Document No D1 Revised December Atlantic Ultraviolet Corporation

Similar documents
Owner s Manual. Installation, Operation & Maintenance. Read and Follow All Safety Instructions. Save These Instructions. Model TM36-2.

Owner s Manual. Installation, Operation & Maintenance. Read and Follow All Safety Instructions. Save These Instructions. Model TM36-2.

Document No B6 Revised December Atlantic Ultraviolet Corporation

Installation Manual Stand-Alone Dispenser Pan Sensor

MINISTICK TM UV Germicidal Ultraviolet Light

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

007 Tank Monitor. WARNING Never use with gasoline or highly flammable liquids.

Installer s Manual. PCO/UV N-Duct Model

INSTALLATION & OWNER'S MANUAL

DWS404 DWS524 DWS654 DWS684 DWS694. DWS SERIES INSTALLATION/OWNER'S MANUAL Car Audio Speakers

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995

Helios. 24 Light 240 Volt Controller. PRODUCT # Instruction Manual.

LIGHTSTICK / LIGHTSTICK PLUS Germicidal Ultraviolet Light

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

Models DP10 & DP20 Series Low Voltage Disconnects User s Manual Rev. 1.1 October 31, 2007

II DISTRIBUTION & SUBSTATION TYPE C

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

HR-20P Pneumatically Controlled Pressure Regulator

INSTALLATION & OPERATING INSTRUCTIONS: REVOLUTION SPINEBOARD ATTACHMENT WARNING

Plus SABRE LIGHTBARS

INSTALLATION INSTRUCTIONS For Model 855 Wolo Express TM

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

Safety, Installation and Service Manual Models 1952, 1953 & 1972

XPC-EBP64 External Battery Pack User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Tiller Lock Assembly

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

Adjustable Angled Incline Conveyor Owners Manual with Operating Instructions

DUAL WIDEBAND AIR/FUEL RATIO GAUGE Product Numbers: GS-W702W_Dual, GS-C702W_Dual, GS-T702W_Dual

VANGUARD A EZ INSTALL OPERATOR S MANUAL

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

TS69 TS65 TS55 TS45 TS5768 TS SERIES INSTALLATION/OWNER'S MANUAL

TC26-B Vehicle Sensor

7-ASC / 8-ASC / 9-ASC

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

Switch-Pak. AU13, AV13 & AZ13 Series Owner s Manual. w/ Compact Relay Controller

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

BroadBand PowerShield. 20 AHr Battery. User Manual

JET METER INSTRUCTIONS

TYPE F-YRD. Operator s Manual

gamma uv Aquarium Ultraviolet Sterilizers

Users Guide for Ac-sync

C1XP Series. Models: C1XP01-115AC C1XP03-115AC C1XP03-D240AC USER MANUAL

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

COMPRESSED AIR LOADER MODEL: AL-1

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Submersible Pond Pump with UV 800 Gallons Per Hour

RF6 / RF10 / RF18 Installation Instructions

PART NUMBER: F-706RLSS REVOLUTION LIFT: SLING-SEAT OPTION

Please read all of the installation instructions carefully before installing the product. Improper installation will void manufacturer s warranty.

StormPro BA Series Sump Pump

SUNC3000 / Item #40885

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS

Installation and Operation Guide

i n s t r u c t i o n m a n u a l

AXS609 AXS612 AXS514 AXS SERIES. INSTALLATION/OWNER'S MANUAL Car Audio

Pump Installation and Service Manual HRS Hydromatic Retractable System

User Guide IGD Series

SPECIFICATIONS CONTENTS: Specifications Warning Information. Operating Instructions Preventative Maintenance and Troubleshooting

Firstmate Installation Manual and User's Guide May, 2003

Installation Instructions. Fog Lights. The lamps get very hot when they have been in use. Do not touch them as they may cause burns.

BP1204 INSTALLATION/OWNER'S MANUAL

Installation Power Management Unit Battery Cables and Battery Harness

Model Combustible Gas Sample Draw Detector Head Operator s Manual

ULTRAWARMER HOLDING STATION INSTALLATION & OPERATIONS MANUAL

Model Combustible Gas Sample Draw Detector Head Operator s Manual

Model 8309WC Barrier Free Shower & Eye/Face Wash

DM1016S INSTALLATION/OWNER'S MANUAL 10" Marine DVC Subwoofer

Installation / Operation Instructions Sunnex ORION Series Exam Lights

CTFRP Series Power Supplies

Heavy Duty Four Wheeled Walker

Level Alert Model Multi-Switch Liquid Level Sensor. Assembly and Installation Instructions

PVI 60KW, PVI 82KW, PVI 95KW

Please activate my limited warranty for WAGAN Corp.

Broadband PowerShield. CP27U Models. User Manual

HIGH VOLTAGE DIGITAL AMMETER

FIXED DEPTH INSERTION METER INSTRUCTIONS

UV DISINFECTION UNIT MODEL 3G

Ratio Feeder DB & DD Series Injectors

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

Model 8309WC Barrier Free Shower & Eye/Face Wash

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

2SHE Series Direct-Drive Shutter Fans

SOLAR DASH CHARGING SYSTEM USER GUIDE

HARDWARE KIT INSTALLATION GLOVES

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

Pressure Roller with 24-inch Fixed Extension - For application of architectural paints and coatings -

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

Owner s Manual. Installation, Operation & Maintenance Read and Follow All Safety Instructions. Save These Instructions. Ballast 230v 50/60Hz

Model C230 Pump Controller

Tissue Master. User Manual

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

Updated: October 2012

EchoPod. Technical Support. Model: DL14-(XX) Quick Start

INSTALLATION/OWNERS MANUAL

Table of Contents. Page 2. midlandusa.com. Model PPG100

APCO CSV-1600 SURGE CHECK VALVE

Transcription:

375 Marcus Boulevard Hauppauge, NY 11788 USA 631.273.0500 Fax: 631.273.0771 e-mail: info@ultraviolet.com Extensive Product Information Available at: www.ultraviolet.com Document No. 98-1138D1 Revised December 2009 2003-2009 Atlantic Ultraviolet Corporation

TABLE OF CONTENTS SAFETY INSTRUCTIONS...3 PRODUCT APPLICATION...3 INSTALLATION...3 CONVENTIONAL INSTALLATION...3-4 GUARDIAN TM CONNECTIONS FOR SANITRON TM MODELS S5,000 AND LARGER...4 ANALOG GUARDIAN TM...4 DIGITAL GUARDIAN TM...4 TRIP SET POINT...4 OUTPUTS...5 OUTPUT SOCKETS...5 DIGITAL GUARDIAN TM MODULAR REMOTE OPTIONS...5 4-20MAOUTPUT...6 DRY CONTACTS...6 REMOTE LOW-VOLTAGE AUDIO ALARM...6 DC MODELS...6 TROUBLESHOOTING...7 LOW INTENSITY READINGS...7 FUSE...7 TECHNICAL SPECIFICATIONS...7 ACCESSORIES...8 WARRANTY...8 ASSISTANCE...8 These instructions generally describe the installation and operation of the GUARDIAN TM Ultraviolet Monitor. Questions that are not specifically answered by these instructions should be directed to the Factory. Atlantic Ultraviolet Corporation takes all possible precautions when packaging equipment to prevent damage. Carefully inspect and report all damage upon receipt of product. Do not install damaged equipment. Follow all instructions on all labels and tags. Carefully inspect all packing materials before discarding to prevent the loss of accessories, mounting hardware, spare parts or instructions. 2 The information and recommendations contained in this publication are based upon data collected by the Atlantic Ultraviolet Corporation and are believed to be correct. However, no guarantee or warranty of any kind, expressed or implied, is made with respect to the information contained herein. Specifications and information are subject to change without notice.

SAFETY INSTRUCTIONS 1. Read and follow ALL safety instructions. 2. Intended for indoor use only. 3. The GUARDIAN TM Ultraviolet Monitor should be protected from harsh environments, high humidity, and temperature extremes. 4. The GUARDIAN TM Ultraviolet Monitor housing is not waterproof. Serious damage can occur if internal electronics come into contact with water. 5. Do not alter the construction or design. 6. Do not use this monitor for other than its intended purpose, as described in this manual. 7. Do not operate the monitor if the power cord and/or plug are damaged, or if any other damage to the monitor is visible or suspected. 8.! CAUTION: Do not operate without proper electrical ground. 9. Utility power supplied, to the monitor, MUST match power requirements listed on the monitor label. 10.! WARNING: Always disconnect power, to the monitor and unplug, before performing any service or maintenance. 11. SAVE THESE INSTRUCTIONS. PRODUCT APPLICATION The GUARDIAN TM Ultraviolet Monitor visually indicates the level of germicidal ultraviolet energy that penetrates the quartz sleeve and water within the purifier. The monitor will detect reduction of ultraviolet levels due to: Fouling or deposits on the quartz sleeve. Poor ultraviolet transmission through the water. Color, turbidity, and organic or other impurities in the water can reduce or interfere with the transmission of ultraviolet rays. Lamp outage, component or power failure. Depreciation of the lamp output due to usage or other cause (lamp output gradually depreciates with use). GUARDIAN TM monitors are available with either an analog or digital intensity meter. All GUARDIAN TM monitors provide output sockets for the operation of an optional solenoid valve or time delay/solenoid valve combination and optional audio alarm. The digital GUARDIAN TM can provide a programmed 2-minute time delay for solenoid valve operation. This feature is disabled when shipped. For the instructions to enable the time delay feature, contact the factory. The digital GUARDIAN TM provides outputs for remote monitoring of the water purifier's operation. The outputs; 4-20mA Output: Provides current for remote display of ultraviolet intensity. Dry Contacts: Provides contacts for remote indication of ultraviolet trip levels. 12v DC Output: Provides power for a low-voltage audio alarm. INSTALLATION CONVENTIONAL INSTALLATION Each monitor is calibrated with its accompanying sensor probe. The serial number engraved on the sensor probe must match the serial number of the monitor. If installing more than one monitor, DO NOT interchange sensor probes. Newer GUARDIAN TM monitors have been calibrated for use with updated sensor probes and cannot be used with earlier model probes without factory recalibration. Verify that the operating voltage and purifier model number indicated on the monitor are the same as indicated on the water purifier. Older model water purifiers may require a reducing bushing to properly mount the newer sensor probes. If you are unsure whether the reducing bushing is required, contact the factory. 1. Unplug the water purifier from electrical outlet. 2. If the purifier has been in service, shut off water supply to the purifier via the inlet and outlet shut off valves. 3. Remove the translucent sight port plug from the center, sight port fitting of the chamber. 3

INSTALLATION CONVENTIONAL INSTALLATION CONT.! CAUTION: The quartz rod protrudes out past the probe cap, be careful not to strike rod against fitting when installing the probe. 4. Insert probe into the center, sight port fitting of the purifier chamber and tighten securely. The use of thread sealing tape or sealing compounds, and hand tools, for tightening, are no longer required. 5. Slowly restore water supply to the water purifier, pressurize (keeping the outlet valve closed), and check for leaks. Once it is determined that there are no leaks, the inlet valve can be fully opened. 6. Seat the monitor on top of the sensor probe; position the monitor as desired, and secure by tightening the set screws in the aluminum collar. 7. Any optional accessories such as; audio alarms, solenoid valves or cabling should be connected to the appropriate sockets or to the appropriate terminals (DC version) before connecting the monitor to power. 8. With the monitor switch in the OFF position, plug the monitor into a convenient electrical outlet, or if the monitor is a DC version, connect power terminals to an appropriate DC power source. 9. Plug the water purifier into electrical outlet and restore power. Allow purifier to warm up for approximately 10-minutes. Warm up period allows germicidal lamp to reach full output. 10. Switch the monitor ON. The solenoid valve (if installed) should open and the NORMAL indicator light should come on. The analog meter should read between.3 and 1.00, or the digital meter should read between 30 and 100. 11. Open outlet valve. If for any reason the ultraviolet intensity falls to an inadequate level, the display will indicate in the trip area, (generally less than.3 on the analog meter or 30 on the digital), the LOW indicator light will light, the optional audio alarm (if installed) will sound, and the optional solenoid valve (if installed) will close. GUARDIAN TM CONNECTIONS FOR SANITRON TM MODELS S5,000 AND LARGER ANALOG GUARDIAN TM On SANITRON TM models S5,000 and larger, with solenoid valves installed, two ultraviolet monitors can be operated in series with each pair of purifiers connected in series. If solenoid valves are not installed, see Conventional Installation for installation and connection instructions. 1. Install sensor probe and monitor. See Conventional Installation for installation instructions; connect as follows. 2. Plug the first monitor into an electrical outlet. 3. Plug the second monitor into the SOLENOID VALVE socket of the first monitor. 4. Plug the solenoid valve into the remaining SOLENOID VALVE socket. Note: In operation, the solenoid valve will close if the ultraviolet intensity in either purifier falls below normal operating limits. An audio alarm should be plugged into each monitor. DIGITAL GUARDIAN TM On SanitrontM models S5,000 and larger, with solenoid valves installed, multiple monitors may be connected to operate together to power a solenoid valve when both monitors are reading NORMAL and to operate external warnings when any monitor's readings are LOW. If solenoid valves are not installed, and the audio alarm outputs are not shared, see Conventional Installation for installation and connection instructions. To link the output signals of two or more digital guardiantm monitors, consult our technical support staff. TRIP SET POINT 4 The GUARDIAN TM is calibrated at the factory to the ultraviolet output of the lamp, and the water purifier for which the monitor will be used. The sensitivity should not be changed, except where necessary for wastewater applications, contact the factory with specific requirements. On the digital GUARDIAN TM, two push buttons on the back of the monitor allow the user to display or adjust the trip set point. (The point at which the indicator lights change from red to green, or vice versa, and the relay contacts change over.) The digital display on the front of the monitor will show the relative ultraviolet intensity (0 to 100%). After pushing either button for less than a second, the display will show the trip set point before returning to the normal display. For wastewater applications, the operator may wish to adjust the trip set point. Pressing and holding the UP button allows the operator to increase the trip set point, pushing and holding the DOWN button allows the operator to decrease the trip set point.

OUTPUTS OUTPUT SOCKETS TM Every GUARDIAN TM monitor, both the analog and digital versions, comes equipped with two 3-pin convenience sockets. These sockets provide output power for an optional solenoid valve or time delay/solenoid valve combination and remote audio alarm. The combined load on the AUDIO ALARM and SOLENOID VALVE output sockets (120v and 220v AC versions) should not exceed 3 Amps. DIGITAL GUARDIAN TM MODULAR REMOTE OPTIONS The digital GUARDIAN TM Ultraviolet Monitor is capable of supplying outputs for remote monitoring of the water purifier's operation. An RJ45 modular jack, located on the back of the monitor, is provided to access these outputs. An RJ45 modular cable and RJ45 modular jack adaptor are required to interconnect between the GUARDIAN TM and the remote monitoring devices. The RJ45 modular cable and modular jack adaptor are not supplied and can be obtained from the factory, see Accessories or contact the factory with specific requirements. Table 1 - Digital GUARDIAN TM Modular Remote Options Connection Wire Modular Jack Modular Network No. Application Wire Color Cable Wire Color 1 Trip Input - Master Trip Input Blue White/Orange 2 Dry Contact - Normally Closed (NC) Orange Orange (UV "NORMAL") 3 Output Current / Low-voltage Audio Alarm - Black White/Green Common Negative 4 Dry Contact - Common Red Blue 5 Output Current - 4-20mA (+) Green White/Blue 6 Dry Contact - Normally Open (NO) Yellow Green (UV "NORMAL") 7 Low-Voltage Audio Alarm - +12v (UV "NORMAL") Brown White/Brown 8 Low-Voltage Audio Alarm - +12v (UV "LOW") White Brown UV NORMAL : Ultraviolet lamp operating, ultraviolet intensity above trip set point and NORMAL indicator light, lit. UV LOW : Ultraviolet lamp may or may not be operating, ultraviolet intensity below trip set point and LOW indicator light, lit. Figure 1 - Digital GUARDIAN TM Modular Remote Options Connection 5

Figure 2 - Monitor Back (Analog GUARDIAN TM ) Figure 3 - Monitor Back (Digital GUARDIAN TM ) 4-20MA OUTPUT The 4-20mA output supplies an output corresponding to the intensity meter, converted to a current between 4 and 20mA. The output is unaffected by reasonable line resistances, but the output must be displayed by a PLC, computer, or 4-20mA meter which can interpret the signal. A 4mA output will be displayed as 0% ultraviolet intensity and 20mA will be displayed as 100%. DRY CONTACTS The Dry Contact output provides a Single Pole Double Throw (SPDT) output corresponding to the NORMAL or LOW intensity of the germicidal lamp. The contacts are rated at 50v 100mA maximum. Common will connect to Normally Closed (NC) when the display value is above the trip set point and the green NORMAL indicator light is lit. Common will connect to Normally Open (NO) when the display value is below the trip set point and the red LOW indicator light is lit. REMOTE LOW-VOLTAGE AUDIO ALARM Although the AUDIO ALARM output socket provides power for a remote audio alarm, these alarms must be either 120v AC or 220v AC, depending on the AC voltage supplying the monitor. A 12v DC 50mA maximum output is provided to power a remote low-voltage audio alarm. An optional Single Pole Double Throw (SPDT) switch can be installed with the low-voltage audio alarm in a way that allows the audio alarm to be silenced during an alarm condition. The audio alarm will sound again when the normal condition is restored, this prevents the alarm from being accidentally disabled by the switch. DC MODELS The operating power for a D.C. monitor may be supplied from a car, boat or truck battery. A relay, within the monitor can supply output voltages to power a solenoid, when the monitor reads a normal condition, and an alarm when the meter reads insufficient UV intensity. The voltage output for the solenoid or alarm is provided by the D.C. power input to the monitor. If it is required to have an isolated pair of contacts, the jumper may be removed between terminals 3 and 4, then the relay common contact is pin 4. Terminal 5 will be normally open and 7 will be normally closed when the meter is indicating a normal condition. 6

TROUBLESHOOTING "LOW" INTENSITY READINGS If, during the normal operation of the purifier, the intensity readings fall to an inadequate LOW level, take the following steps: 1. Clean the quartz sleeve; see the Owner's Manual supplied with the water purifier for the proper cleaning method, and note whether the intensity readings improve. NOTE: On water purifiers not equipped with a wiper mechanism, removal of the quartz sleeve is required for cleaning. 2. If after cleaning the quartz sleeve, there is no significant improvement in the intensity readings, it may be necessary to clean the quartz rod in the sensor probe, see the Owner's Manual supplied with the water purifier for the proper cleaning method.! WARNING: Germicidal ultraviolet rays are harmful to eyes and skin. DO NOT look directly at the germicidal lamp. 3. Remove monitor and sensor probe. Place a small piece of common window glass over the sight port fitting and reapply power to the water purifier. Germicidal ultraviolet rays are absorbed by window glass and will not penetrate the glass. 4. Observe the condition of the lamp, quartz sleeve and water. The quartz sleeve should be clear and clean. The germicidal lamp should operate steadily, without flicker. The water in the purifier should be clear. 5. If the conditions of the lamp, quartz sleeve, and water are as stated, re-install sensor probe and monitor. Drain the water from the purifier, reapply power to the purifier and monitor, and check the readings with no water in the purifier. 6. If readings are NORMAL, (1.0 on the analog version or 100 on the digital) with no water in the purifier, then there has been a change in water quality. Have water tested to confirm that it does not exceed maximum recommended concentration levels for use with the purifier. See the Owner's Manual supplied with the water purifier for the recommended concentration levels. 7. If you are still unable to correct the problem, consult our technical support staff. FUSE A 5A, 5mm x 20mm, fuse protects the monitor from damage in the event that the audio alarm or solenoid valve outputs are short-circuited. The fuse can only be replaced by opening the case. NOTE: Opening the case may void the warranty, and should only be attempted after contacting our technical support staff. TECHNICAL SPECIFICATIONS Table 2- Technical Specifications General Specifications Voltage: 120v +/-10% Frequency: 50/60Hz.(all models) Output Current: 3 Amps max.(all sockets) Case Dimensions: 6" wide x 4" high x 3 ¾" deep Case Material: UL Rated ABS Plastic Weight: 2 lbs (approximate) GUARDIAN TM Analog Version GUARDIAN TM Digital Version Current: 0.015A 0.025A (120v), 0.0125A (220v) (No load) Wattage: 1.8 Watts 3 Watts (No load) 4-20mA Output: NA Sourced from GUARDIAN TM Dry contact rating: NA 50v AC or DC. 100mA Low-Voltage Audio Alarm: NA 12v DC 50mA 7

ACCESSORIES USER ASSISTANCE Table 3 - Accessories Part Number Description 25-0844A Cable Assembly: Remote Output, Modular 30-0122 Modular Jack: 8-Pin Surface Mount 35-0239 Cable Assembly: Coax BNC Male Connectors 50' 30-0100 Remote Monitor Extension Kit: 50' Cable including Connector 30-1243A Audio Alarm: 120v 50/60Hz 30-1244A Audio Alarm: 220v 50/60Hz 30-0077 Audio Alarm: 12v DC 30-1369B Time Delay: 120v 50/60Hz 2-Minute 30-0012B Time Delay: 220v 50/60Hz 2-Minute Please read and become familiar with the contents of this manual before installing or using the GUARDIAN TM Ultraviolet Monitor. If after reading the manual you still have questions, or concerns, regarding the installation or use of the GUARDIAN TM, contact our offices, weekdays between 8:30 am and 5:00 pm Eastern time, at: Atlantic Ultraviolet Corporation 375 Marcus Boulevard Hauppauge, New York, 11788 Tel: 631.273.0500 Fax: 631.273.0771 E-mail: info@ultraviolet.com Website: www.ultraviolet.com For your convenience, record the following information below. The model and serial number can be found on a label located on the GUARDIAN TM Ultraviolet Monitor. Keep this manual, along with proof of purchase handy when contacting our offices. Purchased From: Model: Date: Serial No.: WARRANTY We warrant that this product will be free from defects in material and workmanship for a period of one year from the date of shipment thereof or the product s total rated life, whichever first occurs. Within the warranty period we shall repair or replace such products, which are returned to us with shipping charges prepaid, and which are determined by us to be defective. This warranty will not apply to any product, which has been subjected to misuse, negligence, or accident; or misapplied; or modified; or repaired by unauthorized persons; or improperly installed. The Buyer shall inspect the product promptly after receipt and shall notify us at our main office in writing of claims, including claims of breach of warranty, within thirty (30) days after the Buyer discovers or should have discovered the facts upon which the claim is based. Failure of the Buyer to give written notice of a claim within the time period shall be deemed to be a waiver of such claim. The provisions of the above warranty are our sole obligation and exclude all other remedies or warranties, expressed or implied, including warranties of merchantability and fitness for a particular purpose, whether or not purposes or specifications are described herein. We further disclaim any responsibility whatsoever to the customer, or to any person, for injury to person, damage to, or loss of property or value caused by any product which has been subjected to misuse, negligence, accident; or modified or repaired by unauthorized persons; or improperly installed. Under no circumstances shall the Company be liable for any incidental, consequential or special damages, losses or expenses arising from the contract for this product, or in connection with the use of, or inability to use, our product for any purpose whatsoever. 8