will provide the required CFM and fit within the ceiling area where the damper will be located. Many size selections are possible for a given CFM. Pressure drop across the damper is shown in parenthesis below the CFM. Rectangular Damper Selection Data Damper Height B 8 0 4 6 8 0 4 6 8 30 3 34 36 Damper Width A Airflow Data with Full Open Damper CFM @ 000 FPM Velocity ( P S - inches W.C. @ 000 FPM Velocity) 8 40 (0.6) 0 50 (0.0) 560 (0.07) 4 660 (0.05) 6 750 (0.04) 8 770 (0.03) 0 850 (0.03) 930 4 950 6 990 8 070 30 00 3 090 34 50 36 060 530 (0.0) 590 (0.07) 650 (0.05) 770 (0.03) 890 (0.03) 980 (0.03) 090 0 90 390 500 550 660 770 790 640 (0.07) 690 (0.05) 730 (0.03) 880 030 80 330 480 630 780 930 080 30 380 50 740 (0.05) 800 (0.03) 850 030 00 380 550 730 900 080 50 430 600 780 670 850 (0.04) 90 (0.03) 970 80 370 580 770 980 70 380 570 780 970 380 3090 970 (0.03) 030 090 330 540 780 990 30 440 680 890 330 3340 3580 350 080 (0.03) 50 0 480 70 980 0 480 70 980 30 3480 370 3980 3930 Form: ORION-OE59-RectDmpr-Sub-0B.doc Page of 90 60 330 630 880 80 430 730 980 380 3530 3830 4080 4370 4350 300 380 460 760 060 350 650 950 350 3550 3850 450 4450 4750 5040 40 500 580 90 30 550 870 300 350 3850 470 4500 50 60 700 060 400 750 3090 3450 3790 450 4500 4850 630 730 80 0 570 950 330 3700 4060 4450 740 840 940 360 740 350 3530 3950 4330 4750 850 000 060 50 90 3350 3750 400 4600 NA 970 080 90 640 3090 3540 3990 4440 4880 NA 480 NA NA NA NA NA NA NA 480 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA WattMaster reserves the right to change specifications without notice Notes:. The table above is calculated based on 000 FPM velocity across the full open damper. For other velocities use the following multipliers to obtain the correct CFM: 500 FPM = 0.5, 500 FPM =.5, 000 FPM =.0. It is recommended the damper velocity does not exceed 500 FPM for quiet operation.. Pressure drop ( P S) is based on 000 FPM Velocity. Any pressure drop less than 0.0 W.C. is shown as.

OE737 - Bypass Rectangular Damper Kit Description The OE737 Rectangular Bypass Damper Kit mounts to an OE59 Rectangular Damper and controls duct static pressure to insure proper system airflow. The Rectangular Bypass Damper is controlled by the Orion HVAC Unit. The Unit modulates the Rectangular Bypass Damper in response to the duct static pressure based on a signal received from a static pressure sensor located in the main system ductwork. The Rectangular Bypass Damper Kit is used in conjunction with rectangular dampers for applications where rectangular dampers are specified or required because of space limitations or job requirements. The rectangular dampers may be purchased from WattMaster or you may get them from the supplier of your choice. For proper control, WattMaster recommends the use of low leakage opposed blade dampers. The maximum allowable damper face area for the Rectangular Bypass Damper Kit is 6 sq. ft. The Rectangular Bypass Damper Kit comes packaged with the Damper Actuator and Wiring Interface pre-mounted in a galvanized steel enclosure. Each kit is supplied with mounting hardware and installation instructions. For applications where CFM or space requirements dictate the use of more than a single bypass damper, up to additional bypass dampers can be slaved together. No other components are required. Each bypass is wired to the other bypass damper(s) by means of the Wiring Interface. Mounting Before mounting the Rectangular Damper Kit, the rectangular damper should be mounted in the ductwork according to standard duct installation practices. The damper should be mounted so the damper shaft turns in a clockwise direction to open the damper. The Rectangular Damper Kit is simply slid over the damper shaft, the actuator shaft collar setscrews tightened and the supplied self tapping screws are used to mount the enclosure to the ductwork. Detailed mounting and installation instructions are provided with each kit. A knockout is provided in the front access cover, which can be punched out to allow for damper shaft lengths, which extend past the enclosure depth. When mounting the Rectangular Damper Kit, be sure to allow clearance for removal of the access cover. Conduit knockouts are provided in the top and bottom of the enclosure for simplified wiring. Technical Data OE737 Rectangular Bypass Damper Kit Supply Power 4 Volt AC Enclosure Base Ga. Galv. Steel Power Consumption 3.0 VA Maximum Enclosure Cover Ga. Galv. Steel Operating Temp - F to F Conduit Openings Top - () ½ & ¾ Comb. Knockouts Operating Humidity 90% RH Non-Condensing Bottom - () ½ & ¾ Comb. Knockouts Actuator Feedback 0Kohm, W Potentiometer Shaft Clearance Front - () ½ & ¾ Comb. Knockout Actuator Rating 35 in/lbs (6 ft Damper Area Max.) Controls Factory Mounted Inside Enclosure Mounting Hardware (4) Self Tapping Screws Controls Access Cover is Removable by Instructions Included with Each Kit Loosening Screws Three Year Warranty WattMaster reserves the right to change specifications without notice Form: Orion-OE737-RectBypKit-Sub-0B Page of

Description The OE738 Rectangular Slaved- Damper Kit provides a new solution for rectangular damper applications. The OE738 Rectangular Slaved- Damper Kit is used in conjunction with rectangular dampers for applications in systems when it is not possible or practical to use a single large Rectangular Air Damper to satisfy the zones CFM requirements. OE738 - Slaved- Rectangular Damper Kit The rectangular dampers may be purchased Component View from WattMaster or you may get them from the 5.75 supplier of your choice. For proper airflow control, WattMaster recommends the use of low 3.5 leakage opposed blade dampers. The Rectangular Slaved- Damper Kit is supplied 8.0 with the slave wiring interface card and actuator factory mounted in a sheet metal enclosure. A total of two Slaved- Air Dampers may.5 be used in conjunction with a master Rectangular Damper Kit. The Rectangular Slaved- Air Damper(s) are wired in Dimensional Data parallel with the master Rectangular Damper Kit and track the movement of the master Rectangular Damper. Connection to the master Rectangular Damper Kit requires a Slave Wiring Adapter Kit, part # OE67 which is supplied with each Rectangular Slaved- Damper Kit. The kit connects the zone controller on the master to the master actuator and provides wiring terminals for wiring to the Rectangular Slaved- Damper Kit(s). Only one Slaved Wiring Kit is required for each Slaved- system. Each kit is supplied with mounting hardware and installation instructions. Mounting The rectangular damper should be mounted in the ductwork according to standard duct installation practices before installing the Rectangular Slaved- Damper Kit. The Rectangular Slaved- Damper Kit is simply slid over the damper shaft, the actuator shaft collar setscrews tightened and the supplied self tapping screws are used to mount the enclosure to the ductwork. Detailed mounting and installation instructions are provided with each kit. A knockout is provided in the front access cover, which can be punched out for damper shaft lengths which extend past the enclosure depth. When mounting the Rectangular Slaved- Damper Kit, be sure to allow clearance for removal of the access cover. Conduit knockouts are provided in the top and bottom of the enclosure for simplified wiring installation. Technical Data Actuator: OE 738 Rectangular Slaved-Zone Damper Kit OE 738 Damper Kit Features: Supply Power 4 Volt AC Enclosure Base Ga. Galv. Steel Power Consumption 3.4 VA Maximum Enclosure Cover Ga. Galv. Steel Operating Temperature 0 F to 49 F Conduit Openings Top - () ½ & ¾ Comb. Knockouts Operating Humidity 90% RH Non-Condensing Bottom - () ½ & ¾ Comb. Knockouts Shaft Clearance Front - () ½ & ¾ Comb. Knockout Inputs: Controls Factory Mounted inside the Enclosure Actuator Position Feedback Mounting Hardware Supplied with (4) Self Tapping Screws Instructions Included with Each Kit Controls Access Cover is Removable by Loosening Screws Actuator Rating 35 in/lbs (6 ft Damper Area Max.) WattMaster reserves the right to change specifications without notice Three Year Warranty Form: Orion-OE738-RectSlvZoneKit-SUB-0B Page of

Description The OE8-03 Slaved Damper Kit consists of an OE8 Damper Actuator, () PL084 Slave Wiring Interface Boards and () 8 Long Modular Cables. The OE8 Actuator is a shaft mounted, floating point control actuator. The actuator is a 4VAC/4VDC model with a 0K ohm feedback signal for position monitoring. Wiring connection to the actuator is by means of a modular phone cable connector located on the actuator cover. The actuator is rated for 45 inlb. of torque. All actuators are electronically protected against overload. The angle of rotation is mechanically limited to 95. When the end position of the actuator or damper is reached, the actuator automatically stops. For adjustment purposes, the gears can be manually disengaged by pushing the manual override button on the actuator cover. OE8-03 Slaved Damper Kit Applications The OE8-03 Slaved Damper Kit allows multiple dampers (up to total besides the master) to be connected to a master OE74-3-VAVZ or OE74-3-VAVZ P.D. Actuator Package. The OE8-03 Kit is typically used when larger CFM requirements dictate multiple dampers are used. One of the Interface Boards connects to the master via a modular cable. The other Interface Board connects to the Slave Damper Actuator. Three conductor wiring is then routed and connected between the two Interface Boards. For zones requiring more than one Slave Damper Kit a second one can be purchased and installed in the same manner. Technical Data OE8-03 Slaved Damper Kit Actuator Power 4VAC 0% 50/60HZ Actuator Angle of Rotation Max. 95, Adjustable Supply Actuator Life Cycle.5 Million Cycles with Mechanical Stops Rating Actuator Power 3 VA Maximum Power Connections RJ- Modular Jack Consumption Operating Temp - F to F Servicing Maintenance Free Operating Humidity 5 to 95% RH Non- Actuator Quality Standard ISO 900 Condensing Actuator Overload Protection Electronic Throughout 0 to 95 Rotation Actuator Agency Listings UL873 listed CSA 483 0 Certified Actuator Feedback 0K ohm W Actuator Torque Minimum 45 in-lb. Signal Potentiometer Actuator Running 80-0 Seconds. Approx. Kit Weight. lb. Time PL084 Board () RJ- Modular Jacks PL084 Board () Wiring Terminal Blocks Three Year Warranty WattMaster reserves the right to change specifications without notice Form: Orion-OE8-03-SlvZoneDmprKit-Sub-0A.doc Page of

Worksheet Project Name: Local Loop Number: Directions: Estimate cable lengths from building mechanical plans and place in estimated cable length column beside each controller or board on loop. Select available cable lengths closest to estimated cable lengths and extensions for each controller or board on list and place checkmarks in these columns. Also Use this information for ordering correct quantity and length of modular or digital cables and extensions. Total each cable length column on each page and add both page totals together. Address Or Board Description, Location Or Tag Number Incoming Cable Length 3 Ft. 5 Ft. Available 40 Ft. 80 Ft. 0 Ft. E-0 Ft. E-0 Ft. Incoming Modular Or Digital Room Sensor Cable Length 5 Ft. Available Modular Or Digital Room Sensor See Notes Below 0 Ft. 5 Ft. 40 Ft. 80 Ft. 0 Ft. 60 Ft. N/A Power Comm Board Caution: Each board has a total of 4 branch circuits. No more N/A Power Comm Board than 6 modular devices are allowed per branch circuit. No more than 6 modular devices total can be connected to each N/A Power Comm Board 3 board. The longest total run per branch circuit is 40 Feet. N/A Power Comm Board 4 3 4 5 6 7 8 9 0 3 4 5 6 7 8 9 3 4 5 6 7 8 Page Totals Notes:.) Available cable lengths with the prefix E (E-0 Ft. or E-0 Ft.) are extensions to be used in conjunction with another standard cable length to extend it to a desired length, they cannot be used by themselves without connection to a standard cable..) Available Modular Sensor cable lengths are provided in 5 Ft, 0 Ft., 5 Ft., 40 Ft. and 80 Ft. Lengths. To get longer lengths you can join Modular cables together using the MS00009 Modular Room Sensor Cable Coupler to extend the cables to a desired length in between or greater than the standard cable sizes. Available Digital Sensor cable lengths are provided in 5 Ft., 0 Ft., 5 Ft., 40 Ft., 80 Ft., 0 Ft. and 60 Ft. sizes. You can join Modular cables together using the MS00009 Modular Room Sensor Cable Coupler to extend the cables to a desired length in between the available sizes. It is recommended that you avoid this when using the Digital Sensor cable. The maximum allowable total cable length for Digital Sensor cables is 60 Ft. and should never be exceeded. Form: Orion-VAVZoneCableEst-All-A.doc Page of 77

Worksheet Project Name: Local Loop Number: Directions: Estimate cable lengths from building mechanical plans and place in estimated cable length column beside each controller or board on loop. Select available cable lengths closest to estimated cable lengths and extensions for each controller or board on list and place checkmarks in these columns. Also Use this information for ordering correct quantity and length of modular or digital cables and extensions. Total each cable length column on each page and add both page totals together. Address Or Board Description, Location Or Tag Number Incoming Cable Length 3 Ft. 5 Ft. Available 40 Ft. 80 Ft. 0 Ft. E-0 Ft. E-0 Ft. Incoming Modular Or Digital Room Sensor Cable Length 5 Ft. Available Modular Or Digital Room Sensor See Notes Below 0 Ft. 5 Ft. 40 Ft. 80 Ft. 0 Ft. 60 Ft. 9 30 3 3 33 34 35 36 37 38 39 40 4 4 43 44 45 46 47 48 49 50 5 5 53 54 55 56 57 58 Page Totals Totals For Both Pages Notes:.) Available cable lengths with the prefix E (E-0 Ft. or E-0 Ft.) are extensions to be used in conjunction with another standard cable length to extend it to a desired length, they cannot be used by themselves without connection to a standard cable..) Available Modular Sensor cable lengths are provided in 5 Ft, 0 Ft., 5 Ft., 40 Ft. and 80 Ft. Lengths. To get longer lengths you can join Modular cables together using the MS00009 Modular Room Sensor Cable Coupler to extend the cables to a desired length in between or greater than the standard cable sizes. Available Digital Sensor cable lengths are provided in 5 Ft., 0 Ft., 5 Ft., 40 Ft., 80 Ft., 0 Ft. and 60 Ft. sizes. You can join Modular cables together using the MS00009 Modular Room Sensor Cable Coupler to extend the cables to a desired length in between the available sizes. It is recommended that you avoid this when using the Digital Sensor cable. The maximum allowable total cable length for Digital Sensor cables is 60 Ft. and should never be exceeded. Form: Orion-VAVZoneCableEst-All-A.doc Page of 78