Emotron DCM Control Unit

Similar documents
Drainage control the easy way. Emotron DCM control unit

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

KD LV Motor Protection Relay

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

LK Position Switches TECHNICAL DATASHEET.

Bulletin 825 SMM Smart Motor Manager

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

HGM501 Gen-set Controller USER MANUAL. Smartgen Technology

onlinecomponents.com Compact Coded Magnetic Safety Interlock Switch and Control Unit

DEEP SEA ELECTRONICS PLC

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

Application Engineering Europe

FL series position switches

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

Synergy EN product information

Three-Phase Soft Starters

Safety rope switch without reset for simple stop

ENGINE PROTECTION BOARD PDM1

Safety rope switches with reset for emergency stop

MU MMMREV.2 09/01 UNI EN ISO ELECTRONIC POWER FACTOR REGULATOR type QR INSTRUCTION MANUAL PAG. 7

DKG-114 MANUAL AND REMOTE START UNIT

Solid State Relays, 3-phase

AccuPower AQU126B Installation Instructions

Minimum 27 in-lb torque

RT2DB Excitation and voltage regulation system for synchronous generators

DEEP SEA ELECTRONICS PLC

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

1 Phase electronic contactor (SC 1)

Start-up instructions

Thermal Overload Relays

Switches with manual reset

ECONOMISER SERIES E2T USER MANUAL

Manual motor starter magnetic only MO325

VEO. V2TF01 Art.Nr.: V2TF01P Art.Nr.: TECHNICAL DATA

825-P Modular Protection System for motors Specification Guide

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

Thermal overload relay TF65 and TF96

DEEP SEA ELECTRONICS PLC

CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS

SED2. Variable Frequency Drives. with Conventional Bypass Options. Variable Frequency Drives. Description. Features F-9.

ENGLISH NO Fan Starter INSTRUCTION MANUAL. Fan Starter 4. 4 kw 400 V 3~(+N) 50 Hz ART. NO

702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS

Electronic overload relays EF205 and EF370

Safety rope switch with reset for emergency stop

DRB-1 Series Instruction Manual

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

DRL-1 Series Instruction Manual

REVISION HISTORY REVISION HISTORY

PRODUCTS: POWER SUPPLY

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Thermal overload relay TF140DU and TF140DU-V1000

AccuPower AQU128B Installation Instructions

MODEL 422 Submersible Pump Controller

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Single & Three-Phase Soft Starters

Minimum 27 in-lb Torque

RVS-DN Digital Reduced Voltage Motor Starter

Application Engineering

MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGER. MicroMax. Article no. F IBC control Made in Sweden

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

Safety switches for hinges

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

Submittal Data Information

Scheda prodotto Relè Series B

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Solid State Relays contactor with Integrated Fuse Type RGC1F

Temperature Controllers

Electronic Braking Systems

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

IBC control. MicroMax MANUAL. With adjustable boost function and threshold value. Since Set of EMC-glands as an option

PSBSH 2012B. PSBSH 13,8V/2A/7Ah/HERMETIC

DIN EN UL 508 / CSA 3RF A A 0 2

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Electronic overload relay EF65, EF96 and EF146

ALC-PRM-VFC. Ceiling Mounted Photocell. Product Guide. Overview. Features

PSE The efficient range Description

Flight Systems. Replacement for KASSEC DESCRIPTION

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Power Electronics. POWERSWITCH Semiconductor Relay / - Contactor With Load Circuit Monitoring PH 9270

Phone: Fax: Web:

Safety Control HR1S-AC. Safety Relay HR1S-AC

E s h o r t c ir c u it Wit h s t AND r At ing s f o r r -s er ies s u ppl ement Ar y pr o t ec t o r

15 Watt Low-Profile Wall Plug-In, Single Output, 5-24 VDC Switching Power Supply: N.A., Universal Input, ITE, Class II, Energy Star

Designed for ease of integration with automation systems

USERS MANUAL MCD REMOTE OPERATOR

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

Safety switches for hinged doors

DEEP SEA ELECTRONICS PLC

C E R T I F I C A T E O F C O M P L I A N C E

Safety Limit Switch

MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGERS. MicroStart. IBC control

CA Z-EN Overload relays, CT-operated overload relays

Transcription:

Emotron DCM Control Unit Data sheet English

9 2 3 4 5 6 7 8 The Emotron DCM is a control unit that remotely controls submersible pump equipment. Level sensors are not needed to initiate start and stop. The pump stops automatically when it begins to snore (draw air), when the pit has been pumped free from water. During a pumping operation, the Emotron DCM measures the length of the run period and uses this to determine the length of the rest period. The longer the run period, the shorter the rest period. As a result the run and the rest periods are continuously adapted to the rate of flow. Two Emotron DCM can be connected in parallel to control two submersible pumps and allow independent operation and display of monitored values. The dual-pump DCM system must not be installed in a pit of extremely small diameter or width. This will result from time to time in the DCMs failing to detect the stop/minimum level. *)Terminal covers optional. Fig. Emotron DCM and current transformer (CT), both for mounting on standard DIN rail 35mm. L L2 L3 N Exceeding 00 Amps Number of primary and secondary windings see Table 2 L CTM 00 Max. 0 A S S Standard transformer Autoset Max 240VAC A Up to 00 Amp Reset Alarm Number of primary windings see Table L High level Stop K K CTM xxx F Alternative connection S S2 Dig SGND Temp Alarm C Pump DCM L L2 L3 3 F U V W Thermistor PTC - M A Selection, see manual: Digital input connection Dig and SGND, term. 3 and 4. Thermocontact Fig. 2 Connection examplee NOTE: Make sure that the DCM voltage range e.g. 3x380-500 VAC matches the connected pump motor/line voltage, e.g. 3x 400 V. Emotron AB 0-470-0r0

Table Motor and Current transformer less than 00 A Rated motor current Choice of current transformer and number of windings for different pump motor sizes. In order to ensure an accurate calibration of the DCM, it is essential that you use the correct CTM and apply the exact number of windings in accordance with the tables. CTM00 CTM025 CTM050 CTM000 0.4 to.0 A 0.0 to 2.00 A 5 2.0 to 3.0 A 3 3. to 5.0 A 2 5. to 0 A 0. to 2.5 A 2 4 2.6 to 25 A 2 26 to 50 A 5 to 00 A Table 2 Current transformer greater than 00 A Rated motor current Current transformers Number of windings 0 to 50 A 50:5 CTM00 2 5 to 250 A 250:5 CTM00 2 25 to 500 A 500:5 CTM00 2 50 to 999 A 000:5 CTM00 2 NOTE: The current transformer (CTMxxx) must be placed in the same phase that is connected to terminal 9, phase L, see Fig. 2, page. Emotron AB 0-470-0r0 2

Technical Data 45 x 90 x 5 mm (.77" x 3.54" x 4.53") Dimension (WxHxD) 35 mm (.38 ) 26 mm (.02 ) 90 mm (3.54 ) 45 mm (.77 ) 5 mm (4.53 ) Mounting 35 mm DIN rail 46277 Weight Supply voltage (VAC) 0.3 kg (0.5 oz) 3x00to240, 3 x 380 to 500, 3 x 525 to 690 (±0%) NOTE: that these are separate voltage units; see table with order numbers on page 4. Frequency Current input Power consumption Start-up delay Stop delay Digital input terminal 3 Temperature input terminal 5 Relay output Fuse Terminal wire size Terminal tightening torque Repeatability power measurement 45 to 65 Hz Current transformer CTM00, 025, 050 or 00. (If rated current >00 A, CTM00 and a standard transformer) 6VA max. to70s to90 s For closing contact. Internal supply 5-30 VDC, shortcircuit current 0-20 ma Internal supply 5-30 VDC, short-circuit current 2 ma - 2.5 ma 5 A 240 VAC Resistive..5 A 240 VAC Pilot duty/ac2 0 A max. Use 75ºC copper (CU) wire only. 0.2 to 4.0 mm² single core (AWG2), 0.2 to 2.5 mm² flexible core (AWG4), stripped length 8 mm (0.32"). 0.56-0.79Nm (5-7 Ib-in) ± unit 24 h; 20ºC (68ºF) Temperature tolerance < 0.% / ºC Operating temperature range Storage temperature range Protection class RoHS directive Approved to -20ºC to 50ºC (-4ºF to 22ºF) -30ºC to 80ºC (-22ºF to 76ºF) IP20 2002/95/EC CE (up to 690 VAC), UL and cul (up to 600 VAC) 3 Emotron AB 0-470-0r0

Ordering numbers Ordering number Designation 0-20-20 Emotron DCM 3x00-240 VAC 0-20-40 Emotron DCM 3x380-500 VAC 0-20-50 Emotron DCM 3x525-690 VAC Technical Data for Current Transformer Type Dimensions (WxØ) Weight* Mounting CTM 00 27 (35) x Ø48 mm 0.20 kg 35 mm DIN rail 46277 CTM 025 27 (35) x Ø48 mm 0.20 kg 35 mm DIN rail 46277 CTM 050 27 (35) x Ø48 mm 0.20 kg 35 mm DIN rail 46277 CTM 00 45 (58) x Ø78 mm 0.50 kg 35 mm DIN rail 46277 *)Weight including m (39 inch) cable. Please note that the maximum length of the CTM cable is m and this cable must not be extended. 4. 3 0. 3 7 48 27 42 35 78 45 35 Fig. 3 Current transformer, CTM xxx. Emotron AB 0-470-0r0 4

Accessories and documentation Ordering number Designation 0-247-0 Current Transformer (CT) CTM00, max. 0 A 0-247-20 Current Transformer (CT) CTM025, max. 25 A 0-247-30 Current Transformer (CT) CTM050, max. 50 A 0-247-40 Current Transformer (CT) CTM00, max. 00 A 0-2368-00 Front Panel Kit (2x terminal covers included) 0-436-0 2x Terminal covers 0-220-00 Instruction manual (Swedish) 0-220-0 Instruction manual (English) EU (European Union) specifications EN 6000-6-3 EMC EN 6000-6-2 EN 6000-4-5 Electrical safety EN 60947-5- Rated insulated voltage 690 V Rated impulse withstand voltage 4000 V Pollution degree 2 Terminals 3, 4 and 5 are basic insulated from the line and relay terminals. 5 Emotron AB 0-470-0r0

Window Parameters Table 3 Window parameters and defaults Window Function Value Default Custom setting Master Slave 00 0 02 03 04 05 06 Alarm indication. Flashes when alarm present (window becomes active only on alarm). Symbol flashing. Remaining time to next pump start. Standard window during pause. When the DCM is SLAVE - - - appears. Symbol flashing and m (min) or s (second). Pumping Time (PT) since the last pump start. Displayed when pumping. When the DCM is MASTER and the DCM SLAVE is pumping - - - appears. Symbol flashing and m (min) or s (seconds). Pumping Time (PT) after last pump start when the pump is started on high-level switch. Displayed when pumping after high-level switch. Symbol flashing and m (min) or s (seconds). Measured power as percentage of the DCM s measurement range. Symbol %. Measured line voltage. Symbol V. Measured peak power as percentage of the DCM measurement range. Press - and (in this window) simultaneously for 3 seconds to reset the value. Symbol %. 720-5 min. 900 to 0 s 0 to 90 s. 5-720 min. 2 to 999 h 0 to 900 s 5-720 min. 2 to 999 h 0 to 25% 0 to 999 V 0 to 25% 0% 07 08 Total pumping time in hours. Press - and (in this window) simultaneously for 3 seconds to set the value to 0. Symbol. Total number of pump starts. Press - and (in this window) simultaneously for 3 seconds to set the value to 0. 0-99999 0 0-99999 0 09 Parameter lock. Symbol. Is displayed when parameter is locked. 0 to 999 Stop level. Symbol %. 0 to 25% 0% 2 Snore margin. Symbol %. 0 to 25% 4% 3 2 22 23 Type of Auto set. Auto set when the pump is snoring (_) (No liquid in the pit). Auto set when the pump is not snoring ( - ) (Liquid in the pit). Pit volume and level setting, see Fig., page 23 and Fig. 4, page 32. See also note on page 22. NOTE! The window is not shown when the DCM is SLAVE. Maximum pause time. NOTE! The window is not shown when the DCM is SLAVE. Symbol. Start-up delay. Symbol. ( - ) or (_) ( - ).0 to 0.0.0 0 to 900 s 5-720 min. to70s 600 s 5s Emotron AB 0-470-0r0 Window Parameters 6

Table 3 Window parameters and defaults Window Function Value Default Custom setting Master Slave 24 3 32 Stop delay. Symbol. High temperature on pump motor or motor protection alarm, terminal 5 (on). Turn off (OFF). Latched alarm, terminal 5 (on). Alarm not latched (OFF). Can only be used when window 3 is (on). to90s on / OFF on / OFF 4 Phase asymmetry permitted. OFF/ 5 to 50% 0% 42 5 52 53 6 7 72 Phase asymmetry latched alarm (on). Phase asymmetry alarm not latched. (OFF) Can be used when window 4 is set between 5-50%. Alarm relay (terminal 6 ALARM). NC: normally closed, NO: normally open. The window isn t shown when DCM is MASTER Operating relay to control the pump motors contactor (terminal 8 PUMP). NC: Relay contact is closed when pump is pumping. NO: Relay contact is open when pump is pumping. Digital input for closing contact: High-level switch 2 External reset 3 External Auto set (not used in dual-pump system). Measured current on the terminals S and S2. Desired DCM function: Single-pump system 2 Dual-pump system MASTER 3 Dual-pump system SLAVE. Pump alternating: (on) Alternate by each pump cycle (OFF) The SLAVE DCM only starts when the DCM MASTER indicates a fault code. NOTE! The window is not shown when the DCM is SLAVE. on / OFF NC/NO NC/NO 0-70 ma 2s OFF OFF OFF NO NC, 2, 3 on/off OFF 73 Pump starts on high-level switch. (on) Both pumps start. (OFF) one pump starts. NOTE! Window is not shown when the DCM is SLAVE. on/off OFF 99 Default settings (def). User adjustments mode (USr). def/usr def 7 Window Parameters Emotron AB 0-470-0r0

Emotron AB, Mörsaregatan 2, SE-250 24 Helsingborg, Sweden Tel: 46 42 6 99 00, Fax: 46 42 6 99 49 E-mail: info@emotron.se Internet: www.emotron.com Emotron AB 0-470-0r0 2009-06-0