AquaTrans AT600. Panametrics Clamp-on Ultrasonic Liquid Flow Meter. Imagination at work. Version 3 (12/1/14)

Similar documents
SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control. Benefits.

GE Sensing & Inspection Technologies. Model UTXDR. Panametrics Ultrasonic Flow Transducer. Installation Guide

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Sensing & Inspection Technologies. Benefits.

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

Time Delta S Fixed Transit-Time Flow Meter System

UTM10 Series Ultrasonic Transit-time Flowmeters

ThermoPro TM Series TP10

Range of Ultrasonic Flowmeters.

GE Panametrics Ultrasonic Flow Meter

F-2600 SERIES INLINE VORTEX FLOW METER

Principle of Operation

DYNAMETERS SERIES DMTF ULTRASONIC FLOW METER

flow measurement solutions RIM10 series rotor insertion flowmeters

STUF-280W. Features: Ultrasonic Water Meter, DN15~DN40. Ultrasonic Water Meter DN50~DN600

tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

An IDEX Water & Wastewater Business. pulsafeeder.com. Hydraulic Diaphragm Metering Pump

F-2500 SERIES VORTEX METER

Portable Transit Time Flow Meter for Accurate Flow Measurement from Outside a Pipe

Model DFX Doppler ultrasonic flow meter

Adding value every day

ISTEC MAGNETIC METERS

Paddle-wheel flow controller for On/Off control

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Inline Ultrasonic Flowmeter

GE Measurement & Control Solutions. CModel C-RS. Ultrasonic Flow Transducer. Installation Guide

F-2600 SERIES INLINE VORTEX FLOW METER

ULTRAFLO 2000 ULTRASONIC LIQUID FLOW AND HEAT/ENERGY METERS FOR PERMANENT INSTALLATION HIGH TEMPERATURE SENSORS AS STANDARD

VLM20 In-line Vortex Flowmeter

tprime TM Series 280T

F111.X Flow Sensor for Hot Tap Installation INSTRUCTION MANUAL. 1. Introduction Safety Instructions Unpacking Description.

Full Profile Insertion

F-1500 SERIES INSERTION TURBINE FLOW METER

INSERTION flowmeter with paddle wheel, ELEMENT design

ThermoPro TM Series TP10

Hand held ultrasonic flow meter

REVOLUTIONIZE YOUR GAS DENSITY AND PURITY MEASUREMENT TECHNOLOGY

An IDEX Water & Wastewater Business. pulsafeeder.com. Non-Metallic External Gear Pump

ULTRASONIC HEAT METER

F-2700 SERIES INSERTION VORTEX FLOW METER

TABLE OF CONTENTS Service Information 2 Quick Start Instructions 4-5 Introduction 6 Specifications 6 Controls and Terminology

Paddle-wheel flow controller for On/Off control

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

Bulletin VX05 VANEAXIAL FANS

MAIN FUNCTION FEATURES. . D = v t /2

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Low Profile Insertion Vortex

Eclipse. The Power of Design Innovation. Series

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater

Model FVP General Specification. Flanged Vortex Plate. Product Features

Lower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS).

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date

WATER & IRRIGATION METERS QUALITY FLOW METERS FOR THE AGRICULTURE AND AQUIFER MANAGEMENT. Quality Engineered Systems

TRANSIT TIME FLOW METERS

SENSOR MUT2300. Electromagnetic flowmeter. The electromagnetic flowmeter designed for the toughest applications DS401-1-ENG

Online data sheet FLOWSIC100 VOLUME FLOW MEASURING DEVICES

Hot Tap Insertion Vortex

Transmitting Transducer. Gas/Air Velocity Range:

RT Series Rotary Stage Design

ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products Rev PK KMS501W & KMS502F- TW. Electromagnetic TRADEWASTE Flowmeters FEATURES:

Linear Actuator with Ball Screw Series OSP-E..S. Contents Description Overview Technical Data Dimensions 79

True Fail-Safe Technology and Precision Control for Reliable Shutdown

Flow Measurement SITRANS F S Clamp-on

BATCHFLUX 5500 C Technical Datasheet

Linear Actuator with Ball Screw Series OSP-E..S. Contents Description Overview Technical Data Dimensions 89

M-2800 Series. Inline Ultrasonic Flow Meter. Description. Measurement Principle. Key Features. Applications

F-2700 SERIES INSERTION VORTEX FLOW METER

STEEMCO-MAS Flowmeter for Steam

Portable Ultrasonic Flow Measuring System prosonic flow 92

Holiday Detector Data Sheet / Instructions

mass flowmeter for compressed air

INSTRUCTION MANUAL. 1. Introduction 2. Safety Instructions.. 2 Unpacking Description. 2. Main Features... 3 Technical Data...

Fluid Power Fluid Power

NCM-603 Hand Held Clamp-on Ultrasonic Transit Time Flowmeter

Flexibility and precision in high-performance production. SKF solutions for material joining technologies

Paddle-wheel flow controller with optical principle for On/Off control

PULSAPRO HYDRAULIC DIAPHRAGM METERING PUMP API-675 ENGINEERED PRODUCTS. Flow: up to 270 gph (1,022 lph) Pressure: up to 5,100 psi (350 bar)

STEEMCO Flowmeter for Steam

FLOWX3 F3.60M.S Insertion Magmeter

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

EASZ-10P Operating Instructions

Micro Motion T-Series Straight-Tube Mass Flow and Density Meters. Product Data Sheet PS July 2001

Armstrong In-Line and Insertion Vortex Flow Meters

VORTEX IN-LINE FLOW METERS

INSERTION flow sensor for continuous flow measurement

SENSOR MUT2300. Electromagnetic flowmeter. The electromagnetic flowmeter designed for the toughest applications DS401-1-USA

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

Flow Measurement SITRANS F US Clamp-on

Transducers, Cables, Couplants and Test Blocks for Ultrasonic Precision Thickness Gages

PULSAPRO HYDRAULIC DIAPHRAGM METERING PUMP API-675 ENGINEERED PRODUCTS. Flow: up to 270 gph (1,022 lph) Pressure: up to 5,100 psi (350 bar)

Permanent Multipath Clamp-On Transit Time Flow Meter

Marsh McBirney Flo-Dar

Linear Actuator with Toothed Belt Series OSP-E..B

INDEX. Introduction. Introduction. Sensor Mounting. Keypad System. Battery. Menu System. Error/Warning Messages. Troubleshooting guide

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

Ultrasonic Flow Meter Series Smart-IN US. Features. Description

mass flowmeter for compressed air

Transcription:

AquaTrans AT600 Panametrics Clamp-on Ultrasonic Liquid Flow Meter Imagination at work. Version 3 (12/1/14)

I need a meter that is reliable and user friendly. 2

Introducing the AquaTrans AT600. Simplicity meets reliability. The new clamp-on ultrasonic meter designed to measure liquid flow in industrial environments

A totally new clamp-on system THE AT600 INCLUDES AT600 electronics 1 1 Transducer cables 2 2 3 Transducers/fixture AT6 XDR with fixture (2 MHz) C-RS XDR with CF-ES fixture (0.5 MHz) 3 AT600 Installation 4

Clamp-on transit time. Up c P L Velocity Variables used in transit time Dn V = Fluid Velocity c T up T d n P = Fluid soundspeed = Transit time up = Transit time down = Acoustic path length V = P 2L 2 t t up dn - t t dn up L = Axial projected path length 5 = Path Angle

Advantages of an ultrasonic meter No drifting, no periodic calibration required No pressure drop No restriction in the pipe No filters or strainers No loss of process control, optimization of assets and efficiency, no downtime or expense from calibration No wasted energy from running a pump or purchase of a larger size pump Contamination will not affect meter s measurement (drifting) or any damage to meter No maintenance cost Bi-directional measurement No moving parts Flow measurement independent of temperature, pressure, viscosity and conductivity No additional meters required No loss of process control, optimization of assets and efficiency, no downtime or expense from calibration No impact to accuracy, which affects process control

Advantages of a clamp-on meter Install on new or existing pipes Save time and money not cutting into pipe, install in difficult locations, install anytime Install on outside of pipe No welding, no extra parts Save time and money not cutting into pipe, no process shutdown, no process contamination Save time and money No leakage No contamination No required maintenance Low cost of ownership

Improves on its predecessor A continued legacy of reliability MORE RELIABLE Accuracy for a clamp-on meter BETTER ACCURACY Great value for ultrasonic flow measurement BEST VALUE Simple installation, intuitive set-up CONFIDENCE IN MEASUREMENT 8

Designed to be better Applying GE s industrial design Epoxy-coated aluminum (NEMA 4X/IP67) Green or red light health indication Six-button keypad Multiple languages Two-inch pipe or wall mount Friction hinge design Latch with lock opening for local security Five watts maximum power consumption Temperature range: 4 to 131 F (-20 to 55 C) 4-20 ma with two discrete outputs Modbus/RS485 and HART options Vitality software-capable 9

Small yet powerful New AT6 transducer Small and compact, about 33 mm (1.3 in) 2 MHz operating frequency IP68 rating with cable standard Solid couplant, standard Temperature range of -40 to 302 F (-40 to 150 C) Current transducer option C-RS with AT868 fixture 0.5 & 1 MHz operating frequency Familiar set-up 10

Uncomplicated, quick installation Easy-to-use fixture Quick-tighten stainless strapping Pre-installed transducers Easy-to-read spacing markings Simple adjustment and alignment Anodized aluminum Lightweight 11

A simple four-step process Install in minutes STEP 1 STEP 2 Mount and wire Program meter 3 MINUTES* 5 MINUTES* STEP 3 STEP 4 Install transducers and fixture 5 MINUTES* Validate measurements 2 MINUTES* * Average estimated time 12

Specifications Item Fluids Measurement Channels/paths Pipe sizes Pipe materials Details Liquids Transit time One 2 to 24 in (50 to 600 mm) standard (Other sizes available upon request.) All metals and most plastics Accuracy Calibration +/- 1% of reading +/- 0.5% in field calibration Final installation assumes a fully developed flow profile (typically 10 diameters upstream and 5 diameters downstream of straight pipe run) and single phase fluids. Applications with piping arrangements that induce swirl (e.g., two out-ofplane elbows) may require additional straight run or flow conditioning. Standard with each meter Repeatability +/- 0.2% Range Certification -40 to 40 ft/s (-12.2 to 12.2 m/s) CE, UL, CSA Mcert (in process) 13

Backed by experience Panametrics ultrasonics expertise Revolutionizing the industry for over 50 years Legacy of innovation Committed to setting the industry standard Fortified by GE s global reach and reliability 50 YEAR REAC S H #1 IN ULTRASONICS Global leader in high-technology ultrasonic process control instrumentation 14

AT600. Simplicity meets reliability. Ultrasonic clamp-on advantages State-of-the-art design Easy to use Quick installation Accurate and repeatable Reliable and maintenance-free in the field Backed by 50 years of ultrasonic experience 15