Modulostar. Motor Branch 400V AC - 690V AC up to 11 kw

Similar documents
gg ferrule-style fuses

American Round Fuses - Form 101 range

V217276J /2 ATDR4-1/2 Z217786J 10 5 ATDR5 K218302J 10 6/10 ATDR5-6/10 Z218821J 10 6 ATDR6

NH Solid Blades 690 VAC sizes 000 to 3

FERRAZ SHAWMUT IS NOW. Fuses Fusegear

Semiconductor (AC) fuses

BS88 LV Fuse Links Catalog Blue Dot

Fuse-Links according to VDE 0670 T 402. Hi gh-voltage

Semiconductor Fuses European Fuses

onlinecomponents.com

High-Voltage Fuse Links according to IEC

gi-gl-gg, am gi-gl-gg gi-gl-gg NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories

gg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES

Medium voltage fuses - European Fuses

FUSE: SAFE & RELIABLE

Short Circuit. Sizes 0, 1, 2, and 690 Volt ratings - 32A through 630A All ratings include striker. 0% Lead

Semiconductor (AC) fuses

IEC fuse holders & fuse disconnectors: CMS 14

Switches. Fused Switches ITCP for Semiconductor Fuses 32 to 800A CONTROL: FUSE CONNECTING: SWITCHING: MECHANISM: FIXING: CONSTRUCTION:

SIRIUS Innovations. Technical information for ring terminals SIRIUS. Answers for industry.

Fuses for Semiconductor Protection - European Standard. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

High Power Switchgear. We can create a solution that s both effective and cost-effective

Miniature Fuses p. 226

D Type (DIAZED) FUSE-LINKS & SCREW CAP HOLDERS. EURO/IEC Fuses & Accessories 500 VOLT D TYPE DIAZED FUSE-LINKS, SCREW CAPS AND FUSE BASES

Helio Protection. Solar solutions designed by Ferraz Shawmut. Power generation & distribution.

Modulostar CMS10 Modular fuse-holders

RAPIDPLUS. high speed fuse links for semiconductors

IEC & 2. Fuse holders with indicator light. Poles N N M M C Z D213627

Protistor size 70 gr 690VAC (IEC)

1 Phase electronic contactor (SC 1)

RAPIDPLUS. high speed fuse links for semiconductors

Air-insulated switchgear UniGear type ZS1

A240R/A480R/A072F/A072B MED. VOLTAGE FUSES / R-RATED

AF40... AF96 3-pole contactors Technical data

Bulletin 190E/191E Direct On-Line Eco Starters

A240R/A480R/A072F/A072B MED. VOLTAGE FUSES / R-RATED

Starting Torque Limiter Type TCI (Soft Start)

EVpack-fuse MEV55 BATTERY PACK FUSES FEATURES & BENEFITS APPLICATIONS

Bulletin 190-M Compact Starters. Selection Guide

NH-Fuse system Low voltage

HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION. March 2017

3NP1 Fuse Switch Disconnectors up to 630 A

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

1.1 Caution Statements

G eneral Purpose Fuses

NH fuse-links am 690VAC top indicator/live tags size 4, 4a

Low-Peak 600V Class RK1

Application example of a motor controlled by MCD100 and protected by a circuit breaker

Protistor size 120 gr 750VDC (IEC)

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O

BS88 LV Fuse Links & Holders Catalogue Blue Dot

Components for EEx e Panels

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

MAKING MODERN LIVING POSSIBLE. Design Guide VLT MCD 100 Soft Starter the single speed drive

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

fuse-links & fuse holders PHOTOVOLTAIC

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

ULTRASAFE Fuse Holders The safety evolution continues.

IEC Low Voltage General Purpose Protection

Industrial Contactors CTX 3 3P 185A - 800A

HelioProtection Program

XT IEC Power Control Manual Motor Protectors

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Industrial contactors CTX-1

Micro Contactor MA Series

Essential equipment for all your requirements

Bussmann series NH catalogue. Leadership in circuit protection

YOUR ELECTRICAL SYSTEM IS YOUR LIFELINE AMP-TRAP 2000 FUSES

new NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price

Bulletin 193-T1 Bimetallic Overload Relays

Manual Motor Starters. Meta-MEC

Low voltage fusegear for cylindrical fuses. Fuse Holders Fuse Disconnectors Switch Disconnectors Fused Switch Disconnectors

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL)

EVpack-fuse MEV100 BATTERY PACK FUSES FEATURES & BENEFITS APPLICATIONS

BRANCH CIRCUIT PROTECTION FUSED COORDINATION PANELBOARD

CI-tronic Soft starters for Danfoss commercial compressor applications Type MCI 15C, MCI 25C, MCI 50CM-3 I-O

IEC Standard Back-Up Fuse-Links

Motor Protection Circuit Breakers 3VU13 and 3VU16

Softstarters Type PSS. Softstarters. General information

Semiconductor Fuses Microswitches & Studs

Receptacles & Wall Boxes

For 200V 3 Phase Motors 185. For 240V 3 Phase Motors 187. For 480Y/277V 3 Phase Motors 189. For 600Y/347V 3 Phase Motors 191. UL Listed CSA Certified

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence

NH HRC Fuses. IEC & British Standard Fuses NHG B

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3

FAMILY. 1-Phase 1 Up to 25A Up to 40A Up to 80A Up to 600VAC 3-Phase, 2 leg 1 No Up to 33A Up to 80A Gang 2 units

Medium Voltage Controllable Fuse

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

Leadership in Circuit Protection

FUSERBLOC CD. The universal Fuse Combination Switch FROM 20 TO 1250 A. Industrial Switching & Protection Systems

Gears & Fuse Gears. Medium Voltage Fuses Clips. Clip lock design for CL-14 series. Mounting Details for Clip Lock Cat. No.

Brochure. Motor protection and control DRAS enclosed direct-on-line starters

IEC and British Standard Fuses.

UltraSafe US22 Modular fuse-holders

Design Guide. VLT Soft Start Controller MCD 100

Leadership in Circuit Protection

NH DIN Dual Indication Fuse Links Class am, 690Vac, 6 to 500 Amps, Sizes 000 to 3 NH Series

INDUSTRIAL CYLINDRICAL FUSE LINKS

Special Purpose Fuses

Transcription:

Modulostar Motor Branch 400V AC - 690V AC up to 11 kw

Innovations in MODULOSTAR to control energy in motor starters Already active in the field of motor starters with rated current over 32A per phase, Ferraz Shawmut is innovating with the launch of two new products in the MODULOSTAR range: the CMSFM10 compact three-pole fuse holder and 10.3x38 690V fuses for motor systems. Modulostar Fuse system Protection against short circuits Motor Branch 400V - 690V AC Contactor Overlaod relay Switch-disconnector Power control Protection against overlaods Safety isolation (close to the motor) Motor Motor 45 mm In a typical motor starter set-up the advantages to using a fuse rather than a circuit breaker are obvious: Cost savings on maintenance, Better safety for workers and equipement with type 2 and 1 coordination as per IEC 947-4. Outstanding current limitation and very high interrupting rating MODULOSTAR is the name of our protection range built to IEC ferrule fuse standard. MODULOSTAR means compactness, high performance and innovation. It s a full range. Coordination in protection against electrical faults IEC standard 947-4 defines types of coordination: Type 1: the safety of people and property is ensured but there is still a risk of damage to the motor starter Type 2: the risk of damage is limited to the contacts on the contactors, which may be welded together Type 3: total coordination for zero risk CMSFM10 compact three-pole fuse holder The CMSFM10 is a compact three-pole fuse holder for 10.3x38 ferrule-style fuses, for use with contactors of the same compact size of 45mm (instead of 3x17.5 = 52.5mm for the CMS103). It is modern in design and made with brand new automatic manufacturing processes. A complete set of accessories is available. In particular, it is sold with a high performance, multifunctional wiring system. Cat Number Ref.Number U N I N Power loss in Watts I in Catalog Number means with a blown fuse indicator CMSFM10 S302765A 690 32 3 CMSFM10M T302766A 690 32 3 CMSFM10I W302768A 690 32 3 CMSFM10MI V302767A 690 32 3 M in Catalog Number means with a prebreaking microswitch

Accessories Catalog Number Reference Pack. PLUG TRI CMSFM PLUG TRI CMSFM B264041E 5 WIRING BAR 2 CMSFM C264042E 5 RAIL DIN ADAPTER CMSFM D264043A 1 WIRING CMSFM CONTACTOR E264044E 5 12,3 7 3,8 WIRING BAR 2 CMSFM 8 14 14 25 45 14,4± 0,15 14,4± 0,15 3,8 8 44 Model without microswitch Model with prebreaking microswitch 7 13 86,5 WIRING CMSFM CONTACTOR RAIL DIN ADAPTER CMSFM 10.3x38 690V am class fuses The MODULOSTAR range of ferrule-style fuses has been enlarged by the addition of 10.3x38 690V models for motors. This is a Ferraz Shawmut innovation. They provide a type-2 coordination as per the IEC 947-4 These fuses are available in ratings up to 16A to provide a fuse solution to needs for electrical protection of motor starters at any power level. Modulostar Current Un Power Motor Motor I motor Breaking In (A) Voltage dissipation power power (A) capacity Cat.Number Ref.Number (V) at In @ Un (Hp)* (kw) @ Un (ka) 1 690 0.1 0.5 0.37 0.65 80 FR10AM69V1 H302779J 2 690 0.16 0.75 to 1.5 0.55 to 1.1 0.75 to 1.6 80 FR10AM69V2 J302780J 4 690 0.3 2 to 4 1.5 to 3 2 to 3.8 80 FR10AM69V4 K302781J 6 690 0.35 5.4 4 4.9 80 FR10AM69V6 L302782J 8 690 0.45 7.5 5 6.6 80 FR10AM69V8 M302783J 10 690 0.55 10 7.5 8.9 80 FR10AM69V10 N302784J 12 690 0.7 13.5 10 11.5 80 FR10AM69V12 P302785J * 3-phase asynchronous motor 660V 1500 rpm for Un motor = 400V you have to derate for the same fuse rating use a motor with lower power (factor= 0.58 to 0.65). The table provides the current rating of fuse for standard starting conditions i.e. 2 starts per day at 6In 2 seconds for a 3-phase motor at 1500 rpm @ new IEC voltages 400V and 690V. For a 3000 pm motor speed the rating is the one published here with a coefficient factor between 0.8 and 0.95.

Other Ferraz Shawmut products Protistor A fuse provides a perfectly suitable solution for all possible configurations, in particular when used with drives and soft starters. In such cases the CMSFM fuse holder with gr class PROTISTOR fuses provides effective protection for the whole set-up. Our grb range provides a type-3 coordination as per the IEC 947-4. Soon a new range of gs class PROTISTOR ferrule-style fuses will be added to the choice of solutions, providing all the advantages already offered by gs class NH PROTISTOR fuses, i.e. the unmatched performance of the PROTISTOR fuse, reliable I²t, protection from any kind of overload, and no thermal derating in standard fusegear. Current Catalog Number Reference Motor power Motor power I motor @ 690V (HP) (kw) (A) 1 FR10GB69V1 Z330279 0.12 0.09 0.15 1.25 FR10GB69V1.25 X330001 1.5 FR10GB69V1.5 Y330002 0.18 0.13 0.2 2 FR10GB69V2 Z330003 2.5 FR10GB69V2.5 A330004 0.25 0.18 0.28 3 FR10GB69V3 B330005 0.37 0.27 0.42 4 FR10GB69V4 C330006 0.50 0.37 0.57 5 FR10GB69V5 D330007 0.55 0.40 0.6 6 FR10GB69V6 E330008 0.75 0.55 0.85 8 FR10GB69V8 F330009 1 to 1.5 0.74 to 1.1 1.2 to 1.6 10 FR10GB69V10 G330010 2.2 1.6 2 12.5 FR10GB69V12.5 H330011 3 to 3.8 2.2 to 2.8 2.8 to 3.5 16 FR10GB69V16 J330012 4 2.9 4.3 20 FR10GB69V20 K330013 4.5 3.3 4.9 to 6.6 25 FR10GB69V25 L330014 5.5 to 7.5 4 to 5.5 30 FR10GB69V30 M330015 8.9 to 11.5 32 FR10GB69V32 Y330278 10 to 13.5 7.5 to 10 Voltage Rated Pre-arcing I²t Total I²t at Dissipated power Peak arc Breaking Rating current I²tp (A²s) 660VAC at In at 0.8 In voltage capacity (VAC) In (A) I²tt (A²s) (W) (W) (V) I (ka) Motor Branch 400V - 690V AC 690 1 0.075 0.28 0.9 0.52 2500 160 ka 690 V (IEC) 690 1.25 0.115 0.36 1.25 0.7 2500 160 ka 690 V (IEC) 690 1.5 0.185 0.57 1.5 0.81 2500 160 ka 690 V (IEC) 690 2 0.42 1.3 2 1.1 2500 160 ka 690 V (IEC) 690 2.5 0.88 2.7 2.1 1.15 2500 160 ka 690 V (IEC) 690 3 1.55 4.6 2.3 1.25 2500 160 ka 690 V (IEC) 690 4 4 12 2.6 1.35 2500 160 ka 690 V (IEC) 690 5 8.6 25 2.7 1.4 2500 160 ka 690 V (IEC) 690 6 15 44 2.9 1.5 2500 160 ka 690 V (IEC) 690 8 3.3 33 2.4 1.35 1450 160 ka 690 V (IEC) 690 10 5.4 55 3.4 1.85 1450 160 ka 690 V (IEC) 690 12.5 8.5 82 3.4 1.9 1450 160 ka 690 V (IEC) 690 16 16 145 4.1 2.3 1450 160 ka 690 V (IEC) 690 20 230 250 4.3 2.4 1450 160 ka 690 V (IEC) 690 25 58 470 4.7 2.7 1450 160 ka 690 V (IEC) 690 30 96 740 5 2.9 1450 160 ka 690 V (IEC) Refer to the prescription document on drives and soft starters.

Modulostar 10.3x38 400 and 500V am class fuses The Modulostar range of ferrule-style fuses also includes 400 and 500V rated models. They provide a type-2 coordination as per the IEC 947-3. Current Voltage Power Motor Motor Breaking In (A) (V) dissipation at In power power capacity Cat.Number Ref.Number @ Un (Hp)* (kw) @ Un (ka) Motor Branch 400V - 690V AC 0.16 500 0.35 120 FR10AM50V0.16 E214617J 0.25 500 0.50 120 FR10AM50V0.25 M215130J 0.5 500 0.13 0.135 0.1 120 FR10AM50V0.5 W216150J 2 500 0.20 0.75 0.55 120 FR10AM50V2 H218714J 4 500 0.30 2 1.5 120 FR10AM50V4 W219232J 6 500 0.45 3 2.2 120 FR10AM50V6 F222208J 8 500 0.55 4 3 120 FR10AM50V8 Z211553J 10 500 0.65 5.5 4 120 FR10AM50V10 Y211552J 12 500 0.75 7.5 5.5 120 FR10AM50V12 D214110J 16 500 0.90 10 7.5 120 FR10AM50V16 P215132J 20 500 1.10 11.1 8.5 120 FR10AM50V20 X216151J 25 400 1.40 13.5 10 120 FR10AM50V25 L217682J 32 400 2.0 120 FR10AM40V32 J218715J * 3-phase asynchronous motor 400V 1500 rpm The other MODULOSTAR fuse holders for 10.3x38 ferrule-style fuses can be used in motor starter systems. Cat Number Ref.Number U N I N Power loss in Watts CMS101 T305020K 690 32 3 CMS101I A305026K 690 32 3 CMS103I D305029D 690 32 3 CMS103 X305023D 690 32 3

Our ITC fused switch disconnector line is also designed to be mounted in motor starter systems. Cat Number Ref.Number U N I N Power loss in Watts ITC32S3CF J205283A 1000 32 3 ITC32S3NCF K205284A 1000 32 3 ITC32S4CF L205285A 1000 32 3 To get the full benefit of our fusegear, don t forget Fuse Monitoring to help seek out the fault and reduce the time spent by maintenance or repair people. FUSE MONITORING: LOCATING A FAULT MADE EASY! Simplicity itself! Green LED on: Power on and fuses operational No LED on: Power off Red LED on: One or more blown fuses Ask us for our literature on Fuse Monitoring (ref. GP011) For more details on our Fuse Monitoring offering refer to our brochure GP009. Ferraz Shawmut SAS - 1, rue Jean Novel 69626 VILLEURBANNE Cedex - FRANCE Tél. 33 (0)4 72 22 66 11 - Fax 33 (0)4 72 22 67 13 Ferraz Shawmut Inc. - 374 Merrimac Street Newburyport, MA 01950 - USA Tél. (978) 462-6662 - Fax (978) 462-0181 www.ferrazshawmut.com Studio Amalgame - OM001-04/2007