GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Similar documents
GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Attachment to Certificate IECEx TUR X Revison 0

IECEx Certificate of Conformity Annexe

ANNEX No 1. C 17/05/2006 SGA112B TERMINAL BOX ARRANGEMENT Ex e, Ex na &Ex td V (OPTION 2)

Cast Iron Frame Motors For Zone 21 Improved Efficiency EFF2

TECHNICAL BULLETIN. Sandvik MB670 Bolter Miners

VALIADIS S.A. HELLENIC MOTORS

champion series motors

IECEx Certificate of Conformity

W22 Medium Voltage Motors TEFC - Severe Duty

11mm Slot Label S1 = 162, S2 = 170, S3 = 250, S4 = 305, S5 = 330, S6 = 410, S7 = 490, S8 = 570, S9 = 650. Maximum Power Dissipation (Watts) T** T**

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Ex m Solenoid Operator Type 0519

General Purpose Three Phase Motors TEFC (IP55) High Efficiency. Standard Features

IECEx Certificate of Conformity

IECEx Certificate of Conformity Annexe

W22 Brake Motor Three-phase Electric Motor

A6C A5C-B6C B5C B5H A6C A5C B6C B5C B5H. Model. Up to kw. Power. Up to V. Voltages. Model IP55. Frame Pole 2, 4, 6, 8 and 10

MINING ELECTRIC MOTORS 3KTCR, 4KTCR, 5KTCR

AESV / AESU / AESV-LA Series Squirrel Cage Induction Motor AESV1S / AESU1S / AESV1S-LA (IE1) STANDARD EFFICIENCY

Zone 1 Linear Range - Installation Guide

Explosion proof electric motor For Fuel dispensing application. Main characteristic

TBKS/CBKS Stainless Steel Sloping Roof Keyed Terminal Box Zones 1&2, 21&22

HAIE2 -Efficiency and reliability for industry

INTER PLANT STANDARD STEEL INDUSTRY. Corresponding IS does not exist

Dimensions shown apply to both Stainless Steel and Mild Steel S1, SF*1 = 162, S2, SF*2, S2L, SF*2L = 170, S3, SF*3 = 250,

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

INSTRUCTION MANUAL (ATEX / IECEx)

MINING ELECTRIC MOTORS 3KTCR AND 4KTCR

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13

Terminal Boxes TNCN. Explosion protection Marking

Energy Saving Three Phase Motors

Brake Motors Aluminium Frame Improved Efficiency EFF2

INDEX NEMA PREMIUM EFFICIENCY

SECTION MOTOR REQUIREMENTS for HVAC

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

5 Year Warranty Premium Efficiency, TEFC Enclosure Inverter Duty Motors Corona Resistant Magnet Wire CSA Certified, UL, CE NEMA MG1 (2003) Part 31,

Operating Instructions

Floodlight Range Installation Guide

HIGH VOLTAGE TEF 1060 HV ENCLOSURE WITH A-BLOCK SOLUTIONS USER MANUAL

W22 NEMA Brake Motors - NEMA Premium

BFG range BFGC range BFN range

BFG range BFGC range BFN range

IECEx Certificate of Conformity

IECEx Certificate of Conformity

TRaC Global Limited, Unit 1, Pendle Place, Skelmersdale, West Lancashire, WN8 9PN, United Kingdom

AEEB AEVB LOW VOLTAGE SERIES Three-Phase Squirrel Cage Induction Motor Conforming to SS530 (Occasional Use) Conforming to IE1

INSTRUCTION MANUAL (ATEX / IECEx)

Aluminium Frame Motors Improved Efficiency EFF2

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Design Data 3.2 Standard Accessories 3.3 Tolerances

NEMA explosion-proof AC motors. Individual solutions are our standard

0CV2. 0CV2 series dust explosion-proof three-phase. asynchronous motor INSTRUCTIONS. Siemens Standard Motors Ltd

IECEx Certificate of Conformity

Teepak Totally Enclosed Tube Ventilated High Voltage Induction Motors. A Regal Brand.

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Hazardous Area Electrical Equipment. TBKF/CBKF Stainless Steel Flat Roof Keyed Terminal Box Zones 1&2, 21&22. Index

IECEx Certificate of Conformity

A good connection. International approvals.

SPECIFICATIONS - DETAILED PROVISIONS Section Vertical Hollowshaft Electric Motors C O N T E N T S

SEWPCC UPGRADING/EXPANSION PROJECT BID OPPORTUNITY SECTION LOW-VOLTAGE AC INDUCTION MOTORS

SERVICE AND EXPLOITATION INSTRUCTION MANUAL

W21 HIGH EFFICIENCY GENERAL PURPOSE MOTORS

TECHNICAL REQUIREMENTS FOR ELECTRICAL EQUIPMENT

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Technical Data 3.2 Standard Accessories 3.3 Tolerances

Products & Services EQ Series AC Drives. TEAMMaster WOUND ROTOR MOTORS WORLD SERIES SYNCHRONOUS MOTORS. EXPLOSION PROOF (Division 1, Zone 1)

Series E4F E5F

IECEx Certificate of Conformity

ODP SERIES PREMIUM INDUSTRIAL OPEN DRIP PROOF MOTORS C280M to C355LB Frame. Australian Version October 2013

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

xplosion Proof Motors hoyermotors.com Explosion Proof

SINGLE PHASE TEFC CAGE MOTORS

AESV / AESU / AESV-LA Series Squirrel Cage Induction Motor AESV1S / AESU1S / AESV1S-LA (IE1) STANDARD EFFICIENCY

10 Load and Motor Switchgear

ILED Aquarius Illuminated Windsock. User Manual

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Control and Terminal Box Type A21-**-*****

Motors and drives for applications in explosive atmospheres

Technical Data. Dimensions

NEMA Premium Efficiency T-Frame Motors. Three-Phase, TEFC Enclosures RELIABILITY MATTERS

Premium Efficiency Exceeds Effciency Levels Mandated by CSA C390 and EPACT 92

Operating Instructions

Clarius EP PLUS LED FLOODLIGHT Installation Guide

Design specifications

MVSI. Technical features

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

2000 Series Flameproof Xenon and Fluorescent Beacons Installation and Service Instructions

Explosion and flame-proof cast iron electric motors

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Ordering information. When placing an order, specify motor type, size and product code according to the following example.

Ex e, ia Junction boxes TNCN. Features

ToughPIX 2300XP Series INSTRUCTIONS FOR SAFE OPERATION

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

Plug and Socket Devices SolConeX 16 A Series 8570

MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS

Protection against mechanical impacts IK 08 according to IEC 68, EN Insulation class Class F (155 C), class H (180 C) on request.

ILED Dorado. User Manual

EX-REPAIR AND MAINTENANCE RECEPTACLES

Transcription:

Reg No: 1999/027771/07 (Pty) Ltd 7 Spanner Rd / PO Box 467 Olifantsfontein 1665 Tel: +27 (11) 316 4601 Fax: +27 (11) 316 5670 E-mail: admin-mgr@explolabs.co.za GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS Ex Type Examination Certificate IA CERTIFICATE Date Issued: 16 Aug 2017 *Expiry date: 16 Aug 2020 Page 1 of 5 Issue: 0 Certificate Number: S-XPL/17.1175 X Equipment: The W21 Range of Small Induction Motors Model / Type: Sizes 63 to 355 Applicant: Zest WEG Electric (Pty) Ltd PRIVATE BAG X 10011 SANDTON 2146 Manufacturer: WEG Equipamentos Eletricos S.A Serial No: All serial numbers imported between issued- and expire date and all serial numbers covered by a valid report or acceptable product certification mark. Supplied by Zest WEG Electric (Pty) Ltd Identified by Inspection Authority number S-XPL/17.1175 X And as described in the Explolabs file number XPL/18786/17.1175 is hereby certified "Explosion Protected Ex na IIC T3 Gc, Ex tc IIIB T125 C Dc IP (see original schedule), Ex tb III C T125 C Db IP6X (see schedule) Tamb (See description)", having been examined and inspected in accordance with the relevant requirements of South African Standards. SANS 60079-0: 2012 Ed 5 IEC 60079-0: 2011 Ed 6 SANS 60079-15: 2010 Ed 4 IEC 60079-15: 2010 Ed 4 SANS 60079-31: 2014 Ed 2 IEC 60079-31: 2013 Ed 2 Explosive atmospheres Part 0: Equipment General requirements Explosive atmospheres Part 15: Equipment protection by type of protection n Explosive atmospheres Part 31: Equipment dust ignition protection by enclosure "t" Risk of ignition provided: Protection afforded Equipment Protection Level (EPL) Group Performance of protection Conditions of operation T class or Max Surface Temp ( C) High Db Group III Suitable for normal operation and frequently occurring disturbances or equipment where faults are normally taken into account functioning in zones 21 and 22 T125ºC Enhanced Gc Group II Suitable for normal operation functioning in zone 2 T3 (200 C) This

ANNEX TO CERTIFICATE NO S-XPL/17.1175 X PAGE 2 OF 5 Enhanced Dc Group III Suitable for normal operation functioning in zone 22 T125ºC 1. GENERAL The W21 Range of Small Induction Motors has shaft centre heights ranging from 63 to 355mm (and NEMA equivalent) and comprises cast iron or aluminium frames for horizontal or vertical, foot and/or flange mounting. The flanges may be oversize or undersize as required and the shell provides a degree of protection of at least IP55 for equipment Group II and IP65 for equipment Group III applications. The range covers 2 to 10 pole 3 phase windings for 50 or 60Hz and is designed for connection to supplies up to 1000V and upto 1100V for Dust only applications. Two speed motors are also included in the range. Bearing Arrangements Spigots are machined at either end of the stator frame onto which the machined spigot housings of cast iron end frames are fitted. The end shields carry the bearing arrangements which are ball, angular contact or roller bearings and may be grease or oil lubricated. Optional bearing insulation is available and the bearing housings may be cast or fabricated. Stator The stator core packs are built from insulated steel laminations which are clamped together. The wound and impregnated stator assembly is secured in the stator frame by an interference fit. Rotor The rotor core packs which are built from insulated steel laminations are interference fit onto the steel shaft. The rotor cage is die-cast aluminium and balancing of the rotor is achieved by fixing washers to cast studs on the aluminium rotors. Double shaft extensions are included in the range. The construction of the rotor is assessed against Table 6 of IEC 60079-15:2010 and appropriate action taken if the results dictate it is required. Terminal Arrangement The motors are fitted with separate bolt-on cast iron terminal boxes fitted with bolt-on covers incorporating a gasket which is glued to one surface. Main terminal boxes contain cast polyester resin/fibre glass insulator blocks incorporating steel terminal studs, earthing terminals and optionally auxiliary terminals. Auxiliary terminal boxes contain IECEx component certified terminals. Details of which are shown below: Manufacturer Type Certificate Number Certificate Number BARTEC 07-9702-0*2*/**** IECEx PTB IECEx PTB 07.0007U 07.0007U WEG K1M5, K1M6, K1M8, K1M10, K1M12, K1M16 Another national or regional Ex conformity assessment Scheme. WA 12/PA66, WB 12/PA66 (160V), WB 12/PA66 (500V) Another national or regional Ex conformity assessment Scheme. The WEG ATEX only component certified terminals have been accepted in accordance with IECEx Operational Document OD009 Clause A.2.2 as detailed in the report GB/BAS/ExTR10.0072/00. Optionally the auxiliary terminal box may be integrally cast with the main terminal box or be a bolt-on addition to the main terminal box. Any size of terminal box can be fitted to any of the frame sizes within the range as long as they are suitable rated for their intended use and it is physically possible to do so.

ANNEX TO CERTIFICATE NO S-XPL/17.1175 X PAGE 3 OF 5 Ventilation Various methods of cooling are used including TEBC, TEFC, TEAO or TENV. For TEBC versions a separately IECEx certified blower motor is utilised and optionally an IECEx certified encoder may be attached to the main motor shaft. External fans when used are manufactured from polypropylene, cast iron, bronze or aluminium containing less than 6% magnesium. Windings The low voltage motors are wound using polyester-imide enamel wire with the overhangs suitably insulated and tied with string in order to compact them and keep the insulation between phases in place. Use of Variable Voltage Variable Frequency Drives The W21 range of small motors may be operated with frequency inverters (variable speed drives) in the following conditions: - For a motor to operate with the restriction of optimal flux the motor has to be IE2 High Efficiency rated or higher and the motor is to be supplier by a WEG inverter (Type CFW09 version 2.40 or higher, or the CFW11) and be de-rated according to WEG's de-rating curve. - Use of WEG PWM inverters (variable speed drives) or equivalent brand with carrier frequency from 2000 Hz up to 20000 Hz, with a frequency range up to 100 Hz or in accordance with manufacturer's recommendations. - When motors are operated below 50 Hz with contact torque loads, a de-rating factor as per WEG's de-rating Curve for Motors fed by Inverters shall be applied. - Motors shall be fitted with thermal protective devices which shall be connected into the motor control circuit in order to maintain the T3 temperature class. Auxiliaries The auxiliaries which may be fitted to this range of machine are:- - Anti-condensation heaters. - Winding and bearing temperature detectors comprising RTD's, thermocouples, thermistors or thermostats. - Vibration monitoring sensors. Ambient Temperatures The standard temperature range of the motors is -20 C to + 0 C. By the choice of suitable materials and use of the de-rating data called up on the drawings an ambient range of -55 C to 80 C may be achieved. Individual motors must be marked according to the build of the unit. Ingress Protection Rating The ingress protection rating of the motors depend on the shaft seal used: Shaft seal IP rating Lip or V ring Oil Taconite labyrinth IP55 and IP65 Labyrinth (W3) IP55 to IP66 W Seal Inproseal Shaft seal IP rating Lip or V ring IP55 Oil IP55 and IP56 and 2. INSTALLATION INSTRUCTIONS It is the manufacturer s responsibility to supply installation instructions with each unit offered for sale as required by IEC/SANS 60079-0 Clause 30.

ANNEX TO CERTIFICATE NO S-XPL/17.1175 X PAGE 4 OF 5 3. SPECIAL CONDITIONS FOR SAFE USE (denoted by X after certificate number) 1. The T3 surface temperature classification does not include motor starting or covers under duty cycle conditions. 2. The installer must ensure that any equipment certified cable glands and stopping plugs fitted to the terminal boxes are suitably IECEx/ATEX approved. Any unused cable entries must be fitted with IECEx/ATEX certified stopping plugs. When installed the cable gland or stopping plug must maintain the marked IP rating of the enclosure. 3. All terminal nuts and screws, whether used or not, shall be correctly tightened. 4. When tightening supply connections care should be taken to maintain clearance distances. 5. On auxiliary terminals the conductor insulation shall extend to within 1mm of the terminal throat. 6. There shall be no loose conductor strands on any terminal. 7. The stator RTDs and thermistors must be connected as simple apparatus into intrinsically safe circuits. 8. Anti-condensation heaters shall not be energised when the machine is energised. 9. Where auxiliary apparatus is fitted that is not covered by this certificate the installer and/or user, as appropriate, must ensure that it is suitable for the conditions of use and that it does not invalidate this certification. 10. Motors certified for dust only environments will have no restriction on the supply connections to any internal RTDs or thermistors. Based on the following documentation: IECEx BAS 10.0045X. 4. CONDITIONS OF CERTIFICATION All production units must be covered by a QAN (Quality Assurance Notification), Product Mark Scheme or batch evaluation. 5. MARKING The following (or similar) information have to be clearly and permanently marked on all units: Supplier : Zest WEG Electric (Pty) Ltd Manufacturer : WEG Equipamentos Eletricos S.A Equipment : The W21 Range of Small Induction Motors Model/Type : Sizes 63 to 355 Serial No. : --- Ex Rating : Ex na IIC T3 Gc, Ex tc IIIB T125 C Dc IP (see original schedule), Ex tb III C T125 C Db IP6X (see schedule) Tamb (See description) IA Certificate No : S-XPL/17.1175 X This certification indicates compliance with R10.1 of the Mines Health and Safety Act and/or EMR 9(2) of the Occupational Health and Safety Act, provided that the apparatus is used as relevant in accordance with: i) SANS 10086 and IEC/SANS 61241-14 requirements as applicable; ii) Any conditions mentioned in the above report; iii) Any relevant requirements and codes of practice enforced in terms of the Mine Health and Safety Act or Occupational Health and Safety Act; and iv) Any restrictions and conditions enforced by the Chief Inspector of Mines or the Principal Inspector or the Chief Inspector: Occupational Health and Safety. v) A revision certificate replaces all previous version of the certificate. vi) vii) * - Only covers equipment Imported between the Issued and Expire dates. If and when your QAN (Quality Assurance Notification) Certificate for your equipment manufacturer expires during the valid period of the IA Certification (issued for your equipment) and a new certificate is not submitted the existing IA Certification will then be cancelled. It is thus the client s responsibility to always submit the updated and valid QAN certificate(s) to Explolabs (Pty) Ltd.

ANNEX TO CERTIFICATE NO S-XPL/17.1175 X PAGE 5 OF 5 Responsible Testing Officer: Reviewed by: D Maree Senior Testing Officer H De Wet Testing Officer EXPLOLABS EXPLOSION PREVENTION SERVICES This report/certificate shall not be reproduced except in full without the written approval of the company Explolabs (Pty) Ltd shall not be liable for any losses or damages sustained on account of any failure or omission to properly perform our duties in terms of any contract undertaken by us. This disclaimer is immutable and automatically incorporated in any contract undertaken by us; notwithstanding anything to the contrary, save for the express written waiver of our managing director. By marking the equipment in accordance with the documentation/standard, the manufacturer attests on his own responsibility that the equipment has been constructed in accordance with the applicable requirements of the relevant standards and that the routine verifications and tests have been successfully completed and that the product complies with the documentation and standard(s). The contents of electronic reports/certificates cannot be guaranteed. Original certification documents will be kept on file at Explolabs (Pty) Ltd