General catalogue incl. replacement lists

Similar documents
Circulation pumps. Wet rotor circulators and accessories. Heating Drinking water Solar Geothermy Condensate

3 Specification Magneta Smedegaard

Lenntech. Calio S. Type Series Booklet. High-efficiency Circulator Pump. Tel Fax.

4 Specification Magneta Smedegaard twin pumps

real quality made in italy circulation pumps

RE, RED. Electronically Controlled Inverter Driven Circulation Pump. Twin Execution ENERGY EFFICIENCY OF CIRCULATING PUMPS

Data sheet: Wilo-TOP-Z 50/7 (3~400 V, PN 6/10, RG)

Japanese Technology since Ego Circulators. Databook

INTELLIGENTE DRUCKLUFT MADE IN GERMANY

Data sheet: Wilo-TOP-Z 30/7 (3~400 V, PN 10, RG)

GRUNDFOS DATA BOOKLET. Grundfos UPBasic. Circulator pumps 50 Hz

Data sheet: Wilo-Stratos-Z 25/1-8

TECHNICAL DATA. ErP Ready NewMotorTechnolgy. Electronically controlled high-efficiency pumps for heating, air conditioning, cooling and sanitary water

Data sheet: Wilo-Yonos MAXO 40/0,5-16

Series description: Wilo-Stratos ECO-STG

Data sheet: Wilo-TOP-S 40/10 (1~230 V, PN 6/10)

UNIT TAG: TYPE OF SERVICE: SUBMITTED BY: APPROVED BY: ORDER NO.: MAGNA F N. Pump Data

High-efficiency Drinking Water Pump. Rio-Eco Therm N. Type Series Booklet

Series description: Wilo-Stratos

Data sheet: Wilo-TOP-S 40/4 (1~230 V, PN 6/10)

Data sheet: Wilo-TOP-Z 30/10 (1~230 V, PN 10, RG)

Circulator Pumps with Continuously Variable Differential Pressure Control and I.R. Interface for Remote Control

Company name: Created by: Phone:

TECHNICALINFO. The LEITNER Drive System

Heating, air-conditioning, cooling

ALUMINIUM GEAR UNITS WITH SMOOTH MOTORS kw

Data sheet: Wilo-Stratos-D 32/1-8

GRUNDFOS DATA BOOKLET NS, PF. 50 Hz

Data sheet: Wilo-Stratos-D 50/1-12

CMBE Booster. Lenntech. Description 50/60 Hz. Horizontal, multistage centrifugal boosters

60Hz HORIZONTAL MULTISTAGE PUMPS

Series description: Wilo-TOP-S

Series: GA6-1½, GA6-2, GA7-1¼, GA7-1½

UPS32-60 F B 1x V PN6/10

Series: GA6-1½, GA6-2, GA7-1¼, GA7-1½

Series description: Wilo-TOP-STGD

Series: EC & ED. EC & ED RPM - 60Hz. (See Indivdual curves for symbol number)

In-Line Dry Rotor Circulating Pumps. EIL R Series EIL- FK Series

Plate Heat Exchangers

SEV D. Grundfos Pump GRUNDFOS DATA BOOKLET

Series: EC & ED. EC & ED RPM - 60Hz. (See Indivdual curves for symbol number)

MBN Multistage Ring Section Pumps

Centrifugal pumps. made of Polypropylene and PVDF for transferring aggressive media like acids and alkalies

TPE /2-S-A-F-A-BAQE 3X400 50HZ

TPED /4-S-A-F-A-BAQE 3X400 50HZ

EVOPLUS / EVOPLUS SAN

Series: G5-1¼, G6-1¼ RPM - 60Hz. CAPACITIES TO 80 GPM (5 LPS) HEADS TO 135 FEET (41 M)

Data sheet: Wilo-Stratos PICO 25/1-6

MAGNA3 D F 280 1x230V PN16

Grundfos Home Booster

High efficiency pumps

UNIT TAG: TYPE OF SERVICE: SUBMITTED BY: APPROVED BY: ORDER NO.: CME3-7 A-S-I-E-AVBE. Pump Data

Butterfly valves. Introduction. Made of ductile cast iron

Data sheet: Wilo-Stratos PICO 25/

UNIT TAG: TYPE OF SERVICE: SUBMITTED BY: APPROVED BY: ORDER NO.: UP B5. Circulator pumps. Motor Data Flow: Head: Efficiency: Pump Data

Series: G5-1¼, G6-1¼ RPM - 60Hz. CAPACITIES TO 80 GPM (5 LPS) HEADS TO 135 FEET (41 M)

Customised drive solutions

MAGNA F 250 1x230V PN6/10

MAGNA F 340 1x230V PN6/10

TPE /4-A-F-A-BAQE 3X400 50HZ

TPE S-A-F-A-BUBE

Series: ES. 4ES RPM - 60Hz. ES RPM - 60Hz. (See Indivdual curves for symbol number)

MAGNA F 220 1x230V PN6/10

Company name: GRUDNFOS VisMin Created by: Kimmboy Ancis Phone: Date: 13/03/2017

ELECTRIC MULTI-TURN ACTUATORS for the automation of industrial and special valves with torque requirements up to 120,000 Nm

Position Count Description Unit price

GRUNDFOS DATA BOOKLET TP, TPD, TPE, TPED, TPE2, TPE2 D, TPE3, TPE3 D. In-line circulator pumps. 50 Hz. Lenntech

TPE 25-80/2-A-O-A-BUBE 1X230 50HZ

Your own power station: For continuous power

Data sheet: Wilo-CronoNorm-NL 150/315-37/4

MAGNA3 D x230V PN10

Lowara Ecocirc Vario (EV)

Series: ES. 4ES RPM - 60Hz. ES RPM - 60Hz. (See Indivdual curves for symbol number)

Volute Casing Centrifugal Pumps PN 16 for heat-transfer liquids Heat-transfer oil up to 350 C Hot water up to183 C

UPS F B 3x V PN6/10

Chemical Magnetic Pumps with PTFE/PFA lining ATEX- and FDA compliant

Bulletin D51 September D51 D61 D71 D91 Series. Centrifugal Pumps. Capacities to 240 GPM Heads to 360 Feet MTH PUMPS

TPE N-A-F-A-GQQE

Data sheet: Wilo-VeroTwin-DPL 65/ /2

SolarMax MT series. The power pack for maximum yields.

EVOTRON SAN WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA

NBE50-250/205 A-F2-A-BAQE

TPE N-A-F-A-GQQE

NBE40-125/139 AS-F2-A-BAQE

NK /310A2F1AE-SBAQE

Side channel pumps PN 16 SOH - SOHB - SOHM. Self-priming centrifugal pumps. Technical description

NKE80-160/175A2F2AE-SBQQE

High Pressure Centrifugal Pumps Product Overview

MAGNA x230V PN10

SE M.C.N.51D

NB80-160/161 A-F2-A-BQQE

OIL-FREE, WATER-INJECTED SCREW COMPRESSORS Volumetric flow rate: m 3 /min acfm

Data sheet: Wilo-VeroLine-IPL 100/ /4

EDISON DV VARIABLE SPEED DIRECT DRIVEN SCREW COMPRESSORS NEWTON DIRECT DRIVEN SCREW COMPRESSORS. from 45 up to 315 kw from 7.

Data sheet: Wilo-VeroTwin-DPL 40/ /4

BASCO PIPELINE AFTERCOOLERS. ...world leaders in heat transfer technology

Infinity i-star 13 Flow: 13 m3/h - 6 m.w.c. A Infinity i-star 17 Flow: 17 m3/h - 6 m.w.c. A

Davey 4 Submersible. Borehole Pumps and Motors 4 BOREHOLE PUMPS AND MOTORS. Borehole Well with Pump and Motor. Water Table. Aquifer.

oil-free, Water-InJected ScreW compressors Volumetric flow rate: m 3 /min acfm

Performance That Moves. EmCon Traction Converters

Transcription:

Circulation pumps effiziente Pumpentechnologie General catalogue 2009 incl. replacement lists

Data might be subject to alteration, errors excepted!

Content I. Product programme Product overview... 1 Type key... 8 Circulation pumps with screwed connection... 9 HEP: High efficiency pumps, electronically controlled, efficiency class A... 9 HUE: Efficiency pumps, electronically controlled, efficiency class B... 12 HUPA: Heating circulation pumps, non-controlled, pressure head 2.5-7 m... 15 HGPA: Heating circulation pumps, non-controlled, pressure head 7-12 m... 18 BUP: Circulation pumps for domestic water... 21 BGPA: Circulation pumps for domestic water, pressure head 7-12 m... 24 SUP: Circulation pumps for solar systems... 27 KUP: Circulation pumps for geothermy, air-conditioning, refrigeration... 29 KGPA: Circulation pumps for geothermy, air-conditioning, refrigeration, pressure head 7-12 m 31 HUP: Heating circulation pumps with condensation water protection... 34 Circulation pumps with flanged connection... 37 HUP/HUPD: Heating circulation pumps, non-controlled... 37 HUP/HUPD: Heating circulation pumps, electronically controlled... 43 NMT: Heating circulation pumps, electronically controlled, with ECM-technology... 46 Accessories... 49 Z: Unions... 49 Terminal plug for circulation pumps... 49 II. Replacement lists Circulation pumps with screwed connection... 50 HEP: High efficiency pumps, electronically controlled, efficiency class A... 50 HUE: Efficiency pumps, electronically controlled, efficiency class B... 50 HUPA: Heating circulation pumps, non-controlled, pressure head 2.5-7 m... 51 HGPA: Heating circulation pumps, non-controlled, pressure head 7-12 m... 51 BUP: Circulation pumps for domestic water... 52 SUP: Circulation pumps for solar systems... 53 KGPA: Circulation pumps for geothermy, air-conditioning, refrigeration, pressure head 7-12 m 53 HUP: Heating circulation pumps with condensation water protection... 54 Circulation pumps with flanged connection... 55 HUP/HUPD: Heating circulation pumps, non-controlled... 55 HUP/HUPD: Heating circulation pumps, electronically controlled... 56 NMT: Heating circulation pumps, electronically controlled, with ECM-technology... 56

Product overview High effi ciency pumps HEP electronically controlled screwed connection Product group HP HE Icon Effi ciency pumps HUE electronically controlled screwed connection Standard connection R 1/2, R 1, R 1¼ R 1/2, R 1, R 1¼ Screw thread G 1, G 1½, G 2 G 1, G 1½, G 2 Installation length 130 / 180 mm 130 / 180 mm Capacity Q max. 3.2 m³ / h 3.2 m³ / h Pressure head H max. 6 m 6 m Media temperature (ambient temperature 0 C to max. 40 C / 32 F to max. 104 F) Main areas of application +2 C... +95 C (35.6 F... 203 F) Heating, air-conditioning and industrial applications as double pipe systems, underfl oor heating, boiler and primary circuits Media handled Heating water according to VDI 2035 thin, clean, non-aggressive and non-explosive, mineral oil free liquids without solid particles or fi bres. media with a viscosity of max. 10 mm² / s. For a glycol ratio of >20%, the operating data have to be checked. Operating pressure max. 10 bar max. 10 bar Insulation class F F Enclosure class IP 42 IP 42 Motor protection stall current resistant, no additional motor protection necessary Power supply 1~230 V / 50 Hz 1~230 V / 50 Hz Pump housing grey cast iron grey cast iron Shaft ceramics ceramics Impeller composite composite +2 C... +95 C (35.6 F... 203 F) Heating, air-conditioning and industrial applications as double pipe systems, underfl oor heating, boiler and primary circuits Heating water according to VDI 2035 thin, clean, non-aggressive and non-explosive, mineral oil free liquids without solid particles or fi bres. media with a viscosity of max. 10 mm² / s. For a glycol ratio of >20%, the operating data have to be checked. stall current resistant, no additional motor protection necessary Bearing axial and radial Features Dimensions ceramics ECM-technology smooth running very low energy consumption integrated night economy feature convenient operation pre-mounted, screwable plug space-saving, axially integrated terminal box manual start-up feature types of regulation: optionally p or const. p ceramics energetically optimised smooth running low energy consumption integrated night economy feature convenient operation pre-mounted, screwable plug space-saving, axially integrated terminal box manual start-up feature types of regulation: optionally p or const. p 127.5 162.5 127.5 162.5 1

Heating circulation pumps HUPA non-controlled / 3 stages screwed connection Product group H HG Icon Heating circulation pumps HGPA non-controlled / 3 stages screwed connection Standard connection R 1/2, R 1, R 1¼ R 1, R 1¼ Screw thread G 1, G 1½, G 2 G 1½, G 2 Installation length 130 / 180 mm 180 mm Capacity Q max. 3.8 m³ / h 12.0 m³ / h Pressure head H max. 7 m 12 m Media temperature (ambient temperature 0 C to max. 40 C / 32 F to max. 104 F) Main areas of application +2 C... +110 C (35.6 F... 230 F) Heating, air-conditioning and industrial applications as single and double pipe systems, underfl oor heating, boiler and primary circuits Media handled Heating water according to VDI 2035 thin, clean, non-aggressive and non-explosive, mineral oil free liquids without solid particles or fi bres. media with a viscosity of max. 10 mm² / s. For a glycol ratio of >20%, the operating data have to be checked. Operating pressure max. 10 bar max. 10 bar Insulation class H H Enclosure class IP 44 IP 44 +2 C... +110 C (35.6 F... 230 F) Motor protection stall current resistant, integrated thermal switch no additional motor protection necessary Power supply 1~230 V / 50 Hz 1~230 V / 50 Hz Pump housing grey cast iron grey cast iron Shaft ceramics ceramics Impeller composite composite Heating, air-conditioning and industrial applications as single and double pipe systems, underfl oor heating, boiler and primary circuits Heating water according to VDI 2035 thin, clean, non-aggressive and non-explosive, mineral oil free liquids without solid particles or fi bres. media with a viscosity of max. 10 mm² / s. For a glycol ratio of >20%, the operating data have to be checked. Bearing axial and radial Features Dimensions ceramics energetically optimised manual start-up feature space-saving, axially integrated terminal box with three-stage switch for manual speed selection ceramics manual start-up feature space-saving, axially integrated terminal box with three-stage switch for manual speed selection 2

Circulation pumps BUP for domestic water non-controlled / 3 stages screwed connection Product group UB BG Icon Circulation pumps BGPA for domestic water non-controlled / 3 stages screwed connection Standard connection R 1/2, R 3/4, R 1 R 3/4, R 1 Screw thread G 1, G 1¼, G 1½ G 1¼, G 1½ Installation length 130 / 150 / 180 mm 180 mm Capacity Q max. 5.0 m³ / h 12.0 m³ / h Pressure head H max. 6 m 12 m Media temperature (ambient temperature 0 C to max. 40 C / 32 F to max. 104 F) Main areas of application Media handled +2 C... +110 C (35.6 F... 230 F) Drinking water systems in building and industrial installations for domestic, cooling and heating circuits, underfl oor heating Drinking water and heated drinking water with up to 65 C (230 F) and max. 14 dh. media with a viscosity of max. 10 mm² / s. Operating pressure max. 10 bar max. 10 bar Insulation class H H Enclosure class IP 44 IP 44 Motor protection stall current resistant, no additional motor protection necessary Power supply 1~230 V / 50 Hz 1~230 V / 50 Hz Pump housing bronze bronze Shaft ceramics ceramics Impeller composite composite +2 C... +110 C (35.6 F... 230 F) Drinking water systems in building and industrial installations for domestic, cooling and heating circuits Drinking water and heated drinking water with up to 65 C (230 F) and max. 14 dh. media with a viscosity of max. 10 mm² / s. stall current resistant, no additional motor protection necessary Bearing axial and radial Features Dimensions ceramics manual start-up feature space-saving, axially integrated terminal box resin-cast stator condensation-water free with three-stage switch for manual speed selection particularly suitable for underfl oor heating ceramics manual start-up feature axially integrated terminal box resin-cast stator condensation-water free with three-stage switch for manual speed selection BGPA 25-12.0 U 180 3

Circulation pumps SUP for solar systems non-controlled / 3 stages screwed connection Product group S K Icon Circulation pumps KUP for geothermy, air-conditioning / refrigeration non-controlled / 3 stages screwed connection Standard connection R 1/2, R 1 R 1/2, R 1 Screw thread G 1, G 1½ G 1, G 1½ Installation length 130 / 180 mm 130 / 180 mm, further types on request Capacity Q max. 5.5 m³ / h 5.5 m³ / h Pressure head H max. 6 m 6 m Media temperature (ambient temperature 0 C to max. 40 C / 32 F to max. 104 F) Main areas of application -10 C... +110 C (14 F... 230 F), short-term (< 2h) up to +130 C (266 F) Solar systems, particularly high-flow systems -25 C... +110 C (-13 F... 230 F) geothermy, air-conditioning and refrigeration Media handled Heating water according to VDI 2035 thin, clean, non-aggressive and non-explosive, mineral oil free liquids without solid particles or fibres. media with a viscosity of max. 10 mm² / s. For a glycol ratio of >50%, the operating data have to be checked. Operating pressure max. 10 bar max. 10 bar Insulation class H H Enclosure class IP 44 IP 44 Motor protection stall current resistant, no additional motor protection necessary Power supply 1~230 V / 50 Hz 1~230 V / 50 Hz thin, clean, non-aggressive and non-explosive, mineral oil free liquids without solid particles or fibres. media with a viscosity of max. 10 mm² / s. For a glycol ratio of >50%, the operating data have to be checked. stall current resistant, no additional motor protection necessary Pump housing grey cast iron, cataphoretically coated grey cast iron, cataphoretically coated Shaft ceramics ceramics Impeller composite composite Bearing axial and radial Features Dimensions ceramics large capacity for high-flow systems cataphoretically coated housing particularly durable and robust condensation-water free resin-cast stator manual start-up feature ceramics large capacity cataphoretically coated housing particularly durable and robust condensation-water free resin-cast stator resin-cast terminal box pre-mounted connection cable manual start-up feature 24

Circulation pumps KGPA for geothermy, air-conditioning / refrigeration non-controlled / 3 stages screwed connection Product group KG U Icon Heating circulation pumps HUP non-controlled / 3 stages screwed connection Standard connection R 1, R 1¼ R 1/2, R 3/4, R 1, R 1¼ Screw thread G 1½, G 2 G 1, G 1¼, G 1½, G 2 Installation length 180 mm 130 / 180 mm Capacity Q max. 12.0 m³ / h 5.0 m³ / h Pressure head H max. 12 m 6 m Media temperature -25 C... +110 C (-13 F... 230 F) -10 C... +110 C (14 F... 230 F) (ambient temperature 0 C to max. 40 C / 32 F to max. 104 F) Main areas of application geothermy, air-conditioning and refrigeration Heating, air-conditioning and industrial applications as single and double pipe systems, underfl oor heating, boiler and primary circuits Media handled thin, clean, non-aggressive and non-explosive, mineral oil free liquids without solid particles or fi bres. media with a viscosity of max. 10 mm² / s. For a glycol ratio of >50%, the operating data have to be checked. Operating pressure max. 10 bar max. 10 bar Insulation class H H Enclosure class IP 44 IP 44 Motor protection stall current resistant, no additional motor protection necessary Power supply 1~230 V / 50 Hz 1~230 V / 50 Hz Pump housing grey cast iron, cataphoretically coated grey cast iron Shaft ceramics ceramics Impeller composite composite Heating water according to VDI 2035 thin, clean, non-aggressive and non-explosive, mineral oil free liquids without solid particles or fi bres. media with a viscosity of max. 10 mm² / s. For a glycol ratio of >20%, the operating data have to be checked. stall current resistant, no additional motor protection necessary Bearing axial and radial Features Dimensions ceramics large capacity cataphoretically coated housing particularly durable and robust condensation-water free resin-cast stator pre-mounted connection cable manual start-up feature ceramics resin-cast stator condensation-water free manual start-up feature with three-stage switch for manual speed selection KGPA 25-12.0 U 180 5

Heating circulation pumps HUP / HUPD non-controlled fl anged connection Product group F FE Icon Heating circulation pumps HUP / HUPD electronically controlled fl anged connection Standard connection DN 40-80 DN 40-80 Installation length 250 / 280 / 340 / 360 mm 250 / 280 / 340 / 360 mm Capacity Q max. 70 m³ / h 65 m³ / h Pressure head H max. 11 m 10 m Media temperature (ambient temperature 0 C to max. 40 C / 32 F to max. 104 F) Main areas of application -10 C... +110 C (14 F... 230 F) Heating, air-conditioning and industrial applications as single and double pipe systems, underfl oor heating, boiler and primary circuits Media handled Heating water according to VDI 2035 thin, clean, non-aggressive and non-explosive, mineral oil free liquids without solid particles or fi bres. media with a viscosity of max. 10 mm² / s. For a glycol ratio of >20%, the operating data have to be checked. Operating pressure PN 6 PN 6 Insulation class H H Enclosure class IP 43 IP 43 Motor protection integrated thermal switch, external or internal motor protection by relay necessary Power supply 3~400 V / 50 Hz bzw. 1~230 V / 50 Hz 1~230 V / 50 Hz Pump housing grey cast iron grey cast iron Shaft stainless steel stainless steel Impeller stainless steel stainless steel -10 C... +120 C (14 F... 248 F) Heating, air-conditioning and industrial applications as single and double pipe systems, underfl oor heating, boiler and primary circuits Heating water according to VDI 2035 thin, clean, non-aggressive and non-explosive, mineral oil free liquids without solid particles or fi bres. media with a viscosity of max. 10 mm² / s. For a glycol ratio of >20%, the operating data have to be checked. integrated thermal switch, external or internal motor protection by relay necessary Bearing axial and radial Features Dimensions carbon all water contacting parts are corrosion protected high operational safety see corresponding product range carbon all water contacting parts are corrosion protected high operational safety see corresponding product range 6

Product group Heating circulation pumps NMT electronically controlled, with ECM-technology fl anged connection FE / NMT Icon Standard connection DN 40-80 Installation length Capacity Q max. Pressure head H max. 250 / 280 / 340 / 360 mm 65 m³ / h 14 m Media temperature (ambient temperature 0 C to max. 40 C / 32 F to max. 104 F) Main areas of application -10 C... +110 C (14 F... 230 F) Heating, air-conditioning and industrial applications as single and double pipe systems, underfl oor heating, boiler and primary circuits Media handled Heating water according to VDI 2035 thin, clean, non-aggressive and non-explosive, mineral oil free liquids without solid particles or fi bres. media with a viscosity of max. 10 mm² / s. For a glycol ratio of >20%, the operating data have to be checked. Operating pressure PN 6 Insulation class H Enclosure class IP 44 Motor protection Power supply Pump housing Shaft Impeller Bearing axial and radial Features Dimensions integrated thermal switch, external or internal motor protection by relay necessary 1~230 V / 50 Hz grey cast iron stainless steel stainless steel carbon quick and easy installation high effi ciency, 60% less energy consumption drive: electronically commutated, self-regulated permanent-magnet motors the pumps are delivered in a factory set standard confi guration, changes to settings via Ethernet interface (RJ-45) see corresponding product range 7

The Halm type key Type of pump Standard connection Pressure head in m water column Speed switchable or controlled Installation length in mm HUPA 25-4.0 U 180 Notes Circulation pumps with screwed connection HEP: High efficiency pump, electronically controlled HUE: Efficiency pump, electronically controlled HUPA: Heating circulation pump, pressure head up to 7m HGPA: Heating circulation pump, pressure head up to 12m BUP: Circulation pump for domestic water BGPA: Circulation pump for domestic water, pressure head up to 12m SUP: Circulation pump for solar systems KUP: Circulation pump for geothermy, air-conditioning / refrigeration KGPA: Circulation pump for geothermy, air-conditioning / refrigeration, pressure head up to 12m KGPB: Circulation pump for geothermy, air-conditioning / refrigeration, pressure head up to 12m, with bronze housing HUP: Heating circulation pump, condensation-water protected Circulation pumps with flanged connection HUP: Heating circulation pump, flanged connection HUPD: Heating circulation pump, double flange NMT: Heating circulation pump, flanged connection, with ECM-technology U: speed manually switchable E: electronically controlled speed 8

Product group HP High efficiency pumps HEP, pressure head 4 m and 6 m, energetically optimised, with screwed connection, electronically controlled, 1x230 V, installation length 130 / 180 mm Up to 70% energy saving Product innovation High efficiency pump HEP with energy efficiency class A Up to 70% energy saving through ECM-technology Featured with state-of-the-art ECM-technology, the Halm high effi - ciency pumps achieve energy effi ciency class A in both the 4m and 6m design. Thus up to 70% energy saving can be achieved, compared to conventional circulation pumps. Due to the fl exible regulation HEP are the ideal replacement pumps for new or existing systems in single- or two-family houses. They are easy to install, prevent disturbing fl ow noises and have a considerably lower energy consumption. With the turning knob on the axially integrated terminal box one can easily and conveniently adjust the control characteristics or the speed stages. Types of regulation: electronic proportional or fi xed pressure regulation with integrated night economy feature. Plug & Pump : By means of the pre-mounted, screwable plug the electrical connections can be connected in an easy, quick and safe manner. A particularly compact design facilitates installation even with little space available. 9

The benefits at a glance: energy economy to save your money Latest drive technology enables high rates of effi ciency and compliance with energy effi ciency class A for 4m and 6m designs. saving while sleeping With the integrated night economy feature (can optionally be activated) the power output is automatically reduced to the minimum characteristic. This additionally saves energy. nearly always the appropriate pump Operation with automatic speed control or fi xed speed optical control An LED on the axially integrated terminal box always keeps you informed of whether the pump is in operation. The terminal box does not need to be opened to check the voltage. This simplifi es analyses in case of faults. compact design The axially arranged terminal box enables a compact design, simple installation and convenient handling. Product features high effi ciency pump with ECM-technology compact design smooth running very low energy consumption integrated night economy feature convenient operation pre-mounted, screwable plug space-saving axially integrated terminal box manual start-up feature installation length: 130 / 180 mm standard connection: R ½ - 1¼ enclosure class: IP 42 insulation class: F media temperature: +2 C...+95 C (35.6 F... 203 F) capacity Q max.: 3.2 m³ / h pressure head H max.: 6 m types of regulation: optionally p or const. p Main areas of application Heating, air-conditioning and industrial applications as double pipe systems, underfl oor heating, boiler and primary circuits Media handled Heating water according to VDI 2035 Thin, clean, non-aggressive and non-explosive, mineral oil free liquids without solid particles or fi bres. Media with a viscosity of max. 10 mm² / s. For a glycol ratio of >20%, the operating data have to be checked. 10

Dimensions 127.5 162.5 Type overview Installation lenght [mm] 130 180 Type Standard connection Power consumption P1 [W] Nominal current [A] max. Efficiency class Item No. Weight [kg] HEP 15-4.0 E 130 R ½ 4... 24... 0.3 A 0321-34004.5 2,7 HEP 15-6.0 E 130 R ½ 4... 50... 0.46 A 0321-34006.5 2,7 HEP 25-4.0 E 130 R 1 4... 24... 0.3 A 0323-34004.5 2,7 HEP 25-6.0 E 130 R 1 4... 50... 0.46 A 0323-34006.5 2,7 HEP 25-4.0 E 180 R 1 4... 24... 0.3 A 0323-34204.5 2,7 HEP 25-6.0 E 180 R 1 4... 50... 0.46 A 0323-34206.5 2,7 HEP 30-4.0 E 180 R 1¼ 4... 24... 0.3 A 0324-34204.5 2,8 HEP 30-6.0 E 180 R 1¼ 4... 50... 0.46 A 0324-34206.5 2,8 Characteristics H [m] 4 3 2 1 0 4m 3m 2m 1m min HEP... 4.0 E 0.0 0.4 0.8 1.2 1.6 2.0 2.4 Q [m 3 /h] H [m] 6 5 4 3 2 1 0 4m 3m min HEP... 6.0 E 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 Q [m 3 /h] 2m P1 [W] HEP... 4.0 E P1 [W] HEP... 6.0 E 40 30 20 10 4m 3m 2m 1m 50 40 30 20 10 5m 4m 3m 2m 0 0.0 0.4 0.8 1.2 1.6 2.0 2.4 Q [m 3 /h] 0 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 Q [m 3 /h 11

Product group HE Efficiency pumps HUE, pressure heads of 4 m and 6 m, energetically optimised, with screwed connection, electronically controlled, 1x230 V, installation length 130 / 180 mm The budget alternative! Up to 50% energy saving The electronically controlled pump Halm HUE comes with a newly designed, optimized motor and enhanced hydraulics. With this the 4m and 6m designs the pumps comply with energy effi ciency class B. Similar to the pumps of the HEP series, also the HUE products can optionally be operated with automatic speed control (proportional pressure) or with fi xed speed. With the turning knob on the axially integrated terminal box one can easily and conveniently adjust the control characteristics or the speed stages. However, the factory setting proves suitable in most cases. Types of regulation: electronic proportional or fi xed pressure regulation with integrated night economy feature. By means of the pre-mounted, screwable plug the electrical connections can be connected in an easy, quick and fast manner. A particularly compact design facilitates installation even with little space available. The benefits at a glance: saving money through reduction of energy consumption Latest drive technology enables high rates of effi ciency and compliance with energy effi ciency class B for 4m and 6m designs. saving while sleeping With the integrated night economy feature (can optionally be activated) the power output is automatically reduced to the minimum characteristic. This additionally saves energy. nearly always the appropriate pump Operation with automatic speed control or fi xed speed optical control An LED on the axially integrated terminal box always keeps you informed of whether the pump is in operation. The terminal box does not need to be opened to check the voltage. This simplifi es analyses in case of faults. compact design The axially arranged terminal box enables a compact design, simple installation and convenient handling. 12

Type overview Installation length [mm] 130 180 Type Standard connection Power consumption P1 [W] Nominal current [A] Efficiency class Item No. Weight [kg] HUE 15-4.0 E 130 R ½ 22... 56 0,24 B 0321-33004.5 2,7 HUE 15-6.0 E 130 R ½ 27... 79 0,27 B 0321-33006.5 2,7 HUE 25-4.0 E 130 R 1 22... 56 0,24 B 0323-33004.5 2,7 HUE 25-6.0 E 130 R 1 27... 79 0,27 B 0323-33006.5 2,7 HUE 25-4.0 E 180 R 1 22... 56 0,24 B 0323-33204.5 2,7 HUE 25-6.0 E 180 R 1 27... 79 0,27 B 0323-33206.5 2,7 HUE 30-4.0 E 180 R 1¼ 22... 56 0,24 B 0324-33204.5 2,8 HUE 30-6.0 E 180 R 1¼ 27... 79 0,27 B 0324-33206.5 2,8 Characteristics H [m] 4 HUE... 4.0 E H [m] 6 5 HUE... 6.0 E 3 3m 4 4m 2 1 2m 1m 3 2 1 3m 2m 0 0.0 0.4 0.8 1.2 1.6 2.0 2.4 Q [m 3 /h] 0 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 Q [m 3 /h] P1 [W] HUE... 4.0 E P1 [W] HUE... 6.0 E 80 60 100 80 40 60 20 40 20 0 0.0 0.4 0.8 1.0 1.6 2.0 2.4 Q [m 3 /h] 0 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 Q [m 3 /h] 13

Product features energetically optimised smooth running low energy consumption integrated night economy feature convenient operation pre-mounted plug space-saving axially integrated terminal box manual start-up feature installation length: 130 / 180 mm standard connection: R ½ - 1¼ enclosure class: IP 42 insulation class: F media temperature: +2 C...+95 C (35.6 F... 203 F) capacity Q max.: 3.2 m³ / h pressure head H max.: 6 m types of regulation: optionally p or const. p Main areas of application Heating, air-conditioning and industrial applications as double pipe systems, underfl oor heating, boiler and primary circuits Media handled Heating water according to VDI 2035 Thin, clean, non-aggressive and non-explosive, mineral oil free liquids without solid particles or fi bres. Media with a viscosity of max. 10 mm² / s. For a glycol ratio of >20%, the operating data have to be checked. Dimensions 127.5 162.5 14

Product group H Heating circulation pumps HUPA pressure head up to 7 m, energetically optimised, with screwed connection, non-controlled / 3 stages, 1x230 V, installation length 130 / 180 mm The new Halm standard product programme HUPA of heating circulation pumps has been especially designed in technology, materials and production for a safe operation and long product life cycle. As for all Halm screw-connected pumps, due to the electrical connections being directly integrated into the pump, assembly is easy. Largesize terminal boxes do not exist. This saves space and time and facilitates mounting. Product features energetically optimised manual start-up feature space-saving axially integrated terminal box with three-stage switch for manual speed selection installation length: 130 / 180 mm standard connection: R ½ - 1¼ enclosure class: IP 44 insulation class: H media temperature: +2 C...+110 C (35.6 F... 230 F) capacity Q max.: 3.8 m³ / h pressure head H max.: 7 m Main areas of application Heating, air-conditioning and industrial applications as single and double pipe systems, underfl oor heating, boiler and primary circuits Media handled Heating water according to VDI 2035 Thin, clean, non-aggressive and non-explosive, mineral oil free liquids without solid particles or fi bres. Media with a viscosity of max. 10 mm² / s. For a glycol ratio of >20%, the operating data have to be checked. 15

Dimensions Product overview Installation length [mm] 180 130 Standard connection Pressure head [m] 2,5 4,0 5,0 6,0 7,0 R 1 x x x x x R 1¼ x x x x x R ½ x x x x x R 1 x x x x x Type overview Installation length [mm] 180 130 Type Standard connection Power consumption P1 [W] Nominal current [A] Efficiency class Item No. Weight [kg] HUPA 25-2.5 U 180 R 1 27... 35 0,12... 0,15 B 0323-33203 2,7 HUPA 25-4.0 U 180 R 1 33... 44 0,14... 0,19 B 0323-33204 2,7 HUPA 25-5.0 U 180 R 1 43... 77 0,19... 0,34 C 0323-33205 2,7 HUPA 25-6.0 U 180 R 1 43... 80 0,19... 0,34 C 0323-33206 2,8 HUPA 25-7.0 U 180 R 1 54... 97 0,24... 0,39 D 0323-33207 2,8 HUPA 30-2.5 U 180 R 1¼ 27... 35 0,12... 0,15 B 0324-33203 2,8 HUPA 30-4.0 U 180 R 1¼ 33... 44 0,14... 0,19 B 0324-33204 2,8 HUPA 30-5.0 U 180 R 1¼ 43... 77 0,19... 0,34 C 0324-33205 2,8 HUPA 30-6.0 U 180 R 1¼ 43... 80 0,19... 0,34 C 0324-33206 2,8 HUPA 30-7.0 U 180 R 1¼ 54... 97 0,24... 0,39 D 0324-33207 2,8 HUPA 15-2.5 U 130 R ½ 27... 35 0,12... 0,15 B 0321-33003 2,6 HUPA 15-4.0 U 130 R ½ 33... 44 0,14... 0,19 B 0321-33004 2,6 HUPA 15-5.0 U 130 R ½ 43... 77 0,19... 0,34 C 0321-33005 2,6 HUPA 15-6.0 U 130 R ½ 43... 80 0,19... 0,34 C 0321-33006 2,6 HUPA 15-7.0 U 130 R ½ 54... 97 0,24... 0,39 D 0321-33007 2,6 HUPA 25-2.5 U 130 R 1 27... 35 0,12... 0,15 B 0323-33003 2,6 HUPA 25-4.0 U 130 R 1 33... 44 0,14... 0,19 B 0323-33004 2,6 HUPA 25-5.0 U 130 R 1 43... 77 0,19... 0,34 C 0323-33005 2,6 HUPA 25-6.0 U 130 R 1 43... 80 0,19... 0,34 C 0323-33006 2,6 HUPA 25-7.0 U 130 R 1 54... 97 0,24... 0,39 D 0323-33007 2,6 16

Characteristics H [m] 3.0 HUPA... - 2.5 U H [m] 6.0 HUPA... - 4.0 U 2.5 5.0 2.0 4.0 1.5 3.0 1.0 2.0 0.5 1.0 0 0.0 Q [m 3 /h] 0.5 1.0 1.5 2.0 2.5 0 0.0 Q [m 3 /h] 1.0 2.0 3.0 4.0 5.0 H [m] 6.0 HUPA... - 5.0 U H [m] 6.0 HUPA... - 6.0 U 5.0 5.0 4.0 4.0 3.0 3.0 2.0 2.0 1.0 1.0 0 0.0 Q [m 3 /h] 1.0 2.0 3.0 4.0 5.0 0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Q [m 3 /h] H [m] 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0 0 HUPA... - 7.0 U 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Q [m 3 /h] 17

Product group HG Heating circulation pumps HGPA, pressure head up to 12 m, with screwed connection, non-controlled / 3 stages, 1x230 V, installation length 180 mm The new product range of circulation pumps HGPA from Halm was specially designed for heating systems, where both high pressure heads and capacities are required at one and the same time. As with all pumps with screwed connection from Halm, these products also have an axially integrated terminal box for simple, space-saving mounting and particularly good access to the electrical connections. Product features manual start-up feature axially integrated terminal box with three-stage switch for manual speed selection installation length: 180 mm standard connection: R 1-1¼ enclosure class: IP 44 insulation class: H media temperature: +2 C... +110 C (35.6 F... 230 F) capacity Q max.: 12 m³ / h pressure head H max.: 12 m Main areas of application Heating, air-conditioning and industrial applications as single and double pipe systems, underfl oor heating, boiler and primary circuits Media handled Heating water according to VDI 2035 Thin, clean, non-aggressive and non-explosive, mineral oil free liquids without solid particles or fi bres Media with a viscosity of max. 10 mm² / s. For a glycol ratio of >20%, the operating data have to be checked. 18

Dimensions Type overview Installation length [mm] 180 Type Standard connection Power consumption P1 [W] Nominal current [A] Item No. Weight [kg] HGPA 25-7.0 U 180 R 1 220... 260 1,03... 1,13 0323-41207 6,5 HGPA 25-8.0 U 180 R 1 260... 286 1,23... 1,25 0323-41208 6,5 HGPA 25-10.0 U 180 R 1 283... 357 1,35... 1,56 0323-41210 6,5 HGPA 25-12.0 U 180 R 1 285... 400 1,36... 1,73 0323-41212 6,5 HGPA 30-7.0 U 180 R 1¼ 220... 260 1,03... 1,13 0324-41207 6,6 HGPA 30-8.0 U 180 R 1¼ 260... 286 1,23... 1,25 0324-41208 6,6 HGPA 30-10.0 U 180 R 1¼ 283... 357 1,35... 1,56 0324-41210 6,6 HGPA 30-12.0 U 180 R 1¼ 285... 400 1,36... 1,73 0324-41212 6,6 19

Characteristics HGPA... - 7.0 HGPA... - 8.0 HGPA... - 10.0 HGPA... - 12.0 20

Product group UB Circulation pumps BUP for domestic water with screwed connection, non-controlled / 3 stages, 1x230 V, installation length 130 / 150 / 180 mm Halm circulation pumps BUP for domestic water offer special comfort in kitchen and bath due to immediate availability of warm or hot water. The resin-cast stator protects durably and reliably against the formation of condensation water. Product features particularly suitable for underfl oor heating with three-stage switch for manual speed selection condensation-water free bronze housing space-saving axially integrated terminal box resin-cast stator manual start-up feature installation length: 130 / 150 / 180 mm standard connection: R ½ - 1 enclosure class: IP 44 insulation class: H media temperature: +2 C... +110 C (35.6 F... 230 F) capacity Q max.: 5,0 m³ / h pressure head H max.: 6 m temperature class: TF 110 Main areas of application Drinking water systems in building and industrial installations for domestic, cooling and heating circuits, underfl oor heating Media handled Drinking water and heated drinking water with up to 65 C (149 F), max. 14 dh. Media with a viscosity of max. 10 mm² / s. 21

Dimensions Product overview Installation length [mm] 130 Standard connection Pressure head [m] 1,5 3,0 4,0 6,0 R ½ x x x x R 1 x x x x 150 R ¾ x x x x 180 R 1 x x Type overview Installation length [mm] 130 150 180 Type Standard connection Power consumption P1 [W] Nominal current [A] Item No. Weight [kg] BUP 15-1.5 U 130 R ½ 28... 58 0,16... 0,28 0331-0103 2,7 BUP 15-3.0 U 130 R ½ 33... 63 0,17... 0,3 0331-0104 2,7 BUP 15-4.0 U 130 R ½ 40... 70 0,27... 0,44 0331-0105 2,7 BUP 15-6.0 U 130 R ½ 56... 100 0,27... 0,44 0331-0107 2,7 BUP 25-1.5 U 130 R 1 28... 58 0,16... 0,28 0333-0103 2,7 BUP 25-3.0 U 130 R 1 33... 63 0,17... 0,3 0333-0104 2,7 BUP 25-4.0 U 130 R 1 40... 70 0,27... 0,44 0333-0105 2,7 BUP 25-6.0 U 130 R 1 55... 90 0,27... 0,44 0333-0107 2,7 BUP 20-1.5 U 150 R ¾ 28... 58 0,16... 0,28 0332-0113 2,7 BUP 20-3.0 U 150 R ¾ 33... 63 0,17... 0,3 0332-0114 2,7 BUP 20-4.0 U 150 R ¾ 40... 70 0,27... 0,44 0332-0115 2,7 BUP 20-6.0 U 150 R ¾ 56... 100 0,27... 0,44 0332-0117 2,7 BUP 25-4.0 U 180 R 1 40... 70 0,27... 0,44 0333-0125 2,8 BUP 25-6.0 U 180 R 1 56... 100 0,27... 0,44 0333-0127 2,8 22

Characteristics 23

Product group BG Circulation pumps BGPA for domestic water, pressure head up to 12m with screwed connection, non-controlled / 3 stages, 1x230 V, installation length 180 mm For the supply of domestic water with both high volumes and pressure heads the products of BGPA series have been developed. Similar to the smaller version BUP these pumps as well feature a bronze housing. The axially integrated terminal box and the comparably compact design allow for an easy, space-saving mounting and particularly simplifi ed access to the electical connections. Product features with three-stage switch for manual speed selection bronze housing space-saving axially integrated terminal box resin-cast stator manual start-up feature installation length: 180 mm standard connection: R ¾ - 1 enclosure class: IP 44 insulation class: H media temperature: +2 C... +110 C (35.6 F... 230 F) capacity Q max.: 12 m³ / h pressure head H max.: 12 m temperature class: TF 110 24

Main areas of application Drinking water systems in building and industrial installations for domestic, cooling and heating circuits Media handled Drinking water and heated drinking water with up to 65 C (149 F), max. 14 dh. Media with a viscosity of max. 10 mm² / s. Dimensions BGPA 25-12.0 U 180 Type overview Installation length [mm] 180 Type Standard connection Power consumption P1 [W] Nominal current [A] Item No. Weight [kg] BGPA 20-7.0 U 180 R ¾ 220... 260 1,03... 1,13 0332-41207 6,5 BGPA 20-8.0 U 180 R ¾ 260... 286 1,23... 1,25 0332-41208 6,5 BGPA 20-10.0 U 180 R ¾ 283... 357 1,35... 1,56 0332-41210 6,5 BGPA 20-12.0 U 180 R ¾ 285... 400 1,36... 1,73 0332-41212 6,5 BGPA 25-7.0 U 180 R 1 220... 260 1,03... 1,13 0333-41207 6,5 BGPA 25-8.0 U 180 R 1 260... 286 1,23... 1,25 0333-41208 6,5 BGPA 25-10.0 U 180 R 1 283... 357 1,35... 1,56 0333-41210 6,5 BGPA 25-12.0 U 180 R 1 285... 400 1,36... 1,73 0333-41212 6,5 25

Characteristics BGPA... - 7.0 BGPA... - 8.0 BGPA... - 10.0 BGPA... - 12.0 26

Product group S Circulation pumps SUP for solar systems with screwed connection, non-controlled / 3 stages, 1x230 V, installation length 130 / 180 mm The circulation pump SUP for solar systems was specially developed for pumping pure water or water-glycol mixtures in solar collector systems. The pumps are particularly temperature resistant and robust and are especially suitable for systems with high temperature gradients and high-fl ow design. Short-term media temperatures of up to 130 C (266 F) and pumping of water-glycol mixtures with a glycol proportion of up to 50% are possible without problems. Product features large capacity for high-fl ow systems cataphoretically coated housing particularly durable and robust resin-cast stator condensation-water free manual start-up feature installation length: 130 / 180 mm standard connection: R 1/2, R 1 enclosure class: IP 44 insulation class: H media temperature: -10 C... +110 C (14 F... 230 F), short-term (< 2h) up to 130 C (266 F) capacity Q max.: 5,5 m³ / h pressure head H max.: 6 m Main areas of application Solar systems, high-fl ow systems in particular Media handled Heating water according to VDI 2035 Thin, clean, non-aggressive and non-explosive, mineral oil free liquids without solid particles or fi bres. Media with a viscosity of max. 10 mm² / s. For a glycol ratio of >50%, the operating data have to be checked. 27

Dimensions Type overview Type Standard connection Power consumption P1 [W] Nominal current [A] Item No. SUP 15-4.0 U 130 R ½ 40... 70 0,19... 0,33 0311-21004 2,8 SUP 15-6.0 U 130 R ½ 56... 100 0,27... 0,44 0311-21006 2,8 SUP 25-4.0 U 180 R 1 40... 70 0,19... 0,33 0313-21204 2,8 SUP 25-6.0 U 180 R 1 56... 100 0,27... 0,44 0313-21206 2,8 Weight [kg] Characteristics SUP... 4.0 U SUP... 6.0 U 28

Product group K Circulation pumps KUP for geothermy, air-conditioning and refrigeration with screwed connection, non-controlled / 3 stages, 1x230 V, installation length 130 / 180 mm Especially high requirements are made on pumps which are permanently or over longer periods exposed to fl uid temperatures below the ambient temperature. The circulation pumps KUP were therefore designed for the specifi c requirements in air-conditioning and refrigeration applications with temperatures down to -25 C. Technology and materials were specifi cally designed for these particularly low temperatures. The almost completely resin-cast interior of the pump reliably and durably prevents the occurrence of condensation water. High fl ow quantities of up to 5.5 m³/h enable effi cient pumping of media with competitively low use of energy. Product features large capacity cataphoretically coated housing particularly durable and robust resin-cast stator condensation-water free resin-cast terminal box pre-mounted connection cable manual start-up feature installation length: 130 / 180 mm standard connection: R 1/2, R 1 enclosure class: IP 44 insulation class: H media temperature: -25 C... +110 C (-13 F... 230 F) capacity Q max.: 5,5 m³ / h pressure head H max.: 6 m Main areas of application Air-conditioning and refrigeration systems Media handled Thin, clean, non-aggressive and non-explosive, mineral oil free liquids without solid particles or fi bres. Media with a viscosity of max. 10 mm² / s. For a glycol ratio of >50%, the operating data have to be checked. 29

Dimensions Type overview Type Standard connection Power consumption P1 [W] Nominal current [A] Item No. KUP 15-4.0 U 130 R ½ 40... 70 0,19... 0,33 0311-11004 2,8 KUP 15-6.0 U 130 R ½ 56... 100 0,27... 0,44 0311-11006 2,8 KUP 25-4.0 U 180 R 1 40... 70 0,19... 0,33 0313-11204 2,8 KUP 25-6.0 U 180 R 1 56... 100 0,27... 0,44 0313-11206 2,8 Weight [kg] Further types on request. Characteristics KUP... 4.0 U KUP... 6.0 U 30

Product group KG Circulation pumps KGPA for geothermy, air-conditioning and refrigeration pressure head up to 12 m, with screwed connection, non-controlled / 3 stages, 1x230 V, installation length 180 mm Robust and reliable - that s how the KGPA for geothermy, air-conditioning and refrigeration have been designed. The condensation-water free delivery of media whose temperature is permanently below the ambient temperature is possible by means of a specifi cally designed drive unit. The pumps of this series are available with bronze housing as KGPB as well (on request). Product features large capacity cataphoretically coated housing particularly durable and robust condensation-water free resin-cast stator axial terminal box pre-mounted connection cable manual start-up feature with three-stage switch for manual speed selection installation length: 180 mm standard connection: R 1-1¼ enclosure class: IP 44 insulation class: H media temperature: -25 C... +110 C (-13 F... 230 F) capacity Q max.: 12 m³ / h pressure head H max.: 12 m 31

Main areas of application Geothermy, air-conditioning and refrigeration systems Media handled Thin, clean, non-aggressive and non-explosive, mineral oil free liquids without solid particles or fi bres. Media with a viscosity of max. 10 mm² / s. For a glycol ratio of >50%, the operating data have to be checked. Type overview Installation length [mm] 180 Type Standard connection Power consumption P1 [W] Nominal current [A] Item No. Weight [kg] KGPA 25-7.0 U 180 R 1 220... 260 1,03... 1,13 0313-51207 6,5 KGPA 25-8.0 U 180 R 1 260... 286 1,23... 1,25 0313-51208 6,5 KGPA 25-10.0 U 180 R 1 283... 357 1,35... 1,56 0313-51210 6,5 KGPA 25-12.0 U 180 R 1 285... 400 1,36... 1,73 0313-51212 6,5 KGPA 30-7.0 U 180 R 1¼ 220... 260 1,03... 1,13 0314-51207 6,6 KGPA 30-8.0 U 180 R 1¼ 260... 286 1,23... 1,25 0314-51208 6,6 KGPA 30-10.0 U 180 R 1¼ 283... 357 1,35... 1,56 0314-51210 6,6 KGPA 30-12.0 U 180 R 1¼ 285... 400 1,36... 1,73 0314-51212 6,6 Dimensions KGPA 25-12.0 U 180 32

Characteristics KGPA... - 7.0 KGPA... - 8.0 KGPA KGPA... - 10.0 KGPA... - 12.0 33

Product group U Heating circulation pumps HUP with condensation water protection, pressure head up to 6 m, with screwed connection, non-controlled / 3 stages, 1x230 V, installation length 130 / 180 mm The heating circulation pumps HUP have a resin-cast stator and thus offer long-lasting and reliable condensation water protection. The products are characterised by fl at characteristics, i.e. relatively high capacities also in case of low pressure heads. The pumps are preferably used in applications where pumping of media without condensation water is required. Product features resin-cast stator condensation-water free manual start-up feature with three-stage switch for manual speed selection installation length: 130 / 180 mm standard connection: R ½ - 1¼ enclosure class: IP 44 insulation class: H media temperature: -10 C... +110 C (14 F... 230 F) capacity Q max.: 5,0 m³ / h pressure head H max.: 6 m Main areas of application universally usable especially where pumping of media without condensation water is required Media handled Thin, clean, non-aggressive and non-explosive, mineral oil free liquids without solid particles or fi bres. Media with a viscosity of max. 10 mm² / s. For a glycol ratio of >50%, the operating data have to be checked. 34

Dimensions Product overview Installation length [mm] 180 130 Standard connection Pressure head [m] 1,5 2,5 4,0 5,0 6,0 R 1 x x x x x R 1¼ x x x x R ½ x x x x R ¾ x x x x x Type overview Installation length [mm] 180 130 Type Standard connection Power consumption P1 [W] Nominal current [A] Item No. Weight [kg] HUP 25-1.5 U 180 R 1 28... 58 0,16... 0,28 0323-0123 2,8 HUP 25-2.5 U 180 R 1 33... 63 0,17... 0,3 0323-0124 2,8 HUP 25-4.0 U 180 R 1 40... 70 0,19... 0,33 0323-0125 2,8 HUP 25-5.0 U 180 R 1 55... 90 0,25... 0,39 0323-0126 2,8 HUP 25-6.0 U 180 R 1 56... 100 0,27... 0,44 0323-0127 2,8 HUP 30-2.5 U 180 R 1¼ 33... 63 0,17... 0,3 0324-0124 2,9 HUP 30-4.0 U 180 R 1¼ 40... 70 0,19... 0,33 0324-0125 2,9 HUP 30-5.0 U 180 R 1¼ 55... 90 0,25... 0,39 0324-0126 2,9 HUP 30-6.0 U 180 R 1¼ 56... 100 0,27... 0,44 0324-0127 2,9 HUP 15-1.5 U 130 R ½ 28... 58 0,16... 0,28 0321-0103 2,7 HUP 15-2.5 U 130 R ½ 33... 63 0,17... 0,3 0321-0104 2,7 HUP 15-4.0 U 130 R ½ 40... 70 0,19... 0,33 0321-0105 2,7 HUP 15-6.0 U 130 R ½ 56... 100 0,27... 0,44 0321-0107 2,7 HUP 20-1.5 U 130 R ¾ 28... 58 0,16... 0,28 0322-0103 2,7 HUP 20-2.5 U 130 R ¾ 33... 63 0,17... 0,3 0322-0104 2,7 HUP 20-4.0 U 130 R ¾ 40... 70 0,19... 0,33 0322-0105 2,7 HUP 20-5.0 U 130 R ¾ 55...90 0,25... 0,39 0322-0106 2,7 HUP 20-6.0 U 130 R ¾ 56... 100 0,27... 0,44 0322-0107 2,7 35

Characteristics 36

Product group F Heating circulation pumps HUP and HUPD, pressure head up to 11 m, with flanged connection, non-controlled, 3x400 V, installation length 250 / 280 / 340 / 360 mm The heating circulation pumps HUP and HUPD with fl anged connection are particularly suitable for high fl ow volumes of up to 70 m³/h. With nominal sizes ranging from 40-80 mm these pumps offer excellent solutions for numerous areas of use and applications. Due to their equipment with stainless steel impellers and precision carbon bearings they are highly reliable and also most suitable for pumping water-glycol mixtures with a glycol ratio of up to 20%. Product features installation length: 250 / 280 / 340 / 360 mm standard connection: DN 40-80, PN 6 enclosure class: IP 43 insulation class: H media temperature: -10 C... +120 C (14 F... 248 F) capacity Q max.: 70 m³ / h pressure head H max.: 11 m Main areas of application Heating, air-conditioning and industrial applications as single or double pipe systems, underfl oor heating, boiler, primary circuits / cooling circuits and air-conditioning systems Media handled Heating water according to VDI 2035 Thin, clean, non-aggressive and non-explosive, mineral oil free liquids without solid particles or fi bres. Media with a viscosity of max. 10 mm² / s. For a glycol ratio of >20%, the operating data have to be checked. 37

Product overview Installation length [mm] Standard connection Pressure head [m] 3,0 4,0 6,0 11,0 250 DN 40 x x x 280 DN 50 x x x 340 DN 65 x x x 360 DN 80 x x Type overview Installation length [mm] 250 280 340 360 Type Standard connection Power consumption P1 [W] Nominal current 3x400 V [A] Item No. Weight [kg] HUP 40-4.0 U 250 DN 40 100... 240 0,11... 0,7 0325-9125 18,0 HUP 40-6.0 U 250 DN 40 140... 320 0,22... 0,75 0325-9127 18,0 HUP 40-11.0 U 250 DN 40 220... 560 0,34... 1,45 0325-9129 18,5 HUPD 40-4.0 U 250 DN 40 100... 240 0,11... 0,7 0325-9125.7 33,0 HUPD 40-6.0 U 250 DN 40 140... 320 0,22... 0,75 0325-9127.7 33,0 HUPD 40-11.0 U 250 DN 40 220... 560 0,34... 1,45 0325-9129.7 35,0 HUP 50-4.0 U 280 DN 50 120... 340 0,21... 1,0 0326-9125 23,0 HUP 50-6.0 U 280 DN 50 100... 470 0,20... 1,15 0326-9127 23,0 HUP 50-11.0 U 280 DN 50 330... 1100 0,46... 1,73 0326-9129 23,0 HUPD 50-4.0 U 280 DN 50 120... 340 0,21... 1,0 0326-9125.7 44,0 HUPD 50-6.0 U 280 DN 50 100... 470 0,20... 1,15 0326-9127.7 44,0 HUPD 50-11.0 U 280 DN 50 265... 950 0,46... 1,73 0326-9129.7 44,0 HUP 65-3.0 U 340 DN 65 120... 400 0,22... 1,1 0327-9125 27,5 HUP 65-6.0 U 340 DN 65 120... 600 0,22... 1,2 0327-9127 27,5 HUP 65-11.0 U 340 DN 65 460... 1560 0,84... 2,9 0327-9129 30,0 HUPD 65-3.0 U 340 DN 65 120... 400 0,22... 1,1 0327-9125.7 49,0 HUPD 65-6.0 U 340 DN 65 120... 600 0,22... 1,2 0327-9127.7 49,0 HUPD 65-11.0 U 340 DN 65 460... 1560 0,84... 2,9 0327-9129.7 54,0 HUP 80-6.0 U 360 DN 80 200... 960 0,42... 2,2 0328-9127 33,0 HUP 80-11.0 U 360 DN 80 550... 2200 1,16... 4,2 0328-9129 34,0 HUPD 80-6.0 U 360 DN 80 200... 960 0,42... 2,2 0328-9127.7 59,5 HUPD 80-11.0 U 360 DN 80 550... 2200 1,16... 4,2 0328-9129.7 61,0 38

Product group F Heating circulation pumps HUP and HUPD, pressure head up to 11 m, with flanged connection, non-controlled, 1x230 V, installation length 250 / 280 mm Product features installation length: 250 / 280 mm standard connection: DN 40-50, PN 6 enclosure class: IP 43 insulation class: H media temperature: -10 C... +120 C (14 F... 248 F) capacity Q max.: 70 m³ / h pressure head H max.: 11 m Main areas of application Heating, air-conditioning and industrial applications as single or double pipe systems, underfl oor heating, boiler, primary circuits / cooling circuits and air-conditioning systems Media handled Heating water according to VDI 2035 Thin, clean, non-aggressive and non-explosive, mineral oil free liquids without solid particles or fi bres. Media with a viscosity of max. 10 mm² / s. For a glycol ratio of >20%, the operating data have to be checked. Product overview Installation length [mm] Standard connection Pressure head [m] 6,0 11,0 250 DN 40 x x 280 DN 50 x x Type overview Installation length [mm] 250 280 Type Standard connection Power consumption P1 [W] Nominal current 1x230 V [A] Item No. Weight [kg] HUP 40-6.0 U 250 DN 40 210... 240 1,15... 1,19 0325-9127.1 18,0 HUP 40-11.0 U 250 DN 40 440... 500 1,85... 2,35 0325-9129.1 18,0 HUPD 40-6.0 U 250 DN 40 210... 240 1,15... 1,19 0325-9127.3 33,0 HUPD 40-11.0 U 250 DN 40 440... 500 1,85... 2,35 0325-9129.3 35,0 HUP 50-6.0 U 280 DN 50 180... 380 1,0... 1,85 0326-9127.1 23,0 HUP 50-11.0 U 280 DN 50 300... 700 1,7... 3,6 0326-9129.1 23,0 HUPD 50-6.0 U 280 DN 50 180... 380 1,0... 1,85 0326-9127.3 44,0 HUPD 50-11.0 U 280 DN 50 300... 700 1,7... 3,6 0326-9129.3 44,0 39

Dimensions 3x400 V and 1x230 V Type PN h h1 b b1 b2 a R l HUP 40 6 250 153 92 65 ¼ 198 HUPD 40 6 250 110 346 153 62 ¼ 198 HUP 50 6 280 160 113 70 ¼ 250 HUPD 50 6 280 121 400 160 70 ¼ 250 HUP 65 6 340 160 123 80 ¼ 252 HUPD 65 6 340 141 450 160 80 ¼ 252 HUP 80 6 360 160 129,5 100 ¼ 257 HUPD 80 6 360 146 470 160 95 ¼ 257 40

Characteristics 41

parallel connected pump single connected pump 42

Product group FE Heating circulation pumps HUP and HUPD, pressure head up to 10 m, with flanged connection, electronically controlled, 1x230 V, installation length 250 / 280 / 340 / 360 mm Product features installation length: 250 / 280 / 340 / 360 mm standard connection: DN 40-80, PN 6 enclosure class: IP 43 insulation class: H media temperature: -10 C... +110 C (14 F... 230 F) capacity Q max.: 65 m³ / h pressure head H max.: 10 m Main areas of application Heating, air-conditioning and industrial applications as single or double pipe systems, underfl oor heating, boiler, primary circuits / cooling circuits and air-conditioning systems Media handled Heating water according to VDI 2035 Thin, clean, non-aggressive and non-explosive, mineral oil free liquids without solid particles or fi bres. Media with a viscosity of max. 10 mm² / s. For a glycol ratio of >20%, the operating data have to be checked. Type overview Installation length [mm] 250 280 340 360 Type Standard connection HUP 40-6.0 E 250 DN 40 Speed [min- ¹] 700-2.800 Power consumption P1 [W] Nominal current [A] Item No. Weight [kg] 330 2,8 0325-9127.5 21 HUP 40-10.0 E 250 DN 40 650 5,2 0325-9129.5 21 HUPD 40-6.0 E 250 DN 40 330 2,8 0325-9127.9 38 HUPD 40-10.0 E 250 DN 40 650 5,2 0325-9129.9 40 HUP 50-6.0 E 280 DN 50 540 4 0326-9127.5 25 HUP 50-10.0 E 280 DN 50 1180 7,6 0326-9129.5 25 HUPD 50-6.0 E 280 DN 50 540 4 0326-9127.9 49 HUPD 50-10.0 E 280 DN 50 1180 7,6 0326-9129.9 49 HUP 65-6.0 E 340 DN 65 450 4 0327-9127.5 30 HUP 65-10.0 E 340 DN 65 1270 8,9 0327-9129.5 32 HUPD 65-6.0 E 340 DN 65 450 4 0327-9127.9 54 HUPD 65-10.0 E 340 DN 65 1270 8,9 0327-9129.9 59 HUP 80-6.0 E 360 DN 80 1090 7 0328-9127.5 35 HUPD 80-6.0 E 360 DN 80 1090 7 0328-9127.9 67 43

Dimensions DN b1 b2 b3 b4 l h h1 a R D1 D2 D3 D4 D5 40 200 92 148 417 247 250 110 65 1/4 40 100/110 150 150 14/19 50 205 123 148 457 304 280 121 70 1/4 50 110/145 165 165 14/19 65 205 123 148 501 304 340 141 80 1/4 65 130/145 185 185 14/19 80 205 128 148 506 304 360 146 100 1/4 80 150 200 200 19 44

Characteristics 45

Product group FE / NMT Heating circulation pumps NMT, pressure head up to 12 m, with ECM-technology, with flanged connection, electronically controlled, 1x230 V, installation length 250 / 280 / 340 / 360 mm In contrast to pumps of conventional design, the New Motor Technology pumps NMT are driven by electronically commutated permanent magnet motors. The magnets generate a permanent electromagnetic rotating fi eld, which reduces the power consumption of the pumps by up to 60%. The New Motor Technology pump NMT optimally adapts to the hydraulic requirements of a system, in comparison to other pumps of the same size saves energy and is, most importantly, safe and reliable. Types of regulation: optionally p or const. p. Product features installation length: 250 / 280 / 340 / 360 mm standard connection: DN 40-80, PN 6 enclosure class: IP 44 insulation class: H media temperature: -10 C... +110 C (14 F... 230 F) capacity Q max.: 65 m³ / h pressure head H max.: 14 m quick and easy installation high effi ciency, 60% lower power consumption drive: electronically commutated self-regulated permanent magnet motors the pumps are delivered in an ex-factory standard confi guration, changes to the setting can be made via Ethernet interface (RJ-45) Main areas of application Heating, air-conditioning and industrial applications as single and double pipe systems, underfl oor heating, boiler and primary circuits Media handled Heating water according to VDI 2035 Thin, clean, non-aggressive and non-explosive, mineral oil free liquids without solid particles or fi bres. Media with a viscosity of max. 10 mm² / s. For a glycol ratio of >20%, the operating data have to be checked. 46

Type overview Installation length [mm] 250 280 340 360 Type Standard connection Power consumption P1 [W] Nominal current [A] Item No. Weight [kg] NMT 40 DN 40 500 2,1 0325-8129.5 24 NMTD 40 DN 40 500 2,1 0325-8129.9 47 NMT 50 DN 50 900 3,1 0326-8129.5 31 NMTD 50 DN 50 900 3,1 0326-8129.9 60 NMT 65 DN 65 1100 4,2 0327-8129.5 36 NMTD 65 DN 65 1100 4,2 0327-8129.9 63 NMT 80 DN 80 1600 6,2 0328-8129.5 44 NMTD 80 DN 80 1600 6,2 0328-8129.9 81 Characteristics H [m] 16.0 14.0 12.0 10.0 8.0 6.0 4.0 2.0 0 NMT 40 / 50 / 65 / 80 0 10 20 30 40 50 60 70 80 90 Q [m 3 /h] 47

Dimensions DN b1 b4 l h h1 a NMT 40 40 198 321 250 65 NMTD 40 40 198 403 321 250 110 65 NMT 50 50 198 355 280 70 NMTD 50 50 198 403 355 280 121 70 NMT 65 65 198 369 340 80 NMTD 65 65 198 452 369 340 141 80 NMT 80 80 198 403 360 100 NMTD 80 80 198 462 403 360 146 100 b1 a l b4 h h h1 h/2 a DN l 255 255 DN 48

Product group Z accessories Unions Material Item No. R G Grey cast iron Steel, zinc plated Brass 4152-0001.1 ½ 1 4152-0001.2 ¾ 1¼ 4152-0001.3 1 1½ 4152-0001.4 1¼ 2 4152-0002.1 ½ 1 4152-0002.2 ¾ 1¼ 4152-0002.3 1 1½ 4152-0002.4 1¼ 2 4152-0005.1 ½ 1 4152-0005.2 ¾ 1¼ 4152-0005.3 1 1½ Scope of supply: complete set of unions (2 x insertion part, 2 x spigot nut) for one pump, without gaskets. Plug for Circulation Pumps ( Plug & Pump ) Screwable plug complete with motor end connection respectively socket only All-purpose for all Halm screw-connected pumps For easy, quick connection Description Item No. Plug, complete 3219-2201 Socket only 3219-2202 Further accessories on request. 49

Replacement lists Grundfos - Wilo - KSB - Biral - Speck - Halm Product group HP High efficiency pumps HEP, pressure head 4 m and 6 m, efficiency class A energetically optimised, with screwed connection, electronically controlled, 1x230 V, installation length 130 / 180 mm Grundfos Wilo KSB Biral Speck Halm Halm Item No. Alpha 2 15-40 - - - - HEP 15-4.0 E 180 0321-34204.5 Alpha 2 15-60 - - - - HEP 15-6.0 E 180 0321-34206.5 Alpha 2 25-40 Alpha Pro 25-40 Alpha 2 25-60 Alpha Pro 25-60 Alpha 2 32-40 Alpha Pro 32-40 Alpha 2 32-60 Alpha Pro 32-60 Stratos Eco 25 1/3 Riotronic Eco 25-40 A / AX 12-1 - HEP 25-4.0 E 180 0323-34204.5 Stratos Eco 25 1/5 Riotronic Eco 25-60 A / AX 13-1 - HEP 25-6.0 E 180 0323-34206.5 Stratos Eco 30 1/3 Riotronic Eco 30-40 A / AX 12-2 - HEP 30-4.0 E 180 0324-34204.5 Stratos Eco 30 1/5 Riotronic Eco 30-60 A / AX 13-2 - HEP 30-6.0 E 180 0324-34206.5 Product group HE Efficiency pumps HUE, pressure heads of 4 m and 6 m, efficiency class B energetically optimised, with screwed connection, electronically controlled, 1x230 V, installation length 130 / 180 mm Grundfos Wilo KSB Biral Speck Halm Halm Item No. Alpha + 25-40 Star-E 25/1-3 Riotronic S 25-40 MXE / MC 12-1 NE 25/30 HUE 25-4.0 E 180 0323-33204.5 Alpha + 25-60 Star-E 25/1-5 Riotronic S 25-60 MXE / MC 13-1 NE 25/50 N 25/64-E HUE 25-6.0 E 180 0323-33206.5 Alpha + 32-40 Star-E 30/1-3 Riotronic S 30-40 MXE / MC 12-2 NE 32/30 HUE 30-4.0 E 180 0324-33204.5 Alpha + 32-60 Star-E 30/1-5 Riotronic S 30-60 MXE / MC 13-2 NE 32/50 N 32/64-E HUE 30-6.0 E 180 0324-33206.5 50

Product group H Heating circulation pumps HUPA pressure head up to 7 m, energetically optimised, with screwed connection, non-controlled / 3 stages, 1x230 V, installation length 130 / 180 mm Grundfos Wilo KSB Biral Speck Halm Halm Item No. UPS 15-30 130 Star-RS 15/2 - MX / M 10-4 - HUPA 15-2.5 U 130 0321-33003 UPS 15-40 130 Star-RS 15/4 Rio C 15-40 130 MX / M 12-4 - HUPA 15-4.0 U 130 0321-33004 UPS 15-60 130 Star-RS 15/6 Rio C 15-60 130 MX / M 13-4 - HUPA 15-6.0 U 130 0321-33006 UPS 25-25 Star-RS 25/2 Rio C 25-25 MX / M 10-1 UPS 25-40 Star-RS 25/4 Rio C 25-40 MX / M 12-1 UPS 25-50 Star-RS 25/5 Rio C 22/50 MX / M 12-1 UPS 25-60 Star-RS 25/6 Rio C 25-60 MX / M 13-1 N 25/33 VA 25/2 N 25/33 VA 25/4 N 25/53 VA 25/52 N 25/33 VA 25/64 HUPA 25-2.5 U 180 0323-33203 HUPA 25-4.0 U 180 0323-33204 HUPA 25-5.0 U 180 0323-33205 HUPA 25-6.0 U 180 0323-33206 - - - MX / M 14-1 VA 25/64 HUPA 25-7.0 U 180 0323-33207 UPS 32-30 Star-RS 30/2 Rio C 30-25 MX / M 10-2 N 32/33 HUPA 30-2.5 U 180 0324-33203 UPS 32-40 Star-S 30/4 Rio C 30-40 MX / M 12-2 UPS 32-50 Star-RS 30/6 Rio C 32/60 MX / M 12-2 N 32/33 VA 32/43 N 32/53 VA 32/52 HUPA 30-4.0 U 180 0324-33204 HUPA 30-5.0 U 180 0324-33205 UPS 32-60 Star-RS 30/6 Rio C 30-60 MX / M 13-2 UPS 32-80 TOP-S 30/7 (OEM: TOP-RL 30/6.5 TOP-RL 30/7.5) N 32/53 VA 32/64 HUPA 30-6.0 U 180 0324-33206 - MX / M 14-2 VA 32/73 HUPA 30-7.0 U 180 0324-33207 Product group HG Heating circulation pumps HGPA, pressure head up to 12 m, with screwed connection, non-controlled / 3 stages, 1x230 V, installation length 180 mm Grundfos Wilo KSB Biral Speck Halm Halm Item No. - TOP-S 25/7 Rio 25-70 MX / M 14-1 VA 25/64 HGPA 25-7.0 U 180 0323-41207 UPS 25-80 - - MX / M 15-1 - HGPA 25-8.0 U 180 0323-41208 UPS 32-80 TOP-S 30/7 Rio 30-70 MX / M 14-2 VA 32/73 HGPA 30-7.0 U 180 0324-41207 - - Rio 30-70 - - HGPA 30-8.0 U 180 0324-41208 - TOP-S 30/10 Rio 30-100 MX / M 15-2 VA 32/86 HGPA 30-10.0 U 180 0324-41210 - - Rio 30-100 - - HGPA 30-12.0 U 180 0324-41212 51

Product group UB Circulation pumps BUP for domestic water with screwed connection, non-controlled / 3 stages, 1x230 V, installation length 130 / 150 / 180 mm Grundfos Wilo KSB Biral Speck Halm UP 15-14 B/N Z 15 * Riotherm C 20-10 R 12-1 E * Halm Item No. W 12 120 * BN 15 BUP 15-1.5 U 130 0331-0103 - - - W 13 - BUP 15-3.0 U 130 0331-0104 - - - W 14 - BUP 15-4.0 U 130 0331-0105 - - - W 14 - BUP 15-6.0 U 130 0331-0107 UP 20-14 / 15 B / N UPS 20-15 N Star-Z 20/1 * C 20-15 W 12 120 * - BUP 20-1.5 U 150 0332-0113 UP 20-30 N Star-Z 20/2 TOP-Z 20/4 C 20-30 W 13 - BUP 20-3.0 U 150 0332-0114 UP 20-42 N TOP-Z 20/4 - W 14 BA 25/41 BUP 20-4.0 U 150 0332-0115 - - - W 14 BA 25/43 BUP 20-6.0 U 150 0332-0117 - - - W 12 BN 20/22 150 BUP 25-1.5 U 130 0333-0103 - - Riotherm C 25-20 W 13 BN 20/22 150 BUP 25-3.0 U 130 0333-0104 - - - W 14 BN 20/43 150 BUP 25-6.0 U 130 0333-0107 UPS 25-40 B Star-Z 25/2 - W 14 BVA 25/41 BUP 25-4.0 U 180 0333-0125 UPS 25-60 B Star-Z 25/6 Riotherm C 25-60 W 14 BVA 25/43 BUP 25-6.0 U 180 0333-0127 *: observe different installation lengths 52

Product group S Circulation pumps SUP for solar systems with screwed connection, non-controlled / 3 stages, 1x230 V, installation length 130 / 180 mm Grundfos Wilo KSB Biral Speck Halm Halm Item No. - Star-ST 15/4 * - - - SUP 15-4.0 U 130 0311-21004 - Star-ST 15/6 * - - - SUP 15-6.0 U 130 0311-21006 Solar 25-40 Star-ST 25/4 - - - SUP 25-4.0 U 180 0313-21204 Solar 25-60 Star-ST 25/6 - - - SUP 25-6.0 U 180 0313-21206 *: observe different installation lengths Product group KG Circulation pumps KGPA for geothermy, air-conditioning, refrigeration with screwed connection, non-controlled / 3 stages, 1x230 V, installation length 130 / 180 mm Grundfos Wilo KSB Biral Speck Halm Halm Item No. - TOP-S 25/7 Rio 25-70 MX / M 14-1 VA 25/64 KGPA 25-7.0 U 180 0313-51207 UPS 25-80 - - MX / M 15-1 - KGPA 25-8.0 U 180 0313-51208 UPS 32-80 TOP-S 30/7 Rio 30-70 MX / M 14-2 VA 32/73 KGPA 30-7.0 U 180 0314-51207 - - Rio 30-70 - - KGPA 30-8.0 U 180 0314-51208 - TOP-S 30/10 Rio 30-100 MX / M 15-2 VA 32/86 KGPA 30-10.0 U 180 0314-51210 - - Rio 30-100 - - KGPA 30-12.0 U 180 0314-51212 53

Product group U Heating circulation pumps HUP with condensation water protection, pressure head up to 6 m, with screwed connection, non-controlled / 3 stages, 1x230 V, installation length 130 / 180 mm Grundfos Wilo KSB Biral Speck Halm Halm Item No. UPS 15-20 130 Star RS 15/2 Rio C 15-15 130 MX / M 10-4 - HUP 15-1.5 U 130 0321-0103 UPS 15-30 130 Star-RS 15/2 - MX / M 10-4 - HUP 15-2.5 U 130 0321-0104 UPS 15-40 130 Star-RS 15/4 Rio C 15-40 130 MX / M 12-4 - HUP 15-4.0 U 130 0321-0105 UPS 15-60 130 Star-RS 15/6 Rio C 15-60 130 MX / M 13-4 - HUP 15-6.0 U 130 0321-0107 UPS 20-20 130 Star-RS 25/2 - MX / M 10-3 - HUP 20-1.5 U 130 HUP 20-2.5 U 130 0322-0103 0322-0104 UPS 20-40 130 Star-RS 25/4 Rio C 12/40 MX / M 12-3 N 20/33 AU 20/43 180 HUP 20-4.0 U 130 0322-0105 UPS 20-50 130 Star-RS 25/5 - MX / M 12-3 - HUP 20-5.0 U 130 0322-0106 UPS 20-60 130 Star-RS 25/6 Rio C 12/60 MX / M 13-3 AU 20/64 180 HUP 20-6.0 U 130 0322-0107 UPS 25-20 Star-RS 25/2 Rio C 25-15 MX / M 10-1 - HUP 25-1.5 U 180 0323-0123 UPS 25-25 Star-RS 25/2 Rio C 25-25 MX / M 10-1 UPS 25-40 Star-RS 25/4 Rio C 25-40 MX / M 12-1 UPS 25-50 Star-RS 25/5 Rio C 25-50 MX / M 12-1 UPS 25-60 Star-RS 25/6 Rio C 25-60 MX / M 13-1 N 25/33 VA 25/2 N 25/33 VA 25/4 N 25/53 VA 25/52 N 25/33 VA 25/64 HUP 25-2.5 U 180 0323-0124 HUP 25-4.0 U 180 0323-0125 HUP 25-5.0 U 180 0323-0126 HUP 25-6.0 U 180 0323-0127 UPS 32-30 Star-RS 30/2 Rio C 30-25 MX / M 10-2 N 32/33 HUP 30-2.5 U 180 0324-0124 UPS 32-40 Star-RS 30/4 Rio C 30-40 MX / M 12-2 UPS 32-50 Star-RS 30/6 Rio C 32/60 MX / M 12-2 UPS 32-60 Star-RS 30/6 Rio C 30-60 MX / M 13-2 N 32/33 VA 32/43 N 32/53 VA 32/52 N 32/53 VA 32/64 HUP 30-4.0 U 180 0324-0125 HUP 30-5.0 U 180 0324-0126 HUP 30-6.0 U 180 0324-0127 54

Product group F Heating circulation pumps HUP and HUPD, pressure head up to 11 m, with flanged connection, non-controlled, 3x400 V, installation length 250 / 280 / 340 / 360 mm Grundfos Wilo KSB Biral Speck Halm UPS 40-30 F TOP-S 40/4 Riovar 44-8 D Rio 40-40 Halm Item No. LX 403 - HUP 40-4.0 U 250 0325-9125 UPS 40-60 F TOP-S 40/7 Riovar 44-18 D Rio 40-70 HX 402-1 - HUP 40-6.0 U 250 ** 0325-9127 UPS 40-120 F TOP-S 40/10 Rio C 40-100 HX 402-1 - HUP 40-11.0 U 250 ** 0325-9129 UPS 50-30 F TOP-S 50/4 UPS 50-60 F TOP-S 50/7 UPS 50-120 F TOP-S 50/10 Riovar 54-18 D Rio 50-40 Riovar 54-30 D Rio 50-70 Riovar 54-100 D Rio 50-100 LX 503 * - HUP 50-4.0 U 280 0326-9125 LX 504 * - HUP 50-6.0 U 280 ** 0326-9127 HX 502-1 - HUP 50-11.0 U 280 ** 0326-9129 UPS 65-30 F - Riovar 64-30 D LX 653 * LX 652 * - HUP 65-3.0 U 340 0327-9125 UPS 65-60 F TOP-S 65/7 UPS 65-120 F TOP-S 65/10 UPS 80-60 F TOP-S 80/7 Riovar 64-48 D Rio 65-70 Riovar 64-48 D Rio 65-100 Riovar 84-48 D Rio 80-70 LX 654 - HUP 65-6.0 U 340 0327-9127 HX 652 - HUP 65-11.0 U 340 0327-9129 LX 803 * - HUP 80-6.0 U 360 0328-9127 UPS 80-120 F TOP-S 80/10 Riovar 84-75 D Rio 80-100 HX 802 L 805 - HUP 80-11.0 U 360 0328-9129 UPSD 40-30 F - Riovar Z 44-8 D LXD 403 - HUPD 40-4.0 U 250 0325-9125.7 UPSD 40-60 F TOP-SD 40/7 Riovar Z 44-18 D Rio Z 40-70 HXD 402-1 - HUPD 40-6.0 U 250 ** 0325-9127.7 UPSD 40-120 F TOP-SD 40/10 Rio Z 40-100 HXD 402-1 - HUPD 40-11.0 U 250 ** 0325-9129.7 UPSD 50-30 F - Riovar Z 54-18 D LXD 503 * - HUPD 50-4.0 U 280 0326-9125.7 UPSD 50-60 F TOP-SD 50/7 Riovar Z 54-30 D LXD 504 * - HUPD 50-6.0 U 280 ** 0326-9127.7 UPSD 50-120 F TOP-SD 50/10 Rio Z 50-100 HXD 502-1 - HUPD 50-11.0 U 280 ** 0326-9129.7 UPSD 65-30 F DOP-65/125r Riovar Z 64-30 D LXD 653 * - HUPD 65-3.0 U 340 0327-9125.7 UPSD 65-60 F DOP-65/160r Riovar Z 64-48 D LXD 654 - HUPD 65-6.0 U 340 0327-9127.7 UPSD 65-120 F TOP-SD 65/10 Riovar Z 64-48 D Rio Z 65-100 HXD 652 - HUPD 65-11.0 U 340 0327-9129.7 UPSD 80-60 F DOP-80/160r Riovar Z 84-75 D LXD 803 * - HUPD 80-6.0 U 360 0328-9127.7 UPSD 80-120 F TOP-SD 80/10 Rio Z 80-100 *: observe different installation lengths **: also available for 230 V HXD 802 LD 805 - HUPD 80-11.0 U 360 0328-9129.7 55

Product group FE Heating circulation pumps HUP and HUPD, pressure head up to 10 m, with flanged connection, electronically controlled, 1x230 V, installation length 250 / 280 / 340 / 360 mm Grundfos Wilo KSB Biral Speck Halm Halm Item No. - TOP-E 40/1-4 Riotec 40-40 LXE 403 NE 40/40 L HUP 40-6.0 E 250 0325-9127.5 UPE 40-120F Stratos 40 Riotec 40-100 HXE 402-1 NE 40/100 L HUP 40-10.0 E 250 0325-9129.5 UPE 50-60F TOP-E 50/1-6 Riotec 50-60 LXE 504 * NE 50/70 L HUP 50-6.0 E 280 0326-9127.5 UPE 50-120F Stratos 50 Riotec 50-100 HXC 501-1 NE 50/100 L HUP 50-10.0 E 280 0326-9129.5 UPE 65-60F TOP-E 50/1-10 Riotec 65-100 LXC 655 - HUP 65-6.0 E 340 0327-9127.5 UPE 65-120F Stratos 65 Riotec 65-100 - NE 65/100 L HUP 65-10.0 E 340 0327-9129.5 UPE 80-120F Stratos 80 Riotec 80-100 Riotec 80/1-10 LC 805 * NE 80/100 L HUP 80-6.0 E 360 0328-9127.5 - TOP-ED 40/1-7 Riotec Z 40-40 LXED 403 - HUPD 40-6.0 E 250 0325-9127.9 UPED 40-120F TOP-ED 40/1-10 Riotec Z 40-100 HXED 402-1 - HUPD 40-10.0 E 250 0325-9129.9 UPED 50-60F TOP-ED 50/1-6 Riotec Z 50-60 LXED 504 * - HUPD 50-6.0 E 280 0326-9127.9 UPED 50-120F TOP-ED 50/1-10 Riotec Z 50-100 HXCD 501-1 - HUPD 50-10.0 E 280 0326-9129.9 UPED 65-60F - Riotec Z 65-100 LXCD 655 - HUPD 65-6.0 E 340 0327-9127.9 UPED 65-120F TOP-ED 65/1-10 Riotec Z 65-100 - - HUPD 65-10.0 E 340 0327-9129.9 UPED 80-120F TOP-ED 80/1-10 Riotec Z 80-100 Riotec Z 80/1-10 LCD 805 * - HUPD 80-6.0 E 360 0328-9127.9 *: observe different installation lengths Product group FE / NMT Heating circulation pumps NMT, pressure head up to 12 m, with ECM-technology, with flanged connection, electronically controlled, 1x230 V, installation length 250 / 280 / 340 / 360 mm Grundfos Wilo KSB Biral Speck Halm Halm Item No. Magna 40-100 / 120F TOP-E 40/1-10 Riotec 40-100 A 402-1 NE 40-40/100 NMT 40 0325-8129.5 Magna 50-60 / 100 / 120F TOP-E 50/1-10 Riotec 50-100 A 502 NE 50-70/100 NMT 50 0326-8129.5 Magna 65-60 / 120F TOP-E 65/1-10 Riotec 65-100 A 652 NE 65-100 NMT 65 0327-8129.5 - TOP-E 80/1-10 Riotec 80-100 - NE 80-100 NMT 80 0328-8129.5 56

effiziente Pumpentechnologie Richard Halm GmbH + Co. KG Silcherstrasse 54-58 73666 Baltmannsweiler Germany P. O. Box 69 73664 Baltmannsweiler Germany Phone: +49 (0)7153-9202-0 Fax: +49 (0)7153-49168 E-mail: info@halm.info www.halm.info Your representative: Art.-No. 4308-0126-GB Version 3.0 (02/2009)