FL 10 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS. Before operating the pump, please read the Installation Instructions and safety precautions.

Similar documents
FF 20 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS

DIAPHRAGM LIQUID PUMP NF 2.35

DIAPHRAGM LIQUID PUMP NF 1.30

DIAPHRAGM LIQUID PUMP NF 1.25

Swing Piston Compressors and Vacuum Pumps

LIQUIPORT DIAPHRAGM LABORATORY PUMP

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps

Micro Diaphragm Gas Sampling Pumps

Micro Diaphragm Gas Sampling Pumps

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

DIAPHRAGM LIQUID PUMP NF 10, NF 11, NF 1.11

DIAPHRAGM LIQUID PUMP NF 30, NFB 30

Micro diaphragm liquid pump NF 25 NFB 25

Micro diaphragm liquid pump NF 1.5 NFB 5

Swing Piston Compressors and Vacuum Pumps

Diaphragm-Gas Sampling Pumps

Diaphragm Vacuum Pumps and Compressors

DIAPHRAGM METERING PUMP FEM 1.02, FEM 1.09

Diaphragm Vacuum Pumps and Compressors

Operating and Installation Instructions Diaphragm Gas Sampling Pumps

Diaphragm Gas Sampling Pumps

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

Swing Piston Compressors and Vacuum Pumps

DIAPHRAGM LIQUID PUMP NF 100, NF 1.100, NFB 100

Diaphragm Vacuum Pumps and Compressors

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Diaphragm Vacuum Pump

DIAPHRAGM VACUUM PUMP

Instruction Manual. Sewage lifting station compli 300

Installation and Operating Instructions Electric Vibrators HV/VFL Series

Angle seat valve with diaphragm actuator VZXA-...-M

Angle seat valve with piston actuator VZXA-...-K

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Operating Instructions

Angle seat valve with piston actuator VZXA-...-K

ProFlo FatBoy

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Application cup for OptiFlex 2 GM03 manual powder gun

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual

Type 6213 EV, 6281 EV

Operating manual. Custom made gearboxes

INSTRUCTIONS FOR USE. Rx Only

Mod: KLD6-12/35XLAS-N

These installation and maintenance instructions must be read in full and completely understood before the installation!

Installation manual. Modbus Interface DIII EKMBDXA7V1. Installation manual Modbus Interface DIII. English

Industrial flue gas probes. Instruction manual

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

No.EX -OME0016-A PRODUCT NAME. SI unit. MODEL / Series / Product Number EX140-SDN1

Diaphragm Vacuum Pumps and Compressors

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Hydraulic PTO Flow Device

Lumitester PD-20 Control Kit

Air Operated Diaphragm Pumps Operating and Maintenance Instructions

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

OPERATING INSTRUCTIONS UNO/DUO 35/65. Rotary Vane Pump. Translation of the original instructions PK 0168 BEN/P (1604)

Installation Instructions for Load Management Kit A051C329

FLENDER ZAPEX couplings. Type ZWT. Operating instructions BA 3505 EN 10/2011. FLENDER couplings

Reflex ex separator. Exvoid / Exvoid HC (HiCap) Exdirt / Exdirt HC (HiCap) Extwin /Extwin HC (HiCap) Operating manual

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

Technical information for LFU20-Z07-3A-X2

HV angle valve with single acting pneumatic actuator and closing spring (NC)

Instruction Manual LAMI CORPORATION INC.

General operating manual for assembly, commissioning and maintenance of valves and hydraulic manifolds

Operating instructions Flow monitor SI / / 2014

NECO Pumping Systems

DLT-U1100 UPS Uninterruptible Power Supply Manual V1.00. Industrial PCs applied in

INSTRUCTION GREASE PUMP. PD110A50T MODEL No PD110A50T-SL MODEL No PD110A50 MODEL No DR110A50 MODEL No.

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Hydraulic Immediate Need Power Pack

Instruction Manual. * We reserve the right to amend specification without prior notice.

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Installation and Operating Instructions. Solar System Controller ISC3020

Magnetic Field Resistant 2-color Indication Type Solid State Auto Switch

Electronic pressure switch for air

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Internal Gear Pumps Installation Manual

Installation, Operating & Maintenance Instructions. HV angle valve with pneumatic actuator single acting with closing spring (NC)

Diaphragm Valves Type 15

Type 3571 Pneumatic Actuator. Actuator areas: 27 in² 54 in² 116 in². Original instructions. Mounting and Operating Instructions EB 8820 EN

DC-DC STEP DOWN CONVERTER CV 24/12V - 15 A Pro

Installation,Operation and Maintenance Manual H-V016-E-10. Serial No. 目次 ( ページ ) 1. Be sure to read the following warranty clauses of our product 1

Betriebsanleitung Operating Instructions. Oil Mist Filter

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

Ex m Solenoid Operator Type 0519

SLA Battery Capacity Analyzer

INSTRUCTION OIL PUMP. SH-110A5 MODEL No DR-110A5 MODEL No PD-110A5 MODEL No WARNING

Diaphragm Vacuum Pumps and Compressors

Hazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual

Read and understand this manual for safely usage.

Instruction Manual. Automatic Fuel Oil De-aerator Flow-Control. Flow-Control 3/K-1 # Flow-Control 3/K-2 # 70019

Operating Instructions

TBE-700. Operation, Safety and Maintenance Manual. Stainless Steel Weld Cleaning System. Ensitech Pty Ltd

Dome-Loaded Pressure Reducing BD-Series

HST -LS Interlocking device (Translation of Original Manual)

WPS600. Hydraulic Pressure Transducer. User s Guide. 600 bar 60 MPa 8700 psi

Tension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference!

MANUAL. Single charger

Transcription:

FL 10 INSTALLATION INSTRUCTIONS DIAPHRAGM PUMP FL 10 DC-P FL 10 AC Before operating the pump, please read the Installation Instructions and safety precautions.

Installation Instructions FL 10 Table of Contents Contents Page 1 General... 4 1.1 Information about the instructions 4 1.2 Warnings 4 1.3 Disclaimer 5 1.4 Manufacturer s address 5 1.5 Supporting documents 5 2 Safety... 6 2.1 Intended use 6 2.2 Reasonably foreseeable misuse 6 2.3 Responsibility of the user 6 2.4 Product-specific risks 6 3 Installation... 8 3.1 Installation location 8 3.2 Mechanical mounting 8 3.3 Connecting the fluid system 8 3.4 Electrical connection 9 4 Initial start-up... 10 5 Maintenance... 11 6 Rectifying transfer problems... 11 7 Returning the pump... 12 3

General Installation Instructions FL 10 Table of Contents 1 General 1.1 Information about the instructions The Installation Instructions describe the requirements for installing the product correctly and safely into the complete machine. Storage location These Installation Instructions are a part of the product. The safetyrelevant information should be taken over for the documentation of the complete machine. Project pumps With customer-specific project pumps (pump types which begin with "PL" or "PML"), there may be differences from the Installation Instructions. 1.2 Warnings Warnings in the Installation Instructions are marked by the hazard symbol, the keywords, and the color. These features provide information about the extent of the hazard. DANGER Indicates a dangerous situation, which will directly cause death or serious injury if not prevented. WARNING Indicates a dangerous situation, which may cause death or serious injury if not prevented. CAUTION Indicates a dangerous situation, which may cause moderate or slight injuries if not prevented. NOTICE Indicates a situation, which may cause damage to property if not prevented. 4

Installation Instructions FL 10 General 1.3 Disclaimer The manufacturer accepts no liability for damage or malfunctions that are caused by non-compliance with the Installation Instructions. The manufacturer accepts no liability for damage or malfunctions that are caused by modifications to or conversions of the device or by improper handling. The manufacturer accepts no liability for damage or malfunctions that are caused by using spare parts or accessories that are not approved by the manufacturer. 1.4 Manufacturer s address KNF Flodos AG Wassermatte 2 6210 Sursee, Switzerland Phone +41 (0)41 925 00 25 Fax +41 (0)41 925 00 35 www.knf.com 1.5 Supporting documents The listed documents must also be observed. The valid versions are available on www.knf.com/downloads. Data sheet 3D model Further attention must be paid to: Local T&Cs Sales documents and agreement between KNF and the customer 5

Safety Installation Instructions FL 10 2 Safety 2.1 Intended use The pump is intended solely for the following uses: Transferring liquids and gases For operation in accordance with the operating parameters specified in the technical data of the supporting documents 2.2 Reasonably foreseeable misuse The pump must not: be operated in an explosive atmosphere be used to transfer explosive media be used to transfer media whose compatibility with the pump head, valves, diaphragms, and seals has not been proven 2.3 Responsibility of the user The user is responsible for ensuring that the safety precautions in these Installation Instructions are complied with. Applicable, safety, accident prevention, and environmental protection regulations must be complied with. 2.4 Product-specific risks Remaining risks that were determined in a risk assessment are described in this section. Safety precautions and warnings in this section and in the other sections of the Installation Instructions must be observed to prevent dangerous situations. DANGER Danger of injuries and damage to property due to dangerous substances Poisoning and chemical burns or unintended reactions caused by leaking dangerous substances Observe the safety data sheets of the transferred media Ensure the pump is used only by suitably trained, skilled employees Clarify the wear resistance of the head material Check the pump and the system for leaks Regularly check the pump for damage Operate the pump only when you are sure it has no technical malfunctions Operate the pump in accordance with the technical data Work on the pump or fluid circulation system only after they have been decontaminated and/or a decontamination declaration is present 6

Installation Instructions FL 10 Safety DANGER Danger of injuries and damage to property due to leaks at the interfaces to the pump head Poisoning and chemical burns or unintended reactions caused by leaking dangerous substances Wear personal protective equipment Connect the pump correctly Operate the pump only when you are sure it has no technical malfunctions Operate the pump in accordance with the technical data DANGER Danger of injuries and damage to property due to uncontrolled flow while the pump is not in operation Poisoning and chemical burns or unintended reactions caused by leaking dangerous substances Install a shut-off valve in the fluid circulation system WARNING Danger from magnetic field The pump generates a strong local magnetic field, which may cause pacemakers or other devices that are affected by magnetic fields to malfunction. Ensure that these devices are kept at least 10 cm away from the pump when it is operating If necessary, attach additional shielding devices 7

Installation Installation Instructions FL 10 3 Installation WARNING Danger from incorrect installation Injuries or damage to property from leaking media After installation, check the system for leaks with a safe medium Observe the requirements for intended use The following requirements apply to all activities described in this section: 3.1 Installation location The installation location must: protect the pump against immersion keep aggressive and flammable liquids and vapors away allow hoses to be connected without tensile or bending stress take account of cooling the pump drive ensure that any leaks can be handled have appropriate precautions if flammable media are used 3.2 Mechanical mounting Protect the product against impacts, knocks, and strong vibrations For dimensions, installation positions, fluid connections, please refer to the product data sheet 3.3 Connecting the fluid system Use suitable means to check the fluid connection for leaks. For more information regarding dimensions, please refer to the data sheet. 8

Installation Instructions FL 10 Installation 3.4 Electrical connection For terminal assignment, output data, and control requirements, please refer to the data sheet Observe the regulatory requirements for electrical installations: Overload protection and separating protective devices Contact protection and additional insulation Ground connections Protection against vibrations, tensile stress, and corrosion 3.4.1 DC coils CAUTION Danger from burns or fire, poisoning from flue gases If the pump is connected incorrectly, it may overheat and catch fire. Connect the pump to the correct voltage Operate the pump in accordance with the technical data Take suitable precautions to limit maximum power consumption. 3.4.2 AC coils DANGER Danger from electric shock Connect the pump to the correct voltage Wear personal protective equipment Operate the pump only when you are sure it has no technical malfunctions Operate the pump in accordance with the technical data In case of a malfunction, leaking medium must not come into contact with live components Ensure that the fluid circulation system is grounded Check the pump for damage regularly Disconnect the pump from the power supply when carrying out maintenance work In case of fixed installation, install a maintenance switch Installation only by trained, skilled personnel who have knowledge of the applicable international regulations Ensure contact protection for live parts (persons, cable, and device protection) 9

Initial start-up Installation Instructions FL 10 4 Initial start-up The product must not be started up until it has been ensured that the machine in which the product is to be installed meets the requirements of the Machinery Directive 2006/42/EC, if applicable. CAUTION Danger that the fluid system could rupture due to excess pressure The pump builds up pressure. With a closed system, the max. permitted operating pressure may be exceeded, which can damage the pump and the system. Prevent operation against a closed system Use only parts that come into contact with the fluid that are designed to at least withstand the operating pressure of the pump If necessary, take suitable measures to limit the maximum system pressure CAUTION Danger of unexpected chemical reactions with water Residues of water in the pump that come from testing in the factory may react with the transferred medium. Before starting the pump for the first time, rinse it with a medium that is uncritical as regards water CAUTION Danger from hot surfaces The pump becomes hot during operation Burns from hot surfaces or injuries from uncontrolled movements are possible. Do not touch the pump while it is operating. Ensure a sufficient supply of cool air and keep a safe distance between the pump and neighboring components. Operate the pump in accordance with the technical data If the temperature of the medium is above 50 C, take precautions to prevent burns from fluid components. Before switching on the pump, check the following points: All hoses attached properly Specifications of the power supply correspond with the data on the pump s type plate Pump discharge not blocked All cables attached properly Contact protection for electrical connections and moving parts installed 10

Installation Instructions FL 10 Maintenance 5 Maintenance This product contains no parts that can be replaced and it cannot be maintained. 6 Rectifying transfer problems Symptom Cause Remedy Pump does not work, no movement or sounds detectable No or incorrect control Check that voltage and signal form comply with the specification Pump does not work, drive is very hot The pump does not suck or vacuum is insufficient Pump does not transfer Flow rate is insufficient or unstable Leak of pump head The coil is controlled with DC voltage or another, incorrect signal form External valve is closed Counter pressure on pressure side is too high Particles in the pump head External valve is closed or filter is clogged or too small Connections or hoses are blocked Incorrect control Cross-section of hydraulic hoses or connectors too narrow or restricted Higher counter pressure in the system than assumed for the design Particles in the pump head Pump has reached the end of its service life Diaphragm or oscillating diaphragm defective Check that voltage and signal form comply with the specification Check external valve Change the pressure conditions on the pressure side Rinse the pump head Use a preventive preliminary filter Check external valves and filter Check connections and hoses Remove blockage. Check that voltage and signal form comply with the specification Disconnect the pump from the system and determine output values Remove restriction (e.g. valve) if necessary. If applicable, use larger-diameter hoses or connectors Contact KNF representative Rinse the pump head Use a preventive preliminary filter Replace the pump Replace the pump If the malfunction cannot be rectified, contact your local KNF representative (www.knf.com) 11

Returning the pump Installation Instructions FL 10 7 Returning the pump 1. Rinse the pump to remove dangerous and aggressive liquids from the pump head. 2. Dismantle the pump 3. Send the pump with completed decontamination declaration (see www.knf.com/download) to KNF. 12

www.knf.com