Series Diesel Generator Set 1 of 12 INCLUDES: Two Line LCD Multilingual Digital Evolution Controller (English/Spanish/ French/Portuguese) with external viewing window for easy indication of generator status and breaker position. Isochronous Electronic Governor Sound ttenuated luminum Enclosure Smart attery Charger UV / Ozone Resistant Hoses ±1% Voltage Regulation Five Year Limited Warranty Not for sale in US/C Standby Power Rating Model RD015-15 kw 60 Hz Model RD020-20 kw 60 Hz Model RD030-30 kw 60 Hz Model RD048-48 kw 60 Hz (single phase only) Model RD050-50 kw 60 Hz (three phase only) *ssembled in the US using domestic and foreign parts FETURES INNOVTIVE DESIGN & PROTOE TESTING are key components of GENERC'S success in IMPROVING POWER Y DESIGN. ut it doesn't stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CS, NEM, EGS, and other standards, allows you to choose GENERC POWER SYSTEMS with the confidence that these systems will provide superior performance. TEST CRITERI: PROTOE TESTED SYSTEM TORSIONLTESTED NEM MG1-22 EVLUTION MOTOR STRTING ILITY TRUE POWER ELECTRICL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro-chip based appliances, such as variable speed HVC systems. SOLID-STTE, FREQUENCY COMPENSTED VOLTGE REGULTION: This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FST RESPONSE to changing load conditions and MXIMUM MOTOR STRTING CPILITY by electronically torque-matching the surge loads to the engine. Digital voltage regulation at ±1%. SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. GENERC TRNSFER SWITCHES: Long life and reliability are synonymous with GENERC POWER SYSTEMS. One reason for this confidence is that the GENERC product line includes its own transfer systems and controls for total system compatibility.
2 of 12 15 20 30 48 50 kw application and engineering data GENERTOR SPECIFICTIONS Type Synchronous Rotor Insulation Class H (15 & 20 kw) or F (30, 48, & 50 kw) Stator Insulation Class H Telephone Interference Factor (TIF) <50 lternator Output Leads 1-Phase Three wire lternator Output Leads 3-Phase Six wire earings Single Sealed Cartridge Coupling Direct, Flexible Disc Excitation System Direct Total Harmonic Distortion < 5% VOLTGE REGULTION Type Electronic Sensing Single Phase Regulation ± 1% Features djustable Voltage & Gain GOVERNOR SPECIFICTIONS Type Electronic Isochronous Steady State Regulation ± 0.25% ELECTRICL SYSTEM attery Charge lternator Static attery Charger Recommended attery (battery not included) System Voltage 50 mp (15 & 20 kw), 65 mp (30 kw), or 70 mp (48 & 50 kw) 2 mp Group 27F, 700CC* *Group 31, 925CC batteries can also be used with the 30kW 12 Volts LTERNTOR SPECIFICTIONS Revolving field heavy duty generator Directly connected to the engine Operating temperature rise 120 C above a 40 C ambient Class H insulation is NEM rated Class F insulation is NEM rated ll models fully prototype tested ENCLOSURE FETURES luminum weather protective enclosure Enclosed critical grade muffler Small, compact, attractive SE Ensures protection against mother nature. Electrostatically applied textured epoxy paint for added durability. Quiet, critical grade muffler is mounted inside the unit to prevent injuries and maximize sound dampening. Makes for an easy, eye appealing installation. Sound attenuated enclosure ensures quiet operation.
15 20 30 48 50 kw application and engineering data ENGINE SPECIFICTIONS: 15 & 20 KW Make Mitsubishi Model Cylinders 4 In-line Displacement (Liters) 2.505 ore (in / mm) 3.46 / 88 Stroke (in / mm) 4.06 / 103 Compression Ratio 22:1 Intake ir System Cylinder Head Type Piston Type Naturally spirated Cast Iron OHV luminum FUEL SYSTEM Fuel Type Fuel Pump Type Injector Type Fuel Supply Line (mm / in) Fuel Return Line (mm / in) Fuel Specification Fuel Filtering (microns) Ultra Low Sulfur Diesel Fuel Mechanical Engine Driven Gear Mechanical 7.94 / 0.31 (ID) N/ - 15 & 20 kw 4.76 / 0.19 (ID) - 30 kw 7.94 / 7 (ID) - 48 & 50 kw STM 6-15 & 20 kw 25-30 kw 10-48 & 50 kw 3 of 12 ENGINE SPECIFICTIONS: 30 KW Make Model Cylinders 4 Perkins In-line Displacement (Liters) 2.216 ore (in / mm) 3.30 / 84 Stroke (in / mm) 3.94 / 100 Compression Ratio 23.3:1 Intake ir System Cylinder Head Type Piston Type Turbocharged / ftercooled Cast Iron OHV luminum ENGINE SPECIFICTIONS: 48 & 50 KW Make Generac Model Cylinders 4 In-line Displacement (Liters) 3.4 ore (in / mm) 3.86 / 98 Stroke (in / mm) 4.45 / 113 Compression Ratio 18.5:1 Intake ir System Cylinder Head Type Piston Type ENGINE LURICTION SYSTEM Oil Pump Type Oil Filter Type Crankcase Capacity (quarts / liters) Turbocharged / ftercooled Cast Iron OHV luminum Gear Full flow spin-on canister 6.87 / 6.5-15 & 20 kw 11.2 / 10.6-30 kw 7.4 / 7 48 & 50 kw ENGINE COOLING SYSTEM Water Pump Fan Speed (rpm) Fan Diameter (in / mm) Fan Mode TNK SPECIFICTIONS Total Size (gallons/liters) Usable Size (gallons/liters) Run Time @ 1/2 Load (hrs) Pre-lubed, self-sealing 2376-15 & 20 kw 1980-30 kw 2029-48 & 50 kw 18.11 / 460 (15 & 20 kw) 18 / 457.2 (30 kw) 22 / 559 (48 & 50 kw) Pusher 45 / 170.3-15 & 20 kw 68 / 257.4-30, 48, & 50 kw 40 / 151.4-15 & 20 kw 61 / 230.9-30, 48, & 50 kw 48.7-15 kw 38.8-20 kw 44.5-30 kw 26.5-48 & 50 kw WEIGHTS ND DIMENSIONS Model Weight (lb / kg) Dimensions (L x W x H) (in / cm) 15 kw 1372 / 622 62 x 31 x 49 / 158 x 78 x 124 20 kw 1372 / 622 62 x 31 x 49 / 158 x 78 x 124 30 kw 1726 / 783 77 x 35 x 57 / 195 x 89 x 147 48 & 50 kw 1953 / 886 77 x 35 x 55 / 195 x 89 x 141
4 of 12 15 20 30 48 50 kw application and engineering data GENERTOR OUTPUT VOLTGE / KW 60 HZ RD015 RD020 RD030 RD048 RD050 kw (standby) mp (standby) kw (Prime) mp (Prime) C Size 120/240 V, 1Ø, 1.0 pf 15 62 12 50 70 120/208 V, 3Ø, 0.8 pf 15 52 12 42 60 120/240 V, 3Ø, 0.8 pf 15 45 12 36 50 120/240 V, 1Ø, 1.0 pf 20 83 16 67 100 120/208 V, 3Ø, 0.8 pf 20 69 16 56 80 120/240 V, 3Ø, 0.8 pf 20 60 16 48 70 120/240 V, 1Ø, 1.0 pf 30 125 24 100 150 120/208 V, 3Ø, 0.8 pf 30 104 24 83 125 120/240 V, 3Ø, 0.8 pf 30 90 24 72 100 277/480 V, 3Ø, 0.8 pf 30 45 24 36 50 120/240 V, 1Ø, 1.0 pf 48 200 38.4 183 200 120/208 V, 3Ø, 0.8 pf 50 173 40 153 200 120/240 V, 3Ø, 0.8 pf 50 150 40 132 175 277/480 V, 3Ø, 0.8 pf 50 75 40 66 90 SURGE CPCITY IN MPS Voltage Dip @ < 0.4 pf 15% 30% 120/240 V, 1Ø 53 129 RD015 120/208 V, 3Ø 37 90 120/240 V, 3Ø 32 78 120/240 V, 1Ø 87 211 RD020 120/208 V, 3Ø 59 143 120/240 V, 3Ø 51 124 120/240 V, 1Ø 66 168 RD030 120/208 V, 3Ø 59 144 120/240 V, 3Ø 51 125 277/480 V, 3Ø 26 64 RD048 RD050 120/240 V, 1Ø 69 189 120/208 V, 3Ø 90 218 120/240 V, 3Ø 78 189 277/480 V, 3Ø 36 87 ENGINE FUEL CONSUMPTION gal/hr L/hr 25% of rated load 0.60 2.27 RD015 50% of rated load 0.85 3.22 75% of rated load 1.10 4.16 100% of rated load 1.46 5.53 25% of rated load 0.77 2.9 RD020 50% of rated load 1.03 3.90 75% of rated load 1.46 5.53 100% of rated load 1.97 7.46 25% of rated load 0.97 3.67 RD030 50% of rated load 1.37 5.19 75% of rated load 1.97 7.46 100% of rated load 2.77 10.49 RD048 RD050 25% of rated load 1.35 5.11 50% of rated load 2.15 8.14 75% of rated load 3.06 11.58 100% of rated load 3.98 15.07
15 20 30 48 50 kw operating data ENGINE COOLING 15 kw 20 kw 30 kw 48 & 50 kw ir flow (inlet air including alternator and combustion air in cfm/cmm) 2750 / 78 2750 / 78 2800 / 79 2824 / 80 System coolant capacity (gal/liters) 3.0 / 11.4 3.0 / 11.4 2.5 / 9.5 2.8 / 10.6 Heat rejection to coolant (TU per hr/mj per hr) 95,220 / 100.5 95,220 / 100.5 128,638 / 135.7 135,900 / 143.4 Maximum operation air temperature on radiator ( C/ F) 50 / 122 Maximum ambient temperature ( C/ F) 50 / 122 5 of 12 COMUSTION REQUIREMENTS Flow at rated power (cfm / cmm) 86.3 / 2.4 86.3 / 2.4 88 / 2.5 190 / 5.38 SOUND EMISSIONS Sound output in d() at 23 ft (7 m) with generator in exercise mode* 65 Sound output in d() at 23 ft (7 m) with generator operating at normal load* 70 EXHUST Exhaust flow at rated output (cfm/cmm) 98.88 / 2.8 98.88 / 2.8 296.6 / 8.4 448 / 12.7 Exhaust temperature at rated output ( C/ F) 482 / 900 482 / 900 499 / 930 604.4 / 1120 ENGINE PRMETERS Rated Synchronous RPM 1800 HP at rated kw 26.4 33.5 49 85 POWER DJUSTMENT FOR MIENT CONDITIONS Temperature Deration...3% for every 5 C above 25 C or 1.7% for every 5 F above 77 F ltitude Deration (15, 30, 48 & 50 kw)...1% for every 100 m above 915 m or 3% for every 1000 ft above 3000 ft ltitude Deration (20 kw)...1% for every 100 m above 305 m or 3% for every 1000 ft above 1000 ft CONTROLLER FETURES 2-Line Plain Text Multilingual LCD Display... Simple user interface for ease of operation. Mode uttons: uto...utomatic Start on Utility failure. Programmable 7 day exerciser. Manual... Start with starter control, unit stays on. If utility fails, transfer to load takes place. Off... Stops unit. Power is removed. Control and charger still operate. Ready to Run/Maintenance Message.... Standard Engine Run Hours Indication... Standard Programmable start delay between 2-1500 seconds... Five seconds standard (programmable by dealer only) Utility Voltage Loss/Return to Utility djustable... From 140-171 V/190-216 V Future Set Capable Exerciser/Exercise Set Error Warning... Standard Run/larm/Maintenance Logs... 50 Events Each Engine Start Sequence... Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration) Starter Lock-out... Starter cannot re-engage until 5 seconds after engine has stopped. Smart attery Charger... Standard Charger Fault/Missing C Warning... Standard Low attery/attery Problem Protection and attery Condition Indication... Standard utomatic Voltage Regulation with Over and Under Voltage Protection... Standard Under-Frequency/Overload/Stepper Overcurrent Protection... Standard Safety Fused/Fuse Problem Protection... Standard utomatic Low Oil Pressure Shutdown... Standard Overcrank/Overspeed (@ 72 Hz)/RPM Sense Loss Shutdown... Standard High Engine Temperature Shutdown... Standard Internal Fault/Incorrect Wiring Protection... Standard Common External Fault Capability... Standard Field Upgradeable Firmware... Standard Low Coolant Level Shutdown... Standard uxiliary Shutdown... Standard
D2.5L G2 Single Wall (1 of 2) 6 of 12 SCLE 0.050 WT-KG SEE OVE SHEET 1 of 2 4 3 2 1 SH REV WINDCHILL VERSION 4 3 1/2.4 1 SERVICE ITEM 2.5L WEIGHT DT WITH EMPTY SETNK NOTES: (SEE NOTE 5) 739 [29.1] OIL FILL CP RIGHT SIDE CENTER OF GRVITY GENERTOR S SHOWN 622 [1372] 1. MINIMUM RECOMMENDED CONCRETE PD SIZE: 1092 (43") WIDE X 1887 (74.3") LONG. OIL DIP STICK RIGHT SIDE REFERENCE INSTLLTION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PD GUIDELINES. OIL FILTER RIGHT SIDE WITH WOODEN SHIPPING SKID 661 [1457] 2. LLOW SUFFICIENT ROOM ON LL SIDES OF THE GENERTOR FOR MINTENNCE OIL DRIN HOSE LEFT SIDE ND SERVICING. THIS UNIT MUST E INSTLLED IN CCORDNCE WITH CURRENT WEIGHT: KG [LS] RDITOR/EXHUST IR INTKE PPLICLE NFP 37 ND NFP 70 STNDRDS S WELL S NY OTHER FEDERL, RDITOR DRIN HOSE LEFT SIDE DIMENSIONS: MM [INCH] DISCHRGE IR (OTH SIDES) STTE, ND LOCL CODES. (OTH SIDES) COOLNT RECOVERY OTTLE LEFT SIDE 3. CONTROL PNEL / CIRCUIT REKER INFORMTION: RDITOR FILL CP CCESS ROOF - SEE SPECIFICTION SHEET OR OWNERS MNUL RDITOR/EXHUST - CCESSILE THROUGH CUSTOMER CCESS SSEMLY DOOR ON RER OF GENERTOR. DISCHRGE IR IR CLENER ELEMENT LEFT SIDE 4. REMOVE THE RER STU-UP ND RER ENCLOSURE COVER PNEL TO CCESS MUFFLER FRONT THE STU-UP RES S FOLLOWS: FN ELT EITHER SIDE - HIGH VOLTGE CONNECTION INCLUDING C LOD LED CONDUIT CONNECTION, NEUTRL CONNECTION, ND TTERY CHRGER 120 VOLT C (0.5 MP MX) CONNECTION. TTERY LEFT SIDE 2" O.D. - LOW VOLTGE CONNECTION INCLUDING TRNSFER SWITCH CONTROL WIRES EXHUST ND CCESSORY RELY CONNECTION (QTY 4) OUTLET REFERENCE OWNERS MNUL FOR PERIODIC 5. CENTER OF GRVITY ND WEIGHT MY CHNGE DUE TO UNIT OPTIONS. REPLCEMENT PRT LISTINGS 6. OTTOM OF GENERTOR SET MUST E ENCLOSED TO PREVENT PEST INTRUSION ND RECIRCULTION OF DISCHRGE IR ND/OR IMPROPER COOLING IR FLOW. 7. REFERENCE OWNERS MNUL FOR LIFTING WRNINGS. 8. MOUNTING OLTS OR STUDS TO MOUNTING SURFCE SHLL E 5/8-11 GRDE 5 212 [8.4] (USE STNDRD SE TORQUE SPECS) 9. MUST LLOW FREE FLOW OF INTKE IR, DISCHRGE IR ND EXHUST. SEE SPEC SHEET FOR MINIMUM IR FLOW ND MXIMUM RESTRICTION REQUIREMENTS. 110 [4.3] REMOVE COVER FOR TTERY 12 VOLT 10. GENERTOR MUST E INSTLLED SUCH THT FRESH COOLING IR IS VILLE CCESS TO RDITOR NEGTIVE GROUND ND THT DISCHRGE IR FROM RDITOR IS NOT RECIRCULTED. FILL CP TOP VIEW ENCLOSURE PNEL MUST E VISE CTION LTCH, 631 [24.8] ONE PER DOOR, ONE RDITOR/EXHUST REMOVED TO FCILITTE DOOR LIFT-OFF DOOR PER DISCHRGE IR TTERY INSTLLTION ND RER ENCLOSURE REMOVL SIDE OF GENERTOR COVER PNEL CUSTOMER CCESS SSEMLY, CONTROL PNEL CCESS, TTERY CHRGER LOCTED WITHIN 1238 [48.7] OPEN PUNCHED LOUVERS ICL OVERLL ON OTH SIDES OF FUEL TNK HEIGHT CIRCUIT REKER VENTILTION DUCT TO PROVIDE SEE NOTE 3 DEQUTE CROSS-FLOW OF IR VENTILTION 303 [11.9] EXHUST MUFFLER REMOVLE ENCLOSED WITHIN STU-UP COVER GENERTOR ENCLOSURE 182 1065 [41.9] 776 [30.6] [7.2] LEFT SIDE VIEW OVERLL WIDTH 1582 [62.3] OVERLL LENGTH LIFTING PROVISION (4 PLCES) RER VIEW SEE NOTES 5, 7 ND CENTER OF GRVITY DIMENSIONS RIGHT SIDE VIEW TITLE INSTLL PROTECTOR D2.5L G2 SINGLE WLL TNK DRWING CRETED FROM PRO/ENGINEER 3D FILE. ECO MODIFICTION TO E PPLIED TO SOLID MODEL ONLY. GENERC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRWING WHICH IS SUPPLIED IN CONFIDENCE ND MUST NOT E USED FOR NY PURPOSE OTHER THN FOR WHICH IT IS SUPPLIED WITHOUT THE EXPRESS WRITTEN CONSENT OF GENERC POWER SYSTEMS. c GENERC POWER SYSTEMS 2013 ISSUE DTE: 06/2017 SIZE CGE NO DWG NO N/ 10000022175 REV ELECTRONICLLY PPROVED INSIDE WINDCHILL 15 20 kw installation layout
15 20 kw installation layout D2.5L G2 Single Wall (2 of 2) SH REV WINDCHILL VERSION 4 3 2/2.4 1 FUEL FILL (2" NPT FEMLE) 1120 [44.1] FUEL LEVEL 1008 [39.7] GUGE/SENDER 787 [31.0] EMERGENCY VENT 691 [27.2] (2" NPT FEMLE) NORML VENT (2" NPT FEMLE) SCLE 0.080 WT-KG SEE OVE SHEET 2 of 2 4 3 2 1 7 of 12 446 [17.5] FUEL TNK TOTL CPCITY 169 [44] USLE CPCITY 151 [40] HIGH ND LOW CPCITY: LITER [GLLON] VOLTGE 674 [26.5] DIMENSIONS: MM [INCH] STU-UP RE 625 [24.6] *NOTE: STU-UP RE FOR HIGH 105 [4.1] ND LOW VOLTGE CONNECTIONS, *STU-UP CIRCUIT REKER, NEUTRL ND RE CUSTOMER CONNECTION OPENING. 151 [5.9] FUEL SUPPLY 9 51 [.4] 851 [33.5] 40 [1.6] [2.0] 100 [3.9] *STU-UP 1347 [53.0] 224 RE [8.8] TOP VIEW 738 [29.1] REMOVLE STU-UP COVER REMOVLE COVER 251 [9.9] 354 [13.9] 16.66 [0.66] FUEL TNK MOUNTING HOLES HEIGHT (6 PLCES) SEE NOTE 8 112 [4.4] 19 739 [29.1] 792 [31.2] [.7] MOUNTING CENTERS 1472 [57.9] 776 [30.6] 1584 [62.4] RER VIEW LEFT SIDE VIEW TITLE INSTLL PROTECTOR D2.5L G2 SINGLE WLL TNK DRWING CRETED FROM PRO/ENGINEER 3D FILE. ECO MODIFICTION TO E PPLIED TO SOLID MODEL ONLY. GENERC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRWING WHICH IS SUPPLIED IN CONFIDENCE ND MUST NOT E USED FOR NY PURPOSE OTHER THN FOR WHICH IT IS SUPPLIED WITHOUT THE EXPRESS WRITTEN CONSENT OF GENERC POWER SYSTEMS. c GENERC POWER SYSTEMS 2013 ISSUE DTE: 06/2017 SIZE CGE NO DWG NO N/ 10000022175 REV ELECTRONICLLY PPROVED INSIDE WINDCHILL
30 kw installation layout D2.2L G22 Single Wall (1 of 2) 8 of 12 SH REV WINDCHILL VERSION 4 3 1/2.4 1 SERVICE ITEM 2.2L WEIGHT DT WITH EMPTY SETNK NOTES: OIL FILL CP RIGHT SIDE (SEE NOTE 5) 874 [34.4] CENTER OF GRVITY OIL DIP STICK RIGHT SIDE GENERTOR S SHOWN 783 [1726] 1. MINIMUM RECOMMENDED CONCRETE PD SIZE: 1194 (47") WIDE X 2261 (89") LONG. REFERENCE INSTLLTION GUIDE SUPPLIED WITH UNIT OIL FILTER RIGHT SIDE WITH WOODEN SHIPPING SKID 819 [1806] FOR CONCRETE PD GUIDELINES RDITOR/EXHUST OIL DRIN HOSE RIGHT SIDE DISCHRGE IR WEIGHT: KG [LS] 2. LLOW SUFFICIENT ROOM ON LL SIDES OF THE GENERTOR FOR MINTENNCE IR INTKE RDITOR DRIN HOSE LEFT SIDE (OTH SIDES) DIMENSIONS: MM [INCH] ND SERVICING. THIS UNIT MUST E INSTLLED IN CCORDNCE WITH CURRENT PPLICLE NFP 37 ND NFP 70 STNDRDS S WELL S NY OTHER FEDERL, (OTH SIDES) COOLNT RECOVERY OTTLE LEFT SIDE STTE, ND LOCL CODES. RDITOR FILL CP CCESS ROOF 3. CONTROL PNEL / CIRCUIT REKER INFORMTION: IR CLENER ELEMENT RIGHT SIDE - SEE SPECIFICTION SHEET OR OWNERS MNUL - CCESSILE THROUGH CUSTOMER CCESS SSEMLY DOOR ON RER OF MUFFLER FRONT SIDE GENERTOR FN ELT EITHER SIDE 4. REMOVE THE RER TNK ND RER ENCLOSURE COVER PNEL TO CCESS TTERY LEFT SIDE THE STU-UP RES S FOLLOWS: - HIGH VOLTGE CONNECTION INCLUDING C LOD LED CONDUIT CONNECTION REFERENCE OWNERS MNUL FOR NEUTRL CONNECTION, TTERY CHRGER 120 VOLT C (0.5 MP MX) CONNECTION. PERIODIC REPLCEMENT PRT LISTINGS - LOW VOLTGE CONNECTIONS INCLUDING TRNSFER SWITCH CONTROL WIRES 5. CENTER OF GRVITY ND WEIGHT MY CHNGE DUE TO UNIT OPTIONS. 6. ENGINE SERVICE CONNECTIONS 173 [6.8] OIL DRIN: 3/8" NPT EXHUST EXHUST OUTLET: 2" O.D. OUTLET 7. OTTOM OF GENERTOR SET MUST E ENCLOSED TO PREVENT PEST INTRUSION ND ND RECIRCULTION OF DISCHRGE IR ND/OR IMPROPER COOLING IR FLOW. 8. REFERENCE OWNERS MNUL FOR LIFTING WRNINGS. 9. MOUNTING OLTS OR STUDS TO CONCRETE PD SHLL E 5/8-11 GRDE 5 146 [5.8] TTERY 12 VOLT REMOVE COVER FOR (USE STNDRD SE TORQUE SPECS) EXHUST NEGTIVE GROUND CCESS TO RDITOR OUTLET FILL CP SCLE 0.050 WT-KG SEE OVE SHEET 1 of 2 4 3 2 1 TOP VIEW RDITOR/EXHUST DISCHRGE IR 897 [35.3] VISE CTION LTCH, ONE PER DOOR WIDTH DOOR, ONE LIFT-OFF DOOR RER ENCLOSURE PER SIDE OF GENERTOR COVER PNEL CUSTOMER CCESS SSEMLY, CONTROL PNEL CCESS, TTERY CHRGER LOCTED WITHIN, OPEN PUNCHED LOUVERS ICL ON OTH SIDES OF FUEL TNK VENTILTION 1452 [57.2] DUCT TO PROVIDE DEQUTE OVERLL CROSS-FLOW OF IR HEIGHT CIRCUIT REKER VENTILTION SEE NOTE 3 EXHUST MUFFLER 324 [12.7] ENCLOSED WITHIN GENERTOR ENCLOSURE REMOVLE STU-UP COVER 182 [7.2] 1322 [52.0] 888 [35.0] OVERLL WIDTH 1954 [76.9] OVERLL LENGTH LIFTING PROVISION (4 PLCES) LEFT SIDE VIEW RER VIEW SEE NOTES 5, 8 ND CENTER RIGHT SIDE VIEW OF GRVITY DIMENSIONS TITLE INSTLL PROTECTOR D2.2L G22 SINGLE WLL TNK DRWING CRETED FROM PRO/ENGINEER 3D FILE. ECO MODIFICTION TO E PPLIED TO SOLID MODEL ONLY. GENERC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRWING WHICH IS SUPPLIED IN CONFIDENCE ND MUST NOT E USED FOR NY PURPOSE OTHER THN FOR WHICH IT IS SUPPLIED WITHOUT THE EXPRESS WRITTEN CONSENT OF GENERC POWER SYSTEMS. c GENERC POWER SYSTEMS 2013 ISSUE DTE: 07/2017 SIZE CGE NO DWG NO N/ 10000018294 REV ELECTRONICLLY PPROVED INSIDE WINDCHILL
30 kw installation layout D2.2L G22 Single Wall (2 of 2) SH REV WINDCHILL VERSION 4 3 2/2.4 1 1196 [47.1] 1045 [41.2] 4 3 2 1 9 of 12 926 [36.5] FUEL FILL 844 [33.2] (2" NPT FEMLE) FUEL SUPPLY FUEL LEVEL FUEL RETURN GUGE/SENDER FUEL TNK TOTL CPCITY 253.6 [67] USLE CPCITY 230.9 [61] CPCITY: LITER [GLLONS] HIGH ND LOW DIMENSIONS: MM [INCH] VOLTGE STU-UP 757 [29.8] RE 786 [30.9] *NOTE: STU-UP RE FOR HIGH ND LOW VOLTGE CONNECTIONS, 621 [24.5] 125 [4.9] CIRCUIT REKER, NEUTRL ND STU-UP CUSTOMER CONNECTION OPENING. RE 267 [10.5] 181 [7.1] NORML VENT 38 (2" NPT FEMLE) 51 [1.5] 1430 [56.3] [2.0] EMERGENCY VENT (2" NPT FEMLE) 1555 [61.2] 62 [2.5] 125 [4.9] STU-UP 1690 [66.5] 253 RE [10.0] TOP VIEW 850 [33.5] REMOVLE REMOVLE COVER STU-UP COVER 397 [15.6] 16.7 [0.66] 250 [9.9] MOUNTING HOLES FUEL TNK (8 PLCES) SEE HEIGHT NOTE 9 19 [.7] 851 [33.5] 112 [4.4] MOUNTING CENTERS 712 [28.0] 888 [35.0] 1242 [48.9] RER VIEW 1842 [72.5] 1954 [76.9] LEFT SIDE VIEW TITLE INSTLL PROTECTOR D2.2L G22 SINGLE WLL TNK DRWING CRETED FROM PRO/ENGINEER 3D FILE. ECO MODIFICTION TO E PPLIED TO SOLID MODEL ONLY. ISSUE DTE: 07/2017 GENERC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRWING WHICH IS SUPPLIED IN CONFIDENCE ND MUST NOT E USED FOR NY PURPOSE OTHER THN FOR WHICH IT IS SUPPLIED WITHOUT THE EXPRESS WRITTEN CONSENT OF GENERC POWER SYSTEMS. c GENERC POWER SYSTEMS 2013 SIZE CGE NO N/ REV DWG NO 10000018294 REV SCLE 0.075 WT-KG SEE OVE SHEET 2 2 of ELECTRONICLLY PPROVED INSIDE WINDCHILL
D3.4L Single Wall (1 of 2) 10 of 12 WEIGHT DT WITH EMPTY SETNK NOTES: (SEE NOTE 5) 1. MINIMUM RECOMMENDED CONCRETE PD SIZE: 1194 (47") WIDE X 2261 GENERTOR S SHOWN (STEEL ENCL) 886 [1953] (89") LONG. REFERENCE INSTLLTION GUIDE SUPPLIED WITH UNIT WITH WOODEN SHIPPING SKID 925 [2039] FOR CONCRETE PD GUIDELINES 2. LLOW SUFFICIENT ROOM ON LL SIDES OF THE GENERTOR FOR MINTENNCE ND SERVICING. THIS UNIT MUST E INSTLLED IN CCORDNCE WITH CURRENT PPLICLE NFP 37 ND NFP 70 STNDRDS S WELL S NY OTHER FEDERL, STTE ND LOCL CODES. 3. CONTROL PNEL / CIRCUIT REKER INFORMTION: - SEE SPECIFICTION SHEET OR OWNERS MNUEL - CCESSILE THROUGH CUSTOMER CCESS SSEMLY DOOR ON RER OF GENERTOR 4. REMOVE THE RER TNK ND RER ENCLOSURE COVER PNEL TO CCESS THE STU-UP RES S FOLLOWS: -HIGH VOLTGE CONNECTION INCLUDING C LOD LED CONDUIT CONNECTION NEUTRL CONNECTION, TTERY CHRGER 120 VOLT C (0.5 MP MX) CONNECTION. -LOW VOLTGE CONNECTIONS INCLUDE TRNSFER SWITCH CONTROL WIRES 5. CENTER OF GRVITY ND WEIGHT MY CHNGE DUE TO UNIT OPTIONS. 6. ENGINE SERVICE CONNECTIONS OIL DRIN: 3/8" NPT EXHUST OUTLET: 2" O.D. 7. OTTOM OF GENERTOR SET MUST E ENCLOSED TO PREVENT PEST INTRUSION ND RECIRCULTION OF DISCHRGE IR ND/OR IMPROPER COOLING IR FLOW. 8. EXHUST SYSTEM MXIMUM CK PRESSURE: 35 INCHES H20. 9. REFERNCE OWNERS MNUL FOR LIFTING WRNINGS. 10. MOUNTING OLTS OR STUDS TO CONCRETE PD SHLL E 5/8-11 GRDE 5 UNITS: WEIGHT - KG [LS] DIMENSION - MM [INCH] 302 [11.9] 888 [35.0] 182 1322 [52.0] OVERLL WIDTH [7.2] 1954 [76.9] OVERLL LENGTH 173 [6.8] RIGHT SIDE VIEW RDITOR/EXHUST DISCHRGE IR (OTH SIDES) 146 [5.8] RDITOR/EXHUST DISCHRGE IR 758 [29.8] DOOR FRONT TNK COVER SERVICE ITEM 3.4L OIL FILL CP RIGHT SIDE OIL DIP STICK RIGHT SIDE OIL FILTER RIGHT SIDE OIL DRIN HOSE RIGHT SIDE RDITOR DRIN HOSE LEFT SIDE IR CLENER ELEMENT RIGHT SIDE MUFFLER FRONT FN ELT EITHER SIDE TTERY LEFT SIDE INSTLL CPL PROT D3.4L SW EXHUST MUFFLER ENCLOSED WITHIN GENERTOR ENCLOSURE GENERC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRWING WHICH IS SUPPLIED IN CONFIDENCE ND MUST NOT E USED FOR NY PURPOSE OTHER THN FOR WHICH IT IS SUPPLIED WITHOUT THE EXPRESS WRITTEN CONSENT OF GENERC POWER SYSTEMS. c GENERC POWER SYSTEMS 2013 0K6968 REFERENCE OWNERS MNUL FOR PERIODIC REPLCEMENT PRT LISTINGS. TOP VIEW RER VIEW LEFT SIDE VIEW RER ENCLOSURE COVER PNEL CIRCUIT REKER SEE NOTE 3 CUSTOMER CCESS SSEMLY, CONTROL PNEL 1408 CCESS, TTERY CHRGER [55.4] LOCTED WITHIN OVERLL HEIGHT RER TNK COVER VISE CTION LTCH, ONE PER DOOR, ONE LIFT-OFF DOOR PER SIDE OF GENERTOR LIFTING PROVISIONS (4 PLCES) SEE NOTE 10 ND CENTER OF GRVITY DIMENSIONS REMOVE COVER FOR CCESS TO RDITOR FILL CP 48 50 kw installation layout 892 [35.1] CENTER OF GRVITY SEE NOTE 5 IR INTKE (OTH SIDES) TTERY 12 VOLT NEGTIVE GROUND
48 50 kw installation layout D3.4L Single Wall (2 of 2) 11 of 12 1688 [66.4] 786 [30.9] 125 [4.9] *STU-UP RE 253 [10.0] 76 [3.0] 112 [4.4] *STU-UP RE 757 [29.8] 621 [24.5] 267 [10.5] 181 [7.1] 1194 [47.0] 1044 [41.1] 923 [36.4] 828 [32.6] FUEL RETURN FUEL SUPPLY 1431 [56.3] 1554 [61.2] 51 [2.0] 38 [1.5] 112 [4.4] 712 [28.0] 1242 [48.9] FUEL TNK TOTL CPCITY 253.6 [67] USLE CPCITY 230.9 [61] 1842 [72.5] INNER TNK NORML VENT (2" NPT FEMLE) REMOVLE COVER 1954 [76.9] CPCITY: LITER [GLLONS] DIMENSIONS: MM [INCH] *NOTE: STU-UP RE FOR HIGH ND LOW VOLTGE CONNECTIONS, CIRCUIT REKER, NEUTRL ND CUSTOMER CONNECTION OPENING. REMOVLE STU-UP COVER 353 [13.9] 851 [33.5] 888 [35.0] INSTLL CPL PROT D3.4L SW GENERC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRWING WHICH IS SUPPLIED IN CONFIDENCE ND MUST NOT E USED FOR NY PURPOSE OTHER THN FOR WHICH IT IS SUPPLIED WITHOUT THE EXPRESS WRITTEN CONSENT OF GENERC POWER SYSTEMS. c GENERC POWER SYSTEMS 2013 0K6968 INNER TNK EMERGENCY VENT (2" NPT FEMLE) HIGH ND LOW VOLTGE STU-UP FUEL FILL (2" NPT FEMLE) FUEL LEVEL GUGE/SENDER 16.7 [.66] MOUNTING HOLES (8 PLCES)
15 20 30 48 50 kw available accessories MODEL # PRODUCT DESCRIPTION 12 of 12 G006505-0 - 15 & 20 kw G006506-0 - 30, 48, & 50 kw Tank Risers G006512-0 Lockable Fuel Cap Tank risers are required in some municipalities to help avoid potential base tank corrosion caused by mounting on rough surfaces. The cast iron, lockable fuel cap provides the ability to lock the fuel system to prevent unwanted fuel tampering or fuel siphoning. G007640-0 - 15 & 20 kw G007641-0 - 30 kw G006570-0 - 48 & 50 kw Maintenance Kits The Protector Maintenance Kits offer all the hardware necessary to perform complete maintenance on Ottomotores Protector generators. G007650-0 - 15 & 20 kw G007651-0 - 30 kw G006558-0 - 48 & 50 kw Cold Weather Kits Recommended for generators installed in regions where the temperature regularly falls below 32 F (0 C). The Cold Weather Kits consist of a block heater with all necessary mounting hardware and a battery warmer with a thermostat built into the battery wrap. G005703-0 Paint Kit If the generator enclosure is scratched or damaged, it is important to touch up the paint to protect from future corrosion. The paint kit includes the necessary paint to properly maintain or touch up a generator enclosure. G006873-0 Smart Management Module (50 mps) Manage large loads by utilizing up to 8 individual Smart Management Modules. These devices are installed directly in line with existing appliance wiring for easy installation. Generac Power Systems, Inc. S45 W29290 HWY. 59, Waukesha, WI 53189 generac.com 2018 Generac Power Systems, Inc. ll rights reserved. ll specifications are subject to change without notice. Part No. 10000023918 rev C (08/13/18)