System Simplicity Design, Install, Maintain

Similar documents
Midea VRFs/ Midea V5X. Timothy Huang Senior Engineer

Ductless. MRV-S (Mini VRF) Product Brochure. Higher Comfort, Haier Living. rev 01/01/2018

Owner s Information Manual

Air filter. Attention

Ductless Split Systems

SUBMITTAL COVER SHEET

DPLS2 MANUFACTURED FOR: MITSUBISHI ELECTRIC US, INC. Drain Pan Level Sensor/Control. for use with:

modular multi intelligent, environmental and versatile

Ductless Split Systems

Jeep Wrangler TJ. Complete Air Conditioning System. Slide Control Head. Installation instructions

Installation handbook

New ECOi Electric 2 and 3 pipe VRF systems. 2006/7 Range. All round air conditioning by

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

Ductless Split Systems

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

11. Installation Instruction

VRF. For Commercial and Light Commercial

LANDMARK. Commercial Packaged Rooftop Units Standard- and High-Efficiency 2- to 25-Ton KG/KC/KH/KHB and KH/D**B/M Models

INSTALLATION, OPERATION & MAINTENANCE INSTRATIONS

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

Submersible Mixed Flow/Axial Flow Pump Model SAM Model SPM

Product Data. Features/Benefits. 38HDL Cooling Only Condensing Unit. 1 1 / 2 to 5 Nominal Tons

Specification Approval Sheet

Air Conditioner. Installation manual. Wired remote controller MWR-WE11N

Zip FlushMaster Solo Water Saver Urinal Flushing System Keeps Urinals Clean & Reduces Water Wastage

HS17. HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw ( to Btuh) Cooling Capacity. MATCHED REMOTE SYSTEMS 50hz ENGINEERING DATA

A B 0 0 C D E 6 7 G F F H 8 9 K M O O L N I J 1

Checkup. Make. Signature. Date. Company Stamp: com


TECHNICAL SPECIFICATIONS

INSTALLATION INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS. Air Boss MP600M Vertical Air Flow Mist Precipitator Industrial Applications. TRION

AFFORDABLE DUCTLESS SOLUTIONS FROM AMERISTAR

COMFORT FOR LIFE DUCTLESS WALL & FLOOR MOUNTED HIGH-EFFICIENCY HEAT PUMP 20 SEER UP TO 12.5 HSPF UP TO 13 EER INVERTER, VARIABLE-SPEED COMPRESSOR

Exhaust Gas Recirculation Valve, Replace J S file://c:\program Files\cosids\DATA\TMP\ rtf.html. Remove

SUBMITTAL COVER SHEET

P5RF Series Single Packaged Air Conditioner Single Phase

Safety Notices. Dear user, thank you for choosing a HOUGHTON caravan air-conditioner. For your

Instructions for Installing the Vi p e r Si g n a l Ma s t e r with Brake Module

6. Document tasks performed during visit and report any observations to the appropriate

Installation Manual. Remote Temperature Sensor KS9-BS1-A. Instructions for :- Remote Temperature Sensor

DLC4AV09J1A DLC4AV18K1B DLC4HV09J1A DLC4HV12J1A 1 DLC4HV12K1A 1 DLC4HV18K1A DLC4HV30K1A

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

GQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

CAUTION. Disconnect Power

PTAC CONTROL BOARD KIT RSKP0006 INSTALLATION INSTRUCTIONS

Copeland Screw TM Compressors

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

NILFISK BA 500 Service Manual

Installation Instructions

HARNESS KIT F INSTALLATION INSTRUCTIONS. Vehicle: Mazda RX-8 Parts number F CFZ (ipod integration module) C9F4 V6 029 (Harness Kit F)

PHOENIX MINI-GUARDIAN

Section 10 Chapter 17

Installation Instructions for TJ Jeep s Fiberglass Replacement Bodies and Parts

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

FULL DC INVERTER SYSTEMS INDIVIDUAL AND MODULAR CONSTRUCTION FLEXIBLE COMBINATIONS AIR CONDITIONING COMMERCIAL AIR CONDITIONERS SDV4 2014

This air conditioner uses new refrigerant HFC (R410A).

Jeep Wrangler 4.0 Liter TJ Jeep Wrangler 2.5 Liter TJ Installation instructions

19,1 261,0 kw COOLING 23,7 333,0 kw HEATING

Product Catalog. Variable Refrigerant Flow (VRF) VRF-PRC026A-EN. Mid-Static Concealed (Ducted) Indoor Units. November 2015

Johnson Controls Rooftop Units

After installing the HEPA filters the discharge air should be monitored to ensure proper filtering efficiency. HEPA Filters

Standard Service / Installation / Operation Manual Type W & P Water / Glycol Heat Transfer Coils

QUICK FUEL TECHNOLOGY HOT ROD SERIES CARBURETORS SLAYER SERIES CARBURETORS SUPER STREET SERIES CARBURETORS

P5RF Series Rev "A" Single Packaged Air Conditioner Single Phase

2 1.Nominal Voltage 1.2V. 2 6.End Voltage of Discharge 1.0V

Installation Instructions

MEMS Air Velocity Sensor D6F-W. Application Examples. Ordering Information

Installation Instructions Electric Heaters 5 20 kw

EX Series. Electric Actuators for Ball and Butterfly Valves

RCE13. Product Specifications. 13 SEER Electric / Electric Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower.

INSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone.

VS6BF Series 2-4 Ton Capacity. VS4BF Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 5 Ton Capacity

RPHP13. Product Specifications. 13 SEER Heat Pump Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower. Controls.

Heat Recovery Ventilation

ALUMINUM CAN RECYCLING MUNICIPAL WASTE WOOD WASTE PLASTICS E-SCRAP AUTOMOTIVE SHREDDING GLASS CULLET MATERIAL RECOVERY FACILITIES

High-Performance Industrial Emergency LED Lighting LHP & LHPR SERIES

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

Installation Instruction ALG Series LED Area Light Version: 3.1

13 SEER Light Commercial 3 Phase

Tenergy Corp 1292 Kifer Road Suite 807 Sunnyvale CA 94086

P3RC-12 SEER 2 Ton thru 4 Ton Units Cooling: 23,800 to 48,000 Btuh

Installation Instructions

Model No.: outdoor unit U-16GE3E5 U-20GE3E5 U-25GE3E5 U-30GE3E5 U-16GF3E5 U-20GF3E5 U-25GF3E5

Complete Whole House Air Cleaning System Photronic Base Media Air Cleaner OWNERS GUIDE

VHIA High-Static Ducted Indoor Units - 60HZ

Installation Instructions Electric Heaters 5 20 kw

TECHNICAL SPECIFICATIONS

R-22, 13 SEER 60 Hertz

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ

This chapter describes how to perform periodic inspection and maintenance to ensure the long operating life of the chamber.

EX Series. Electric Actuators for Ball and Butterfly Valves

Cummins and Fleetguard are registered trademarks of Cummins, Inc. Mann+Hummel is a registered trademark of Mann+Hummel GMBH

Installation Instructions Page 1 of 10

CPC Series. Submittal Data Form. 15- & 20-Ton Self-Contained. Packaged Air Conditioner. with R-410A

Air terminal devices

Air Purifiers Product Guide

Transcription:

VAC System Simplicity Mitsubishi Electric Cooling and Heating of 1 http://www.mitsubishipro.com/en/professional/overview-and-benefits/be... 6/27/2013 5:02 PM System Simplicity Design, Install, Maintain Design The system allows for design flexibility, from the simplest to the most complex. It also provides for ducted or ductless systems, including virtually any application (or a variety of applications) within a single building. With the wide range of products available in our combined Mr. Slim and CITY MULTI product lines, your design can connect 1 to 50 indoor units to a single outdoor unit. Many products use T-branches and headers for the ultimate in piping design flexibility. Modular systems with a variety of indoor and outdoor units can be put together for a system that is just right for your needs. Condensing Units (heat recovery, heat pump and water-sourced) offer vertical air discharge that allows units to be installed side-by-side in a single area, saving space and resources. They also offer long line lengths - up to 2,624 feet on R2 Series and 3,280 on Y-series (one way). Additionally, you don't need space for compressor farms because the mechanical chases take up very little space. Indoor units meet your design and space needs - ducted or ductless, ceiling, floor, wall or vertical. Install Installation includes simple two-pipe systems with easy, non-polar, two-wire control connections. This means less labor and fewer materials as well as quicker, easier installation. Copper refrigerant piping is smaller and lighter than ductwork or Schedule 40 steel water pipes, so the modular outdoor unit's compact design also simplifies transportation. Maintain / Service Many other systems require retro-commissioning and constant maintenance to preserve their installed efficiency, but VRF technology has all the logic built in. System performance is constantly modified to maximize performance and comfort. System tests are available to check wiring, sensor and the refrigerant levels. Normal maintenance consists of changing filters and cleaning coils. Many systems allow an indoor unit to be serviced while other indoor units within the same piping system are still in operation. VRF technology also allows for lower maintenance costs than water-cooled chillers since water treatment issues are avoided.

9. Care and Cleaning ), MITSUBISHI ELECTRIC ~COOL n,-rf ~~ I I uu OiTF l..r...""4"... II ~ ~~ ~ / I ' PKFY-P NAMU-E PKFY -P NGMU-E Indicates that the filter needs cleaning. Ask authorized people to clean the filter. When resetting "FILTER" display When the [FILTER] button is pressed two times successively after cleaning the filter, the display goes off and is reset. Note: When two or more different types of indoor unit are controlled, the cleaning period differs with the type of filter. When the master unit cleaning period arrives, "FILTER" is displayed. When the filter display goes off, the cumulative time is reset. " FILTER" indicates the cleaning period when the air conditioner was used under general indoor air conditions by criteria time. Since the degree of dirtiness depends on the environmental conditions, clean the filter accordingly. The filter cleaning period cumulative time differs with the model. This indication is not available for wireless remote controller. Cleaning the filters Clean the filters using a vacuum cleaner. If you do not have a vacuum cleaner, tap the filters against a solid object to knock off dirt and dust. If the filters are especially dirty, wash them in lukewarm water. Take care to rinse off any detergent thoroughly and allow the filters to dry completely before putting them back into the unit ~ Caution: Do not dry the filters in direct sunlight or by using a heat source, such as an electric heater: this may warp them. Do not wash the filters in hot water (above 122 of), as this may warp them. Make sure that the air filters are always installed. Operating the unit without air filters can cause malfunction. Before you start cleaning, stop operation and turn OFF the power supply. Indoor units are equipped with filters to remove the dust of sucked-in air. Clean the filters using the methods shown in the followinqi sketches. Filter removal ~ Caution: In removing the filter, precautions must be taken to protect your eyes from dust. Also, if you have to climb up on a stool to do the job, be careful not to fall. When the filter is removed, do not touch the metallic parts inside the indoor unit, otherwise injury may result. PLFY-P NAMU-E, PLFY-P NCMU-E (j) Pull both the bottom corners of the intake grille to open the grille, then lift the filter. PKFY-P NFMU-E (j) Hold the filler lug (located at the bottom of the intake grille) and pull it out downward. @Filter @Lug To reinstall the filters, push the filter lug upward. PCFY-P NGMU-E (j) Open the intake grille. Hold the knob on the filter then pull the filter up in the direction of an arrow. To replace the filter after cleaning, be sure to insert the filter far enough until it fits into the stopper. @Filter @ Intake Grille Knob @Stopper PMFY-P NBMU-E (j) Pull the knob on the intake grille in the direction indicated by the arrow and it should open. Open the intake grille. Release the knob on the center edge of the intake grille and pull the filter forward to remove the filter. <N Knob Grille Intake orille Filter (j) Pressing the PUSH button on the outer side of the intake grille causes the intake grille to open. A filter with an intake grille on it can be removed by pulling the filter forward.