INW Panel Meter Reading an INW PT12 Sensor

Similar documents
WJ-Series. Turbine Meter Instructions ISO. 6 Meter. 3 Meter. Precision Flow Measurement. An ONICON Brand 9001:2008. if ie

MJ/MJH-Series. Pulse Meter Instructions ISO. Precision Flow Measurement. An ONICON Brand 9001:2008. if ie

WMP-Series. Plastic-Bodied Magmeter Instructions ISO. 2 inch. Precision Flow Measurement. An ONICON Brand 9001:2008 PROUDLY MADE IN THE USA.

PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.

MANUAL Model: PT 12/24-60 Solar Converters Inc. - Rev. F

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

HP190SL Series Slimline Radon Fans

FADE Series Wall Axial Fans

4-SIDED HOCKEY SCOREBOARD LED BAR DIGIT INSTRUCTION MANUAL REVISION DATE: PART#:

EMISSION CONTROL WARRANTY STATEMENT

Thermaltake Warranty / Support Information

Charging with AC (wall) Charger

ST-70 CONTROL OPERATING MANUAL REVISION DATE: PART#:

4-SIDED BASKETBALL SCOREBOARD LED BAR DIGIT INSTRUCTION MANUAL REVISION DATE: PART#:

CBC-160-1N and CBC-160-2N Clutch/Brake Controls

Users Guide for Ac-sync

Installation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator

LED LARGE WALL PACK (CUTOFF & STANDARD)

ADJUSTABLE COMFORT ASSEMBLY INSTRUCTIONS

Spy pocket Jeepmeter ope rati ng instructions

Toro Sprayer Calibration Tool

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

MaxLite LED UTILITY WRAP FIXTURES

Installation and Operation Manual

Cardinal DETECTO. PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual

Analog Durometer Model AD-100

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual

Electromagnetic Particle Clutches and Brakes Models: POC, PHC-R, PMC-A3, POB, PRB and PTB-BL3 P Performance Manual

SYSTEM MANUAL. Automated Motorized Hydraulic Traffic Controller. Revision CS72-HTC

User Manual. Posture+ Adjustable Base. For customer service call:

INDOOR LED BAR DIGIT HOCKEY SCOREBOARD INSTRUCTION MANUAL REVISION DATE: PART#:

SUNTURA SOLAR TRACKER

Illustrations on the manual are for installation purposes only. It may not be identical to the fixture purchased.

Installation & Operation Manual. Electrak 1 Series / Electromechanical Linear Actuators Limit Switch, & Potentiometer Feedback, and Long Life Models

DUAL WIDEBAND AIR/FUEL RATIO GAUGE Product Numbers: GS-W702W_Dual, GS-C702W_Dual, GS-T702W_Dual

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

FREQUENTLY ASKED QUESTION SERIES. BANJO BOLTS WHY THE BAD RAP? 6.0L Powerstroke Diesel. Last Updated: 7/2/2018 Page 1 of 3 S Diesel, LLC

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

Preassembled Clutch/Electrically Released Brake Module

SUNTURA HD SOLAR TRACKER

(L 70 ) 3000K / 4000K / 5000K 12 50,000 50, K / 4000K / 5000K 15 50, K / 4000K / 5000K 18 50,000

OWNER'S MANUAL L A W N R O L L E R PRT-481S BH. Safety Assembly Operation Repair Parts Maintenance. Visit us on the web!

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

Installation Precautions. Use Precautions. Specifications

OWNERS MANUAL JANUARY 2007 ISO

FADE SERIES. Typical Specifications for Model FADE Sidewall Propeller Fans Sidewall propeller fans shall be of the direct driven type.

TECHNICAL INFORMATION

Warner Electric UNIBRAKE Motor Brakes

12 Volt Utility Controller for 4, 6 or 8 Brakes No P

GLYCOL SYSTEM MONITOR (GSM)

6.0 SPECIFICATIONS CONTENTS. Calibration. According to factory procedureeeeeeeeeeeeeee Accuracy*

TBX10A INSTALLATION/OWNER'S MANUAL 10" Sealed Enclosure with Built-in Amplifier

END USER TERMS OF USE

Installation Instructions Receiver Rack (Part # 7700) Universal Application

Smith & Hawken Propane Tank Cover dpci # stock # ZAZ15200T

Installation & Operators Manual

DISCOVER ADVANCED ENERGY SYSTEM - AES WARRANTY POLICY

HR-20P Pneumatically Controlled Pressure Regulator

AD-7 THERMAL INDICATING AMMETER

Waukee AutoLube User Manual

PVI 60KW, PVI 82KW, PVI 95KW

DC Distribution Panel User Guide # S

Flo-Way. Measure Granular or Powdered Material. Stand Alone or Connect to Other Devices for Blending. Used by Successful Producers World-Wide

II DISTRIBUTION & SUBSTATION TYPE C

Installation Power Management Unit Battery Cables and Battery Harness

Reference Manual FM-200 Series

TABLE OF CONTENTS. 8.3 Online Sensor Specifications. Series TS (Models TS1, TSP, TSH, TSL,TSF, TSB1, TSB2) According to Electromatic factory procedure

Model:M5B/M5W/M5N. Installation Guide. Specifications Desktop Weight Capacity Keyboard Tray Weight Capacity Height Adjustable Range

Installation Instructions

INSTALLATION & OPERATING INSTRUCTIONS: REVOLUTION SPINEBOARD ATTACHMENT WARNING

BroadBand PowerShield. 20 AHr Battery. User Manual

6 OFF ROAD LIGHT BAR

INSTALLATION & OWNER'S MANUAL

DWS404 DWS524 DWS654 DWS684 DWS694. DWS SERIES INSTALLATION/OWNER'S MANUAL Car Audio Speakers

USER GUIDE EMERGENCY JUMP STARTER PORTABLE POWER SUPPLY INTELLIBOOST ULTRA RG600 12V 600A REV 1.16B

3 Station Bike Rack Organization Center

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

User Guide IGD Series

TS69 TS65 TS55 TS45 TS5768 TS SERIES INSTALLATION/OWNER'S MANUAL

BAK1500 INSTALLATION/OWNER'S MANUAL Compact Amplified Subwoofer

Utility Controller Hand Air Operated

60 PSI Boost Gauge. For Product Numbers: MT-DV01_60, MT-WDV01_60

Electromagnetic Particle Brakes Model: PRB-H

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev

Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB

Submersible Waterfall Pump 1200 Gallons Per Hour

Raydot LLC 24 Actuator (115 VOLT)

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

Product Parts Information

MaxLite LED Enclosed & Sealed Jelly Jars

Female Plug. connecting to Fuel Quantity

Operator s Safety and Service Manual

Installation Instructions

OWNERS MANUAL JANUARY 2007 ISO

Woolich Racing. Bike Harness Installation Instructions Suzuki Harness Type 4a GSX1300R (Hayabusa)

ADI-125/750 ADI-125/1500 ADI-125/2500

WiFi Tank Level Monitor Installation Instructions

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

TOTALIZER-TRANSMITTER

Transcription:

INW Panel Meter Reading an INW PT12 Sensor PROUDLY MADE IN THE USA ISO 9001:2008 Certified Company

Table of Contents Introduction...5 What is an INW Panel Meter for an INW PT12 Smart Sensor?...5 Initial Inspection and Handling...5 Do s and Don ts...5 Setup...6 Connecting the Meter...6 Operation...8 Meter Settings...8 Appendix A - Display Units... 11 Appendix B - Meter Reset... 13 Complete Meter Configuration... 14 Seametrics Limited Warranty... 17 1997-2016 Seametrics. All rights reserved. INW is a Division of Seametrics. Registered trademarks and trademarks belong to their respective owners. Seametrics 253.872.0284 Page 3 inwusa.com

Seametrics 253.872.0284 Page 4 inwusa.com

Introduction What is an INW Panel Meter for an INW PT12 Smart Sensor? This is a Modbus meter that is specially configured to read an INW PT12 Pressure/ Temperature Smart Sensor. By default, the meter displays pressure in PSI. The meter can also be set to display pressure in feet of water or meters of water or to display temperature in degrees Celsius. The meter is available in either an 85-265 VAC version for wired-in power or in a 12 VDC version for remote or portable usage. The meter comes installed in a weatherproof Nema 4X enclosure with the PT12 Smart Sensor connected through a wire seal. An INW PT12 Smart Sensor is a submersible pressure/temperature sensor which can communicate via Modbus, as well as SDI-12. When used with this meter, the sensor communicates via Modbus. Initial Inspection and Handling Upon receipt of your meter, inspect the shipping package for damage. If any damage is apparent, note the signs of damage on the appropriate shipping form. After opening the carton, look for concealed damage. If concealed damage is found, immediately file a claim with the carrier. Do s and Don ts Do handle the device with care. Don t install the device so that the box or connector is submerged. Don t bang or drop the device on hard objects. Seametrics 253.872.0284 Page 5 inwusa.com

Setup Connecting the Meter Connecting the Meter Sensor Connection The sensor is wired to the meter as shown in Figure 2. The meter supplies 12 VDC power to the sensor through a dropping resistor and voltage regulating zener diode. Direct wiring sensor Seametrics 253.872.0284 Page 6 inwusa.com

Power Connection INW does not supply a power connection. It is up to the client and their engineers to wire the power connection. Meter manufacturer power specifications: AC: 85-265 VAC, 50/60 Hz, 15 Watts Recommended fuse: 1 A, 250V, slow-blow Wire: Copper with 60 C or 60/75 C insulation Caution! Bulkhead and Sensor Wiring Observe all safety precautions. To ensure safety and prevent damage to the meter, wiring should be done by a qualified technician in accordance with all local, state, and federal guidelines. Bulkhead Wiring Sensor Wiring Baud Rate The panel meter is set to communicate at 19,200 baud. The normal baud rate for the PT12 is also 19,200. The PT12 can communicate at 38,400, 19,200, or 9600 baud. The panel meter can communicate at either 19,200 or 9600 baud, but not at 38,400. If your PT12 has been set to a different baud rate, contact INW for information on how to reset the baud rate. Seametrics 253.872.0284 Page 7 inwusa.com

Operation Your meter comes preconfigured to read your INW PT12 Pressure/Temperature sensor. Once the meter is powered and the sensor is connected, the meter should immediately begin displaying pressure readings. Meter Settings Though your meter comes preconfigured, there may be times when you want to change some of the settings. The meter is controlled via four buttons on the front of the meter face: Figure 3: Meter control buttons The most common settings are detailed below. For complete settings, see the Appendix. Slave ID MENU RESET MAX ACK The Slave ID is the sensor address assigned to your sensor. You can find this address on the calibration sheet that came with your sensor. If you need to reset the address in the meter, do so as follows: To change a value on the meter, use the to select the digit you want to change. Use the to cycle through acceptable values. Seametrics 253.872.0284 Page 8 inwusa.com

Register Number The meter reads a particular register (memory) address on the sensor in order to display a reading. The PT12 has three registers - one for pressure, one for temperature, and one for voltage. The meter comes preconfigured to read pressure. If you want to read temperature, you must set the meter to read the correct register, as shown below. (Note, if you are using other than PSI as display units for pressure, see the following section on display units.) NOTE: With firmware version 0.13 and higher you can also read from registers: 462593 for pressure 462595 for temperature 462597 for voltage Display Units The panel meter comes preconfigured to display readings in the units you have ordered for your PT12. The PT12 default is PSI for pressure and degrees Celsius for temperature, unless something else is specified in your order. If you need to change units, see Appendix A. Seametrics 253.872.0284 Page 9 inwusa.com

Polling Interval The polling interval controls how often the meter queries the sensor for a new value. The meter comes preconfigured with a two second polling interval. You can change this interval as follows: Decimal Point Placement The meter can display a maximum of six digits and comes preconfigured to display three digits followed by three decimal places. For example, 154.925. You can change the number of decimal places as follows: Seametrics 253.872.0284 Page 10 inwusa.com

Appendix A - Display Units If your PT12 displays pressure readings in PSI and you want to display in feet of water or meters of water, you can change the readout on the meter as shown below. If your PT12 is configured for something other than PSI and you want different units than what is displaying, contact INW for information on changing the units on the PT12. Units Input 1 Display 1 Input 2 Display 2 PSI -10.000-10.000 299.999 299.999 Feet H2O -10.000-23.070 299.999 692.098 Meters H2O -10,000-7.031 299.999 210.926 Set these in the meter as follows: Seametrics 253.872.0284 Page 11 inwusa.com

Temperature You cannot change display units for temperature. They will always display in degrees Celsius. However, if you are using other than PSI for pressure and you later want to read temperature, you must set the display units per the chart below. Failure to do this will result in erroneous temperature readings. If you switch back to pressure, you must reset for pressure units again. Units Input 1 Display 1 Input 2 Display 2 Temperature -10.000-10.000 100.000 100.000 Default - if only using PSI If you have been using other than PSI for pressure units and wish to return to using just PSI, then change the display units as shown in this chart. Units Input 1 Display 1 Input 2 Display 2 Default -199.999-199.999 999.999 999.999 Once these defaults have been reset, you can switch between reading pressure and reading temperature without having to change the display settings. Seametrics 253.872.0284 Page 12 inwusa.com

Appendix B - Meter Reset On occasion the meter can get into a state where you are unsure what it is doing. This can happen if a mistake is made while changing settings or if someone else has used the meter for some other purpose. It is often easier to set the meter back to factory defaults than to determine exactly what had changed. Follow the steps below to set the meter back to factory defaults: Seametrics 253.872.0284 Page 13 inwusa.com

Complete Meter Configuration The meter is controlled via four buttons on the front of the meter face. Though your meter comes preconfigured, if it should ever need to be completely reset, follow the instructions below: Complete Reset To change a value on the meter, use the to select the digit you want to change. Use the to cycle through acceptable values. NOTE: With firmware version 0.13 and higher you can also read from registers: 462593 for pressure 462595 for temperature 462597 for voltage (Continued on next page.) Seametrics 253.872.0284 Page 14 inwusa.com

(Continued from previous page.) (Continued on next page.) Seametrics 253.872.0284 Page 15 inwusa.com

(Continued from previous page.) Further Information: If you need further information on the meter capabilities or settings, you can download the meter manual from www.predig.com/download.asp?file=360 Seametrics 253.872.0284 Page 16 inwusa.com

SEAMETRICS LIMITED WARRANTY The limited warranty set forth below is given by Seametrics, with respect to Seametrics and INW brand products purchased in the United States of America. Seametrics warrants that products manufactured by Seametrics, when delivered to you in new condition in their original containers and properly installed, shall be free from defects in material and workmanship. Seametrics products are warranted against defects for a period of two (2) years from date of installation, with proof of install date. If no proof of install date can be provided, warranty period will be two (2) years from date of shipment from Seametrics, as defined on Seametrics invoice. Seametrics obligation under this warranty shall be limited to replacing or repairing the part or parts, or, at Seametrics option, the products, which prove defective in material or workmanship. The following are the terms of Seametrics limited warranty: a. Buyer must give Seametrics prompt notice of any defect or failure and satisfactory proof thereof. b. Any defective part or parts must be returned to Seametrics factory or to an authorized service center for inspection. c. Buyer will prepay all freight charges to return any products to Seametrics factory, or another repair facility. as designated by Seametrics. d. Defective products, or parts thereof, which are returned to Seametrics and proved to be defective upon inspection, will be repaired to factory specifications. e. Seametrics will deliver repaired products or replacements for defective products to the buyer (ground freight prepaid) to the destination provided in the original order. f. Products returned to Seametrics for which Seametrics provides replacement under this warranty shall become the property of Seametrics. g. This limited warranty covers all defects encountered in normal use of Seametrics products, and does not apply to the following cases: i. Loss of or damage to Seametrics product due to abuse, mishandling, or improper packaging by buyer ii. iii. iv. Failure to follow operating, maintenance, or environmental instructions prescribed in Seametrics instruction manual Products not used for their intended purpose Alterations to the product, purposeful or accidental v. Electrical current fluctuations vi. vii. viii. ix. Corrosion due to aggressive materials not approved for your specific product Mishandling, or misapplication of Seametrics products Products or parts that are typically consumed during normal operation Use of parts or supplies (other than those sold by Seametrics) which cause damage to the products, or cause abnormally frequent service calls or service problems h. A new warranty period shall not be established for repaired or replaced material, products, or supplied. Such items shall remain under warranty only for the remainder of the warranty period on the original materials, products, or supplies. i. In the event that equipment is altered or repaired by the buyer without prior written approval by Seametrics, all warranties are void. Damage caused by equipment or accessories not manufactured by Seametrics may void the product s warranty. j. SOFTWARE: The Seller grants the user a non-exclusive license to use Seametrics software, according to the following limitations and conditions: i. The user may install the software on one or more desktop or laptop computers. ii. iii. iv. All title and intellectual rights to the software are owned by Seametrics. No copies may be made or distributed except as described above. The user may not modify or reverse-engineer the software. THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, WHETHER ORAL, WRITTEN, EXPRESSED, IMPLIED OR STATUTORY. NO IMPLIED WARRANTY, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, APPLIED TO THE PRODUCTS AFTER THE APPLICABLE PERIOD OF THE EXPRESS LIMITED WARRANTY STATED ABOVE, AND NO OTHER EXPRESS WARRANTY OR GUARANTY, EXCEPT AS MENTIONED ABOVE, GIVEN BY ANY PERSON OR ENTITY WITH RESPECT TO THE PRODUCTS, SHALL BIND SEAMETRICS. SEAMETRICS SHALL NOT BE LIABLE FOR LOSS OF REVENUES, OR PROFITS, OR INCONVENIENCES, EXPENSE FOR SUBSTITUTE EQUIPMENT OR SERVICE, STORAGE CHARGES, LOSS OF DATA, OR ANY OTHER SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGE CAUSED BY THE USE OR MISUSE OF, OR INABILITY TO USE THE PRODUCTS, REGARDLESS OF THE LEGAL THEORY ON WHICH THE CLAIM IS BASED, AND EVEN IF SEAMETRICS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN NO EVENT SHALL RECOVERY OF ANY KIND AGAINST SEAMETRICS BE GREATER IN AMOUNT THAN THE PURCHASE PRICE OF THE PRODUCT SOLD BY SEAMETRICS AND CAUSING THE ALLEGED DAMAGE. WITHOUT LIMITING THE FOREGOING, YOU ASSUME ALL RISK OF LIABILITY FOR LOSS, DAMAGE, OR INJURY TO YOU AND YOUR PROPERTY AND TO OTHERS AND THEIR PROPERTY ARISING OUT OF USE OR MISUSE OF, OR INABILITY TO USE THE PRODUCTS NOT CAUSED DIRECTLY BY THE NEGLIGENCE OF SEAMETRICS. SOME STATES DO NOT ALLOW LIMITATIONS ON THE DURATION OF AN IMPLIED WARRANTY, SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU. SIMILARLY, SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATIONS OF CONSEQUENTIAL DAMAGE, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS; HOWEVER, YOU MAY ALSO HAVE OTHER RIGHTS WHICH MAY VARY FROM STATE TO STATE. Seametrics 253.872.0284 Page 17 inwusa.com

Seametrics 253.872.0284 Page 18 inwusa.com

Seametrics 19026 72nd Avenue South Kent, Washington 98032 USA (P) 253.872.0284 (F) 253.872.0285 1.800.975.8153 inwusa.com LT-14414r5.0-20161206 12/6/16