AIRCLEAN 32 USER MANUAL. High-pressure cleaner. Wilhelmsen Ships Service. Produced in Norway for:

Similar documents
DP3 Pump. 3:1, Air-operated, Oil. General. Operation. Technical Data. Installation R0 10/09. 35a 35b 35c

Service Handbook. High-Pressure Washer Pump

Service Handbook HD /97

DP5 Pump. 5:1, Air-operated, Heavy Duty, Oil. General. Operation. Technical Data. Installation R1 09/10

RCV-125 REMOTE CONTROL SYSTEM IMPORTANT WARNING FOR SAFER BLAST CLEANING

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

ATD-8400 BENCH TOP BLAST CABINET OWNER S MANUAL

Inverted High Pressure Fluid Filters

PACKING, HANDLING, TRANSPORTING AND STORING MOTORS

LEAK TEST PROCEDURE DC CHANNEL LIFTERS SINGLE VACUUM SYSTEMS TESTING AND MAINTENANCE MUST BE DONE BY A QUALIFIED PERSON KEEP FOR FUTURE REFERENCE

Instruction Manual. Maple 7/15 Pump. Model

ABSC-1028 Blast Machine - 18 ltr.

EP1306N 5 Gallon Can Extruder System Rev. A June EP1306N Operation Manual

Parking brake Mechanical brake acting on rear wheels

Multi-Spray Unit Air-Assisted Airless Spray Unit MSU-111N (13:1 Stand Mount) MSU-113N (13:1 Cart Mount) MSU-114N (13:1 Wall Mount)

ATD-6810 SPRAY GUN W/CUP INSTRUCTION MANUAL

EQUALIZER International Limited 10T(I) Integral Hydraulic Spreading Wedge Repair Instruction Manual

40041 Heavy Duty ADA System with Booster Bracket for JK Heavy Duty ADA System with Booster Bracket for 2012 to Current JK

High Pressure Abrasive Blast Cabinet 42000

Air Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013.

Paint/Solvent/Dump Valve and Flow-Through Valve

SERVICE PARTS LIST SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 13 HP DIRECT DRIVE PRESSURE WASHER CATALOG NO

Models GP7645GB-180/ GP7655GB-180. Gearbox Versions for Pinion Shaft Drives

PRODUCT OPERATING MANUAL

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

OWNER S MANUAL. ROTARY SURFACE CLEANER Models 105C, 105F, 105CW, & 105FW. Revision 2.01

DISPLACEMENT PUMP INSTRUCTIONS-PARTS LIST Rev. K. Model , Series A Model , Series B Model , Series A

Fast-Flo Pump INSTRUCTIONS-PARTS LIST. Table of Contents 1:1 RATIO

Air Operated Grease Ratio Pumps 50:1 BGRP

HD 1050 DE. Maximum performance. Optimum ease of use. Maximum independence. Outstanding mobility

OWNER S MANUAL. Power-Injection-Gun PIG

Foam Equipment & Accessories

PETROL DRIVEN POWER WASHER

SHOT BLAST CABINET MODEL No. CSB20B Part No OPERATING & MAINTENANCE INSTRUCTIONS

DP556 Pump. 55:1, Air-operated, Grease. General. Operation. Technical Data. Installation. Mounting with Reinforced Cover (Recommended)

Instructions Parts List

Polypropylene Piston Drum Pumps

HD 9/23 De. Maximum independence. Highly versatile. Optimum ease of use. For the toughest jobs

Model 8329 Table of Contents

EVAC Commercial Marine Equipment TOILET TECHNICAL DATA EVAC 90, STAINLESS STEEL, FLOOR MODEL, *SHOCK TESTED. Fresh water.

#9040 FUEL TANK SWEEPER

HDS 5/11 U. Fine-mesh water filter. Efficiently protects high-pressure pump against contamination. Easy to remove from outside.

SAFETY MANUAL READ FIRST!

TOYOTA 4RUNNER COLD AIR INTAKE FJ CRUISER Preparation

Model GP Triplex Ceramic Plunger Pump Operating Instructions/ Manual

BRAKE SYSTEM Return To Main Table of Contents

SAI GM Series Piston Hydraulic Motor Crankshaft Design Radial Piston Motors

DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING VACUUM PUMPS

JM-2900 Gas Jet Operating Instructions

RB15 KNAPSACK SPRAYER

Installation Instructions

LEAK TEST PROCEDURE MRT4-DC LIFTERS SINGLE VACUUM SYSTEMS TESTING AND MAINTENANCE MUST BE DONE BY A QUALIFIED PERSON KEEP FOR FUTURE REFERENCE

ENGINE LUBRICATION & COOLING SYSTEMS SECTIONLC CONTENTS. ENGINE LUBRICATION SYSTEM...2 Precautions...2

Operation, Installation, Maintenance and Repair Guide. HighFlo (HF) Control Handle. SERVICE BULLETIN SB 3097 Rev. A 6/14

General safety notes

OPERATION & MAINTENANCE INSTRUCTIONS

1/2" AIR DRIVEN DIAPHRAGM PUMP

GENERAL WARNING. General instructions. Technical assistance. Doseuro S.r.l. Liability

Models GP7545GB-180/ GP7555GB-180. Gearbox Versions for Pinion Shaft Drives

DIAPHRAGM PUMPS: Instruction Manual

6L Oil-less Air Compressor 53103

MACH 1A HVLP (MACH 1AV HVLP) Automatic Airspray Gun

50 Gallon Skid Sprayer

PIT CLEANING SYSTEM PIT CLEANER ASSEMBLY: RC

HDS 7/10-4 M. Medium class hot water high-pressure cleaner with a host of user-friendly features. Efficiency. Operational reliability

50:1 Grease Pump Kits

8 PARTS MANUAL 8.1 LIFT ASSEMBLY

WARNING Carefully Read These Instructions Before Use

HOSES. nozzle BRASS QUICK SEWER NOZZLE TAPE WASHER HIGH PRESSURE HOSE TOOLS TURBO HIGHER PSI RATING. o rings WASH SOAP CHISELING FLUSHING BLASTING

USE and MAINTENANCE INSTRUCTION MANUAL AZ3 HTE2 AZ3 HTE2 HVLP GRAVITY. SPRAY GUN Series. en it fr es pt de se

18 KG MOBILE SODA BLASTING UNIT

HDS 5/15 UX. Integrated hose reel. Water fine filter. Innovative upright design. Compact design

3000 PSI GASOLINE HIGH PRESSURE WASHER

150 Gallon 3- Point Hitch Sprayer

Model Table of Contents. SERVICE & OPERATING MANUAL Original Instructions. Instructions Sheet:

Oregon Fuel Injection

HYDRAULICS. TX420 & & lower. Hydraulic Tandem Pump Removal. 4. Remove the LH side panel (Fig. 0388).

Owner's Manual. Model: LS-PCO-100-GEM ( ) (100 Gallon Skid-Mounted High Pressure Sprayer) Technical Specifications. General Information

HDS 5/11 U EASY! Innovative upright design. Fine-mesh water filter. Compact design. Stainless steel heating coil

ASSEMBLY MANUAL SMC 2491 LOADER VALVE AND PLUMBING KIT INSTRUCTIONS KUBOTA TRACTORS

Common Rail Injector

Installation & Operator s Manual

Single shot MODEL EGA700 OWNERS MANUAL

Models GP5132, GP5136, GP5142 & GP5145. Triplex Ceramic Plunger Pump Operating Instructions / Manual

MAINTENANCE DESCRIPTION. Specifications Information and Repair Parts Manual &

HDS 5/12 C. Economical. Storage. Ease of use. Mobility

HDS 5/11 U. Innovative upright design. Fine-mesh water filter. Compact design. Stainless steel heating coil

Model No. SP Low Volume Low Pressure (LVLP) Gravity Feed Spray Gun

Pump Operating and Maintenance Manual - Models

ADDITIONAL DOCUMENTATIONS FOR PUMPS, MODEL F and FT

Water Broom. Instruction manual ESPAÑOL: PÁGINA 7 FRANÇAIS : PAGE 13 MODEL PCA270

LEAK TEST PROCEDURE APPLICABLE TO DC3 INTELLI-GRIP LIFTERS MODELS MRT4-DC3, MRTA8-DC3, MRTALP8-DC3 AND PC/P1-DC3 SERIES

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V 3800V 3900V

Sewer cleaning & sewer cleaning nozzles 08

Operating and Maintenance Manual

Page 1 of 19. Part# /10/2006

ENGLISH POSEIDON 7 - C3 SERVICE MANUAL

ABSC-2452 Blast Machine ltr.

85 C HD 7/16-4 ST-H. Adaptation according to requirements thanks to retrofitting capability. Individual configurability saves investment costs

Installation & Operator s Manual

Transcription:

AIRCLEAN 32 High-pressure cleaner USER MANUAL Produced in Norway for: Wilhelmsen Ships Service

Contents E.1 IMPORTANT INFORMATION 3 E.1.1 Safety 3 E.1.2 Lubrication 3 E.1.3 Air operating pressure 3 E.1.4 Frost protection 3 E.1.5 Guarantee 3 E.2 DESCRIPTION AND OPERATION 4 E.2.1 Pump unit 4 E.2.2 Water inlet 4 E.2.3 Air inlet 4 E.2.4 Chemical dosing 4 E.2.5 Cleaning procedures 4 E.2.6 Accessories 5 E.3 MAINTENANCE 5 E.3.1 Preventive maintenance 5 E.3.2 Pump Unit Dismantling 5 E.3.3 Change of pump piston seal 6 E.3.4 Pump valves 6 E.3.5 Valve shuttle 6 E.3.6 Valve rod sealing 6 E.3.7 Fault diagnosis 7 E.4 ENCLOSURES 8 E1 Data sheet 8 E2 Dimensioning of water- and air supply 9 E3 Part list 10 E4 Pump drawing 11 Airclean32/TF/02.11.2007

E.1 IMPORTANT INFORMATION 3 E.1.1 Safety Never point the gun at yourself or anybody else and hold it with both hands when spraying. A highpressure spray can penetrate the skin causing serious injury. Before service work, always disconnect the air supply. When cleaning, it is strongly advisable to use protective goggles, wear protective gloves and protective clothing. Never spray electrical equipment or cables unless you are sure that the installation stands high-pressure cleaning. Be sure that any part to be fitted withstands the pressure. If the cleaning unit is to be used in a hazardous environment, earthing the equipment will eliminate static electricity. Airclean is CE-marked. E.1.2 Lubrication The air motor requires lubricated air. In order to ensure uninterrupted steady operation you must never let the fitted air lubricator run dry. The correct position of the adjustment screw is approx. 1/2-1 turn. E.1.3 Air operating pressure Do not exceed maximum safe air operating pressure specified in data sheet, enclosure 1. E.1.4 Frost protection If frost is expected, the waterside must be emptied to prevent damage by frost. This is simple. Disconnect the water supply and let the unit run some strokes until the pump, hose, spray gun and extension tube is empty. Or change over the air supply to the water intake and blow the waterside dry. E.1.5 Guarantee The guarantee is not valid for damages caused by erroneous usage or if the unit has been disassembled without written permission from the manufacturer.

E.2 DESCRIPTION AND OPERATION 4 E.2.1 Pump unit The pump unit comprises a single acting pump powered by a double acting air motor. An air shuttle valve that changes the air direction when the piston reaches the end positions controls the air motor. E.2.2 Water inlet The connection is marked Water. Use a water supply hose with minimum diameter as specified in enclosure 2 Dimensioning of water- and air inlet. It is recommended to connect a low-pressure hose of minimum 3 meters length to the water inlet of the unit to prevent shock in the water system. The suction head capacity of the pump is reduced with increasing temperatures. Increased supply pressure may therefore be required when pumping hot water. The suction line must be free from leeks. Claw couplings are not suitable for suction lines with pressures below atmospheric pressure. E.2.3 Air inlet The air connection is marked Air. Use air supply hose with minimum diameter as specified in enclosure E.2 Dimensioning of water- and air inlet. Do not fit valves, fittings etc. with less diameter than specified in enclosure E.2. If regulation is required at the unit, it is recommended to fit a full-bore ball valve and use this for throttling the air supply. If you are going to use an air pressure regulator it must be plentiful dimensioned for the airflow. E.2.4 Chemical dosing A high-pressure injector fitted between the high-pressure pump outlet and the high-pressure hose may dose chemicals. You may need to turn down the water pressure by throttling the air motor to achieve that the injector will work properly. We recommend to disconnect the injector when not in use because it steals pressure. E.2.5 Cleaning procedures Hot water, if available, will always give the best result and reduces the need for chemicals. The following procedures are recommended to get the best result when working with detergents: - Apply the detergent with a wide-angle spray. Start at the bottom and move upwards. The spray distance should be approximately 40 cm. - Leave the detergent to work approx. 3 minutes, or according to the manufacturer s instructions. However, do not let detergent dry on the surface. - Start cleaning from the bottom and move upward. This prevents water to run down and dilute detergent below. The spraying distance should be 10 30 cm. - When cleaning is completed, wash down from the top to prevent stains. Use water generously.

E.2.6 Accessories 5 The Airclean standard scope of supply is tailored to cater for ordinary cleaning tasks in an efficient and economic manner. Special demands are met by made suit accessories, which may be procured when needed. Such accessories include: - Chemical injector. - Turbo nozzles and other nozzle types. - Sand blasting set for cleaning and de-scaling rusty steel structures etc. - Nozzles for opening clogged tubes. - Foam set for soap, disinfectants etc. - Air filters, water filters, couplings for water and air. - Extension tubes and extra hoses. - Airclean wheel lance. Complete lance system for efficient washing of high walls, ceilings etc. - Hose drums. E.3 MAINTENANCE E.3.1 Preventive maintenance Preventive maintenance is limited to filling of lubrication oil, visual inspection and cleaning. Particular attention should be paid to high-pressure leaks and high-pressure hose. High-pressure leaks should be repaired straight away as they may increase rapidly if left unattended. The method of repair depends on where the leaks occur: a. b. c. Pump Seal A leak pump piston seal will cause a flow of water out of the drain hole on the bottom side of the pump cylinder. Threads All threads are BSP standard. The sole exception is the spray nozzle, which is NPT. All threads are assembled with sealing liquid, and leaks will normally never occur. However, if leaks should occur the threads must be cleaned and reassembled using either a sealing liquid or thread tape. High-pressure hose couplings The high-pressure hose couplings have metal-to-metal seals. To stop a leak, tighten the nut until the leak stops. If this does not work, open the coupling and inspect the sealing surfaces. High pressure cleaning is the best method for cleaning the unit. If the plant air is contaminated, for instance by rust, an air filter should be fitted. A water filter should be fitted if the water contains abrasive particles. E.3.2 Pump Unit Dismantling The pump unit is assembled by means of lock rings and may be split at A or B (Pump unit drawing). For access to the pump piston seal undo the tie bolts.

6 E.3.3 Change of pump piston seal a. Loosen the attaching bolts. b. Pull the cylinder of the piston. c. Check the cylinder for scratches to see if honing or a replacement is required. d. Remove the lock pin for the front part of the piston and screw it off. Fit o-ring, pump seal and front part of the piston. e. Fit new slide rings. f. Lubricate piston, seal and slide rings to ease reassemble and prevent damages at start up. Reassemble sequence is opposite to dismantling, but note the following: g. Tighten the attaching-bolts two and two opposite at a time. Sealing liquid should be applied to the bolts. E.3.4 Pump valves The valve seats are fixed and are not removable. Proceed as follows to inspect/renew balls or springs: a. Undo attaching bolts and pull free the pump head to gain access to the inlet valve. The outlet reducer is fitted with sealing liquid. b. Clean and inspect parts. Remove loose scale etc. Replace worn parts. c. Clean threads. d. Fit parts according to drawing. e. Use sealing fluid on outlet reducer threads when assembling. Tighten opposite bolts to avoid skewing. E.3.5 a. b. c. E.3.6 a. b. c. d. Valve shuttle Unscrew threads end cover, remove dampening ring and pull out the valve shuttle. Dismantle, clean, inspect and replace parts as required. Re-assembly is done in reversed order. Screw in and end cover till it bottoms. Valve rod sealing Split pump unit by pulling lock ring B (See drawing)n5. Dismantle, clean, inspect and replace worn parts as required. Lubricate all o-rings prior to re-assembly. Re-assembly is done in reversed order.

E.3.7 Fault diagnosis 7 Symptom Possible Cause and Solution 1. Low delivery/pressure a) Restricted air supply. See E.2.3 Air inlet. Clean filters in the air supply. Open closed valves. b) Inadequate air supply capacity. Check compressor capacity. (See data sheet). Wrong nozzle bore. Change nozzle. Worn out nozzle. Change nozzle. 2. Uneven operation a) Inadequate lubrication. b) Insufficient air supply 3. Pump failure to start a) Pressure gauge on unit shows there is pressure: Clogged nozzle. Disconnect air supply and check for ice plug. b) Pressure gauge on unit shows no pressure: Closed air supply. Clogged air supply. No pressure in the air system. 4. Pump runs without delivery or low deliv- a) Closed water supply. ery Check any valves and filters in the supply. b) To large suction head. c) Undersized valves/fittings in the supply. d) Blocked/restricted air supply. e) Leaking pump piston seal. 5. Water/air leakages a) Defect pump piston seal or other seals 6. Pump over-speeds with no or low delivery a) Lacking or no water supply. Check valves and filters. b) To high suction head. c) Restrictions in water supply. d) Leaking pump piston seal. 7. Pump runs after trigger is released a) Pump inlet valve is damaged or blocked in open position. b) Leaking pump piston seal. 8. Pulsating spray a) Leaking suction line. b) Only 1 pump is working 9. Air motor stops and blows air a) Damage to o-ring seal(s) on air motor. Seals must be changed.

E.4 ENCLOSURES 8 E1 Data sheet Airclean 32 Pressure ratio 32 : 1 No of cylinders Air motor cylinder diameter Pump cylinder diameter Stroke Capacity Air consumption (free air, 1 bar) Recommended air pressure Pump pressure Maximum inlet water pressure Suction head up to 2 pcs 125 mm 22 mm 75 mm 0-24 l/min 0-7.5 m3/min(125 l/s) 5-11 bar 0-350 bar 25 bar 4 m Maximum inlet water temperature 150 C Water inlet nozzle Air inlet nozzle High pressure outlet Length overall Width overall Height overall (pump cart) High pressure hose Weight complete incl. hose, gun and lance Extension tube lenght 3/4 BSP female 3/4 BSP male 3/8 BSP male 720 mm 520 mm 980 (540) mm 3/8 x10 m 55 kg 700 mm MATERIALS Pump head Nickel and chrome plated st Pump valve seats Stainless steel AISI 316 Pump valve springs Stainless steel AISI 301 Pump piston seal PTFE/Carbon Piston rod Stainless steel AISI 303 Valve ball Stainless steel AISI 420B Pump cylinder JM3 seawater resist. bronze Air cylinder Nickel and chrome plated st Valve rod Stainless steel AISI 303 Frame Nickel and chrome plated st Tube parts Galvanized steel Cover Vacuum formed ABS Bolts Hot galvanized steel Spray gun Bronze/plastic Extension tube Nickel plated steel High pressure nozzle Stainless steel AISI 316 The unit will be delivered complete with 10m high pressure hose with spray gun, extension tube, spray nozzle, press. gauge, air lubricator and exhaust air muffler. Subject to be improved without notice

E2 Dimensioning of water- and air supply 9 RECOMMENDATIONS Airclean 32 HOSE DIMENSIONS Water supply Use minimum 3/4 hose. If the supply pressure is low or the hose is long, a 1 hose is recommended. Air supply Use minimum 1 hose. Do not fit valves or fittings with less inner diameter than 19 mm.

E3 Part list AIRCLEAN 32 PART NO U1200 PUMP UNIT 10 Part No Description Pos no Qty. P1002 Pump head 1 1 P1037 Hex nut 2 1 P1003 Stud screw 3 1 P1204 Piston rod 4 1 P1157 Glide ring 5 1 P1106 Air piston 6 1 P1007 Valve ball 7 2 P1008 Hex screw 8 4 P1019 Reduser 9 1 P1010 Spring 10 1 P1239 Pump cylinder 11 1 P1012 Cylinder cover 12 1 P1005 Spring 13 1 P1249 Pump piston 14 1 P1255 Glide ring 15 2 P1119 Ring 16 2 P1035 End cap 17 1 P1256 Pump packing 18 1 P1257 O-ring 19 1 P1045 O-ring 20 1 P1024 O-ring 21 5 P1123 O-ring 22 2 P1026 O-ring 23 6 P1025 O-ring 24 6 P1159 O-ring 25 6 P1158 Liner 26 1 P1166 Sleeve 27 1 P1027 Air cylinder 28 1 P1134 Valve shuttle 29 1 P1267 Valve housing 30 1 P1016 Snap ring 31 2 P1164 Sleeve 32 1 P1236 Valve rod 34 1 P1168 O-ring 35 1 P1080 Elbow 36 3 P1081 Hose nipple 37 2 P1082 Return line 38 1 P1083 Hose clip 39 2 P1084 Adapter 40 1

E4 Pump drawing 11