Diesel generator set QSK95 series engine

Similar documents
Diesel Generator set QSK95 series engine

Diesel Generator set QSK95 series engine

Diesel generator set QSK60 series engine

Diesel generator set QSK60 series engine

Diesel generator set QSK60 series engine

Diesel generator set QSK78 series engine

Diesel generator set QST30 series engine

Diesel generator set QSK60 series engine

Diesel generator set QSK78 series engine

Diesel Generator set QSK50 series engine 1135 kw-1500 kw 60 Hz EPA emissions

Tier4 certified diesel generator set QSK50 series engine

Diesel generator set QSX15 series engine

Diesel generator set QSK23 series engine

Diesel generator set QSK50 series engine

Tier4 certified diesel generator set QSK78 series engine

Diesel generator set QSX15 series engine

Diesel generator set QSK23 series engine

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz

Diesel generator set 6BT5.9 series engine

Diesel generator set QSB7 series engine

Diesel generator set 4BT3.3 series engine

Diesel generator set QSL9-G7 series engine

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz Data Center Continuous

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

Rental Power QSL9 series engine

Spark-ignited generator set

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

Rental Power QSB7 series engine

Spark-ignited generator set

Diesel generator set QSL9 series engine

Rental Power 1500 kw. Specification sheet. Description. Features. Options

Spark-ignited generator set

Rental Power KTA50 G3 series engine

Diesel generator set B3.3 series engine 44 kva - 66 kva 50 Hz 40 kw - 60 kw 60 Hz

Rental Power 800 kw. Specification sheet. Description. Features. Options

Model DFEH 60 Hz EPA Emissions

Diesel Generator Set S3.8 Series Engine

2000kW Rental Package

Diesel Generator Set Model DGDB 60 Hz

Diesel generator set QSL9 series engine

Diesel Generator Set Model DFCE 60 Hz

Diesel Generator Set Model DFBF 60 Hz

Spark-Ignited Generator Set Model GGLA 60 Hz

Rental Power 4BTAA3.3 series engine

Spark-Ignited Generator Set Model GGFD 60 Hz

Model DSHAE 60 Hz EPA Emissions

Model DKAC 60 Hz EPA Emissions

Diesel Generator Set Model DSHAD 60 Hz EPA Emissions

Rental Power Kubota V2403 series engine

Gaseous Fuel Generator Set Model GFDA

Diesel Generator Set Model DFHB 60 Hz

Diesel Generator Set Model DFJD 60 Hz

Gaseous Fuel Generator Set QSK19G Engine Series

Gaseous Fuel Generator Set KTA19G Engine Series

Spark-Ignited Generator Set Model GGKD 60 Hz

Diesel generator set C17D5T series

Spark-Ignited Generator Set Model GGKC 60 Hz

Model DFHD 60 Hz EPA Emissions

KTA50 Land Based Drilling Power Modules

Power Connect TM Series RX60

Power Connect RX50. Series. Specification sheet. Features and benefits. Weight, size and sound level

PowerCommand 1.1 control system

PowerCommand. Digital Generator Set Control

PowerCommand Digital generator set control

100 KW(NG) / 100 KW(LP) LIQUID COOLED POWERED by

2000 KW / 2500 KVA POWERED by

Gaseous Fuel Generator Set GTA19 Engine Series

300 KW / 375 KVA POWERED by

PowerCommand 3300 Control Panel. Our Energy Is Working For You.

28 KW / 28 KVA POWERED by

55 KW / 70 KVA POWERED by

20 KW / 25 KVA LIQUID COOLED POWERED by

Gaseous Fuel Generator Set GTA28 Engine Series

Gaseous Fuel Generator Set GTA50 Engine Series

130 KW / 165 KVA POWERED by

1800 KW / 2250 KVA POWERED by

600 KW / 750 KVA POWERED by

DIESEL GENERATOR SETS

PowerCommand 2100 digital generator set control

640 KW / 800 KVA POWERED by

PowerCommand. GenSet Controls

60 KW / 75 KVA. POWERED by. kva 75 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 70 Prime Power Factor 0.8 kw 55

1020 KW / 1275 KVA. POWERED by TP-U1275-T2F-60. kva 1275 Standby 3 Phase - Switchable kw /208, 277/480. kva 1150 Prime Power Factor 0.

19 KW / 24 KVA POWERED by

275 KW / 344 KVA. POWERED by TP-JD275-T3F-60. kva 313 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 224 Prime Power Factor 0.

130 KW / 165 KVA POWERED by

16 KW / 20 KVA POWERED by

64 KW / 80 KVA POWERED by

18 KW / 18 KVA POWERED by

A Single Source for all Power System Solutions

45 KW / 55 KVA POWERED by

400 KW / 500 KVA. POWERED by TP-JD400-T3-60-UL. kva 500 Standby 3 Phase kw /208, 110/220, 120/240, 277/480

DIESEL GENERATOR SET FEATURES

80 KW / 100 KVA POWERED by

700 KVA / 550 KW POWERED by

D I E S E L G E N E R A T O R S E T S

DIESEL GENERATOR SET. 60 Hz FEATURES

1000 KW / 1250 KVA POWERED by

PowerCommand. GenSet Controls. Digital Paralleling Control

Transcription:

Specification sheet Diesel generator set QSK95 series engine 2750 kw - 3350 kw 60 Hz Data Center Continuous EPA Tier 2 emissions regulated Description Cummins commercial generator sets are fully integrated power generation systems providing optimum performance, reliability and versatility for data center applications. Features Data Center Continuous (DCC) - Applicable for supplying power continuously to a constant or varying electrical load for unlimited hours in a data center application. Uptime Compliant - Meets the requirement of a Tier III and IV data center site by being rated to run for unlimited hours of operation when loaded to 'N' demand for the engine generator set. Cummins heavy-duty engine - Rugged 4- cycle, industrial diesel delivers reliable power, low emissions and fast response to load changes. Alternator - Several alternator sizes offer selectable motor starting capability with low reactance windings, low waveform distortion with non-linear loads and fault clearing shortcircuit capability. Control system - The PowerCommand digital control is standard equipment and provides total genset system integration including automatic remote starting/stopping, precise frequency and voltage regulation, alarm and status message display, AmpSentry protective relay, output metering and auto-shutdown. Cooling system - Standard and enhanced integral set-mounted radiator systems, designed and tested for rated ambient temperatures, simplifies facility design requirements for rejected heat. Also optional remote cooled configuration for non-factory supplied cooling systems. Warranty and service - Backed by a comprehensive warranty and worldwide distributor network. NFPA - The generator set accepts full rated load in a single step in accordance with NFPA 110 for Level 1 systems. Model 60 Hz kw (kva) Data sheets 60 Hz C3000 D6e 2750 (3438) NAD-5942-DC C3250 D6e 3000 (3750) NAD-3527-DC C3500 D6e 3350 (4188) NAD-5917-DC Note: All ratings include radiator fan losses.

Generator set specifications Governor regulation class Voltage regulation, no load to full load ± 0.5% Random voltage variation ± 0.5% Frequency regulation ISO8528 Part 1 Class G3 Isochronous Random frequency variation ± 0.25% Radio frequency emissions compliance Engine specifications Bore Stroke 47 CFR FCC PART 15 Subpart B (Class A for industrial) 190 mm (7.48 in) 210 mm (8.27 in) Displacement 95.3 litres (5815 in 3 ) Configuration Battery capacity Battery charging alternator Starting voltage Fuel system Fuel filter Fuel transfer pump Breather Air cleaner type Lube oil filter type(s) Standard cooling system Alternator specifications Design Stator Rotor Insulation system Standard temperature rise Exciter type Phase rotation Alternator cooling AC waveform Total Harmonic Distortion (THDV) Telephone Influence Factor (TIF) Telephone Harmonic Factor (THF) < 3 Anti-condensation heater Available voltages 220/380 7200/12470 2400/4160 240/416 277/480 7620/13200 255/440 347/600 7970/13800 Note: Consult factory for other voltages. Cast iron, V 16 cylinder 6 x 1400 amps minimum at ambient temperature of -18 C (0 F) 145 amps 24 volt, negative ground Cummins modular common rail system On engine triple element, 5 micron primary filtration with water separators, 3 micron/2 micron (filter in filter design) secondary filtration. Electronic variable speed priming and lift pump Cummins impactor breather system Unhoused dry replaceable element Spin-on combination full flow filter and bypass filters High ambient cooling system (ship loose) Brushless, 4 pole, drip proof, revolving field Optimal Two bearing, flexible coupling Class H on low voltage and medium, Class F on high voltage 125 ºC Standby/105 ºC Prime Optimal A (U), B (V), C (W) Direct drive centrifugal blower fan < 5% no load to full linear load, < 3% for any single harmonic < 50 per NEMA MG1-22.43 1400 watt Generator set options and accessories Engine 480 V thermostatically controlled coolant heater for ambient above 4.5 C (40 F) Heavy duty air cleaner Redundant fuel filter Air starter Redundant electric starting Eliminator oil filter system Lube oil make up Coalescing breather filter Alternator 80 C rise 105 C rise 125 C rise 150 C rise Differential current transformers Cooling system Enhanced high ambient cooling system (ship loose) Remote cooled configuration Control panel Multiple language support Ground fault indication Remote annunciator panel Paralleling and shutdown alarm relay package Floor mounted pedestal installed control panel

Generator set options and accessories (continued) Generator set Battery Battery charger LV and MV entrance box Spring isolators Factory witness tests IBC, OSHPD, IEEE seismic certification Warranty 3, 5, or 10 years for standby including parts (labor and travel optional) 2 or 3 years for prime including parts, labor and travel Note: Some options may not be available on all models - consult factory for availability. PowerCommand 3.3 control system An integrated microprocessor based generator set control system providing voltage regulation, engine protection, alternator protection, operator interface and isochronous governing. Refer to document S-1570 for more detailed information on the control. AmpSentry Includes integral AmpSentry protection, which provides a full range of alternator protection functions that are matched to the alternator provided. Power management Control function provides battery monitoring and testing features and smart starting control system. Advanced control methodology Three phase sensing, full wave rectified voltage regulation, with a PWM output for stable operation with all load types. Communications interface Control comes standard with PCCNet and Modbus interface. Regulation compliant Prototype tested: UL, CSA and CE compliant. Service - InPower PC-based service tool available for detailed diagnostics, setup, data logging and fault simulation. Easily upgradeable PowerCommand controls are designed with common control interfaces. Reliable design The control system is designed for reliable operation in harsh environment. Multi-language support Operator panel features Operator/display functions Displays paralleling breaker status Provides direct control of the paralleling breaker 320 x 240 pixels graphic LED backlight LCD Auto, manual, start, stop, fault reset and lamp test/panel lamp switches Alpha-numeric display with pushbuttons LED lamps indicating genset running, remote start, not in auto, common shutdown, common warning, manual run mode, auto mode and stop Paralleling control functions First Start Sensor TM system selects first genset to close to bus Phase lock loop synchronizer with voltage matching Sync check relay Isochronous kw and kvar load sharing Load govern control for utility paralleling Extended paralleling (baseload/peak shave) mode Digital power transfer control, for use with a breaker pair to provide open transition, closed transition, ramping closed transition, peaking and base load functions Other control features 150 watt anti-condensation heater DC distribution panel AC auxiliary distribution panel Alternator data Line-to-Neutral and Line-to-Line AC volts 3-phase AC current Frequency kw, kvar, power factor kva (three phase and total) Winding temperature Bearing temperature Engine data DC voltage Engine speed Lube oil pressure and temperature Coolant temperature Comprehensive FAE data (where applicable) Other data Genset model data Start attempts, starts, running hours, kw hours Load profile (operating hours at % load in 5% increments) Fault history Data logging and fault simulation (requires InPower) Air cleaner restriction indication Exhaust temperature in each cylinder Standard control functions Digital governing Integrated digital electronic isochronous governor Temperature dynamic governing Digital voltage regulation Integrated digital electronic voltage regulator 3-phase, 4-wire Line-to-Line sensing Configurable torque matching

Standard control functions (continued) AmpSentry AC protection AmpSentry protective relay Over current and short circuit shutdown Over current warning Single and three phase fault regulation Over and under voltage shutdown Over and under frequency shutdown Overload warning with alarm contact Reverse power and reverse Var shutdown Field overload shutdown Engine protection Battery voltage monitoring, protection and testing Overspeed shutdown Low oil pressure warning and shutdown High coolant temperature warning and shutdown Low coolant level warning or shutdown Low coolant temperature warning Fail to start (overcrank) shutdown Fail to crank shutdown Cranking lockout Sensor failure indication Low fuel level warning or shutdown Fuel-in-rupture-basin warning or shutdown Full authority electronic engine protection Control functions Time delay start and cool down Real time clock for fault and event time stamping Exerciser clock and time of day start/stop Data logging Cycle cranking Load shed Configurable inputs and outputs (20) Remote emergency stop Do not use for installation design This outline drawing is for reference only. See PowerSuite library for specific model outline drawing number. Model Dim A * Dim B * Dim C * Set weight* dry kg (lbs) Set weight* wet kg (lbs) C3000 D6e 7902 (311) 3028 (119) 3663 (144) 29526 (65092) 31194 (68771) C3250 D6e 7902 (311) 3028 (119) 3663 (144) 29526 (65092) 31194 (68771) C3500 D6e 7902 (311) 3028 (119) 3663 (144) 29526 (65092) 31194 (68771) * Weights and dimensions represent a set with standard features and alternator frame P80X. See outline drawing for weights and dimensions of other configurations.

Codes and standards Codes may not be available with all model configurations consult factory for availability. This generator set is designed in facilities certified to ISO 9001 and manufactured in facilities certified to ISO 9001 or ISO 9002. The Prototype Test Support (PTS) program verifies the performance integrity of the generator set design. Cummins products bearing the PTS symbol meet the prototype test requirements of NFPA 110 for Level 1 systems. All models are CSA certified to product class 4215-01. U.S. EPA The generator set is available listed to UL 2200, Stationary Engine Generator Assemblies for all 60 Hz low voltage models. The PowerCommand control is Listed to UL 508 - Category NITW7 for U.S. and Canadian usage. Engine certified to Stationary Emergency U.S. EPA New Source Performance Standards, 40 CFR 60 subpart IIII Tier 2 exhaust emission levels. U.S. applications must be applied per this EPA regulation. Warning: Back feed to a utility system can cause electrocution and/or property damage. Do not connect to any building s electrical system except through an approved device or after building main switch is open. For more information contact your local Cummins distributor or visit 2017 Cummins Inc. All rights reserved. Cummins is a registered trademark of Cummins Inc. PowerCommand, AmpSentry, InPower and Our energy working for you. are trademarks of Cummins Inc. Other company, product, or service names may be trademarks or service marks of others. Specifications are subject to change without notice. NAS-5849-DC-EN (09/17)