FUSE: SAFE & RELIABLE

Similar documents
FUSERBLOC CD. The universal Fuse Combination Switch FROM 20 TO 1250 A. Industrial Switching & Protection Systems

FUSES. Safety through quality

Power systems Protection course

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Fuses still the best form of overload protection

Low Voltage Apparatus. Technical Brochure. FuseLine HRC Fuse Links OFAA, OFAM. Brochure OF 1 GB ABB Control Oy

Cascading & Discrimination

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

3.2. Current Limiting Fuses. Contents

Sentry Technical. Miniature Circuit Breakers (MCBs) Standards and approvals. Description. Technical specification

Miniature Circuit-Breakers (MCBs)

MAGNETIC MOTOR STARTERS

Semiconductor Fuses European Fuses

onlinecomponents.com

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction.

Modulostar. Motor Branch 400V AC - 690V AC up to 11 kw

Miniature circuit breaker Application guide

HHD HIGH VOLTAGE FUSES GERMAN DIN STANDARD. The temperature limiting function of the fuse striker pin. Design and construction.

Advanced Guide To Understanding Assembly Short-Circuit Current Rating WITH ENGINEERING SOLUTIONS AND OVERCURRENT PROTECTION DEVICES TO ENHANCE SCCR

NEW SERIES OF ETIBREAK EB2 IN VIEW OF SELECTIVITY

Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A

Low Voltage Fuses For Motor Protection

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Paramount HRC Cartridge

EE 741 Over-voltage and Overcurrent. Spring 2014

Simplified Guide To Understanding Short-Circuit Current Rating FIND IT, FIX IT, FORGET IT

Exercise 1-5. Current Protection Devices EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Circuit breakers

Bussmann series NH catalogue. Leadership in circuit protection

Miniature Circuit-Breakers (MCBs)

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

Electrical Protection

NH-Fuse system Low voltage

Installation Manual for DC Injection Brake Units

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

Fuseology. Dual-Element, Time-Delay Fuse Operation

Fuseology. High Speed Fuses

Selective main circuit breakers S 750 series Technical Data

ACS motor protection circuit breakers KT 7 Introduction

1. Design, function and types of circuit breakers 1.1

Current Ratings. Standards & codes note 1. Introduction. interest. By Steve Hansen Sr. Field Engineer

Product brochure. ABB Fusegear EasyLine Fuse switch disconnector

NEXT STEP B) SAFETY :

NH Solid Blades 690 VAC sizes 000 to 3

Medium voltage products. Fuses

ECET Distribution System Protection. Overcurrent Protection

UL248 North American Low Voltage Fuses

Amp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. Class J / AJT...A2. AJT Reducer Fuses...

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

Motor Protection Circuit Breakers 3VU13 and 3VU16

Direct On Line (DOL) Motor Starter. Direct Online Motor Starter

Devices for Branch Circuits and Feeders

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

Don t Discriminate: The importance of selective coordination in electrical installations

HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION. March 2017

Table 1.-Elemsa code and characteristics of Type K fuse links (Fast).

Pretest Module 29 High Voltage Unit 1

Industry Automation Control Components

EUROFUSE MULTIBLOC MULTIVERT D/D0-FUSE-SYSTEM BSL NH-FUSE-MATERIAL MULTIFIX 60 CYLINDRICAL FUSE-SYSTEM MINIATURE FUSE LINKS HIGH VOLTAGE FUSE LINKS

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

ACHIEVING MAXIMUM BENEFITS WITH A FUSE PROTECTED MOTOR CONTROL CENTER

For Type 2, No Damage circuit protection in all the configurations you need. A Amp-Trap 2000 Fuses

What's New with UL508A Codes & Standards Presented by Jeff Woolfolk Manufacturing in America March 14-15, 2018

YOUR ELECTRICAL SYSTEM IS YOUR LIFELINE AMP-TRAP 2000 FUSES

High-voltage high-breaking capacity VV fuse-links

ETAP Implementation of Mersen s Medium Voltage Controllable Fuse to Mitigate Arc Flash Incident Energy

Presented to the IAPMO Standards Review Committee on December 9, 2013

Overcurrent protection

Low Voltage A GE Power Controls Company. General catalogue

GE Power Controls. Low Voltage HBC Fuselinks. For more information, please contact: MAJESTIC GLOBAL LTD.

Fusing Equipment. Kearney Fuse Links. general. Internal Construction. tin element

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

Joslyn Clark Controls, Inc. Simple, Safe, Retrofit Programs to Significantly Extend Life of Existing Circuit Breakers

Semiconductor (AC) fuses

Limitor -G General Purpose Fuses

Miniature Circuit Breaker

Self-protected Combination Starters System PKZ 2-SP

Kearney fuse links. Technical Data General. Effective March 2014 Supersedes December 2013

Kearney fuse links. Technical Data General. Effective December 2013 Supersedes November 2009

Effective discrimination of protective devices

MAHALAKSHMI ENGINEERING COLLEGE TIRUCHIRAPALLI

Selecting Protective Devices

Secondaries. arc flash note Introduction. By Mike Lang, engineer and. Services Supervisor

201 S. Anaheim Blvd. Page No Anaheim, CA RULE NO. 2 DESCRIPTION OF SERVICE

Use of switch-fuse combinations at the medium-voltage level for the protection of distribution transformers siemens.com/tip-cs

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

Technical Section: Miniature Circuit Breakers

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

Catalogue March InLine II - ZLBM/ZHBM Fuse Switch Disconnector

High voltage high-breaking capacity VV fuse-links

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

Leadership in Circuit Protection

Low Voltage Industrial Type T Fuse Links

Low-Peak 600V Class RK1

ES5 Security Theory/Regulations Answer Schedule

1 Phase electronic contactor (SC 1)

Medium voltage products. Fuses

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

Reducing. with Current. arc flash note 2. points of interest. Why Use Current Limiting Fuses. By mike lang, Principal field engineer

Special Purpose Fuses

ECET Circuit Design Motor Loads. Branch Circuits. Article 210

Transcription:

FUSE: SAFE & RELIABLE VS. CIRCUIT BREAKER Tech Topics: Selective Coordination Note 2, Issue 1 Franck Charlier Technical Support Engineer Points of interest: Power fuse needs no repair only to be replaced Power fuse improves the power quality in the system Selectivity is easy to manage between current limiting fuses In an industrial set-up the odds are clearly stacked in favor of the fuse. Safer, cheaper and more flexible when an installation changes, the fuse is the obvious choice for circuit protection. High operating voltages, many different lengths of wires and cables, and often widely varying feeders in the electrical configuration make an industrialscale electrical layout very different from a residential installation. While the circuit breaker is undeniably the leading component in residential applications to protect against short-circuit currents and overloads, the fuse offers unquestionable advantages for equipment and installations in the industrial world. Fast acting Up to 300,000 A The capacity of fuses to break short-circuit currents is nothing short of extraordinary. Some industrial-scale fuses can clear currents up to 300,000 amps! Lower cost When everything is considered purchase price, maintenance cost, foreseeable service life a fuse proves to be much more economical than a circuit breaker. And that gap rapidly widens at higher ratings! Breaking capacity If only one property of fuses could be considered, it would have to be the exceptional speed with which they react to a fault. A few milliseconds are enough for a fuse to completely clear a short-circuit current, while the fastest circuit breaker in the limiter line takes 3 times as long. A more ordinary type of circuit breaker may take 30 times as long! Breaking capacity is defined as the highest short-circuit current the protective device is capable of stopping. Despite the undeniable progress made in the past few years, the circuit breaker soon shows its limits! For circuits running at 690V, a circuit breaker s breaking capacity is much too low to guarantee an installation s safety: while short-circuit currents may hit peaks of 100,000A at that voltage, a circuit breaker s breaking capacity may be less than 10,000A, which is clearly insufficient. CMSFM10 p1 TT-SC2-001-0604: Fuse: Safe & Reliable vs. Circuit Breaker FERRAZ SHAWMUT IS NOW MERSEN

Safe Safety is the vital feature of electrical equipment and installations. We re talking here about the safety of the men and women working around and on that equipment. The very principle on which fuses operate argues in their favor. Inside the fuse body, a specially designed metal element melts down when current is too high. Nothing happens outside the fuse because the electrical arc created when the element melts is confined inside it and the energy is absorbed by the sand filling. Both people and property have a better guarantee of safety when an installation is equipped with fuses, as there is no risk whatsoever of equipment and machinery suffering any deterioration. Discriminating Fuses are highly discriminating, as the fuse that is the smallest and closest to the short-circuit can act on the fault without involving any higher rated fuses up-line. With circuit breakers a system of selective coordination can be devised but is often difficult or even impossible to set up for shortcircuit currents. MULTIBLOC 000.ST8 A word about maintenance Again, there s a big difference between fuses and circuit breakers. Circuit breakers must be checked regularly to make sure the contacts are in good condition and the device operates correctly, while the fuse s extremely stable nature requires no work at all. After a fuse has blown to clear a short circuit, it is simply removed and replaced with a new fuse, whereas a circuit breaker may need repair. For models with high current ratings, any parts that are damaged in operation must be replaced. Smaller ones may have to be entirely replaced after operating once or twice to deal with a fault. All that has a cost! p2 TT-SC2-001-0604: Fuse: Safe & Reliable vs. Circuit Breaker

Relative advantages CIRCUIT-BREAKERS ( mechanical moving parts ) Although dimensions are standardized, there are many different tripping characteristics and forms of arc dispersion to the outside which complicates selection and replacement. MCBs have non adjustable characteristics, but up to 4 different type are available Low performances Hot ionized gases can be emitted to the outside (safety area needed) International standardization means simplicity Fault current Current (I N ) Nominal voltage (U N ) Reliability Selectivity FUSES ( Nothing can prevent the fuse from blowing ) (Joule effect) IEC 60269 have electrical unit dimensional characteristics which make them fully interchangeable High performances Safe operation Confined arcing Safely within the sealed cartridge Markets General market User convenience ==> Domestic = Circuit-breakers - Lower breaking capacity. - Normally tested with additional length of cable Demanding market Reliability ==> Industry = Fuses - Have unrivalled ability to clear high fault currents safely. Breaking capacity up to 50 100 200 ka are common under the severest testing conditions. - This means that detailed fault level calculations are not necessary. The fuse can do it! p3 TT-SC2-001-0604: Fuse: Safe & Reliable vs. Circuit Breaker

Comparison of motor starters Fuse Fonction Circuit-breaker Fuses Switch fuse isolation Short-circuit protection Both polarities isolator of fuses Circuit-breaker Contactor Contactor Power control Current transformer Overload relay Overload protection Switch disconnector Switch disconnector Motor Safety isolation (near Motor) Motor Motor Type 2 Co-ordination (IEC60947-4) Type 1 Type 2 co-ordination shall be insured in order to comply with the safety rules (people and equipments). The fuse limits the peak current and let through I²t to levels below the withstand of the contactor and overload relay. In case of motor starters with circuit-breaker protection, the contactor shall be over sized to carry the peak current through limiting breaker. p4 TT-SC2-001-0604: Fuse: Safe & Reliable vs. Circuit Breaker

Co-ordination test according to IEC60947-4 The tests for fuse protected starters Possible consequences for wrong coordination The tests for circuit breaker protected starters Test 1-30 ka Test 50 ka Test < 10 le 1. The peak let through current of the contactor leads to : light welding of the contactor contacts, damages of the arc chambers. Test 1-30 ka Test 50 ka 2. The short circuit withstand current of the bimetal relay : exceeds maximum motor acceptable value burns the bimetal relay 3. The peak let through current or I²t in the circuit generates high electrodynamics compulsions, high temperature rise (joule effect) For both fuses and breakers Co-ordination type 1 : The starter and the contactor may be damaged. Co-ordination type 3 : The starter must be faultless after the tests. Co-ordination type 2 : The starter must be operable after the tests whatever high its prospective current may be. Only light welding of the contactor is allowed. Achievable with fuses whatever the contactor manufacturer is. With circuit-breaker, it is necessary to conduct tests and adjustments according to the manufacturer products. p5 TT-SC2-001-0604: Fuse: Safe & Reliable vs. Circuit Breaker

Current limiting and let through energy Current limiting with standard breaker. Current limiting with limitor option breaker. Natural current limiting with fuses. High and wide peak let through current of the circuitbreaker The size of the contactor and overload relay must be selected in proportion to the current limiting level of the breaker (Typical let through I²t levels are about 10 20 times higher than a fuse) Short and low let through current and very low I²t of the fuse. The short circuit capacity of the contactor and overload relay is normally adequate for the let through energy. Current limiting fuses clear short-circuit fault in less than a half-cycle, improving the "power quality" in the system. Current limiting breakers operate within one half cycle but the operating time is much longer than for a fuse and the improvement in "power quality" is less marked. p6 TT-SC2-001-0604: Fuse: Safe & Reliable vs. Circuit Breaker

Selectivity Fuses: Excellent discrimination (selectivity) for all currents Breakers: Selectivity ensured for low currents Standard melting curve IEC 60269-1 and 2. Always mechanical delay. Selectivity ratio = 1.6 / 1 with gg fuses. Selective when rated current of the fuse on supply side is one or two sizes higher than on load size. Specific let through energy in high currents is small. Contactor and thermal relay are not critically stressed. Selectivity for high currents require specific calculations (often impossible to achieve). Time delay device improves selectivity only up to 15 times the rated current of the supply side breaker (selectivity ratio > 2.5/1 and usually 4/1 needed according characteristics). p7 TT-SC2-001-0604: Fuse: Safe & Reliable vs. Circuit Breaker

Selectivity Fuse / Circuit-breaker Require rated current higher for breaker than fuses (generally more than 3 times to be controlled with instantaneous (Lim triggering action). In this case the selectivity is not possible on the full range of currents ; the fuse will blow for high prospective currents. In some cases, the fuses will permit to use low breaking capacity breaker (all currents higher than Ip1 will be eliminated by fuse which has a very high breaking capacity). p8 TT-SC2-001-0604: Fuse: Safe & Reliable vs. Circuit Breaker

Reliable isolation Cost difference in use When a fuse is removed from its holder or a switch fuse is operated "effective isolation" as required by IEC 60364 (wiring regulations) is achieved. In each case, when the fuses are removed, the circuit is open and the tripping distance is high. So that it is safe for persons to work on the downstream circuit. Cost Cost difference Breaker In addition, Mersen ITC and ITCP have reliable isolation on both sides of the fuse and the isolation has a visible point while fuses are removed. Theses increases safe operation for maintenance staff. Installation of a class AC22 or AC23 circuitbreaker, (break visible) or a class AC20 switch with a switching adjacent to the motor or the machine, with perfect security in the event of interference. Number of short circuits Fuses Quick replacement (always three fuses on one circuit) Low spare part costs Ready for use after replacement Circuit-breaker Plug-in version is needed for quick replacement More costly spare part stock Require settings before use The new machine regulations impose a switch with pe-breaking contact or a circuit-breaker to separate the energies (Clause R233-29), the electrical risks (Clause R233-25), the voluntary action of putting into operation (Clause 233-18). Only circuit breakers with a certain minimum contact separation will give effective isolation in accordance with the regulations. The case of reclosing a breaker ineveases the risk of accidental reenergisation of the circuit. p9 TT-SC2-001-0604: Fuse: Safe & Reliable vs. Circuit Breaker

Performance and life time costs Fusegear Breaker Costs Performance en % Costs Performance en % Investment 1.0 100 % 1.2 100 % Failure n 1 0.1 100 % 0 80 % Failure n 2 0.1 100 % 0 60 % Failure n 3 0.1 100 % 1.2 100 % Safe replacement after operation The system protection is restored to its original state. Fuse totally closed : Safe in minimum installation space Long term protection perfect in various environmental conditions. Performance level drops in use Not totally closed : Space for overpressure needed Smooth functioning must be skiller regular testing After a fault has occurred the cause of the fault must first be identified and then corrected. The fuse can be changed at this time. Breaker must be changed after 2-3 major short-circuits with identical product (position of the venting on it not standardized). p10 TT-SC2-001-0604: Fuse: Safe & Reliable vs. Circuit Breaker

Security if fault level increase Electrical distribution net works grow with the addition of extra breakers and equipment : eg. Second transformer is connected in parallel ==> required higher breaking capacity devices. No problem with fuse system (breaking capacity between 100 and 200 ka). The breaking capacity of the breaker itself can be exceeded. In either case the breaker needs to be replaced with a more suitable type, or a fuse must be fitted to provide back-up protection of the breaker. Present Situation Future Situation Protection of cables gg fuses to IEC 60-269 give complete over-current protection of cables in accordance with the international wiring regulations (IEC 60364) In accordance with IEC 60364 the section of the cables wire protected by fuses must be increased by 10 % (in comparison with circuit breaker protection with adjustable current). On the other hand, this difference of section desapears in the following cases. Variation higher than 4% on the voltage supply Extensions Power losses calculated in the longer cables : Ex : 50 m of 10 mm² cable for 60 A circuit == > R = 90 mohms == > power losses = 3900 kw / year 50 m of 16 mm² cable for 63 A fuses ==> R = 56 mohms ==> power losses = 2400 kw / year (depreciation in 4 years) PN = 1250kVA U CC = 4% PN = 1250kVA U CC = 4% Modern a fuses are tested at 1,3 IN in accordance with IEC 60269-2-1 standard Annexe and in order to have the same rating calculation than Circuit Breakers I CCA = 36,1kA I CCB = 36,1kA I CCA = 72,2kA I CCB = 72,2kA Circuit breakers can also provide low overcurrent protection of cables, but protection against shortcircuit is only provided below a certain fault level p11 TT-SC2-001-0604: Fuse: Safe & Reliable vs. Circuit Breaker