Installation Guidelines

Similar documents
Installation Guidelines

Installation Guidelines

Degas. Installation and Service Instructions. Tub-Shower Systems S-5400, S-5401, S-5402 Series

Dia. S Shower Valve System. S-3500TS-X... Valve includes stops. Arm and flange 300S. Screwless escutcheon kit RTS-011, brass RTS-012, plastic

Degas Shower Valve System 5400-X... Valve includes stops 5400-TRM... Trim only

Dia. Installation and Service Instructions. Tub-Shower Systems 3520-B, 3521-B, 3522-B Series

Lucetta. Shower-Hand Shower System, 4605 / 4600 Installation and Service Instructions. Visual Guide Lucetta Shower-Hand Shower System, 4605 (4600)

INSTALLATION, OPERATION & SERVICE INSTRUCTIONS

Installation Guidelines

INSTALLATION MANUAL IMPORTANT CONSIDERATIONS TECHNICAL INFORMATION. Tools you may need

Installation Instructions

INSTALLATION, OPERATION & SERVICE INSTRUCTIONS

INSTALLATION GUIDELINES

PILLOWS DECK-MOUNT BATH FAUCET WITH FLUME SPOUT

INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL IMPORTANT CONSIDERATIONS TECHNICAL INFORMATION. Tools you may need

INSTALLATION, OPERATION & SERVICE INSTRUCTIONS

Installation Guide. Single-Control Bath and Shower Trim A K K K 12021

Installation and Maintenance Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

Installation Guide. Single-Control Bath and Shower Trim A K T948, K T949, K T950 K 951, K 952

Maintenance Information

Installation Instructions for Pressure Balancing Valve Set with Volume Control. Limited Lifetime Faucet Warranty

FOR TECHNICAL ASSISTANCE

1 - S-2251 Showerhead 6 - S-2288 Showerhead AP - Anchor Plate (S-2280 Showerhead Only)

Installation Instruction for Valve: DFPHY.ID Trim Application: Pressure Balance Tub & Shower

Thermostatic Floor-Mounted Bathtub Mixer

INSTALLATION INSTRUCTIONS

Installation Instructions 1662SG SG.222

Installation Instructions 1662SG SG.224

Installation Guide. Single-Control Bath and Shower Trim A K-T14420, K-14421, K-14422, K-T14423, K-14424, K-14426, K-14427

4 - Way Control 4 - Way Control 4 - Way Control with lock

Installation Instructions

Deck-Mounted Bath Set with Diverter

Installation Instructions

INSTALLATION INSTRUCTIONS

DP5 Pump. 5:1, Air-operated, Heavy Duty, Oil. General. Operation. Technical Data. Installation R1 09/10

Maintenance Information

INSTALLATION INSTRUCTIONS

Installation Instructions

Series 2200/2220 Control Valve. Operation and Maintenance SCOPE OF MANUAL MAINTENANCE DESCRIPTION VALVE INSTALLATION

Installation Instructions 1662SG SG.223

Backpack Sprayer. CAUTION: Read and follow all instructions. Use and Care Manual NO LEAK BACKPACK SPRAYER

WARNING Carefully Read These Instructions Before Use

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

SS-PAM PRESSURE ACTUATED MIXER Serial No. PGS0001 and higher ½ top inlets INSTALLATION INSTRUCTIONS 7 6

SS-LVC THERMOSTATIC MODEL Serial No. LV and higher ½ top inlets INSTALLATION INSTRUCTIONS

Allura. Widespread Lavatory Faucet SLW-4712 Installation and Service Instructions. Quick Install Guide Allura Widespread Lavatory Faucet, SLW-4712

INSTALLATION, OPERATING AND SERVICE MANUAL

M-5000/5700 Instant Hot Water Maker

INSTALLATION GUIDE KPF Single Lever Kitchen Faucet With Pull-Out Sprayer

THREE-VALVE BATH & SHOWER Cast Brass Body

Sachs 48mm Closed Cartridge fork Service Manual

Sachs shock manual. ( ) 2 & 4 Stroke RR Enduro. ( ) RS Dual Sport

Supplies Required. Teflon Tape Allen Key Wrenches Screwdriver 1/2" NPT Brass Pipe Plug Adjustable Wrench IMPORTANT!

INSTALLATION/OPERATION/MAINTENANCE INSTRUCTIONS FOR ARCHON MODELS WD2010L, WD2010, WD2010H WASHDOWN STATIONS. ARCHON Industries, Inc.

Installation Instructions

Instructions. Certifications Chrome less spray Chrome with spray 10-K82-WNCH-AD-Z Chrome less spray 10-K82-WYCH-AD-Z Chrome with spray

INSTALLATION INSTRUCTIONS

RSV16 Retro-Fit Cartridge Acorn Controls SV16 Valve Cartridge

Tri-Clover Manual and Air Actuated Fractional Valves

Maintenance Information

Installation Instructions

SERIN MONOBLOCK LAVATORY FAUCET with

Backpack Sprayer. Use and Care Manual

I & M 8000 Series. Ideal Installation Schematic. Preferred Installation. Trouble Shooting

M-5000TG/5700TG Steam and Cold Water Mixing Unit

Installation Instructions

Instructions. Certifications. Two Handle Kitchen Faucet. Tools Required. Maintenance. Safety Tips. Important Points. Things You May Need.

M-5000TG/5700TG Steam and Cold Water Mixing Unit

CALIFORNIA TRIMMER MOWER MAINTENANCE MANUAL

Crispin Valves Operating Guide. Crispin

Operation and Maintenance Manual

X-Trainer 43mm fork service manual. Beta USA, Inc This work should be performed by a trained motorcycle technician.

Service Guide. High-Pressure Grease Pump. 100 psi (6.8 bar) High-Pressure Pump Model 7785 Series Specifications

PNEUMATIC SLIDING VALVE

KEEP THIS INSTRUCTION BOOKLET FOR FUTURE REFERENCE

CW-2651 (WL1100) CB-2651 (BL1100)

GH-BETTIS OPERATING & MAINTENANCE INSTRUCTIONS DISASSEMBLY & ASSEMBLY FOR THE T80X-M4-S DOUBLE ACTING SERIES HYDRAULIC ACTUATORS

Installation Guide. 3-Way/2-Way Transfer Valve E

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

SB-1821-E. Instructions for Models: What You Need To Know: Tools: Required: Need Help? For additional assistance or service call: Helpful:

INSTALLATION INSTRUCTIONS FOR DECK TUB SETS with HAND SHOWER Valves Numbered: &

Installation Instructions / Warranty. Starck 10456XX1

SM Valve Installation

Operating & Maintenance Manual For Steam Conditioning Valve

Maintenance Information

Insta-Valve 250 Patriot TM

DYNAFLUID 2000 STEAM & WATER MIXING VALVE INSTALLATION & OPERATING MANUAL

Installation Instructions

BETTIS SERVICE INSTRUCTIONS DISASSEMBLY AND REASSEMBLY FOR CB-SR-S SEISMIC SPRING RETURN SERIES PNEUMATIC ACTUATORS

I & M Mark 708ME. Ideal Installation. Start-Up Procedure. Installation & Maintenance Instructions for Mark 708 & Motor Actuator

DA Series Diaphragm Valve

Transcription:

JUSV4-K (metal lever handle) & GUSVR (rough) JUSV4-K (white porcelain lever handle) & GUSVR (rough) JUSV43-K (black porcelain lever handle-mto) & GUSVR (rough) 5 " Shower Outlet Tub Outlet 3 "± " IMPORTANT To ensure this product is installed properly, you must read and follow these guidelines. The owner/user of the valve must keep this information for future reference. The risk of scalding exists until the installer has properly set the temperature high limit stop. This product must be installed by a professional contractor and conform to all applicable codes Refer to the specification and assembly drawings attached. Valves are sold partially assembled but shown fully disassembled for illustrative and service purposes only. If soldering any connections, remove diverter assembly and cartridge to prevent damage to seals. This valve should be on-site prior to rough in and allows the installer to visualize the installation. Inspect this product to assure you have all parts required for proper installation. Surface of finished wall Check incoming water pressure; ideal operating pressure is 40-50 psi. The minimum is 5 psi. and the maximum is 0 psi. Use only a strap wrench or protected/smooth-jaw wrench on any finished surface. 3 5 " ROUGH IN: (GUSVR ROUGH SOLD SEPARATELY): IMPORTANT - remove cartridge (-4) and diverter assembly (-30) when soldering any connections. Failure to remove the cartridge and diverter will damage both assemblies.. Install rough piping and valve body as shown. -Refer to marking on valve body when installing. When facing valve, HOT 'H" is on the left and COLD 'C' is on the right. -Valve should be installed with the plastic tile guard lettering face flush with the finished wall.. Tile finished surface of wall, be careful to keep all ports free of obstructions. 3. Turn on the hot and cold supplies and flush out the valve. -Valve will not operate unless both hot and cold water are turned on. -Allow valve to run in warm position for a few minutes to totally flush the system. IF SYSTEM IS EXCESSIVELY DIRTY, REMOVE THE CARTRIDGE (-4) ASSEMBLY TO ENSURE PROPER FLUSHING. 4. Tighten packing nut (0) for desired rotational resistance in handle. VALVE OPERATION: 5. When the finished wall is complete, open the hot and cold supplies. The supplies are opened by removing the service stop cap () and stop retainer (5) then turning the 3 " hex screw () counter clockwise. Both supplies must be on or the valve will not operate.. Pull off the tile shield and discard.. The larger of the two handles is for controlling temperature only, not volume. The smaller handle is used to divert the water in a tub and shower combination and cannot be used to supply water to a handshower. Install the large handle (-f) so it rests at o-clock in the OFF position then turn the handle counter clockwise through the cold position then warm and stopping at the hot position. If additional rotational friction is required to maintain the handle position, tighten the packing nut (0). JULIA PRESSURE BALANCE VALVE TRIM WITH DIVERTER (JUSV4-K, 4-K, 43-K & 0.0.0

. Allow the valve to run in warm position for a few minutes to completely flush the system. If system is quite dirty, remove the cartridge to ensure proper flushing. 9. IMPORTANT: This valve is equipped with a limit stop screw (, 9) to be used to limit the valve handle from being turned to excessively hot water discharge temperatures. 0. Setting the limit stop screw: Open the valve to the maximum desired temperature then turn the limit stop screw () in until it seats.. WARNING: FAILURE TO ADJUST THE LIMIT STOP SCREW PROPERLY MAY RESULT IN SERIOUS SCALDING. INSTALL THE TRIM: Note: Part numbers refer to trim and/or rough exploded view drawings.. Hand tighten the dome cover (5) completely onto the packing nut (0). The dome cover MUST be tightened to prevent damage to the handle. 3. Moisten the o-ring (a) then slide the diverter assembly and plate (-b, -b) trim over the dome cover while making sure the diverter shaft/handle () is aligned with the diverter spindle (-30). IMPORTANT: The diverter must be properly aligned and the handle must rest at o-clock position. If the handle and diverter spindle are not properly aligned, the valve will not function. See Figure. 4. Secure the plate to the wall using the two screws (). 5. Pull off the indice assembly (-c) from the handle, position then hold handle spacer (4) onto the spindle. Secure the handle by tightening the screw (3) then reinstall the indice assembly.. Open the valve and confirm the temperature setting, adjust as required. Verify that the diverter is functioning properly. NOTE: a small amount of water may trickle from the tub spout when the diverter is set in the shower position and is not considered a defect. SERVICE NOTE: REFER TO EXPLODED VIEW DRAWING FOR SERVICE PART CALL OUTS. A TROUBLE SHOOTING GUIDE IS ALSO INCLUDED.). Remove valve trim..shut-off water to the valve. Remove the service stop cap (), stop retainer (5) and tighten valve stop () with a 3 " hex wrench. 9.CAUTION: Before removing main cap/bonnet nut (3) use the following sequence to avoid damage to the stem: -Unthread the adjustment screw (9) until the o-ring is fully exposed. -Open valve to full hot and unscrew cap/bonnet nut (3). Loosen but leave packing nut (0) in place when removing cap/bonnet nut to avoid damage to packing assembly. -Control stem/spindle (-4) will be removed with the cap/bonnet nut. 0.Replace appropriate parts as needed and inspect seats and o-rings for any visible wear..extended Service: -Control Stem/Cartridge: the end of the control stem that is the furthest point into the valve is the most important part. This houses the stainless steel control piston (). -Shake the stem and listen for the piston to be moving back and forth. A freely moving piston makes a knocking noise similar to an empty spray paint can. -If a noise is not detected, check for obstructions such as flux, solder, saw dust etc. Soak in mineral deposit de-scaler if necessary. -Replace the cartridge if the piston does not move freely. -Seat replacement: requires seat replacement tool and appropriate parts..reinstall the valve in reverse sequence. If further assistance is required, please contact Product Support at -00-9-0 (am-pm EST). JULIA PRESSURE BALANCE VALVE TRIM WITH DIVERTER (JUSV4-K, 4-K, 43-K & 0.0.0

MAINTENANCE INSTRUCTIONS PROBLEM CAUSE SOLUTION Valve will not flow water Hot and cold water not turned on. service stops not opened. Be sure both supplies are turned on and service stops are opened. Valve will not operate unless both HOT and COLD water inlets have pressure. Valve leaks when shut-off. Hot and cold water washers are worn, or foreign matter (solder, chips, etc.) are between washers and seat surfaces. Replace Hot and Cold washers and inspect top surface on hot and cold seats for damage. Water volume from valve is inconsistent during operation. Valve delivers an insufficient quantity of Hot and Cold water. Temperatures fluctuates without moving temperatures handle. Temperatures out of valve reduces gradually during use. While using a tub & shower valve with integral diverter set for shower, a trickle of water runs from tub spout. Pressure balancing piston housed in control spindle assembly is blocked from free movement by foreign matter. Supply system is running out of hot water. This is a design function of the valve. Water is allowed to trickle from the tub spout when diverter is set in shower position; in accordance to national standards. With valve open half way, remove temperature handle and tap spindle with plastic hammer. If problem is not solved, remove spindle assembly completely and tap handle end against a solid object to free piston. Rinse out control sample assembly. Soaking in household vinegar will help free foreign matter build-up. Reduce maximum flow rate out of valve or shower head. This will allow longer period of use before reduction of hot water supply. This is a design function in accordance to national standards. JULIA PRESSURE BALANCE VALVE TRIM WITH DIVERTER (JUSV4-K, 4-K, 43-K & 0.0.0

3 5 4 0 9 3 5 9 30 4 3 4 0 9 REPLACEMENT PART KITS CONTROL STEM REPLACEMENT KIT CAP GASKET CONTROL STEM CONTROL PISTON 3 COLD WASHER RETAINER 4 COLD WASHER HOT WASHER WASHER RETAINING SCREW SEAT REPLACEMENT KIT COLD SEAT O-RING 9 INT. COLD SEAT O-RING 0 HOT WATER SEAT COLD WATER SEAT REPLACEMENT PART KITS ADJUSTMENT SCREW REPLACEMENT KIT 9 ADJUSTMENT SCREW O-RING CAP REPLACEMENT KIT CAP GASKET 3 BONNET 4 O-RING WASHER 5 O-RING PACKING WASHER RUBBER PACKING ADJUSTMENT SCREW 9 ADJUSTMENT SCREW O-RING 0 PACKING NUT SEAT REPACEMENT KIT COLD SEAT TOOL HOT SEAT TOOL CONTROL STEM WASHER REPLACEMENT KIT CAP GASKET 3 COLD WASHER RETAINER 4 COLD WASHER HOT WASHER WASHER RETAINING SCREW SERVICE STOP REPLACEMENT KIT VALVE STOP 3 STOP O-RING 4 STOP GASKET PACKING REPLACEMENT KIT CAP GASKET 4 O-RING WASHER 5 O-RING PACKING WASHER RUBBER PACKING ADDITIONAL ITEM LIST VALVE BODY 5 STOP RETAINER SERVICE STOP CAP DIVERTER SPINDLE DIVERTER SPINDLE O-RING 9 DIVERTER KEY 30 DIVERTER RETAINER JULIA PRESSURE BALANCE VALVE TRIM WITH DIVERTER (JUSV4-K, 4-K, 43-K & 0.0.0

JUSV4-K, 43-K a b a b f e 3 c b a d 5 4 c b PARTS TABLE HANDLE CAP, OUTER a HANDLE b HANDLE SHAFT c O-RING d HANDLE CAP, INNER e HANDLE BASE f HANDLE POINTER INDICE TRIM RING a INDICE, BLANK b INDICE CAP c O-RING 3 SCREW, HANDLE 4 HANDLE SPACER 5 DOME COVER, THREADED a DIVERTERR HANDLE BUSHING b a b C-CLIP FACE PLATE SCREW FACE PLATE O- RING, FACE PLATE GASKET, FACE PLATE FIGURE a JULIA PRESSURE BALANCE VALVE TRIM WITH DIVERTER (JUSV4-K, 4-K, 43-K & 0.0.0