I-VICFLEX.AB5. Victaulic VicFlex Style AB5 Sprinkler Fitting for Wood or Metal Joists/Studs and CD Profile (60 mm) Channel Ceiling Systems WARNING

Similar documents
I-VICFLEX.AB11. Victaulic VicFlex Style AB11 Low-Profile Sprinkler Fitting for Suspended Ceiling Systems WARNING INSTALLATION INSTRUCTIONS

I-VICFLEX.AB1/AB2/AB10

I-VICFLEX.AB7 VicFlex Sprinkler Fittings for Ceiling Suspension Systems STYLE AB7

I-795/906. Series 795 and 906 Installation-Ready Knife Gate Valves WARNING INSTALLATION AND MAINTENANCE INSTRUCTIONS

Data Sheet 3.11 Issue F

Data Sheet 3.03 Issue D

Data Sheet 3.01 Issue C

I-731-D/W731-D. Suction Diffuser. Important Installation Information. series 731-D and W731-D

I-232.T3S2 Victaulic Style 232 Restrained, Flexible High-Pressure Coupling

I-234. Victaulic Styles 234/234S Restrained, Flexible Single-Gasket Couplings WARNING IMPORTANT INFORMATION ITEMS PROVIDED WITH SHIPMENT:

Model VKFD28 Flexible Sprinkler Drops (LPCB Approved) Installation Manual. January 2016 Form No. F_ Rev 16.1

I-799/79V Coil Components

I-231.T2S1/CLAD. Victaulic Style 231 Non-Restrained, Flexible Expansion Coupling with Cladding on Expansion Side of Pipe WARNING IMPORTANT INFORMATION

FRAME STYLE SPRAY NOZZLES TECHNICAL DATA

GROOVED COUPLINGS - STANDARD FLEXIBLE Model 101

I-317. AWWA Check Valves WARNING INSTALLATION AND MAINTENANCE INSTRUCTIONS SERIES 317 WARNING

TECHNICAL DATA OBSOLETE

Flexible Sprinkler Connector Braided & Unbraided

Easy Riser swing check valve Models E-1 & F-1

TECHNICAL DATA OBSOLETE

TECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P)

model E Spray nozzles vk810 - vk817

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE 6 (DN150)

mirage standard and Qr concealed pendent sprinkler vk462 and hp sprinkler vk463 (K5.6)

I-VIC300MS. Series 761 Vic-300 MasterSeal Carbon Steel Butterfly Valve Series 461 Vic-300 MasterSeal Stainless Steel Butterfly Valve WARNING

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

TECHNICAL DATA. Q= C v P S

Document: 3 inch Vane Pump System-in-a-Box Assembly Instructions SPS100370

Fire Protection Systems

Instructions for Installation, Operation, Care and Maintenance

Grooved Piping System for Fire Protection Services

Flexible Sprinkler Connections

Rosemount 285 Annubar Pak-Lok Assembly

TECHNICAL DATA 1-1/2 (dn40)

TECHNICAL DATA SPRINKLER ESCUTCHEONS

Listings and Approvals. G5 QR Gasket culus QR G5 SR Gasket culus, FM SR G5

TECHNICAL DATA. Table 1: Model F1 Dry Valve Part Numbers and Specifications

INSTALLATION/OPERATION/MAINTENANCE INSTRUCTIONS FOR ARCHON MODELS WD2010L, WD2010, WD2010H WASHDOWN STATIONS. ARCHON Industries, Inc.

Fisher 657 Diaphragm Actuator Sizes and 87

I-VIC300MS. Vic -300 MasterSeal Butterfly Valves WARNING SERIES 761

B U I L D I N G C O N N E C T I O N S T H AT L A S T

TECHNICAL DATA. model f-1 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA. Page 1 of 11

30.85 FireLock NXT Actuated Valve with LPCB Approved Preaction Trim

Rosemount 485 Annubar Flanged Assembly

Model DF233 Control Valve

B21 Series BASOTROL Gas Valve

Baumann Series Flexsleev Control Valve Instructions

Victaulic Fittings, Couplings, Valves & Sprinkler Heads for the Fire Sprinkler Market Keeping the art of distribution simple

Instructions for Installation, Operation, Care and Maintenance

I-NXT.RBKIT 5-Year Rebuild Kit Instructions for FireLock NXT Valves

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

Grinnell Grooved Fire Protection Products Grooved Fittings

REQUEST PUBLICATION 18.11

Model DF269 Control Valve

Model CV-1FR Grooved-End Riser Check Valves 2 Inch to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data

Signet 2517 Brass Paddlewheel Flow Sensor * *

Instructions for Installation, Operation, Care and Maintenance

TECHNICAL DATA CAUTION

Audi-Larm TM Audible Alarm: AirHawk II Air Mask

Speed Controller with One-touch Fitting

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

2013 IMPCO Technologies, Inc. Page 1 of 20 EPR Repair Kit Instructions (PPI-122, Rev-B)

DeZURIK " BAW AWWA BUTTERFLY VALVES WITH EPOXY-RETAINED SEAT

DEFENDER SERIES. 5 Gallon, Double Walled, Field Replaceable Spill Container Model Series INSTALLATION, OPERATION, & MAINTENANCE

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

RG2100 Roll Grooving Tool

Maintenance Instructions

Scope. Applicability. Caution. I & M CV3000 Series. Storage. Installation & Maintenance Instructions for Marwin CV3000 Series Three Piece Ball Valves

TECHNICAL DATA VK810 (65 ) VK811 (80 ) VK812 (95 ) VK813 (110 )

Speed Controller with One-touch Fitting

McCannalok HIGH PERFORMANCE BUTTERFLY VALVE OPERATION AND MAINTENANCE MANUAL. The High Performance Company

FireLock NXT Deluge Valve. With Deluge Trim Grooved x Grooved. System No. Submitted By Spec Sect Para Location Date Approved Date

Baumann Way Control Valve

KOFULSO /Easyflex flexibles sprinklers drop distributed by

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

I-BFV.KIT Butterfly Valve Gear Operator Replacement

Escape Cylinder and Valve

155 CARTRIDGE SINGLE SEAL

Operation & Service Manual

Directional Spray Nozzles, Open, with Strainers High Velocity General Description

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Model RM-1 Riser Manifold Commercial and Residential General Description

Cylinder and Valve: AirHawk II Air Mask

Size Inches UL ULC FM. Pipe Sch.

Hole-cutting. cutting a hole. After the hole has been cut all rough edges must be removed and the area within 5/8 (16mm) of the hole

Page 1 of 26 Oteco Inc. Houston, Texas

Installation Operation Maintenance. LSSN Butterfly Valve AGA Approved 50MM - 150MM. QAD#IM6055.REVA

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components

ONYX VALVE CO MODEL CER and CEP Installation & Maintenance

Grooved Piping System for Fire Protection Services

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

Baumann 24000C Carbon Steel Little Scotty Control Valve Instructions

AIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS

Rosemount 485 Annubar Threaded Flo-Tap Assembly

Type EA-1 PROTECTOSPRAY Directional Spray Nozzles, Automatic, Medium Velocity General Description

IOM Manual. IOM Manual. Series 76/77.

270PK SERVICE GUIDELINES

Bray/ VAAS Slurry Series Knife Gate Valve 760/762/765/766/767/768 Series Operation and Maintenance Manual

VSI INDUSTRIAL BALL VALVES SERIES 7100 SERIES 8100 SERIES 7200 SERIES 8300 SERIES 7400 SERIES 8400 SERIES 8000 SERIES 8500

Transcription:

INSTALLATION INSTRUCTIONS I-VICFLEX.AB5 Victaulic VicFlex Style AB5 Sprinkler Fitting for Wood or Metal Joists/Studs and CD Profile ( mm) Channel Ceiling Systems WARNING Read and understand all instructions before attempting to install any Victaulic VicFlex products. Wear safety glasses, hardhat, and foot protection. These installation instructions are intended for an experienced, trained installer. The installer shall understand the use of this product and why it was specified for the particular application. The installer shall understand common industry safety standards and potential consequences of improper product installation. It is the system designer s responsibility to verify suitability of stainless steel flexible hose for use with the intended fluid media within the piping system and external environment. The material specifier shall evaluate the effect of chemical composition, ph level, operating temperature, chloride level, oxygen level, and flow rate on stainless steel components to confirm system life will be acceptable for the intended service. Failure to follow these instructions could cause improper sprinkler operation and product failure, resulting in death or serious personal injury and property damage. Flexible Hose Listing and Approval Information Flexible Hose G10 10l AH1 With AB5 With AB5 With AB5 With AB5 With AB5 AH1-LP With AB5 With AB5 AH1-CC With AB5 With AB5 With AB5 With AB5 AH1-CC-LP With AB5 With AB5 AH With AB5 With AB5 With AB5 With AB5 With AB5 AH-LP With AB5 With AB5 AH-CC With AB5 With AB5 With AB5 With AB5 AH-CC-LP With AB5 With AB5 AH-00 With AB5 AH-68 With AB5 AH* With AB5 With AB5 With AB5 AH-LP* With AB5 With AB5 AH* With AB5 AH-LP* With AB5 * SERIES AH, AH-LP, AH, AND AH-LP REGIONAL AVAILABILITY ONLY NOTES: Victaulic VicFlex flexible hoses are City of Los Angeles (RR5659) Approved, accepted for use by the City of New York Department of Buildings (MEA -05-E), and have the OSHPD Pre-Approval (OPA-55-07). Flexible hoses are available in lengths from 1-7 inches/787-189 mm with either 1/-inch/DN15 or /-inch/dn0 NPT or BSPT threaded outlets. I-VICFLEX.AB5_1

Maximum Working Pressure Rating of Flexible Hose: 00 psi/1 Bar/179 kpa (FM) 175 psi/1 Bar/107 kpa (UL) 16 Bar/10 kpa/ psi (VdS and LPCB) 1. MPa/100 kpa/0 psi (CCCf) 00 psi/1 Bar/068 kpa (FM Series AH-00) Maximum Ambient Temperature Rating of Flexible Hose: 5 F/107 C (UL, FM, VdS, LPCB) 15 C/75 F (CCCf Series AH) Connection to Sprinkler Piping: 1 inch/dn5 NPT/BSPT (UL, FM, CCCf) 1 inch/dn5 IGS (UL, FM, VdS) DN0// inch BSPT (VdS) DN/1 1/ inch BSPT (LPCB) Minimum Bend Radius of Flexible Hose: inch/76 mm (UL Series AH1, AH1-CC) inch/50 mm (UL Series AH, AH-CC) 7 inch/178 mm (FM Series AH1, AH1-LP, AH1-CC, AH1-CC-LP, AH, AH-LP, AH-CC, AH-CC-LP, AH-68, AH, AH-LP, AH, AH-LP) 76 mm/ inch (VdS Series AH1, AH1-LP, AH1-CC, AH1-CC-LP, AH, AH-LP, AH-CC, AH-CC-LP, AH, AH-LP) 76 mm/ inch (LPCB Series AH1, AH) 178 mm/7 inch (CCCf Series AH1, AH, AH) 8 inch/0 mm (FM Series AH-00) Maximum K-Factor of Sprinkler to be Connected to Sprinkler Reducing Nipple: Refer to footnotes in the Friction Loss Data section Maximum Number of 90 Bends Per Flexible Hose: Refer to the Friction Loss Data section Flexible Hose Bend Characteristics: NOTE: For out-of-plane (three-dimensional) bends, care shall be taken to avoid imparting torque on the flexible hose. Minimum Bend Radius 90 Minimum Bend Radius X Minimum Bend Radius OR Minimum Bend Radius Minimum Bend Radius X Minimum Bend Radius OR Minimum Bend Radius Minimum Bend Radius Minimum Bend Radius SCAN QR CODE FOR ACCESS TO THE FULL I-VICFLEX.BRG BEND RADIUS GUIDE INSTRUCTIONS ON VICTAULIC.COM INTRODUCTION Victaulic VicFlex Sprinkler Fittings connect the sprinkler piping directly to the sprinkler using a flexible hose and fittings. Each drop assembly comes with one flexible hose, one adapter nipple or captured coupling, one sprinkler reducing nipple, and the Style AB5 Bracket. IMPORTANT INSTALLATION INFORMATION Victaulic VicFlex products shall be installed according to current, applicable National Fire Protection Association (NFPA 1, 1D, 1R, etc.) standards or equivalent standards and in accordance with applicable building and fire codes. Victaulic VicFlex products are intended to be installed in wet, dry, or preaction actuated systems. Deviations from these standards or alterations to Victaulic VicFlex products or sprinklers will void any Victaulic warranty and will impact system integrity. Installations shall meet the provisions of the local authority having jurisdiction and local codes, as applicable, and shall comply with all design specifications. Victaulic VicFlex Sprinkler Fittings and Style AB5 Brackets shall not be intermixed with other manufacturer s flexible sprinkler products. When using recessed sprinklers, the standard long elbow reducer is recommended. Refer to the specific Victaulic product submittal for applications and listing information. In addition, when installing Victaulic FireLock Automatic Sprinklers with Victaulic VicFlex Sprinkler Fittings, refer to the I-0 Installation and Maintenance Instructions for details on sprinkler installation requirements. Submittals and installation instructions can be downloaded at victaulic.com. Size the piping system to provide at least the minimum required flow rate for the sprinkler system. Per NFPA requirements, flush the system to remove foreign material. Continue to flush the system until water runs clear. DO NOT install sprinkler system piping through heating ducts. DO NOT connect sprinkler system piping to domestic hot water systems. DO NOT allow electrical wiring or other cabling to be hung or wrapped around the sprinkler piping system. DO NOT install sprinklers and sprinkler fittings where they will be exposed to temperatures that exceed the maximum ambient temperature rating for the sprinkler and sprinkler fittings. The flexible hose shall not be bent or fluctuated up-and-down or side-to-side when it is pressurized. Flexible hose and fittings have limited flexibility* and are intended only to be installed with bends not less than their respective minimum bend radii. DO NOT install flexible hose in a straight configuration. Protect wet piping systems from freezing temperatures. If construction is altered, the building owner or their representative is responsible for referencing applicable standards to determine if additional sprinklers or other system adjustments are required. The building owner or their representative is responsible for maintaining the fire protection system in proper operating condition. For minimum maintenance and inspection requirements, refer to NFPA 5 and any other applicable NFPA standards that describe the care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that shall be followed. WARNING Relocation of Victaulic VicFlex products SHALL be performed by qualified personnel familiar with the system s original design criteria, sprinkler listings/ approvals, and state and local codes (including NFPA 1 standards). Failure to relocate this Victaulic VicFlex product properly could affect its performance during a fire, resulting in death or serious personal injury and property damage. * Reference UL : Section 5.1 I-VICFLEX.AB5_

FLEXIBLE HOSE ASSEMBLY DRAWINGS Refer to pages 1 0 of this manual for flexible hose technical data. Example Series AH Flexible Hose Shown Below Example Series AH-CC Flexible Hose Shown Below 1 1 5 Item Example Series AH Description Example Series AH-CC Description 1 Flexible Hose Assembly Flexible Hose Assembly Adapter Nipple Coupling Assembly Reducer (Flexible Hose to Sprinkler) Reducer (Flexible Hose to Sprinkler) Shipping Cap Identification Sleeve 5 Identification Sleeve BRACKET ASSEMBLY DRAWING Refer to pages 8 11 of this manual for bracket installation instructions. 5 1 Item Description 1 -inch/610-mm or 8-inch/119-mm Square Bar* Center Gate Assembly with Adjustment Screw Style AB5 End Bracket Wing Screw 5 Relocation Warning Label * Reference submittal document 10.85 for listing information. Square bar length is in reference to nominal ceiling grid spacing. I-VICFLEX.AB5_

1-INCH/DN5 IGS CONNECTION TO THE SPRINKLER PIPING USING A SERIES AH1-CC OR SERIES AH-CC FLEXIBLE HOSE CORRECT - IGS Groove Profile INCORRECT - Orignal Groove System (OGS) Groove Profile Pipe and grooves are not shown to scale The Style 108 Coupling of the Series AH1-CC and AH-CC shall be used ONLY with sprinkler piping connections that are prepared to Victaulic IGS proprietary groove specifications. DO NOT attempt to install the coupling on sprinkler piping connections that are prepared to any other groove specification. Refer to Victaulic publication 5.1 for the IGS groove specification, which can be downloaded at victaulic.com. WARNING The flexible hose shall not be bent or fluctuated up-and-down or side-to-side when it is pressurized for test. Failure to follow this instruction could cause improper sprinkler operation, resulting in death or serious personal injury and property damage. DO NOT REMOVE NUT/BOLT FOR INITIAL INSTALLATION 1. DO NOT DISASSEMBLE THE COUPLING: The Style 108 Coupling of the Series AH1-CC and AH-CC is designed so that the installer does not need to remove the bolt, nut, and linkage for installation. This facilitates installation by allowing the installer to directly insert the sprinkler piping s grooved end into the coupling.. The outside surface of the sprinkler piping, between the groove and the end of the sprinkler piping, shall be smooth and free from indentations, projections, weld seam anomalies, and roll marks to ensure a leak-tight seal. All oil, grease, loose paint, dirt, and cutting particles shall be removed. The sprinkler piping s outside diameter ( OD ), groove dimensions, and maximum allowable flare diameter shall be within the tolerances published in current Victaulic IGS specifications, publication 5.1, which can be downloaded at victaulic.com.. Check the gasket to verify that it is suitable for the intended service. The color code identifies the material grade. Refer to Victaulic publication 05.01 for the color code chart, which can be downloaded at victaulic.com. REFER TO THE NOTICE BELOW FOR IMPORTANT GASKET INFORMATION. a. IF ANY CONDITIONS LISTED IN THE NOTICE ARE MET, APPLY A THIN COAT OF A COMPATIBLE LUBRICANT, SUCH AS VICTAULIC LUBRICANT OR SILICONE LUBRICANT, ONLY TO THE GASKET SEALING LIPS. CAUTION If any conditions listed in the notice are met, a thin coat of a compatible lubricant shall be applied only to the gasket sealing lips to prevent pinching, rolling, or tearing during assembly. Failure to use a compatible lubricant will cause gasket damage, resulting in joint leakage and property damage. NOTICE Series AH1-CC and AH-CC Flexible Hoses are designed for use ONLY in wet, dry, and preaction actuated fire protection systems (temperatures greater than 0 F/ 0 C). Gaskets for Style 108 Coupling assemblies of Series AH1-CC and AH-CC Flexible Hoses are provided with Vic-Plus. Additional lubrication is not required for the initial installation of wet pipe systems that are installed at or continuously operating above 0 F/ 18 C. Refer to Victaulic publication 05.0 for the Vic-Plus Safety Data Sheet (SDS), which can be downloaded at victaulic. com. Supplemental lubrication is required only if any of the following conditions exist. Apply a thin coat of a compatible lubricant to the gasket sealing lips, as noted in step a on this page. It is not necessary to remove the gasket from the housings to apply additional lubricant to the exterior surface. If the installation or continuous operating temperature is below 0 F/ 18 C If the gasket has been exposed to fluids prior to installation If the surface of the gasket does not have a hazy appearance If the gasket is being installed into a dry pipe system If the system will be subjected to air tests prior to being filled with water If the gasket was involved in a previous installation If the gasket sealing surfaces of the pipe contain raised or undercut weld seams, or cracks or voids at the weld seams Lubricated gaskets will not enhance sealing capabilities on adverse pipe conditions. Pipe condition and pipe preparation shall conform to the requirements listed in these product installation instructions. WARNING Never leave a Style 108 Coupling of a Series AH1-CC or AH-CC partially assembled. A partially assembled coupling poses a drop or fall hazard during installation and a burst hazard during testing. Keep hands away from the opening of the coupling when attempting to insert the grooved sprinkler piping into the coupling. Failure to follow these instructions could result in serious personal injury and property damage. I-VICFLEX.AB5_

I-VICFLEX.AB5 / Victaulic VicFlex Sprinkler Fitting / Installation Instructions. Assemble the joint by inserting the grooved end of the sprinkler piping into the opening of the coupling. The grooved sprinkler piping shall be inserted into the coupling until contact with the center leg of the gasket occurs. A visual check is required to verify that the coupling keys align with the groove in the sprinkler piping and engage with the spacer on the inlet end of the flexible hose. WARNING Visual inspection of each joint is required. Improperly assembled joints shall be corrected before the system is tested or placed into service. Any components that exhibit physical damage due to improper assembly shall be replaced. Failure to follow these instructions could cause joint failure, resulting in death or serious personal injury and property damage. WARNING GOOD The nut shall be tightened until metal-to-metal contact occurs at the bolt pads. Failure to follow instructions for tightening hardware could result in: Personal injury or death Bolt damage or fracture Damaged or broken bolt pads or fractures to housings Joint leakage and property damage BAD 6. BAD GOOD OVAL NECK OF BOLT SEATED PROPERLY 5. Visually inspect the bolt pads at each joint to verify that metalto-metal contact is achieved in accordance with step 5. NOTICE Refer to the instructions on page 1 for reassembly requirements. OVAL NECK OF BOLT NOT SEATED PROPERLY Using an impact wrench or standard socket wrench with an 11/16-inch/17-mm deep well socket, tighten the nut until metal-tometal contact occurs at the bolt pads. Verify that the oval neck of the bolt seats properly in the bolt hole. DO NOT continue to tighten the nut after metal-to-metal bolt pad contact is achieved. NOTE: During tightening, support the hose near the Style 108 Coupling to verify that the inlet end of the Series AH1-CC or AH-CC Flexible Hose remains straight and aligned with the coupling. I-VICFLEX.AB5_5

INSTRUCTIONS FOR INITIAL USE OF A VICTAULIC FIRELOCK NO. 101 90 ELBOW OR NO. 10 STRAIGHT TEE INSTALLATION-READY FITTING WITH A SERIES AH1-CC OR AH-CC FLEXIBLE HOSE (1-INCH/DN5 IGS CONNECTION) NOTICE The following procedure applies only to 1-inch/DN5 No. 101 90 Elbows and No. 10 Straight Tees (IGS connection). No. 101 90 Elbows and No. 10 Straight Tees do not ship preassembled to the Series AH1-CC or AH-CC Flexible Hose. The No. 101 or No. 10 does not need to be fully disassembled for initial installation onto the inlet end of the Series AH1-CC or AH-CC Flexible Hose. 1. Loosen the nut of the Style 108 Coupling. Remove the Style 108 Coupling from the end of the Series AH1-CC or AH-CC Flexible Hose. Spacer Inspect Inlet End of Flexible Hose. Inspect the inlet end of the Series AH1-CC or AH-CC Flexible Hose to verify that there is no damage (dents, crushed edges, etc.). A new, Victaulic-supplied Series AH1-CC or AH-CC Flexible Hose shall be used if any damage is present.. Verify that the spacer is oriented on the inlet end of the Series AH1-CC or AH-CC Flexible Hose, as shown to the left.. Loosen and remove the hardware from the side of the No. 101 90 Elbow or No. 10 Straight Tee that is intended to connect with the inlet of the Series AH1-CC or AH-CC Flexible Hose. NO. 101 NO. 10 5. Insert the inlet end of the Series AH1-CC or AH-CC Flexible Hose into the No. 101 90 Elbow or No. 10 Straight Tee. Verify that the gasket is seated fully in the gasket pocket of each housing and that the housings' keys engage with the spacer on the inlet end of the Series AH1-CC or AH-CC Flexible Hose. 5a. Reinstall the two bolts and nuts that were removed in step. NOTE: Verify that the oval neck of each bolt seats properly in the bolt holes. DO NOT tighten the nuts completely. The bolt pads need to be set at a gap for installation of the fitting. The nuts should be flush with the top of each bolt to provide the proper gap. Use caution when handling the fitting/hose assembly (the fitting may not be secured completely to the inlet end of the Series AH1-CC or AH-CC Flexible Hose). 6. Follow the steps in the I-101/10 or I-10/10 installation instructions for the required tightening sequence. NOTE: During tightening, verify that the inlet end of the Series AH1-CC or AH-CC Flexible Hose remains straight and aligned with the opening of the No. 101 90 Elbow or No. 10 Straight Tee. The I-101/10 or I-10/10 can be accessed and downloaded by scanning the applicable QR code below. In addition, these instructions contain important reassembly instructions and shall be referenced any time a No. 101 90 Elbow or No. 10 Straight Tee is removed from the sprinkler piping and reused. SCAN QR CODE FOR ACCESS TO THE FULL I-101/10 INSTALLATION INSTRUCTIONS ON VICTAULIC.COM SCAN QR CODE FOR ACCESS TO THE FULL I-10/10 INSTALLATION INSTRUCTIONS ON VICTAULIC.COM I-VICFLEX.AB5_6

CONNECTION TO THE SPRINKLER PIPING USING AN ADAPTER NIPPLE AND A SERIES AH1, AH1-LP, AH, AH-LP, AH, AH-LP, AH-00, OR AH-68 FLEXIBLE HOSE WARNING The flexible hose shall not be bent or fluctuated up-and-down or side-to-side when it is pressurized for test. Failure to follow this instruction could cause improper sprinkler operation, resulting in death or serious personal injury and property damage. INSTALLATION OF THE SPRINKLER REDUCING NIPPLE ONTO THE FLEXIBLE HOSE TURN CONNECTION NUT ONLY 1. Apply pipe joint compound or PTFE thread sealant tape to the tapered threads of the adapter nipple, in accordance with the pipe joint compound or tape manufacturer s instructions. Using a pipe wrench, tighten the adapter nipple into the sprinkler piping. 1. Confirm that the seal inside the nut of the flexible hose is in place and is free from damage prior to installation. Connect the nut to the sprinkler reducing nipple. SHORT 90 ELBOW REDUCERS ARE TYPICALLY USED WITH CONCEALED SPRINKLERS. DO NOT use pipe joint compound or PTFE thread sealant tape on the fine threads of the sprinkler reducing nipple. The seal inside the nut of the flexible hose provides the leak-proof connection. Tighten the connection nut to a torque of 0 ft-lbs/5 N m (approximately 1/ to / of a turn past hand-tight). NOTE: To prevent damage to the seal, tighten the assembly by applying torque only to the connection nut and DO NOT exceed the specified torque.. Confirm that the seal inside the nut of the flexible hose is in place and is free from damage prior to installation. Connect the nut to the adapter nipple, as shown above. DO NOT use pipe joint compound or PTFE thread sealant tape on the threads of the adapter nipple. The seal inside the nut of the flexible hose provides the leak-proof connection. Tighten the connection nut to a torque of 0 ft-lbs/5 N m (approximately 1/ to / of a turn past hand-tight). NOTE: To prevent damage to the seal, tighten the assembly by applying torque only to the connection nut and DO NOT exceed the specified torque. I-VICFLEX.AB5_7

INSTALLATION FOR WOOD JOISTS/STUDS 1. Install the flexible hose into the sprinkler piping and the sprinkler reducing nipple onto the flexible hose by following the applicable instructions on pages 7.. Place an end bracket assembly onto each end of the square bar so that the wing screw is facing outward (away from the center gate assembly), as shown above.. Install the Style AB5 Bracket to the wood joists/studs by using one, 1 1/-inch/-mm long #10 wood screw in each end bracket location shown in the photo above. Verify that the top of the 90 bend remains flush with the top of the wood joist/stud during installation of the wood screw.. Place the end bracket assembly up against the inside surface of the one wood joist/stud with the top of the 90 bend resting on top of the wood joist/stud, as shown above. Repeat this step for the other end bracket assembly. 5. Secure the end brackets to the square bar by tightening the wing screw on top of each end bracket assembly until the bottom of the wing screw reaches metal-to-metal contact with the top of the end bracket. 6. Follow all steps in the Sprinkler Reducing Nipple Installation and Sprinkler Installation sections on page 11. I-VICFLEX.AB5_8

INSTALLATION FOR CD PROFILE ( MM) CHANNEL CEILING SYSTEMS (FM AND VdS ONLY) 1. Install the flexible hose into the sprinkler piping and the sprinkler reducing nipple onto the flexible hose by following the applicable instructions on pages 7.. Place an end bracket assembly onto each end of the square bar so that the wing screw is facing inward (toward the center gate assembly), as shown above.. Tighten the wing screw on the top of each end bracket to a torque of 15 inch-lbs/1.7 N m (approximately hand-tight, plus 1/ of a turn). 5. Follow all steps in the Sprinkler Reducing Nipple Installation and Sprinkler Installation sections on page 11.. Install each end bracket of the Style AB5 Bracket into the rails of the CD Profile ( mm) Channel Ceiling System. Verify that the lip of each end bracket assembly engages with the channel. I-VICFLEX.AB5_9

INSTALLATION FOR ASTM C65 METAL JOISTS/ STUDS INSTALLED IN ACCORDANCE WITH ASTM C75 STANDARDS 1. Install the flexible hose into the sprinkler piping and the sprinkler reducing nipple onto the flexible hose by following the applicable instructions on pages 7.. Place an end bracket assembly onto each end of the square bar so that one of the wing screws is facing inward (toward the center gate assembly) and the other wing screw is facing outward (away from the center gate assembly), as shown above.. Tighten the wing screw on the top of each end bracket to a torque of 15 inch-lbs/1.7 N m (approximately hand-tight, plus 1/ of a turn). 5. Follow all steps in the Sprinkler Reducing Nipple Installation and Sprinkler Installation sections on page 11.. Install each end bracket of the Style AB5 Bracket onto the lip of the metal joist/studs. Verify that the lip of each end bracket assembly engages with the lip of the metal joist/stud. I-VICFLEX.AB5_10

SPRINKLER REDUCING NIPPLE INSTALLATION Adjustment Screw 1. Move the center gate assembly of the Style AB5 Bracket to the desired location. Using a # square recessed drive bit, loosen the adjustment screw, then push open the center gate assembly. Slide the sprinkler reducing nipple into the center gate assembly. NOTE: The adjustment screw of the center gate assembly is staked to resist removal.. Close the gate around the sprinkler reducing nipple. The gate will snap together tightly around the sprinkler reducing nipple. Using a # square recessed drive bit, tighten the adjustment screw to a torque of 75 inch-lbs/8.5 N m (until adjustment screw makes metal-to-metal contact with bottom of gate). NOTE: The sprinkler reducing nipple can be adjusted after the drywall is installed by using the adjustment screw on the center gate assembly. SPRINKLER INSTALLATION: Install the sprinkler by following the manufacturer s installation instructions. For Victaulic sprinklers, refer to the I-0 Victaulic FireLock Automatic Sprinklers Installation and Maintenance Instructions. For center-of tile installations, position the center gate assembly between the two reference marks on the square bar, as shown above. I-VICFLEX.AB5_11

INSTRUCTIONS FOR REASSEMBLY OF A SERIES AH1-CC, AH1-CC-LP, AH-CC, OR AH-CC-LP FLEXIBLE HOSE WARNING Verify that the system is depressurized and drained completely before attempting to disassemble a Series AH1-CC, AH1-CC-LP, AH-CC, or AH-CC-LP Flexible Hose from the sprinkler piping. Failure to follow this instruction could result in death or serious personal injury and property damage. 1. Verify that the system is depressurized and drained completely before attempting to disassemble a Series AH1-CC, AH1-CC-LP, AH-CC, or AH-CC-LP Flexible Hose from the sprinkler piping.. Loosen the nut of the Style 108 Coupling assembly to permit removal from the sprinkler piping.. Remove the nut, bolt, gasket, and linkage from the Style 108 Coupling housings. Inspect all components for damage or wear. If any damage or wear is present, replace with new Victaulicsupplied components. NOTE: Replacement gaskets shall be of the same grade that is suitable for the intended service.. Verify that the outside surface of the sprinkler piping, between the groove and the end of the sprinkler piping, is smooth and free from indentations, projections, weld seams, and roll marks to ensure a leak-tight seal. All oil, grease, loose paint, dirt, and cutting particles shall be removed. The sprinkler piping s outside diameter ( OD ), groove dimensions, and maximum allowable flare diameter shall be within the tolerances published in current Victaulic IGS specifications, publication 5.1, which can be downloaded at victaulic.com. 7. REASSEMBLE COUPLING ONTO FLEXIBLE HOSE: Place the lubricated gasket onto the inlet end of the flexible hose, then place the Style 108 Coupling housings over the gasket. Verify that the gasket is seated in the gasket pocket of the housings and that the housings' keys engage with the spacer. 8. INSTALL LINKAGE: Install the linkage onto the housings, as shown above. Spacer 5. Verify that the spacer is oriented on the inlet end of the flexible hose, as shown above. CAUTION A thin coat of Victaulic Lubricant or silicone lubricant shall be used to prevent the gasket from pinching/tearing during reassembly. Failure to use a compatible lubricant will cause gasket damage, resulting in joint leakage and property damage. 9. INSTALL HARDWARE: Install the bolt through the housings. Thread the nut onto the bolt until the top of the nut is flush with the end of the bolt, as shown above. Verify that the gasket remains seated in the gasket pocket of the housings and that the housings' keys engage with the spacer. 10. Follow all steps on pages 5 of this instruction sheet to complete the assembly. 6. LUBRICATE GASKET: Apply a thin coat of Victaulic Lubricant or silicone lubricant to the gasket sealing lips and exterior. It is normal for the gasket surface to have a hazy white appearance after it has been in service. I-VICFLEX.AB5_1

TECHNICAL DATA FOR FLEXIBLE HOSES The following section provides friction loss information for flexible hoses that can be used with Style AB5 Brackets. WARNING It is the system designer s responsibility to verify suitability of stainless steel flexible hose for use with the intended fluid media within the piping system and external environment. The material specifier shall evaluate the effect of chemical composition, ph level, operating temperature, chloride level, oxygen level, and flow rate on stainless steel components to confirm system life will be acceptable for the intended service. Failure to follow these instructions could cause product failure, resulting in death or serious personal injury and property damage. I-VICFLEX.AB5_1

SERIES AH1 AND AH1-CC FLEXIBLE HOSE FRICTION LOSS DATA (FM AND UL) AH1-1 AH1-CC-1 AH1-6 AH1-CC-6 AH1-8 AH1-CC-8 AH1- AH1-CC- AH1-7 AH1-CC-7 inches/mm 1 6 8 10 155 7 180 Outlet Size# Equivalent Length of 1-inch/DN5 Schedule 0 Pipe feet/meters Maximum Number of 90 Bends inches/metric FM* UL FM UL 1/ 5.8 5.0 DN15 16. 15.9 /. 55.0 DN0 1.5 16.8 1/ 6.7 6.0 DN15 19. 19. / 55.5 66.0 DN0 16.9 0.1 1/ 87.9 78.0 DN15 6.8.8 / 8.0 80.0 DN0 5.. 1/ 11. 88.0 DN15.1 6.8 / 110. 90.0 DN0.6 7. 1/ 16.5 11.0 DN15 1.6.1 / 17.9 118.0 DN0.0 6.0 5 * 7-inch/178-mm minimum bend radius (tested with standard 5 /-inch/16-mm length straight reducer) -inch/76-mm minimum bend radius (tested and UL Listed only with standard 5 /-inch/16-mm length straight reducer) # /-inch/dn0 outlet data shown with K1.0 - For other K-factor friction loss data, refer to Victaulic submittal 10.95 For the UL Listing, when the 8-inch/10-mm length bracket is used with the Series AH1 or AH1-CC Flexible Hose, the maximum sprinkler K-factor is K8.0 and the maximum spacing is 0 inches/76 mm A higher number of bends may be permitted, provided the sum of degrees is equal to or less than the total maximum allowable degrees of bends (e.g. Two 90 bends equal 180. Three 90 bends equal 70 ). The minimum bend radius and maximum number of 90 offset (bends), stated in these installation instructions, refer to the final installed condition of the hose. For friction loss data for elbows, refer to Victaulic submittal 10.95. NOTE: Differences in equivalent lengths are due to varying test methods, per UL and FM 167 standards. Refer to these standards for additional information regarding friction loss test methods. When using a No. 101 90 Elbow or a No. 10 Straight Tee in place of a Style 108 Coupling on the end of a Series AH1-CC Flexible Hose, the friction loss data shown above shall be added to the No. 101 or No. 10 friction loss data published in Victaulic submittal 10.5. SERIES AH1-LP AND AH1-CC-LP FLEXIBLE HOSE FRICTION LOSS DATA (FM) AH1-1-LP AH1-CC-1-LP AH1-6-LP AH1-CC-6-LP AH1-8-LP AH1-CC-8-LP AH1--LP AH1-CC--LP AH1-7-LP AH1-CC-7-LP inches/mm 1 6 8 10 155 7 180 Outlet Size# inches/metric Equivalent Length of 1-inch/DN5 Schedule 0 Pipe feet/meters* 1/ 9.0 DN15 1.9 / 7.9 DN0 1.6 1/ 58.5 DN15 17.8 / 58.0 DN0 17.7 1/ 81.5 DN15.8 / 8. DN0 5.1 1/ 10. DN15 1.8 / 106. DN0. 1/ 17. DN15 8.8 / 10.8 DN0 9.9 Maximum Number of 90 Bends * 7-inch/178-mm minimum bend radius # /-inch/dn0 outlet data shown with K1.0 - For other K-factor friction loss data, refer to Victaulic submittal 10.95 A higher number of bends may be permitted, provided the sum of degrees is equal to or less than the total maximum allowable degrees of bends (e.g. Two 90 bends equal 180. Three 90 bends equal 70 ). The minimum bend radius and maximum number of 90 offset (bends), stated in these installation instructions, refer to the final installed condition of the hose. NOTE: Differences in equivalent lengths are due to varying test methods, per the FM 167 standard. Refer to this standard for additional information regarding friction loss test methods. I-VICFLEX.AB5_1

SERIES AH AND AH-CC FLEXIBLE HOSE FRICTION LOSS DATA (FM AND UL) AH-1 AH-CC-1 AH-6 AH-CC-6 AH-8 AH-CC-8 AH- AH-CC- AH-7 AH-CC-7 inches/mm 1 6 8 10 155 7 180 Outlet Size# Equivalent Length of 1-inch/DN5 Schedule 0 Pipe feet/meters Maximum Number of 90 Bends inches/metric FM* UL FM UL 1/ 1.8 16.0 DN15..9 / 1.9 17.0 DN0.5 5. 1/ 16.6 1.0 DN15 5.1 6. / 19..0 DN0 5.9 7.0 1/..0 DN15 7.1 9.8 / 0. 7.0 DN0 9. 11. 1/ 0. 6.0 DN15 9. 1.0 /.9 6.0 DN0 10. 1.0 1/ 7.0 55.0 DN15 11. 16.8 / 7.5 5.0 DN0 11. 16. 5 8 10 1 * 7-inch/178-mm minimum bend radius (tested with standard 5 /-inch/16-mm length straight reducer) -inch/50-mm minimum bend radius (tested and UL Listed only with standard 5 /-inch/16-mm length straight reducer) # /-inch/dn0 outlet data shown with K1.0 - For other K-factor friction loss data, refer to Victaulic submittal 10.85 For the UL Listing, when the 8-inch/10-mm length bracket is used with the Series AH or AH-CC Flexible Hose, the maximum sprinkler K-factor is K8.0 and the maximum spacing is 0 inches/76 mm A higher number of bends may be permitted, provided the sum of degrees is equal to or less than the total maximum allowable degrees of bends (e.g. Two 90 bends equal 180. Three 90 bends equal 70 ). The minimum bend radius and maximum number of 90 offset (bends), stated in these installation instructions, refer to the final installed condition of the hose. For friction loss data for elbows, refer to Victaulic submittal 10.85. NOTE: Differences in equivalent lengths are due to varying test methods, per UL and FM 167 standards. Refer to these standards for additional information regarding friction loss test methods. When using a No. 101 90 Elbow or a No. 10 Straight Tee in place of a Style 108 Coupling on the end of a Series AH-CC Flexible Hose, the friction loss data shown above shall be added to the No. 101 or No. 10 friction loss data published in Victaulic submittal 10.5. SERIES AH-LP AND AH-CC-LP FLEXIBLE HOSE FRICTION LOSS DATA (FM) AH-1-LP AH-CC-1-LP AH-6-LP AH-CC-6-LP AH-8-LP AH-CC-8-LP AH--LP AH-CC--LP AH-7-LP AH-CC-7-LP inches/mm 1 6 8 10 155 7 180 Outlet Size# inches/metric Equivalent Length of 1-inch/DN5 Schedule 0 Pipe feet/meters* 1/ 1.7 DN15. / 1.5 DN0.1 1/ 17.0 DN15 5. / 16.8 DN0 5.1 1/ 5.0 DN15 7.6 /.7 DN0 7.5 1/.0 DN15 10.1 /.7 DN0 10.0 1/ 1.1 DN15 1.5 / 0.7 DN0 1. Maximum Number of 90 Bends * 7-inch/178-mm minimum bend radius # /-inch/dn0 outlet data shown with K1.0 - For other K-factor friction loss data, refer to Victaulic submittal 10.85 A higher number of bends may be permitted, provided the sum of degrees is equal to or less than the total maximum allowable degrees of bends (e.g. Two 90 bends equal 180. Three 90 bends equal 70 ). The minimum bend radius and maximum number of 90 offset (bends), stated in these installation instructions, refer to the final installed condition of the hose. NOTE: Differences in equivalent lengths are due to varying test methods, per the FM 167 standard. Refer to this standard for additional information regarding friction loss test methods. I-VICFLEX.AB5_15

SERIES AH-00 FLEXIBLE HOSE FRICTION LOSS DATA (FM) AH-00-1 AH-00-6 AH-00-8 AH-00- AH-00-7 inches/mm 1 6 8 10 155 7 180 Outlet Size# inches/metric Equivalent Length of 1-inch/DN5 Schedule 0 Pipe feet/meters* 1/.5 DN15 7. / 1.9 DN0.5 1/ 7.8 DN15 8.5 / 19. DN0 5.9 1/ 8. DN15 11.6 / 0. DN0 9. 1/. DN15 1.9 /.9 DN0 10. 1/ 6.6 DN15 1. / 7.5 DN0 11. Maximum Number of 90 Bends * 8-inch/0-mm minimum bend radius (tested with standard 5 /-inch/16-mm length straight reducer) # /-inch outlet data shown with K1.0 - For other K-factor friction loss data, refer to Victaulic submittal 10.8 A higher number of bends may be permitted, provided the sum of degrees is equal to or less than the total maximum allowable degrees of bends (e.g. Two 90 bends equal 180. Three 90 bends equal 70 ). The minimum bend radius and maximum number of 90 offset (bends), stated in these installation instructions, refer to the final installed condition of the hose. For friction loss data for elbows, refer to Victaulic submittal 10.8. NOTE: Differences in equivalent lengths are due to varying test methods, per the FM 167 standard. Refer to this standard for additional information regarding friction loss test methods. SERIES AH-68 FLEXIBLE HOSE FRICTION LOSS DATA (FM) AH-68 inches/mm 8 711 Outlet Size# inches/metric Equivalent Length of 1-inch/DN5 Schedule 0 Pipe feet/meters* 1/. DN15 6.8 / 1.1 DN0.9 Maximum Number of 90 Bends * 7-inch/178-mm minimum bend radius (tested with standard 5 /-inch/16-mm length straight reducer) # /-inch outlet data shown with K1.0 - For other K-factor friction loss data, refer to Victaulic submittal 10.85 For friction loss data for elbows, refer to Victaulic submittal 10.85. NOTE: Differences in equivalent lengths are due to varying test methods, per the FM 167 standard. Refer to this standard for additional information regarding friction los test methods. SERIES AH AND AH-LP FLEXIBLE HOSE FRICTION LOSS DATA (FM) REGIONAL AVAILABILITY ONLY AH-1 AH-1-LP AH-6 AH-6-LP AH-8 AH-8-LP AH- AH--LP AH-7 AH-7-LP inches/mm 1 6 8 10 155 7 180 Outlet Size# Equivalent Length of 1-inch/DN5 Schedule 0 Pipe feet/meters* inches/metric Series AH Series AH-LP 1/.8 5.8 DN15 10. 16. /. 69.8 DN0 10. 1. 1/.0.0 DN15 1.1 18. /.1 76.5 DN0 1.. 1/ 65. 75.0 DN15 19.9.8 / 67.8 9.5 DN0 0.7 8.1 1/ 87. 90.0 DN15 6.6 7. / 91.6 108.6 DN0 7.9.1 1/ 109.7 105. DN15..0 / 115.5 1.9 DN0 5. 8.0 1 Maximum Number of 90 Bends * 7-inch/178-mm minimum bend radius (tested with standard 5 /-inch/16-mm length straight reducer) # For the Series AH Flexible Hose, the /-inch/dn0 outlet data is shown with K1.0. For the Series AH-LP Flexible Hose, the /-inch/dn0 outlet data is shown with K11.. For other K-factor friction loss data, refer to Victaulic submittal 10.9. A higher number of bends may be permitted, provided the sum of degrees is equal to or less than the total maximum allowable degrees of bends (e.g. Two 90 bends equal 180. Three 90 bends equal 70 ). The minimum bend radius and maximum number of 90 offset (bends), stated in these installation instructions, refer to the final installed condition of the hose. For friction loss data for elbows, refer to Victaulic submittal 10.9. I-VICFLEX.AB5_16

SERIES AH FLEXIBLE HOSE FRICTION LOSS DATA (FM) REGIONAL AVAILABILITY ONLY AH-1 AH-6 AH-8 AH- AH-7 inches/mm 1 6 8 10 155 7 180 Outlet Size# inches/metric Equivalent Length of 1-inch/DN5 Schedule 0 Pipe feet/meters* 1/ 0.6 DN15 6. / 16. DN0 5.0 1/ 9.7 DN15 9.0 / 1.8 DN0 6.7 1/ 7.5 DN15 8. / 8. DN0 8.6 1/ 5.7 DN15 10.9 /.9 DN0 10.6 1/ 5.9 DN15 1.0 / 1.5 DN0 1.6 Maximum Number of 90 Bends * 7-inch/178-mm minimum bend radius (tested with standard 5 /-inch/16-mm length straight reducer) # /-inch/dn0 outlet data shown with K1.0 - For other K-factor friction loss data, refer to Victaulic submittal 10.8 A higher number of bends may be permitted, provided the sum of degrees is equal to or less than the total maximum allowable degrees of bends (e.g. Two 90 bends equal 180. Three 90 bends equal 70 ). The minimum bend radius and maximum number of 90 offset (bends), stated in these installation instructions, refer to the final installed condition of the hose. For friction loss data for elbows, refer to Victaulic submittal 10.8. NOTE: Differences in equivalent lengths are due to varying test methods, per the FM 167 standard. Refer to this standard for additional information regarding friction loss test methods. Series AH Flexible Hose Assembly Number Correlation Series AH Hose Assembly Designation AH-1 AH-6 AH-8 AH- AH-7 Outlet Size Series AQB Hose Assembly Designation Series AFB Hose Assembly Designation 1/ AQB1HLD AFB1HLD / AQB1TLD AFB1TLD 1/ AQB6HLD AFB6HLD / AQB6TLD AFB6TLD 1/ AQB8HLD AFB8HLD / AQB8TLD AFB8TLD 1/ AQBHLD AFBHLD / AQBTLD AFBTLD 1/ AQB7HLD AFB7HLD / AQB7TLD AFB7TLD SERIES AH-LP FLEXIBLE HOSE FRICTION LOSS DATA (FM) REGIONAL AVAILABILITY ONLY AH-1-LP AH-6-LP AH-8-LP AH--LP AH-7-LP inches/mm 1 6 8 10 155 7 180 Outlet Size# inches/metric Equivalent Length of 1-inch/DN5 Schedule 0 Pipe feet/meters* 1/ 1.7 DN15 6.6 / 19.9 DN0 6.1 1/ 9.8 DN15 9.0 /. DN0 7. 1/ 9. DN15 8.9 / 9.9 DN0 9.1 1/ 7. DN15 11. / 0. DN0 9. 1/ 7.5 DN15 1.5 / 8.6 DN0 11.7 Maximum Number of 90 Bends * 7-inch/178-mm minimum bend radius (tested with standard 5 /-inch/16-mm length straight reducer) # The /-inch/dn0 outlet data is shown with K1.0. For other K-factor friction loss data, refer to Victaulic submittal 10.8. A higher number of bends may be permitted, provided the sum of degrees is equal to or less than the total maximum allowable degrees of bends (e.g. Two 90 bends equal 180. Three 90 bends equal 70 ). The minimum bend radius and maximum number of 90 offset (bends), stated in these installation instructions, refer to the final installed condition of the hose. For friction loss data for elbows, refer to Victaulic submittal 10.8. I-VICFLEX.AB5_17

SERIES AH1, AH1-CC, AH, AH-CC, AND AH* FLEXIBLE HOSE FRICTION LOSS DATA (VDS) Length of Flexible Hose mm/inches 1 Outlet Size Metric/inches DN15/1/ DN0// Maximum Number of 90 Bends at 76.-mm/-inch Bend Radius Series AH1 and AH1-CC Series AH and AH-CC Series AH* Equivalent Length of Steel Pipe in meters/feet According to EN 1055 DN 0 (6,9 x,65).0 1.9 Equivalent Length of Steel Pipe in meters/feet According to EN 1055 DN 5 (,7 x,5) 5.5 18.0 Equivalent Length of Steel Pipe in meters/feet According to EN 1055 DN 0 (6,9 x,65) 5.9 19. 6 DN15/1/ DN0//.6 15.0 6. 1.0 6.9.5 10 8 DN15/1/ DN0// 6.1 0.0 8.5 7.9 9. 0.0 155 DN15/1/ DN0// 7.6 5.0 10.7 5.1 11. 7.5 180 7 DN15/1/ DN0// 9. 0.0 1.8.0 1.7 5.0 * SERIES AH REGIONAL AVAILABILITY ONLY Series AH1, AH1-CC, AH, AH-CC, and AH Flexible Hoses are VdS Approved for use in wet systems only. Only VdS Approved pendent spray sprinklers of 10-mm, 15-mm, and 0-mm nominal diameters with K-factors of 57, 80, and 115 shall be used. Tested with a 5 /-inch/16-mm length straight reducer. The VdS Approval applies only for use with the following manufacturers suspended ceiling systems: CD Profile ( mm) Channel Ceiling Systems for Style AB5 Brackets Hilti Lindner Knauf Rigips Lafarge Other manufacturers ceiling systems, with comparable or better performance, can be considered for approval. VdS standards for safety include, but are not limited to: pressure cycling, corrosion resistance, flow characteristics, vibration resistance, leakage, mechanical strength, and hydrostatic strength. Differences in equivalent lengths are due to varying test methods, per FM 167 and VdS standards. Refer to these standards for additional information regarding friction loss test methods. SERIES AH1, AH1-CC, AH, AND AH-CC FLEXIBLE HOSE FRICTION LOSS DATA (LPCB) Length of Flexible Hose mm/inches 1 Outlet Size Metric/inches DN15/1/ DN0// Maximum Number of 90 Bends at 76.-mm/-inch Bend Radius Series AH1 and AH1-CC* Equivalent Length of Steel Pipe in meters/feet According to EN 1055 DN 5 (,7 x,5) 1.6.6 Series AH and AH-CC** Equivalent Length of Steel Pipe in meters/feet According to EN 1055 DN 5 (,7 x,5) 1.8 6.0 6 DN15/1/ DN0// 16.9 55..6 11.9 10 8 DN15/1/ DN0// 19.9 65.1. 1.0 155 DN15/1/ DN0//.5 80..1 1.6 180 7 DN15/1/ DN0// 8.5 9. 5.5 18.1 * Hose Type and Size: DN0/0.8-inch Nominal ID, per LPS 161 ** Hose Type and Size: DN5/1-inch Nominal ID, per LPS 161 Series AH1 (10l/0l), Series AH (10l/0), Series AH1-CC (10l/0), and Series AH-CC (10l/0) Flexible Hoses are LPCB Approved for use in wet systems only. Only LPCB Approved pendent spray sprinklers of 10-mm, 15-mm, and 0-mm nominal diameters with K-factors of 57 and 80 shall be used. Tested with a 5 /-inch/16-mm length straight reducer. When using a No. 101 90 Elbow or a No. 10 Straight Tee in place of a Style 108 Coupling on the end of a Series AH1-CC or AH-CC Flexible Hose, the friction loss data shown above shall be added to the No. 101 or No. 10 friction loss data published in Victaulic submittal 10.5. I-VICFLEX.AB5_18

SERIES AH1 FLEXIBLE HOSE FRICTION LOSS DATA (CCCf) AH1-1 AH1-6 AH1-8 AH1- AH1-7 mm/inches 1 6 110 8 155 180 7 Equivalent Length meters/feet Straight Configuration Bend Configuration.78 5.80 15.7 19.0 5.59 10.15 18.. 9.75 16.5.0 5. 1.15.9 9.9 75. 1.6 5.98 6.8 85. 178-mm/7-inch minimum bend radius Friction loss data is in accordance with GB515.16. Corresponding flow rate is 11.55 liters per minute/0 gallons per minute. SERIES AH FLEXIBLE HOSE FRICTION LOSS DATA (CCCf) AH-1 AH-6 AH-8 AH- AH-7 178-mm/7-inch minimum bend radius mm/inches 1 6 110 8 155 180 7 Equivalent Length meters/feet Straight Configuration Bend Configuration 0.87.70.9 8.9 1.00.80. 9...66 7. 15..90 6.50 9.5 1..1 7.16 10.9.5 SERIES AH FLEXIBLE HOSE FRICTION LOSS DATA (CCCf) REGIONAL AVAILABILITY ONLY AH-1 AH-6 AH-8 AH- AH-7 178-mm/7-inch minimum bend radius mm/inches 1 6 110 8 155 180 7 Equivalent Length meters/feet Straight Configuration Bend Configuration 5.19 7.91 17.0 6.0 6.17 9.9 0..6 8.9 1.55 9. 7.7 11.10 0.0 6. 65.7 1..6.1 77.6 I-VICFLEX.AB5_19

INSTALLATION INSTRUCTIONS I-VICFLEX.AB5 Victaulic VicFlex Style AB5 Sprinkler Fitting for Wood or Metal Joists/Studs and CD Profile ( mm) Channel Ceiling Systems For complete contact information, visit victaulic.com I-VICFLEX.AB5 99 REV E UPDATED 10/018 Z000AB5000 VICTAULIC AND VICFLEX ARE REGISTERED TRADEMARKS OR TRADEMARKS OF VICTAULIC COMPANY AND/OR ITS AFFILIATED ENTITIES IN THE UNITED STATES AND/OR OTHER COUNTRIES. 018 VICTAULIC COMPANY. ALL RIGHTS RESERVED.