Ceiling Slot Diffuser Model DSX

Similar documents
Ceiling Slot Diffuser DSC

Ceiling Slot Diffuser DSC

Ceiling Slot Diffuser DSC

Ceiling diffuser 4DF

Swirl Diffuser Model DQF

Ventilation grille Model AL

Ceiling diffuser 4DE

DSC-PLASTER Slot diffuser for plasterboard ceilings

Nozzle Jet Diffuser Model DSA

Ventilation Grille PA

Ceiling impulse diffuser Model PIL

ceiling swirl diffuser Model DQJA / DQJR

ceiling swirl diffuser DQJ

Swirl Diffuser DHV Contents Description...3 Models and dimensions...4 Technical data...8

WGA Long throw nozzle grille

Round duct diffuser DBB-RR

Round duct grille Model KG-RR

Air diffuser system Model AUDIX -AW

Compact Grille Model KG

Ceiling Swirl Diffuser DQJ

LAQ Return air diffuser

Lint separator FLARE

Ventilation grille Model IB-R

Ceiling induction diffuser DISA-300

Ceiling induction diffuser DISA-601

Long Throw Nozzle WDA

Mechanical mixing box MBM

Volumetric Flow Limiter VOLKOM

Particle Filter Box Model FKF

DRUM SLOT DIFFUSER TYPE: RT350

Weather protection grille ALAS

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Particle Filter Box FKU

Slot diffusers for ceiling installation

Technical documentation

Ceiling swirl diffusers with perforated face plate

Round Duct System Model RR-Complete

WALL VENTILATION GRILLES CBP

Round Duct System Model RR-Complete

Round Duct System Accessories RR - accessories

Ceiling swirl diffusers

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

SLOT DIFFUSERS, ROUND DUCT DIFFUSERS

Slot diffusers, Round duct diffusers. IMP Klima

Ceiling swirl diffusers with perforated face plate

ADJUSTABLE SLOT DIFFUSER TYPE: SE800

Ceiling swirl diffusers

Ceiling swirl diffusers

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

2/1/EN/3. Slot Diffuser. Type VSD15. with 15 mm wide diffuser face

Type VSD35. Nominal length up to 1500 mm: one spigot

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser

series 90-GV Variable geometry units

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

CNVA TECHNICAL DOCUMENTATION. Active floor convector. Contents

LINEAR SLOT DIFFUSERS

HIGH CAPACITY LINEAR SLOT DUFFUSERS

Powder coating RAL, Satin anodized 11µm. Powder coated extruded aluminium. With mounting brackets on SPS plenum box. Fixed mounting on SPB plenum box

Incorporating V2.0. Product spec >>> > Series DJ - Drum jet diffusers

Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex

Fan coil unit NBS 100/150

series Linear grilles

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

Grilles Linear Grilles

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES

Catalog Swirl diffuser DAL 359

Linear Slot Diffusers Model Slot 20 & Model Slot 25

Ventilation grilles for installation into walls, sills or rectangular

Slot diffusers Type ALS

Displacement flow diffusers. L e

Product Nomenclature G-X-AB-Z 0 = Zero Degree, 1 = 15 Degree, 2 = 15 Degree (2-way)

DFA - Conical Ceiling Diffuser. Halton DFA. Conical Ceiling Diffuser

PRODUCT BROCHURE. Rectangular Displacement Diffuser RDW-FD RDW-FD : smartemp.com

BSK-EN Fire damper INSTALLATION, MOUNTING AND OPERATING INSTRUCTIONS

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

ISF-AD. Inclined Floor Swirl Diffuser PRODUCT BROCHURE. Optional Features: Constant throw height adjustable airflow rate Electrical VAV operation

ADJUSTABLE PERFORATED AIR SUPPLY DIFFUSER TYPE: DC560S

Incorporating V2.1. Product spec >>> > Series ECG - Egg crate grilles

MADEL. RMT eggcrate grilles. klin SYSTEM. The RMT-A series grilles are designed to be used in air-conditioning, ventilation, and heating.

Linear Slot Diffusers Model Slot 20 and Model Slot 25

Incorporating V2.0. Product spec >>> > Series DD - Double deflection grilles

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

Accessories. Balancing plenum PRI For balancing & equalising the airflow and attenuating the duct noise

IMP Klima. Swirl diffusers. Variable swirl diffusers

series KFD-KLD Linear slot diffusers

Powder coating RAL, Satin anodized 11µm. Powder coated extruded aluminium. With mounting brackets on SPS plenum box. Fixed mounting on SPB plenum box

THB - Perforated Ceiling Diffuser. Halton THB. Perforated Ceiling Diffuser

series KLR Linear slot diffusers

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser

Air Distribution SWIRL DIFFUSERS DW SERIES SERIES

Floor Swirls Models BZD and SZD

2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m

Krantz. Floor displacement outlet Q-B-DN 200. Air distribution systems

Grilles Linear Grilles

C O L M A N. Air Distribution PERFORATED FACE DIFFUSERS P SERIES SERIES

Transcription:

Ceiling Slot Diffuser Model DSX Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de

Contents Description...3 Construction... 3 model... 3 Accessories... 4 Fastening... 4 Models and dimensions...5 Air throw pattern... 5 Dimensions... 6 Dimensions of accessories... 7 Fastening methods... 14 Installation... 14 Technical data... 15 Pressure loss and noise level... 15 Maximum end velocity of jet... 17 Critical throw... 18 Maximum penetration... 18 Induction ratios... 18 Legend... 19 Order details... 20 Specification texts... 22 04/03-2

Description The small ceiling slot diffuser type DSX-S is suitable for installation in closed ceiling systems, in rooms of heights 2.6 to 4 m. In panelled ceilings, the use of the black (RAL 9005) air guide element allows an approximately invisible installation of the slot diffuser. The models DSX-P, DSX-PA and DSX-PB with support profile are suitable for installation in ceiling panels. Adjustments of the blades enable the diffuser to be used for cooling and heating applications. The high induction ensures fast reduction of the air outflow velocity and of the temperature difference in cooling mode. In heating mode, the vertical air throw guarantees a high penetration depth. Thus, the room can be heated quickly and effectively. The air throw direction can be adjusted from below, even after installation. In doing so, the free cross-section always remains constant. Likewise, the pressure loss and noise level do not change. A subsequent adjustment of the air jet pattern to changed room conditions is possible. To adjust the position of the blades, each blade must be pulled out and inserted rotated in accordance with the desired air direction. One- or two-way horizontal air throw and vertical air throw are possible. If, on ordering, the desired air throw direction is specified, it will be set ex works. Unless stated otherwise, blade position III (horizontal throw in alternating directions) will be set. The stable air jet means that the diffuser is suitable for VAV systems. Even at a volumetric flow of 40%, the jet still remains stable. The attached plenum box ensures a uniform distribution of the supply air over the whole area of the diffuser. At an extra charge, a damper adjustable from below can be installed in the connection spigot for air volume regulation. The plenum box can also be insulated either internally or externally. Connection to diffuseres combined with lighting is possible (price on request). A band design with plenum box is delivered with concealed mounting as standard. If the order does not specifiy the band design or if it is not obvious from the order documentation that the band design has been ordered, the individual grilles will be delivered with fixed connection to the plenum box. For slot diffusers in band design with concealed mounting, the fastening effort is reduced by half, compared with the model without concealed mounting. The ceiling slot diffuser DSX has been tested successfully by TÜV SÜD in accordance with the following regulations: - VDI 6022, Sheet 1: Hygienic requirements of ventilation and air-conditioning systems - VDI 6022, Sheet 2: Hygienic requirements of ventilation and air-conditioning systems - Measurement methods and investigations during hygienic controls and hygienic inspections. - VDI 6022, Sheet 2: Air-conditioning technology - Health requirements Diffuser mounting Fixing lugs are provided in the plenum box to allow the diffuser to be suspended (see page 6). These fixing lugs can be provided with M4 riveting nuts at an extra charge. Construction Air guide elements - Plastic, similar to RAL colour 9010 (white (-LW)) or RAL 9005 (black (-LS)) Frame - Extruded aluminium profile - DSX-S: painted to the colour of the air guide blades RAL 9010 (white) or RAL 9005 (black) - DSX-P, DSX-PA, DSX-PB: painted to RAL 9010 (white) or anodised in natural colour (E6/EV1) model DSX-S - for invisible installation, without support profile DSX-P - for visible installation, with support profile. DSX-PA - for visible installation, with support profile DSX-PB - for visible installation, with support profile. DSX-...-1/2/3/4-1-, 2-, 3-, or 4-slot DSX-...-Z - Supply air DSX-...-A - Return air with air guide elements DSX-...-L I - Air guide elements vertical throw DSX-...-L II L - Air guide elements one-way horizontal throw on the left DSX-...-L II R - Air guide elements one-way horizontal throw on the right DSX-...-L III - Air guide elements alternating horizontal throw (standard) 04/03-3

Accessories Plenum box (-ASK) - Galvanised sheet steel, with lateral connection spigot and fixing lugs. Damper (-DK) - Damper fastening made of plastic - Damper made of galvanised perforated sheet Corner angle 90 (-EW) - Extruded aluminium profile (in same colour as DSX) M4 riveting nut - at an extra charge End piece (pair) (-ES) - supplied unassembled as standard. If there are order details regarding fitting, mounting will take place at the factory. - ES1 for DSX-S, painted aluminium RAL 9005 (black) or RAL 9010 (white) - ES2 for DSX-P, natural anodised aluminium E6/EV1, or aluminium painted to RAL 9010 (white) - ES3 for DSX-PB, anodised aluminium in natural colour E6/ EV1, or painted aluminium RAL 9010 (white). Rubber lip seal (-GD) - Special rubber Internal insulation (-Ii) - thermal insulation at the inside of the plenum box External insulation (-Ia) - thermal insulation at the outside of the plenum box Dummy piece (-BS) - with dummy plate made of galvanised sheet steel - with M4 riveting nut Mounting bracket (pair) (-BW) for operation with overflow air - Galvanised sheet steel - with M4 riveting nut Connection element 1 - Galvanised sheet steel - for connection of plenum box with band design - supplied loose as standard Connection element 3 - for connection of DSX-... and dummy pieces with band design - supplied loose as standard Double blade - for connection of diffusers with band design Fastening permanent connection - Standard for models DSX-S, DSX-P, DSX-PA and DSX-PB Clamp fastening - Installation of the DSX-P and DSX-PB without plenum box in pressure ceilings. - supplied loose as standard Concealed mounting (-VM) - Standard for band design with plenum box (-ASK) - available for single diffusers with plenum box (-ASK) 04/03-4

Models and dimensions Air throw pattern Air guide element position (throw direction): vertical (-L I) Air guide blade one-way horizontal throw to the left (-L II L) one-way horizontal throw to the right (-L II R) alternate horizontal throw (-L III, standard) all adjacent blades will be set in one direction when ordering multi slot models Return air 04/03-5

Dimensions DSX-S, without support profile For installation in closed ceiling systems or for invisible installation in the joint of panelled ceilings. DSX-P: with support profile For installation in ceiling panels, suitable for installation in closed ceiling systems. DSX-PA, with support profile For installation in closed ceiling systems 42 anodised model painted model 56 anodised model painted model 71 anodised model painted model 85 anod. model paint. model DSX-PB, with support profile For installation in ceiling panels, suitable for installation in closed ceiling systems. 04/03-6

Dimensions of accessories Plenum box (-ASK) for DSX-S / DSX-P / DSX-PA / DSX-PB View A with 1 spigot with 2 connection pieces KH GH = Height of plenum box = Total height Detail X / diffuser mounting Standard: at an extra charge: on site on site riveting nut M4 View Z To facilitate ceiling mounting, the plenum boxes can be provided with an M4 riveting nut. This is to be carried out on site if diffusers are ordered without plenum boxes. Available sizes ød L < 500 500 < L < 1000 1000 < L < 1500 DSX-...-1 ø 98 ø 98 ø123 DSX-...-2 ø 98 ø123 2 x ø123 DSX-...-3 ø123 ø123 2 x ø123 DSX-...-4 ø123 2 x ø123 2 x ø123 Insulation for plenum box internal (-Ii) Damper (-DK) Rubber lip seal (-GD) Detail Y external (-Ia) 04/03-7

Band design DSX-... without end piece Double blade Band design DSX-... with end piece X t DSX-S 1 - DSX-P 10 3 DSX-PB 16 2,5 DL = Difference distance BL = Length of band L = 500/1000/1500mm Double blade DSX-S Detail a, without end piece DSX-S Detail b, with end piece DSX-P / DSX-PB Detail a, without end piece DSX-P / DSX-PB Detail b, with end piece When the ceiling slot diffuser type DSX is designed as a band > 2000 mm, the total length BL is assembled from standard lengths L = 1500 mm. The difference pieces <1500 mm to >400 mm can be fitted with a plenum box. The difference pieces <400 mm are supplied as dummy pieces without plenum box. A different band division is possible after consultation and when required by the customer. Individual sections are connected (for mounting on site) by using double blades. 04/03-8

Double blade Detail of connection element 1 Connection element 1 not possible when diffuser is suspended with riveting nut and band design is used. Mounting handle for double blade Double blade active - passive Detail of connection element 3 Fastening screw: Torx screw M4 DIN 7991-TX Connection element 3 passive - passive Fastening screw: Torx screw M4 DIN 7991-TX Connection element 3 04/03-9

Dummy piece (-BS) Mounting bracket (pair) (-BW) for operation with overflow air DSX-S-1 W Detail W DSX-S-1 V Detail V DSX-S-2 DSX-S-2 DSX-S-3 DSX-S-3 DSX-S-4 DSX-S-4 Arrangement of the mounting holes in the dummy plate DSX-...-1 (1-slot) with 2 mounting holes Arrangement of the mounting holes DSX-...-1 (1-slot) with 2 mounting holes DSX-...-2 to DSX-...-4 (2- to 4-slot) with 4 mounting holes DSX-...-2 to DSX-...-4 (2- to 4-slot) with 4 mounting holes In the dummy design, no operation with overflow air is possible since the slot diffuser is completely closed at the back. DSX-...- 1 2 3 4 A 35 49 63 77 DSX-...- 1 2 3 4 A 35 49 63 77 04/03-10

Band design for operation with overflow air or dummy plates Additional connecting fishplates In the band design for operation with overflow air or dummy plates, two additional fishplates are supplied loose, thus only requiring two threaded bars on-site for suspension. 04/03-11

End piece (-ES) To give the impression of a surrounding frame, side end pieces can be installed (for an additional charge). These end pieces are supplied loose as standard. If there are order details regarding fitting, mounting will take place at the factory. for DSX-S (-ES1) x t ES1 1 - ES2 10 3 ES3 16 2,5 for DSX-P (-ES2) / for DSX-PB (-ES3) End piece on both sides (-ES2 / -ES3) End piece on the left (-ES2 / -ES3) End piece on the right (-ES2 / -ES3) When the end pieces are mounted at the factory, it is essential to specify in the order whether the end piece is to be attached to both sides, or the left- or right-hand side. 04/03-12

Corner angle (-EW) (1- to 4-slot) Sections DSX-S A-A B-B Corner angles can only be produced as dummy pieces, i.e., without a plenum box. The corner angle has a 90 angle and is 250 mm long. Other angles are available on request The dummy plate is painted in the colour RAL 9005 (black) or RAL 9010 (white). The corner brackets are supplied loose as standard. s (mm) DSX-P 8,5 DSX-PB 14,5 DSX-P / DSX-PB A-A B-B Fishplate firmly screwed for the on-site connection with slot diffuser + double blade loose 04/03-13

Fastening methods Clamp fastening for DSX-P and DSX-PB in mounting position Concealed mounting (-VM) with plenum box DSX-...-1 to DSX-...-4 (1- to 4-slot) M4 riveting nut Connecting plate Torx screw M4 DIN 7991-TX in clamping position Installation Fitting to air-handling lights Air-handling light DSX-P 1 DSX-PB1 DSX-P 2 DSX-PB2 (not possible for model DSX-S!) DSX-P 3 DSX-PB3 DSX-P 4 DSX-PB4 B 58 72 86 100 Clamp fastening is used for room side installation in finished pressure ceilings. Standard profile Special profile "S" Mounting instructions As standard, the clamp straps are delivered loose. Take out the air guide elements at the ends. Fasten the clamp strap with the screw such that it is positioned in the direction of the slot diffuser (see installation position). Then introduce the slot diffuser into the pressure ceiling. Then rotate the clamp strap by about 90 by rotating the screw and lower it over the slot diffuser profile (see clamping position). Tighten the screw until the slot diffuser is firmly locked at the ceiling. Finally, re-insert the air guide elements. When fitted to air-handling lights, the external profile of the DSX-S is attached to the mounting side to ensure a perfectly flush fit. Otherwise the measurements correspond to the standard plenum box. 04/03-14

Technical data Pressure loss and noise level L=1000 (supply air) DSX-...-1 with ASK DSX-...-2 with ASK DSX-...-3 with ASK DSX-...-4 with ASK Damper position (0% = CLOSED / 100% = OPEN) 04/03-15

L = 1000 (return air), with air guide elements DSX-...-1 with ASK DSX-...-2 with ASK DSX-...-3 with ASK DSX-...-4 with ASK Length correction factor for noise level (supply and exhaust air) with air guide elements L (m) 1 1,5 2 2,5 3 4 5 KF (-) 0,0 1,8 3,0 4,0 4,7 6,0 7,0 Damper position (0% = CLOSED / 100% = OPEN) 04/03-16

Maximum end velocity of jet Blade position II (supply air) (one-way horizontal throw, left / right) Blade position III (supply air) (two-way horizontal throw) left right on both sides In the case of multi-slot models, all air guide elements which are side by side are inserted for one-way throw direction. DSX-...-1 (1-slot) DSX-...-1 (1-slot) DSX-...-2 (2-slot) DSX-...-2 (2-slot) DSX-...-3 (3-slot) DSX-...-3 (3-slot) DSX-...-4 (4-slot) DSX-...-4 (4-slot) 04/03-17

Critical throw Air guide blade positions II + III (one-way horizontal throw on the left side or on the right side + on both sides) Induction ratios Air guide blade position II (one-way horizontal throw left or right) 2-slot x kr x 1.5 3-slot x kr x 1.8 4-slot x kr x 2.2 Maximum penetration In heating mode Air guide blade position I Air guide elements position III (two-way horizontal throw) 04/03-18

Legend V ZU (m³/h m S)= Volumetric flow per metre per slot V ZU [l/s m S] = Volumetric flow per metre per slot Δp t (Pa) = Pressure loss ρ (kg/m³) = Density L WA [db(a)] = A-weighted sound power level (L WA - L WA1 + KF) L WA1 [db(a)] = A-weighted sound power level in case of L = 1000 x kr (m) = Critical throw ΔT O (K) = Temperature difference between supply air and room temperature (ΔT O = t ZU - t R ) ΔT X (K) = Temperature difference at point x v max (m/s) = Maximum end velocity of jet v (m/s) = Average end velocity of jet (v = v max x 0.5) TV (-) = Temperature ratio (TV = ΔT X / ΔT O ) i (-) = Induction ratio (i = V X / V ZU ) x (m) = horizontal throw y (m) = vertical throw x+y (m) = Horizontal + vertical throw y H (m) = Maximum penetration in heating mode t zu ( C) = Supply air temperature t R ( C) = Room temperature KF (-) = Correction factor L (mm) = Length V X (m³/h) = Total air jet volume at point x V X [l/s] = total air jet volume at point x 04/03-19

Order details Ceiling Slot Diffuser Model DSX without support profile with support profile -P with support profile -PA with support profile -PB Frame profile made of aluminium painted to 9005 (black) Frame profile made of aluminium painted to RAL 9010 (white) Frame profile made of aluminium in natural colour anodised (E6/EV1) Frame profile made of aluminium painted to RAL 9010 (white) Supply air -Z Return air -A Air guide elements made of plastic, similar to RAL colour RAL 9010 (white) -LW Air guide elements made of plastic, similar to RAL colour 9005 (black) -LS Air guide elements made of plastic, similar to RAL colour RAL 9010 (white) -LW Air guide elements made of plastic, similar to RAL colour 9005 (black) -LS I -L I Air guide blade position (air throw pattern) II on the left -L II L II on the right -L II R III -L III 1-slot -1 Number of slots 2-slot -2 3-slot -3 4-slot -4 Length (mm) 500 1000 1500 in band design Please specify the length when ordering. with plenum box without plenum box as dummy piece -BS for operation with overflow air with mounting bracket (pair) -BW Order example: DSX-P1-Z-LS-L III, Length 1000 mm, with plenum box ASK Unless stated otherwise, the thick-frame model will be delivered! 04/03-20

Accessories: Plenum box ASK without damper - with throttle damper -DK without rubber lip seal - with rubber lip seal -GD without insulation - inside -li with insulation external -la without riveting nut - with riveting nut -EM End pieces (a pair) on the left/right (Supplied loose as standard) for DSX-S -ES1 for DSX-P -ES2 for DSX-PB -ES3 made of aluminium painted to made of aluminium painted to made of aluminium natural colour Corner angle 90 (Supplied loose as standard) -EW 04/03-21

Specification texts Ceiling slot diffuser type DSX-S, for supply air, suitable for installation in closed ceiling systems or for concealed installation in the joint of panelled ceilings. Air outflow direction can be adjusted afterwards from below. Noise level and pressure loss remain constant in all air guide blade positions. Slot diffuser consisting of extruded aluminium profile painted in black (RAL 9005) or white (RAL 9010), depending on the colour of the air guide blade. Air guide elements made of plastic, similar to RAL colour 9005 (black, -LS) or 9010 (white, -LW). TÜV inspected according to VDI 6022 Sheets 1+2 as well as DIN 1946 Sheet 2. Product: SCHAKO type DSX-S-Z - Model (number of slots) - Type DSX-S1 (1-slot) - Type DSX-S2 (2-slot) - Type DSX-S3 (3-slot) - Type DSX-S4 (4-slot) - Air guide element position: - L I, vertical throw - L II L, one-way horizontal throw on the left - L II R, one-way horizontal throw on the right - L III, alternate horizontal throw (standard) -Length: - 500 mm - 1000 mm - 1500 mm - in band design with plenum box (-ASK) and concealed mounting (-VM) - Model without plenum box - as dummy piece (-BS) - with M4 riveting nuts - for operation with overflow air with mounting bracket (pair) (-BW) - with M4 riveting nuts - Return air version with air guide elements Product : SCHAKO type DSX-S-A Accessories: - with galvanised sheet steel plenum box (-ASK), and lateral connection spigot and fixing lugs. - with a damper (-DK) in the plenum box adjustable from the front side for air volume regulation. - with rubber lip seal (-GD) - with thermal insulation - internal (-li) - external (-la) - with M4 riveting nuts - with end piece (-ES1, pair) (supplied loose as standard), made of aluminium painted to - RAL 9005 (black) or - RAL 9010 (white) - Corner bracket 90 (-EW) (supplied loose as standard) 04/03-22

Ceiling slot diffuser type DSX-P, for supply air, with support profile for installation in ceiling panels, suitable for installation in closed ceiling systems. Air outflow direction can be adjusted afterwards from below. Noise level and pressure loss remain constant in all air guide blade positions. Slot diffuser made of extruded aluminium profiles in natural colour anodised E6/EV1 or painted to RAL 9010 (white). Air guide elements made of plastic, similar to RAL colour 9005 (black, -LS) or 9010 (white, -LW). TÜV inspected according to VDI 6022 Sheets 1+2 as well as DIN 1946 Sheet 2. Product: SCHAKO type DSX-P-Z - Model (number of slots) - Type DSX-P1 (1-slot) - Type DSX-P2 (2-slot) - Type DSX-P3 (3-slot) - Type DSX-P4 (4-slot) - Air guide element position: - L I, vertical throw - L II L, one-way horizontal throw on the left - L II R, one-way horizontal throw on the right - L III, alternate horizontal throw (standard) -Length: - 500 mm - 1000 mm - 1500 mm - in band design with plenum box (-ASK) and concealed mounting (-VM) - Model without plenum box - as dummy piece (-BS) - with M4 riveting nuts - for operation with overflow air with mounting bracket (pair) (-BW) - with M4 riveting nuts - Return air version with air guide elements Product : SCHAKO type DSX-P-A Accessories: - with galvanised sheet steel plenum box (-ASK), and lateral connection spigot and fixing lugs. - with a damper (-DK) in the plenum box adjustable from the front side for air volume regulation. - with rubber lip seal (-GD) - with thermal insulation - internal (-li) - external (-la) - with M4 riveting nuts - with end piece (-ES2, pair) (supplied loose as standard), made of anodised aluminium in natural colour (E6/EV1) or aluminium painted in white (RAL 9010). - Corner bracket 90 (-EW) (supplied loose as standard) 04/03-23

Ceiling slot diffuser type DSX-PA, for supply air, with support profile for installation in ceiling panels, suitable for installation in closed ceiling systems. Air outflow direction can be adjusted afterwards from below. Noise level and pressure loss remain constant in all air guide blade positions. Slot diffuser made of extruded aluminium profiles in natural colour anodised E6/EV1 or painted to RAL 9010 (white). Air guide elements made of plastic, similar to RAL colour 9005 (black, -LS) or 9010 (white, -LW). TÜV inspected according to VDI 6022 Sheets 1+2 as well as DIN 1946 Sheet 2. Product: SCHAKO type DSX-PA-Z Accessories: - with galvanised sheet steel plenum box (-ASK), and lateral connection spigot and fixing lugs. - with a damper (-DK) in the plenum box adjustable from the front side for air volume regulation. - with rubber lip seal (-GD) - with thermal insulation - internal (-li) - external (-la) - with M4 riveting nuts - Corner bracket 90 (-EW) (supplied loose as standard) - Model (number of slots) - Typ DSX-PA1 (1-slot version) - Typ DSX-PA2 (2-slot version) - Typ DSX-PA3 (3-slot version) - Typ DSX-PA4 (4-slot version) - Air guide element position: - L I, vertical throw - L II L, one-way horizontal throw on the left - L II R, one-way horizontal throw on the right - L III, alternate horizontal throw (standard) - Length: - 500 mm - 1000 mm - 1500 mm - in band design with plenum box (-ASK) and concealed mounting (-VM) - Model without plenum box - as dummy piece (-BS) - with M4 riveting nuts - for operation with overflow air with mounting bracket (pair) (-BW) - with M4 riveting nuts Return air version with air guide elements - Product: SCHAKO type DSX-PA-A 04/03-24

Ceiling slot diffuser type DSX-PB, for supply air, with support profile for installation in ceiling panels, suitable for installation in closed ceiling systems. Air outflow direction can be adjusted afterwards from below. Noise level and pressure loss remain constant in all air guide blade positions. Slot diffuser made of extruded aluminium profiles in natural colour anodised E6/EV1 or painted to RAL 9010 (white). Air guide elements made of plastic, similar to RAL colour 9005 (black, -LS) or RAL 9010 (white, -LW). TÜV inspected according to VDI 6022 Sheets 1+2 as well as DIN 1946 Sheet 2. Product: SCHAKO type DSX-PB-Z - Model (number of slots) - Typ DSX-PB1 (1-slot version) - Typ DSX-PB2 (2-slot version) - Typ DSX-PB3 (3-slot version) - Typ DSX-PB4 (4-slot version) - Air guide element position: - L I, vertical throw - L II L, one-way horizontal throw on the left - L II R, one-way horizontal throw on the right - L III, alternate horizontal throw (standard) -Length: - 500 mm - 1000 mm - 1500 mm - in band design with plenum box (-ASK) and concealed mounting (-VM) - Model without plenum box - as dummy piece (-BS) - with M4 riveting nuts - for operation with overflow air with mounting bracket (pair) (-BW) - with M4 riveting nuts - Return air version with air guide elements Product: SCHAKO type DSX-PB-A Accessories: - with galvanised sheet steel plenum box (-ASK), and lateral connection spigot and fixing lugs. - with a damper (-DK) in the plenum box adjustable from the front side for air volume regulation. - with rubber lip seal (-GD) - with thermal insulation - internal (-li) - external (-la) - with M4 riveting nuts - with end piece (-ES3, pair) (supplied loose as standard), made of anodised aluminium in natural colour (E6/EV1) or aluminium painted in white (RAL 9010). - Corner bracket 90 (-EW) (supplied loose as standard) 04/03-25