Bullet Valve (BV) Series

Similar documents
Bullet Valve (BV) Series

BULLET VALVE THINK GLOBAL ACT LOCAL. Our global distribution network is keeping your machines running around the clock around the world

82 Series MAConnect with Sub-D

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

92 Series MAConnect with Sub D

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

GM - G XXX-XXX. Direct solenoid and solenoid pilot operated valves. Function Port size Flow [Max] Individual mounting. Series 77

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Introduction Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Section 2 Proportional Quick Exhaust

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices. Orifice plate with annular chambers. 4/358 Siemens FI

B SERIES. Bulletin B-2017

Technical Bulletin. MAC Valves, Inc., is pleased to announce. Introduction - Plunger up / Plunger Cooling / Counterblow Solutions

Specifications 54 Series Valve

Table 1d - FSA for All Returns, Females Tax Year

CFR Series. Power Inductors OUTLINE FEATURES APPLICATIONS SPECIFICATIONS MITSUMI

33 SERIES 34 SERIES 34B/C - X X X - G XX X - X XX A - X X X - R XX X - X XX

Bulletin H-Tech 03 High Pressure Valves Series H

42 Series MAConnect TM. 42 Series Plug-In Manifold

MAC VALVES EUROPE, INC.

SERIES RTC RODLESS CYLINDERS PNEUMATIC SHUTTLE TYPE

Introduction Section 1 Section 2 Section 3

MAC Pulse Valve PV06 Series

MAC Pulse Valve PV03 Series

C Linear Positioner (Small)

S Series Technical Data...7 How to Order...8 Dimensions...8 Manifold Dimensions and Part Numbers...9

Complete Range of Movement Solutions

SERIES 740 VALVES PNEUMATIC DIRECTIONAL CONTROL

Quality Since 1980 SERVICE GUIDE. Eliminator Series HD, HDL, HDR, SD EDrive Actuators, Inc. #FB6070 Linear Actuators

Pneutronics. Miniature Proportional Valves. Catalog PND-MPV-001/US January 2007

The Price Alternative Pneumatic Cylinders and Slides

Miniature Valves MH1. Extremely small, fast and versatile. Info 206

GPM PSI LPM BAR MODEL CAVITY PAGE IF-S3A special IF-S3D special IG-S4A special 198

Technical Data Sheet SEVO 1230 Clean Agent Cylinders

KRONES DIRECT REPLACEMENTS

Ports. Dr. Breit GmbH Carl-Zeiss-Straße 25 D Heiligenhaus phone-contact:

SUPERSPOOL II VALVE PNEUMATIC DIRECTIONAL CONTROL VALVE SERVICE INFORMATION

Series OCG Pneumatic Cylinders

kysimply Unique Unique 7000 Series Y-Body

Miniature Inert PTFE Isolation Valves. Physical Properties Electrical Performance Characteristics

Quality Since 1980 SERVICE GUIDE. VecTac VT EDrive Actuators, Inc. #FB6060 Linear Actuators

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

32, CONTENTS SMALL LARGE

Balanced Valve Series Multi-Purpose Direct-Acting Solenoid Valves

CATALOG FL-16-B THE LIGHT-WEIGHT LINE WITH HEAVY-DUTY FEATURES

Series OCG Pneumatic Cylinders

3/8 & 1/2 NPT. 4-Way - 5 Ported - 2 Position - Type 2 Use on all 4 Way - 2 Position applications

Flow Control Valve Instruction Manual

TABLE OF CONTENTS CYLINDER FEATURES MOUNTING STYLES DOUBLE-ACTING Series T and TS 4 DOUBLE-ACTING DOUBLE-ENDED Series TDE and TSDE 4 MAGNETIC SWITCH D

Manifold w/ Needle Valve Instruction Manual

Global Gear Products. Brochure. SAE A-Aluminum (Group 2)

Miniature Multimedia Valves

Technical Data... 3 How to Order... 4 Dimensions... 5 Inline Mount Valve... 6 Manifold Dimensions and Part Numbers... 6

EtherNet/IP EtherCAT POWERLINK PROFINET Modbus/TCP

Series 11 Miniature Pneumatic Solenoid Valve 15mm Solenoid Valve

External Pilot Models 5 Sgl. Sol. Plug-In to Left. Internal Pilot Models 1 Sgl. Sol. Plug-In to Left. 4 Dbl. Sol. Plug-In to Right

Vickers. Proportional Valves. EPV10 Series. Proportional Flow Controls. Released 6/95

SITRANS P measuring instruments for pressure

Optimized for OEM requirements at a lower price.

USER MANUAL. NEMA 48C Flange Mounted, Enclosed, Clutch Brake. FMCBE Model 500 FORM NO. L A (i)

CONDENSED CATALOG CC

Warnings and Cautions

Colorflow and Ball Valves. Industrial Flow Control, Check, Gauge Control. Catalog HY /US

2. COMPACT CYLINDERS series STRONG (RS, RQ)

FITTINGS CHEST FITTINGS CHEST. Get organized with the Pneuforce Fittings Chest!

Gauge Adapter Instruction Manual

Rodless cylinders. Standard magnetic version. High reliability and long lifetime. Low friction and good resistance to loads

2/2-way, 3/2-way NC and NO. Monostable - bistable (with magnetic memory) Ports M5 and G1/8 - cartridge ø4

M-61-F. Fixed Set Point Flow Switch. Description. Operating Principle. Application Examples.

Service and Parts Manual. Minimum Filtration Required:

QB4 PRESSURE CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS

Proportional Valves. Proportional solenoid valves for pressure and flow control

Val-U-Act Ball Valve Operators. Air-Oil Systems, Inc.

Models & Inch & 4 Inch Digital Inline Pressure Control Valves SM64504

Miniature Pneumatic Solenoid Valve

Mini 1. Compact High Flow 3-Way and 4-Way Pneumatic Directional Control Valves

TPCA Power Clamps Catalog

Assembly Instructions for H- and B Guide with Linear Motor

3 Inch & 4 Inch Digital Bypass Pressure Control Valves

SOLENOID VALVES AND PNEUMATIC VALVES

Easytork Solenoid Valve IOM

TYPE S RELAY VALVE (Volume booster) Service Manual

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

SERIES C TYPE VALVES C3 VALVES Port Sizes: Four-Way 5/ UNF or M5 Pneumatic-vacuum to 115 psi (8 bar) (individual valves) Gang mounting (2 or mo

SRX R. Remediation Pumps. Simply Reliable

PNEUMATIC PIPING DEVICES Service Information

ORIGINAL INSTRUCTIONS G715A. Pneumatic-hydraulic Riveter E. Warner Ave Santa Ana, CA

Line-Mounted Valves L Series. L1 / L2 Series Overview L22 BA4 52. Valve Function. Function PP6 = PP7 = JA4* = JJ4* = JJ5* = JJ6* = JJ7* =

GROUP 11 HYD. PUMPS & VALVES

Transcription:

BULLET Valve

Bullet Valve (BV) Series The Bullet Valve represents yet another evolution in air valve technology from MAC. VERY FEW PARTS LONG LIFE LIFTING SOLENOID ONE PIECE POPPET / ARMATURE (Patents Pending) BALANCED DESIGN SOLENOID ISOLATED FROM CONTAMINATED AIR UNIQUE MOUNTING The threaded cartridge configuration allows for a variety of mounting possibilities, such as direct integration into pneumatic actuators or vacuum generators without the need of external tubing or fasteners. 2-way & 3-way models of the BV cartridge (9mm & 10mm dia.) are available. A surface manifold mount configuration is also offered. D-SEAL TECHNOLOGY Minimum Friction Wiping Action Isolates Solenoid From Contaminated Air LONG LIFE LIFTING SOLENOID SHORT STROKE - High Shifting Forces (Energized) OVERSTROKE - Built In Wear Compensation STRONG RETURN SPRING High Shifting Forces ONE PIECE POPPET/ARMATURE (De-energized) (Patents ts Pending) ng) Balanced & Repeatable Cushioning - Alleviates Solenoid Wear Valves That Don t Stick

Function Flow [max] Manifold mounting Series 2/2 Up to 0.08 Cv Cartridge BV210A OPERATIONAL BENEFITS 1. Short stroke with high shifting forces 2. Balanced poppet, immune to pressure fl uctuations 3. Precise repeatability 4. Solenoid isolated from contaminated air 5. Very few parts 6. Extremely long life 7. Unique mounting - no fasteners or screws required HOW TO ORDER HOW TO ORDER VALVE Type 2 Way Cartridge BV210A-CA1-00-xxxx-xxx SOLENOID OPERATOR X XX X - X XX Solenoid Voltage Lead wire length B Round EH 24VDC (2.5W) EG 24VDC (4.0W) EK VDC (2.5W) EJ VDC (4.0W) * High wattage - high speed options - consult factory ** ERC wattage reduction options - consult factory HOW TO ORDER CIRCUIT BAR 0 No lead wire A 18 B 24 C 36 D 48 E 72 F 96 H 144 Solenoid can (round) C For Top Cover Option and Can w/ Outer Threads Solenoid cover JST Connector Flying Leads TA No ground wire BA TC Blocking & suppr. BC diode & LED TE Blocking & suppr. BE diode TG LED BG TJ MOV BJ TL LED & MOV BL Port size Spacing (mm) Side cylinder port # 10-32 UNF M5 M7 CCMV10A-00AAA-xx CCMV10A-00AAB-xx CCMV10A-00AAC-xx xx = Number of stations Note: for valves mounted to bar at factory, add -9 to model number. * High wattage confi gurations require intermittent duty cycles. ** ERC - Energy Reduction Circuitry - Reduces the effective wattage at continuous duty

TECHNICAL DATA Fluid: Pressure range: Lubrication: Filtration: Flow (at 6 bar ΔP=1bar): Voltage range: Compressed air, vacuum, inert gases Vacuum to 0 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 210 F) 40μ Up to 0.08 Cv -15% to +10% of nominal voltage Tools: Manifold cavity step reamer: T-6960 Insertion/removal socket: AT-1181 DIMENSIONS Bullet Valve with JST Cover and Circuit Board for LED., MOV., & Diode Options BV210A (2-way) - Standard Watt 54.7 11.7DIA. 14.00.00 STATION SPACING CYL. CCMV10A - Side Ports BV210A SIDE PORTS "A" 28.0 CYL. DIMENSION "A" #10-32 17.90 59.0 M5x0.8 M7x1.0 17.90 19.25 "P" INDICATES B.S.P.PL. "T" INDICATES B.S.P.TR. 27.00 20.0 76.0 4.25 67.5 10.5 7.9 36.0 28.1 4.25DIA. - THRU (2) STATION #1 1/8"-27 N.P.T.F. OR 1/8"-28 B.S.P.PL. OR 1/8"-28 B.S.P.TR. (4) (2) EACH SIDE

Function Flow [max] Manifold mounting Series 3/2 NC, Universal Up to 0.08 Cv Cartridge BV310A OPERATIONAL BENEFITS 1. Short stroke with high shifting forces 2. Balanced poppet, immune to pressure fl uctuations 3. Precise repeatability 4. Solenoid isolated from contaminated air 5. Very few parts 6. Extremely long life 7. Unique mounting - no fasteners or screws required HOW TO ORDER HOW TO ORDER VALVE Type 3 Way N.C. 3 Way Universal 2 2 Cartridge SOLENOID OPERATOR 3 1 BV310A-CC1-00-xxxx-xxx X XX X - X XX 3 1 BV310A-CD1-00-xxxx-xxx Solenoid Voltage Lead wire length B Round HA 24VDC (1.0W) HB 24VDC (1.8W) HC 24VDC (2.5W) HD 24VDC (3.0W) HE 24VDC (4.0W) HF VDC (1.0W) HG VDC (1.8W) HH VDC (2.5W) HJ VDC (3.0W) HK VDC (4.0W) * High wattage - high speed options - consult factory ** ERC wattage reduction options - consult factory 0 No lead wire A 18 B 24 C 36 D 48 E 72 F 96 H 144 C Solenoid can (round) For Top Cover Option and Can w/ Outer Threads Solenoid cover JST Connector Flying Leads TA No ground wire BA TC Blocking & suppr. BC diode & LED TE Blocking & suppr. BE diode TG LED BG TJ MOV BJ TL LED & MOV BL * M8 (pico) connector - Consult factory HOW TO ORDER CIRCUIT BAR Port size Spacing (mm) Side cylinder port # 10-32 UNF M5 M7 CCMV10A-00ABA-xx CCMV10A-00ABB-xx CCMV10A-00ABC-xx xx = Number of stations Note: for valves mounted to bar at factory, add -9 to model number. * High wattage confi gurations require intermittent duty cycles. ** ERC - Energy Reduction Circuitry - Reduces the effective wattage at continuous duty.

TECHNICAL DATA Fluid: Pressure range: Lubrication: Filtration: Flow (at 6 bar ΔP=1bar): Voltage range: Compressed air, vacuum, inert gases Vacuum to 0 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 210 F) 40μ Up to 0.08 Cv -15% to +10% of nominal voltage Tools: Manifold cavity step reamer: T-6963 Insertion/removal socket: AT-1181 DIMENSIONS Bullet Valve with JST Cover and Circuit Board for LED., MOV., & Diode Options BV310A (3-way) - Standard Watt 59.2 11.7DIA. 4.25 67.5 CCMV10A - Side Ports 20.0 "P" INDICATES B.S.P.PL. "T" INDICATES B.S.P.TR. 10.5 7.9 18.0 36.0 28.1 4.25DIA. - THRU (2) 76.0 STATION #1 1/8"-27 N.P.T.F. OR 1/8"-28 B.S.P.PL. OR 1/8"-28 B.S.P.TR (4) (2) EACH SIDE 60.8 CYL #10-32 M5 X 0.8 M7 X 1.0 DIMENSION "A" 13.0 13.0 11.5 28.0 "A" BV310A SIDE PORTS 14.0.0 STATION SPACING CYL

Function Flow [max] Manifold mounting Series 3/2 NC, Universal Up to 0.08 Cv Manifold mount - Non plug-in BV310A OPERATIONAL BENEFITS 1. Short stroke with high shifting forces 2. Balanced poppet, immune to pressure fl uctuations 3. Precise repeatability 4. Solenoid isolated from contaminated air 5. Very few parts 6. Extremely long life HOW TO ORDER HOW TO ORDER VALVE Type 3 Way N.C. 3 Way Universal 2 2 Manifold Mount - Non plug-in SOLENOID OPERATOR 3 1 BV310A-LC1-00-xxxx-xxx X XX X - X XX 3 1 BV310A-LD1-00-xxxx-xxx Solenoid Voltage Lead wire length B Round HA 24VDC (1.0W) HB 24VDC (1.8W) HC 24VDC (2.5W) HD 24VDC (3.0W) HE 24VDC (4.0W) HF VDC (1.0W) HG VDC (1.8W) HH VDC (2.5W) HJ VDC (3.0W) HK VDC (4.0W) * High wattage - high speed options - consult factory ** ERC wattage reduction options - consult factory 0 No lead wire A 18 B 24 C 36 D 48 E 72 F 96 H 144 Solenoid can (round) Solenoid cover B Cover For JST Connector Flying Leads Manifold Body TA No ground wire BA TC Blocking & suppr. BC diode & LED TE Blocking & suppr. BE diode TG LED BG TJ MOV BJ TL LED & MOV BL * M8 (pico) connector - Consult factory HOW TO ORDER NON PLUG-IN CIRCUIT BAR Port size Spacing (mm) Side cylinder port Bottom cylinder port # 10-32 UNF M5 M7 CBMV10A-00ABA-xx CBMV10A-00ABB-xx CBMV10A-00ABC-xx xx = Number of stations Note: for valves mounted to bar at factory, add -9 to model number. CBMV10A-00BBA-xx CBMV10A-00BBB-xx CBMV10A-00BBC-xx OPTIONS BV310A- LC 1-00-xxxx-xxx Replace with 0 for no manual operator * High wattage confi gurations require intermittent duty cycles **ERC - Energy Reduction Circuitry - Reduces the effectiveness wattage at continuous duty How to order bar configured for regulator CBMV10A-00 A BB- xx Replace with D for regulator - Side ports Replace with E for regulator - Bottom ports Note: Regulator must be ordered separately - see back

TECHNICAL DATA Fluid: Pressure range: Lubrication: Filtration: Flow (at 6 bar ΔP=1bar): Voltage range: Spare parts: Compressed air, vacuum, inert gases Vacuum to 0 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 210 F) 40μ Up to 0.08 Cv -15% to +10% of nominal voltage Pressure seal, body to base: 16985 Mounting screw, body to base: 35166-2 pcs required Regulator for bar: PR44A-A0AX X = A 0 to 100 PSI B 0 to 60 PSI C 0 to 40 PSI D 0 to 15 PSI DIMENSIONS 61.4 BV310A Bar Manifold Assembly.0 BV310A-LCX-00-BXX-0YZZ Without regulator CBMV10A Circuit bar for BV310 11.5 With regulator 70.3 100.3 34.0 (2) 70.0 4.3 "YY" (2) 40.0 4.3 (2) "ZZ" 16.0.0 VALVE SPACING 32.0 4.3 72.5 (5) STATIONS ADD OR SUBRACT.0 PER STATION 4.25DIA. - THRU (2) 81.0 (5) STATIONS ADD OR SUBRACT.0 PER STATION 20.0 40.0.0 16.0 #10-32, M5, & M7 SIDE CYLINDER PORTS 13.1.0 #10-32, M5 OR M7 CYLINDER PORTS 8.0 28.0

Function Flow [max] Manifold mounting Series 2/2 Up to 0.07 Cv Cartridge BV209A OPERATIONAL BENEFITS 1. Short stroke with high shifting forces 2. Balanced poppet, immune to pressure fl uctuations 3. Precise repeatability 4. Solenoid isolated from contaminated air 5. Very few parts 6. Extremely long life 7. Unique mounting - no fasteners or screws required HOW TO ORDER HOW TO ORDER VALVE Type 2 Way Cartridge BV209A-CA1-00-xxxx-xxx SOLENOID OPERATOR X XX X - X XX Solenoid Voltage Lead wire length B Round GC 24VDC (2.5W) GE 24VDC (4.0W) GH VDC (2.5W) GK VDC (4.0W) * High wattage - high speed options - consult factory ** ERC wattage reduction options - consult factory HOW TO ORDER CIRCUIT BAR 0 No lead wire A 18 B 24 C 36 D 48 E 72 F 96 H 144 C Solenoid can (round) For Top Cover Option and Can w/ Outer Threads Solenoid cover JST Connector Flying Leads TA No ground wire BA TC Blocking & suppr. BC diode & LED TE Blocking & suppr. BE diode TG LED BG TJ MOV BJ TL LED & MOV BL * M8 (pico) connector - Consult factory Port size Spacing (mm) Side cylinder port # 10-32 UNF M5 M7 11 11 11 CCMV09A-00AAA-xx CCMV09A-00AAB-xx CCMV09A-00AAC-xx xx = Number of stations Note: for valves mounted to bar at factory, add -9 to model number. * High wattage confi gurations require intermittent duty cycles. ** ERC - Energy Reduction Circuitry - Reduces the effective wattage at continuous duty

TECHNICAL DATA Fluid: Pressure range: Lubrication: Filtration: Flow (at 6 bar ΔP=1bar): Voltage range: Compressed air, vacuum, inert gases Vacuum to 0 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 210 F) 40μ Up to 0.07 Cv -15% to +10% of nominal voltage Tools: Manifold cavity step reamer: T-6961 Insertion/removal socket: AT-1180 DIMENSIONS Bullet Valve with JST Cover and Circuit Board for LED., MOV., & Diode Options BV209A (2-way) - Standard Watt 44.5 10.5DIA. 72.0 CCMV09A - Side ports 4.25 63.5 "P" INDICATES B.S.P.PL "T" INDICATES B.S.P.TR. 10.5 7.9 18.0 36.0 1/8"-27 N.P.T.F. OR 1/8"-28 B.S.P.PL. OR 1/8"-28 B.S.P.TR. 4.25DIA. - THRU (2) (1) EACH SIDE (2) STATION #1 BV209A SIDE PORTS 52.7 CYL. #10-32 DIMENSION "A" 17.20 23.5 "A" M5x0.8 17.20 M7x1.0 17.20 14.00 11.00 STATION SPACING CYL.

Function Flow [max] Manifold mounting Series 3/2 NC, Universal Up to 0.06 Cv Cartridge BV309A OPERATIONAL BENEFITS 1. Short stroke with high shifting forces 2. Balanced poppet, immune to pressure fl uctuations 3. Precise repeatability 4. Solenoid isolated from contaminated air 5. Very few parts 6. Extremely long life 7. Unique mounting - no fasteners or screws required HOW TO ORDER HOW TO ORDER VALVE Type 3 Way N.C. 3 Way Universal 2 2 Cartridge SOLENOID OPERATOR 3 1 BV309A-CC1-00-xxxx-xxx X XX X - X XX 3 1 BV309A-CD1-00-xxxx-xxx Solenoid Voltage Lead wire length B Round GA 24VDC (1.0W) GB 24VDC (1.8W) GC 24VDC (2.5W) GD 24VDC (3.0W) GE 24VDC (4.0W) GF VDC (1.0W) GG VDC (1.8W) GH VDC (2.5W) GJ VDC (3.0W) GK VDC (4.0W) * High wattage - high speed options - consult factory ** ERC wattage reduction options - consult factory 0 No lead wire A 18 B 24 C 36 D 48 E 72 F 96 H 144 C Solenoid can (round) For Top Cover Option and Can w/ Outer Threads Solenoid cover JST Connector Flying Leads TA No ground wire BA TC Blocking & suppr. BC diode & LED TE Blocking & suppr. BE diode TG LED BG TJ MOV BJ TL LED & MOV BL * M8 (pico) connector - Consult factory HOW TO ORDER CIRCUIT BAR Port size Spacing (mm) Side cylinder port # 10-32 UNF M5 M7 11 11 11 CCMV09A-00ABA-xx CCMV09A-00ABB-xx CCMV09A-00ABC-xx xx = Number of stations Note: for valves mounted to bar at factory, add -9 to model number. * High wattage confi gurations require intermittent duty cycles. ** ERC - Energy Reduction Circuitry - Reduces the effective wattage at continuous duty.

TECHNICAL DATA Fluid: Pressure range: Lubrication: Filtration: Flow (at 6 bar ΔP=1bar): Voltage range: Compressed air, vacuum, inert gases Vacuum to 0 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 210 F) 40μ Up to 0.06 Cv -15% to +10% of nominal voltage Tools: Manifold cavity step reamer: T-6962 Insertion/removal socket: AT-1180 DIMENSIONS Bullet Valve with JST Cover and Circuit Board for LED., MOV., & Diode Options BV309A (3-way) - Standard Watt 44.5 10.5DIA. "A" 14.00 11.00 STATION SPACING CCMV09A - Side ports CYL BV309A SIDE PORTS 28.0 59.0 CYL #10-32 M5 X 0.8 M7 X 1.0 DIMENSION "A" 17.4 17.4 18.9 4.25 72.0 63.5 "P" INDICATES B.S.P.PL. "T" INDICATES B.S.P.TR. 20.0 10.5 7.9 36.0 18.0 28.1 4.25DIA. - THRU (2) STATION #1 1/8"-27 N.P.T.F. OR 1/8"-28 B.S.P.PL. OR 1/8"-28 B.S.P.TR. (4) (2) EACH SIDE

CARTRIDGE MODIFICATIONS Our manufacturing process of the Bullet Valve cartridge body enables fl exibility with regards to offering potential modifi cations to meet your specifi c application needs. An example of such modifi cations is the axial fl ow modifi cation we are currently offering for the BV210 series. The axial fl ow cartridge enables the valve to fl ow air between the bottom of the valve body and manifold it is housed in see fi gure below. This modifi cation allows for a linear fl ow path out of the manifold producing measurably higher outlet pulse height (force) in blow off type of applications. We have currently used this modifi cation for applications in the sorting industry with excellent results. If you have an application that would benefi t from utilizing the axial fl ow cartridge option or wish to discuss other potential cartridge modifi cations, please consult your local MAC distributor (MDN Associate). By understanding your application and valve requirements we can optimize the valve settings accordingly.

Notes

PRECAUTIONS AND WARNINGS CONCERNING THE APPLICATION, INSTALLATION AND SERVICE OF MAC VALVES AND OTHER MAC VALVES PRODUCTS The warnings and precautions below are important to be read and understood before designing into a system any MAC Valves products, and before installing or servicing any MAC Valves product. Improper use, installation or servicing of any MAC Valves product in some systems could create a hazard to personnel or equipment. No distinction in importance should be made between the terms warnings and precautions. WARNING :. Under no circumstances are MAC Valves products to be used in any application or in any manner where failure of the MAC Valves product to operate as intended could in any way jeopardize the safety of the operator or any other person or property. temperature range. valve. sheet, or factory for proper maintenance procedures, lubrication and cleaning agents. Never attempt to repair or perform other maintenance with air pressure to the valve. APPLICATION PRECAUTIONS :. They are general purpose industrial products with literally thousands of different applications in industrial systems. These products are not inherently dangerous, but they are only a component of an overall system. The system in which they are used must provide adequate safeguards to prevent injury or damage in the event failure occurs, whether it be failure of switches, regulators, cylinders, valves or any other component. for such use. there will always be a flow path from the inlet to one of the outlets regardless of which of the two positions the valve is situated. Therefore, if pressurized air retained in the system would present a hazard in the application or servicing of the valve or system, a separate method in the system must be provided to remove the trapped air. remote air operated. valve moves to a center position. Listed below are the various center position functions : the air at both outlet ports is trapped. If trapping the air in both outlet ports would present a hazard in the application or servicing, a separate method in the system must be provided to remove the trapped air or this type valve should not be used. hazard in the application or servicing, this type valve should not be used. the valve. If having pressurized air to either or both outlet ports would present a hazard in the application or servicing of the valve or system, a separate method in the system must be provided to remove the retained air or this type valve should not be used. MAC Valves products are to be installed only on applications that meet all operating specifications described in the MAC catalog for the MAC Valves product. Most MAC valves can be ordered with manual operators. Manual operators when depressed, are designed to shift the valve to the same position as would the corresponding solenoid or remote air physical location of the manual operator in the system. If intentional or accidental operation of a valve by a manual operator could cause personal injury or property damage, a manual operator should not be used. INSTALLATION PRECAUTIONS :. electricity to the machine. and operations are thoroughly understood. C. If air line lubrication is used do not use any lubrication other than those recommended in the SERVICE PRECAUTIONS : is retained in the system. and used and whether there is air retained in the connecting lines to the valve or electric power still connected to the valve. operation sheet, or factory for proper maintenance procedures, lubrication and cleaning agents. Never attempt to repair or perform other maintenance with air pressure to the valve. of a manual operator on the valve could result in personal injury or property damage. LIMITATION OF GUARANTEE. This Guarantee is limited to the replacement or rebuilding of any valve or other product which should guarantee as provided under the Flat Rate Rebuild Program.. No claims for labor, material, time, damage, or transportation are allowable nor will any valve or other product be replaced or rebuilt under this guarantee which has been damaged by the purchaser not in the normal course of its use and maintenance during the warranty period. The guarantee does not beyond the control of MAC Valves,Inc. MAC Valves, Inc. shall in no event be liable for remote, special or consequential damages under the MAC Guarantee, nor under any implied warranties, including the implied warranty of merchantability. Valves, Inc. organization to assure our customer long, and continued satisfaction. www.macvalves.com

THINK GLOBAL ACT LOCAL Our global distribution network is keeping your machines running around the clock around the world MAC VALVES, INC. P.O. BOX 111 30569 BECK ROAD WIXOM, MI 48393-7011 MAC VALVES, INC. 5555 ANN ARBOR ROAD DUNDEE, MI 48131 TEL: 1-800-MAC VLVS TEL: 1 (248) 624-7700 FAX: 1 (248) 624-0549 www.macvalves.com mac@macvalves.com TEL: 1 (734) 529-5099 FAX: 1 (248) 863-2959 MAC VALVES EUROPE, INC. RUE MARIE CURIE, B- 4431 ANS (LIEGE) BELGIUM TEL: 32 (4) 239 68 68 FAX: 32 (4) 263 19 42 info@macvalves.be MAC VALVES ASIA, INC. NO. 45, DONGYUAN ROAD JHONGLI CITY, TAOYUAN COUNTY TAIWAN TEL: 886 (3) 463-6868 FAX: 886 (3) 463-4576 mva@macasia.com.tw MAC VALVES PACIFIC, INC. P.O. BOX 221 PENROSE, AUCKLAND NEW ZEALAND TEL: 64 (9) 634-9400 FAX: 64 (9) 634-9401 www.macvalves.co.nz sales@macvalves.co.nz