330mm (13") MAXIMUM WALL THICKNESS IN AREA OF UNIT. 330mm (13") MAXIMUM WALL THICKNESS IN AREA OF UNIT TYPICAL ACCESS TO LEVELING 15

Similar documents
330mm (13") MAXIMUM WALL THICKNESS IN AREA OF UNIT. 330mm (13") MAXIMUM WALL THICKNESS IN AREA OF UNIT (2) EACH SIDE OF SAFE CEN I SAFE ONLY

203mm (8") MAXIMUM WALL THICKNESS IN AREA OF UNIT NOTE: 203mm (8") MAXIMUM WALL THICKNESS IN AREA OF UNIT (2) EACH SIDE OF SAFE CEN I SAFE ONLY

DIEBOLD 3700 LOBBY CASH RECYCLER- FRONT LOAD 15" DISPLAY OR 19" DISPLAY CEN I, CEN III GAS, CEN IV GAS or CEN IV GAS EX SAFES

OPTIONAL 178mm (7") SPACER AVAILABLE FOR WALL THICKNESSES UP TO 152mm (6") 330mm (13") MAXIMUM WALL THICKNESS IN AREA OF UNIT

DIEBOLD 5550 CASH DISPENSER THROUGH 330mm (13") MAXIMUM WALL PLAN VIEW FRONT ELEVATION SIDE ELEVATION CONSUMER ACCESS DIMENSIONS

DIEBOLD 3750 CASH RECYCLER TERMINAL. 13mm ( 2") UL SAFE - 15" OR 19" DISPLAY THROUGH THE WALL 330mm (13") PLAN VIEW FRONT ELEVATION SECTION

CS 7780 FULL FUNCTION DRIVE-UP TERMINAL

CS 7750 FULL FUNCTION TERMINAL 15" OR 19" DISPLAY - THROUGH THE WALL 330mm (13")

SEE PAGES 3 AND 4 OF 7 FOR 3700 CASH RECYCLER THROUGH THE WALL WITH VESTIBULE TRIM KIT REFERENCE FRONT EDGE OF BEZEL FOR DEPTH DIMENSIONS

STANDARD AND FULL HEIGHT - REAR LOAD - WITH 40mm (1 16") CEN I, CEN III GAS or CEN IV GAS SAFES

* * * DIEBOLD 3700 LOBBY CASH RECYCLER- FRONT LOAD 15" DISPLAY OR 19" DISPLAY CONSUMER ACCESS DIMENSIONS PLAN VIEW 19" DISPLAY FRONT ELEVATION

9900 IN LOBBY TELLER - (ILT) PORTRAIT AND LANDSCAPE DISPLAY PLAN FRONT VIEW SIDE VIEW PAGE 1 OF 6 CALL

COIN DISPENSER SIDE CAR FOR INSTALLATION NEXT TO DIEBOLD IN LOBBY TELLER (ILT) PLAN FRONT VIEW SIDE VIEW PAGE 1 OF 7 CALL

DIEBOLD IN LOBBY TELLER (ILT) PORTRAIT OR LANDSCAPE INSTALLED WITH A COIN RECYCLER SIDE CAR PLAN FRONT VIEW SIDE VIEW PAGE 1 OF 7

3700 LOBBY CASH RECYCLER. REAR LOAD 13mm ( 2") UL SAFE - 15" DISPLAY OR 19" DISPLAY WITH DETAILS FOR OPTIONAL VESTIBULE INSTALLATION

* * * 3700 LOBBY CASH RECYCLER. REAR LOAD 13mm ( 2") UL SAFE - 15" DISPLAY OR 19" DISPLAY WITH DETAILS FOR OPTIONAL VESTIBULE INSTALLATION

CS 5700 LOBBY CASH DISPENSER REAR LOAD - 15" DISPLAY OR 19" DISPLAY TYPICAL ACCESS TO LEVELING LEGS - RANGE (2) EACH SIDE OF SAFE CEN I SAFE ONLY * *

CS 7700 FULL FUNCTION LOBBY TERMINAL REAR LOAD - 15" OR 19" DISPLAY

POWER BUTTON: 25mm (1") CONDUIT X 3048mm (10'-0") LONG TO HOUSE POWER AND CONTROL CABLES (SUPPLIED BY DIEBOLD)

CALL HEIGHT CARD READER TOP OF MONITOR FRONT SIDE CONCRETE SURFACE TO BE FLAT AND LEVEL IN AREA OF UNIT

152mm (6") DIA. POINT TO POINT SYSTEM PVC OR STEEL TUBE SYSTEM TYPE I AND TYPE II OVERHEAD UNITS TYPE I OVERHEAD UNIT TYPE II OVERHEAD UNIT NOTES:

OPTEVA 378 ENHANCED CASH RECYCLER TERMINAL FRONT LOAD LOBBY UNIT PLAN VIEW FRONT VIEW SIDE VIEW

330mm (13") MAXIMUM WALL THICKNESS IN AREA OF UNIT. 330mm (13") MAXIMUM WALL THICKNESS IN AREA OF UNIT (30 HEIGHT NOTE SEE W ALL OPENING

203mm (8") MAXIMUM WALL THICKNESS IN AREA OF UNIT. 203mm (8") MAXIMUM WALL THICKNESS IN AREA OF UNIT (30 HEIGHT NOTE SEE W ALL OPENING

CCD-493 KIT SERIES INSTRUCTION SHEET

CC-410 KIT SERIES INSTRUCTION SHEET

CCS-810 KIT SERIES INSTRUCTION SHEET

OPTEVA 923 IN LOBBY TELLER (ILT) PLAN mm (60") WIDE PLAN - STAND ALONE FRONT VIEW SIDE VIEW PAGE 1 OF 5 CALL NOTE:

UPS Pure Sinewave UPS

ABB industrial drives. Mechanical installation instructions ACS880 multidrive cabinets

DIESEL EGT GAUGE INSTALLATION INSTRUCTIONS P14D AA

DPST-NO None 2 channels Auto-reset Inverse 24 VAC/VDC G9SB-2002-A 4 1 channel or 2

RPEA3-06. Functional Description HA /2011. Directional Control Valves Solenoid Operated with 8W Coil. Replaces HA /2007

[1200mm] 5" [125 mm] 2 3/4" [70mm] [2600mm] [450mm]

Specifiable Features. Compatible with all UL 1686 listed plugs and receptacles. Type P Cable. Lockout Compliant. PowerMate Features and Benefits

Lincoln Under-cabinet Light Installation Instructions

Schematic diagram for the 8200 vector, 230 V Schematic diagram for the 8200 vector, 400/500V 1)

4%$ %%X 0RODUCT!PPLICATION 4HE "OTH 4%$ FOR 4%$ 80 DUSTTIGHT 2ATINGS

Pneumatic Actuators 1000, 1400, 2800, and 2 x 2800 cm² Type 3271 and Type 3277 for integral positioner attachment Hand-operated Actuator Type 3273

Precision Pressure Transmitter with Switching Contacts and Display. Interface Setup program. Display 4 characters. Switching output 1.

THIS COPY IS PROVIDED ON A RESTRICTED BASIS AND IS NOT TO BE USED IN ANY WAY DETRIMENTAL TO THE INTERESTS OF PANDUIT CORP.

EVA II - ELECTRONIC VAULT ATTENDANT SYSTEM PERSPECTIVE TOP VIEW FRONT VIEW EVA II - TOUCH SCREEN KIOSK EVA II - WIRING DIAGRAM PAGE 1 OF 6

Two-Position Electric Duplex Room Thermostats


Safety Relay Unit. Ordering Information. Ultra Slim Safety Relay

Special Valves. Connection size G1/8 to G2. Contents Version Actuation Port size Page Characteristics. Instructions Overview. Electrical G1/8 G1/4

Roller and ball bars for easy and safe die change

TECHNICAL INSIGHT INTERNAL CLEARANCE - TYPES AND NORMS

631 ALLOWANES AND TOLERANCES

SINEAX C 402 Alarm unit

VB-7000 Series. Selection Guide. Applications. Applicable Literature. Selection Guide Contents

ELECTRICAL SYSTEM 4 D INSTRUMENTATION

Data Sheet T /4/5/6 EN

Transmission and Driveline. Section 2A - Transmission and Driveline

EFFEKTA. Solar inverter HX-Series NEU / NEW

Cable Trolleys for C-Rails Program

Proportional directional valves

Hot Air Thermostats. WTHc series. Special features. Brief description. Switching function. Approval/approval marks (see "Technical data")

POWER COMBICON Plugs and Headers PC 6/ for Currents up to 41 A, mm Pitch

JUMO MIDAS S05 OEM pressure transmitter - universal

00083FAB-DC DRAWN BY DATE CHK SCALE SIZE

KING COBRA/KING COBRA-2 NARROW STILE SERIES KC9357/KC9357-2

AIRCRAFT ENGINES SERVICE INSTRUCTION ENGINE START AT LOW TEMPERATURES AT ROTAX SI R1

4/2- and 4/3-way shut-off valve

Blocked for new applications / Für Neuanwendung gesperrt

Spark Plug Fouling 3.0 Liter OptiMax

NET-ACCESS S TYPE VED READY CABINET 600mm WIDE X 1200mm DEEP FAMILY 12V343ST-DC VED TOP CAP FRONT PERFORATED SINGLE HINGE DOOR SPLIT SIDE PANEL

TOP CAP KNOCK-OUTS FOR

(mω) 1. Temperature ( C) Voltage (V) ULRG1 /

@ ECV Technical Data High Lift Pallet Truck. ECV 10 C ECV 10i C ECV 10

Electrically controlled directional control poppet valve type UREZ6

PERSEUS ULTRA LOW PRESSURE

POWER TRIM. Table of Contents. Section 5D - Auto Trim II

GENERAL NOTE: GRADE 4-#8 AND 1-#8 EGC IN 1" CONDUIT TO POLE P2. 4-#8 AND 1-#8 EGC IN 1" CONDUIT TO POLE P1.

Hand-operated Actuator Type 3273

Brazed heat exchanger XB

WATERTIGHT AIRTIGHT SPECIAL ACCESS DOORS & HATCHES, PART 1 GENERAL

EVA II - WINDOWS 10 ELECTRONIC VAULT ATTENDANT SYSTEM SIDE VIEW

MPC COBRA SERIES. Manually Programmable Cylindrical Lock D

Installation and Operational Instructions for ROBA -slip hubs Sizes 0 12 (B.1.0.GB)

Spring Return DuraDrive Two-Position Actuator

ELECTRICAL. Table of Contents. Section 2A - Ignition

3-Way Ball Valve Assemblies Using TAC DuraDrive Actuators

A battery of 19 Rectangular Portal Culverts under a major road. Rectangular Portal Culvert used as an inclined mine shaft.

13V399AN-DC DRAWN BY DATE CHK SCALE SIZE

DSE /116 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 10 SUBPLATE MOUNTING ISO p max 320 bar Q max 90 l/min

4/3, 4/2 and 3/2 explosion-proof solenoid directional valve

Print This Page. Return To Index

SHEET 1 OF 6

Convenience electronics

POWER TRIM. Table of Contents. Section 5D - Auto Trim II

Electrically operated directional spool valve with a soft-shift function type WE10P NS 10. up to 35 MPa up to 120 DATA SHEET - OPERATION MANUAL

Application Examples of Air-piloted Valves

ELECTRA-flo G5 TRANSMITTER (Version 2.4) THERMAL AIRFLOW MEASURING SYSTEM

Section 6. Transformers. Table of Contents. General Purpose, Dry Type, 600 Volts and Below. Industrial Control. Instrument, 600 Volt Class

NOTICE. Notice to Users of This Manual ! DANGER ! WARNING ! CAUTION

NT Series SSS MARK-II

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

INSTALLATION GUIDE INSTALLATION GUIDE

JUMO MIDAS C18 SW. OEM seawater pressure transmitter. Applications. Brief description. Customer benefits. Special features. Approvals/approval marks

Transcription:

L CLL -800--600 R DIEBOLD 0 CSH DISPENSER THROUGH 0mm (") MXIMUM WLL 0mm ( 6" ) CEN I, CEN III GS, or CEN IV GS SFES CONSULT WITH DIEBOLD INSTLLTION/SERVICE BRNCH FOR DDITIONL DETILS ND INFORMTION. PLESE SEE PLNNING ND SITE PREPRTION GUIDE TP-86-00. 6 6") (8 6") SFE 88 (") SFE ( ") 0mm (") MXIMUM WLL THICKNESS IN RE OF UNIT B C D E CONSUMER CCESS DIMENSIONS TOP OF DISPLY TOP FUNCTION KEY CONSUMER KEYPD RECEIPT PRINTER ctivdispense HEIGHT 60mm ( ") mm ( 6") 00mm (0 ") 8mm ( ") 0mm ( ") DEPTH mm ( 8") 8mm ( 6") 8mm (6 6") mm ( 8") 6mm ( ") F HEDPHONE JCK 08mm ( 8") 8mm ( 8") G CRD REDER mm ( 6") mm ( 8") THIRD NGLE "LL DIMENSIONS ND DESIGN CRITERI PGE OF SUBJECT TO CHNGE W ITHOUT NOTICE" 66 ") ( 6 ") ( B C D E 6") ( ( ") 6 (0 6 ") PLN VIEW 6 (0 6") F G SEE WLL OPENING DETIL FOR RECOMMENDED CLERNCE REQUIRED ROUND FSCI. 0mm (") MXIMUM WLL THICKNESS IN RE OF UNIT NOTE - WLL OPENING HEIGHT 66 80 68 6") ( 6") ( ( 6") HEIGHT - FROM BOTTOM OF SFE DEPTH - FROM FRONT EDGE OF BEZEL HOLD THIS DIMENSION TO MEET REQUIRED CCESS REQUIREMENTS. DIMENSION GRETER THN 68mm ( 6") MY EXCEED REQUIRED CUSTOMER RECH ND NOT MEET CCESSIBILTY REQUIREMENT GUIDELINES. ") ( 6 ") ( SEE NOTE # 80 68 6") ( 8") 6 ") ( 6 ") ( IR VENTS ( ") 0 SFE 80 6 ") ( ") ( ") ( 6 ") ( ") FILE NO. -68 REV. FRONT ELEVTION NOTE - WLL OPENING HEIGHT INSIDE FLOOR LEVEL MUST BE THE SME S OUTSIDE SIDEWLK LEVEL FOR REQUIRED CCESS. IF INSIDE FLOOR IS HIGHER OR LOWER THN OUTSIDE, DIMENSION FOR LOCTING WLL OPENINGWILL HVE TO BE DJUSTED CCORDINGLY ND REQUIRED OPERTING HEIGHTS MY NOT BE MET FOR REQUIRED CCESSIBILITY STNDRDS. TYPICL CCESS TO LEVELING LEGS RNGE 0-00mm ( 6") () ECH SIDE OF SFE CEN I SFE ONLY TO COMPLY WITH CEN I LEVELING LEGS RE NOT TO BE EXTENDED BELOW SFE BOTTOM ( 8") ( ") 8 ") 88 0 ( 8") 0 88 SFE (") ( ") SIDE ELEVTION CEN I SFE SHOWN - CEN III and CEN IV SFES WILL NOT BE PROVIDED WITH LEVELING 6 ( 6")

THIRD NGLE "LL DIMENSIONS ND DESIGN CRITERI SUBJECT TO CHNGE W ITHOUT NOTICE" PGE OF CONDUIT ND JUNCTION BOX REQUIREMENTS SIGNL CBLE RUN CONSTRINTS THE FOLLOWING CHRT ITEMIZES THE PHYSICL SPCING REQUIREMENTS OF THE SIGNL CBLE RUN WITH RESPECT TO OTHER POWER ND ELECTRICL EQUIPMENT CBLE RUN. TYPE OF ELECTRICL RUN FLUORESCENT, NEON OR INCNDESCENT LIGHTING FIXTURES UNSHIELDED POWER LINE OR ELECTRICL EQUIPMENT UNSHIELDED POWER LINES OR ELECTRICL EQUIPMENT WITH SIGNL CBLES ENCLOSED IN GROUNDED CONDUIT POWER LINES IN GROUNDED CONDUIT WITH SIGNL CBLES IN GROUNDED CONDUIT OWNER'S E.C. TO RUN mm ( ") LIQUID TIGHT FLEX METL CONDUIT OR mm ( ") RIGID CONDUIT FROM JUNCTION BOX TO CBLE CONNECTION PLTE. mm ( ") METL CONDUIT ND UNSWITCHED ELECTRICL SUPPLY TO 0mm (") SQ. X mm ( 8") DEEP JUNCTION BOX WITH RECEPTCLE WITHIN 0mm (8") OF SIDE CONNECTING PLTE. BOTTOM CONNECTION MUST BE COMPENSTED CCORDINGLY (LL BY OWNER'S E.C.) (SEE POWER REQUIREMENTS). OWNER'S E.C. TO SUPPLY COMPTIBLE RECEPTCLE FOR COUNTRY SPECIFIC PLUG-IN CONNECTOR SUPPLIED WITH UNIT. POWER CORD LENGTH 0mm (8") FROM SIDE OF UNIT. SIGNL CBLE INSTLLTION CONSTRINTS: RELTIVE CRE IS REQUIRED WHEN INSTLLING SIGNL CBLES IN CONDUITS, UNLIKE POWER ND LIGHTING CBLE, SIGNL CBLES HVE CONDUCTORS ND LIGHT INSULTION ND WILL NOT WITHSTND S MUCH STRIN IN INSTLLTION. 6") mm (") METL CONDUIT FROM LRM CONTROL CBINET JUNCTION BOX TO 0mm (") SQ. X mm ( 8") DEEP JUNCTION BOX. (LL BY OWNER'S E.C.) DN ONLY-FLT COVER WITH TMPER SWITCH IS PROVIDED BY THE DN SERVICE ORGNIZTION. WHEN "SECUROMTIC" FTER HOUR DEPOSITORY IS TO BE CONNECTED TO CSH DISPENSER, OWNER'S E.C. TO RUN mm ( ") METL CONDUIT FROM 0mm (") SQ. X mm ( 8") DP. JUNCTION BOX TO FTER HOUR DEPOSITORY. JUNCTION BOXES MUST BE LOCTED WITHIN 0mm (8") OF CONNECTING PLTE. (LENGTH OF ELECTRICL POWER CBLE PROVIDED WITH UNIT). LOCTE IN N ESILY CCESSIBLE RE. BOXES CN BE FLUSH MOUNTED WITH CONCELED CONDUIT FOR NEW CONSTRUCTION OR BOXES CN BE SURFCE MOUNTED WITH EXPOSED CONDUIT FOR EXISTING CONSTRUCTION. BUILDING IR PRESSURE BUILDING IR PRESSURE DIFFERENCES T DISPENSER INSTLLTION LOCTION FFECT THE INFILTRTION OF OUTSIDE IR ND CCOMPNY DIRT. THE DISPENSER WILL OPERTE THROUGH ITS FULL RNGE OF FSCI TEMPERTURES -º C TO º C (-º F TO º F) WITH ZERO (STTIC) OR POSITIVE IR PRESSURE DIFFERENTIL (MESURED FROM THE INSIDE TO THE OUTSIDE OF THE BUILDING T THE TM INSTLLTION LOCTION). IF STTIC OR POSITIVE IR PRESSURE CNNOT BE MINTINED, THE FSCI LOWER LIMIT TEMPERTURE IS -0º C (-º F). THE MXIMUM NEGTIVE IR PRESSURE LLOWED IS 0.0" H O. 0 80 6 ") ( ") ( 6 ") ( 0 ( ") ") ( ") ( ( ") (0 8 ") SEPRTION FROM OTHER CBLES BELOW KV - KV BOVE KV mm (") mm (") mm (") mm (") 0mm ('-0") 60mm ('-0") 6mm ( ") mm (6") 0mm ('-0") 0mm ( 6") 6mm (") mm (6") 6 6 ( 6") IR VENTS POWER REQUIREMENTS: DISPENSER REQUIRES SINGLE-PHSE, THREE-WIRE UNSWITCHED POWER RECEPTCLE. WIRING TO THE RECEPTCLE MUST INCLUDE THIRD-WIRE ERTH GROUND (CONDUIT GROUND IS NOT CCEPTBLE). DISPENSER WILL PROVIDE POWER CORD WITH COUNTRY SPECIFIC POWER PLUG. THE POWER SUPPLIED MUST BE S SPECIFIED BELOW. CHOOSE ND SUPPLY THE PROPER POWER FOR THE SITE: 6") 0 80 00- VC (+6%, -0%) T 0 (±%) Hz, SINGLE-PHSE 00- VC (+6%, -0%) T 60 (±%) Hz, SINGLE-PHSE 00-0 VC (±0%) T 0 (±%) Hz, SINGLE-PHSE 00-0 VC (±0%) T 60 (±%) Hz, SINGLE-PHSE POWER TO DISPENSER IS TO BE DEDICTED SERVICE ND MUST BE PROTECTED BY SFETY QUICK-DISCONNECT DEVICE TO BREK LINE VOLTGE (SUCH S CIRCUIT BREKER T THE ELECTRICL SERVICE PNEL. THE QUICK-DISCONNECT DEVICE (OR CIRCUIT BREKER) MUST TURN OFF THE LINE VOLTGE T THE FOLLOWING MPERGE. 00- VC (+6%, -0%) SERVICE, DISCONNECT T MPERES 00-0 VC (±0%) SERVICE, DISCONNECT T 0 MPERES THE MODULE BULK POWER SUPPLY ND PROCESSOR POWER SUPPLY WILL PROVIDE POWER CONDITIONING TO PREVENT THE TERMINL FROM MLFUNCTIONING DUE TO SHORT-TERM C POWER FLUCTUTIONS S OUTLINED IN EN6000--. POWER USGE MCHINE STTUS IDLE (NO TRNSCTION) TRNSCTION (DISPENSE IN PROGRESS) CONFIGURTION HET OUTPUT CONFIGURTION CSSETTE DISPENSER. OPERTING ENVIRONMENT WEIGHT OF UNIT 6 ") ( ") ( 6 ") ( TEMPERTURE (INSIDE T OUTSIDE WLLS OF UPPER CBINET ND SFE) 0 C TO 0 C ( F TO F) (REQUIRES SOLID STTE DRIVE (SSD) IN ctivcore PROCESSOR. IF HRD DISK DRIVE (HDD) DRIVE IS USED, THE MX OPERTING TEMPERTURE IS REDUCED TO 0 C (0 F) - C TO C (-0 F TO F) ( ") 60 WTTS WTTS 0 BTU/HR IDLE BTU/HR DISPENSING 6 ") ( 8 ") POWER CORD 0mm (8") LONG FROM SIDE OF UNIT WITH BTTERY CHRGING 8 WTTS 0 WTTS LL-IN-ONE PROCESSOR, MOTORIZED CRD REDER, RECEIPT PRINTER, ND THE POWER USE DEPENDS ON THE NUMBER ND TYPE OF DEVICES PRESENT IN THE CSH DISPENSER, ND THE TYPE OF TRNSCTION THE CSH DISPENSER IS PERFORMING. VLUES BOVE RE BSED ON MESURED VERGES FOR THE CONFIGURTION LISTED. SFE WITH BTTERY LOCTION OUTSIDE T FSCI CHRGING 0 BTU/HR IDLE 0 BTU/HR DISPENSING RELTIVE HUMIDITY ( NON-CONDENSING ) 0 TO 80% T º C (0º F), 0 TO % T 0º C (0º F) CEN I --------------------------------- 6kg (6 LBS.) PPROXIMTE. CEN III ------------------------------- 66kg (80 LBS.) PPROXIMTE CEN IV -------------------------------- 66kg (0 LBS.) PPROXIMTE CTUL WEIGHT OF THE TERMINLWILL DEPEND ON THE CONFIGURTION OF THE TERMINL COMPONENTS ND OPTIONS 6 6 ") ( ") ( ( 6 ") ( 6 ") 8 ( 8 ") IR VENTS 80 68 6") ( 6") ( SEE W LL OPENING HEIGHT NOTE PGE OF FILE NO. -68 REV. SFE ( ") BCK ELEVTION TYPICL CCESS TO LEVELING LEGS RNGE 0-00mm ( 6") () ECH SIDE OF SFE CEN I SFE ONLY TO COMPLY WITH CEN I LEVELING LEGS RE NOT TO BE EXTENDED BELOW SFE BOTTOM ( 6 ") ( ") 0 ( 6 ") 88 SFE (") 88 ( 8 ") ( ") 8 0 ( ") ( 8 ") SIDE ELEVTION CEN I SFE SHOWN - CEN III and CEN IV SFES WILL NOT BE PROVIDED WITH LEVELING

R DIEBOLD 0 CSH DISPENSER THROUGH 0mm (") MXIMUM WLL 0mm ( 6" ) CEN I, CEN III GS, or CEN IV GS SFES CLL -800--600 WLL OPENING DETILS THIRD NGLE "LL DIMENSIONS ND DESIGN CRITERI SUBJECT TO CHNGE W ITHOUT NOTICE" PGE OF 0 ") ( 0 (") 80 6") ( ( ") PLN VIEW 68 ( 6") ( 8 ") ( 8 ") 0 68 (") 6") ( ( ") 0mm (") MXIMUM WLL THICKNESS IN RE OF UNIT CLERNCE REQUIRED ROUND WLL OPENING FOR PROPER INSTLLTION OF TM 80 68 NOTE - WLL OPENING HEIGHT DIMENSION GRETER THN 68mm ( 6") MY EXCEED REQUIRED CUSTOMER RECH ND NOT MEET CCESSIBILTY REQUIREMENT GUIDELINES. 6 ") ( 6 ") ( HOLD THIS DIMENSION TO MEET REQUIRED CCESS REQUIREMENTS. SEE W LL OPENING HEIGHT NOTE # FILE NO. -68 REV. EXTERIOR ELEVTION NOTE - WLL OPENING HEIGHT INSIDE FLOOR LEVEL MUST BE THE SME S OUTSIDE SIDEWLK LEVEL FOR REQUIRED CCESS. IF INSIDE FLOOR IS HIGHER OR LOWER THN OUTSIDE, DIMENSION FOR LOCTING WLL OPENINGWILL HVE TO BE DJUSTED CCORDINGLY ND REQUIRED OPERTING HEIGHTS MY NOT BE MET FOR REQUIRED CCESSIBILITY STNDRDS. VERTICL SECTION

DIEBOLD 0 CSH DISPENSER REQUIRED MINIMUM SERVICE RES REQUIRED MINIMUM SERVICE RE LL ELECTRICL ND DT CBLES MUST ENTER UNIT IN THIS RE SHOWN IS THE REQUIRED MINIMUM RE FOR INSTLLTION ND SERVICE. DIMENSIONS SHOWN MY BE INCRESED WHEREVER POSSIBLE TO IMPROVE INSTLLTION ND SERVICE CCESS. USE OF NY RE LESS THN THE REQUIRED RE MY RESULT IN N INCRESE IN INSTLLTION ND SERVICE TIME. CONSULT WITH DIEBOLD INSTLLTION/SERVICE BRNCH FOR SPECIL BUILDING CONDITIONS. 8 ( 6 ") 0 SFE 8 THIRD NGLE "LL DIMENSIONS ND DESIGN CRITERI SUBJECT TO CHNGE W ITHOUT NOTICE" PGE OF 00 (8") 6 ") 6 ") ( 00 SFE 88 ( 6 ") (") 0 8 ") ( (6") ") ( (") 8 (") ( ") 0 (") ( ") (") ( ") 0 ( ") PLN VIEW 888 ( 6 ") ( 8 ") 0 (") (REQUIRED MINIMUM SERVICE RE) (8") 6 ") 888 6 ") ( 8 6 ") (68 FILE NO. -68 REV. SECTION (REQUIRED MINIMUM SERVICE RE)

8 ( ") SFE ( ") 8 (0 6 ") NOTES: SECURELY NCHORING THE TERMINL TO THE FLOOR: FOR PROPER SECURITY, IT IS REQUIRED THT THE TERMINL SFE BE SECURED TO THE FLOOR WITH NCHOR BOLTS. USE THE FOLLOWING GUIDELINES TO DETERMINE THE NCHORING METHOD FOR THE TERMINL. TO COMPLY WITH THE EUROPEN STNDRD EN - REGULTIONS, NCHORING CEN SFE TO WOOD FLOOR IS NOT PERMITTED. CEN SFE CN ONLY BE NCHORED TO CONCRETE OR STEEL FLOOR. THIRD NGLE 88 SFE (") 60 0 0 ") ( 8 ") ( ( 6") CBLE ENTRY OPENING (SEE NOTE) -NCHORING HOLES -SNP-OFF DETECTOR () mm ( ") RECESS DIMETER 8mm ( 6") RECESS DEPTH.mm (") THROUGH-HOLE-DIMETER 0 ( 6 ") (8 ") 68 0 6") ( 6") ( ( 6 ") PLN/SECTION CEN I SFE FLOOR 0 8 ") ( 8 6 ") ( ") ( () 6mm ( 6") RECESS DIMETER 8mm ( 8") RECESS DEPTH.mm (") THROUGH-HOLE-DIMETER M0 NCHOR BOLTS PROVIDED BY DIEBOLD MEETS/EXCEEDS THE FOLLOWING CEN NCHORING STRENGTH REQUIREMENTS WHEN PROPERLY INSTLLED: CEN L, I, II & III: CEN IV: 0 kn (PULLOUT FORCE) 00 kn (PULLOUT FORCE) NCHORING SFE TO CONCRETE FLOORS: THE TERMINL MUST BE NCHORED TO CONCRETE FLOOR OR CONCRETE BSE TO MEET CEN REQUIREMENTS. DIEBOLD WILL PROVIDE () M0 OR mm ( ") NCHOR BOLTS THT RE 0mm (8") LONG FOR PROPERLY SECURING THE UNIT. THE CONCRETE FLOOR/BSE MUST BE MINIMUM OF 0mm (") THICK FOR THE NCHOR BOLT TO BE EFFECTIVE (THERE IS NO LIMIT FOR MXIMUM THICKNESS). NCHOR BOLTS MUST BE USED IN LL VILBLE SFE NCHOR HOLES. NCHORING SFE TO STEEL FLOORS: TERMINLS INSTLLED ON STEEL FLOORS CN LSO BE SECURED BY MCHINE-THREDED NUT ND BOLT METHOD. IT IS PREFERBLE THT THE HRDWRE BE TTCHED THROUGH SUPPORTING STEEL POSTS OR BEMS FOR MXIMUM HOLDING CPCITY. DDITIONLLY, THIS HRDWRE MUST TTCH TO LOCLLY FBRICTED REINFORCEMENT PLTE INSTLLED UNDERNETH THE FLOOR TO PROVIDE DDITIONL STRENGTH. THE STEEL BCKING PLTE THICKNESS MUST BE T LEST mm ( "). THE MCHINE-THREDED NUT ND BOLT MUST BE USED IN LL VILBLE NCHOR HOLES. CEN L ND CEN I SFES: DIEBOLD TERMINLS WITH CEN L ND CEN I SFES RE EQUIPPED WITH LEVELING LEGS (FOR TRNSPORTTION PURPOSES ONLY) WHICH MUST BE RETRCTED BOVE THE BOTTOM OF THE SFE LLOWING IT TO SIT DIRECTLY ON THE FLOOR/BSE. THE OWNER S GENERL CONTRCTOR MUST PROVIDE SMOOTH ND LEVEL RE BELOW SFE SO IT CN BE INSTLLED PLUMB ND LEVEL. THIS WILL FCILITTE PROPER NCHORING OF THE SFE TO THE CONCRETE FLOOR/BSE. CBLE ENTRY SFE ( ") ELECTRICL ND DT CBLING ENTERS THE CSH DISPENSER THROUGH CBLE ENTRY OPENING ON THE SIDE OF THE SFE. CBLES ENTERING THE CSH DISPENSER PSS THROUGH THE POWER CBLE PLTE WHICH IS TTCHED TO THE INSIDE WLL OF THE SFE OVER THE CBLE ENTRY OPENING. CBLING CN ENTER FROM THE SIDE OR OPTIONLLY FROM UNDER THE CSH DISPENSER. THE CBLE ENTRY OPENING IS ON THE RIGHT SIDE OF THE SFE S VIEWED FROM THE RER OF THE CSH DISPENSER. PGE OF 8 ( ") 8 (0 6 ") mm ( 8") DI. HOLE FOR LRM CBLES (SIDE ENTRY) OPENINGS FOR POWER CORD ND DT CBLES (SIDE ENTRY) "LL DIMENSIONS ND DESIGN CRITERI SUBJECT TO CHNGE W ITHOUT NOTICE" 88 SFE (") 6 06 6") ( 6") ( CBLE ENTRY OPENING (SEE NOTE) 8 ") ( 8 6 ") ( ") ( POWER CBLE PLTE FILE NO. -68 REV. -NCHORING HOLES -SNP-OFF DETECTOR () mm ( ") RECESS DIMETER 8mm ( 6") RECESS DEPTH (8 ") PLN/SECTION CEN III or CEN IV SFE FLOOR.mm (") THROUGH-HOLE-DIMETER () 6mm ( 6") RECESS DIMETER 8mm ( 8") RECESS DEPTH.mm (") THROUGH-HOLE-DIMETER