Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

Similar documents
Circular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en

Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

Type CF FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, FLEXIBLE ALUMINIUM CONSTRUCTION

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

Ceiling swirl diffusers with perforated face plate

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

Parts and characteristics

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

CAV controllers Type RN

Heat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en

Type TVZ. VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

Slot diffusers for ceiling installation

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

Shut-off dampers. Type AKK. For contaminated air PD AKK 1

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

CONSTANTFLOW Volume Flow Controllers

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

For installation into ductwork

VARYCONTROL VAV Dual Duct Terminal Boxes

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF

Type VSD35. Nominal length up to 1500 mm: one spigot

Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES

Ceiling swirl diffusers

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

RN-S: 80, 100, 125 RN: 80, 100, 125, 160, 200, 250, 315, 400 RN-FL: 100, 125, 160, 200, 250, 315, 400

Type AK FOR LOW-LEAKAGE SHUT-OFF. Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK

Homepage > Products > Control units > VARYCONTROL > VAV TERMINAL UNITS > Type TVR. Type TVR

Ceiling swirl diffusers

Pressure relief dampers

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Ceiling swirl diffusers

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Type AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK

Ceiling swirl diffusers with perforated face plate

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES

Ventilation grilles for installation into walls, sills or rectangular

Technical documentation

Mechanical mixing box MBM

Ventilation grilles for installation into walls, sills or rectangular

Homepage > Prodotti > Unità di regolazione > Regolazione di flussi costanti CONSTANTFLOW > KVS- Regolatore di portata > Serie EN.

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

Type WG. External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS, AVAILABLE ALSO IN LARGE SIZES

Floor diffusers. The art of handling air. Type FB. In aluminium and plastic

series Silencers

THB - Perforated Ceiling Diffuser. Halton THB. Perforated Ceiling Diffuser

Type TVLK OPTIMISED FOR USE IN LABORATORIES AND ON FUME CUPBOARDS

5/9.2/EN/6. Volume Flow Limiter. Type VFL for insertion into air ducting. The art of handling air

Air Displacement Vent Units

TBV - Terminal Unit. Halton TBV. Terminal Unit

series RVV Variable flow rate controllers

DFA - Conical Ceiling Diffuser. Halton DFA. Conical Ceiling Diffuser

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser

SERENO

VAV Terminal Units SDS

TCM - Conical Ceiling Diffuser. Halton TCM. Conical Ceiling Diffuser

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM

[Y] Acoustic Splitters with spigot ends/aerodynamically shapped for energy saving (Pressure drop reduction 25% to 30%)

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser

Volume Flow Limiters Type VFL

Sound attenuators. Sound attenuators, Sound attenuating louvres. Sound attenuators. Rectangular sound attenuators DZ-2, DZ-3

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R

Control units. Simple. Precise. Efficient. Control units LVC, TZ-/TA-Silenzio and VFL

Circular Box Fans - DAISHO EC Range DAISHO EC 125. Features. Electrical Supply. Product Code. Sizes 125, 150, 200, 250, 315, 450, 630 and 1000.

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

DKR - Multi-nozzle Ceiling Diffuser. Halton DKR. Multi-nozzle Ceiling Diffuser

Extract-air grille with ATK plenum box

Waterside Fancoil Units

VAV TERMINAL BOXES TYPE: BA BT

Rectangular inlet air diffuser

1/8/EN/6. Floor Diffusers. Type FB. in aluminium and plastic

Type NAK. Gas-tight shut-off damper with pneumatic actuator

Waterside Fancoil Units

Sound attenuators, Sound attenuating louvres

2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

VAV controller. TROX Auranor Norge AS. Telephone Fax

Regulation and shut-off damper SPB and SPC

Transcription:

X X testregistrierung Circular silencers Type For the reduction of noise in circular ducts, galvanised sheet steel construction Circular silencers Type for the reduction of noise in the circular ducts of air conditioning systems Absorption material is non-combustible mineral wool with RAL quality mark, biosoluble and hence hygienically safe according to the German TRGS 905 (Technical Rules for Hazardous Substances) and EU directive 97/69/EC Mineral wool faced with non-woven glass fibre as protection against erosion due to airflow velocities up to 20 m/s Casing and perforated inner duct are galvanised sheet steel Variant with spigot has a groove for a lip seal, suitable for circular connecting ducts to EN 1506 or EN 13180 Insertion loss measured according to ISO 7235 Casing air leakage to EN 15727, class B Optional equipment and accessories With flanges on both ends With lip seals on both ends PD 1

General information Type Page General information 2 Technical data 3 Quick sizing 4 Specification text 6 Order code 7 Variants 8 Dimensions and weight 9 Installation details 13 Basic information and nomenclature 14 Application Application Circular silencers Type for the reduction of noise in the circular ducts of air conditioning systems For the reduction of air-regenerated noise of air terminal units such as LVC and TVR, and of mechanical self-powered controllers such as RN and VFC For the reduction of fan noise Can be used as cross talk silencer to reduce the transfer of noise through ducts between neighbouring rooms Special features Insertion loss measured according to ISO 7235 Absorption material is non-combustible Insulation thickness 50 or 100 s 100, 125, 160, 200, 250, 315, 400, 450, 500, 560, 630, 710, 800 For VAV terminal units and V controllers 100, 125, 160, 200, 250, 315, 400 Description Variants 050: Circular silencer with 50 insulation 100: Circular silencer with 100 insulation VF1: Circular silencer with flange on one end VF2: Circular silencer with flanges on both ends Parts and characteristics Casing Perforated inner tube Absorption material Accessories GE: Matching flange for one end GZ: Matching flanges for both ends VD2: With lip seals on both ends Construction features Circular casing Spigot suitable for circular ducts to EN 1506 or EN 13180 Spigot with groove for lip seal Operating pressure up to 1000 Pa Operating temperature up to 100 C Materials and surfaces Casing and perforated inner duct are galvanised sheet steel Lining is mineral wool Mineral wool To EN 13501, fire rating class A1, non- combustible RAL quality mark RAL-GZ 388 Biosoluble and hence hygienically safe according to the German TRGS 905 (Technical Rules for Hazardous Substances) and EU directive 97/69/EC Faced with glass fibre as protection against erosion through airflow velocities up to 20 m/s Inert to fungal and bacterial growth Standards and guidelines Insertion loss measured according to ISO 7235 Casing air leakage to EN 15727, class B Maintenance Maintenance-free as construction and materials are not subject to wear PD 2

Technical data s Operating pressure Operating temperature 100 800 1000 Pa max. 100 C max. PD 3

Quick sizing The stated differential pressures for circular silencers correspond to the values for smooth pipes. Deviations, if any, are of no practical relevance. For ductwork calculation, if the length of a circular silencer is included in the total length of the ductwork, no extra length must be added. 050 (insulation thickness 50 ), insertion loss 100 125 160 200 250 315 400 Nominal length Centre frequency f m [Hz] 63 125 250 500 1000 2000 4000 8000 500 3 5 8 14 23 30 18 13 1000 4 9 15 27 42 50 43 25 500 3 4 7 12 21 23 12 10 1000 4 7 12 23 38 42 29 20 500 2 3 6 10 18 17 8 8 1000 3 5 9 19 34 30 18 15 500 1 2 5 9 16 13 5 6 1000 2 4 8 16 31 22 12 11 500 1 2 4 8 14 10 3 4 1000 2 3 6 14 28 17 8 9 1500 2 4 8 19 39 23 13 12 500 1 1 3 7 12 7 2 3 1000 1 2 5 12 25 13 5 6 1500 2 3 7 17 35 17 9 9 500 1 1 3 6 11 6 1 2 1000 1 2 4 10 22 10 3 5 1500 1 2 6 14 31 13 6 7 D e Hz 100 (insulation thickness 100 ), insertion loss Nominal length Centre frequency f m [Hz] 63 125 250 500 1000 2000 4000 8000 100 500 4 9 12 18 35 33 26 14 1000 5 17 24 35 50 50 47 25 125 500 4 7 10 17 31 26 19 11 1000 5 14 21 32 48 44 33 20 160 500 3 6 9 15 28 20 13 8 1000 5 11 18 30 42 33 22 15 200 500 3 5 8 15 25 16 9 7 1000 4 9 16 28 38 26 16 12 500 2 4 7 14 21 13 6 5 250 1000 3 8 14 26 33 21 11 9 1500 4 11 21 37 41 27 15 12 500 2 3 6 13 18 10 4 4 315 1000 3 6 12 24 29 16 8 7 1500 3 9 18 34 35 21 10 9 500 1 3 6 12 17 8 3 3 400 1000 2 5 11 23 25 12 5 5 1500 3 7 16 32 31 16 7 7 450 1000 2 5 10 22 23 11 4 5 1500 2 6 15 31 29 14 6 6 500 1000 2 4 10 21 22 10 4 4 1500 2 6 14 30 27 13 5 6 560 1500 2 5 13 29 25 11 4 5 630 1500 2 5 12 28 23 10 4 4 710 1500 2 5 11 27 22 9 3 4 800 1500 2 4 11 26 20 8 2 3 D e Hz PD 4

Quick sizing, differential pressure 100 125 160 200 250 315 400 450 500 560 630 710 800 Nennlänge [] 500 1000 1500 p st l/s m³/h Pa 30 108 2 2 60 216 4 8 75 270 6 12 90 324 8 18 50 180 2 2 95 342 4 6 120 432 6 10 145 522 6 14 80 288 2 2 155 558 2 6 195 702 4 8 235 846 6 10 125 450 2 2 245 882 2 4 310 1116 4 6 370 1332 4 8 195 702 <2 <2 <2 385 1386 <2 4 4 485 1746 2 4 6 580 2088 4 6 8 310 1116 <2 <2 <2 615 2214 <2 2 4 770 2772 <2 4 4 925 3330 2 4 6 500 1800 <2 <2 <2 995 3582 <2 <2 2 1245 4482 <2 2 4 1495 5382 <2 4 4 630 2268 <2 <2 1260 4536 <2 <2 1575 5670 <2 4 1890 6804 2 4 780 2808 <2 <2 1560 5616 <2 2 1950 7020 2 2 2335 8406 2 4 980 3528 <2 1955 7038 <2 2445 8802 2 2935 10566 4 1240 4464 <2 2480 8928 <2 3095 11142 <2 3715 13374 <2 1575 5670 <2 3150 11340 <2 3935 14166 <2 4725 17010 <2 2000 7200 <2 4000 14400 <2 5000 18000 <2 6000 21600 <2 PD 5

Specification text This specification text describes the general properties of the product. Texts for variants can be generated with our Easy Product Finder design prograe. Circular silencers for air conditioning systems, rigid construction, available in 13 nominal sizes. Insertion loss measured according to ISO 7235. Casing with acoustic and thermal insulation. Various types of connection, suitable for circular ducts to EN 1506 or EN 13180. Casing air leakage to EN 15727, class B. Special features Insertion loss measured according to ISO 7235 Absorption material is non-combustible Insulation thickness 50 or 100 Materials and surfaces Casing and perforated inner duct are galvanised sheet steel Lining is mineral wool Mineral wool To EN 13501, fire rating class A1, non- combustible RAL quality mark RAL-GZ 388 Biosoluble and hence hygienically safe according to the German TRGS 905 (Technical Rules for Hazardous Substances) and EU directive 97/69/EC Faced with glass fibre as protection against erosion through airflow velocities up to 20 m/s Inert to fungal and bacterial growth Technical data s: 100 to 800 Operating pressure: 1000 Pa max. Operating temperature: 100 C max. Sizing data D [] H [] Insulation thickness [] [m³/h] D e at 250 Hz [db] Δp st [Pa] PD 6

Order code 050 / 315 1000 / GZ / VF2 Type Circular silencer Insulation thickness [] 050 50 100 100 [] 100 125 160 200 250 315 400 450 500 560 630 710 800 Order example: 100/315 1500/GZ/VF2 Insulation thickness Length Matching flange Type of connection Nominal length [] 500 1000 1500 Matching flange No entry: none GE on one end (only VF1) GZ on both ends (only VF2) Type of connection No entry: spigot VD2 Spigot with lip seal on both ends VF1 Flange on one end VF2 Flanges on both ends 100 315 1500 Both ends Flanges on both ends PD 7

Variants Variant Circular silencer for the reduction of noise Spigot /.../VF1 Variant Circular silencer for the reduction of noise Spigot on one end to make connections to the ducting With flange on one end to make a detachable connection to the ducting /.../VF2 Variant Circular silencer for the reduction of noise With flanges on both ends to make detachable connections to the ducting PD 8

Dimensions and weight The tables show the available nominal sizes 60 L₁ L ØD₃ ØD, dimensions -050-100 ØD 3 ØD 100 199 299 99 125 224 324 124 160 259 359 159 200 299 399 199 250 349 449 249 315 414 514 314 400 499 599 399 450 648 448 500 698 498 560 758 558 630 828 628 710 908 708 800 998 798, lengths Nominal length L L 1 500 500 380 1000 1000 880 1500 1500 1380 PD 9

Dimensions and weight, weights -050-100 500 1000 1500 500 1000 1500 m kg kg kg kg kg kg 100 4 7 6 11 125 5 9 7 13 160 70 12 9 16 200 7 13 9 17 250 9 16 22 11 20 29 315 12 20 28 14 25 35 400 15 25 34 18 30 42 450 33 46 500 36 52 560 55 630 62 710 68 800 76 /.../VF1 L ØD₂ 50 L₁ 60 ØD₁ ØD₃ ØD T n x Ø9.5 /.../VF1, dimensions -050-100 ØD 3 ØD ØD 1 ØD 2 n T 100 199 299 99 132 152 4 4 125 224 324 124 157 177 4 4 160 259 359 159 192 212 6 4 200 299 399 199 233 253 6 4 250 349 449 249 283 303 6 4 315 414 514 314 352 378 8 4 400 499 599 399 438 464 8 4 /.../VF1, lengths Nominal length L L 1 500 490 380 1000 990 880 1500 1490 1380 PD 10

Dimensions and weight /.../VF1, weights -050-100 500 1000 1500 500 1000 1500 m kg kg kg kg kg kg 100 4 7 6 11 125 5 9 7 13 160 8 13 10 17 200 8 14 10 18 250 10 17 23 12 21 30 315 13 21 29 15 26 36 400 16 26 35 19 31 43 450 34 47 500 38 54 560 57 630 64 710 71 800 79 /.../VF2 50 L L₁ ØD₂ ØD₁ ØD₃ ØD n x Ø9.5 T /.../VF2, dimensions -050-100 ØD 3 ØD ØD 1 ØD 2 n T 100 199 299 99 132 152 4 4 125 224 324 124 157 177 4 4 160 259 359 159 192 212 6 4 200 299 399 199 233 253 6 4 250 349 449 249 283 303 6 4 315 414 514 314 352 378 8 4 400 499 599 399 438 464 8 4 450 648 448 488 514 8 4 500 698 498 538 564 8 4 560 758 558 600 634 12 4 630 828 628 670 704 12 4 710 908 708 750 784 12 4 800 998 798 840 874 16 4 PD 11

Dimensions and weight /.../VF2, lengths Nominal length L L 1 500 480 380 1000 980 880 1500 1480 1380 /.../VF2, weights -050-100 500 1000 1500 500 1000 1500 m kg kg kg kg kg kg 100 4 7 6 11 125 6 10 8 14 160 8 13 10 17 200 8 14 10 18 250 10 17 23 12 21 30 315 14 22 30 16 27 37 400 18 28 37 21 33 45 450 36 49 500 39 55 560 59 630 67 710 73 800 82 PD 12

Installation details Installation and coissioning Any installation orientation Installation in ducts outside of closed rooms requires sufficient protection against the effects of weather PD 13

Basic information and nomenclature Principal dimensions ØD [] Outer diameter of the spigot ØD₃ [] Outer diameter of circular silencers L [] Length of attenuator/silencer including spigot (in airflow direction) L₁ [] Length of acoustic cladding and acoustically effective length B [] Attenuator width and duct width (upright splitters) H [] Attenuator height and duct height (upright splitters) T [] Splitter thickness S [] Airway width n [ ] Number of flange screw holes m [kg] Weight Nomenclature f m [Hz] Octave band centre frequency L WA [db(a)] A-weighted sound power level of air-regenerated noise D e [db] Insertion loss [m³/h] and [l/s] Volume flow rate Δp st [Pa] Static differential pressure All sound power levels are based on 1 pw. All values were measured in a TROX lab and to EN ISO 7235. Intermediate values may be achieved by interpolation. Lab measurements exceeding 50 db are indicated as 50 db, in line with coon practice. PD 14