RHEOCHECK MD - Drive. Moving Die Rheometer controlled by Personal Computer.

Similar documents
RheoStress 600. The Modular High-Tech Rheometer

Product Information. Mflow extrusion plastometer

USV Ultra Shear Viscometer

MODULAR MELT FLOW: The First Step: Melt Flow Index (Weight Method) According to ASTM D 1238, ISO 1133 Method A and other equivalents

english Series 1 The versatile rheometer concept

The FMM force tester can be controlled using L1 software for limit, cycling, hold and coefficient of friction testing.

Accessories for the measurement of tightening torque. Digital and electronics dynamometric wrenches

DOLI's STANDARD COMPRESSION FLEXOMETER (GOODRICH FLEXOMETER)

Infinite F50 family INNOVATIVE EIGHT CHANNEL ABSORBANCE READERS WITH ADVANCED LED TECHNOLOGY. 21 CFR Part 11* 98/79/EC IVD-D*

ADU 5. Automatic Distillation Unit

Date and Time of Pre Bid Meeting November 22, 2016 at a.m

Manual Kinematic Viscosity Bath Tamson TV12

Infinite F50 family Reliable. Validated. Compact.

Points of strength. 63F, availability of two drilling heads, with possibility fo horizontal and vertical drilling devices.

VIDA RELEASE NEWS ABOUT THIS DOCUMENT RELEASE: 2013D INFORMATION TO INDEPENDENT OPERATORS

Compression/Tension Testing Machines

Callisto 100. Cold Filter Plugging Point Tester

SHOCK ABSORBER/DAMPER TESTING MACHINE

STANDARD TESTING FOR ELASTOMER (RUBBER) Part 1. General Rubber

Ton-Tel Multi-Deck Weighbridge

V-MV Variables Mooney Viskosimeter. Testing instruments. Laboratory Equipment. Software systems. Service. Consulting

Cooled incubators (ST), laboratory refrigerators

Everything under your control. No. 222/FCS ADVANCED FLUID MANAGEMENT SOLUTIONS FCS FULL OPTIONAL FCS BASIC

The Complete TPMS Solution. Universal TPMS Sensors and Programming Tool. Pre-programmed Direct-Fit TPMS Sensors

Being well-built is what counts. Thickness Gauges Automatic Systems for Extrusion-Dies

HS CYCLIC CUM STATIC TRIAXIAL TEST SYSTEM

Differential pressure transmitter PASCAL Ci4 Delta P

- New Superpave Performance Graded Specification. Asphalt Cements

Force Measurement Testing Systems

AutomAtic Strength tester AUTODYN

Heat Shield Portable wireless WBGT meter

Torque Solutions HALTEC HALTEC HALTEC HALTEC HALTEC HALTEC HALTEC HALTEC. Digital Torque Wrenches

HAAKE Series 1. The versatile rheometer concept. Analyze Detect Measure Control TM

TechPress 3. Product Brochure MOUNTING PRESS. Quality Products for Metallographic Sample Preparation & Analysis

For reliable control of small, large or multi-system-type lubrication systems

Active Interface Module Active Line Module chassis format, air-cooled

TQC s production facility is located in The Netherlands TQC has distributors in more than 60 countries TQC, DEVELOPERS AND MANUFACTURERS OF PAINT TEST

Differential pressure transmitter PASCAL Ci4 Delta P

AKVdiesel. Automated kinematic Viscometer key features. Fully complies with ASTM D445. Two measuring positions. Remove cap and pour in sample

Vertical Tensile Machine

TE 91 PRECISION ROTARY VACUUM TRIBOMETER

Wheel balancing with comfort WBE 424x / 444x

Pendulum Impact Charpy PIT Series Type C 450J

Servo-hydraulic Universal Testing Machine HUT Type DP

Battery-Powered Flow Transmitter

RHEO-TESTER 2000 Single-bore or dual-bore-system, with Windows user interface

Torsion testing machine

Hydro-Jet 3020 D 3040 D 3060 D 3080 D

LMC 301 controller. For reliable control of small, large or multi-system-type lubrication systems

Development test stands for E-motors

TE 88 MULTI-STATION FRICTION & WEAR TEST MACHINE

HTA-MB-TD Alignment Systems. Customized for aligning all Mercedes-Benz vehicles

Micro Motion ELITE High Capacity Coriolis Flow and Density Meters

Ritmo meets all your welding needs in your jobsite

Portable Transit Time Flow Meter for Accurate Flow Measurement from Outside a Pipe

Soft-Engine - Software 2TTool 2.0

THYRO-PX SERIES DIGITAL THYRISTOR SCR POWER CONTROLLER UP TO 2900 AMPS

FLUID CONTROL SYSTEM. No. 506-FCS EVERYTHING UNDER YOUR CONTROL FCS FULL OPTIONAL FCS BASIC ADVANCED FLUID MANAGEMENT SOLUTIONS

Cyclic Corrosion Chamber C.C.T AUTO Series

AUTOMECH MACHINES & TOOLS TRADING EST.

Digimar 816 CL. Versatile. User-friendly operation... The measuring program... Precise measuring results...

SERIES PRE PROPORTIONAL PRESSURE REGULATOR WITH COILVISION TECHNOLOGY

Hydraulic Deadweight Tester Model CPB5800

AXINET BATTERY MANAGEMENT SYSTEM. system for monitoring and controlling the performance of charger stations

Laboratory refrigerators

Portable CNC Cutting Machine PNC-12 EXTREME Ver.2.0R-1 for KOIKE NEWS No , March 2016 Koike Sanso Kogyo CO., LTD

Micro Motion T-Series Straight-Tube Mass Flow and Density Meters. Product Data Sheet PS July 2001

Differential pressure transmitter PASCAL Ci4 Delta P

Pendulum Impact Testing Machine

Viscometry Rheometry. The Range. ::: Intelligence in Rheometry

CFA. Carton Force Analyser

Sizing criteria for cylinders and servocylinders

KISSsoft 03/2013 Tutorial 2

Instruments for the Analysis of Petroleum Products. Oxidation Stability

HK Equipment CZD Brake tester Max. weight Size Roller size Measure range Error Rated use condition: CCH Sideslip tester 10,000kg (15,000kg) 3990 x 840

Model HRDT High Resolution Digital Telemetry Rotary Torque Transducer

SERVO-HYDRAULIC UNIVERSAL TESTING MACHINE SERIES D

Servo-hydraulic Universal Testing Machine HUT Type D

PMA 5. Pensky-Martens Flash Point Tester. ::: Volatility... Flammability

SolarPower. User Manual. Suitable Products: Three-phase grid-tie inverter with energy storage. Three-phase off-grid inverter

ElvaX Sulfur in Oil analyzer

ADVANCED. Cement Compression & Flexural Testing Machines.

Hari Shankar Singhania Elastomer & Tyre Research Institute, HASETRI, Plot No. 437, R&D Center, Hebbal Industrial Area, Mysuru, Karnataka

Cement Compression & Flexural Testing Machines

SolarPower. User Manual. Suitable Products: Three-phase grid-tie inverter with energy storage. Three-phase off-grid inverter

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

EASY-FORM SERIES. Hydraulic press brakes LVDGROUP.COM THE ULTIMATE BENDING MACHINE

for STANDARD, HYBRID and ELECTRIC VEHICLES with R134a refrigerant For the brands OPEL CHEVROLET (Europe) VAUXHALL KONFORT 760R

An Introduction to Fatigue Testing Equipment, Test Setup & Data Collection

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

BARON-MAX VL Range Vertical Machining Centers

Micro Motion F-Series Coriolis Flow and Density Meters

Tiny footprint. Big statement.

Technical News Bulletin

Vehicle Weighing. Vehicle Weighing Solutions. That help drive your business. Vehicle Weighing Solutions

C inch Back-Up Camera. Quick Start Guide

Smart Load Cell TRQ1/TPL torque / top load tester family

Humidity Cabinet HYGROTHERM

KM26z 20N; 50N; 100N, 200N, 500N, 1kN, 2kN, 5kN

EBI 3x0 PDF Data Loggers

Transcription:

RHEOCHECK MD - Drive Moving Die Rheometer controlled by Personal Computer.

RHEOCHECK MD - Drive Moving Die Rheometer controlled by Personal Computer. Overview The Rheocheck MD - Drive measures the cure characteristics of a rubber compound in conformity with the international standards ISO 6502-3 and ASTM D 5289. The measure of the vulcanisation is performed by measuring the evolution of the mechanical characteristics of the sample. The instrument applies a cyclic strain to a test piece and measures the torque resistance of the sample. The test is carried out at a constant temperature and the measure of stiffness is recorded continuously as a function of time. Development and production The instrument is totally developed and produced in the plant of Gibitre Instruments in Italy. All the mechanical parts are produced in the company workshop using modern CNC machines. Components and sensors from well-known brands are selected in order to ensure the maximum reliability in the measures Internal trained personnel takes care of all the production stages: assembly, start-up, calibration, packing, shipment and installation. Construction characteristics Solid steel frame with epoxy powder coating. Easily accessible test area with transparent safety panel and safety lock. Die closure system with 4 columns structure to ensure long time stability. The top part of the frame is designed for the connection to a fume aspiration system Air filter and pressure regulation unit for pneumatic devices is integrated into the instrument.

video

RHEOCHECK MD - Drive Test dies Pressurized test chamber conforming to the international standards. The formulation for the seals has been specifically developed by Gibitre to ensure Low friction and long duration. The micrometric adjustment of the distance between the chambers is carried out independently by the exclusive mechanical adjustment vernier. The device allows you to easily adjust the thickness of the specimen to meet the requirements of ISO 6502-3. The thermal insulators, used to avoid heat transmission, have been chosen for their excellent mechanical characteristics and low thermal conductivity. The insulators are coated with a surface treatment based on fluorinated polymers, which ensures extremely high resistance to chemical agents and ease of cleaning. Temperature regulation The regulation of the temperature is performed using thermo-regulators with PID micro-processor and with 0.1 C resolution. Independent temperature control units ensure sophisticate temperature control and easy replacement in case of failure. Electrical heating resistances have been specifically designed for this instrument to ensure quick and efficient heating. The test chambers are equipped with a compressed air cooling circuit, controlled by the temperature control units, which allows rapid temperature reduction. Die oscillation control The kinematic for the oscillatory movement of the lower test chamber has been developed to ensure perfect operation of the instrument under heavy operating conditions and for extremely long periods: Siemens motor SKF bearings Calibrated gauges are supplied together with the instrument to easily set the oscillation angle to 0.5 or 1,0.

Torque transducer The Interface torque transducer is positioned in the upper test chamber to minimize the influence of friction and vibrations. See also on www.gibitre.it Instrument control devices The instrument is equipped with a large touch-screen display with dimensions 10.2. The buttons on the display permit to start and stop the tests. The display provides complete information about the status of the instrument: connection to the software, temperature of the dies, diagnostic of the sensors installed. A light panel, installed in the front part of the instrument, changes the color and permits to check the status of the instrument from a distance. The indicator light identifies the following statuses: Instrument ready, instrument under test, instrument setting test temperature, no specimen in the queue (with autoloader). Oscillating Disk Rheometer: RheoCheck Profile OD - PC Mooney Viscometer for the performance of Viscosity, Scorch and Stress Relaxation tests: MooneyCheck Profile - PC Pneumatic Die Cutter for the preparation of samples with constant volume: Volumetric Die Cutter

RHEOCHECK MD - Drive Pressure control The instrument can be optionally equipped with a pressure sensor for the testing of the expansion evolution of the sample during the curing. This option is useful for the analysis of cellular rubber formulations. Calibration The calibration of the instrument is performed in conformity with the requirements of international standards. The report includes the following calibration steps: distance between the test dies, temperatures of the upper and lower dies, thermal recovery time at the beginning of the test, oscillation angle, oscillation frequency, closing force of the testing chambers, measurement of torque, measurement of the calibrator spring supplied to the customer, dimensions of testing dies (optional). Automatic sample loader The device allows to position 5 test pieces on the loading slide and automatically perform the tests on all the samples. Before starting a test, the software automatically regulates the instrument according to the test conditions required for the next sample in the queue. When the test conditions are within the expected tolerance limits, the sample loader moves the sample in the right position and starts the test. The calibration report includes complete traceability to the reference instruments used. The calibration report includes the final check made with Gibitre standard rubber.

Safety devices The instrument is equipped with Class 1 Safety switch, which prevents the closure of the dies if the safety panel is not closed. Accessories Volumetric Die Cutter for the preparation of samples with constant volume required by the standard. The safety Pushbutton and safety lock of the maintenance access door ensure safe usage even in non-standard operation conditions. The instrument is fully complient with CE safety regulation. Polyester film rolls for the execution of tests with automatic sample loader. Box of polyamide or polyester film sheets to perform tests without automatic loader.

RHEOCHECK MD - Drive Gibitre-Rheo-Interactive software The software is connected to the standard SQL Gibitre database to ensure safe and solid storage of test results and curves. The program permits quick and easy identification of the tests to be performed and is optimized for the use of bar code reader (or similar identification device). Before the test start, the program activates the test procedure set for the product, automatically adjusts the instrument and sets the tolerance limits for the verification of the results. During the test you can plot the elastic curve (S ), viscose curve (S ), complex curve (S*), Tan-Delta curve, curing speed and the temperatures of the dies. At the end of each test, the elastic curve is overlapped to the ones of the previous tests for immediate comparison. The curves are plot with different colors for easy identification. At the end of the tests the program saves the results, verifies the conformity with the tolerance limits and processes the statistical analysis (X-Chart, Gaussian, Media, St. Dev., Max, Min, Cp, Cpk). In any phase of operation of the instrument, the program is ready to receive the input of data related to the next samples to be tested. If a barcode reader (or other automatic identification device) is used, the complete identification is performed by a single click. Depending on the selected product, the program automatically selects the test procedure to be used for the specimen Programma Rheo-Interactive If the autoloader is used, the instrument waits for the test specimen test temperature to be reached and starts the test. The program checks the conformity of the results with respect to the tolerance limits set for the product

Test report Can be printed or saved to pdf in one of the available languages. The format of the Test Report can be customized by the user. Datagest Program The Datagest program is the database management tool always installed in combination with all Gibitre instrument-control programs. The program permits to: - Select, filter, print, export and analyse the test results stored with all the instruments connected. - Prepare test procedures by defining the test conditions and the results to be produced - Set tolerance limits for each product by manual insertion or using the statistical analysis (mean and standard deviation) of saved results - Prepare multi-instrument test reports IN: Company database OUT: Statistic analysis OUT: Data export OUT: Test report Industry 4.0 integration The instrument and the software have been specifically developed to optimize integration with other environments. The database in SQL format and the Gibitre_Company_Connect program allows you synchronize your company management software with Gibitre database and to speed up the identification of the tests and to use bar-code readers or similar devices. The automatic logging service permits to send alarm information to the cloud-service platform of Gibitre Instruments in order to optimize the reaction times of the Service Support.

RHEOCHECK MD - Drive - TECHNICAL DETAILS STANDARDS Standards the instrument complies with ISO 6502-3; ASTM D 5289; DIN 53 529-3 SOFTWARE Numerical test data Torque Time Scorch Pressure (optional) Test Curves MI, ML, MX, MH, PCR, S @ML, S @MH, TanD@ML, TanD@MH, G @ML, G @MH, G @ML, G @MH, G @X, G @X. t90, tx, tml, tmh, tpcr, trx, CRI (X= customer - defined) ts1, ts2, tsx PL, PH, tp, MPR, tmpr (For each test procedure up to 20 test results can be selected) Elastic curve (S ), viscose cure (S ), complex curve (S*), Tan-Delta curve, curing speed, temperatures of the dies Units Torque dnm or lbf.in Time minutes and seconds, minutes and minutes/100, seconds Temperature C, F Selectable Languages Italian, English, French, Spanish, German, Portuguese, Russian, Chinese, Japanese, Turkish, Polish, Czeck CONTROL PANEL Characteristics dimensions 10.2 Type of device Data displayed capacitive display (permits the use with gloves) active connection to the software, motor on-off, temperatures of the dies, heating status, sample on sample-holder (with sample loader), test running LIGHT PANEL Permits to check from a distance the following statuses Instrument ready, instrument under test, instrument setting test temperature, no specimen in the queue (with autoloader) CONSTRUCTION CHARACTERISTICS Electronic card Electronic card with STN 32F 429 micro-processor Torque Sensor Brand Interface Capacity 20 N*m Resolution 0.01 dn*m Linearity Error (%FS) +-0.25 Pressure Sensor (opzional) Brand Interface Resolution 0.1 kpa Capacity 10 kn Linearity Error (%FS) +-0.25 Oscillation frequency 100 cycles/minute (1,7 ± 0,1 Hz) Oscillation angle 0.5, 1. Calibrated gauges are supplied together with the instrument to easily set the oscillation angle to 0.5 or 1,0. Temperature between room temperature and +250 C - Resolution 0.1 C Cooling system compressed air cooling circuit Power supply 220 VAC ± 10%, 50-60 Hz ± 3, 4 A, single phase 110 VAC ± 10%, 60 Hz ± 3 on request Power 700 Watt Compressed air 6 bar. Complessed air regulation unit integrated into the instrument

Dimensions and weight Without sample loader (W x D x H) With sample loader (W x D x H) Weight 671 x 684 x 1419 mm 1229 x 684 x 1419 mm 180 Kg SAFETY DEVICES Class 1 Safety switch for main piston (Idem) Safety Pushbutton Safety lock of the maintenance access door CE labelling OPTIONS Automatic sample loader Volumetric Die Cutter Automatic test of 5 samples for the preparation of samples with constant volume CALIBRATION Calibration Report with traceability to primary standards Torque calibration spring supplied with the instrument PERSONAL COMPUTER (optional) Minimum configuration Compatible Operating Systems Connection to the instrument Intel Core i3 2 GB RAM Windows 7, 8 and 10 (64 bit) USB port

Gibitre Instruments s.r.l. Via dell Industria, 73 24126 Bergamo - Italy Tel.: +39.035.460146 Fax: +39.035.460687 customer.service@gibitre.it We reserve the right to make changes in design and specifications without further notice www.gibitre.it EN003.000.1