KSOM Control exhaust valve

Similar documents
KTS Supply air valve. Specifications. Quick Selection (50 Pa) Product code example Supply air valve KTS-100-C

KSOF Fire damper valve

STI Supply air valve. Specifications. Quick Selection. Product code example Supply air valve STI-160-C

KTI Supply air valve. Product Facts. Product code example. Quick Selection

OPTIVENT Housing HVSA, HVSL

CTVK Supply air diffuser

Exhaust air diffuser HPKH + Plenum box ATTS

Fire damper ETPR. Specifications. Product code example Fire damper ETPR

KGEB Exhaust valve. Specifications. Quick Selection. Product code example Exhaust valve KGEB-100-C Mounting ring KGEZ-01

Nozzle diffuser DYRH / Supply air unit DYRB (=DYRH+ATTD)

Conical diffuser KHAA TECHNICAL DATA

Supply air unit DYBA. Specifications. Connbox. Quick Selection DYBA, without slot, 1:3 plenum box ATTC (50 Pa)

Supply air diffusers RPPH and ROPH / Supply air units RPPA/ROPA (=RPPH/ROPH+ATTD)

Wall diffuser SVQC / Supply air unit SVQC + ATVA TECHNICAL DATA

Supply air diffusers RHKH and RHOH / Supply air units RHKB/RHOB (=RHKH/RHOH+ATTD)

Fire dampers ETCE and ETCS TECHNICAL DATA

Kitchen exhaust fan GLEB

J L I e x h a u s t h o o d

Zest Iris Duct Dampers

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

ROOFMASTER STEF-HT ROOF FAN

ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE

Exhaust air diffuser EYMA-2 and air intake device DYMA-1

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

ACTIVENT System. Specifications. Product code example ACTA

ROOF FAN ROOFMASTER STEC

THB - Perforated Ceiling Diffuser. Halton THB. Perforated Ceiling Diffuser

ADAPTTM. Free. Active communicative, supply air diffuser for the WISE system, ADAPT F

EXCa. Exhaust register

ADAPTTM. Sphere. Active communicative, supply air diffuser for the WISE system. Quick Selection

ADAPTTM. Extract. Extract air diffuser for the WISE system. Quick Selection

Regulation and shut-off damper SPB and SPC

IQ STAR NOVA II CHILLED BEAM» TECHNICAL DATA

Pressure control damper ERPA

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

CornerAir. CornerAir. Active chilled beam

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser

Long Throw Nozzle WDA

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

ROOFMASTER STEF-HT ROOF FAN

THL - Conical Ceiling Diffuser. Halton THL. Conical Ceiling Diffuser

Room product for Swegon s WISE System for demand-controlled ventilation

CRP. Commissioning damper, Ductwork Leakage Class 0 QUICK FACTS. Perforated damper blade for better damper characteristic

TBV - Terminal Unit. Halton TBV. Terminal Unit

DATASHEET PRODUCT CODE EXAMPLE:

CHILLED BEAM IQ STAR WEGA II

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

DFA - Conical Ceiling Diffuser. Halton DFA. Conical Ceiling Diffuser

BLBd

SILENT MV Ultra Quiet In-line Fans

Adriatic for individually suspended installation Exposed active climate beam with cooling, heating and ventilation

EAGLE Wall. Wall air diffusers with discs for supply air and flush mounting QUICK FACTS

Wall air diffusers with discs for supply air and flush mounting. Quick guide COLIBRI WALL

series RVV Variable flow rate controllers

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Single-inlet centrifugal fans

ROOFMASTER STEF-ATEX ROOF FAN

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

Ultra-quiet circular duct fans TD-SILENT ECOWATT Series

Duct Nozzle Diffuser. L e

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Accessories. Front vane panel Coupling sleeve with gasket Galvanised steel Gasket of rubber compound

ROOFMASTER STEF ROOF FAN

PELICANTM. Wall. Rectangular perforated wall air diffusers for supply air. Quick guide

WGA Long throw nozzle grille

Plenum boxes. About Lindab. Comfort and Design. Product overview / symbols. Theory. Ceiling diffusers. Ceiling diffusers - visible.

Fire Dampers. Types FKA FRL FRK 4/1/EN/1

Differential Pressure Sensors

DKR - Multi-nozzle Ceiling Diffuser. Halton DKR. Multi-nozzle Ceiling Diffuser

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser

CRP. Commissioning damper, Ductwork Leakage Class 0

TRH - Plenum for diffusers. Halton TRH. Plenum for diffusers

Nozzle air diffuser DYSB

HMR DUAL DUCT CABIN UNIT CABIN UNITS HMR. For passenger and crew cabins

Mechanical mixing box MBM

FDCLP2 Constant Volume Series Flow, Low Profile

SINGLE DUCT AIR TERMINAL UNITS

plates and with flexible conduit. Ø Outlet (mm)

TUBUS TUBUS. Key figures. Function Wall-mounted supply air diffusers

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

DKS - Multi-nozzle Ceiling Diffuser. Halton DKS. Multi-nozzle Ceiling Diffuser

RECTANGULAR VAV DAMPER TECHNICAL CATALOGUE

Differential Pressure Sensors

NEW CA MD VENTILATION AIR CONDITIONING AIR CLEANING HEATING ATORTAT. DUISIM DELESTIO COMMOLOBORE

SRY. Ceiling mounted linear disc diffuser for supply air QUICK FACTS

PH SERIES SINGLE DUCT ATU PERFORMANCE DATA

High Performance Fan Coils FCHG Genesis Series Horizontal

Front panel Perforated galvanised steel Stainless steel AISI 316 as option Casing Galvanised steel Stainless steel AISI 316 as option

AHF - Exhaust Grille. Halton AHF. Exhaust Grille

ESAS Smoke control damper

Accessories STRA Room Controller

SINGLE DUCT TERMINAL UNITS

GDD - Supply Grille. Halton GDD. Supply Grille

HFB - Airflow Management Damper HFB. Airflow Management Damper. Product models and Accessories

GRD PRODUCT CATALOG DISPLACEMENT VENTILATION PRODUCTS

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

Ceiling swirl diffusers

Acoustic Twin Fans (ATQ)

Transcription:

KSOM Control exhaust valve KSOM is ideal for rooms which require forced exhaust air flow. KSOM consists of exhaust valve, control motor and controller card, which are installed in the valve cone. KSOM has an integrated humidity sensor which controls the valve. The valve is perfect for use for example in the bathrooms of single family homes, terraced houses and apartment blocks. Using various control units, air flow can be controlled to suit the needs of different rooms and changing operating conditions. Quick Selection Specifications Exhaust valve with control motor and controller card. Includes also a humidity sensor. Operates within a wide pressure and air flow range. Low noise level. Airflow easily measured and controlled. Augmentation time can be set steplessly for anywhere between 15 minutes to 2 hours. Suitable for new construction and renovation installation. Manufactured of steel sheet. Product code example Exhaust air valve KSOM-100 1 (6) Specifications are subject of alteration without further notice.

Dimensioning Selection diagrams KSOM-100 Selection KSOM is selected on the basis of the desired basic air flow rate, forced air flow rate and noise level. The used air flow can be adjusted steplessly by turning the screw spindle of the motor. The valve must however be selected so that the basic adjustment position can be set at -15-0 mm to enable a sufficient forced effect. Selection example Bathroom ventilation according to part D2 of the Finnish Code of Building Regulations. KSOM-125 Normal exhaust 8 l/s and forced exhaust 15 l/s. The pressure drop of the air terminal device is defined (e.g. 50 Pa). A suitable air terminal device size is chosen (Ø100). The normal exhaust adjustment is -10 and the desired forcing is achieved at position 0. The pressure drop from the ducts increases during forced exhaust, in which case the proportion of the total pressure drop to be used by the valve decreases. The forced exhaust position is set at 10 mm (increases the air flow from 8 l/s of the normal exhaust to 15 l/s of the forced exhaust) The desired forced exhaust is achieved with the choice of pressure level and forced exhaust position: 5, 10, 15 or 20 mm. (See selection diagrams). Ventilation system The room-specific forced exhaust achieved with KSOM valve can be realized according to two principles depending on the ventilation system. The valves can be used as a part of a constant pressure system, in which case the forced exhaust is achieved by increasing the total air flow. When the constant pressure maintaining is not used, the forced exhaust is achieved by loaning from other rooms. 2 (6) Specifications are subject of alteration without further notice.

Sound data Sound power level Lw Correction K oct (db) KSOM Middle frequency by octave band (Hz) 63 125 250 500 1000 2000 4000 8000 100 2-6 -5 0-2 -1-9 -16 125 1 2-3 -1-4 1-11 -19 Tol.± 6 3 2 2 2 2 2 3 Dimensions and weights KSOM Sound power levels by octave bands are obtained by adding to the total sound pressure level L p10a, db(a), the corrections K oct presented in the table according to the following formula: L Woct = L p10a + K oct Correction K oct is an average value in the range of use of the KSOM. Sound attenuation ΔL Sound attenuation ΔL (db) KSOM Middle frequency by octave band (Hz) 63 125 250 500 1000 2000 4000 8000 100 25 20 13 9 10 11 6 7 125 21 16 12 10 9 14 6 6 Tol.± 6 3 2 2 2 2 2 3 Size D (mm) d (mm) H (mm) A (mm) Weight (kg) 100 135 87 89 105 0.63 125 161 107.5 105 105 0.76 Extension ring Average sound attenuation ΔL from duct to room including the end reflection of the connecting duct in wall installation. Definitions q v air flow (l/s) Δp t total pressure drop (Pa) L p10a sound pressure level with 4 db room attenuation (10 m 2 sab) [db(a)] L Woct sound power level (db) K oct correction (db) ΔL sound attenuation from duct to room (db) Frame Size ØA (mm) Ød (mm) 100 151 103 125 181 128 Size ØA (mm) Ød (mm) 100 99.3 98 125 124.3 123 3 (6) Specifications are subject of alteration without further notice.

Installation and connecting The mounting frame delivered with the product is fitted to the duct with rivets. The valve is rotated into the frame. Detailed instructions in the installation and connecting manual delivered with the product. The control exhaust valve is delivered with a fixedly installed 1 m cable. This requires placing the connecting box close enough to the valve. The frame / extension ring has a hole for the wire. In concealed mounting, a protecting tube must be brought from the connecting box to the valve (Fig. 1) to enable the drawing of the cable delivered with the valve to the box. It is not allowed to change the cable delivered with the valve, but it can be extended with a cable satisfying the requirements. Measurement and regulation of air flow The air flow is measured by a pressure difference measurement with a separate measuring tube. The air flow is regulated by changing the positions. The measuring diagrams and detailed regulation instructions can be found in the installation and connecting instructions delivered with the product. 4 (6) Specifications are subject of alteration without further notice.

Wiring diagrams KSOM Controlled with a humidity sensor integrated in the valve KSOM Controlled with an external switch Accessories and technical data of actuator Accessories Manual operating switch Strömfors Artic PS1 Manual operating switch with timer Strömfors ATC 10 A Occupancy sensor (wall) Calectro PIR-TF-25 - mounting base for ceiling MB-95 - mounting base for wall MB-98 Occupancy sensor (ceiling) Calectro PIR-TF-25-360 Humidity controller - electronic E + E Elektronics EE14 - mechanical Industrie Technik DBZH Choosing transformer The KSOM valves operate on a voltage of 24 VAC. The transformer size is chosen according to the overall power demand of the devices connected to it. The power demand of one valve is 500 ma / 12 VA. The choice of transformer type is also affected by the placing of the valve and the conditions in its surroundings. A transformer for one valve is available at FläktGroup, see product code. Technical data of the actuator Supply voltage 24 V AC (protective extra low voltage, SELV) ± 20 % Rated power 12 VA / 500 ma Controlling With a closing switch Running time Max. 6 s Noise level while running 38 db(a) Electric protection III (protective extra low voltage, PELV) Enclosure IP00 Ambient temperature + 10 C... + 50 C Storage temperature - 25 C... + 65 C Humidity... 100 % Electromagnetic compatibility 89/336/EY Safety 98/37/EY Service Follow separate manual Calculated life 100 000 cycles 5 (6) Specifications are subject of alteration without further notice.

Application, function, construction, product code Application KSOM is ideal for rooms which require forced exhausts. The valve can be opened electrically according to operating conditions (with a manual switch or an occupancy or humidity sensor) It is available in sizes Ø100 and Ø125. An extension ring enables surface and concealed mounting for electrical connections. Product code and accessories Product code Control exhaust valve Control exhaust valve, special colour (mounting ring included) Size (aaa) 100, 125 KSOM-aaa KSOM-aaa-E Function The basic adjustment of KSOM can be set steplessly when balancing the ducting. The forced exhaust can be set from the controller at 5, 10, 15 or 20 mm (pre-set by the factory at 10 mm). KSOM has an integrated humidity sensor which controls the valve (forced exhaust RH 65% and return RH 60%). As well as with an integrated sensor, KSOM can also be controlled externally (e.g. with an operating switch). The integrated sensor can also be disabled with the control switch, enabling only external control. KSOM controlling with a room-specific controller: see accessories. In addition, the valve performs an automatic test run every day, irrespective of whether forced ventilation is needed or not. The valve motor operates with a voltage of 24 VAC. Construction KSOM consists of exhaust valve, control motor and controller card, which are installed in the valve cone. The valve disc contains a control motor with a screw spindle and a controller, with which the disc can be run into the open position. In addition, a plastic tube which prevents the cover from rotating during forced exhaust has been attached to the disc. The delivery includes a valve with connecting cable, mounting ring and extension ring, with which a free space can be reserved for the connecting cable between the wall or ceiling surface and the frame. Material The valve is made of steel sheet and it is powder coated in white. Other colours are available on request. The valve body is equipped with a cellular plastic sealing gasket. The mounting ring is made of steel sheet. The airtight mounting ring KKT includes a Veloduct rubber sealing gasket and a wire inlet equipped with an inlet rubber gasket. Descriptive text Control exhaust valve KSOM, valve for external control, e.g. KSOM-100 manufactured by FläktGroup. Accessories Transformer 24 V / 0,5 A KSOZ-8 6 (6) Specifications are subject of alteration without further notice.