Installation - Quick Reference Guide Off-Grid Systems

Similar documents
System description Off-Grid Systems with SUNNY ISLAND 4.4M / 6.0H / 8.0H

Quick Installation Manual Alpha ESS Battery with SMA Flexible Storage System V1.0

System description Multicluster Systems with Stand-Alone Grid or Increased Self-Consumption and Battery-Backup Function

System Description SMA FLEXIBLE STORAGE SYSTEM in the United Kingdom

PV Inverter SUNNY MINI CENTRAL 9000TL / 10000TL / 11000TL with Reactive Power Control

Operating Manual SUNNY ISLAND 3.0M / 4.4M / 6.0H / 8.0H SUNNY REMOTE CONTROL. SI30M-44M-60H-80H-BE-en-33 Version 3.3 SUNNY REMOTE CONTROL

Multi-Function Interface MULTI-FUNCTION RELAY

System Description SMA FLEXIBLE STORAGE SYSTEM with BatteryBackup Function

Wind Power Inverter WINDY BOY 5000A/6000A

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

System description SMA FLEXIBLE STORAGE SYSTEM

PV inverter SUNNY MINI CENTRAL 7000HV

Accessories for power generation plants in Italy SMA GRID GATE

Design of Off-Grid Systems with Sunny Island 4.4M / 6.0H / 8.0H Devices

Accessories for Stand-alone inverter SUNNY ISLAND GENMAN

System Monitoring SCHOOLMETERBOX AU

Planning Guidelines SMA SMART HOME The System Solution for more Independence

Operating Manual NA-BOX 12

Technical Information PV Inverters

Sunny Boy Accessories SUNNY BOY COMBINER BOX TLUS SBCBTL6

Charge controller SUNNY ISLAND CHARGER

Central Inverter SUNNY CENTRAL 500CP-JP / 500CP XT / 630CP XT / 720CP XT / 760CP XT / 800CP XT / 850CP XT / 900 CP XT

Wind power inverter WINDY BOY 5000-US/6000-US WINDY BOY 7000-US/8000-US. 1 Notes on this addendum. 1.1 Validity. 1.2 Target group

User Manual SMA FUEL SAVE CONTROLLER 2.0

Installation Manual SUNNY CENTRAL 500CP XT/630CP XT/720CP XT/ 760CP XT/800CP XT/850CP XT/900CP XT/1000CP XT

Central Inverter SUNNY CENTRAL 500HE-20/630HE-20/720HE-20/ 760HE-20/800HE-20

User Manual SMA FUEL SAVE CONTROLLER 2.0

Planning Guidelines SMA FLEXIBLE STORAGE SYSTEM WITH BATTERY-BACKUP FUNCTION

Lithium Power Supply

Wind Power Inverter WINDY BOY 1100LV

Version: 1.0 Mat.-Nr.: DBUS-WB50-80US

Technical Information Control of the Active Power Feed-In at the Grid-Connection Point with the SMA CLUSTER CONTROLLER

Operating Manual SUNNY BOY 3600 / 5000 SMART ENERGY BATTERY PACK SMART ENERGY

Off-Grid Inverter SUNNY ISLAND 4548-US/6048-US

Inverter / Charger Accessory for Steca Solarix PLI Phase / Parallel Kit. Installation and operating instructions Z01 17.

User s Manual. Automatic Switch-Mode Battery Charger

Planning Guidelines SMA SMART HOME

PV Inverter SUNNY BOY 3300/3800

PV Inverter SUNNY BOY 3300/3800

Installation Manual 485 Data Module Type B

Installation Manual 485 Data Module Type B

Installation Manual SMA POWER CONTROL MODULE

Installation Manual Retrofitting of the Option "Noise Reduction" SUNNY CENTRAL of the CP XT Series and SUNNY CENTRAL STORAGE

Sunny Island 3324/4248 User Manual

Simple and secure monitoring

Micro Inverter with Communication Unit SUNNY BOY 240-US SUNNY MULTIGATE-US

Installation and Operating Instructions. MPPT Solar System Controller ISC3040

Planning Guidelines SMA SMART HOME The System Solution for Greater Independence

Integrated Plant Control and Q on Demand 24/7 SUNNY TRIPOWER

Batteries in Sunny Island Systems List of Approved Batteries

2/10/50 AMP 12 VOLT BATTERY CHARGER/ ENGINE STARTER

BESS Labelling Location Sign Source Notes

AC CONVERTER / BATTERY CHARGER

Installation, Maintenance and Warranty Flat Plate Battery

OmniScan MX2. Getting Started Guide. Intended Use. Instruction Manual. Safety Signal Words

Installation and Operating Instructions. Solar System Controller ISC3030

Galaxy VM. Battery Breaker Box Installation 09/

Installation Manual. TS 48 Volt

I. Safety precautions

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

Installation Guidance

Dual-Lite Trident TRF 40 Wide Battery Cabinet 20-40kVA Systems USER MANUAL

PV inverter SUNNY BOY 2100TL

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

System Manual MEDIUM VOLTAGE STATION 600 / 1200 / 1800 for SUNNY TRIPOWER 60

Wind Power Inverter WINDY BOY 1200/1700

Installation Guide B-BOX Pro2.5 ~ 10.0

B-Box Pro 2.5~10.0 User Manual

User Manual. B-Box 2.5~10.0. B-Box user manual. Version: 1.1. Copyright BYD Company Limited. All rights reversed.

Freedom egen System End-of- Line Functional Checklist

Chapter 6. Batteries. Types and Characteristics Functions and Features Specifications and Ratings Jim Dunlop Solar

CP-250E-60/72-208/240-MC4 Microinverter with Modular Trunk Cable

Installation Instructions for Remote Mount HMI 211 Display Panel Kit A045J206

Installation Manual SMA SPEEDWIRE/WEBCONNECT DATA MODULE

Installation and Operating Instructions. Solar System Controller ISC3020

30,000mWh LITHIUM-POLYMER CAR JUMP STARTER USER S MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

How To AC Couple Grid Tied Inverters with OutBack Frequency Shifting Inverters

Installation Manual AUTOMATIC BACKUP UNIT

Lithium-Ion Phosphate Battery Phantom-S Product Manual

User Manual Solar Charge Controller 3KW

Technical Information Temperature Derating for Sunny Boy and Sunny Tripower

Sunny Backup 5000 Installation & Instruction Manual

Duo Battery Charge Controller

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

Lithium-Ion Phosphate Battery

Wide operating temperature range: Our battery will operate from -30C to (-22F) to 60C when it is fully charged.

Operating Manual SUNNY TRIPOWER 15000TL / 20000TL / 25000TL

Energy storage kits for residential and commercial customers. Ken Hobbs Technical Director, CCL Components Dean Kalek Technical Trainer, SMA Solar UK

Eclipse Solar Suitcase

OPERATION MANUAL BATTERY CHARGER DFC-10P DFC-50P DFC-450P DFC-650P

Installation Guide Kratos (B10L)

Installation Manual SMA SPEEDWIRE/WEBCONNECT DATA MODULE

Sentry Battery Charger. Installation and Operations Manual Section 75

Operating Manual MP-3739

DLT-U1100 UPS Uninterruptible Power Supply Manual V1.00. Industrial PCs applied in

Battery charger , A, B

Guardian Battery Charger Series. Installation and Operations Manual Section 75

Pure Sine Wave Inverter 600W-24V User Manual

IEEE IAS Atlanta Chapter

c-go 24V/6A 24V/8A 24V/12A

Transcription:

Installation - Quick Reference Guide Off-Grid Systems Off-Grid Systems with Sunny Island 6.0H / 8.0H Off-Grid-IAS-en-20 Version 2.0 ENGLISH

Legal Provisions SMA Solar Technology AG Legal Provisions The information contained in this document is the property of SMA Solar Technology AG. Publishing its content, either partially or in full, requires the written permission of SMA Solar Technology AG. Any internal company copying of the document for the purposes of evaluating the product or its correct implementation is allowed and does not require permission. SMA Warranty The current warranty conditions come enclosed with your device. These are also available online at www.sma-solar.com and can be downloaded and are available on paper from the usual sales channels if required. Trademarks All trademarks are recognized even if these are not marked separately. Missing designations do not mean that a product or brand is not a registered trademark. The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by SMA Solar Technology AG is under license. QR Code is a registered trademark of DENSO WAVE INCORPORATED. SMA Solar Technology AG Sonnenallee 1 34266 Niestetal Germany Tel. +49 561 9522-0 Fax +49 561 9522-100 www.sma.de E-mail: info@sma.de 2004 to 2014 SMA Solar Technology AG. All rights reserved. 2 Off-Grid-IAS-en-20 Installation - Quick Reference Guide

SMA Solar Technology AG Table of Contents Table of Contents 1 Information on this Document..................................................... 5 2 Safety........................................................................ 7 2.1 Intended Use......................................................................... 7 2.2 Target Group Qualifications.............................................................. 7 2.3 Safety Precautions..................................................................... 7 3 Information on Off-Grid Systems and System Description............................. 10 3.1 Information on Off-Grid Systems......................................................... 10 3.2 Off-Grid System Functions.............................................................. 11 3.3 Modular Design...................................................................... 12 3.3.1 Single System...........................................................................12 3.3.2 Single-Cluster System (Single-Phase).........................................................12 3.3.3 Single-Cluster System (Three-Phase).........................................................13 3.3.4 Multicluster System......................................................................13 3.4 Optional Components and Functions...................................................... 14 4 Single System................................................................. 15 4.1 Circuitry Overview.................................................................... 15 4.2 Connecting the Sunny Island............................................................ 16 4.3 Connecting RS485 to the Sunny WebBox.................................................. 17 4.4 Basic Configuration of the Sunny Island.................................................... 18 5 Single-Cluster System........................................................... 22 5.1 Single-Phase Single-Cluster System........................................................ 22 5.1.1 Circuitry Overview Single-Phase Single-Cluster System...........................................22 5.2 Circuitry Overview Three-Phase Single-Cluster System......................................... 23 5.3 Connecting the Sunny Island............................................................ 24 5.3.1 Connecting the Master...................................................................24 5.3.2 Connecting the Slaves....................................................................26 5.4 Connecting RS485 to the Sunny WebBox.................................................. 27 5.5 Performing Basic Configuration.......................................................... 28 6 Multicluster System............................................................ 33 6.1 Circuitry Overview and Connection of the Sunny Island Inverters................................ 33 6.2 Basic Configuration................................................................... 33 7 Commissioning................................................................ 38 7.1 Switching to Installer Mode............................................................. 38 7.2 Commissioning the Multifunction Relays.................................................... 38 7.3 Starting the System.................................................................... 39 7.4 Testing the Battery Current Sensor........................................................ 39 7.5 Testing the Generator.................................................................. 40 7.6 Testing the Load Shedding.............................................................. 40 7.7 Commissioning the Sunny WebBox....................................................... 41 7.8 Commissioning the PV System........................................................... 41 7.9 Completing Commissioning............................................................. 41 Installation - Quick Reference Guide Off-Grid-IAS-en-20 3

SMA Solar Technology AG Table of Contents 8 Contact...................................................................... 42 Installation - Quick Reference Guide Off-Grid-IAS-en-20 4

SMA Solar Technology AG 1 Information on this Document 1 Information on this Document Validity This document is valid for off-grid systems with the following Sunny Island inverter types from firmware version 3.0: SI8.0H-11 SI6.0H-11 Content and Structure of this Document This document summarizes the specific information on off-grid systems with Sunny Island inverters. Circuitry overviews of selected off-grid systems provide the basis as to how an off-grid system can be designed. The structure of the document specifies the chronological sequence for configuration and commissioning. This document does not replace the documentation of the individual products. You will find details and help in the event of difficulties in the documentation of the respective product. Target Group This document is intended for qualified persons. Only persons with the appropriate skills are allowed to perform the tasks described in this document (see Section 2.2 "Target Group Qualifications", page 7). Additional Information Links to additional information can be found at www.sma-solar.com: Document title Off-Grid Systems PV Inverters in Off-Grid Systems External Energy Sources Document type Planning Guidelines Technical Information Technical Information Symbols for Information Symbol Explanation Indicates a hazardous situation which, if not avoided, will result in death or serious injury Indicates a hazardous situation which, if not avoided, can result in death or serious injury Indicates a hazardous situation which, if not avoided, can result in minor or moderate injury Indicates a situation which, if not avoided, can result in property damage Information that is important for a specific topic or goal, but is not safety-relevant Indicates a requirement for meeting a specific goal Desired result A problem that might occur Installation - Quick Reference Guide Off-Grid-IAS-en-20 5

1 Information on this Document SMA Solar Technology AG Typographies Typography Usage Example bold Display messages Parameters Terminals Slots Elements to be selected Elements to be entered > Several elements that are to be selected [Button/Key] Nomenclature Button/key on the inverter to be selected or pressed Connect the grounding conductor to AC 2Gen/Grid. Select the parameter 235.01 GnAutoEna and set to Off. Select 600# Direct Access > Select Number. Press [ENTER]. Complete designation Sunny Boy, Sunny Mini Central, Sunny Tripower Battery charge controllers not offered by SMA Solar Technology AG AC voltage source that can form a stand-alone grid (e.g. diesel generator) Designation in this document PV inverter Charge controllers by a third-party supplier Generator The term parameter includes parameters with configurable values as well as parameters for displaying values. Abbreviations Abbreviation Designation Explanation AC Alternating Current DC Direct Current PV Photovoltaics 6 Off-Grid-IAS-en-20 Installation - Quick Reference Guide

SMA Solar Technology AG 2 Safety 2 Safety 2.1 Intended Use Off-grid systems with Sunny Island inverters are self-sufficient utility grids that are being fed with energy from several AC sources in the off-grid system (e.g. PV inverter), from a generator and/or with DC charge controllers (e.g. Sunny Island Charger). The Sunny Island inverters forms the off-grid system as a voltage source. The Sunny Island regulates the balance between the energy fed-in and energy used and has a management system with battery and generator management and load control. The Sunny Island can synchronize with a generator and connect directly, if necessary. When the stand-alone grid is connected to the generator, the voltage in the stand-alone grid is regulated by the generator. Off-grid systems with Sunny Island are single-phase or three-phase AC distribution grids. The locally valid standards and regulations must be observed. Loads in an off-grid system are not protected against supply failures. An off-grid system is not suitable for supplying life-sustaining medical devices. Several Sunny Island inverters can be operated in an off-grid system. Three Sunny Island inverters are connected parallel on the DC side and form a cluster. A cluster can consist of several device types. The circuitry of the Sunny Island inverters forming a cluster and the circuitry of several clusters in a system must be carried out in accordance with this documentation (see Section 3.3 "Modular Design", page 12). The output power of the AC sources in the stand-alone grid is controlled via the frequency and voltage of the stand-alone grid. The AC sources must be suitable for stand-alone grid operation with Sunny Island (see Technical Information "PV Inverters in Off-Grid Systems" at www.sma-solar.com). The maximum output power of the AC sources in an off-grid system must be observed (see Sunny Island installation manual). The battery management must capture the DC current when charging and discharging the battery. If third-party supplied charge controllers, DC loads or more than four Sunny Island Charger devices are installed in an off-grid system, an additional battery current sensor must be installed (see Sunny Island installation manual). The Sunny Island uses lead-acid batteries or lithium-ion batteries for energy storage in off-grid systems. Ensure that the battery room is sufficiently ventilated when using lead-acid batteries (see battery manufacturer's documentation). The battery management of a lithium-ion battery that might be connected must be compatible with the Sunny Island. The lithium-ion battery must be able to supply enough current at maximum output power of the Sunny Island (the technical data see the Sunny Island installation manual). The individual products in the off-grid system must be used for their intended purpose (see documentation of each product). Any use of the system other than that described in the Intended Use section does not qualify as appropriate. The enclosed documentation is an integral part of the products. Keep the documentation in a convenient place for future reference and observe all instructions contained therein. 2.2 Target Group Qualifications Qualified persons must have the following skills: Training in how to deal with the dangers and risks associated with installing and using electrical devices and batteries Training in the installation and commissioning of electrical devices Knowledge of and adherence to the local technical connection conditions, standards and directives Knowledge of and adherence to the Sunny Island documentation and all safety precautions 2.3 Safety Precautions This section contains safety precautions that must be observed at all times when working on or with the system. To prevent personal injury or property damage and to ensure long-term operation of the system, read this section carefully and follow all safety precautions at all times. Installation - Quick Reference Guide Off-Grid-IAS-en-20 7

2 Safety SMA Solar Technology AG Danger to life due to incompatible lithium-ion battery An incompatible lithium-ion battery can lead to a fire or an explosion. With incompatible lithium-ion batteries, it is not ensured that the battery management will protect the battery. Ensure that the battery is from one of the following manufacturers and has been approved for Sunny Island inverters by the manufacturer: Akasol Dispatch Energy LG Chem Leclanché SAFT Samsung Sony Danger to life due to explosive gases Explosive gases may escape from the battery and cause an explosion. This can result in death or serious injury. Protect the battery environment from open flames, embers or sparks. Install, operate and maintain the battery in accordance with the manufacturer's specifications. Do not heat or burn the battery above the temperature permitted. Ensure that the battery room is sufficiently ventilated. Danger to life from electric shock due to damaged components Operating a damaged component can lead to hazardous situations that result in death or serious injuries due to electric shock. Only use the off-grid system when it is technically faultless and in an operationally safe state. Regularly check the off-grid system for visible damages. Ensure that all safety equipment is freely accessible at all times. Make sure that all safety equipment is in good working order. Danger to life from electric shock due to live voltage High voltages are present in the off-grid system. When covers are removed (e.g. an enclosure lid), live components can be touched which can result in death or serious injury due to electric shock. When carrying out any work on the electrical installation, wear suitable personal protective equipment. Turn off or disconnect the following components from voltage sources in the given order: Loads Generator Sunny Island In the distribution board, the circuit breakers of the Sunny Island and of the generator Load-break switch of the battery Ensure that the off-grid system cannot be reconnected. Open the enclosure lid of the Sunny Island and ensure that no voltage is present in the device. Ground and short-circuit the AC conductors outside the Sunny Island. Cover or shield any adjacent live components. 8 Off-Grid-IAS-en-20 Installation - Quick Reference Guide

SMA Solar Technology AG 2 Safety Chemical burns and poisoning due to battery electrolyte If handled inappropriately, electrolyte from the battery can burn the eyes, respiratory system and skin, and emit toxic fumes. This may result in blindness and serious chemical burns. Protect the battery enclosure against destruction. Do not open or deform the battery. Whenever working on the battery, wear suitable personal protective equipment such as rubber gloves, apron, rubber boots and goggles. In case of acid splashing into eyes or on skin, rinse thoroughly with clear water for quite some time and consult a doctor. If acid fumes have been inhaled, consult a doctor. Install, operate, maintain and dispose of the battery in accordance with the manufacturer's specifications. Risk of injury due to short-circuit currents Short-circuit currents in the battery can cause heat build-up and electric arcs. Burns or eye injuries due to flashes may result. Remove watches, rings and other metal objects. Use insulated tools. Do not place tools or metal parts on the battery. Risk of crushing injuries due to movable generator parts Moving parts in the generator can crush or sever body parts. A generator can be started automatically by the Sunny Island. Only operate the generator with the safety equipment. Install, maintain, and operate the generator according to the manufacturer standards. Damage to the battery due to incorrect settings Incorrect settings can lead to premature aging of the battery. Settings of the parameters in the menu 220# Battery influence the charging behavior of the Sunny Island. Ensure that the values recommended by the battery manufacturer are set for the battery (refer to the technical data of the battery in the manufacturer documentation). Destruction of components due to electrostatic discharge (ESD) When enclosure parts have been removed, components (e.g. Sunny Island or PV inverter) can be damaged or destroyed by touching electronic components or connections. Do not touch electronic components in open components. Ground yourself before touching a connection. Installation - Quick Reference Guide Off-Grid-IAS-en-20 9

3 Information on Off-Grid Systems and System Description SMA Solar Technology AG 3 Information on Off-Grid Systems and System Description 3.1 Information on Off-Grid Systems Information on batteries Lithium-ion batteries in off-grid systems In order to meet the requirements of off-grid systems, the Sunny Island has a high overload capacity. This overload capacity requires the battery to supply sufficient current. This ampacity cannot be expected with lithium-ion batteries. Check with the battery manufacturer whether their battery is suitable for off-grid systems with Sunny Island inverters. Pay special attention to the current-carrying ampacity. Recommendations Regarding Battery Capacity SMA Solar Technology AG recommends the following minimum battery capacities. Minimum battery capacity per Sunny Island inverters: SI6.0H: 190 Ah SI8.0H: 250 Ah Minimum battery capacity per 1,000 Wp power of the PV system: 100 Ah The sum of the individual battery capacities is the total minimum battery capacity and applies to a ten-hour electric discharge (C10). It is required to observe the minimum battery capacity for a stable operation of the system. Information regarding clusters Device types within a cluster The device types of the Sunny Island inverters within a cluster can be different. If the device types within a cluster are different, the master must be a SI8.0H. The clusters in a multicluster system can consist of different Sunny Island inverter types. Connection of Sunny Island inverters in single-phase off-grid systems In a single-phase single cluster system, the following cable lengths and conductor cross-sections must be designed the same way: From the generator to each Sunny Island From each Sunny Island to the AC distribution board From the BatFuse to each Sunny Island The same design is a requirement for a stable and symmetrical operation of the off-grid system. Maximum PV system power In off-grid systems, the maximum PV system power depends on the total power of the Sunny Island inverters. Maximum output power of the PV system per SI6.0H: 9,200 W Maximum output power of the PV system per SI8.0H: 12,000 W Observing the minimum output power of the PV system is required for a stable operation of the off-grid system. 10 Off-Grid-IAS-en-20 Installation - Quick Reference Guide

SMA Solar Technology AG 3 Information on Off-Grid Systems and System Description 3.2 Off-Grid System Functions Off-grid systems with Sunny Island are self-sufficient utility grids that are being fed with energy from several AC sources in the off-grid system (e.g. PV inverter), from an external AC voltage source (e.g. diesel generator) and/or with DC charge controllers (e.g. Sunny Island Charger). The Sunny Island forms the off-grid system as a voltage source and supplies active and reactive power. The Sunny Island regulates the balance between the energy fed-in and energy used and has a management system with battery and generator management and load control. In order to be able to distribute the output power of the off-grid system to the loads, several Sunny Island inverters can be interconnected modularly. Battery Management Battery management of the Sunny Island is based on precise determination of the state of charge. By combining the three most common methods for capturing the state of charge, the Sunny Island reaches a measuring accuracy of more than 95%. This way, overcharge and deep discharge of the battery are avoided. A further feature of battery management is the extremely gentle charging control. It automatically selects the optimum charging strategy for the battery type and the situation in which it is used. This means that overcharging can be reliably prevented and that the battery can be fully charged regularly. The available charge energy is used optimally at all times (see Technical Information "Battery Management" at www.sma-solar.com). Generator Management The Sunny Island generator management allows for uninterruptible connection of the off-grid system to the generator and uninterruptible isolation from the generator. The generator management controls the generator via a start and stop signal. A generator current control ensures that the generator always remains at the optimum operating point. The generator management allows the use of generators that have a low output power in proportion to the nominal load (see Technical Document "Sunny Island - Generator Whitepaper" at www.sma-solar.com) Load Control The load control allows for controlling the AC sources in stand-alone grids, controlling a generator and the specific disconnection of loads. The AC sources in the stand-alone grid are limited in their power output by the stand-alone grid frequency. In case of excess energy, the load control increases the power frequency. This limits the output power of the PV inverters, for example. If there is not enough energy available for all loads or the battery should be preserved, load control can request energy from a generator by means of the generator management. The generator management starts the generator and the off-grid system is supplied with sufficient energy. If there is no generator present in the off-grid system or the energy is not sufficient despite the generator being available, load control turns the loads off using load shedding. All loads are shed simultaneously with one-stage load shedding. A load shedding contactor sheds the non-critical loads during the first stage with two-stage load shedding. Not until the state of charge further declines, the remaining loads are shed during the second stage. This can further increase the availability of the off-grid system for critical loads. Installation - Quick Reference Guide Off-Grid-IAS-en-20 11

3 Information on Off-Grid Systems and System Description SMA Solar Technology AG 3.3 Modular Design 3.3.1 Single System Figure 1: Block circuit diagram In a single system, one Sunny Island forms a single-phase stand-alone grid. 3.3.2 Single-Cluster System (Single-Phase) Figure 2: Block circuit diagram In a single-phase single-cluster system up to three Sunny Island inverters are connected to one battery forming a cluster. The Sunny Island inverters are connected on the AC side to the same line conductor. The Sunny Island inverters types can vary. If the device types within a cluster are different, the master must be a SI8.0H. 12 Off-Grid-IAS-en-20 Installation - Quick Reference Guide

SMA Solar Technology AG 3 Information on Off-Grid Systems and System Description 3.3.3 Single-Cluster System (Three-Phase) Figure 3: Block circuit diagram In a three-phase single-cluster system up to three Sunny Island inverters are connected to one battery forming a cluster. The Sunny Island inverters are connected on the AC side to three different line conductors. The Sunny Island inverters types can vary. If the device types within a cluster are different, the master must be a SI8.0H. 3.3.4 Multicluster System Figure 4: Block circuit diagram Multicluster systems consist of several three-phase clusters. The individual clusters must be connected to a Multicluster Box. The Multicluster Box is the AC main distribution board in a multicluster system. The Sunny Island inverter types can be different. If the device types within a cluster are different, the master must be a SI8.0H. Installation - Quick Reference Guide Off-Grid-IAS-en-20 13

3 Information on Off-Grid Systems and System Description SMA Solar Technology AG 3.4 Optional Components and Functions The following components can be used optionally in an off-grid system: Devices Sunny WebBox Sunny Island Charger 50 Battery current sensor Description Remote monitoring and system configuration of the off-grid system Charge controller for off-grid systems Shunt for measuring the battery current Sunny Island inverters offer the following functions for off-grid systems via two multifunction relays (see Sunny Island installation manual): Function Controlling generators Control of load-shedding contactors Time control for external processes Display of operating states and warning messages Control of a battery-room fan Control of an electrolyte pump Use of excess energy Description A multifunction relay is activated when requested by the Sunny Island generator management. With the multifunction relay, you can control generators with electrical remote-start function or connect a signal generator for generators with no autostart function. A multifunction relay is activated depending on the state of charge of the battery. Depending on the configuration, you can install a one-stage load shedding with one multifunction relay or a two-stage load shedding with two multifunction relays. You can also adjust the thresholds for the state of charge of the battery depending on the time of day. External processes can be time-controlled with a multifunction relay. You can connect message devices to the multifunction relay to display operating states and warning messages of the Sunny Island. One of the following operating states and warning messages can be displayed for each multifunction relay: The generator is running and is connected. A Sunny Island displays an error message of level 2 or higher. Only the error messages within a cluster are evaluated here. A Sunny Island displays a warning. Only the warnings within a cluster are evaluated here. The Sunny Island is in operation in the single system. The respective cluster is in operation in a cluster system. The Sunny Island is in derating in a single system. The respective cluster is in derating in a cluster system. The multifunction relay is activated when the charging current leads to the battery emitting gasses. A connected battery room fan is being switched on for one hour at least. Depending on the nominal energy throughput, the multifunction relay is activated at least once a day. During the constant voltage phase, a multifunction relay is activated and thus controls additional loads that can put any excess energy of AC sources in the stand-alone grid (e.g. of a PV system) to good use. 14 Off-Grid-IAS-en-20 Installation - Quick Reference Guide

SMA Solar Technology AG 4 Single System 4 Single System 4.1 Circuitry Overview Figure 5: Single system Installation - Quick Reference Guide Off-Grid-IAS-en-20 15

4 Single System SMA Solar Technology AG 4.2 Connecting the Sunny Island Figure 6: Connecting the Sunny Island Position Designation Description/information A AC power cable of the stand-alone grid Sunny Island: connection to AC1 Loads/SunnyBoys terminals L, N und PE Maximum conductor cross-section: 16 mm² B AC power cable of the generator Sunny Island: connection to AC2 Gen/Grid terminals L, N und PE Maximum conductor cross-section: 16 mm² The Sunny Island must be connected to the ground potential on terminals AC1 or AC2 via a grounding conductor. The conductor cross-section of the grounding conductor must be 10 mm² or larger. If the conductor cross-section is smaller, an additional grounding conductor on the enclosure with the conductor cross-section of the AC power cable must connect the Sunny Island with the ground potential. C DC+ cable Battery connection D DC cable Conductor cross-section: 50 mm² to 95 mm² E Control cable generator Sunny Island: Relay1 NO and Relay1 C terminals Conductor cross-section: 0.2 mm² to 2.5 mm² 16 Off-Grid-IAS-en-20 Installation - Quick Reference Guide

SMA Solar Technology AG 4 Single System Position Designation Description/information F Measuring cable of the battery temperature sensor 4.3 Connecting RS485 to the Sunny WebBox Sunny Island: BatTmp terminal You only have to connect a battery temperature sensor if lead-acid batteries are used. Mount the battery temperature sensor in the middle of the battery connection, in the upper third of the battery cell. G Control cable load shedding Sunny Island: connect the control cable to terminals Relay2 NO and BatVtg. Connect the terminals Relay2 C und BatVtg+ within the Sunny Island. Conductor cross-section: 0.2 mm² to 2.5 mm² H RS485 communication bus Sunny Island: on SI-COMSMA.BGx terminal ComSmaOut connection to further nodes, e.g. PV inverter A terminator must terminate the RS485 communication bus on the last bus node. I Data cable to Sunny Remote Control display Sunny Island: Display terminal K Data cable to Sunny Island Charger Sunny Island: ComSync In terminal An additional data cable needs to be connected from the ComSync Out terminal to the battery only when lithium-ion batteries are used. The communication bus must be equipped with a terminator on both ends. L RS485 communication bus Sunny Island: on SI-COMSMA.BGx terminal ComSmaIn Sunny WebBox: terminal SMACOM Data cable to lithium-ion battery Only with lithium-ion batteries: additional data cable on ComSync In terminal Figure 7: Connection of the RS485 communication bus to the Sunny WebBox Position Designation Description/information A Jumper J1A Terminator If the Sunny WebBox is located at the end of the communication bus, a jumper must be inserted. If the Sunny WebBox is installed between two nodes, the jumper must be removed. B Jumper J1B and J1C Signal bias voltage Make sure that both jumpers are inserted. Installation - Quick Reference Guide Off-Grid-IAS-en-20 17

4 Single System SMA Solar Technology AG Position Designation Description/information C SMACOM RS485 connection 2: Signal Data+ (A), color coding of the insulated conductor: green with white stripes 5: Signal GND, color coding of the insulated conductor: orange with white stripes 7: Signal Data (B), color coding of the insulated conductor: white with green stripes 4.4 Basic Configuration of the Sunny Island Danger to life due to incompatible lithium-ion battery An incompatible lithium-ion battery can lead to a fire or an explosion. With incompatible lithium-ion batteries, it is not ensured that the battery management will protect the battery. Ensure that the battery is from one of the following manufacturers and has been approved for Sunny Island inverters by the manufacturer: Akasol Dispatch Energy LG Chem Leclanché SAFT Samsung Sony Damage to the battery due to incorrect settings The battery parameters influence the charging behavior of the Sunny Island. The battery can be damaged by incorrect settings of the parameters for battery type, nominal voltage and capacity. Ensure that the values recommended by the battery manufacturer are set for the battery during basic configuration (refer to the technical data of the battery in the manufacturer documentation). In the basic configuration, configure the battery capacity for a ten-hour electric discharge (C10). The battery manufacturer specifies the battery capacity in relation to discharge time. Requirements: The off-grid system must be installed according to the circuitry (see Section 4.1, page 15). All component enclosures must be closed except for the BatFuse. This protects all live components from being touched. All circuit breakers in the AC distribution board must be open. Thus, the Sunny Island is not connected to an AC source. Procedure: Check the wiring (see the Sunny Island installation manual) Lock all components except for the BatFuse. This protects all live components from being touched. 18 Off-Grid-IAS-en-20 Installation - Quick Reference Guide

SMA Solar Technology AG 4 Single System Close the BatFuse load-break switch and press the activation button on the Sunny Island. When the Sunny Remote Control shows <Init System>, press and hold the button on the Sunny Remote Control. An acoustic signal sounds three times and the Sunny Remote Control displays the Quick Configuration Guide. Turn the button on the Sunny Remote Control and select New System. Press the button. This confirms your selection of New System. A confirmation message appears. Set Y and press the button. Set the date. Installation - Quick Reference Guide Off-Grid-IAS-en-20 19

4 Single System SMA Solar Technology AG Set the time. Set OffGrid. Set the battery type: VRLA: lead-acid battery with electrolyte absorbed in glass mat or immobilized in gel FLA: lead-acid battery with liquid electrolyte LiIon_Ext-BMS: lithium-ion battery Set the nominal voltage of the battery. Set the battery capacity for ten-hour electric discharge (for determining the battery capacity, see the Sunny Island installation manual). Set the battery capacity for ten-hour electric discharge (for determining the battery capacity, see the Sunny Island installation manual). Setting the line voltage and power frequency of the stand-alone grid: 230V_50Hz: line voltage 230 V, power frequency 50 Hz 220V_60Hz: line voltage 220 V, power frequency 60 Hz 20 Off-Grid-IAS-en-20 Installation - Quick Reference Guide

SMA Solar Technology AG 4 Single System Set 1Phs: Set the type of energy sources: PvOnly: no generator is connected to terminal AC1 of the Sunny Island. Gen: one generator is connected on terminal AC1 of the Sunny Island. Set the maximum generator current for continuous operation. Confirm the basic configuration with Y. Decline Setup Slaves? with N. The basic configuration is complete. If an SD memory card is inserted into the Sunny Remote Control, the message Do not remove MMC/SD card... appears and the SD memory card is integrated in the file system. Commission the off-grid system (see Section 7, page 38). Installation - Quick Reference Guide Off-Grid-IAS-en-20 21

5 Single-Cluster System SMA Solar Technology AG 5 Single-Cluster System 5.1 Single-Phase Single-Cluster System 5.1.1 Circuitry Overview Single-Phase Single-Cluster System Figure 8: Circuitry overview single-phase single-cluster system 22 Off-Grid-IAS-en-20 Installation - Quick Reference Guide

SMA Solar Technology AG 5 Single-Cluster System 5.2 Circuitry Overview Three-Phase Single-Cluster System Figure 9: Circuitry overview three-phase single-cluster Installation - Quick Reference Guide Off-Grid-IAS-en-20 23

5 Single-Cluster System SMA Solar Technology AG 5.3 Connecting the Sunny Island 5.3.1 Connecting the Master Figure 10: Connection of the master in the single-cluster system Position Designation Description/information A AC power cable of the stand-alone grid Sunny Island: connection to AC1 Loads/SunnyBoys terminals L, N and PE Stand-alone grid: connect master to line conductor L1. For a single-phase system, the cable length and the conductor cross-section must be identical on each Sunny Island. Maximum conductor cross-section: 16 mm² B AC power cable of the generator Sunny Island: connection to AC2 Gen/Grid terminals L, N and PE Generator: connect master to line conductor L1. Maximum conductor cross-section: 16 mm² For a single-phase system, the cable length and the conductor cross-section must be identical on each Sunny Island. The Sunny Island must be connected via a grounding conductor on the AC1 or AC2 terminal to the ground potential. The conductor cross-section of the grounding conductor must be 10 mm² or larger. If the conductor cross-section is smaller, an additional grounding conductor on the enclosure with the conductor cross-section of the AC power cable must connect the Sunny Island with the ground potential. 24 Off-Grid-IAS-en-20 Installation - Quick Reference Guide

SMA Solar Technology AG 5 Single-Cluster System Position Designation Description/information C DC+ cable Battery connection D DC cable For a single-phase system, the cable length and the conductor cross-section must be identical on each Sunny Island. Conductor cross-section: 50 mm² to 95 mm² E Control cable generator Sunny Island: Relay1 NO and Relay1 C terminals Conductor cross-section: 0.2 mm² to 2.5 mm² F Measuring cable of the battery temperature sensor Sunny Island: BatTmp terminal You only have to connect a battery temperature sensor if lead-acid batteries are used. Mount the battery temperature sensor in the middle of the battery connection, in the upper third of the battery cell. G Control cable load shedding Connect the control cable to terminals Relay2 NO and BatVtg in the Sunny Island. Connect the terminals Relay2 C and BatVtg+ within the Sunny Island. Conductor cross-section: 0.2 mm² to 2.5 mm² H RS485 communication bus Sunny Island: on SI-COMSMA.BGx terminal ComSmaOut connection to further nodes, e.g. PV inverter A terminator must terminate the RS485 communication bus on the last bus node. I Data cable to Sunny Remote Control display Sunny Island: Display terminal K Data cable for the internal communication in the cluster Sunny Island: ComSync Out terminal Only with lithium-ion batteries: additional data cable on terminal ComSync In The communication bus must be equipped with a terminator on both ends. L RS485 communication bus Sunny Island: on SI-COMSMA.BGx terminal ComSmaIn Sunny WebBox: terminal SMACOM Data cable to lithium-ion battery Only with lithium-ion batteries: additional data cable on terminal ComSync In Installation - Quick Reference Guide Off-Grid-IAS-en-20 25

5 Single-Cluster System SMA Solar Technology AG 5.3.2 Connecting the Slaves Figure 11: Connection of the slaves in a single-cluster system Position Designation Description/information A AC power cable of the stand-alone grid Sunny Island: connection to AC1 Loads/SunnyBoys terminals L, N and PE Stand-alone grid: connect slave 1 to line conductor L2, and connect slave 2 to line conductor L3. For a single-phase system, the cable length and the conductor cross-section must be identical on each Sunny Island. Maximum conductor cross-section: 16 mm² B AC power cable of the generator Sunny Island: connection of the generator to AC2 Gen/Grid terminals L, N and PE Generator: connect slave 1 to line conductor L2, and connect slave 2 to line conductor L3. Maximum conductor cross-section: 16 mm². For a single-phase system, the cable length and the conductor cross-section must be identical on each Sunny Island. The Sunny Island must be connected via a grounding conductor on the AC1 or AC2 terminal to the ground potential. The conductor cross-section of the grounding conductor must be 10 mm² or larger. If the conductor cross-section is smaller, an additional grounding conductor on the enclosure with the conductor cross-section of the AC power cable must connect the Sunny Island with the ground potential. 26 Off-Grid-IAS-en-20 Installation - Quick Reference Guide

SMA Solar Technology AG 5 Single-Cluster System Position Designation Description/information C DC+ cable Battery connection D DC cable For a single-phase system, the cable length and the conductor cross-section must be identical on each Sunny Island. Conductor cross-section: 50 mm² to 95 mm² E F Data cable for the internal communication in the cluster 5.4 Connecting RS485 to the Sunny WebBox Sunny Island: ComSync In terminal SunnyIsland: ComSync Out terminal On slave 2 either connect the data cable of the Sunny Island Charger or insert the terminator into the terminal. Figure 12: Connection of the RS485 communication bus to the Sunny WebBox Position Designation Description/information A Jumper J1A Terminator If the Sunny WebBox is located at the end of the communication bus, a jumper must be inserted. If the Sunny WebBox is installed between two nodes, the jumper must be removed. B Jumper J1B and J1C Signal bias voltage Make sure that both jumpers are inserted. C SMACOM RS485 connection 2: Signal Data+ (A), color coding of the insulated conductor: green with white stripes 5: Signal GND, color coding of the insulated conductor: orange with white stripes 7: Signal Data (B), color coding of the insulated conductor: white with green stripes Installation - Quick Reference Guide Off-Grid-IAS-en-20 27

5 Single-Cluster System SMA Solar Technology AG 5.5 Performing Basic Configuration Danger to life due to incompatible lithium-ion battery An incompatible lithium-ion battery can lead to a fire or an explosion. With incompatible lithium-ion batteries, it is not ensured that the battery management will protect the battery. Ensure that the battery is from one of the following manufacturers and has been approved for Sunny Island inverters by the manufacturer: Akasol Dispatch Energy LG Chem Leclanché SAFT Samsung Sony Damage to the battery due to incorrect settings The battery parameters influence the charging behavior of the Sunny Island. The battery can be damaged by incorrect settings of the parameters for battery type, nominal voltage and capacity. Ensure that the values recommended by the battery manufacturer are set for the battery during basic configuration (refer to the technical data of the battery in the manufacturer documentation). In the basic configuration, configure the battery capacity for a ten-hour electric discharge (C10). The battery manufacturer specifies the battery capacity in relation to discharge time. Requirements: The off-grid system must be installed according to the circuitry (see Section 5.1.1, page 22 and Section 5.2, page 23). All component enclosures must be closed except for the BatFuse. This protects all live components from being touched. All circuit breakers in the AC distribution board must be open. Thus, the Sunny Island is not connected to an AC source. The Sunny Remote Control must be connected to the master. This determines which Sunny Island is the master during the basic configuration. Procedure: Check the wiring (see the Sunny Island installation manual) Lock all components except for the BatFuse. This protects all live components from being touched. 28 Off-Grid-IAS-en-20 Installation - Quick Reference Guide

SMA Solar Technology AG 5 Single-Cluster System Close the BatFuse and press and hold the activation button on the master until an acoustic signal sounds. When the Sunny Remote Control shows <Init System>, press and hold the button on the Sunny Remote Control. An acoustic signal sounds three times and the Sunny Remote Control displays the Quick Configuration Guide. Turn the button on the Sunny Remote Control and select New System. Press the button. This confirms your selection of New System. A confirmation message appears. Set Y and press the button. This confirms your selection. Set the date. Installation - Quick Reference Guide Off-Grid-IAS-en-20 29

5 Single-Cluster System SMA Solar Technology AG Set the time. Set OffGrid. Set the battery type: VRLA: lead-acid battery with electrolyte absorbed in glass mat or immobilized in gel FLA: lead-acid battery with liquid electrolyte LiIon_Ext-BMS: lithium-ion battery Set the nominal voltage of the battery. Set the battery capacity for ten-hour electric discharge (for determining the battery capacity, see the Sunny Island installation manual). Set the battery capacity for ten-hour electric discharge (for determining the battery capacity, see the Sunny Island installation manual). Setting the line voltage and power frequency of the stand-alone grid: 230V_50Hz: line voltage 230 V, power frequency 50 Hz 220V_60Hz: line voltage 220 V, power frequency 60 Hz 30 Off-Grid-IAS-en-20 Installation - Quick Reference Guide

SMA Solar Technology AG 5 Single-Cluster System Set the number of line conductors in the system: 1Phase: single-phase off-grid system 3Phase: three-phase off-grid system Set SingleClst. Set the type of energy sources. PvOnly: no generator is connected to terminal AC1 of the Sunny Island. Gen: a generator is connected to terminal AC1 of the Sunny Island. Set the maximum generator current per line conductor for continuous operation. Confirm the basic configuration with Y. Confirm Setup Slaves? with Y. This prompt only occurs with single-phase systems. Wait until the upper LED (inverter LED) on slave 1 is flashing and the Sunny Remote Control is displaying To identify Slave1 press Tss on the Slv. Installation - Quick Reference Guide Off-Grid-IAS-en-20 31

5 Single-Cluster System SMA Solar Technology AG Press the start-stop button on slave 1. Wait until the Sunny Remote Control displays To identify Slave2, press Tss on the Slv. Press the button on the Sunny Remote Control in off-grid systems without slave 2. In off-grid systems with slave 2, wait until the inverter LED blinks on slave 2. Press the start-stop button on slave 2. The basic configuration is complete. If an SD memory card is inserted into the Sunny Remote Control, the message Do not remove MMC/SD card... appears and the SD memory card is integrated in the file system. Commission the off-grid system (see Section 7, page 38). 32 Off-Grid-IAS-en-20 Installation - Quick Reference Guide

SMA Solar Technology AG 6 Multicluster System 6 Multicluster System 6.1 Circuitry Overview and Connection of the Sunny Island Inverters You can find a circuitry overview in the Multicluster Box documentation. 6.2 Basic Configuration Danger to life due to incompatible lithium-ion battery An incompatible lithium-ion battery can lead to a fire or an explosion. With incompatible lithium-ion batteries, it is not ensured that the battery management will protect the battery. Ensure that the battery is from one of the following manufacturers and has been approved for Sunny Island inverters by the manufacturer: Akasol Dispatch Energy LG Chem Leclanché SAFT Samsung Sony Damage to the battery due to incorrect settings The battery parameters influence the charging behavior of the Sunny Island. The battery can be damaged by incorrect settings of the parameters for battery type, nominal voltage and capacity. Ensure that the values recommended by the battery manufacturer are set for the battery during basic configuration (refer to the technical data of the battery in the manufacturer documentation). In the basic configuration, configure the battery capacity for a ten-hour electric discharge (C10). The battery manufacturer specifies the battery capacity in relation to discharge time. Requirements: The off-grid system must be installed according to the circuitry (see Multicluster Box documentation). In the Multicluster Box all Sunny Island circuit breakers must be open. As a result, the Sunny Island inverters are not connected to an AC source. The Sunny Remote Control must be connected to the master of each cluster. This determines which Sunny Island is the master during the basic configuration. Procedure: Check the wiring (see the Sunny Island installation manual) Lock all components except for the BatFuse. This protects all live components from being touched. Installation - Quick Reference Guide Off-Grid-IAS-en-20 33

6 Multicluster System SMA Solar Technology AG Close the BatFuse and press and hold the activation button on each master until you hear an acoustic signal. When the Sunny Remote Control shows <Init System>, press and hold the button on the Sunny Remote Control. An acoustic signal sounds three times and the Sunny Remote Control displays the Quick Configuration Guide. Turn the button on the Sunny Remote Control and select New System. Press the button. This confirms your selection of New System. A confirmation message appears. Set Y and press the button. Set the date. 34 Off-Grid-IAS-en-20 Installation - Quick Reference Guide

SMA Solar Technology AG 6 Multicluster System Set the time. Set OffGrid. Set the battery type: VRLA: lead-acid battery with electrolyte absorbed in glass mat or immobilized in gel FLA: lead-acid battery with liquid electrolyte LiIon_Ext-BMS: lithium-ion battery Set the nominal voltage of the battery. Set the battery capacity for ten-hour electric discharge (for determining the battery capacity, see the Sunny Island installation manual). Set the battery capacity for ten-hour electric discharge (for determining the battery capacity, see the Sunny Island installation manual). Setting the line voltage and power frequency of the stand-alone grid: 230V_50Hz: line voltage 230 V, power frequency 50 Hz 220V_60Hz: line voltage 220 V, power frequency 60 Hz Installation - Quick Reference Guide Off-Grid-IAS-en-20 35

6 Multicluster System SMA Solar Technology AG Set 3Phase: Set MultiClst: Set the type of cluster: MainClst: the cluster is a main cluster ExtnClst: the cluster is an extension cluster Set the device type of the Multicluster Box. Tip: the device type is indicated on the type label of the Multicluster Box. Set the address of the extension cluster, e.g. set extension cluster 1 to 1. Set the maximum generator current per line conductor for continuous operation. Confirm the basic configuration with Y. Wait until the upper LED (inverter LED) on slave 1 is flashing and the Sunny Remote Control is displaying To identify Slave1, press Tss on the Slv. 36 Off-Grid-IAS-en-20 Installation - Quick Reference Guide

SMA Solar Technology AG 6 Multicluster System Press the start-stop button on slave 1. Wait until the inverter LED on slave 2 is flashing and the Sunny Remote Control is displaying To identify Slave2, press Tss on the Slv. Press the start-stop button on slave 2. The basic configuration is complete. If an SD memory card is inserted into the Sunny Remote Control, the message Do not remove MMC/SD card... is displayed and the SD memory card is integrated in the file system. Configure all other clusters. For this purpose, perform the steps of the Quick Configuration Guide for each master separately. Commission the off-grid system (see Section 7, page 38). Installation - Quick Reference Guide Off-Grid-IAS-en-20 37