Gas-actuated thermometer with switch contacts Stainless steel version Model 73

Similar documents
Gas-actuated thermometer with switch contacts Model 73, stainless steel version

Gas-actuated thermometer Model 73, stainless steel version

Gas Actuated Thermometers Stainless Steel Series, Model 73

Bourdon tube pressure gauge with switch contacts Stainless steel case Model PGS21, NS 100 and 160

Gas-actuated thermometer with switch contacts For sanitary applications, stainless steel version Model 74

Bimetal thermometer Model 52, industrial series

Absolute pressure gauge with switch contacts For the process industry, NS 100 and 160 Models , and

Gas-actuated thermometer Highly vibration resistant Model 75, stainless steel version

Differential pressure gauge with switch contacts For the process industry, all-metal media chamber Models DPGS43.100, DPGS43.160

Bimetal thermometer Model 52, industrial series

Differential pressure gauge with switch contacts For the process industry Models DPGS43HP.1x0, high overload safety up to 40, 100, 250 or 400 bar

Resistance thermometer with digital display Model TR75, battery operation

Bimetal thermometer with Pt100 electrical output signal Model 54, stainless steel version

k Applications Bourdon tube pressure gauge with switch contacts For the process industry, NS 100 and 160 Models PGS and PGS23.

Bimetal Thermometers Process Industry Series, Model 55

Bourdon tube pressure gauge with switch contacts Models PGS21.1x0, industrial series

Differential pressure gauge For the process industry Models , , high overload safety up to 40, 100 or 400 bar

Bourdon tube pressure gauge, copper alloy Panel mounting series Models and

Mini temperature switch Stainless steel switch enclosure Model TXS

Differential pressure gauge with output signal For the process industry, all-metal media chamber Models DPGT and DPGT43.160

Mechatronic pressure measurement. Applications. Special features. Description

Bourdon tube pressure gauge with switch contacts Models PGS23.1x0, stainless steel version

Bimetal Thermometers Model 54, Heavy Duty Series

Compact temperature switch Model TCS

Measuring insert for process resistance thermometer

Bourdon tube pressure gauges with switch contacts Models PGS23.1x0, stainless steel version

Differential pressure gauge with output signal With integrated working pressure indication (DELTA-trans) Model DPGT40

Surface thermocouple Model TC50

Bourdon Tube Pressure Gauges with Switch Contacts Models /160, Stainless Steel Version Models /160, Stainless Steel Safety Version

Differential pressure gauge with micro switches With integrated working pressure indication (DELTA-comb) Model DPGS40TA, with component testing

Differential pressure gauge with micro switches With integrated working pressure indication (DELTA-comb) Model DPGS40

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Measuring insert For thermocouple with flameproof enclosure (TC10-L) Model TC10-K

Cable resistance thermometer Model TR40

Gas-actuated temperature switch Stainless steel switch enclosure Model TWG

Resistance thermometer with digital indicator Model TR75, battery operation

Machine glass thermometers Model 32, V-Form

Diaphragm seal with threaded connection Plastic version Model

Bourdon tube pressure gauge per DIN Panel mounting series for rail-vehicle braking systems Model PG21PB, NS 60, 80 and 100

Resistance thermometer Without thermowell Model TR10-H

Diaphragm pressure gauge, flush For sanitary applications Model PG43SA-S, NS 100

Duplex pressure gauge per DIN Panel mounting series for rail-vehicle braking systems Model PG21DPB, NS 60, 80, 100 and 130

Differential pressure gauge Model , copper alloy Model , stainless steel version

Temperature multi-function calibrator Model CTM

Thermocouple For additional thermowell Model TC10-B

Diaphragm seal with flange connection For the pulp and paper industry Model

Thermocouple Without thermowell Model TC10-H

Cable thermocouple Model TC40

Diaphragm seal with sterile connection With clamp connection (Tri-clamp) Models , and

Duct thermometer Model TF40

Insertion thermometer With connection lead Model TF45

Diaphragm seal with sterile connection With union nut (milk thread fitting) Models , , and

Measuring insert for resistance thermometer Model TR10-A

Diaphragm seal with sterile connection For homogeniser machines Model

Differential pressure gauge with electrical output signal Model A2G-15

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

Differential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA

Resistance thermometer For sanitary applications Model TR22-B, for orbital welding

Reed sensor For bypass level indicators Model BLR

Differential pressure switch Model DPS40

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35

Pressure Gauge. Bourdon Tube Pressure Gauges with Switch Contacts Models MBSA, Stainless Steel Version. Applications. Special Features.

Accessories for diaphragm seals Block flange and saddle flange Models , ,

Compact differential pressure switch Models DC, DCC

Hot runner thermocouple Model TC46

Float switch For horizontal installation, miniature design Model HLS-M

Compact pressure switch Model PCS

Diaphragm pressure gauge, flush For sanitary applications, NS 100 Model PG43SA-D, with integrated diaphragm element monitoring

Thermowell For sanitary applications Model TW61, for orbital welding

Thermowell For sanitary applications Model TW61, for orbital welding

Cable resistance thermometer Model TR40

Resistance Thermometers Model TR602, for Flat Surfaces Model TR603, for Pipe Surfaces

Threaded resistance thermometer With perforated thermowell model TW35 Model TR10-J

Mini pressure switch Stainless steel switch enclosure Model PXS

Resistance thermometer For sanitary applications, exchangeable sensor Model TR22-A

Cable resistance thermometer Model TR40

Thermocouple with spring-loaded tip Model TC55

Resistance thermometer Model TR10-B, for additional thermowell

Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40

Resistance thermometer For sanitary applications Model TR22-A, exchangeable sensor

Cable thermocouple Model TC40

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

Resistance thermometer Model TR10-E, for additional thermowell

Tubeskin thermocouple assembly Model TC59-W

Thermocouple Model TC10-H without thermowell

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module

Diaphragm seal with sterile connection For sanitary applications Models , , and , threaded connection

Tubeskin thermocouple assembly Model TC59-V

Pressure gauge per EN with mounted diaphragm seal With threaded connection, threaded design Model DSS10M

In-line diaphragm seal with sterile connection For sanitary applications Model , aseptic connection per DIN 11864

Pressure switch, high adjustability of switch differential

High-pressure thermocouple Model TC90

Level sensor Magnetostrictive, high-resolution measurement principle Model FLM-H, for sanitary applications

Float switch For industrial applications, with temperature output Model RLS-3000

Pressure gauge per EN with mounted diaphragm seal With SMS threaded connection Model DSS19F

Tubeskin thermocouple assembly Model TC59-V

Thread Mounted Resistance Thermometers Model TR201, with Fabricated Thermowell

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Transcription:

Temperature Gas-actuated thermometer with switch contacts Stainless steel version Model 73 WIKA data sheet TV 27.01 for further approvals see page 12 Applications Control and regulation of industrial processes Monitoring of plants and switching of electric circuits Universally suitable for machine building, plant, vessel, apparatus construction and food industry Temperature measurement without any contact to the medium Mounting in instrument boards, control cabinets, control panels Special features Instruments meet the highest standards of measurement technology Case and stem from stainless steel For external mounting on pipes and tanks Gauges with inductive contact for use in hazardous areas with ATEX approval Gauges with electronic contact for PLC applications Description Wherever the process temperature must be shown in situ or in hard-to-reach locations, and where, at the same time, an electrical circuit also needs to be switched, the gas-actuated thermometers with switch contacts are ideally suited. Due to the wide variety of possible designs, the model 73 gas-actuated thermometers can be perfectly adapted to any process connection or location. The adjustable stem and dial version can be adjusted to any angle to allow easy reading. With the contact bulb version (without any contact with the medium), temperature measurements are possible even when the pipe diameter is extremely small. When mounting this thermometer version, it must be ensured that the contact bulb is in contact with the measuring point over its complete length. Fig. top: with capillary Fig. bottom: back mount (BM) Switch contacts (electrical alarm contacts) make or break an electric control circuit dependent upon the position of the instrument pointer. The switch contacts are adjustable over the full measuring range. The instrument pointer actual value pointer) moves freely across the entire scale range, independent of the setting. The set pointer can be adjusted via the window using a removable adjustment key (mounted on the terminal box). Switch contacts consisting of several contacts can also be set to a single set point. Contact actuation is made when the actual value pointer travels beyond or below the desired set point. For switch contacts, magnetic snap-action contacts, inductive contacts - for requirements to ATEX - or electronic contacts for PLC switching are available. Page 1 of 13 Data sheets showing similar products and accessories: Electrical switch contacts; model 8xx; see data sheet AC 08.01

Standard version Measuring principle Gas-pressure inert gas filling, physiologically safe Nominal size in mm 100, 160 Connection design S Standard (male thread connection) 1) 1 Plain stem (without thread) 2 Male nut 3 Union nut 4 Compression fitting (sliding on stem) 5 Union nut with fitting 6 Compression fitting (can be adjusted on either capillary or spiral protection hose) 7 Compression fitting at the case 1) Not for gauges with capillary Models Back mount (axial) Lower mount (radial) Back mount, adjustable stem and dial Instruments with capillaries Accuracy class Class 1 per DIN 16196 at 23 C ±10 C ambient temperature Working range Normal (1 year): Measuring range (DIN 16196) Short time (24 h max.): Scale range (DIN 16196) Rated operating ranges and conditions DIN 16196 (EN 13190) Capillary Ø 2 mm, stainless steel 1.4571, bending radius no less than 6 mm Length to user specifications Dial Aluminium white, black lettering Window Laminated safety glass Pointer Aluminium, black, adjustable pointer Electrical connection Terminal box Temperature limits for storage and transport -50 +70 C without liquid damping -40 +70 C with liquid damping Permissible ambient temperature -20 +60 C without/with liquid damping Permissible pressure rating at the stem max. 25 bar, static Ingress protection IP65 per EN/IEC 60529 Mounting types for instruments with capillary Surface mounting flange, stainless steel Surface mounting bracket, aluminium die cast Panel mounting flange, stainless steel Case, bezel ring Stainless steel 1.4301 Process connection, stem Stainless steel 316SS Adjustable stem and dial Stainless steel swivelling 90 rotatable 360 Panel frame Steel, galvanised Contact bulb 120 x 22 x 12 mm, stainless steel 1.4571 Page 2 of 13

Switch contacts Magnetic snap-action contact model 821 Simple construction No control unit and no extra power supply required Direct switching up to max. 230 V, 50 VA / 30 W Up to 4 switch contacts per measuring instrument Inductive contact model 831 Long service life due to non-contact sensor Additional control unit required With corresponding control unit suitable for use in zone 1 / zone 21 (2 GD) hazardous areas Low effect on the indication accuracy Fail-safe switching at high switching rates Insensitive to corrosion Also in safety version (SN, S1N contact) Up to 3 switch contacts per measuring instrument Electronic contact model 830 E For direct triggering of a programmable logic controller (PLC) No additional control unit required Long service life due to non-contact sensor Low effect on the indication accuracy Fail-safe switching at high switching rates Insensitive to corrosion Up to 3 switch contacts per measuring instrument Switching function The switching function of the switch is indicated by function index 1, 2 or 3. Model 8xx.1: Contact makes (clockwise pointer motion) Model 8xx.2: Contact breaks (clockwise pointer motion) Model 8xx.3: Change over; one contact breaks and one contact makes simultaneously when pointer reaches set point Please indicate switch points! Unless otherwise specified, the instrument will be delivered with the adjustable switching points factory-set as follows: Single contact Start of measuring range Double contact Start and end of the measuring range Triple contact Start, middle and end of the measuring range Note For magnetic snap-action contacts, it does not make sense to test the display, around the set limit values, in the range ±5 % of the measuring span, because the magnet has an influence on the indication accuracy. For further information see data sheet AC 08.01, Electrical switch contacts Options Scale range F, C/ F (dual scale) Case with liquid damping Case with food-compatible liquid damping Case from stainless steel 1.4571 Armoured coating for capillary: Ø 7 mm spiral protective sleeve, flexible or PVC coated 6, 10, 12 mm (others on request) Special measuring ranges or dial printing to customer specifications (on request) Version per ATEX Ex II 2 GD c TX Ambient temperature: -40... +60 C (for SN contact) Scale ranges, measuring ranges 1), error limits (DIN 16196) Scale graduation per WIKA standard Scale range in C Measuring range in C Scale spacing in C -80... +60-60... +40 2 3.0-60... +40-50... +30 1 1.5-40... +60-30... +50 1 1.5-30... +50-20... +40 1 1.5-20... +60-10... +50 1 1.5-20... +80-10... +70 1 1.5 0... 60 10... 50 1 1.5 0... 80 10... 70 1 1.5 0... 100 10... 90 1 1.5 0... 120 10... 110 2 3.0 0... 160 20... 140 2 3.0 0... 200 20... 180 2 3.0 0... 250 30... 220 5 3.75 0... 300 30... 270 5 7.5 0... 400 50... 350 5 7.5 0... 500 50... 450 5 7.5 0... 600 100... 500 10 15.0 0... 700 100... 600 10 15.0 1) The measuring range is indicated on the dial by two triangular marks. Only within this range is the stated error limit valid per DIN 16196. Error limit ± C Page 3 of 13

Connection design Design standard (male thread connection) 1) Standard insertion length l1 = 63, 100, 160, 200, 250 mm 3073050.05 NS G i SW 4 1) Not for gauges with capillary 4 Diameter of the sealing collar SW Flats Design 1, plain stem (without thread) Standard insertion length l1 = 100, 140, 200, 240, 290 mm Nominal size Dimensions in mm NS d 2) 1 a for a for axial adjustable stem and dial 3073050.05 100, 160 18 8 15 25 2) Not applicable to version with capillary a Distance to case/ articulated joint 1 Plain diameter Design 2, male nut Standard insertion length l 1 = 80, 140, 180, 230 mm NS G i SW 100, 160 G ½ B 20 27 8 M20 x 1.5 15 22 8 3073050.05 incl. collar SW Flats Design 3, union nut Standard insertion length l1 = 89, 126, 186, 226, 276 mm NS G i SW 100, 160 G ½ B 8.5 27 8 G ¾ B 10.5 32 8 M24 x 1.5 13.5 32 8 G 1 Female thread SW Flats 3073050.05 Page 4 of 13

Design 4, compression fitting (sliding on stem) Insertion length l 1 = variable Length L = l 1 + 40 mm 3073050.05 NS G i SW 4 M18 x 1.5 12 24 23 8 Sealing ring 4 Diameter of the sealing collar SW Flats Design 5, union nut with fitting Standard insertion length l1 = 63, 100, 160, 200, 250 mm NS G i SW 4 M18 x 1.5 12 24 23 8 4 Diameter of the sealing collar SW Flats 3073050.05 Option: Connection with union nut M24 x 1.5 with fitting M18 x 1.5 NS G i SW 4 100, 160 M18 x 1.5 12 32 23 8 Design 6.1, compression fitting sliding on capillary (compression fitting is leak-proof) Insertion length l 1 = variable L: standard 200 mm at = 6 mm standard 170 mm at = 8 mm standard 100 mm at = 10 mm NS G i SW 4 Sealing ring I F Capillary length 4 Diameter of the sealing collar SW Flats 3073300.12 Page 5 of 13

Design 6.2, compression fitting sliding on capillary with spiral protection hose (compression fitting is leak-proof) Insertion length l1: 300 mm at = 6 or 8 mm 200 mm at = 10 mm L: standard 200 mm at = 6 mm standard 170 mm at = 8 mm standard 100 mm at = 10 mm NS G i SW 4 Sealing ring I F Capillary length 4 Diameter of the sealing collar SW Flats 3073300.12 Design 6.3, compression fitting sliding on spiral protection hose (compression fitting is not leak-proof) Insertion length l 1 = variable L: standard 200 mm at = 6 mm standard 170 mm at = 8 mm standard 100 mm at = 10 mm NS G i SW 4 Ferrule I F Capillary length 4 Diameter of the sealing collar SW Flats 3073300.12 Design 7, compression fitting at the case Insertion length l 1 : 400 mm L: standard 200 mm at = 6 mm standard 170 mm at = 8 mm standard 100 mm at = 10 mm l B = standard 100 mm (others on request) NS G i SW 4 Sealing ring I F Capillary length I B Mounting shaft 4 Diameter of the sealing collar SW Flats 14042662.02 Note for designs 6.1, 6.2, 6.3 and 7: With some combinations, the active length can correspond to the sensor length L. If an additional compression fitting is desired on the stem, the sensor length L increases by at least 60 mm. Page 6 of 13

Dimensions in mm Back mount (BM) 11442522.02 Lower mount (LM) 11442850.01 Back mount (BM) Adjustable stem and dial 11443171.01 Back mount (BM), lower mount (LM) Nominal size Dimensions in mm Switch contact models 821 or 831 1- or 2-way 3-way NS b b 1 1) b b 1 1) d d 4 D 1 D 2 F 1) G SW 100 88 121 - - 8 2) 26 101 99 83 G ½ B 27 1.3 160 88 121 96 129 8 2) 26 161 159 113 G ½ B 27 1.5 Weight in kg Back mount (BM), adjustable stem and dial Nominal size Dimensions in mm Switch contact models 821 or 831 1- or 2-way 3-way NS b b 1 b b 1 d D 1 D 2 F 100 88 131 - - 8 2) 101 99 68 1.5 160 88 131 97 140 8 2) 161 159 68 1.7 1) With scale ranges 0... 300 C the dimensions increase by 40 mm 2) Option: 6, 10, 12 mm Weight in kg Page 7 of 13

Dimensions in mm for instruments with capillary Surface mounting flange Instrument mounting bracket 11443872.01 1144674.01 Instruments NS 100 with panel mounting flange 11444274.01 Instruments NS 160 with panel mounting flange 11444509.02 Nominal size Dimensions in mm Switch contact models 821 or 831 1- or 2-way 3-way NS b b 1 b b 1 d d 1 d 2 d 3 D 1 D 2 D 3 h 100 88 91 - - 8 2) 116 132 4.8 101 99 107 107 1.6 160 88 91 97 100 8 2) 178 196 5.8 161 159 166 172 2.0 Weight in kg 2) Option: 6, 10, 12 mm Page 8 of 13

Dimensions in mm for instruments with contact bulb Back mount (BM) 11443413.01 Lower mount (LM) Back mount, adjustable stem and dial 11443723.01 11443812.01 Connection location Nominal size Dimensions in mm Switch contact models 821 or 831 Weight in kg 1- or 2-way 3-way Back mount (BM) NS b b 1 b b 1 D 1 D 2 100 88 - - - 101 99 1.0 160 88-97 - 161 159 1.1 Lower mount 100 88 - - - 101 99 1.0 Adjustable stem and dial 160 88-97 - 161 159 1.1 100 88 131 - - 101 99 1.1 160 88 131 97 140 161 159 1.2 Page 9 of 13

Dimensions in mm for instruments with contact bulb and capillary Surface mounting flange Instrument mounting bracket 11445092.01 11445165.01 Instruments NS 100 with panel mounting flange Instruments NS 160 with panel mounting flange 11445114.01 11445149.02 Nominal size Dimensions in mm Switch contact models 821 or 831 1- or 2-way 3-way NS b b 1 b b 1 d 1 d 2 d 3 D 1 D 2 D 3 h 100 88 91 - - 116 132 4.8 101 99 107 107 1.6 160 88 91 97 100 178 196 5.8 161 159 166 172 2.0 Weight in kg Page 10 of 13

Mounting instructions for contact bulb General The contact bulb has been designed for mounting on pipes or tanks. When mounting this thermometer version, it must be ensured that the contact bulb is in contact with the measuring point over its complete length. The basic requirements to ensure a perfect measurement result is to retain good thermal contact between the skin mounted contact bulb and the outside wall of the pipe or tank with minimal heat loss to ambient from the skin mounted contact bulb and measuring point. Bend protector Capillary 3107876.01 Mounting on pipes The geometry of the contact bulb has been designed for pipes with external diameters between 20 and 160 mm. The skin mounted contact bulb should have direct metallic contact with the measuring point and have firm contact with the surface of the pipe. Where temperatures under 200 C are to be expected, a heat conducting paste can be used to optimise the heat transmission between skin mounted contact bulb and pipe. Lagging must be applied where the skin mounted contact bulb has been mounted, in order to avoid error due to heat loss. This lagging must have sufficient temperature resistance and is not provided with the instrument. Tube clip mounting Lagging 3107922.01 Mounting on tanks The geometry of the contact bulb has been designed for tanks with an external radius up to 80 mm. If the mounting point of the skin mounting contact bulb on the tank has an external radius greater than 80 mm, we recommend the use of an intermediate piece designed for the respective tank diameter, made of a material with good thermal conductivity. The contact bulb should be fastened to the tank by means of an angle bracket with clamping screws, or any similar method. The skin mounted contact bulb should have direct metallic contact with the measuring point and have firm contact with the surface of the tank. A heat conductive paste can be used to optimise the heat transmission between skin mounted contact bulb and tank if temperatures under 200 C are to be expected. Lagging must be applied where the skin mounted contact bulb has been mounted, in order to avoid error due to heat loss. This lagging must have sufficient temperature resistance and is not provided with the instrument. Angle bracket mounting Lagging 3107930.01 Page 11 of 13

Thermowell In principle, the operation of a mechanical thermometer without a thermowell with low process-side loading (low pressure, low viscosity and low flow velocities) is possible. However, in order to enable exchanging the thermometer during operation (e.g. instrument replacement or calibration) and to ensure a better protection of the instrument and also the plant and the environment, it is advisable to use a thermowell from the extensive WIKA thermowell portfolio. For further information on the calculation of the thermowell, see Technical information IN 00.15. Approvals Logo Description Country EU declaration of conformity ATEX directive (option) Hazardous areas Zone 1 gas II 2G Ex h IIC T6... T1 Gb X Zone 21 dust II 2D Ex h IIIC T85... T450 C Db X EAC (option) Import certificate EMC directive Hazardous areas Zone 1 gas [II Gb c T* X] Zone 21 dust [III Db c T* X IP66] GOST (option) Metrology, measurement technology KazInMetr (option) Metrology, measurement technology - MTSCHS (option) Permission for commissioning BelGIM (option) Metrology, measurement technology Uzstandard (option) Metrology, measurement technology - CRN (option) Safety (e.g. electr. safety, overpressure,...) European Union Eurasian Economic Community Russia Kazakhstan Kazakhstan Belarus Uzbekistan Canada Certificates (option) 2.2 test report 3.1 inspection certificate DKD/DAkkS calibration certificate Approvals and certificates, see website Page 12 of 13

Ordering information Model / Nominal size / Type of contact and switching function / Scale range / Design of connection / Process connection / Length I 1 / Capillary length IF / Options 2009 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. 08/2018 EN Page 13 of 13 WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. +49 9372 132-0 Fax +49 9372 132-406 info@wika.de www.wika.de