Instruction Manual. Digital Panel Meter Model 3126 CAUTION. Code Type of T/C Measuring Range Display Range Accuracy

Similar documents
MODEL 3567A. Digital MΩ Tester. Instruction Manual

Table of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION...

FX2N-2LC SPECIAL FUNCTION BLOCK

Item ref: UK & UK MTB01 & MTB02 DIGITAL MULTITESTERS. User Manual

Digital/Analog Megohmmeter Model 1026

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

1/16 DIN Temperature Controller E5CS

User Guide. Model Insulation Tester / Megohmmeter

Volt/mA Calibrator. Manual

Transmitter CSA-591 Instruction Manual

Digital/Analog Megohmmeter Model 1026 USER MANUAL

RS MODEL 2030

SERVICE MANUAL. STARTER Portable Meter ST300 ST300C ST300D ST400D. Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ (973)

SERVICE MANUAL STARTER 2100 Bench ph Meter STARTER 3100 Bench ph Meter STARTER 3100C Bench ph Meter

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

Safety design conforming to the following provisions

Portable Instruments. Bulletin 2000-E

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator

3. Input KJ: Thermocouple P: Platinum resistance thermometer G: Thermistor T: Thermocouple/platinum resistance thermometer (universal-input)

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

Models SPG5A and SPG6A

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

INSTRUCTION MANUAL IDM97II DIGITAL MULTIMETER EN FR IT DE

INSULATION RESISTANCE TESTER FOR PHOTOVOLTAIC SYSTEMS MSEI-200C INSTRUCTION MANUAL

MS52XX SMD Pressure Sensor

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

User Guide. Model Insulation Tester / Megohmmeter

UNIVERSAL CALIBRATOR M

OPERATING INSTRUCTION

INTERNATIONAL METAL ENGINEERING

Low Pressure Sensor. Overview. Specifications. Installation and Operation

THT-500-A/R INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER

INSTRUCTION MANUAL IDM67 DIGITAL MULTIMETER

7526A Precision Process Calibrator. Calibrate temperature, pressure, and low dc voltage process tools in a single benchtop instrument

TABLE OF CONTENTS 1. FEATURES SPECIFICATIONS... 1

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

AC CURRENT ANALOG CLAMP-ON TESTER MODEL MCL-350 INSTRUCTION MANUAL

AS4V DC ALARM BEFORE USE... CAUTION WARNING INSTRUCTION MANUAL AS4V MODEL. (dual or quad alarm trip; field-configurable)

Budget Series Digital Thermometer. Instruction manual Models 874F/C, 875F/C, 878 and 879

INSTRUCTION MANUAL BIPOLAR POWER SUPPLY PBA SERIES OPTIONAL RACK-MOUNTING ATTACHMENT OM-21E PRINTED IN JAPAN B

BENCHTOP INSTRUMENT BENCH TYPE DIGITAL MULTIMETER DM-1140B OPERATION MANUAL V2.0

TES-1601 INSTRUCTION MANUAL AUTORANGING INSULATION TESTER SAFETY INFORMATION TES ELECTRICAL ELECTRONIC CORP. Warnings and Safety symbols:

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

Construction diagram Semiconductor transducer Silicone oil. Stainless steel SUS316 pressure port Hastelloy C diaphragm.

MODEL ITMA - INTELLIGENT THERMOCOUPLE MODULE WITH ANALOG OUTPUT

XK3190- A7. Weighing indicator USER MANUAL

TBX-1328 High-Accuracy Isothermal Terminal Block

TOWA SEIDEN INDUSTRIAL CO., LTD.

For commissioning, maintenance and function checks of solar thermal systems Part no

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Time Electronics DC Voltage Calibrator. Technical Manual

EPS/ELA-Series User Manual EPS/ELA 250W

9142-B-P-156/AF. User s Guide. Field Metrology Well. Distribution is limited to DoD and U.S. DoD contractors only.

User Guide. Model Insulation Tester / Megohmmeter. Introduction

DP-304/DP-304-L Stepper Drive

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

Analog Resistive Touchscreen QST Series Product Specifications

DIGITAL MICROHMMETER TYPE DO7

General Specifications

Pressure Transmitters

MPM160 Pressure Sensor

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Safety design conforming to the following provisions

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

SSP-Series Portable Balances Operation Manual

Analog Output Terminal

DPS280 / DVS280 Series

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Screw-in resistance thermometers with plug connector

COMPACT SIZE HIGH PRECISION POWER ON-DELAY TIMERS. 10 position

OPERATING INSTRUCTION

BENCHTOP INSTRUMENT. Single Channel DC Power Supply SL Series Operation Manual V1.0

GS-AQ1000 VOC Indoor Air Quality Sensors

EVS RP6020. Instruction Manual

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE PTC-10 PELTIER TEMPERATURE CONTROL SYSTEM

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2

A.W. SPERRY INSTRUMENTS INC.

EGT-100 Operations and Installation Manual

Analog input module. Brief description. Page 1/8. Data Sheet

TABLE OF CONTENTS. 8.3 Online Sensor Specifications. Series TS (Models TS1, TSP, TSH, TSL,TSF, TSB1, TSB2) According to Electromatic factory procedure

Clamp Earth Tester MET-2. Instruction Manual

Communications. Auxiliary. Functions. output. functions. Transistor. Heating or cooling control is selectable (See note 2.

Dawson DAN100. Analog Multimeter User s Manual

Illustrations. Contents. Burns Connection Head. Models #22, #23 & #24 with Battery Powered LCD Indicator Instruction Manual

1. SAFETY TERMS AND SYMBOLS. Contents. 1. Safety terms and symbols Installation Operation.. 4

No. P-KAB-001 DATE PRODUCTS DATA SHEET MICRO FUSE. Type KAB. UL/cUL approved File No.E17021 RoHS COMPLIANT LEAD FREE

SAFETY PRECAUTIONS (Always read these precautions prior to use.)

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

MS52XX SMD Pressure Sensor

PG-30 PRESSURE GAUGES P G R - N FEATURES MODEL NUMBER DESIGNATION

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

OPERATING INSTRUCTION

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

Time Electronics DC Multifunction Voltage/Current/Resistance Calibrator. Technical Manual

ZIRCONIA OXYGEN ANALYZER CONVERTER

Model Insulation Tester / Megohmmeter. User Manual

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

Transcription:

Instruction Manual Digital Panel Meter Model 3126 I-01861 1. Preface Thank you for purchasing our digital panel meter 3126 series. Before use, read this manual carefully and thoroughly, and keep this manual available for routine reference. Please check contents of the package you received as outlined below. (1) Digital panel meter itself and it s connector (2) This manual Then, check for damage during transportation, and for model number and specifications. If you have noticed any damage or wrong products, contact us or our distributor. CAUTION There is no power on-off switch on the model 3126. It immediately starts to operate after turning the power. The rated data is, however, defines with more than 15 minutes warming-up times. When the product is installed in the cabinet, perform the appropriate heat radiation to keep less than 50 in it. Do not install the product in the following conditions. - Where it is exposed to direct sunlight, dust, corrosive gages, rain, etc. - Where ambient temperature or humidity is high. - Where it is exposed to excessive noise or static electricity. - Where there is constant vibration or shock. 2. Standard Specifications Model Numbering 3126 - - - 1 2 3 1 Input signal [ Thermocouple ] Code Type of T/C Measuring Range Display Range Accuracy 3126-01 R 100 ~ 1700 o C -50 ~ 1750 o C ±(0.5% of rdg + 1 o C) 3126-02 K 0 ~ 1300 o C -100 ~ 1350 o C ±(0.5% of rdg + 1 o C) 3126-04 J 0 ~ 1200 o C -50 ~ 1250 o C ±(0.5% of rdg + 1 o C) 3126-05 T -100 ~ 400 o C -150 ~ 420 o C ±(0.5% of rdg + 1 o C) Accuracy: Defined at 23 o C±5 o C, 45 to 75%RH. Temperature coefficient: ±300ppm/ o C within the 0 to 50 o C temperature range. Calibrated by standard thermal power mv input in compliance with JIS C 1602-1995. Standard contact compensation: Defined at ±2 o C within the 0 to 50 o C temperature range [ Resistance thermometer ] Code Type of sensor Measuring Range Display Range Accuracy 3126-11 Pt100Ω -199 ~ 600 o C -199 ~ 650 o C ±(0.4% of rdg + 1 o C) 3126-12 Pt100Ω -199.9 ~ 199.9 o C -199.9 ~ 199.9 o C ±(0.2% of rdg + 0.3 o C) Accuracy: Defined at 23 o C±5 o C, 45 to 75%RH. Temperature coefficient: ±200ppm/ o C within the 0 to 50 o C temperature range. Calibrated by resistance of standard resistive elements in compliance with JIS C 1604-1997. 2 Display Color Code Description Blank Red LED G Green LED 3 Option Code Blank A01 Description N/A Analog output TSURUGA ELECTRIC CORPORATION 1

General Specifications Display : Red or green LED (character height 10mm) with zero-suppress function. Over-range indication : When exceeding the display range, blinks with min. value or max. value. Open circuit of input : Thermocouple (blinking with min. value) Resistance thermometer (blinking with max. value) Resolution : 1 o C for thermocouple, 1 o C or 0.1 o C for resistance thermometer. External resistance : Max. 500Ω for thermocouple, Max. 5Ω /lead wire for resistance thermometer. Overload : DC±3.3V Sampling Rate : Approx. 2.5 times/sec. Input Type : Single ended, floating input. A/D Conversion : Δ-Σ conversion system. Noise Rejection : Normal mode (NMR) 50dB or more. Hold function : Measured data and analog output (option) are held. Not isolated from the input. Average calculation : 4 sampling display datum can average (fixed). Withstanding Voltage : Input terminals - Case : AC500V each for 1 min. terminals - Case : AC500V each for 1 min. terminals - Input terminals : AC500V each for 1min. Insulation Resistance : DC500V 100MΩ or more. : DC12~24V allowance : DC9~32V Power Consumption : Approx. 60mA at 12VDC. Approx. 40mA at 24VDC. Operating Temperature : 0~50 o C Storage Temperature : -20~70 o C Weight : Approx. 55g Mounting Method : Snap-in type from the panel front. Optional function Analog output : Not isolated with the input. Voltage: 10mV/ o C (for 0.1 o C resolution) 1mV/ o C (for 1 o C resolution) Accuracy: 0.2%FS (for display) Load: 20kΩ or more. (resistive) Temperature coefficient: ±200ppm/ o C(±400ppm/ o C for J and T sensors) Response time: 1.2s or less. Dimensions Thermocouple 48 5 50 19.5 1 24 44 10 1 4 5 6 7 8 9 10 21.5 Resistance thermometer 5 50 17 1 2 3 4 5 6 7 8 9 10 2 TSURUGA ELECTRIC CORPORATION

Mounting Remove the connector at the rear side of the case, then insert from the panel front. Panel cut dimension is 45 +0.5 0 22.2 +0.3 0 mm. Panel thickness should be 1 to 5 mm. Connector arrangement Thermocouple input +INPUT - HOLD NC NC COM HOLD NC 1 2 3 4 5 6 7 SHIELD NC 8 - + 9 10 Resistance thermometer input INPUT HOLD A B B NC COM HOLD NC NC 1 2 3 4 5 6 7 8 - + 9 10 SHIELD TSURUGA ELECTRIC CORPORATION 3

Input Thermocouple input Tighten each thermocouple with correct polarity. Use a slotted driver with 2.5(w) 0.5(t)mm. Resistance thermometer input Connect 3-wire Pt100Ω Note) Input and power line shall lay separately. Otherwise, display may be unstable. Hold (HOLD) Display and analog output can be held by connecting the HOLD terminal and the COM terminal. Active L, I IL -1mA, L =0~0.8V, H =3.5~5V Common (COM) For HOLD terminal. NC NC is not connected. Do not use for junction purpose. (+,-) Use within the range from DC 9 to 32V. CAUTION Hold and com terminal is not isolated to the input. Use a photo-coupler or switch to insulate. It is essential when using the input floating. When using plural numbers of the product, the hold terminal should be insulated at each instrument. CAUTION Do not apply over voltage nor AC power to avoid damage. Analog output - Analog output is terminal 7 and 8. - Outputs in proportional to the input signal to A. OUT+ and A OUT-. - With the adjustment volume. - Not isolated with the measuring input, HOLD nor COM. - Connect with the correct polarity. - Not available moving average. - Use a small phillips head driver for adjustment. Timing Chart ZERO SPAN Analog output 4 5 6 7 8 A.OUT+ A.OUT- 400ms SAMPLING S1 S2 S3 S4 DISPLAY D0 D2 D3 ANALOG OUT (Option) HOLD A0 t A2 A3 t: Approx. 400ms when using thermocouple. Approx. 600ms when using resistance thermometer. Parameter Setting Internal layout from the front panel Mode Switch M DP3 DP2 DP1 DP0 L R Shift Switch > > Up Switch Function of each switch Mode Switch M : Switches to setting mode from the measuring mode and memories. Shift Switch > : Shifts setting value during the parameter setting. Up Switch : Changes setting value and items. Indications Lit up Blinking Turned off 4 TSURUGA ELECTRIC CORPORATION

- Average calculation Disable or enable the average calculation. Measurement mode Set the M switch to the left (L side). Return the M switch to the middle to store the setting value in memory. Model 3126 Press switch to display the moving average setting condition. Press switch to change setting. Press switch to select the moving average function (Note) Setting mode Note: Enable Disable Up switch : Enable Disable Enable (in order) Blinking Press > switch and the display changes to. Calibration In order to maintain long term accuracy, periodical calibration at an interval of about one year is recommended. Make a calibration in the ambient condition of 23 o C±5 o C, 75%RH or less. Thermocouple Prepare a voltage regulator, cold contact circuit (thermos bottle with ice water), and standard thermocouple. Shift the M switch to the right. Keep pushing the switch, and turn the power on. starts. Wire as shown in the Fig. 1. Shift the M switch to the right. Turn the power on with pushing the switch. Keep pushing at least 5 seconds Display the sensor number. Refer to the Table 1. Shift the ZERO calibration by pushing the > switch. DP0 and DP1 are lit. Display resolution is 0.1 Apply 0V. Set ZERO value by pushing the switch. Shift the MAX calibration by pushing the > switch. DP2 and DP3 are lit. Display resolution is 1 Apply Max value as shown in Table 1. Set MAX value by pushing the switch Shift the GAIN calibration of the cold contact circuit by pushing the > switch. DP1 is lit. Apply 500.0mV. Set GAIN value by pushing the switch. Re-wire as shown in Fig. 2. Shift the ZERO calibration of the cold contact circuit by pushing the > switch. DP1 and DP2 are lit. Apply 0.0mV. Set 0 by pushing the switch. Shift the M switch to the center. End calibration by turning the power off. New calibration is effective after restarting. Do not turn off the power during calibration to memorize new valve. During calibration, it operates with a moving average. When calibrating at excessive range, back to the input value display after blinking the Error message ( Err). Calibrate within the range. No. Name Max. value CAL0 K sensor 1300 o C 52.410mV CAL1 J sensor 1200 o C 69.553mV CAL2 R sensor 1700 o C 20.222mV CAL4 T sensor 400 o C 20.872mV Fig.1 Table 1 + - - + 1 2 3 4 8 9 10 Cold junction circuit cu cu Referential + - thermocouple + Standard - voltage generator + - - + 1 2 3 4 8 9 10 Ice water 0 cu+ Standard cu- voltage generator Fig.2 TSURUGA ELECTRIC CORPORATION 5

Resistance thermometer Connect the variable resistor as shown in Fig 3. Calibrate at 0.0 and 600.0 for both model code-11 and -12. Shift the M switch to the right. Turn the power on with pushing the switch. starts. Shift the M switch to the right. Turn the power on with pushing the switch. Keep pushing at least 5 seconds. Display the sensor number A. Number A is for the model code -11, and B for -12. Shift the ZERO calibration by pushing the > switch. DP0 and DP1 are lit. Apply 100.00Ω(0.0 ). Set ZERO value by pushing the switch. Shift the MAX calibration by pushing the > switch. DP2 and DP3 are lit. Apply 313.71Ω(600.00 ). Set MAX value by pushing the switch. NOTE: It is normal even though the display does not show 6.0.0 0. Shift the M switch to the center. End calibration by turning the power off. New calibration is effective after restarting. Do not turn off the power during calibration to memorize new valve. During calibration, it operates with a moving average. When calibrating at excessive range, back to the input value display after blinking the Error message ( Err). Calibrate within the range. Standard variable resistor A B B 1 2 3 4 8 9 10 Fig.3 - + Maintenance Store the instrument within the rated storage temperature (-20~70 o C). When the front panel or the case is cleaned, use soft cloth dipped with cleaner liquid. Do not use organic solvent like benzene or paint thinner as they may deform or discolor the case. Contact Information Name : Tsuruga Electric Corporation Address : 1-3-23 Minami-Sumiyoshi, Sumiyoshi-ku, Osaka-shi 558-0041 Japan 6 TSURUGA ELECTRIC CORPORATION