SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function

Similar documents
FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

SIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for.

SIRCOVER. Manual transfer switches from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Strong points

SIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A, up to 1500 VDC

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

An innovative technology

SIRCO M and MV Universal load break switches from 16 to 160 A

SIRCO PV Load break switches for photovoltaic applications for use up to 1500 VDC from 100 to 3200 A

ATyS t M - ATyS g M Automatic Transfer Switching Equipment from 40 to 160 A

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

What you need to know. Â Conformity to standards

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

Vistop TM isolating switches 63 to 160A

SIRCOVER Manual transfer switching equipment for source changeover applications from 63 to 3200A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

CATALOGUE MARINE APPLICATIONS. Energy performance solutions

General Characteristics

sirco-ul_004_b_cat 100A to 2000A - 600VDC and 1000VDC UL98B Listed

DPX moulded case circuit breakers

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

Safety enclosures Normal atmospheres steel enclosure from 50 to 1600 A

DPX Thermal magnetic and trip-free switches DPX 3 -I 250


DPX Magnetic only

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX earth leakage DPX 3 -I earth leakage

A compact range of Switch-Disconnectors with the capacity to add auxiliary and neutral block options to the basic load break switch block.

3 - Protection components Motor circuit-breakers


ASL09..S 3-pole Contactors - Spring Terminals

MOULDED CASE CIRCUIT BREAKERS BC160N

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

DMX 3 -I 2500 switch disconnectors

MS25, MST25, MS20, MST20

TAE pole Contactors

Essential equipment for all your requirements

DPX Electronic + earth leakage

THE SANTON FCS-TYPE SWITCH DISCONNECT. Superior Switch Solutions

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

SENTRON Switching and Protection Devices Switch Disconnectors

AF40... AF96 3-pole contactors Technical data

cor Long Run Experience

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Contents. Volume 5 Motor Control and Protection CA E December

Wall mounted switchgear

Power protection solutions

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Protection components

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

Switching, control and protection solutions for solar applications

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

Motorised and automatic transfer enclosed switchess

SFS-UFS Single Foot Switches

DPX 1600 Electronic release

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

Low Voltage Products. SwitchLine OT change-over switches 160, 200, 250, 315, 400, 630 and 800 Amps. Catalogue OT7GB 05_09 1SCC301012C0201

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Short form catalogue. Motor protection & control

Technical Information

Technical Information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

BETA Switching Switches and Light Indicators

Series CA5 Contactors

Fuse switch-disconnectors

MCCB Accessories to suit AF

Fuse switch-disconnectors

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Safety enclosures. 482 General Catalogue SOCOMEC. Safety enclosures

DX³ RCCBs - ID 4P up to 100 A

C60H-DC C curve. Catalogue numbers

Phone: Fax: Web: -

Protection Equipment

Overcurrent releases - description, specifications, characteristics specifications specifications description...

Low voltage moulded case circuit breaker EB2

Varius SUMMARY OF MODELS

Technical Information

IP20 degree of protection; IP40 degree of protection after installation in a distribution box

Contactor Types CI 61-98

Transcription:

The solution for Load break switches sdmat_066_a cat > Main switchboard > Distribution panel > Motor load break unction SIDERMT 4 x 630 External front operation SIDERMT are manually operated 3 or 4 pole load break switches with visible breaking and a remote tripping function. They make and break under load conditions and provide safety isolation for any low voltage circuit. The tripping function assures the following: - protection of persons against insulation faults through combination with toroids and differential relays - protection against overloads through combination with CTs and thermal relays - protection against short circuits with fuses (see "SIDERMT fuse-combination switches" page 36). Strong points > Remote tripping > Safety with visible double breaking > Robustness in harsh conditions Something to think about > SIDERMT combination: Manually operated fuse switches which can be tripped remotely. dvantages Remote tripping Disconnection by a shunt trip device enables the power to the installation to be switched off with a remote pushbutton. unctional diagram or more details, please see the installation instructions supplied with the product. 5 Safety with visible double breaking SIDERMTs are visible double breaking devices (quadruple up to 800 ) providing real and secure display. Robustness in harsh conditions By lowering the current via a limiting resistor, a SIDERMT fitted with an undervoltage coil may be used in continuous processes or exposed to high ambient temperatures. 4 3 sdmat_063_b_2_x_cat 2. Direct front operation 2. External front operation 3. NO/NC auxiliary contact for each position 4. NO/NC auxiliary contact with shunt trip coil control (standard) 5. shrouds 94 General Catalogue 207-208

References ront operation - Switch body with a shunt trip coil 230 VC Rating () 250 400 630 800 250 600 800 () Standard. (2) Top/bottom. No. of poles Switch body Direct handle 3500 3026 3500 4026 3500 304 3500 404 3500 3064 External handle S3 type Red/Yellow I55 432 35 Shaft for external handle uxiliary contact position 3999 005 2 nd contact NO/NC 3999 0052 uxiliary contact tripping shrouds 3998 3040 (2) 3998 4040 (2) 3500 4064 S3 type Black I55 st contact 3500 308 43 35 Black () 200 mm NO/NC contact 40 520 NO/NC 3999 6203 320 mm 3500 408 40 532 () 3999 003 3500 32 3500 42 3500 36 3500 46 3500 380 3500 480 3998 3063 (2) 3998 4063 (2) screens 2998 320 (2) 2998 420 (2) Inter phase barrier 2998 0003 2998 0004 included Side operation - Switch body with a shunt trip coil 230 VC Rating () 250 400 630 800 250 600 800 () Standard. (2) Top/bottom. No. of poles Switch body Direct handle 3505 3026 3505 4026 3505 304 3505 404 3505 3064 3505 4064 Black 3999 602 () Red 3505 32 3999 603 3505 42 3505 36 3505 46 3505 380 3505 480 External handle Shaft for external handle uxiliary contact position uxiliary contact tripping shrouds 3998 3040 (2) S3 type 3998 4040 (2) Black I55 st contact 435 35 () NO/NC 3505 308 contact 200 mm 3999 005 3998 3063 (2) NO/NC 3505 408 403 520 2 S3 type nd contact 3999 003 3998 4063 (2) NO/NC Red 3999 0052 I55 436 35 screens 2998 320 (2) 2998 420 (2) Inter phase barrier 2998 0003 2998 0004 included General Catalogue 207-208 95

ccessories External operation handle or front operation Rating () Handle type Handle colour External I () Reference 250... 800 S3 Black I55 43 35 (2) 250... 800 S3 Red / Yellow I55 432 35 () I: protection degree according to IEC 60529. (2) Standard. or side operation Rating () Handle type Handle colour External I () Reference 250... 800 S3 Black I55 435 35 (2) 250... 800 S3 Red I55 436 35 () I: protection degree according to IEC 60529. (2) Standard. Direct operation handle Handle type S3 acces_5_a_2_cat acces_66_a_2_cat or front operation Rating () Handle colour Reference 250... 800 Black 3999 6203 or side operation Rating () Handle colour Reference 250... 800 Black 3999 602 acces_56_a_2_cat lternative colour Type S handle cover or single lever S3 type handles. Other colours: please contact us. Colour To be ordered in multiples of Handle type Reference Light grey 50 S3 40 000 Dark grey 50 S3 40 00 acces_98_a_2_cat Type S handle adapter Enables S-type handles to be fitted in place of existing older style Socomec handles. Dimensions dds 2 mm to the handle depth. Handle colour To be ordered in multiples of External I () Reference Black I65 493 0000 () I: protection degree according to IEC 60529. acces_87_a cat Shaft for external operation Standard lengths: Other lengths: please contact us. - 200 mm, - 320 mm. or front operation Rating () Dimension (mm) Shaft length (mm) Reference 250 630 275 439 200 mm 40 520 250 630 275 559 320 mm 40 532 () 800 296 460 200 mm 40 520 800 296 580 320 mm 40 532 () 250 800 29 455 200 mm 40 520 250 800 29 575 320 mm 40 532 () () Standard. or side operation Rating () Dimension Y (mm) Shaft length (mm) Reference 800... 800 0... 279 200 403 520 acces_202_a x_cat Y acces_44_b cat acces_203_a x_cat 96 General Catalogue 207-208

Tripping coil Omnipolar breaking remotely controlled by a shunt trip or undervoltage release coil. Note:the shunt trip coil must not be supplied for more than 5s. 230 VC shunt trip coil is fitted as standard to the switch body. To have an alternative coil, one of the references below must be ordered with the switch. Examples of ordering SIDERMT with 230 VC shunt trip coil - part number: SIDERMT 250, 3-pole, front operation: 3500 3026. SIDERMT with other coil type or voltage - 2 part numbers: SIDERMT 250, 3-pole, front operation, with undervoltage trip coil 0 VC: 3500 3026 + 399 30. Shunt trip coil acces_049_a cat Undervoltage trip coil acces_050_a cat Characteristics References Shunt trip coil C voltage (V) (+5% to -20%) () 24 48 0 230 400 In-rush consumption (V) 80 00 00 20 20 DC voltage (V) (+5% to -20%) 2 24 48 0 220 In-rush consumption (W) 80 00 00 20 20 () Note: Note: the shunt trip coil must not be supplied for more than 5 s. 230VC shunt trip coil is fitted as standard. C undervoltage trip coil C voltage (V) (+5% to -0%) 24 48 0 230 400 Continuous consumption (V) 3 3 3 3 20 In-rush consumption (V) 3 3 3 3 20 Minimum maintaining voltage (V) 5 25 60 40 200 DC undervoltage trip coil Continuous voltage (V) (+5% to -0%) 2 24 48 0 220 Continuous consumption (W) 3 3 3 3 3 In-rush consumption (W) 3 3 3 3 3 Minimum maintaining voltage (V) 6 5 25 60 40 Delayed undervoltage trip coil Voltage Time (ms) Reference 230 VC 430 3993 3230 () 400 VC 40 3993 3400 () () To be ordered with the switch. Shunt trip coil Voltage Reference Reference 24 VC 3990 024 399 024 () 48 VC 3990 048 399 048 () 0 VC 3990 0 399 0 () 230 VC 3990 220 included 400 VC 3990 380 399 380 () 2 VDC 399 202 () 24 VDC 3990 2024 399 2024 () 48 VDC 3990 2048 399 2048 () 0 VDC 3990 2220 399 2220 () 220 VDC 399 2220 () () To be ordered with the switch. Undervoltage trip coil Replacement coil lternative coil Voltage Reference Reference 24 VC 3990 3024 399 3024 () 48 VC 3990 3048 399 3048 () 0 VC 3990 30 399 30 () 230 VC 3990 3220 399 3220 () 400 VC 3990 3380 399 3380 () 2 VDC 3990 402 399 402 () 24 VDC 3990 4024 399 4024 () 48 VDC 3990 4048 399 4048 () 0 VDC 3990 40 399 40 () 220 VDC 3990 4220 399 4220 () () To be ordered with the switch. Current-reducing resistor for undervoltage trip coil By limiting the current, the resistor reduces the effects on undervoltage trip coils used in continuous processes or those exposed to high ambient temperatures. Voltage Reference 0 VC 3999 32 230 VC 3999 3230 400 VC 3999 3400 0 VDC 3999 40 General Catalogue 207-208 97

ccessories (continued) uxiliary contact re-break and signalling of positions 0 and I: to 2 NO / NC auxiliary contacts. Coil tripping to 2 NO / NC auxiliary contacts. Connection to the control circuit By 6.35 mm fast-on terminal. Characteristics NO / NC auxiliary contact: I2. Electrical characteristics: 30000 operations. acces_048_a cat Characteristics References NO / NC position contact Operating current I e () 250 VC 400 VC 24 VDC 48 VDC Rating () Rated current () C-3 C-3 DC-3 DC-3 250... 800 6 2 8 4 6 NO / NC coil trip signalling Operating current I e () 250 VC 400 VC 24 VDC 48 VDC Rating () Rated current () C-3 C-3 DC-3 DC-3 250... 800 6 2 8 2 2 NO / NC position contact Rating () C position Reference 250... 800 st 3999 005 250... 800 2 nd 3999 0052 NO / NC low level position contact Rating () C position Reference 250... 800 st 3999 0 250... 800 2 nd 3999 02 NO / NC coil trip signalling Rating () C position Reference 250... 800 3999 003 shrouds Top or bottom protection against direct contact with terminals or connection parts. dvantage erforations allow remote thermographic inspection without the need to remove the shrouds. Rating () No. of poles osition Reference 250 630 top or bottom 3998 3040 250 630 top or bottom 3998 4040 800 top or bottom 3998 3063 800 top or bottom 3998 4063 acces_22_a_2_cat screen Top or bottom protection against direct contact with terminals or connection parts. Rating () No. of poles osition Reference 250... 800 Top or bottom 2998 320 250... 800 Top or bottom 2998 420 Inter-phase barrier Safety isolation between the terminals, essential for use at 690 VC or in a polluted or dusty atmosphere. Rating () No. of poles Reference 250 600 2998 0003 250 600 2998 0004 800 3 / included acces_036_a_2_cat 98 General Catalogue 207-208

Key handle interlocking system Locking in position 0 of the front or side operation handle: - using a padlock (not supplied) and standard padlocking function of the handle. adlocking in external front operation interlocks the door. - using a RONIS 04 lock (key BC 338) - to be mounted directly on the padlockable handle, - using RONIS EL lock (not supplied). acces_00_b x_cat Locking using RONIS EL lock 04 (supplied) Rating () Operation Reference 250 800 direct 3999 804 RONIS 04 lock Locking using RONIS EL lock (not supplied) Rating () Operation Reference 250 630 direct 3999 607 800 800 direct 3999 7007 Locking using RONIS EL lock (not supplied) Rating () Operation Reference 250 800 external 499 770 Cage terminals Connection of bare copper cables onto the terminals (without lugs). Connections Rating () lexible cable cross-section (mm 2 ) Rigid cable cross-section (mm²) lexible bar width (mm) Stripped over (mm) 250 6 85 6 85 8 27 400 50 240 50 300 20 34 630 70 300 70 300 24 34 Dimensions acces_053_a_2_cat Rating () C R Ø Z 250 62 3.5 3.5 25 0.5 M6 4 400 7.5 32 38 32 0.5 M20 5 630 76.5 37 38 40 2.5 M20 5 References Rating () No. of poles Reference 250 5400 3025 250 5400 4025 400 5400 3040 400 5400 4040 630 5400 3063 630 5400 4063 ø Z C R acces_092_a x_cat acces_09_a x_cat Other specific accessories Connection accessories. Mounting plates for standard systems. Special construction available for specific environments. General Catalogue 207-208 99

Characteristics according to IEC 60947-3 250 to 800 Thermal current I th at 40 C 250 400 630 800 250 600 800 Rated insulation voltage U i (V) 000 000 000 000 000 000 000 Rated impulse withstand voltage U imp (kv) 8 2 2 2 2 2 2 Rated operational currents I e () Rated voltage Utilisation category /B () /B () /B () /B () /B () /B () /B () 400 VC C-22 / C-22 B 250/250 400/400 630/630 800/800 250/250 600/600 600/800 400 VC C-23 / C-23 B 250/250 400/400 630/630 630/630 250/250 600/600 600/600 500 VC C-22 / C-22 B 250/250 400/400 630/630 800/800 250/250 600/600 600/600 500 VC C-23 / C-23 B 200/250 35/400 500/630 630/630 000/000 250/250 250/250 690 VC (2) C-2 / C-2 B 250/250 400/400 630/630 800/800 250/250 600/600 600/600 690 VC (2) C-22 / C-22 B 250/250 400/400 500/630 630/800 000/000 250/250 250/250 690 VC (2) C-23 / C-23 B 200/250 35/400 400/500 500/500 800/800 000/000 000/000 400 VDC DC-20 / DC-20 B 250/250 400/400 630/630 800/800 250/250 600/600 800/800 400 VDC DC-2 / DC-2 B 250/250 400/400 630/630 800/800 250/250 600/600 600/600 400 VDC DC-22 / DC-22 B 250/250 400/400 (3) 630/630 (3) 800/800 (3) 250/250 (4) 600/600 (4) 600/600 (4) 400 VDC DC-23 / DC-23 B 200/250 35/400 (3) 500/630 (3) 630/800 (3) 250/250 (4) 250/250 (4) 250/250 (4) Operational power in C-23 (kw) t 400 VC without pre-break in C-23 (kw) ()(5) 32/32 220/220 355/355 355/355 70/70 900/900 900/900 t 690 VC without pre-break in C-23 (kw) ()(5) 85/220 295/400 400/475 475/475 750/750 900/900 900/900 Reactive power (kvar) t 400 VC (kvar) (5) 5 85 290 365 575 use protected short-circuit withstand (k rms prospective) rospective short-circuit (k rms) (6) 00 00 00 00 00 20 20 ssociated fuse rating () (6) 250 400 630 800 250 2 x 800 2 x 900 Short-circuit capacity (without protection) Rated short-time withstand current 0.3 s. I CW (k rms) 7 25 50 65 65 80 80 Rated peak withstand current (k peak) (6) 30 45 55 80 00 20 20 Connection Minimum Cu cable cross-section (mm 2 ) 95 85 2 x 50 2 x 85 4 x 240 Minimum Cu busbar cross-section (mm 2 ) 2 x 30 x 5 2 x 40 x 5 2 x 60 x 5 2 x 80 x 5 Maximum Cu cable cross-section (mm 2 ) 240 240 2 x 300 2 x 300 4 x 85 6 x 240 8 x 240 Maximum Cu busbar width (mm) 40 40 50 63 00 00 00 Tightening torque min (Nm) 20 40 40 20 40 40 Mechanical characteristics Durability (number of operating cycles) 8000 8000 5000 5000 5000 3000 3000 Weight of a 3 pole device (kg) 6.5 7 8 4 9 2 Weight of a 4 pole device (kg) 7.5 8 9.5 3 6 2.5 23.5 () Category with index = frequent operation - Category with index B = infrequent operation. (2) With terminal shrouds or phase barrier. (3) oles cannot be juxtaposed. (4) 4-pole device with 2 poles in series per polarity. (5) The power value is given for information only, the current values vary from one manufacturer to another. (6) or a rated operational voltage Ue = 400 VC. 00 General Catalogue 207-208

Dimensions - ront operation 250 to 800 Direct front operation External front operation U M W R Z Y sdmat_06_c x_cat K C B V T J 2 N H V2 C 90 E min. 6 20. shroud 2. 70 reset Overall dimensions shrouds Switch body Switch mounting Connection Rating () 4p. W C E min C 4p. H J J 4p. K M N 4p. R T U V V2 W 4p. Y Z 250 435 495 309 248 275 388 285 345 48 253 33 5 20 80 0 70 7 65 32 35 43 3 46 3 67 238 400 435 495 309 248 275 388 285 345 48 253 33 5 20 80 0 70 7 65 32 35 43 3 3 46 5 69 238 630 435 495 38.5 248 275 388 285 345 48 253 33 5 20 80 0 70 7 65 32 35 43 3 3 46 8 72 257 800 49 570 350 262 296 470 346 426 78 308 388 60 250 250 20 00 9 80 50 60 60 5 36 65 7 72 320 250 to 800 Direct front operation External front operation 6 U M 250 60 Z Y 2 90 C B 250 sdmat_062_c x_cat K 9 V 59 20 J 256.5 E min. 6 20. 70 reset 2. screens Overall dimensions shrouds Switch body Switch mounting Connection Rating () 4p. B E min C 4p. J J 4p. K M M 4p. U V Y Z 250 582 702 355 250 480 437 557 400 520 65 345 465 63 65 7 06 330 600 582 702 370 250 480 437 557 400 520 80 345 465 80 80 5 0 360 800 582 702 370 250 480 437 557 400 520 80 345 465 00 80 5 0 360 General Catalogue 207-208 0

Dimensions for side operation 250 to 800 sdmat_036_d x_cat Direct side operation 372,5 90 90 V V2 H 279.5 89.5 Z Y U T M 2 W External side operation 250 to 800 Direct side operation External side operation 60 Z 89.5 6 M 250 90 U Ø9 2 90 372,5 C K 250 == R N C K D 6 20. 70 reset 2. shrouds Overall dimensions shrouds Switch body Switch mounting Connection Rating () 4p. D D 4p. C 4p. H K M N 4p. R T U V V2 W 4p. Y Z 250 365 425 357 47 388 285 345 48 5 20 80 0 70 7 65 32 35 43 3 46 3 67 238 400 365 425 357 47 388 285 345 48 5 20 80 0 70 7 65 32 35 43 3 3 46 5 69 238 630 365 425 357 47 388 285 345 48 29 20 80 0 70 7 65 45 49 49 3 3 46 8 72 257 800 42 50 43 493 470 346 426 78 60 250 250 20 00 9 80 50 60 60 5 36 65 7 72 320 sdmat_037_e x_cat 70 279,5. 70 reset 2. screens V Y 43 20 20 20 62 D 6 20 Overall dimensions shrouds Switch body Switch mounting Connection Rating () 4p. D D 4p. C 4p. M M 4p. U V Y Z 250 522 64 504 624 480 437 557 345 465 63 65 7 06 330 600 522 64 504 624 479 437 557 345 465 80 80 5 0 360 800 522 64 504 624 479 437 557 345 465 00 80 5 0 360 02 General Catalogue 207-208

Dimensions for external handles 800 to 800 Handle type S3 type Ø78 ront operation Direction of operation Door drilling RESET 70 20 20 0 90 4 Ø 7 Side operation Direction of operation Door drilling I 90 Ø 37 4 Ø 7 20 I 44 0 20 20 sdmat_075_a fr_cat 6 Ø 37 70 RESET 44 Connection terminal 800 250 600 800 ø9x ø5 6 x ø 3 ø 3 sdmat_043_a x_cat 30 33 50 30 33 0 sdmat_044_a x_cat 9 25 9 63 7 25 sdmat_045_a x_cat 20 40 20 80 20 40 sdmat_057_a x_cat 25 50 25 00 20 40 General Catalogue 207-208 03