FS2 Valves. Solenoid Powered to Close / Auto Reset Butterfly Valves

Similar documents
FS3 Valves. Solenoid Powered to Open / Spring to Close (failsafe)

E-M Series. Combined Manual and Automatic Engine Overspeed Shut Down Valves

E Series. Automatic Engine Overspeed Shut Down Valves

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Stop Types)

SVX-Series Solenoid Actuated Diesel Air Shut Down Valves

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run Types for Non-Hazardous Areas)

SELECTION, APPLICATION AND MAINTENANCE

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run, Hazardous Area Types without Manual Override)

Solenoid Actuated Diesel Engine Air Shut Down Valves

SELECTION, APPLICATION AND MAINTENANCE

D-Series Automatic Engine Overspeed Shut Down Valves (Bendix Types)

Diesel Engine Shutdown Valve

MVX-Series Diesel Engine Air Shut Down Valves

Diesel Engine Shutdown System

D-Series Automatic Engine Overspeed Shut Down Valves (Bendix Types)

E1186X Breather Kit. For Yanmar L48N Engines

SVX-Series Diesel Engine Shut Down Valves (Solenoid Latched Types with Manual Start Override/Emergency Stop)

Diesel Engine Shutdown Valves

HVX-Series Diesel Engine Shut Down Valves (Oil Pressure Latched Types with Manual Start Override/Emergency Stop)

MPX-Series Diesel Engine Shut Down Valves (Manual Reset / Air Pressure and Manual Closure Options)

D200 Spindle Type Automatic Engine Overspeed Air Intake Shut Down Valve (including Manual, Oil and Air Pressure Shut Down Control options)

Automatic Fuel Shut Down Valves

SELECTION, APPLICATION AND MAINTENANCE

D-Series Automatic Engine Overspeed Shut Down Valves (Mini Range)

Oil Seal Catalogue. Ashley Power Ltd Ashley Road Parkstone Poole Dorset, BH14 0AQ. P1

Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black

World class manufacturer of safety solutions SYSTEM SELECTION GUIDE. Safety solutions for vehicles and machines working in petrochemical plants

RODADEACO. Diesel Engine Air Intake Shutoff Valves. Model RDB3 Compact Butterfly Valve. by AMOT. Overview. Typical Applications

SERIES 2000 GAS SAFETY SHUT OFF VALVE

by AMOT World class diesel engine safety solutions Product Selection Guide

Black Teknigas. Powerseat Eco Gas Safety Shut-Off Valve. Technical, Installation and Maintenance Details. WattsIndustries.co.uk

Diesel Engine Air Intake Shutoff Valves

Quarter turn actuators Index

ATB Series - Integral Throttle Body Actuators

PH2 POWERHALT AIR INTAKE SHUT-OFF VALVE C50201A ½ DODGE 6.7L CUMMINS C50202A DODGE 6.

PRECISION UK Ltd DUPLEX AGSS PLANT

PH2 C50219A AIR INTAKE SHUT-OFF VALVE. T800 KENWORTH / ISX ENGINE WITH POWERGUARD SMART OVERSPEED LIMITER

TECHNICAL MANUAL OPERATOR S, UNIT, INTERMEDIATE (DS) AND INTERMEDIATE (GS) MAINTENANCE MANUAL FOR

Locktite Manual Reset Gas Shut-Off Valves

1000 Series 1004G Diesel Engine ElectropaK Belt-Driven Coolant Pump

PSM72H Push-Button Start Module

LCL FILTERS INSTRUCTIONS MANUAL (M A) (c) CIRCUTOR S.A.

3 Edition Product brochure GB AGA

System Selection Guide

KTA50 Land Based Drilling Power Modules

, /2 Soft start ( soft clutch ) valve

PH1 AIR INTAKE EMERGENCY SHUT-OFF VALVE PULL CABLE ACTUATION.

Self-Exciting Flameproof Alternator

LNG Screw Down Non-Return Valve Installation, Operation and Maintenance Manual

Flameproof Alternator

Engine Emission Control 6.7L Diesel

Customized Solutions. Safety & Reliability Stainless steel 316 products

pneumatic function fittings

SB-E ISS.05. Operation Manual AA4400A Automatic Air Assisted Airless Spray Gun

Engine Power Output Low

Ratings TAG2A (1500 rpm)...1: TAG2A (1800 rpm)...1: TAG3A (1500 rpm)...1: TAG3A (1800 rpm)...

AIR INTAKE EMERGENCY SHUT-OFF VALVE C50203 AIR INTAKE SHUT-OFF VALVES APPLICATION DODGE 5.9L CUMMINS.

@Perkins. Technical Data Series 2806A-E18TAG1A. Basic technical data. Cyclic irregularity for engine/flywheel maximum: Ratings.

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS

TAG2A TAG3A. Series kwm 1500/1800 rpm kwm 1500/1800 rpm ElectropaK. Ratings. Basic technical data

Contents. Overview. Safety Instructions. Before Installation. Installation. Operation. Maintenance. Replacement Parts. System Specifications 8 01


Flameproof Alternator

AIR INTAKE EMERGENCY SHUT-OFF VALVE PH2 C50204 AIR INTAKE SHUT-OFF VALVE DODGE 6.7L CUMMINS.

@Perkins. Technical Data Series 2806C-E18TAG1A. Diesel Engine - ElectropaK. Basic technical data. Cyclic irregularity. Ratings.

512 HO M285 Engine (FrechW) Maybach Engine M285

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Microprocessor Controlled Dental Vacuum System Installation Manual

PH2 AIR INTAKE EMERGENCY SHUT-OFF VALVES. APPLICATION C ½ DODGE 6.7L CUMMINS C DODGE 6.

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

ACHL Series Pump. Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

abc CPD7948/075 Rotors, rotor shafts and rotor casings are coated with an anti-corrosive and anti wear coating to prolong element life and efficiency.

Intake Air Shut-off Valve

Flameproof Alternator

IOM IR-110-X. Solenoid Control Valve

Spare Parts List. EW-3500-C and D EW-4200-C and D Marine Diesel Generators

2015 PSI 8.8L LPG Engine Overview. Study Guide. Course Code: 8777

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

Solenoid interlock AZM 200 The non-contact interlock.

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

Solenoid valves VUVS/valve manifold VTUS, NPT

Section 10 Chapter 17

Oregon Fuel Injection

CUP ACCESSORIES SECTION 4 FLOW VALVES, CHECK VALVES, MECHANICAL VALVES, SWIVEL JOINTS, & TEE ADAPTORS EDCO USA.

Preventive maintenance 4

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

TC Series Cooling Systems

DEEP SEA ELECTRONICS PLC

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

LIMIT SWITCHES & POSITION INDICATION

TAG1A TAG2A. Series kwm 1500 rpm kwm 1500 rpm ElectropaK. Basic technical data.

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

DEEP SEA ELECTRONICS PLC

1 of :23

100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE

VE4000 & VE5000 SERIES

Transcription:

FS2 Valves Solenoid Powered to Close / Auto Reset Butterfly Valves Part of the F Series of easily installed, compact, air intake valves for diesel engine emergency shut down.

Application The FS2 version of the Wyndham Page F Series of engine air intake closure valves is designed to be installed in the air intake system of a diesel engine to provide an emergency means of rapid shut down when triggered by a 12 or 24 volt signal. This signal may be generated automatically by engine overspeed or any other selected fault conditions and /or applied via a manual emergency stop button. Once the FS2 valve has operated to stop the engine the valve will automatically reset to the open [engine run] state as soon as the shut down signal is no longer applied. The low intake air flow restriction through the open valve makes it generally compatible with the requirements of low emission diesel engines. Corrosion resistant materials are used where applicable in the construction of the valve. This lightweight and compact valve design together with the availability of factory fitted hose adaptors selected from a wide range of optional sizes assists in easy installation. The valve may be fitted to either turbocharged or naturally aspirated engines. In the case of turbocharged engines temperature limitations may restrict the position in which the valve may be installed in the intake system. Note. Wyndham Page also supply speed switches for incorporation into the emergency shut down control circuit of this type of application. Please contact Wyndham Page or your Wyndham Page supplier for details. 2

Description and Main Dimensions Versions of the FS2 valve can be selected to operate by either a 12 volt or 24 volt shut down signal. Once the input shut down signal is removed the valve always automatically resets to the open status. In standard form the FS2 valve is available complete with formed hose adaptors as selected by the customer from a range of standard sizes see diagram below and data on pages 4 and 5. Where a requirement exists for a non-standard adaptor size or other alternative form of intake pipe connection such as bolted joint, please pass details of requirement to Wyndham Page or your Wyndham Page supplier for investigation. Optionally the valve can be supplied fitted with an internal microswitch to indicate the open / closed status of the valve. The valve has a metal to metal seal when closed. It is designed for low closing friction and long life of the sealing surfaces. The latching / release mechanism is configured to withstand high shock loads without malfunction. The electrical enclosure is to IP66. The diagram below and the diagrams and data on pages 4 to 6 cover the main features and basic dimensions of the FS2 range including selection of options and order coding. LABEL: AIRFLOW ARROW SAFETY NOTICE HOSE ADAPTOR CABLES SOLENOID & MICROSWITCH (IF FITTED) LABEL: SERIAL No PART No RATING 3

METRIC TABLE DIMENSIONS (MM) H TO SUIT HOSE BORE MODEL BORE A B C D E 38 1.47 038 44 1.47 044 51 1.47 051 57 81 131 50 20 57 1.46 057 64 1.46 064 70 1.51 070 FS2 E WEIGHT KG D E B A VALVE BORE H HOSE ADAPTOR 30 (42) ORDER CODE 76 1.44 076 83 1.53 083 71 99 149 28 25 89 1.60 089 95 1.68 095 102 1.77 102 108 1.85 108 95 125 175 35 25 114 1.94 114 121 2.05 121 127 2.24 127 133 2.34 133 120 154 204 42 25 140 2.47 140 146 2.58 146 152 3.04 152 159 3.18 159 165 145 185 236 49 25 3.30 165 171 3.44 171 178 3.61 178 203 192 238 291 65 40 5.69 203 21 (27) 100 (110) 4 45 71 (77) ( ) = APPLIES TO 203 VALVE C

IMPERIAL TABLE DIMENSIONS (INCHES) H TO SUIT HOSE BORE MODEL BORE A B C D E 1.50 3.24 038 1.73 3.24 044 2.01 3.24 051 2.2 3.18 5.14 1.97 0.79 2.24 3.22 057 2.52 3.22 064 2.76 3.33 070 FS2 WEIGHT LB ORDER CODE 2.99 3.18 076 3.27 3.37 083 2.80 3.90 5.87 1.10 0.98 3.50 3.53 089 3.74 3.70 095 4.02 3.90 102 4.25 4.08 108 3.74 4.92 6.89 1.38 0.98 4.49 4.28 114 4.76 4.52 121 5.00 4.94 127 5.24 5.16 133 4.72 6.06 8.03 1.65 0.98 5.51 5.45 140 5.75 5.69 146 5.98 6.70 152 6.26 7.01 159 6.50 5.71 7.28 9.29 1.93 0.98 7.28 165 6.73 7.59 171 7.01 7.96 178 7.99 7.56 9.37 11.46 2.56 1.57 12.55 203 5

Valve Selection To enable Wyndham Page to select the most suitable version of the FS2 valve for the Customers application the following data is required: [1]. Bore size of the intake hose into which the intake valve is to be fitted - refer to section headed Installation [mechanical]. [2]. Whether a 12 volt or 24 volt shut down signal is to be used. [3]. Whether a built in microswitch is required. Order Coding FS2 - XXX - XX - M - S000 Special features code (refer to sales) Microswitch option: M Voltage: 12 or 24 Adaptor size (order code in table) Special Features: By arrangement with Wyndham Page. 6

Installation [mechanical] Select a position for the valve which meets the requirements below and also permits a suitable run for the connected electrical cables. Ensure direction of the engine intake airflow complies with that marked on the valve. If an engine air intake system flametrap is also fitted, the shut down valve must be installed upstream (air cleaner side) of the flametrap. The valve may be fitted in any attitude from horizontal to vertical but not in a position where it is subjected to temperatures, internal or external, outside of the range -40C to +120C. Additionally in the case of naturally aspirated engines fit the valve as close as possible to the intake manifold. For turbocharged engines fit the valve upstream of the turbocharger except where an air charge cooler is fitted in which case it may be fitted downstream of the charge cooler subject to not exceeding the +120C limit. Do not fit valve between the turbocharger and charge cooler. The hose and associated intake system into which the valve is installed should be adequate to fully support the valve whilst not permitting excessive vibration of the valve. Generally ensure that there is sufficient flexibility in the finalised intake system to allow for the necessary relative movement between the intake system components over the full range of engine operating conditions to avoid excessive mechanical stresses. Any existing crankcase breather arrangement venting directly into the engine intake ports or into the intake system downstream of the FS2 valve, must be sealed and replaced by a crankcase breather arrangement connected into the intake system upstream of the FS2 valve or, if permitted at the operating site, vented to atmosphere. Important Note. Retain the standard fuel shut down stop fitted to the engine. The Wyndham Page FS2 air intake valve is designed for emergency stop only. 7

Installation [electrical] The wiring diagrams show the connections for the valve solenoid and, where applicable, the optional microswitch. The electrical data for the solenoid and microswitch is tabulated on page 9. It is recommended that a manual switch for emergency stop is always incorporated. Important notes. [1]. Design of the electrical shut down system must take into account the limitations applicable in terms of applying power to the solenoid [see solenoid electrical specification on page 9]. This restriction must also be applied where a manual shut down switch is also incorporated in the electrical shut down circuit. [2]. It is recommended that for additional safety when a manual shut down switch is incorporated it should be directly supplied at the correct voltage from source and not via the shut down control circuit. FS2 VALVE SCHEMATIC: FS2 VALVE SCHEMATIC: Microswitch Version 8

General and Electrical Specification GENERAL DESCRIPTION: A slim butterfly valve designed for emergency shutoff of the engine air intake. Operating mode: Spring open, energise to close. Duel coil solenoid. GENERAL SPECIFICATION: Temperature: Max ambient: 120 C Max intake air temp: 120 C Construction: Body and disk: Hard anodized aluminium Other main components: Stainless steel, aluminium Hose adaptors: Aluminium ELECTRICAL SPECIFICATION: Energise pull coil to close, energise hold coil to hold valve in closed position after engine stop if required. 12 or 24 volt option specified when ordering Solenoid rating: 12 Volt: Pull Coil - 46A, Hold Coil - 1.1A 24 Volt: Pull Coil - 25A, Hold Coil - 0.5A Pull coil max single pulse: 1.5 seconds Max 4 cycles in one minute Recommended engine controller setting: 1 second pull MICROSWITCH OPTION: S.P.D.T - 24V, 10A Max MICROSWITCH CABLE: SIHF silicone insulated multicore cable: Standard length 3m 9

Operation The FS2 valve is always held in the open [engine run] state except whilst a shut down signal at the specified voltage is applied. This signal causes the solenoid within the valve to rotate the valve disc from the run position to the stop position thereby shutting down the engine. The FS2 valve has no manual reset facility. It can only be operated by the application or removal of an electrical signal at the appropriate voltage. Where fitted the valves internal microswitch permits an indication of the valves open / closed status. 10

Maintenance The following maintenance schedule should be undertaken. Subject to experience of local operating conditions the frequency of the maintenance schedule may be varied. Carry out the proposed maintenance work when the equipment is in a safe area and record details of the work carried out. Rectify any problems identified before returning the diesel powered equipment back into service. FOLLOWING INITIAL INSTALLATION AND THEREAFTER AT WEEKLY INTERVALS: [1]. Check all intake pipework between the FS2 valve and engine intake manifold to ensure all pipe fittings and any support brackets are properly fitted and secure and that the engine intake is leak free and shows no sign of significant deterioration or damage. [2]. Start engine. Carry out a shut down using the stop signal from the shut down control system. Check that the valve snaps shut and brings the engine to a stop within a few seconds. SIX MONTHLY: Remove the FS2 valve. Wipe clean as necessary and visually inspect for damage or excessive wear. Bench test valve function. Refit and complete the Weekly maintenance as listed above. 11

Unit 1c Chalwyn Industrial Estate, Parkstone, Poole, Dorset BH12 4PE United Kingdom Tel: +44 (0)1202 734 656 Email: sales@wyndhampage.com www.wyndhampage.com 12 FS2 Valve Handbook-V1.1