Model 412. Opening a Whole New World: FAAC Swing Gate Systems. High and Low Voltage

Similar documents
Model 400. Opening a Whole New World: FAAC Swing Gate Systems SWEETS UL 325 COMPLIANT CSI # Gate Operators

UL 325 COMPLIANT CSI # Gate Operators. Gate-safe: during power outages, a magnetic lock releases a closed gate to permit emergency access.

VEHICULAR DC SWING GATE OPERATORS. Residential Light Industrial. Rev. 3/17

VEHICULAR AC & DC. Residential Apartment/College Residence Halls Gated Communities Mixed Use Buildings Commercial/Industrial Parking Self Storage

J SERIES BOLLARDS Solutions for vehicle access control and city traffic

UL (9050, 9100, 9150) PG. 10 PG.

January 2018 PRICE SCHEDULE A 2.0 Vehicular Traffic Control

January 2018 PRICE SCHEDULE A 2.0 Vehicular Traffic Control

January 2018 PRICE SCHEDULE A 2.0 Vehicular Traffic Control

Section A1. Vehicular Gate Operators. This Price Schedule is effective June 1, Date Page Comment All June, 2016 Price Schedule update.

SERIES 940. Automations for sliding doors

Section A1. Vehicular Traffic Control. This Price Schedule is effective January 7, Date Page Comment

Section A1. Vehicular Traffic Control. This Price Schedule is effective January 7, Date Page Comment

CONTENTS T HE 400 OPERATOR AND 455 D CONTROL PANEL: I NSTALLATION MANUAL

The 760 Operator and 450 MPS Control Panel: Installation Manual

January 2018 PRICE SCHEDULE B 1.5 Maximum Security Slide Gate Operators

CONTENTS T HE 415 L LS OPERATOR AND 425 D CONTROL PANEL: I NSTALLATION MANUAL

CONTENTS T HE V OPERATOR AND 425 D CONTROL PANEL: I NSTALLATION MANUAL

The 750 Swing Gate Operator and 450 MPS Control Panel: Installation Manual

A140 Air Automations for sliding doors

CONTENTS T HE 422 OPERATOR AND 455 D CONTROL PANEL: I NSTALLATION MANUAL

June 2016 PRICE SCHEDULE A 2.0 Vehicular Gate Operators

Actuator Arm and Control Box Mounting

115 VAC Control Boxes for

Gilgen FD 20 swing door drive unit

T-MODE. Automated systems for rolling shutters and sun blinds

COMMERCIAL 24VDC HIGH TRAFFIC OVERHEAD DOOR AND GATE OPERATOR WITH BATTERY BACKUP INSTALLATION MANUAL

The 820/860 Slide Gate Operator: Installation Manual

Type of installation. external motor. underground motor. Leaf max length (m) Leaf max length (m) Max leaf weight (kg) V V V

Installation/Owner s Manual

115 VAC Control Boxes for

115 VAC Control Boxes for

Apartment Complex/Gated Communities Mixed Use Buildings Commercial/Industrial Parking Self Storage Maximum Security

Installation/Owner s Manual Series 6500

AC Powered. AC Powered. Model Installation/Owner s Manual. UL 325 Compliant. AC Powered Vehicular Swing Gate Operator

Installation/Owner s Manual

Installation/Owner s Manual

MODEL D-SBG Single Arm Barrier Gate Operator

GILGEN FD 20 SWING DOOR DRIVE UNIT

Gilgen FD 20 swing door drive unit

VEHICLE AND PEDESTRIAN CONTROL

Vehicular Swing Gate Operator. Nice. Titan 912L. The Titan 912L Gate Operator is intended for use with vehicular swing

AC Powered. AC Powered. Model Installation/Owner s Manual. AC Powered Vehicular Swing Gate Operator. UL 325 August 2018 Standard

Auto Gate System. General Description. Features EL-888A. elock EL-888A is an electro-mechanical complete system for. EL-888A (Auto gate)

MAX MEGATRON. Residential / Commercial Brushless DC Swing Gate Operators. Installation and Owners Manual.

Installation/Owner s Manual Series 6500

FSW 900 Swing Gate Operator

Installation/Owner s Manual 1601 / 1602

Certification and Product Usage Inside Back Cover ACCESS SYSTEMS

Owner s Manual. Models 6050 and 6100 Vehicular Swing Gate Operators

Typical Installation Schematic

MODEL MSW Medium Duty Swing Gate Operator

MODEL D-WBG Wishbone Arm Barrier Gate Operator

Installation/Owner s Manual Series 9000

Installation/Owner s Manual 6400 Vehicular Swing Gate Operator

Installation/Owner s Manual 1601 / 1602

SWING GATE OPENERS 24V DC GEAR MOTOR

Raising Standards in Accessibility

Installation/Owner s Manual 9245

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

Installation/Owners Manual

Actuator Arm and Control Box Mounting

access

UGP-712 Vehicular swing gate operator

Installation/Owner s Manual Series 9500

Installation/Owners Manual PATRIOT RSL Vehicular Slide Gate Operator Heavy Duty Battery Powered Solar or AC Charged

Installation/Owner s Manual Model 9100

Solar Powered. Solar Powered. Model Installation/Owner s Manual. Solar Powered Vehicular Swing Gate Operator

RAM TABLE OF CONTENTS

AC Powered. AC Powered. Installation/Owner s Manual Model AC Powered Vehicular Slide Gate Operator

Swing-door drive unit FDC and F4 Compact. Universal. Reliable.

WARNINGS FOR THE INSTALLER

Eagle Access Control Systems, Inc. / (800) / (3)

Owner s Manual. Series 6050 and Vehicular Swing Gate Operator. Copyright 2010 DoorKing, Inc. All rights reserved. WARNING

Solar Control Box for

Owner s Manual. Model 9150 Vehicular Slide Gate Operator

Installation/Owner s Manual

Installation/Owner s Manual Model 9050

Installation/Owner s Manual Series 9150

Installation Instructions

PowerMaster MODEL MBG. Installation Manual U L R UL 325 AND UL 991 LISTED MEDIUM DUTY BARRIER GATE OPERATOR TABLE OF CONTENTS

Gate Operators, Inc. Model 7100UL Residential & Medium Duty Commercial Slide Gate Operator INSTALLATION MANUAL

Owner s Manual. Model 9300 Vehicular Slide Gate Operator

Compact Sliding Door Operator Dor-O-Matic 2900 Series

Owner s Manual. Model 9310 Vehicular Slide Gate Operator

#366. Gate Operator Pre-Installation and Site Planning. Introduction

INSTALLATION M ANUAL

RAMSET

Ditec PWR Automation system for swing gates with wings up to 5 metres

PW320/PW330 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL. Flashing Light. Push Button. Control box. Gate 2.

Saimatic Aster Gate Operator, Automation System Manual. 110V or 220V

INSTALLATION MANUAL MODEL LA412 RESIDENTIAL DC SOLAR VEHICULAR SWING GATE OPERATOR. UL991 compliant. UL325 compliant. LA4121PKGDC Single Arm Package

Installation/Owner s Manual Series 9000 Vehicular Slide Gate Operator

Installation/Owner s Manual Model 9100 Vehicular Slide Gate Operator

MOTORS RESIDENCIAL / INDUSTRIAL

Installation/Owner s Manual Series 9000 Vehicular Slide Gate Operator

In-Head Automatic Swing Door Operator DORMA. ED 200i

PowerMaster Model SG

Automation systems for swing gates hydraulic

6002 swing gate actuator - installation guide

Transcription:

Opening a Whole New World: FAAC Swing Gate Systems Model 412 High and Low Voltage Swing Gate Operators Slide Gate Operators Barrier Gate Operators Accessories The Model 412 electromechanical swing gate operator is designed specifically for light single family residential use. The Model 412 is UL 325 compliant. FAAC is the world s largest specialized manufacturer of gate operating equipment. A Solar kit is available on the Model 412 Low Voltage.

Model 412 Electromechanical Swing Gate Operators The Model 412 electromechanical swing gate operator is designed specifically for light single family residential use. Standard features include mechanical locking in the opened and closed positions, and in the event of power failure, a battery back-up unit will automatically open the gate. A convenient manual release is also standard. The Model 412, like other FAAC swing gate operators, is inherently safer because it has fewer pinch points. In addition, the force it applies to move the gate is adjustable for extra entrapment protection. The 412 Low Voltage provides a soft stop slow-down feature that allows for smooth operation and reduces stress on the gate and operator. The 412 can be mounted inside the gate and still allow the gate to open to the inside or to the outside. All FAAC operators can be finished to blend with your gate. All swing gates require gate stops that limit the travel of each gate leaf and thus protect the operator. Optional positive stops are available. Model 412 Kit includes: (for bi-parting gates). Two gate operators with mounting hardware. One 424 MP-B control panel. Operates single leaf or bi-parting gates. One 14 x 16 in. weather resistant UL Listed fiberglass enclosure. Two photobeam sets for opening and closing reversing devices. One plug-in radio receiver. Two radio transmitters. Two batteries and plug-in transformer. Four warning signs A solar kit is available for the Model 412 Low Voltage A convenient manual release is standard on all models.

Use FAAC to build a complete gate system Model 424MP-B pre-wired control panel Telephone entry systems Electric and magnetic locks Some access control options to open a gate Battery back-up Loops and photobeam safety Model 412 electromechanical swing gate operators Photobeams The Model 412 offers: Positive gate stops Positive gate stops, which limit the travel of each gate leaf, are required in the opened and closed positions for all gate systems using FAAC operators. FAAC offers three innovative gate stops. The Stop-O-Matic Model 70 is an adjustable gate stop that attaches slightly above the space between the operator and gate. The Stop-O-Matic Model 125 attaches independently from the operator. Features include:. Stainless steel construction. Mounts with existing FAAC hardware and does not require additional attachment points. Accommodates inward or outward swing with no additional fabrication. Maximum degrees of swing: limited by operator. Maximum leaf length & weight: limited by operator. Designed for light residential, single family use. UL 325 compliant. Mechanical locking in the opened and closed positions. Easy interconnection of loop detectors, photocells, etc. to reverse a gate if an obstacle is sensed. Easy interconnection of actuating devices like remote control radios, key pads and telephone entry systems. On-board diagnostic LEDs. Convient manual release in case of power failure Model 412 High Voltage includes:. One 424 MP-B control pannel operates single leaf or bi-parting gates. Choice of 6 operating modes including: - "pulse-to-open, pulse-to-close" - automatic timed closure - man present (separate open and close contacts). 30 VDC power for accessories. 115 or 230 VAC Model 412 Low Voltage includes:. One 424 MP-B control pannel operates single leaf or bi-parting gates. Choice of 2 operating modes including: - "pulse-to-open, pulse-to-close" - automatic timed closure. Slow-down soft stop feature. On-board diagnostic LEDs. Battery back-up included. Solar kit available. 24 VDC (transformer)

UL 325 Class Descriptions & FAAC Operators Class FAAC Models Duty Cycle Typical Use Class 1 Class 2 Class 3 Class 4 Residential 400, 412, 402 Limited vehicular gate 422, 750, 760 duty. Home use Small apartment operator 620, 640, 885 building, up to 4 units per building, limited public access Commercial/General 400, 620, 640 Continuous Apartment buildings access vehicular 885 duty. Open public access gate operator Industrial/Limited 400, 620, 640 Continuous. No public access access vehicular 885 Duty gate operator Restricted Access 620, 640, 885 Continuous. Prison related vehicular gate Duty security operator Duty Cycle The duty cycle achieved by a swing gate operator in terms of "operations per hour" is, in large part, a function of the installation. For example, an operator swinging a leaf through 125 o will be able to complete fewer operations per hour than the same operator swinging only 90 o. The duty cycles listed below reflect performance at an ambient temperature of 72 o F (22 o C) and at normal voltages of 115 or 230 VAC. Changes in environmental conditions, voltage and gate condition will affect achievable duty cycle. FAAC Operator Model Cycles per hour 400 80 402 30 412 50 422 30 750 30 760 30 Specifications Parameter Model 412 Model 412 High Voltage Low Voltage Application Single family residence, single leaf or bi-parting gate (vehicles only, not for pedestrian use) (not recommended for solid gates) Cycles per hour 50 50 Maximum gate 110 degrees 110 degrees swing 90 degree 13 seconds 13 seconds opening time Maximum weight 500 pounds 500 pounds per gate leaf (226.8 kg) (226.8 kg) Maximum length 14 feet (4.2 m) 14 feet (4.2 m) per gate leaf Approx. operating -4 o F to 131 o F (-20 o C to 55 o C) temperature range Mechanical locking Available in opened and closed positions Voltage 115 VAC or Primary: 115 VAC 230 VAC Secondary: 24 VDC (transformer) Note: Operator specifications are approximate. Environmental factors can change the performance of the operator. Your installer will advise you which model of operator will work best for your site and application. Speed and leaf length Some thought should be given to the speed at which the gate will travel. The longer the gate leaf, the faster the traveling edge must move to clear an area in a given amount of time. Model 424 MP-B Control Panel and fiberglass enclosure (cover not shown) A speed of 40 feet/minute (12.2 meters/minute) is a bench mark velocity. It permits efficient operation while limiting the energy in the moving gate leaf. The lower the energy, the less chance of damage to property or injury to people in the event of accidental contact with the moving gate. 11.94 in. (29 cm) 2.375 in. (6 cm) 23.75 in. (60.2 cm) 39.25 in. (99.8 cm) 412 Dimensions 7.5 in. (19.2 cm) 3.75 in. (9.5 cm) 3.75 in. (9.5 cm) Examples illustrating the relationship between operator speed, gate leaf length, and the velocity of the leaf s traveling edge Speed options available (time needed to swing a gate 90 o ) 6 sec. 12 sec. 15 sec. 17 sec. 23 sec. EXAMPLE: Velocity of the traveling edge of an 8 ft (2.4 m) leaf [in feet/m and (meters/m)] 126 fpm (38 mpm) 63 fpm (19 mpm) 50 fpm (15 mpm) 44 fpm (14 mpm) 33 fpm (10 mpm) Longest leaf which can be used if the velocity of the traveling edge is not to exceed 40 fpm (12.2 mpm) 2.5 ft (0.8 m) 5 ft (1.5 m) 6 ft (1.9 m) 7.5 ft (2.3 m) 10 ft (3 m)

Model 412 Mounting Geometry Sometimes the mounting measurements will result in a flush mounting. Other applications require a column to be notched in order to accommodate the correct mounting geometry. Note: If, in your installation, notching a column is not practical, other solutions are available:. Install operators using an outward swing.. Upgrade to an operator with more mounting flexibility.. Use a Pantograph.. Use an in-ground operator. Notched column How many degrees of swing are required?. One FAAC gate operator (Model 750) can swing a gate up to 180 o.. All models of FAAC operators can swing a gate at least 90 o.. Openings which require swings greater than 90 o will need certain FAAC operator models.. The swing of an operator applies equally to inward or outward swinging gates. 90 o Flush mounting Notched mounting Decisions regarding mounting geometry apply to gate mounted operators: Models 400, 402, 422 and 412. As shown in the diagrams below, the operators must be mounted at an angle to the gate. Correct mounting geometry assures that the desired degrees of swing are achieved, that the gate speed is correct, and that the operator and gate will operate properly and have a long life. All FAAC operators: Models 412, 402, 422, 400, 750, 760 Mounting dimensions for OUTWARD-swinging 412 operators, top view Measurement a 90 Swing 110 Swing A 5.75 in. (14.5 cm) 4.88 in. (12.5 cm) B 5.75 in. (14.5 cm) 4.88 in. (12.5 cm) WARNING! A and B should differ by no more than.5 in. (1.27 cm). Larger differences may dangerously alter the speed of operation. C 24.25 in. (62 cm) D 4 in. (10 cm) 3.13 in. (8 cm) E Absolute minimum of 3.13 in. (8 cm) F Absolute minimum of 1.75 in. (4.5 cm) 110 o Models 412, 400, 750, 760. a Gate speed increases as the dimensions A and B decrease. The torque adjustment may also affect the gate speed. b The sum of A and B must equal a minimum of 3.625 in. (9 cm). Gate post (or column) Axis of rotation for gate leaf Centerline of gate leaf 115 o Models 400, 750, 760. Steel elbow Mounting dimensions for INWARD-swinging 412 operators, top view Measurement a 90 Swing 110 Swing A 5.75 in. (14.5 cm) 4.88 in. (12.5 cm) B 5.75 in. (14.5 cm) 4.88 in. (12.5 cm) WARNING! A and B should differ by no more than.5 in. (1.27 cm). Larger differences may dangerously alter the speed of operation. C 35.125 in. (89.2 cm) D 4 in. (10 cm) 3.13 in. (8 cm) E 3.13 in. (8 cm) 3.13 in. (8 cm) F Absolute minimum of 1.75 in. (4.5 cm) a Gate speed increases as the dimensions A and B decrease. The torque adjustment may also affect the gate speed. b The sum of A and B must equal a minimum of 3.625 in. (9 cm). Gate post (or column) Axis of rotation for gate leaf Centerline of gate leaf 125 o 140 o Models 400 EG (extended geometry), 750, 760. Models 750 (up to 180 o ), 760 (up to 148 o with soft stop )

HEADQUARTERS Bologna, Italy FAAC s U.S. headquarters in Cheyenne, RESEARCH & DEVELOPMENT Bologna, Italy Dublin, Ireland Wyoming PRODUCTION FACILITIES Bologna, Italy Founded in 1965, FAAC has risen to become the world s largest specialized manufacturer SUBSIDIARY OFFICES Wals-Siezenheim, Austria Corbas-Lyon, France Freilassing, Germany Alcobendas-Madrid, Spain Illnau, Switzerland Basingstoke, Hampshire, U.K. Cheyenne, Wyoming, U.S.A. of automated operators for swing, slide and barrier gate systems. International company headquarters, research & development and primary production facilities are located in Bologna, Italy. Dublin, Ireland is the site of FAAC s research, design and production facility for electronic controls including photocells, radio controls and code opening systems. INTERNATIONAL, INC. FAAC is an ISO 9001 Certified Company FAAC International, Inc. 303 Lexington Avenue Cheyenne, WY 82007 1-800-221-8278 Fax: (307) 632-8148 Web: www.faacusa.com LIT-412REV-03/02