Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

Cutler-Hammer. Molded Case Circuit Breakers Amperes. Product Selection January 2001 Vol. 1, Ref. No ) J-Frame

Cutler-Hammer. Molded Case Circuit Breakers Amperes F-Frame. January 2001

Cutler-Hammer. January 2001

Switchboards Instant Service

Cutler-Hammer. Molded Case Circuit Breakers Amperes January J-Frame

Cutler-Hammer. Molded Case Circuit Breakers Amperes. -" Product Selection M-Frame

Molded Case Circuit Breakers Amperes LSIA. LSIG Catalog Number 3-Pole Standard Interrupting Capacity 600V AC Rated V AC 13,950.

Interrupting Capacity (Symmetrical Amperes) Volts ac (50/60 Hz) Y/ ,000 25,000. Frame Only E2L3600F

L-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W

Molded Case. Circuit Breakers. Molded Case Circuit Breakers Contents

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

Product Line Overview. The Most Logically Designed Contact Assembly

2.3. Molded Case Circuit Breakers. Contents

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

L-Frame. With Standard Line and. Standard Terminals Only. Catalog Number. Price U.S. $ LDB2300 LDB2350 LDB2400 LDB2450 LDB2500 LDB2600

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

Poles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Engine Generator Circuit Breakers

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

Technical Data and Specifications. Table UL 489/IEC Interrupting Capacity Ratings. cu I cs I cu I cs I cu I cs I cu I cs I cu I cs

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

SECTION PANELBOARDS

Lighting and Power Distribution Panelboards

2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

30 ma Ground Fault (Earth Leakage) Modules. Product Description

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

Series C, F-frame molded case circuit breaker, 15A, Two-pole, Thermal Magnetic Trip, FD Breaker

Modifications. Marine 50 C Ambient Calibration

Type MP-T Type MP-HT Type MP-MT

Features 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) RG H ZG E C

XT IEC Power Control Manual Motor Protectors

Application guide. Tmax Link OEM UL 891 Switchboard Program

NEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications

2.3. Molded Case Circuit Breakers. Contents. Internal Accessories. Series C. Product Overview. Description

Series KTU7 UL489 Molded Case Circuit Breakers

Series C, F-frame molded case circuit breaker, 125A, Three-pole, Thermal magnetic trip. Thermal magnetic

Control Circuit Protection

Series L9 UL489 Miniature Circuit Breakers

CH120CAFPN 1P 20A 120 Combo Arc Fault PN Breaker

Cutler-Hammer. Installation Instructions for the Digitrip OPTIM Pole Trip Unit Installation and Operation with L-Frame Series C Circuit Breakers

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

25.4. Molded Case Circuit Breakers. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

MOLDED CASE CIRCUIT BREAKER BASICS. David Castor, P.E.

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Product Selection 3-Pole Contactors

A302DN.40/.63A Thermal Current Motor Starter

Series KTU7 UL489 Molded Case Circuit Breakers

Modifications. Marine 50 C Ambient Calibration

Product Guide. QR Circuit Breaker. usa.siemens.com/circuitbreakers

Series L9 UL-489 Miniature Circuit Breakers

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

' '!' D Model, 70 to 250 Amperes. W Model, 63 to 250 Amperes. www. ElectricalPartManuals. com

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

FACTORY SEALED CIRCUIT BREAKER PANELBOARDS

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System

1489-M Circuit Breakers

F-Frame. January 2001 Vol. 1, Ref. No. [0586] Discount Symbol... CB-2. For more information contact Cutler-Hammer at:

Section 3: Molded Case Circuit Breakers

Molded Case Circuit Breakers

Installation Instructions for JDB, JD, HJD, JDC, JW HJW, JWC Circuit Breakers and Molded Case Switches

Molded Case Circuit Breakers

MOLDED CASE CIRCUIT BREAKERS

22.000A IR. Catalog Number. Price $

Q and M-Frame Circuit Breaker Instruction Leaflet for Installation and Operation for Thermal Magnetic Trip Units

PANELBOARDS C1/C2 SECTION 6

Molded Case Circuit Breakers

Products :: Circuit Protection :: Thermal Circuit Breakers

Molded Case Circuit Breakers

Underwriters Laboratories Inc. Marking Guide. Molded Case Circuit Breakers. 600 Volts or Less April 2002

VL Circuit Breaker Features & Benefits. powerful ideas RELIABLE SOLUTIONS

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

Molded Case Circuit Breakers

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Supplementary Protectors. Circuit Breakers & Circuit Breakers & Supplementary Protectors Contents

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

File E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany

Product Line Overview. The Most Logically Designed Contact Assembly

THQL1120AF2 THQL1120AF2 Arc Fault BRKR

Circuit Breakers Naval Shipboard Use

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

Overload Relay Heater Tables

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

3. Coils shall be of molded construction

PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers

PowerPact B. Molded case circuit breakers and switches from A

Series G Moulded Case Circuit Breakers A for IEC & NEMA Applications

A. Submit manufacturer's literature and technical data before starting work.

Laser Service Factory-assembled Panelboards

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Molded Case Circuit Breakers

Transcription:

Cutler-Hammer Vol.

-2 Product Line Overview Vol. 1, Ref. No. [0468] Product Line Description Cutler-Hammer Molded Case s are designed to provide circuit protection for low voltage distribution systems. They are described by NEMA as,... a device for closing and interrupting a circuit between separable contacts under both normal and abnormal conditions, and furthermore as,... a breaker assembled as an integral unit in a supporting and enclosing housing of insulating material. The NEC describes them as, A device designed to open and close a circuit by non-automatic means, and to open the circuit automatically on a predetermined overload of current, without injury to itself when properly applied within its rating. So designed, Cutler-Hammer circuit breakers protect conductors against overloads and conductors and connected apparatus, such as motors and motor starters, against short circuits. In low voltage distribution systems, there are many varied applications of molded case circuit breakers. Cutler-Hammer offers the most comprehensive family of molded case circuit breakers in the industry. This family of circuit breakers includes: Thermal Magnetic Trip s Electronic rms Trip s Molded Case Switches Motor Protectors Current Limiting s Special Application s World s Special Calibration Special non-ul-listed calibrations are available for certain ambient temperatures other than 40 C and for frequencies other than 50/60 Hz or DC. Reduced interrupting ratings will apply for 400 Hz applications. Maximum thermal calibration is limited to 135A at 400 Hz. H01 400 Hz 20% Moisture-Fungus Treatment All circuit breaker cases are molded from glass-polyester which does not support the growth of fungus. Any parts which are susceptible to the growth of fungus will require special treatment. J01 Fungus Treated Freeze-Tested s The circuit breakers may be ordered with freeze testing. This option uses special lubrication and mechanical operation is verified at -40 C. F01 Freeze Tested Marine Applications F-Frame circuit breakers can be supplied to meet the following marine specifications: U.S. Coast Guard CFR 46 ABS American Bureau of Shipping IEEE 45 These specifications generally require molded case circuit breakers to be supplied with 50 C ambient calibration, special nameplating, and plug-in adapter kits. When plug-in adapter kits are used, no terminals need be supplied. breakers can also be supplied to meet UL489 Supplement SA (Marine Use) and UL489 Supplement SB (Naval Use). UL489 Supplement SA applies to vessels over feet in length. Requirements include 40 C ambient calibration, special labeling, and no use of aluminum conductors or terminals. H08 Marine UL 489 Supplement SB requires 50 C ambient calibration, vibration testings, special nameplating and no use of aluminum conductors or terminals. H09 Naval $325. + 20% 20% 10% 10% Standards and Certifications Molded case circuit breakers are designed to conform with the following standards: Underwriters Laboratories, Inc., Standard UL489, Molded Case s and Enclosures National Electrical Manufacturers Association Standards Publication No. AB1-1993, Molded Case s Australian Standard AS 2184, Molded Case s British Standards Institution Standard BS 4752: Part 1, Switchgear and Control Gear Part 1: s Canadian Standards Association Standard C22.2 No. 5, Service Entrance and Branch s International Electrotechnical Commission Recommendations IEC 157-1, s Japanese T-Mark Standard Molded Case s South African Bureau of Standards, Standard SABS 156, Standard Specification for Molded Case s Swiss Electro-Technical Association Standard SEV 157-1, Safety Regulations for s Union Technique de l Electricite Standard NF C 63-0, Low Voltage Switchgear and Control Gear Requirements Verband Deutscher Elektrotechniker (Association of German Electrical Engineers) Standard VDE 0660, Low Voltage Switchgear and Control Gear, s Conformance with these standards satisfies most local and international codes, assuming user acceptability and simplified application. Molded case circuit breakers equal or exceed Federal Specification Classification W-C-375b requirements for the particular class associated with the circuit breaker frame being considered. 50 C Calibration Add suffix V to for complete breaker, listed above, when ordering listed ampere ratings for breakers to be used in 50 C ambients. Note: For further information, see, CD-ROM SA.74A.01.T.E.

-6 15 100 Amperes G-Frame Vol. 1, Ref. No. [0472] Contents Description Page Product Description......... -6 Technical Data and Specifications......... -6 Product Selection........... -7 GD Thermal-Magnetic s with Non-interchangeable Trip Units................ -8 GD Molded Case Switches................. -8 GB, GHB and HGHB Bolt-On Panelboard s........... -9 GHBGFEP Bolt-On Panelboard Ground Fault Protectors.......... -10 s GC, GHC and HGHC s........... -11 GHCGFEP Ground Fault Protectors.......... - Special Purpose GC and GHC s....... -13 Product Description All two- and three-pole circuit breakers are of the common trip type. On all 3-phase Delta (240V) Grounded B phase applications, refer to Cutler-Hammer. Single-pole circuit breakers, 15 and 20 amperes. Switching duty rated (SWD) for fluorescent lighting applications. All G-Frame circuit breakers are suitable for reverse feed use. HACR rated. Technical Data and Specifications Interrupting Capacity Ratings Table -2. UL489 Interrupting Capacity Ratings GD 2 3 Two poles of 3-pole circuit breaker. Time constant is 8 milliseconds minimum. Table -3. UL489 Interrupting Capacity Ratings (Continued) GB 1 GQ GHB 1 HGHC 1 25 15 through 70A breakers only. Terminal s Interrupting Capacity (Symmetrical Amperes) (ka) AC (50/60 Hz) DC 0 240 277 480 5/250 250 For line and load-side. Terminals are UL listed as suitable for wire type and size given below. Table -4. Terminal s Optional GD Only 15 100 Pressure (Steel Body) Slotted Cu 3 Not UL listed sizes. Interrupting Capacity (Symmetrical Amperes) (ka) AC (50/60 Hz) DC 0 240 277 480Y/277 5 5/250 22 10 HGHB 1 25 GC 1 GHC 1 Amperes Standard 15 20 25 100 Terminal Material Clamp (Plated Steel) Pressure (Aluminum Body) Screw Head Slotted Slotted Wire Cu/Al Cu/Al AWG Wire Range 10 10 1/0 10 Metric Wire Range (mm 2 ) 2.5 4 4 50

Vol. 1, Ref. No. [0473] 15 100 Amperes G-Frame Product Selection This information is presented only as an aid to understanding s. It is not to be used to build s for circuit breakers or trip units. Table -5. /Frame ing System G D 3 1 0 0 K GD GB GHB GC GHC GQ 1 = 1 Pole 2 = 2 Poles 3 = 3 Poles Trip Amperes 015 020 024 030 035 040 045 050 060 070 080 090 100 K = Molded Case Switch D = Ring Terminals C = Steel Collars V = 50 C J01 = Fungus Proofed R01 = Shock Tested F01 = Freeze Tester HID = High Intensity Discharge

-170 Internal Accessories Shunt Trip Vol. 1, Ref. No. [0636] Table -335. G-Frame Shunt Trip (LH 3-Pole only) 0 240 24 24 Frequency Amp 50/60 Hz 50/60 Hz DC DC 60 Hz 1.1 2.1 2.8 5.7 1373D62G01 1373D62G02 1373D62G15 1373D62G16 1373D62G20 S1 S2 S3 S4 S7 Note: G-Frame circuit breakers are factory sealed. Underwriters Laboratories requires that internal accessories be installed at the factory. Internal accessories are UL listed for factory installation under E7819. Where local codes and standards permit and UL listing is not required, internal accessories can be field installed. Accessory installation should be done before the circuit breaker is mounted and connected. Note: Instruction Leaflet/FRED 15550 Table -336. E5 Shunt Trip Frequency Hz 60 110 240 380 600 50/60 Suitable for use in ground fault applications. Note: Instruction Leaflet/FRED 29C152 SNT060CPK SNT0CPK SNT480CPK Table -337. F-Frame Shunt Trip Voltage Rating Factory Mounted Field Mounted (AC Frequency = 50/60 Hz) Connection and Location Field Installation Kits 18-Inch (457.2 mm) Pigtail Leads Terminal Block Pigtail Leads Terminal Block Same Side Rear Opposite Side Same Side Left-Pole Mounting AC/DC Ratings 24V AC or DC 48 7V AC or 48 60V DC 208 380V AC or 110 7V DC 415 600V AC or 220 250V DC S01 S05 S09 S13 Right- or Neutral-Pole Mounting AC/DC Ratings 24V AC or DC 48 7V AC or 48 60V DC 208 380V AC or 110 7V DC 415 600V AC or 220 250V DC S17 S21 S25 S29 S02 S06 S10 S S18 S22 S26 S30 Not listed with Underwriters Laboratories, for field installation. Pigtail wire size: 18 AWG (0.82 mm 2 ). Standard pigtail lead exit location. 0V AC marked suitable for ground fault protection devices. Standard mounting location. Not for use on 4-pole circuit breakers. Note: Instruction Leaflet/FRED 29C0 S03 S07 S11 S15 S19 S23 S27 S31 S04 S08 S S16 S20 S24 S28 S32 SNT1LP03K SNT1LP08K SNT1LPK SNT1LP18K SNT1RP03K SNT1RP08K SNT1RPK SNT1RP18K SNT1LT03K SNT1LT08K SNT1LTK SNT1LT18K SNT1RT03K SNT1RT08K SNT1RTK SNT1RT18K Table -338. J250 Shunt Trip Frequency Hz 60 110 240 380 600 50/60 SNT060CPK SNT0CPK SNT480CPK Suitable for use in ground fault applications. Note: Instruction Leaflet/FRED 29C152 Discount Symbol........................ CB-2