NIAGARA. Series WPX. Installation, Operation & Maintenance Manual. Models 210 and 222. Series WPX

Similar documents
MTX and WPX Turbine Flowmeters

M SERIES Multi-Jet Cold Water Meter

Industrial Turbo Meters, Sizes 2" through 6"

IMPORTANT!!!! Read this manual before attempting any installation, wiring or operation.

EZ-IN Series Turbine Flowmeter

25 mm (1 in), 38 mm (1-1/2 in) & 50 mm (2 in) TYPE S FLOWMETERS WITH MODEL 157 AND 800 SERIES REGISTERS

TX80-Series FLOW SENSOR INSTRUCTIONS TX81 TX :2008 ISO CERTIFIED COMPANY TX80-SERIES FLOW SENSOR INSTRUCTIONS

ZTM AND ZTMB ZENNER TURBINE METERS INSTALLATION, MAINTENANCE AND SERVICING

A1 Commercial Grade Meters

The full WeatherTRAK Flow3 Installation and Maintenance Manual is available online at

PRESSURE REDUCING VALVE

OMP POSITIVE DISPLACEMENT FLOWMETERS

Features/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS

INSTALLATION, OPERATION AND MAINTENANCE Threaded and Wafer Style Flowmeters

OMP Positive Displacement Flowmeters

PRESSURE REDUCING CONTROL VALVE

Mustang Series PRESSURE REDUCING CONTROL VALVE. M115 (Globe) M1115 (Angle) Schematic. Standard Components. Options & Accessories.

IP80-Series FLOW SENSOR INSTRUCTIONS IP81 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

Temperature: TYPE A (1" 3") TYPE B (1/2" TYPE C (1/2" 4") TYPE D (3"

G2 SERIES INDUSTRIAL GRADE METERS

PRESSURE REDUCING VALVE

G2 Industrial Grade Meters

PRESSURE REDUCING VALVE

MULTI-JET WATER METERS

A1 SERIES COMMERCIAL GRADE METERS A1 SERIES COMMERCIAL GRADE METERS

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

TURBINE METERS - WP Series

Technical Data. Series Oval Flowmeter. Model 9400

Constant Flow Valves. Specifications Sizes: PVC: 1/2", 3/4", 1", 2", 3", 4" CPVC: 1" and 2" Body: Bonnet: Models: Seals: Springs:

LEAD FREE * LFM115 (Globe) LFM1115 (Angle)

INSTALLATION INSTRUCTIONS FOR THE TRUCK MOUNTED VIPER ADDITIVE INJECTION SYSTEM GTP-8776C

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP800-SERIES FLOW SENSOR INSTRUCTIONS

BM SERIES METERS PRECISION POSITIVE DISPLACEMENT METERS THE LEADER IN ACCURATE, LONG-LIFE, FUEL METERING INDUSTRY LEADING ACCURACY (+/-.

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

HYDROMETERS OPERATION, INSTALLATION & MAINTENANCE GUIDE

LEAD FREE * LFF115 (Globe) LFF1115 (Angle)

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

TX 115/215 Hot-tap Insertion Turbine Instructions

NC State University Design and Construction Guidelines Division 23 Energy Management

TX800-Series FLOW SENSOR INSTRUCTIONS. TX81x TX82x 9 001:2008 ISO CERTIFIED COMPANY TX800-SERIES FLOW SENSOR INSTRUCTIONS

TRU/FLO Compound Installation and Maintenance Guide

Constant Flow Valves. Specifications PVC: 1/2", 3/4", 1", 2", 3", 4" PVC PVC Flanged ANSI EPDM Stainless Steel 304 with ETFE Coating º F

A1 Commercial Grade Meters

Series Roll Seal

FPD1000-HP SERIES HIGH PRESSURE Positive Displacement Flowmeters

IP800-Series. Insertion Paddlewheel Flow Sensor Instructions PROUDLY MADE IN THE USA

SECTION ELECTRONIC ACTUATED PRESSURE REDUCING VALVES AND ACCESSORIES

TX115/215 Hot-tap Insertion Turbine Instructions

Technical Data B20x. 8 BiRotor, APL. Model B201 [8 ] Model B203 [8 ] Model B204 [8 ] Model B205 [8 ]

neptunetg.com Neptune Technology Group Inc Alabama Highway 229 Tallassee, AL USA Tel: (800) Fax: (334)

TX101/201 Insertion Turbine Instructions

FLOW METERS FOR MINING

Operation and Maintenance Manual

HP Turbine Installation and Maintenance Guide

LACT MEASUREMENT. Total Head = Or PSI = S.G. 2.31

BI-DIRECTIONAL INSERTION FLOW TRANSDUCER

Liquid Turbine Flowmeter

VALVCHEQ BACKFLOW PREVENTERS FIGURE DC03

Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA

Instruction Manual RZ POSITIVE DISPLACEMENT FLOWMETERS 2AU

LEVEL AND FLOW MEASUREMENT WS131 FLOW METER USER MANUAL.

FPD1001 thru FPD1003, FPD1102 and FPD1103, FPD1201 thru FPD1203 (includes -R Option) Positive Displacement Flowmeters

KEL DIFFERENTIAL PRESSURE FLOWMETERS

Instruction Manual. RZ Positive Displacement Flowmeters 2AU

Wafer Silent Check Valves

IP800-Series. Insertion Paddlewheel Flow Sensor Instructions PROUDLY MADE IN THE USA

DESIGN, OPERATION & MAINTENANCE OF L.A.C.T. UNITS

TX101/201 Insertion Turbine Instructions

Flow Measurement & Control Solutions

Propeller Meters. Flow measurement solutions for water and wastewater

XP-300 Series Sprinklers Installation & Service Instructions

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

RCM - Direct Reading Flowmeters

OVAL GEAR. Large Capacity Positive Displacement Mechanical Flowmeters. Models: 3 (D-750), 3 (D-1000), 4 (D-1500) & 4" (D-2500)

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

Electric Fuel Pump FPM

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

EX80 Series EX81 EX82. E X 8 0 S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s. The Leader in Flow Meter Value.

S-Series. Low Flow Meter Instructions SPX SPT. Precision Flow Measurement An ONICON Brand PROUDLY MADE IN THE USA

Model 5000 Vortex Meter

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter

User Manual. Recordall Compound Series Meter. Lead-Free Bronze Alloy, Sizes 2", 3", 4" & 6" NSF/ANSI Standards 61 and 372 Certified

FIXED DEPTH INSERTION METER INSTRUCTIONS

Signet 2517 Brass Paddlewheel Flow Sensor * *

TYPE MP OSCILLATING PISTON FLOWMETER

OVAL GEAR Medium capacity positive displacement Mechanical flowmeters. Model: ½ (15m m)

Flow Control Valve IOM 770-U

DWS 41. Installation Data 44 Performance Specs DWS & DW-PRV Series

M-3025CB-AV Fuel Pump

ARCHIVED. EX80 Series. (Includes Dates 6/28/05 to 10/06) EX81 EX82

Colt Series C400, C500

Technical Data P3 PISTON POWER PUMP NON-ELECTRIC CONDENSATE PUMP SD 9952B

NO ENTRY No entry for Models 605, 610 or 620. Enter maximum flow rate for Model 600 with external flow sensor

MidFlow _ 135. Sliding Vane Meters DN (1-2 ) Model PT / Fuel Oil Flowmeters135. Product Bulletin

Sanitary Turbine Flow Meter - TA3 Installation, Operating & Maintenance Manual

TECHNICAL CHARACTERISTICS

ZDM Positive Displacement Flow Meter User Instructions

WATER METERS OCTAVE ULTRASONIC WATER METER INSTALLATION & USER GUIDE

Industrial Turbo Meters. Sizes 2 in. through 6 in. User Manual. TUR-UM EN-21 (October 2017)

Transcription:

NIAGARA M212 Rev. F Series WPX Models 210 and 222 Installation, Operation & Maintenance Manual Model 210 hot Sizes 2, 3, and 4 Sizes 6, 8, and 10 (red) Models 222 cold Sizes 2, 3, and 4 Sizes 6, 8, and 10 (dark gray)

Table of Contents Model 210 Hot Water Installation & Operation... 1 General... 1 Installation... 1 Operation... 1 Options... 1 Model 210 Maintenance... 2 Register Removal... 2 Removing Measuring Chamber... 2 Installation of Measuring Chamber... 2 Replacement Parts... 3 Model 222 Cold Water Installation & Operation... 4 General... 4 Installation... 4 Operation... 4 Options... 4 Model 222 Maintenance... 5 Register Removal... 5 Removing Measuring Chamber... 5 Installation of Measuring Chamber... 5 Replacement Parts... 6 Models 210 and 222 Specifications... 6

Model 210 Hot Water Installation & Operation GENERAL The red Niagara Series WPX turbine flowmeters are ideal for the measurement of water up to 250 F in commercial and industrial applications. These high performance meters are unsurpassed in the market place today. INSTALLATION The Niagara Series WPX turbine meter may be mounted in a horizontal or vertical pipe, but never with the register on the bottom. In order to have accurate measurement, the meter must have 5 pipe diameters upstream and 3 pipe diameters downstream of straight uninterrupted pipe. The WPX turbine must be placed in a pipeline free of scale, sediment, and debris. If there is excessive sediment in the pipeline, protect the meter by putting a strainer (20 mesh) upstream of the meter. OPERATION Air must be evacuated from the WPX turbine before operating. Slowly open valve to let water into the meter. Gradually increase the flow rate to drive out the air. If the meter is not filled slowly, the surge of water can damage the measuring elements. OPTIONS Model 860 Provides a high frequency pulse output for interface with Venture Measurement instrumentation. Supply Voltage: 30 VDC max. Current Requirement: 15-20 ma. Output Signal: Non-symmetrical square pulse train (equal to supply voltage). Wiring: Pigtail, 36, 3-wire conductor. Max. Output Current: 20 ma. Model 840 Provides a calibrated contact closure. Contact Rating Switching Voltage: 30 VDC max. Current DC Resistive 0.2A max. Wattage: 3 WDC max. Wiring: Pigtail, 36, 22 gauge 1

Model 210 Maintenance REGISTER REMOVAL Model 210 Totalizer with Reed Switch and Infrared Transmitter 1. Remove strain relief nut and draw out washer and binding nut. 2. Remove screws from register cover. 3. Remove register cover. 4. Slide reed switch or infrared transmitter out of the dovetail slot in the register. 5. Remove sealing wire out of sealing segment and working clamp ring. 6. Pull sealing segment out of ring. 7. Turn working clamp ring and register 90 degrees to the left or the right and lift off. 8. The register cannot be disassembled further. It is hermetically sealed and must be replaced as a unit if damaged. Straight Totalizer 1. Remove the fillister head screws from the register cover and lift off cover. 2. Remove sealing wire. 3. Lift of sealing segment. 4. Turn clamp ring 90 degrees to the left or the right and lift it up with the counter. REMOVING MEASURING CHAMBER Model 210 Sizes 2, 3, 4, 6 & 8 1. Loosen sealing wire. 2. Remove hex head screws. 3. Lift out measuring chamber housing. 4. If measuring unit is stuck, loosen it by prying on the cast recesses with a screw driver. 5. Check O-Ring for damage. Replace if necessary. Model 210 Size 10 1. Loosen sealing wire. 2. Remove hex screws. 3. Grip measuring chamber housing by the two lifting eye bolts and lift out. 4. Check O-Ring for damage and wear. Replace if necessary. INSTALLATION OF MEASURING CHAMBER 2 Model 210 Install the Model 210 by following the reverse order of the removal instructions. The following items should be checked: O-rings and lip washers should be checked for damages before installation. Slightly lubricate O-rings and regulator shaft. The slot of regulator drive has to be in line with the regulator vane in the starting position.

REPLACEMENT PARTS Measuring chamber complete Register assembly Note: Part numbers are listed in the parts price book. Model 210 1 strain relief nut 2 register cover screws 3 register cover 4 reed switch or infrared transmitter 5 sealing wire 6 sealing segment 7 working clamp ring 8 sealing wire 9 hex head screws 10 measuring chamber housing 11 o-ring 3

Models 222 Cold Water Installation & Operation GENERAL The blue Niagara Series WPX turbine flowmeters are ideal for the measurement of water up to 120 F in commercial and industrial applications. These high performance meters are unsurpassed in the market place today. INSTALLATION The Niagara Series WPX turbine meter may be mounted in a horizontal or vertical pipe, but never with the register on the bottom. In order to have accurate measurement, the meter must have 5 pipe diameters upstream and 3 pipe diameters downstream of straight uninterrupted pipe. The WPX turbine must be placed in a pipeline free of scale, sediment, and debris. If there is excessive sediment in the pipeline, protect the meter by putting a strainer (20 mesh) upstream of the meter. OPERATION Air must be evacuated from the WPX turbine before operating. Slowly open valve to let water into the meter. Gradually increase the flow rate to drive out the air. If the meter is not filled slowly, the surge of water can damage the measuring elements. OPTIONS Model 573 Provides a high frequency pulse output for interface with Venture Measurement instrumentation. Supply Voltage: 24 VDC max. Current Requirement: 30 ma. Output Signal: Non-symmetrical square pulse train (equal to supply voltage). Wiring: Pigtail, 36, 3-wire conductor. Max. Output Current: 30 ma. Model 840 Provides a calibrated contact closure. Contact Rating Switching Voltage: 30 VDC max. Current DC Resistive 0.2A max. Wattage: 3 WDC max. Wiring: Pigtail, 36, 22 gauge 4

Models 222 Maintenance REGISTER REMOVAL Model 222 1. Depress the tab in the register box below the hinge. Lift hinged side of register and rotate forward to remove it from the meter. 2. Remove the sealing tape from the locking segment and register retaining ring. Remove the locking segment from the retaining ring by prying straight up on the locking segment with a flat screwdriver. 3. Spread the retaining ring to remove it from the slot on the top case and remove it. Lift register off top case. 4. To re-assemble, reverse the order of the instructions above. REMOVING MEASURING CHAMBER Model 222 Sizes 2, 3, 4, 6, 8, & 10 1. Remove the sealing wire from the case bolts. Loosen the case bolts and remove them. 2. Lift top case and measuring chamber from the bottom casing. 3. Remove the rubber lip seal from the inlet side of the measuring chamber to expose the 3rd screw. 4. Remove the 3 screws securing the measuring chamber to the top case. 5. To replace the measuring chamber, reverse the order of instructions above. Note: The lip seal and casing O ring should be inspected before re-assembly. Any worn or torn seals should be replaced. 5

REPLACEMENT PARTS Measuring chamber complete Register assembly Note: Part numbers are listed in the parts price book. Models 210 (hot) Specifications Size 2 3 4 6 8 10 Flow Rate gpm 8-305 20-660 30-1100 45-1870 60-2860 80-4400 Pressure psi 227 227 227 227 227 227 Temperature 250 F 250 F 250 F 250 F 250 F 250 F Accuracy ± 1% ± 1% ± 1% ± 1% ± 1% ± 1% Registration* USG USG USG USG USG USG Gallons per contact 10 100 100 100 100 1000 with 840 Switch or 100 or 1000 or 1000 or 1000 or 1000 or 10000 Full Scale Freq. Hz 50.8 22 36.67 31.15 47.7 14.67 with 860 Infra-Red Pulser Pulses per Gallon* 10 2 2 1 1.2 Models 222 (cold) Specifications Size 2 3 4 6 8 10 Flow Rate gpm 4.4-396 3.5-880 7.9-1321 17.6-1541 26.4-2862 88-5284 Pressure psi 227 227 227 227 227 227 Temperature 120 F 120 F 120 F 120 F 120 F 120 F Accuracy ± 1% ± 1% ± 1% ± 1% ± 1% ± 1% Registration* USG USG USG USG USG USG Gallons per contact 10 100 100 100 100 1000 with 840 Switch or 100 or 1000 or 1000 or 1000 or 1000 or 10000 Full Scale Freq. Hz 66 14.7 22 26.7 47.7 8.8 with 573 Infra-Red Pulser Pulses per Gallon* 10 1 1 1 1.1 * Other units of registration available (consult factory). Hz = GPM x PPG PPG = Hz x 60 60 GPM Wetted Material of Construction Body: Cast Iron Measuring Element: 120 F - Noryl 250 F - Polyethersulfone Rotor: Polyamid O-Ring Seals: EPDM NIAGARA 150 Venture Boulevard Spartanburg, SC 29306 Phone: (800)778-9251, (864) 574-3327 Fax: (864) 574-8063 Internet: www.aaliant.com E-Mail: sales@aaliant.com A Product Line M212 Rev. F 11/04