Installation and Operation Manual Back-UPS BR1000-CH

Similar documents
Installation and Operation Manual Back-UPS BR800/1100CI-IN

Installation and Operation Manual Back-UPS BX1100CI-CN

Installation and Operation Back-UPS BX550CI-CN

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

User Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

Installation and Operation Smart-UPS SUA500PDR

Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software

3000VA 120/208/230VAC

User Manual Back-UPS BE425M/425M-LM, BN450M/450M-CA

Back-UPS CS Back-UPS CS 350

User Manual. English. APC Smart-UPS. 750/1000/1500 VA 100/120/230 Vac 2U Rack-Mount Uninterruptible Power Supply

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

Installation and Operation

User Manual. Smart-UPS. Uninterruptible Power Supply. 1000/1500 VA 100/120/230 Vac. 750XL/1000XL VA 120/230 Vac. Tower

User Manual. Smart-UPS. Uninterruptible Power Supply 750/1000 VA. 100/120/230 Vac. Rack Mount 1U

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

Operation Manual. Smart-UPS C. Uninterruptible Power Supply 1000/1500/2000/3000 VA. 120/230 Vac. Tower. su0813a

Operation Manual. English. APC Smart-UPS VA 3U Rack and Stack Uninterruptible Power Supply 230 Vac , Revision 1 12/00

Installation Guide. Marine Filter SURT023M SURT024M

Broadband PowerShield. CP27U Models. User Manual

Installation and Operation

SUA1000I-IN / SUA1500I-IN 230 VAC

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

APC Smart-UPS RT UX. User s Manual. Models SURT1000UXI and SURT2000UXI 220/230/240 Tower/Rack Mount Uninterruptible Power Supply.

Installation Guide Smart-UPS X 2000/2200/3000 XL Tower/Rack-Mount 4U

Operation Manual. Smart-UPS. Uninterruptible Power Supply. Rack-Mount 1U. 1200/1500 VA 100/120/230 Vac

User s Manual. English. APC Smart-UPS RT. 3000/5000 VA VAC 3U Tower/Rack Mount Uninterruptible Power Supply

User Manual Easy UPS On-Line SRV Series 1000VA, 2000VA, 3000VA

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

Operation Manual. Smart-UPS. Uninterruptible Power Supply. 750/1000/1500/2200/3000 VA Tower 100/120/230 Vac. 500 VA Tower 100 Vac

APC Smart-UPS 2200/3000 VA 230 VAC. Uninterruptible Power Supply

APC Smart-UPS RT UXI/UXICH

Installation and Operation

Smart-UPS RC External Battery Pack Tower/Rack-Mount 4U

Installation and Operation

Allen-Bradley. User Manual for 3000/5000 VA UPS. Tower/Rack-Mount 3U Uninterruptible Power Supply

Installation and Operation

POWERWARE User s Guide VA.

MM-AVR UPS Series User s Manual

Smart-UPS RC External Battery Pack Tower/Rack-Mount 4U

User Manual Easy UPS On-Line SRVS Series Rack-Mount 1000VA, 2000VA, 3000VA

User Manual. English. APC Smart-UPS. 7500/10000 VA VAC 6U Tower/Rack Mount Uninterruptible Power Supply B 02/2004

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

Installation and Operation

02/15/01. Powerware User s Guide VA.

POWERSTAR INC. Operations / Maintenance Manual Model: PS VA Tower UPS

PR1000ELCD / PR1500ELCD User s Manual

Uninterruptible Power System

UTILITY INPUT MAINS OUTLET

Allen-Bradley. User Manual for 8000/10000 VA UPS. Tower/Rack-Mount 6U Uninterruptible Power Supply

CP900EPFCLCD User s Manual K

Safety and General Information

Operation Manual. Smart-UPS Uninterruptible Power Supply. Rack-Mount 2U. 750/1000/1500 VA 120/230 Vac VA 120 Vac. 100/120/208/230 Vac

Installation and Operation

Installation and Operation Manual Smart-UPS Tower 220/230/240 Vac SRC1000ICCIND; SRC1000UXIND

Installation Guide Smart-UPS 1200/1500 VA 100/120/230 Vac Rack-Mount 1U

Power Inverter. Model BI800T and BI800F. w w w.apc.com. Installation Guide and User s Manual

Operation Manual. Smart-UPS Uninterruptible Power Supply. 1000/1500/2200/3000 VA 220 Vac. Rack-Mount 2U

Installation and Operation

w w w.apc.com Home Appliance & Lighting UPS HI800SQ Installation Guide and User s Manual

Uninterruptible Power System

Start UP Guide. Symmetra LX Tower Rack-Mount. UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

User Manual Smart-UPS On-Line SRC1KI-IN, SRC1KUXI

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

BroadBand PowerShield. 20 AHr Battery. User Manual

Liebert PSA VA. Installer/User Guide

Operation Manual. Smart-UPS Uninterruptible Power Supply. 750/1000/1500/2200/3000 VA 100/120/230 Vac. 500 VA 100 Vac. Tower

Operation and Maintenance

Operation Manual. Smart-UPS. Uninterruptible Power Supply VA Short-depth Rack-Mount with Lithium-ion batteries. 120 Vac

Electrical Installation

Operation Manual. Smart-UPS. Uninterruptible Power Supply. 750/1000/1500 VA Short-depth Rack-Mount with Lithium-ion batteries.

Installation Guide Smart-UPS On-Line External Battery Pack XBP48RM1U-LI

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

USER MANUAL MPS 1-5KW SERIES

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

SecureUPS On-Line 120V AC Output, 1300VA

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

Uninterruptible Power Supply

Uninterruptible Power System

Protection and conditioning against all forms of power anomalies.

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

Eclipse Plus VA UPS and Surge Suppressor User s Manual

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

400 Watt Backup Power System Owner s Manual

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

APC Smart-UPS Uninterruptible Power Supply Model 5000RMB User s Manual

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

Uninterruptible Power System. Line Interactive Network Protection Pure Sine Wave Output UPS. Rack Mount Models 1000VA/ 1500VA/ 2000VA/ 3000VA

Uninterruptible Power System

SmartPro Medical-Grade UPS, Line Interactive, Lithium Battery, 6 Outlets - 230V, 1kVA, 750W, Full Isolation

User Manual. PF0.9 1K/2K/3K Online UPS. Uninterruptible Power Supply System. Version: 1.3

Transcription:

Installation and Operation Manual Back-UPS BR1000-CH Complete, sign and return the Quality Assurance card or register the product online at www.apc.com. Safety This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with fluids, or where there is excessive dust or humidity. Do not operate this unit with aquarium equipment. Connect the Back-UPS power cord directly into a wall outlet. To avoid a fire hazard, connect this unit to circuits with maximum 20 A branch overcurrent protection. Do not use a surge protector or an extension cord. Product Overview Online Replace Battery bu043b bu188b

Installation Connect Power to the Back-UPS Plug the power cable into a 220 VAC wall outlet. Connect Equipment to Battery Backup Outlets Battery backup outlets provide protection to connected equipment when the Back-UPS is connected to utility power and turned on or off. Battery backup outlets receive power from the Back-UPS for a limited period of time when a power outage, or brownout condition occurs. Battery backup outlets provide protection from power surges and spikes. Connect a computer, monitor and other peripheral devices to the battery backup outlets. Connect Equipment to Surge Protection Outlets Surge protection outlets provide protection to connected equipment when the Back-UPS is connected to utility power and is turned on or off. Surge protection outlets provide protection from power surges and spikes. Connect a printer, FAX machine, scanner or other peripheral devices to the surge protection outlets. Operation Turn On the Back-UPS Press the Power On button located on the top of the Back-UPS. The Power On LED will illuminate and a single short beep will be audible, indicating that the Back-UPS is providing protection for connected equipment. To turn the Back-UPS off, press the Power On button. The Back-UPS battery charges during the first eight hours while connected to utility power. The battery will charge while the Back-UPS is connected to utility power and is turned on or off. 2 Installation and Operation Manual BR1000CH

Status Indicators Operation status of the Back-UPS is displayed by two LED indicators and several audible indicators. Indicator Description Low Battery Warning-The Back-UPS has two minutes of battery runtime remaining. Low Battery Shutdown-The battery is completely discharged. The Back-UPS will begin normal operation once utility power is restored. Replace Battery-The battery needs to be charged or replaced. Contact APC at apc.com for battery replacement information. Replace Battery- The battery is disconnected. Internal Fault Warning-The Back-UPS has an internal fault condition. Discontinue use of the Back-UPS. Contact APC at apc.com for support. Internal Fault Error-The Back-UPS has an internal fault condition. Discontinue use of the Back-UPS. Contact APC at apc.com for support. Battery Overload Condition-While operating on battery power an overload condition has occurred in one or more of the battery back-up outlets. Online Operation-Normal operation. The Back-UPS is supplying utility power to connected equipment. On Battery-The Back-UPS is supplying battery power to the battery backup outlets. Online Overload Condition-While operating on utility power an overload condition has occurred in one or more of the outlets. Online LED (green) Replace Battery LED (red) Audible Indicator LED flashes LED not illuminated The Back-UPS emits rapid beeping. LED not illuminated LED not illuminated The Back-UPS beeps every four seconds. The Online and Replace Battery LEDs flash green/red alternately. The Back-UPS emits a LED not illuminated LED flashes The Back-UPS emits a LED not illuminated LED not illuminated The Back-UPS emits a loud tone every two seconds. LED not illuminated LED not illuminated The Back-UPS emits a LED not illuminated LED not illuminated The Back-UPS emits a LED is illuminated LED not illuminated None LED flashes with each audible beep. LED not illuminated The Back-UPS beeps every four seconds. LED is illuminated LED not illuminated The Back-UPS emits a Installation and Operation Manual BR1000CH 3

Voltage Sensitivity Adjustment (optional) The Back-UPS detects and reacts to line voltage distortions by transferring to battery back-up power to protect connected equipment. In situations where either the Back-UPS or the connected equipment is too sensitive for the input voltage level, it is necessary to adjust the transfer voltage. 1. Connect the Back-UPS to a utility power source. The Back-UPS will be in Standby mode, no indicators will be illuminated. 2. Press and hold the Power On button for 10 seconds. The LED will illuminate alternately green/red, to indicate that the Back-UPS is in Program mode. 3. The LED will illuminate to indicate the current sensitivity level. Refer to the table for an explanation of the transfer voltage sensitivity levels. 4. To select LOW sensitivity, press and hold the Power On button until the LED flashes green. 5. To select MEDIUM sensitivity, press and hold the Power On button until the LED flashes red. 6. To select HIGH sensitivity, press and hold the Power On button until the LEDs flashes green/red simultaneously. 7. To exit Program mode wait five seconds and all LED indicators will extinguishes. Program mode is no longer active. LED Flashes Sensitivity Setting Input Voltage Range Recommended Use Green LOW 150 VAC to 266 VAC Input voltage is extremely low or (factory default) extremely high. Not recommended for computers. Red MEDIUM 176 VAC to 266 VSC Use when the Back-UPS frequently switches to battery operation. Flashes green/red alternately HIGH 176 VAC to 256 VAC Use when connected equipment is sensitive to voltage fluctuations. 4 Installation and Operation Manual BR1000CH

Specifications Input Output Protection and Filter Battery Physical Properties Voltage Frequency Low voltage transfer High voltage transfer UPS total output power Outlets Voltage - On Battery Frequency - On Battery Transfer time Utility power surge protection Utility input Type Average life Typical charge time Net weight Dimensions H x W x D Operating temperature Storage temperature Operating relative humidity Operating elevation 220 Vrms nominal 45 Hz - 65 Hz 150 Vrms typical 266 Vrms typical 1000 VA, 600 W Outlets for three prong Chinese plugs Two prong NEMA 5-15 plugs Four battery backup outlets Two surge protection outlets 220 Vrms ± 8% (step-approximated sine wave) 50 Hz ± 1 Hz to 60 Hz ± 1 Hz 5 ms typical, 8 ms maximum Always on, 310 Joules Resettable circuit breaker Two batteries. Sealed, maintenance-free, lead-acid, 12 V, 7 Ah 3-5 years depending on the number of discharge cycles and environmental temperature 8 hours 12 kg 22 cm x 13 cm x 34 cm 0º C to 40º C 5º C to 45º C 5% to 95% non-condensing 0 to 3,000 m Installation and Operation Manual BR1000CH 5

Troubleshooting Problem and Possible Cause The Back-UPS will not turn on The Back-UPS has not been turned on. Press the Power on button. Solution The Back-UPS is not connected to utility power, there is no utility power available at the wall outlet, or the utility power is experiencing a brownout or over voltage condition. Make sure the power cord is securely connected to the wall outlet, and that there is utility power available at the wall outlet. Where applicable, check that the wall outlet is switched on. Connected equipment loses power A Back-UPS overload condition has occurred. The Back-UPS battery is completely discharged. Remove all nonessential equipment connected to the outlets. One at a time reconnect equipment to the Back-UPS. Connect the Back-UPS to utility power and allow the battery to recharge for eight hours. The Back-UPS may require service. Contact APC Technical Support for more in depth troubleshooting. The Back-UPS is on, the Power On LED is illuminated and the unit emits a beep four times every 30 seconds The Back-UPS is operating on battery power. The Back-UPS is operating normally on battery power. At this point the user should save all open files, and shutdown the computer. When utility power is restored the battery will recharge. The Power On LED flashes and the Back-UPS beeps once every second The Back-UPS is operating on battery power. The Back-UPS is operating normally on battery power. There are approximately two minutes of runtime remaining. At this point the user should immediately save all open files, and shutdown the computer. When utility power is restored the battery will recharge. The Back-UPS has an inadequate battery runtime The battery is not fully charged. Operate the Back-UPS for 8 hours while connected to utility power. The battery should charge to full capacity during this time. The battery life cycle is near completion. As the battery ages the runtime capability decreases. To order a replacement battery contact APC at www.apc.com. Service If the unit requires service, do not return it to the dealer. Follow these steps: 1. Review Troubleshooting on page 6 of the manual to eliminate common problems. 2. If the problem persists, contact APC Customer Support through the APC Web site, www.apc.com. a. Note the model number and serial number and the date of purchase. The model and serial numbers are located on the rear panel of the unit and are available through the LCD display on select models. b. Call APC Customer Support and a technician will attempt to solve the problem over the phone. If this is not possible, the technician will issue a Returned Material Authorization Number (RMA#). c. If the unit is under warranty, the repairs are free. d. Service procedures and returns may vary internationally. Refer to the APC Web site for country specific instructions. 3. Pack the unit in its original packaging. If this is not available, refer to www.apc.com to obtain a new set. a. Pack the unit properly to avoid damage in transit. Never use foam beads for packaging. Damage sustained in transit is not covered under warranty. b. Internal batteries may remain connected in the XLBP during shipment, (if applicable, not all units have XLBPs). 4. Write the RMA# provided by Customer Support on the outside of the package. 5. Return the unit by insured, pre-paid carrier to the address provided by Customer Support. 6 Installation and Operation Manual BR1000CH

Replace the Battery Deliver the used battery to a recycling facility. Replace the used battery with an APC approved battery. Replacement batteries can be ordered through the APC Web site, www.apc.com. 1 Locate the battery compartment cover on the bottom of the unit. Slide the cover down. 2 Remove the battery from the compartment. Disconnect the battery cables from the terminals. Refer to the diagram below. Pack the used battery in the replacement battery packaging and recycle the battery properly. 3 To install a replacement battery, secure the battery cables to the terminals, black cable negative -, red cable positive +. Gently push the battery into the compartment. Ensure the battery cables are not under the battery nor crushed when the compartment cover is replaced.. 4 Replace the battery compartment cover. bu191a bu189a bu190a bu192a Contact APC Worldwide Support APC Web site, www.apc.com Telephone Support: 86 400 810 1315 Installation and Operation Manual BR1000CH 7

Customer support and warranty information is available at the APC Web site, www.apc.com. 2010 APC by Schneider Electric. APC, the APC logo, and Back-UPS are owned by Schneider Electric Industries S.A.S., American Power Conversion Corporation, or their affiliated companies. All other trademarks are property of their respective owners. 990-2239B 8/2010