Monitor Chlorine in Crude at Sub-ppm Levels

Similar documents
X-ray Essentials from XOS Proven Performance

better analysis counts

Elemental Analysis Advanced

Are You Prepared For Tier 3 Gasoline Standards? Presented by: Shaun Spiro and Leslie Johnson

Determination of chlorine/chlorides using MWD- XRF

ASTM D7039. Sulfur analysis plus a further 21 elements by MWDXRF. Model SS1000-S Sulfur in oil, petrol, diesel All liquids The new S1000 series MWDXRF

TSHR 6000 series TN/TS/TX analyzer

breakthrough versatility

ElvaX Sulfur in Oil analyzer

TSHR 7000 series TN-TS-TX analyzer

MESA-7220 Multi-Element Analyzer Using EDXRF Technology

MESA-7220 Measurement of Sulfur, Chlorine and other elements in Petroleum Products Using Mono-chromatic, Polarized EDXRF Analysis

Low cost EDXRF elemental analyzer

Sulfur in Oil Analyzer

Understanding the Si licon Issue

Analysis of Petroleum Samples Using the Teledyne Leeman Labs

On-Line Process Analyzers: Potential Uses and Applications

Prodigy ICP Application Note: # 1039

SPECTRO XRF Report. SPECTRO iq II

On-Line NIR Analysis for Blending

Results Certified by Core Labs for Conoco Canada Ltd. Executive summary. Introduction

EDXRF APPLICATION NOTE SULFUR IN BUNKER FUEL # 1230

A Comparison of Boat Introduction and Direct Injection using the Thermo Scientific ipro 5000 Series Combustion Analyzer

Co-Processing of Green Crude in Existing Petroleum Refineries. Algae Biomass Summit 1 October

THE OIL & GAS SUPPLY CHAIN: FROM THE GROUND TO THE PUMP ON REFINING

Simulated Distillation Analyzers, Software, Standards, Consumables, Training

S-PRO 3200 GC System for Sulfur Analysis

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER

X-ray Analysis in Petrochemical and Polymer Industries: Challenges and Solutions

1) Analysis of Ultra Low Sulfur in Automotive Fuels According to ASTM D by Sulfur Analyzer Micro-Z ULS (Rigaku Application Note XRF1053)

White Paper.

PORLA Heavy and Crude Oil Stability and Compatibility Analyzer as a Tool to Improve Profitability of Oil Industry

UOP UNITY Hydrotreating Products

ASTM D Test to Low ppb. Contact us today for a copy of the Southwest Research Institute D-5453 Fitness for Use Report.

Crude Distillation Chapter 4

WEBINAR: WDXRF for Petrochemical Analysis More Than a One-Trick Pony. October 31,

Advanced Petrochemical Applications With ICP-OES. Tina Harville, Ph.D. Application Engineer

Quantification and Characterization of Sulfur in Low-Sulfur Reformulated Gasolines by GC-ICP-MS Application

Minimizing Transmix With FuellCheck

On-Line NIR Analysis of Crude Distillation Unit

Technical Offer. Antek Model 6200 Analyzer Determine Total Sulfur and Total Nitrogen in a single analyzer

Refinery Gas. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Challenges and Opportunities in Managing CO 2 in Petroleum Refining

White Paper. Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Introduction. Background Information

Practical Applications of Compact High-Resolution 60 MHz Permanent Magnet NMR Systems for Reaction Monitoring and Online Process Control

Jet Fuel Conductivity Analysers & Additive Management systems

Achieving Ultra-Low Sulfur Diesel with IsoTherming Technology

Antek Gas Chromatography Products: A Guided Tour Through Industry

Dual Plasma Sulfur and Nitrogen Chemiluminescence Detectors. Unsurpassed Stability, Selectivity, and Sensitivity for your GC Analysis

The Analysis of Biodiesel for Inorganic Contaminants, including Sulfur, by ICP-OES

Characterization of crude:

Thermo Scientific TITAN 4000 Total Nitrogen/Sulfur/ Chlorine Analyzer

Remote Process Analysis for Process Analysis and Optimization

ISO 8754 INTERNATIONAL STANDARD. Petroleum products Determination of sulfur content Energy-dispersive X-ray fluorescence spectrometry

IROX 2000 IROX DIESEL

APC Implementation Case Study Vacuum Gasoil Cloud Point Model Predictive Controller 1

AT734G: A Combined Silicon and Arsenic Guard Catalyst

VHG Labs, Inc. Standards and Supplies for Spectrochemical Oil Analysis

Jagdish Rachh, TSC EMEA, 4 th October UniSim Design New Refining Reactors Deep Dive

TIER 3 MOTOR VEHICLE FUEL STANDARDS FOR DENATURED FUEL ETHANOL

New Small Spectrometer Concepts Covering the Ultraviolet to the Mid-Infrared

Oil & Gas. From exploration to distribution. Week 3 V19 Refining Processes (Part 1) Jean-Luc Monsavoir. W3V19 - Refining Processes1 p.

A new simple and robust process FT-NIR Spectrometer with small footprint and extended maintenance interval

Certificate of Accreditation

Refinery Support from the R&D Laboratory Perspective using Fast & Micro Gas Chromatography

2014 Software Global Client Conference

CERTIFICATE OF ACCREDITATION

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector

The Analysis of Biodiesel for Trace Metals and the Development of Certified Biodiesel Standards

Petroleum Refining Fourth Year Dr.Aysar T. Jarullah

TYPES OF BLENDING PROCESS

Selected Answers to the 2010 NPRA Q&A Hydroprocessing Questions

HOW OIL REFINERIES WORK

HOW OIL REFINERIES WORK

832 Series: Sulfur/Carbon Analysis by Combustion

Petroleum Refining Fourth Year Dr.Aysar T. Jarullah

Analysis of biodiesel oil (as per ASTM D6751 & EN 14214) using the Agilent 5100 SVDV ICP-OES

SULFIDING SOLUTIONS. Why Sulfide?

Unity TM Hydroprocessing Catalysts

Elemental Analysis of Biofuels with SPECTRO XRF and ICP Spectrometers

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

HOW OIL REFINERIES WORK

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

Analysis of Sulfur and Trace Element Content in FAME

OIL REFINERY PROCESSES

Article: Sulfur Testing VPS Quality Approach By Dr Sunil Kumar Laboratory Manager Fujairah, UAE

MB3600-HP10 Laboratory FT-NIR analyzer for hydrocarbon applications Pre-calibrated for blended gasoline, diesel, reformate and naphtha

Consulting and Training Services Available to the Petroleum Industry

ABB MEASUREMENT & ANALYTICS ANALYTICAL MEASUREMENT. PGC1000 Meeting the needs of NGL plants

This presentation focuses on Biodiesel, scientifically called FAME (Fatty Acid Methyl Ester); a fuel different in either perspective.

SCOPE OF ACCREDITATION

TechnipFMC RFCC Technology converts bunker fuels into high value products for African refiners

ISO INTERNATIONAL STANDARD

Crude Evaluation Best Practices

Optidew Vision Optical Dew-Point Meter

Hydrocracking of atmospheric distillable residue of Mongolian oil

D-2 Incorporated. JF-1A-RC RampCheck Product Brochure. Part Number: JF-1A-RC Revision Date: 09/11/15 Drawing Number: R6

Optimizing Distillate Yields and Product Qualities. Srini Srivatsan, Director - Coking Technology

The Advantage of Real Atmospheric Distillation using D7345 Test Method. Presented by Jonathan Cole, PAC

Conversion of Peanut Oil into Jet and Diesel Fuels. Panama City, Florida 22 July 2016 Edward N. Coppola

Transcription:

better analysis counts Monitor Chlorine in Crude at Sub-ppm Levels Benchtop and Online Analysis Solutions

Total Chlorine Analysis in Liquid Hydrocarbons Clora is a compact analyzer to measure total chlorine in liquid hydrocarbons such as aromatics, distillates, heavy fuels, crude oils, and aqueous solutions. Clora delivers unprecedented accuracy and precision for petroleum and petrochemical applications where ease-of-use, reliability and measurement speed are critical. Total chlorine analysis from aqueous solutions and aromatic products to heavy fuels, crudes, and catalyst For refineries, petrochemical and additive plants, pipeline terminals, and test laboratories Features and Benefits LOD: 0.13 ppm for hydrocarbons LOD: 0.3 ppm for aqueous samples Dynamic Range: 0.13 ppm to 3000 ppm Fits on any lab bench Easy to use - Intuitive touch screen - Just plug-in and measure - Measurement time: 30-900 s Extremely low maintenance: no conversion gasses, heating elements, columns, or quartz tubing LIMS data output compatible software Extended Range (XR): 0.13 ppm to 4 wt% Catalyst testing capability Accu-flow* 8-cell Autosampler* Accucell Sample Basket Available *Accu-flow and Autosampler options cannot be combined. ASTM D7536 and D4929 Get Accu-flow to Eliminate Particle Settling The optional Accu-flow design allows the sample to flow continuously during the measurement. This continuous flow eliminates the settling of chlorine, producing accurate and precise total chlorine results.

Twice the Precision, Twice the Performance Clora 2XP is designed for use with liquid hydrocarbons such as aromatics, distillates, heavy fuels and crude oils, as well as aqueous solutions. The enhanced precision of Clora 2XP is ideal for testing related to catalyst poisoning in reformers or for sites with fluid catalytic crackers and hydrocrackers monitoring very low levels of chlorine. Total chlorine analysis from aqueous solutions and aromatic products to heavy fuels and crudes For refineries, petrochemical and additive plants, pipeline terminals and test laboratories Features and Benefits LOD: 0.07 ppm in 600 s Dynamic Range: 0.07 ppm - 2 wt% Automatic sulfur correction Fits on any lab bench Easy to use - Intuitive touch screen - Just plug-in and measure - Measurement time: 30-900 s Extremely low maintenance: no conversion gasses, heating elements, columns, acids, or quartz tubing Replaceable air-cooled X-ray tube LIMS data output compatible software ASTM D7536 and D4929 Automatic Sulfur Correction Many heavy samples, like crude oil, VGO or coker residual, may have percent-level sulfur present while chlorine may be as low as a few parts per million. High sulfur levels will typically depress the chlorine measurement result during XRF analysis. Clora 2XP is able to measure the chlorine and sulfur concentrations simultaneously, and the sulfur counts information is then used to automatically correct the chlorine measurement.

TWO critical measurements, ONE push of a button, ZERO hassle Sindie +Cl is a two-in-one instrument enabling trace analysis of both sulfur and chlorine with one push of a button. It is the ideal solution to certify sulfur levels in finished products, assess chlorine for corrosion mitigation, and optimize process parameters. Total sulfur analysis from ultra low sulfur fuels to crudes Total chlorine analysis from aqueous solutions and aromatic products to heavy fuels, crudes, and catalyst For use in refinery labs, pipeline terminals, additive plants and inspection laboratories Features and Benefits Sulfur - LOD: 0.4 ppm at 300 s - Dynamic Range: 0.4 ppm to 5 wt% Chlorine - LOD: 0.3 ppm at 300 s - Dynamic Range: 0.3 ppm to 3000 ppm Extremely low maintenance: no conversion gasses, heating elements, columns, or quartz tubing Automatic sulfur correction for chlorine Easy to use - Intuitive touch screen - Just plug-in and measure - Measurement time: 30-900 s Fits on any lab bench LIMS data output compatible software ASTM D2622, D7039, D7536, D4929, SH / T 0842 Two Critical Measurements Sindie +Cl performs trace analysis of both sulfur and chlorine with one push of a button. You can measure both elements in one sample, or measure each separately by simply inserting a new sample.

Online Chlorine Analysis in Liquid Hydrocarbon Process Streams Chlorine contributes significantly to the corrosion of plant equipment and must be treated accordingly. With ever-changing crude quality and potential for process upsets, chlorine levels can shift quickly, making real-time analytical results invaluable. Powered by MWDXRF, Clora Online uses ASTM D7536 technology and delivers real-time, continuous analysis of total chlorine from 0.2 ppmw up to 3000 ppmw. By monitoring desalted crude, a plant can optimize performance and immediately see impacts of crude changes (including organic chloride). This process analyzer is ATEX and NEC certified for hazardous area locations. Upstream desalting, refining, power generation and effluent management Total chlorine analysis in: - raw and desalted crudes - water and effluent streams - refinery process streams - finished product ONLINE Features Uses ASTM D7536 technology ATEX Zone 1 and NEC Cl Div 2 Certified LOD: 0.2 ppmw in hydrocarbon matrices @ 300 s LOD: 0.6 ppmw in aqueous streams @ 300 s Dynamic range: 0.2 ppmw 3000 ppmw Calibration is linear up to 3000 ppmw and one calibration curve runs all hydrocarbon matrices Robust industrial design: wall mounted or stand alone Benefits Continuous, real-time analysis Rapid response to upsets Easy to use with intuitive touch screen interface Direct measurement in ppm wt Low Maintenance: no consumable liquids, gasses, combustion, or sample conversion Not sensitive to sample temperature changes Multi-stream analysis capability Auto-validation capability ATEX and NEC Certified

Benchtop and Online Chlorine Analysis Monitoring chlorine for corrosion mitigation is critical during refining processes. Chlorine can poison expensive catalysts and lead to corrosion in overhead or reactor effluent systems. Clora analyzers offer breakthrough analytical solutions for the determination of chlorine in liquid hydrocarbon samples such as aromatics, distillates and heavy fuels, and aqueous solutions. Advanced Analysis with MWDXRF Monochromatic Wavelength Dispersive X-ray Fluorescence (MWDXRF) utilizes state-of-the-art focusing and monochromating optics to increase excitation intensity and dramatically improve signal-to-background ratio compared to traditional WDXRF instruments. This enables significantly improved detection limits, precision, and a reduced sensitivity to matrix effects. A monochromatic and focused primary beam excites the sample and secondary characteristic fluorescence X-rays are emitted from the sample. A second monochromating optic selects the chlorine characteristic X-rays and directs these X-rays to the detector. MWDXRF is a direct measurement technique and does not require consumable gasses or sample conversion delivering robust and low-maintenance analyzers with dramatically lower detection limits and faster response times. POLYCHROMATIC X-RAYS FROM SOURCE SAMPLE MONOCHROMATIC EXCITATION X-RAYS FROM SAMPLE OPTIC 1 OPTIC 2 DETECTOR SELECTED MONOCHROMATIC SAMPLE X-RAYS Eliminate Particle Settling with Accu-flow Accu-flow technology helps to minimize the effects of particulate settling, which is common when testing for chlorides in crude oil using XRF in the laboratory. Over a typical measurement cycle, the heavier particles can settle to the bottom of the sample cup and cause higher than normal results. Accu-flow pushes the sample through the system keeping the sample uniform, delivering a result that better reflects crude streams as they exist in the refinery. Accu-flow is available with Clora benchtop analyzers. 15 Tech Valley Drive East Greenbush, New York 12061 USA PH 518.880.1500 FAX 518.880.1510 info@xos.com www.xos.com XOS all rights reserved. Clora, Clora 2XP, Clora Online and Sindie +Cl are registered trademarks of XOS.