MODELS. 2 & 4 Low Profile Linears

Similar documents
MODELS 2 & 4 Top Conduit Linears

MODELS SafeSite LED Linear, Class I Div V, 2 & 4 Versions

FOR USE WITH MODEL NUMBERS:

Operating Instructions

Operating Instructions

SAVE THESE INSTRUCTIONS!!

Operation/Installation Instructions

Operating Instructions

Operating Instructions

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

HAZARDOUS LOCATION STREET LIGHT SLA SERIES INSTALLATION INSTRUCTIONS

SynergEX Panelboards for Hazardous Locations

LAL SERIES LED LUMINAIRE

INSTALLATION INSTRUCTION MANUAL

INSTALLATION INSTRUCTION MANUAL

Installation and Maintenance Manual (2014)

EEQ SERIES COMPACT FLUORESCENT EMERGENCY FACTORY SEALED LIGHTING FIXTURES

IMPORTANT SAFEGUARDS

LED IMPORTANT SAFETY INSTRUCTIONS

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

Installation and Operation Instructions 10/04/13

Installation Documentation ID-2663

Input Voltage: AC: VAC HC: VAC (50/60Hz) Electrical Ratings: WIDE FROSTED MODEL

Installation And Operation Instructions For FHSCP-UNV Series Emergency LED Drivers Models: FHSCP-UNV-5WL, 7.8WL, 10.7WL, 13.

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed

Spun Bay Installation Standard Version (non dimmable), Hook Mount

MaxLite StaxMax LED Flood Lights

GE Lighting. Heavy Industrial High Bay & Low Bay Lighting. (ABR1 - Series) imagination at work

Rental Industry Safety Tester Safe Check 5s

M-3025CB-AV Fuel Pump

MOONRING 1.5 MOONRING 3

VSQ SERIES 30 AMP INTERLOCKED SWITCHED RECEPTACLES

MaxLite LED UTILITY WRAP FIXTURES

CSR COMPACT FUSED INTERLOCKED ARKTITE RECEPTACLE - 30 & 60 AMP Installation & Maintenance Information IF 1440

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST

Installation Instruction ALG Series LED Area Light Version: 3.1

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

60 Watt Industrial LED Low Bay Light

Lumination TM LED Luminaires LAL Series - Continuous Run Option

LED W IMPORTANT: not provide. contact the. fire. LED only. entrap heat. applications. carry high GENERAL: Compare. material.

SBP2 Pendant Pushbutton Stations Installation Instructions

When using electrical equipment, basic safety precautions should always be followed including the following:

Installation Instructions Central Battery Units

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

IMPORTANT SAFETY INSTRUCTIONS

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

LED IMPORTANT SAFETY INSTRUCTIONS

Thermocouple Thermometer Models

ACE Variable Frequency Drive System

L-K INDUSTRIES. Criterion Water Bath

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

SAVE THESE INSTRUCTIONS

Installation Instructions for Appleton Mercmaster LED Luminaire

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

DIESEL EXHAUST FLUID PUMP MOTOR ASSEMBLY REPLACEMENT GUIDE

MaxLite LED Linear HighBay Fixtures

EGT MONITOR AND PROBE KIT BG FUEL SYSTEMS McDonald Road Dahlonega, GA (706) A Edition 03

IsoLED FLEX I CUSTOMER MANUAL

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

ILED Aquarius Illuminated Windsock. User Manual

Instruction/Installation Manual

LED IMPORTANT SAFETY INSTRUCTIONS

VWSQ SERIES 30 AMP INTERLOCKED SWITCH RECEPTACLES

INSTALLATION GUIDE AND USER MANUAL

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES

General Installation Instructions LED

Installation and Maintenance Instructions 44TA Liquid Level Float Switch

Patent Pending. SafeSite LED Linear Fixture - UL 844 for Indoor and Outdoor Hazardous Locations

Switching DC Power Supply

EPLX and D2LX lighting panelboards Installation & maintenance information IF 1813 APPLICATION D2LX/EPLX IF SHEET TABLE OF CONTENTS WEIGHTS

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

CT-930 MANUAL HYDRAULIC COMPRESSION TOOL TABLE OF CONTENTS

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

Installation Instruction

INSTALLATION INSTRUCTIONS

Cordless Sweeper. OWNER S MANUAL Model: CFT Volt DC. Made Exclusively for ALDI Inc. Batavia, IL.,

Captivate Illuminated Mirror Light

INSTALLATION NOTES: nbeckon-26

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

PRO PRO20-115RD 115-Volt AC. PRO Volt AC OWNER'S MANUAL SAVE THESE INSTRUCTIONS

I. Pendant Mount Installation

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

Installation manual. For professional use only

SafeSite LED Based Signaling for Hazardous Locations

General Installation Instructions LED

Martin Screen Vibrators

3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

Installation Instructions

GV-10 Manual 10.5A / 140W IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Solar Charge Controllers with Maximum Power Point Tracking

Barnant Company (Type J) (Type K) (Type T)

Installation Instructions

Schaltgeräte GmbH GmbH Geschäftsbereich Leuchten

INSTALLATION GUIDE AND USER MANUAL

USE AND CARE GUIDE DUALCHECK CIRCUIT TESTER

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Transcription:

INSTALLATION AND MAINTENANCE MANUAL SAFESITE LED LINEAR FIXTURE Document No: 9100-127-2182-99 Rev D December, 2016 MODELS 2 & 4 Low Profile Linears These instructions contain important safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect installation, operation or maintenance 1: Introduction This Linear LED light is designed for illumination of industrial locations. It uses the latest in solid state lighting technology for long life, low maintenance, and high efficiency. The unique optical design focuses light downward to where it is needed, giving improved efficiency over a conventional HID luminaire. An internal, universal input, power-factor-corrected switch-mode supply allows it to be used from any nominal 100V-277V, 50/60Hz AC supply without any variation in light output. Fixtures are SUITABLE FOR WET LOCATIONS in the following locations or unclassified locations (see product label): For Use In: Class I, Division 2, Groups A, B, C, D Class II, Division 2, Groups F, G Class III, Divisions 1 and 2 Ambient Temperature Range: -40C to +65C (T4A) Ambient Temperature Range: -40C to +45C (T5) Note: Save these instructions for future reference.

2: Installation Document No: 9100-127-2182-99 Rev D To avoid the risk of fire, explosion, or electric shock, this product should be installed, inspected, and maintained by a qualified electrician only, in accordance with all applicable electrical codes. To avoid electric shock: Be certain electrical power is OFF before and during installation and maintenance. Luminaire must be connected to a wiring system with an equipment-grounding conductor. To avoid explosion: Make sure the supply voltage is within the luminaries voltage rating. Ensure the marked T Rating is less than the ignition temperature of the Hazardous Atmosphere. Do not operate in ambient temperatures above those indicated on the Luminaire nameplate. Do not operate if the lens is cracked or damaged. All fasteners should be properly seated. WARNING - EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2. AVERTISSEMENT - RISQUE D'EXPLOSION - substitution de composants peut nuire à la conformité Classe I, Division 2. To avoid explosion (Continued): EXPLOSION HAZARD- DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON-HAZARDOUS AVERTISSEMENT - RISQUE D'EXPLOSION - AVANT DE DECONNECTER L'EQUIPEMENT, COUPER LE COURANT OU S'ASSURER QUE L'EMPLACEMENT EST DESIGNE NON DANGEREUX DO NOT let power cord touch hot surfaces DO NOT mount near gas or electric heaters Equipment should be mounted in locations and at heights where it will not be subjected to tampering by unauthorized personnel. The use of accessory equipment not recommend by the manufacture may cause an unsafe condition DO NOT use this equipment for other than it s intended use The technical data indicated on the Luminaire are to be observed. Changes to the design and modifications of the Luminaire are not permitted Only genuine Dialight replacement parts are to be used when unforeseen maintenance is required. Consult factory at www.dialight.com or authorized representative as required. Page 2 of 6

For supply connections use wire rated for at least 90 º C Conduit thru Mount (Figure 2) Installation Steps: Document No: 9100-127-2182-99 Rev D For maximum long term reliability and light output, the light must be installed in free air. o The Linear fixture design incorporates an over-temperature control circuit that reduces input power should internal temperatures reach a maximum level. In this event, light output may be reduced. The Linear fixture is threaded for two 3/4 NPT, at each end, of the Power Supply Housing s Junction Box Sections, in order to be assembled to conduit or with cable. o Remove the 3/4 NPT pipe plugs and attach conduit or cord grips where shown in figure 2. Use conductive pipe sealant for all metal fittings and conduit. Use Teflon tape for polycarbonate 3/4 NPT pipe plugs. o If there is moisture present, or chance of it, in the conduit system then necessary precautions should be taken by the installer to prevent the moisture from entering thru the cable or conduit and entering the fixture. Failure to comply with the above could void factory warranties. o Fixture is factory wired with LINE, NEUTRAL and GROUND leads at each end. Remove the Power Supply Junction Box Cover, which has captive screws, to attach incoming power to the white (Neutral) wire, black (Line) and green (Ground) wire leads with Lever Connectors. Ensure that the o-ring is properly seated in the groove; reattach the Cover. Tighten all screws to 15 in/lbs (1.75NewtonM s) o Restore power and verify operation. Figure 2. TWO 3/4 NPT PORTS AT EACH END JUNCTION BOX COVER WITH CAPTIVE SCREWS AT EACH END Page 3 of 6

Document No: 9100-127-2182-99 Rev D 3: Maintenance To avoid personal injury, disconnect power to the light and allow the unit to cool down before performing maintenance. No user serviceable parts inside of fixture. Risk of electric shock. Removal of the lens will void the warranty. 1) We suggest performing visual, mechanical and electrical inspections on a regular basis. We suggest routine checks to be made on a yearly basis. Frequency of use and environment should determine this. It is recommended to follow an Electrical Preventive Maintenance Program as described in NFPA 70B: Recommended Practice for Electrical Equipment. 2) If the lens (Figure 4 below) requires periodical cleaning to ensure continued photometric performance. Clean the lens with a damp, non-abrasive, lint-free cloth. If not sufficient, use mild soap and water. 3) Inspect the outside of the Luminaire housing to ensure that they are free of any obstructions or contamination (i.e. excessive dust build-up). Clean with a non-abrasive cloth if needed. 4) Do not operate if the lens is cracked or damaged. All fasteners should be properly seated. 5) NOTE: Screws, other than the Junction Box area, are factory torqued and should not be tampered with during installation or maintenance. Figure 3. Polycarbonate Lenses Page 4 of 6

Document No: 9100-127-2182-99 Rev D Nominal AC Supply Voltage Specifications 100-277VAC, 50-60Hz Power consumption: 2 version 33W nominal 4 version 66W nominal Input Current: (Nominal) Operating temperature range.33amps @100Vac (2 foot).66amps @100Vac (4 foot).12amps @277Vac (2 foot).24amps @277Vac (4 foot) -40 F to +149 F [-40 C to +65 C] T4A @ 149 F [65 C] Power factor >0.9 ATHD <20% Dimensions (L x W x H) See Figure 5. -40 F to +113 F [-40 C to +45 C] T5 @ 113 F [45 C] Weight 8 lbs [3.62 kg] (2 ) 11 lbs [4.98 kg] (4 ), Intertek Certified to UL-844, 1598, 1598A, 1012 CSA C22.2 No. 137-M1981 CSA C22.2 No. 250 Figure 4. Page 5 of 6

Document No: 9100-127-2182-99 Rev D Caution (All Models): Chemical Compatibility Guide Footnote on Chemical Compatibility Guide: The chemical compatibility data referenced in the manual was supplied by the raw material manufacturers and is intended as general guide. The data represents the basic material properties and does not necessarily represent the performance of the final product due to manufacturing process and design variations for each final product. Chemical compatibility is highly dependent on concentration, temperature, humidity and other environmental conditions and therefore the customer assumes responsibility for evaluation of gaseous or direct contact chemical compatibility at their site prior to product installation. www.dialight.com/pubs/mdtfchemrflx001.pdf All statements, technical information and recommendations contained herein are based on information and tests we believe to be reliable. The accuracy or completeness thereof is not guaranteed. In accordance with Dialight Corporation Terms and Conditions of Sale, and since conditions of use are outside our control, the purchaser should determine the suitability of the product for his intended use and assumes all risk and liability whatsoever in connection therewith Page 6 of 6