Adjustable Dead Band Pressure Switches

Similar documents
Adjustable Dead Band Pressure Switches

Dual Hi-Lo Pressure Switches

Dual Hi-Lo Pressure Switches

Dual Hi-Lo Pressure Switches

Mini-Hermet Pressure Switches

Dual Hi-Lo Pressure Switches

Mini-Hermet Pressure Switches

Mini-Hermet Pressure Switches

Mini-Hermet Pressure Switches

Big Hermet Pressure Switches with Hermetically Sealed Switching Elements

101/121 Differential Pressure Switches

102/103 Differential Pressure Switches

Pivot Seal Pressure Switches

Pressure and Vacuum Switches for Process Applications

Pressure and Vacuum Switches for Process Applications

Pressure and Vacuum Switches for Process Applications

Pivot Seal Pressure Switches for Fluid Power Applications

Pressure Switch SOR. Sifter ready to run: Adequate pressure to switch. Sifter not ready to run: Either loss of air pressure, or open guard.

Pressure and Vacuum Switches for Process Applications

Big Hermet Pressure Switches

2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device

Temperature Switches. General Instructions

103 Differential Pressure Switch

Opposed Piston Differential Pressure Switches

101/121 Differential Pressure Switches

102 Differential Pressure Switch

UNITED ELECTRIC 100 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches Adjustable Ranges 30 Vac to 5000 PSI, -180 to 650 o F

rugged, reliable problem solvers

B Temperature Switches

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Mid-West Instrument. Diaphragm Type Differential Pressure Gauge & Switch Model 130. Shown here with Range 0-5 H2O

1500 Series Level Switches

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

INSTALLATION AND OPERATION MANUAL

PISTON STYLE GAUGE. Mid-West Instrument

Quick Reference Charts

E. Clark & Associates 10 Brent Drive Hudson, MA Tel. 978 / Fax 978 / Two Switch Output Hex Screw Adjustment

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 120

PISTON STYLE GAUGE. For Installation and Operation Manuals Please Visit: Mid-West Instrument

9012G Pressure and 9016G Vacuum Switches

Pressure Controller. Cataloge K Code Characteristics Index. K00-2 Pressure Controller Brief Introduction

Opposed Piston Differential Pressure Switches

^ % P-SERIES Temperature Switches. Switches for -30 through 510 F with Adjustable Set Points and Fixed or Adjustable Deadband

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

Mini pressure switch Stainless steel switch enclosure Model PXS

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 123

VACUUM A RESOURCE FOR EVERYONE

Pivot Seal Pressure Switches for Fluid Power Applications

Compact pressure switch Model PCS

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

Data Sheet. A-Series Miniature Watertight Pressure Switches

PRESSURE, VAcuum, DIFFERENTIAL PRESSURE,

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 124

Data Sheet. A-Series Miniature Watertight Pressure Switches. Factory set or field adjustable

SPANS AND RANGES. Lower Range Limits 150 in. H 2 O ( 38 kpa) 800 in. H 2 O ( 200 kpa)

MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES,

M-100 Adjustable flow switch with right-angle flow

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter. Min.

Compact differential pressure switch Models DC, DCC

RF Point Level Control with Sensor Monitor

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL

Flow meters, Flow switches and Flow transmitters

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 122

Opposed Piston Differential Pressure Switches

Swagelok Ball Valve Actuation Options

Quartz. Save Space with Low Profile Design

Ultrasonic Two-Wire Point Level Control

UNIVERSAL Flow Meters

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

FM8 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

M-100X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

short form catalog SFC 07

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with General Purpose, Watertight or Explosion-Proof Enclosures

Product Information Page

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

INTERNATIONAL METAL ENGINEERING

Compact temperature switch Model TCS

Technical Datasheet. GR Series - Flameproof Pressure Switch Models: GR2 & GR4. GR Series. Key Features. Series Overview. Product applications

The T5220 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

Mid-West. Instrument ELECTRICAL DIVISION 1 LOCATIONS:

Electropneumatic Timing Relays Series 7000 Industrial

Control Without Compromise. Suitable for use in hot, cold, wet, dirty, abusive, corrosive, and explosive environments

Ultrasonic Two-Wire Point Level Control with Tip-Type Sensor

Diaphragm Type Differential Pressure Gauges Switches & Transmitters Model 140

How a wide range DUAL SNAP pressure switch works

Rosemount Product Data Sheet , Rev GA Catalog FIELDBUS PROTOCOL. Hazardous Locations Certifications

INTERPLANT STANDARD - STEEL INDUSTRY. Specification for Smart Pressure & Differential Pressure Transmitter

Model 5000 Level Controller

Fisher 3710 and 3720 Positioners and 3722 Electro Pneumatic Converter

O.E.M GAUGES. For Installation and Operation Manuals Please Visit: Mid-West Instrument

Size: 1/4 to 3. Material: 316 Stainless Steel, Carbon Steel,

Shuttle Type Switches For Moderate to High Liquid Flow Rates

FM9 Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...

Valve Position Monitors

VA-640GSX024P. Overview. Applications. Features & Benefits. Datasheet. Large Globe Valve Actuators

Transcription:

The adjustable dead band pressure switch should be used when there is a requirement for an adjustable and wide dead band between the increasing and decreasing set points. Function Alarm: Hi Lo Control: On Off V1 Weathertight Housing Design and specifications are subject to change without notice. For latest revision, see. V3 Weathertight Explosion Proof Hermetically Sealed Switches Features and Benefits 3-year warranty from date of manufacture Wide adjustable dead band Independent adjustments for increasing and decreasing Set Points Field adjustable with fine resolution of Set Points Instrument quality high repeatability High overrange and proof pressures Exceptionally long life Not critical to vibration Wide selection of wetted parts materials for process compatibility and containment Phone 913-888-2630 Registered Quality System to ISO 9001 /16

Principle The SOR Adjustable Dead Band pressure switch incorporates two industry proven Static O Ring pressure sensing elements. Media pressure on the areas of the pistons counteracts the forces of the range springs each adjustable by a separate adjusting nut and moves the piston shafts to operate the lever assembly which, in turn, actuates and deactuates the electrical switching element. Each pressure sensing element of the Adjustable Dead Band pressure switch is a force balance piston-actuated assembly sealed by a flexible diaphragm and an o-ring that is static. The only wetted parts are the single pressure port, two diaphragms, and two o-rings all indicated with asterisks (*) in this illustration. Electrical Switching Element (Explosion Proof Model has Hermetically Sealed Switching Element Capsule) Screw Terminal Block (Weathertight Model Only) Calibration Scale Increasing Set Point Adjusting Nut Housing Piston Assembly Pressure Range Spring *Diaphragm *O-Ring *Pressure Port *O-Ring Lever Assembly Calibration Scale Decreasing Set Point Adjusting Nut Piston Assembly Pressure Range Spring *Diaphragm Principle Schematic The lever assembly travel illustrated here has been exaggerated for clarity. No Pressure: Electrical switching element is deactuated. Actuation Pressure greater than decreasing Set Point but less than increasing Set Point. Electrical switching element remains deactuacted. Deactuation Pressure equal to or greater than increasing Set Point: Electrical switching element is actuated. Pressure less than increasing Set Point but greater than decreasing Set Point: Electrical switching element remains actuated. /16 Registered Quality System to ISO 9001 Pressure equal to or less than decreasing Set Point: Electrical switching element is deactuated.

How to Order Model Number System 6V1-LA3-N6-C1A-YY Housing Switching Diaphragm Pressure Port Accessories Element How to Order Information and data in this catalog are formatted to provide a convenient guide to assist instrument engineers, plant engineers and end users in selecting pressure switches for their unique applications. Steps 1 through 5 are required. Step 6 is optional. Orders must have complete model numbers, i.e. each component must have a designator. Step 1: Select Adjustable Range from pages 4, 5 and 6 to fill in and. Step 2: Select Housing. Weathertight or explosion proof/weathertight (page 6). Step 3: Select electrical Switching Element for electrical service (page 7). Step 4: Select Diaphragm and O-Ring for process compatibility and containment (page 8). Step 5: Select Pressure Port for process compatibility and connection (page 9). Step 6: Select Accessories required for service (page 9). If Agency Approved, Certified or Listed pressure switches are required, see page 10 for components that must be specified. Registered Quality System to ISO 9001 /16

Step 1: Adjustable Range 5V1-LA3-N6-C1A-YY Six adjustable dead band ranges are available. Each adjustable range is displayed on a grid (pages 5 and 6). Determine the correct adjustable range for the application by checking increasing and decreasing Set Point requirements against the tables. In the example below, a contact closure is required when pressure increases to 160 psi. The same contact must open when pressure decreases to 60 psi. Since 60 psi is within the blue field, the example grid range is correct for the application. When the correct range grid is selected, insert range designators and from that grid into the model number. Step 1 Find the specified increasing Set Point at the top of the graph. Increasing Set Point (PSI) 80 100 120 160 200 200 240 5-3 Step 2 Find the specified decreasing Set Point along the left edge of the graph. Decreasing Set Point (psi) 160 120 80 40 20 Step 3 Following the vertical line down from the increasing Set Point. Follow the horizontal line across from the decreasing Set Point. Any point within the blue field is acceptable. 0 1 5 2 3 5V1-LA3-N6-C1A-YY 1st and 4th places in model number /16 Registered Quality System to ISO 9001

Step 1: Adjustable Range 5V1-LA3-N6-C1A-YY Increasing Set Point (psi) Increasing Set Point (psi) 5 9 13 17 22 21 25 80 20 30 40 60 80 100 Decreasing Set Point (psi) 18 14 10 80 6 40 Overrange 750 psi 50 bar Proof 1000 psi 70 bar Decreasing Set Point (psi) 60 40 20 Overrange 1500 psi 100 bar Proof 2500 psi 170 bar 2 10 0 4 4 1 2 0 6 3 1 2 Decreasing Set Point (psi) 160 120 80 40 20 0 Increasing Set Point (psi) 80 100 120 160 200 Overrange 1500 psi 100 bar Proof 2500 psi 170 bar 5 3 1 2 240 Decreasing Set Point (psi) 150 200 250 350 350 300 200 100 50 0 Increasing Set Point (psi) Overrange 2500 psi 170 bar Proof 3875 psi 267 bar 9 4 1 2 450 Registered Quality System to ISO 9001 /16

Step 1: Adjustable Range 5V1-LA3-N6-C1A-YY Increasing Set Point (psi) 300 400 600 800 1000 Increasing Set Point (psi) 600 900 1200 1500 1500 1750 Decreasing Set Point (psi) 600 400 200 100 0 Overrange 2500 psi 170 bar Proof 3875 psi 267 bar 9 5 1 2 Decreasing Set Point (psi) 1200 900 600 300 200 100 0 Overrange 2500 psi 170 bar Proof 3875 psi 267 bar 9 45 1 2 Step 2: Housing 6V1-LA3-N6-C1A-YY Service Description Designator Non-Hazardous Locations Hazardous Locations (UL Listed/CSA Certified, ATEX and SAA Approved Snap Switch) Weathertight for non-hazardous service. NEMA 4, 4X & IP65 Electrical conduit connection: 3/4 NPT(F) Material: 356 aluminum Use LA or SA switching element and terminal block. Shipping weight: 4 pounds (2 kgs) See cutaway view on page 2; dimensions on page 14. Explosion proof and weathertight. NEMA 4, 4X & IP65. Class I, Group A, B, C, D; Class II, Group E, F, G; Division 1 & 2 Electrical conduit connection: 3/4 NPT(F) Material: 356 aluminum Use AG switching element; hermetically sealed SS capsule Shipping weight: 5 pounds (2.5 kgs) V1 V3 6/16 Registered Quality System to ISO 9001

Step 3: Switching Elements 6V1-LA3-N6-C1A-YY Switching Element Service Contact Form Electrical Connection Type AC Rating DC Rating Resistive Maximum Ambient Temperature Designator Volts Amps Volts Amps Volts Amps Deg F Deg C SPDT DPDT Normal Service AC Very High Capacity DC Magnetic Blow-out SPDT Screw Terminal Block 250 15 125.5 30 10* 180 80 LA N/A 125 10 125 1.5 Minimum 10.0 Maximum - - 180 80 SA N/A AC or DC DPDT 18 18 AWG color-coded wire leads 3/4 NPT(M) conduit connection 250 11 125.5* 30 5.0 160 70 N/A AG 1. The switching elements shown above are UL Listed and CSA Certified. The DC current rating marked (*) is not UL Listed but has been verified by testing and/or experienced. 2. The hermetically sealed switching element capsule is UL Listed, CSA Certified, ATEX and SAA Approved as a snap switch in accordance with the following table. Agency Hazardous Location Condition Designator UL Listed Class I, Group A, B, C, D; CSA Certified Class II, Group #, F, G; Division 1 & 2 Ex x IIC T6 for Class 1, Zone 1 AG SAA Note 3 DIP Type B 80 C for Class II, Approved Division 1 & 2 ATEX Approved II 2 G EEx m II 3. Consult the factory for availability of SAA Approved units. Registered Quality System to ISO 9001 /16

Step 4: Diaphragm and O-Ring 6V1-LA3-N6-C1A-YY Notes 1. N4 diaphragm system is standard. It is normally suitable for air, oil, water and non- corrosive processes. 2. Other diaphragm and o-ring combinations may be available. Consult the factory or the SOR representative in your area for more information. 3. Wetted parts have been selected as representing the most suitable commercially available material for use in the service intended. However, they do not constitute a guarantee against corrosion or permeation, since processes vary form plant to plant and concentration of harmful fluids, gases or solids vary from time to time in a given process. Emperical experience by users should be the final guide. Alternate materials based on this are generally available. 4. Specify N3 diaphragm system for high cycle rate, high shock applications where Buna-N and TCP are compatible with the process. 5. This table shows allowable minimum and maximum temperature for o-rings. O-Ring Material F C 32 to 400 0 to 204 GLT -20 to 400-29 to 204 Kalrez* 5 to 400-15 to 204 Aflas 25 to 400-4 to 204 Buna-N Neoprene EPR -30 to 200-34 to 93 TCP-Teflon Coated -30 to 400-34 to 204 Polyimide Diaphragm *Kalrez or equivalent Perfluoroelastomer (FFKM) o-rings 6. M9 diaphragm system is suggested for steam applications up to 400 o F. 7. Dead bands are slightly higher when using H, J, W, N3, or N6 series diaphragm options. Consult the factory. O-Ring (Wetted) Kalrez Kalrez Kalrez Kalrez GLT Buna-N Neoprene Kalrex Aflas Diaphragm (Wetted) Monel Hastelloy-B Hastelloy-C Carpenter-20 316L SS Designator A4 A6 H4 H6 J4 J6 L4 L6 M1 M2 M4 M5 M7 M8 EPR M9 (See Note 6) N1 Buna-N Buna-N TCP Teflon-Coated Polymide N3 (See Note 4) N4 Standard (See Note 1) N5 Kalrez Kalrez Kalrez N6 EPR Aflas TCP Teflon-Coated Polymide N7 N8 Buna-N Buna-N P1 Neoprene Neoprene R1 S1 GLT S2 Buna-N W2 W4 Tantalum Neoprene W5 Kalrez W6 EPR Ethylene Propylene EPR Ethylene Propylene Y1 /16 Registered Quality System to ISO 9001

Step 5: Pressure Port 6V1-LA3-N6-C1A-YY Material Connection Designator Aluminum Alloy 356 copper-free casting 316SS CF-8M Casting 1/4 NPT(F) B1A 1/2 NPT(F) B2A 1/4 NPT(F) C1A 1/2 NPT(F) C2A Step 6: Accessories 6V1-LA3-N6-C1A-YY Accessory / Option & Description Wetted parts are cleaned for industrial oxygen service. CSA Certified pressure switch. Available with V1 housing. Housing has earth (ground) lug. See agency listings on page 10 for details. Cemented cover gasket on weathertight housing. Universal terminal box, 1/2 NPT(F). 316SS. Explosion proof. FM Approved; CSA Certified. See form 657 (Catalog GI-30). Vacuum protector plate. Retains diaphragm in pressure switch if subjected to vacuum greater than 15 in. Hg. Material matches or exceeds pressure port material. Compliance to NACE Certification MR0175. Stainless steel piston and cylinder disc for higher overrange and proof. Consult the factory. Pipe (stanchion) mounting kit for (1-1/2 to 2 pipe). Order as a separate line item for CSA Certified pressure switches. Tag, fiber. Attached with plastic wire to housing. Stamped with customer-specified tagging information. Tag, stainless steel. Attached with stainless steel wire to housing. Stamped with customer specified tagging information. (2 lines, 18 characters and spaces per line.) Explosion proof and weathertight electrical junction box with screw termianls. 3/4 NPT(F) top or right conduit connections as required. UL Listed and CSA Certified Class I, Groups A, B, C & D; Class II, Group E, F & G; Division 1 & 2. Includes cover o-ring for weathertight applications. (V3 housing only.) Oversize stainless steel nameplate. Permanently attached to housing. Stamped with customer specified tagging information Fungicidal varnish. Covers exterior and interior except working parts. Epoxy coating. Exterior only. Polyimide epoxy with 316SS pigment. Chained cover with captive screws to conform to former JIC specifiction. X is used as a suffix to the model number for special reqirements not keyed elsewhere in the model number by an X. Each X must be completely identified in the text of the order or inquiry. When more than one X is required, use X followed by the number of such items. For example, X3 means three separate, otherwise unidentifiable requirements. Designator BB CS GC HT MM NC PC PK PP RR TB TT VV YY ZZ X Registered Quality System to ISO 9001 9/16

Agency Listings The following combinations only are available as approved, certified or listed by the agencies shown. Some components are for products not offered in this catalog. Certain components or combinations may acquire additional approval, certification or listing between print dates of this catalog. Contact the factory for the most current information. CSA Enclosure 4 (Weathertight) Piston Housing Switching Element Spring Diaphragm & O-Ring Pressure Port Material & Connection Size All V1 LA, SA All All All Accessories/ Option CS Required All except TB 10/16 Registered Quality System to ISO 9001

Glossary of Terms SOR recognizes that there is no industry convention with respect to terminology and definitions pertinent to pressure switches. This glossary applies to SOR. Adjustable Range The span of pressure between upper and lower limits within which the pressure switch can be adjusted to actuate/deactuate. Dead Band The difference in pressure between the increasing Set Point and decreasing Set Point. Decreasing Set Point That discrete pressure at which the pressure switch is adjusted to deactuate on falling pressure. It must fall within the adjustable range. Hermetically Sealed A welded steel capsule with glass-to-metal, factory-sealed, electrical leads that isolates the electrical switching element(s) from the environment. Increasing Set Point That discrete pressure at which the pressure switch is adjusted to actuate on rising pressure. It must fall within the adjustable range. Overrange The maximum input pressure that can be continuously applied to the pressure switch without causing permanent change of Set Point, leakage or material failure. Pressure Switch A bi-stable electromechanical device that actuates/deactuates one or more electrical switching element(s) at a predetermined discrete pressure/vacuum (Set Point) upon rising or falling pressure/vacuum. Proof Pressure The maximum input pressure that can be continuously applied to the pressure switch without causing leakage or catastrophic material failure. Permanent change of Set Point may occur, or the device may be rendered inoperative. Repeatability The ability of a pressure switch to successively operate at a Set Point that is approached from a starting point in the same direction and returns to the starting point over three consecutive cycles to establish a pressure profile. The closeness of the measured Set Point values is normally expressed as a percentage of full scale (maximum adjustable range pressure). SPDT Switching Element Single-Pole, Double Throw (SPDT) has three connections: C Common, NO Normally Open and NC Normally Closed, which allows the switching element to be electrically connected to the circuit in either NO or NC state. DPDT Switching Element DPDT is two synchronized SPDT switching elements which actuate together at increasing Set Point and deactuate together at decreasing Set Point. Discrete SPDT switching elements allow two independent circuits to be switched; i.e., one AC and one DC. The synchronization linkage is factory set, and is not field adjustable. Synchronization is verified by connecting test lamps to the switching elements and observing them go On simultaneously at actuation and Off simultaneously at deactuation Registered Quality System to ISO 9001 11/16

Dimensions Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certified drawings for a particular model number. Dimensions are expressed as millimeters over inches (Linear = mm/in.). Switch Mounting Holes (Typical 4) 11.9 0.47 71.4 2.81 95.3 3.75 Holes for 5/16 Diameter Mounting Hardware Furnished with U-Bolts for Mounting to 1-1/2 to 2 Pipe 71.4 2.81 31.0 1.22 Pressure Port Side C Switch Mounting Holes L 133.4 5.25 40.5 1.59 7.4 0.29 50.8 2.00 (Pipe Reference) Drawing # 0090300 Pipe Mounting Kit: PK Perpendicular Mounting Parallel Mounting 141.2 5.56 70.6 2.78 (Typical) 7.9 0.31 Diameter (2 Places) 93.7 3.69 22.4 0.88 9.9 0.39 *167.1 6.58 3/4 NPT(F) Electrical Connection (3 Places) 78.5 3.09 (Typical) 3/4 NPT(M) Close Nipple Attached to Standard 3/4 NPT(F) Electrical Conduit Connection *Dimension shown is approximate and based on a 5-thread engagement. Drawing # 0091353 Junction Box with Terminal Block: TB 12/16 Registered Quality System to ISO 9001

Dimensions HT and HB: 1/2 NPT(F) HBME: M20 x 1.5 (F) Remove Cover for Screw Terminal Access 108.0 4.25 54.0 2.13 Cover Locking Screw 89.4 3.52 69.9 2.75 2.4 0.09 Instrument Connection 43.6 1.72 58.6 2.31 Drawing # 0090763 Junction Box with Terminal Block: HT Dimensions shown are for reference only. Contact the factory for certified dimension drawings. Shipping Weights V1 Housing V3 Housing 4 lbs (2 kgs) 5 lbs (2.5 kgs) Accessory Add lbs kgs PK Pipe Kit 1.5 0.7 TB Junction Box with Terminal Block 5 2.25 Actual shipping weights may vary from the charted values because of product material, configuration and packaging requirements. Registered Quality System to ISO 9001 13/16

Housing Dimensions Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certified drawings for a particular model number. Dimensions are expressed as millimeters over inches (Linear = mm/in.). 138.9 5.47 69.6 2.74 Electrical Connection 3/4 NPT(F) 26.2 1.03 *185.7 7.31 9.7 0.38 *70.4 2.77 9/32 Diameter Mounting Holes (Typical 2) Drawing # 0090236 Non-Hazardous Locations Weathertight NEMA 4, 4X, IP65 Housing Designator: V1 57.2 2.25 Pressure Port 114.3 4.5 70.1 2.76 27.7 1.09 *Add 6.4 for all non-aluminum ports. 0.25 138.9 5.47 69.6 2.74 Electrical Connection 3/4 NPT(F) (Factory Sealed Wire Leads) 26.3 1.03 *217.4 8.56 *70.4 2.77 9/32 Diameter Mounting Holes (Typical 2) 114.3 4.50 57.2 2.25 Pressure Port 70.1 2.76 Drawing # 0090325 *Add 6.4 for all non-aluminum ports. Hazardous Locations 0.25 Contains Explosion Proof, Hermetically Sealed Switching Element Capsule: UL Listed, CSA Certified, ATEX and SAA Approved Housing Designator: V3 27.7 1.09 14/16 Registered Quality System to ISO 9001

Notes Registered Quality System to ISO 9001 15/16

SOR offers a full line of commercial-grade process instruments. echosonix Level Transmitters Level Switches Level Temperature Switches Pressure Temperature Pressure Switches Flow Switches Flow Process Instrumentation We Deliver Quality On Time SOR Inc. 14685 West 105th Street Lenexa, Kansas 66215 Toll Free 800-676-6794 Fax 913-888-0767 Registered Quality System to ISO 9001 16/16 Registered Quality System to ISO 9001 (04.06) 2006 SOR Inc.