ISO 5011 Test Results

Similar documents
TEST RESULTS. Certified to the ISO 5011 Air Filtration Standard

TEST RESULTS. Certified to the ISO 5011 Air Filtration Standard

ISO 5011 Test Results

ISO 5011 Test Results

ISO 5011 Test Results

ISO 5011 Test Results

ISO 5011 Test Results

TEST RESULTS. Certified to the ISO 5011 Air Filtration Standard

ISO 5011 Test Results

ISO 5011 Test Results

TEST RESULTS. Certified to the ISO 5011 Air Filtration Standard

TEST RESULTS. Certified to the ISO 5011 Air Filtration Standard

ISO 5011 Tested to Make Sure You Maximize Airflow While Still Protecting Your Engine.

ISO 5011 Tested to Make Sure You Maximize Airflow While Still Protecting Your Engine.

Direct Flow Air Cleaners DF600 Series

Turbocharger Compressor Calculations

UNITED STATES DEPARTMENT OF AGRICULTURE FOREST SERVICE STANDARD FOR SPARK ARRESTERS FOR INTERNAL COMBUSTION ENGINES

PowerCore Air Cleaners Two-Stage

Retrofit Crankcase Ventilation for Diesel Engines

2. provide data indicating what types and sizes of particles are not removed by used PHEAF devices, and

OIL BATH INTAKE AIR FILTERS. Capacities up to 6500 CFM

MnI Diesel, LLC MnI Maintenance, LLC. Setting the Standard in Oil Filtration Keep It Clean! & Keep It Green!

Table of Contents. 4. Before a New Turbocharger is Installed

Modern Automotive Technology Chapter 16. Engine Size and Performance Measurements

Effectiveness of Cabs for Dust and Silica Control on Mobile Mining Equipment

Daytona Prototype - Chevy Race Engine Ford GT Supercharger Coolant System Performance & Protection Presentation

Installation manual. Intake system and ventilation. Industrial engines DC09, DC13, DC16 OC16. 01:02 Issue 10 en-gb. Scania CV AB 2018, Sweden

PowerPleat Air Cleaners

Innovative Filtration Solutions

Managing Particle Contamination with Chevron ISOCLEAN Certified Lubricants

PRELIMINARY. Engine Speed Standby Power Prime Power Continuous Power. RPM kwm BHP kwm BHP kwm BHP. Litre / hour

1104D-44T Industrial Diesel Engine

2/4/6.3, PAH 10/12.5, PAH 50/63/70/80/100 pumps

Cummins Techical Operations

EMI / RFI Shielding Products. Shielding Honeycomb Ventilation Panels and Dust Filtration Characteristics

Using Multiple Cylinder Engines

Filtration Products Extended service filters Increase engine protection Extend service intervals Reduce operating costs

FPG & FPG Alexin Air Cleaners

PowerPleat Air Cleaners

[You may download this article at: ]

Engine Cycles. T Alrayyes

Setting the Standard in Oil Filtration Keep It Clean! & Keep It Green!

PowerCore Air Cleaners Two-Stage: PSD and Single-Stage: PCD

FOR AIR CONDITIONING AND VENTILATING APPLCATIONS

Technical Data. 400 Series 403D-15G. ElectropaK

Effectiveness of Cabs for Dust and Silica Control On Mobile Mining Equipment

PANELS OIL BATH INDUSTRIAL AIR INTAKE FILTERS

APP S 674 pumps APP S / APP S APP S

See Note. 100% of rated load 2,4,6, (17.73)

Unit C: Agricultural Power Systems. Lesson 6: Using Multiple Cylinder Engines

Inlet House Air Filters Presented By: Zahi Youwakim

PAHT pumps / PAHT G pumps / ATEX PAHT G pump

Service Access Cover. Vacuator Valve. Accessories

CAGI Data Sheets. Blower Performance Comparison. Stephen Horne, Blowers Product Manager Kaeser Compressors, Inc.

UNDERSTANDING ROD RATIOS

High efficiency compressed air filtration & water separation

Revised AEM DRYFLOW Cold Air Intake MINI Cooper S and Clubman S 1.6L Turbo Engineering R&D Summary

STG Donaclone Air Cleaners

Property of American Airlines

1104D-44TA Industrial Diesel Engine

Cummins and Fleetguard are registered trademarks of Cummins, Inc. Mann+Hummel is a registered trademark of Mann+Hummel GMBH

854F-E43TA Industrial Diesel Engine

Catalog & SalesManual

2.61 Internal Combustion Engines

Focus On Training Section: Unit 4

quatroair.com AIR TECHNOLOGIES INC.

854E-E34TA Industrial Diesel Engine

@Perkins. Technical Data Series 2806C-E18TAG1A. Diesel Engine - ElectropaK. Basic technical data. Cyclic irregularity. Ratings.

Generator set data sheet 1000 kw continuous. Fuel type: Natural gas MI 62 +

Power Rating Minimum Rating 429 bkw 575 bhp Maximum Rating 470 bkw 630 bhp Rated Speed

@Perkins. Technical Data Series 2806A-E18TAG1A. Basic technical data. Cyclic irregularity for engine/flywheel maximum: Ratings.

KTA50 Land Based Drilling Power Modules

@Perkins. Technical Data. 400 Series 403D-11G. ElectropaK

MITSUBISHI DIESEL ENGINE IFM NO. JN (1/6) TECHNICAL INFORMATION DATE Aug. 8, 2002

SCK. Air Compressors SCK

Ultra-Web HD. SSG Donaclone Air Cleaners. Designed for the Worst Dust Conditions New Choice for Construction and Off-Highway Applications

PAHT pump PAHT X

See Note. 100% of rated load. Mechanical efficiency ISO3046/1 2,4,7 35.2% 34.8% 34.1% Electrical efficiency ISO3046/1 2,4,6,7 33.7% 33.4% 32.

See Note. 100% of rated load

AN UPDATE TO THE SAE S-12 COMMITTEE ON ACCEPTABLE MEANS OF COMPLIANCE FOR IBF POWER AVAILABLE AND DISTORTION EASA 11TH ROTORCRAFT SYMPOSIUM

Technical Data TWG2A TWG3A Series. Diesel Engine - ElectropaK rev/min. Basic technical data

TECHNICAL DATA DEPT. CERTIFIED WITHIN 5% CHIEF ENGINEER

See Note. 100% of rated load

See Note. 100% of rated load

FRG Air Cleaners. Superior Protection for Larger Engines RadialSeal Sealing Technology Means Reliable Filtration and Quicker Service

Technical Data Series 1204E-E44TA. Basic technical data. Performance

AMSOIL Ea Air, Oil and By-Pass Filters

See Note. 100% of rated load

MODEL PERFORMANCE. ENGINE MOUNTING Maximum Bending Moment at Rear Face of Block... lb ft (N m) 1000 (1356)

See Note. 100% of rated load

@Perkins. Technical Data

CAGI Data Sheets. Blower Performance Comparison. Stephen Horne, Blowers Product Manager Kaeser Compressors, Inc.

Cylinder Balance and Percent Changes Lesson 11

This is a new permit condition titled, "2D.1111 Subpart ZZZZ, Part 63 (Existing Non-Emergency nonblack start CI > 500 brake HP)"

400 Series 403D-11G ElectropaK rpm

Direct Injection Ethanol Boosted Gasoline Engines: Biofuel Leveraging For Cost Effective Reduction of Oil Dependence and CO 2 Emissions

we make clean air Air Filtration Solutions Industrial Commercial Residential quatroair.com AIR TECHNOLOGIES INC.

2010 MaxxForce 11 and 13L Diagnostics

HEPA FILTERED AIR FILTRATION EQUIPMENT MAY NOT BE HEPA FILTERED

Cylinder Head Comparison Sheet Big Block Mopar

Transcription:

ISO 5011 Test Results Certified to the ISO 5011 Air Filtration Standard Cold Air Intake Kit 2005-08 Ford Mustang GT V8-4.6L Part Number 75-5003

ISO 5011, Second Edition Performance Testing: Inlet Air Cleaning Equipment for Combustion Engines & Compressors ISO 5011Test Results Explanation - Course Test Dust.doc ISO 5011, Second Edition Air Filter or Intake Kit Test Report The test data presented in the following report represents the restriction of airflow, efficiency and dust loading capacity. The filters tested were procured from various distributors or provided by customers. The tests were performed in accordance with ISO 5011. The following were measured in accordance with the test: (1) Pressure Drop for Clean Element, Initial Efficiency and Dust Loading Capacity. The Flow Rate used to conduct the Dust Loading and Capacity test(s) is listed under the Average Environmental Conditions and Test Specifications. PTI ISO Course Test Dust was utilized and the particle data sheet for the batch is attached. The test sequence begins with measuring the pressure drop of a clean filter as a function of the airflow rate which is measured in cubic feet per minute (CFM). Subsequently, the cumulative efficiency and dust loading capacity are measured. The termination point when measuring for capacity is shown at the bottom of the report under the heading Termination ^P. The results of the tests are recorded in the top table and charts shown on the next page. The filters are inspected before and after the tests are performed. The Top Table demonstrates the results of the testing for up to three (3) samples per filter type (part number). The Efficiency represents the amount of dust (contaminants) that was stopped by the filter during each test. The Capacity measures the dust holding capability of the filter. During the test, the filter is loaded with dust until it reaches a terminal pressure drop increase of 10 inches of water (28 H2O for Heavy Duty Vehicles) across the filter element (please refer to the Average Environmental Conditions and Test Specifications at the bottom of the next page to verify the pressure drop utilized on this particular test). The Line Graph shows the pressure drop as a function of the airflow rate for the clean filter(s). The computer controlled test equipment initiates the test at close to zero (0) cubic feet per minute (CFM) and then increases the CFM gradually until the CFM termination point is reached. During the test, the restriction of the filter is measured in inches of water ( H2O) as it relates to the air flow rate (CFM). Visual inspections of filters are performed to insure against dust leakage and manufacturing flaws. The Bar Graph illustrates the cumulative efficiency for the filter(s) tested. Definition of Terms & Test Protocol Restriction Restriction measures how difficult it is for the air to get through the filter and is measured in inches of H2O. Instead of referring to restriction, the industry uses "air flow" to describe the effect of restriction. They say for example, that a High Performance Filter "flows better" than the OEM paper filter. On a line graph, the lower the restriction of a filter the better the air flow. Efficiency Efficiency is measured in % and is the amount of dirt/contaminants that the filter stops from going into the engine. Capacity Capacity is the total amount of contaminants/dirt the filter will hold before reaching its termination point. The termination point is a predefined restriction point that is used as the cut-off point when measuring how much dirt a filter will hold. For typical vehicles, 10 H2O is used at the termination point. For heavy duty trucks, this number is 28 H2O. Note: Testing was conducted based on the ISO 5011 testing standard; however, variances from the actual test procedures may exist. The intent of the testing is to show comparative test results between various products that are intended for similar use. Tests are conducted under a climate controlled environment; however, changes in temperature and humidity between tests may occur which could alter the actual test results.

ISO 5011 Air Filtration Standard Intake Kit Comparison S&B Filters75-5003 Test Number 245 Filter PLEAT INITIAL RESTRIC. CAPACITY EFFICIENCY Air Flow Net Restriction % Less Restrictive than Mfg. & Part No. COUNT ("H2O) (grams) (%) cfm (Inches of H2O) OEMFord Filter #1 54 5.2 63.0 99.24 0.0 0.000 0.0% S&B Filters 187.0 1.877 53.4% 75-5003 280.9 3.899 53.6% 374.7 6.601 54.5% 469.6 9.991 55.6% 558.4 14.143 56.8% Filter #2 68 6.1 211.9 99.76 0.0 0.000 Ford 186.7 4.024 OEM 280.3 8.401 372.9 14.502 466.6 22.514 560.8 32.730 SUMMARY RESTRICTION vs FLOWRATE 25.000 75-5003 OEM 20.000 Avg Restriction (" H2O) 15.000 10.000 5.000 0.000 0.0 50.0 100.0 150.0 200.0 250.0 300.0 350.0 400.0 450.0 500.0 Flow Rate (cfm) ISO 5011 Air Filtration Test Filter Efficiency % ISO 5011 Air Filtration Test Air Flow Summary 100.00 98.00 S&B Filters 99.24 Ford 99.76 05' Ford Mustang GT 4.6L V8 S&B Filters Part Number 75-5003 Flows: 96.00 54.5% Better Than Filter # 2 at rated CFM 94.00 54.8% Better Than Filter # 2 Across CFM Spectrum % 92.00 90.00 88.00 86.00 1 AVERAGE ENVIRONMENTAL CONDITIONS & TEST SPECIFICATIONS Temperature: 71.14 deg F Housing: OEM & universal Relative Humidity: 51.33 % Contaminant: Coarse Baro Pressure: 28.58 mmhg Contam. Lot #: 5336C Test Stand: #1 Dust Feed Rate: 10.47 grams/minute Inlet Size: 3.75 inches Rated Flow: 374 cfm Testing was conducted based on the ISO 5011 Air Filtration standard.

Determination of Gasoline and Diesel Engine Air Consumption CFM Calculator: Enter Data in Blue Shaded Areas Engine Displacement (cubic inches) 280.7 Liters to CID Converter Liters: 4.6 RPM at maximum horse power 5,750 Cubic Inches: 280.7 Cycle Factor: 2 Enter "2" for 4 Cycle Diesel and Gasoline Vehicle Information Enter "1" for 2 Cycle Diesel and Gasoline Model Year 05' Volumetric Efficiency: 0.8 Make Ford Naturally Aspirated Gasoline & Diesel Engines Enter "0.8" Model Mustang GT Super Charged Diesel Engines Enter "1.30" Engine Specs 4.0L V8 Turbocharged Diesel Engines Enter "1.75" Based on the information entered above, the estimated CFM of the vehicle at maximum Horse Power is: 374 CYCLE FACTOR Cycle Factor 4 Cycle Diesel and Gasoline Engine 2 2 Cycle Diesel and Gasoline Engine 1 VOLUMETRIC EFFICIENCY Volumetric Efficiency (Approximate) Naturally Aspirated Gasoline & Diesel Engines 0.8 Supercharged Diesel Engines 1.30 Turbocharged Diesel Engines 1.75 Note: The 1.75 volumetric efficiency is applicable only at top governed engine speed under full load conditions. EQUATION The following is a method of determining approximated gasoline and diesel engine air flow requirement: Air Flow (CFM) = Displacement (cubic inches) x RPM x Volumetric Efficiency 1728 Cycle Factor EXAMPLE Information necessary to calculate air consumption: Ford F250 7.3L V8 Diesel Truck 4 cycle, 2800 RPM, 443.1 (cubic inches) displacement, turbocharged Air Flow (CFM) : 443.1 x 2800 x 1.75 = 628 CFM 1728 2