CEMLINE CORPORATION P. O. BOX 55 CHESWICK, PENNSYLVANIA Phone: (724) FAX (724)

Similar documents
CEMLINE CORPORATION P. O. BOX 55 CHESWICK, PENNSYLVANIA Phone: (724) FAX (724)

CEMLINE CORPORATION P. O. BOX 55 CHESWICK, PENNSYLVANIA Phone: (724) FAX (724)

Installation, Operation, and Maintenance Manual CEMLINE CORPORATION

Installation, Operation, and Maintenance Manual CEMLINE CORPORATION

Installation and Maintenance Manual CEMLINE CORPORATION

Installation and Maintenance Manual CEMLINE CORPORATION

EC4 SERIES CRYOGENIC VALVES 1/4 2 Sizes

2001 SERIES CRYOGENIC BAR STOCK BODY VALVES

SV HIGH VACUUM (Positive Relief) SEAL-OFF VALVE 1 Inch Size

SAX Electronic Valve Actuator

MVF461H Series Modulating Control Valves with Magnetic Actuators, Positioning Control and Position Feedback for Hot Water and Steam

OnCommand Troubleshooting Guide Hayward Industries

Technical Instructions Flowrite 599 Series SKD6xU Electronic Valve Actuators 24 Vac Proportional Control Description Features Application

SAX Electronic Valve Actuator

ANALOGUE INSULATION-CONTINUITY and VOLTAGE METER

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

SKD62UA Series Electronic Valve Actuator, Advanced Features

Submerged Heating Coil

3-PHASE SMART CONTROLLER STP-SCIIIC INSTALLATION GUIDE

Declaration of Conformity

JST Series. Cemline STONESTEEL Jacketed Storage Tanks

Instruction Manual. Model 307A Analog Insulation & Continuity Meter

SMALL FLOW AIRMATE PRESSURE REDUCING VALVES AND AIR LOADERS CLASSES A-2, AG-2, AF-2, AFG-2, ETC.

Flowrite EA 599 Series SKD Electronic Valve Actuator 24 Vac Proportional Control

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator.

Third Generation NITE Phoenix

CRECOMZR054B00 CRECOMZR055B00. VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS WARNING TABLE OF CONTENTS

3 Phase Smart Controller

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

Extended Battery Cabinet for Nfinity

Model H30 Operation Manual

Modulating control valves with magnetic actuators, PN 16

MXF461 U Series Modulating Control Valves with Magnetic Actuators

Power Controller. (see note 1) 10 sec

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

Tracer VMA with AutoReg

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

COOPER POWER SERIES. Electronic control battery testing, charging, and replacement instructions. Reclosers MN280074EN

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

pplication Note (Revision A) Original Instructions Replacing the ST-125 Engine Control with an L-Series Speed Controller

MT-1 Tracer Meter. RENOGY MT-1 Tracer Meter for Duo Battery Charge Controller E. Philadelphia St., Ontario CA

User Manual Digital Water Level Indicator for rain water storage tanks

1ZSE en, Rev. 4. On-load tap-changers, type UC User s manual

CP-9301 CP Application. Features. Applicable Literature. Electronic Actuator Drives General Instructions

PAGE Both power cords must be connected & powered to operate the E-TES SD 120 volt unit.

DCC-3000 Climate Control for Vintage Air GEN-IV systems

Modulating control valves with magnetic actuator PN 16

Mini Multimeter with Non-Contact Voltage Detector (NCV)

QVT MULTIVARIABLE TRANSMITTER

AC Irrigation and Propagation Controllers I Four Station, 5006-I and 5006-IP Six Station

Instruction Manual MINI IRRIGATION CONTROLLER.

Electro-hydraulic actuators for valves

MODULATING SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

TC62D Installation Instructions

Factory Packaged Controls. OE (AAON Part No. V12090) MODGAS-X Controller Field Technical Guide

Safe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual

SAVE THESE INSTRUCTIONS

Patient Lift Scale Indicator Owner s Manual

Owner's/Installation Manual

KEWTECH. KT56 digital multi function tester. Instruction manual

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

User Guide. Model Insulation Tester / Megohmmeter. Introduction

Differential Pressure Transmitter

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend

Service Manual. Extractor Model XR28QP. For The. For: Troubleshooting Adjustments

Optimal Series. Automatic Transfer Switch. Installation and User Manual for the OPT2225 Automatic Transfer Switch. Full Version

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

INSP-3 Wiring Inspection Tester

i n s t r u c t i o n m a n u a l

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions.

Electronic Proportional (EP) Control for Medium Duty Piston Pumps

A419ABG-3C Electronic Temperature Control

Overview. References TEST SPECIFICATION FORT WORTH, TEXAS TROTTER CONTROLS REPORT X TS-0005 A MODEL ORDER TITLE BY CHK D. Tests

Troubleshooting Guide

Technical Information and Diagnostic Guide RestStar Use this guide with 5700XE RestStar Unit. Western Star 5700XE.

Troubleshooting Guide

ECLIPSE Laundry Dispenser Controller

OIL FIELD ELECTRIC ACTUATOR INSTRUCTION MANUAL SPECIAL APPLICATIONS ACTUATORS Q 6.0.1

Cannondale Diagnostic Tool Manual

MXG MXF Modulating control valves PN 16 with magnetic actuators. Building Technologies HVAC Products

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

SERVICE MANUAL (DOMESTIC & INTERNATIONAL)

Generator Sets Controller 210. Operation Manual. Ver1.0

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Electronic Proportional (EP) Control for Heavy Duty Series 2 Piston Pumps Model 33

MF4E MF4E

ATLAS Wheel Balancer Electrical Flow Chart

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

RR Concepts. The StationMaster can control DC trains or DCC equipped trains set to linear mode.

INSTALLATION/OPERATING INSTRUCTIONS MCP

CM52 Network Protector with Arc Flash Reduction Module

Start-Up, Operation and Service Instructions

Wiring diagrams on page 29 are for reference only. For detailed vehicle wiring refer to Navistar documents.

Coleman Air Diversion Controller Model C40

TCM & MAT Data Logger Battery Replacement Instructions

Switching DC Power Supply

Transcription:

Installation, Operation, and Maintenance Manual CEMLINE CORPORATION Electronic Controls for Water Heaters with RWD45U Controller CEMLINE CORPORATION P. O. BOX 55 CHESWICK, PENNSYLVANIA 15024 Phone: (724) 274-5430 FAX (724) 274-5448 www.cemline.com

Table of Contents Section Page Disclaimers... 1 Contact Information... 1 General Notes and Warnings... 2 Warnings... 2 Connecting the Electric Power Source... 3 The Controller... 4 Adjustments... 4 Main Screen... 5 Setting Operating Temperature Set Point... 6 Setting Single Safety System... 7 Setting Double Solenoid Safety System... 8 Wiring Diagram for M2H and M3P Valves... 9 Wiring Diagram for MXG and MFX Valves... 10 Wiring Diagram for MVF Valves... 11 Testing the Temperature Sensor... 12 MXG and MXF Valve Information... 13 M3P and M2H Valve Information... 14 MVF Valve Information... 15 General Valve Information... 17 Magnetic Coil Resistance Information... 18 Notes... 19 2006 Cemline Corporation. All Rights Reserved. All trademarks in this manual are property of Cemline Corporation, unless otherwise noted or in any other way set forth as a third party rights. Unauthorized use of these trademarks, as well as the materials presented in this manual, is expressly prohibited and constitutes a violation of the intellectual property rights of Cemline Corporation. i

Disclaimers This Installation, Operation, and Maintenance Manual is intended to be as complete and up to date as possible. It covers the installation, operation, and maintenance procedures for CEMLINE CORPORATION s Electronic Controls. CEMLINE reserves the right to update this manual and other product information concerning installation, operation, and/or maintenance, at any time and without obligation to notify product owners of such changes. CEMLINE is not responsible for inaccuracies in specifications, procedures and/or the content of other product literature, supplied by the manufacturers of components used in CEMLINE Electronic Controls. CEMLINE strives to use only the highest quality components; however, CEMLINE has no direct control over their manufacture, or their consistent quality. CEMLINE is not responsible for injury to personnel or product damage due to the improper installation, operation, and/or maintenance of CEMLINE Electronic Controls. All installation, operation, and maintenance procedures should only be performed by trained/certified personnel. All personnel performing these procedures should completely and carefully read and understand all supplied materials before attempting the procedures. All personnel should pay strict attention to all Notes, Cautions, and Warnings that appear within the procedures detailed in this manual. CEMLINE welcomes user input as to suggestions for product or manual improvement. Contact Information For information concerning warranties, or for questions pertaining to the installation, operation or maintenance of CEMLINE products, contact: CEMLINE CORPORATION P.O. Box 55 Cheswick, PA 15024 USA Phone: (724) 274-5430 USA Fax: (724) 274-5448 www.cemline.com To order replacement parts, contact CEMLINE CORPORATION at the address listed above, or call toll free: USA/Canada/Caribbean Phone: (800) 245-6268 Note: Please include the model and serial number of the unit for which the parts are being ordered. If ordering by phone, please have this information readily available. 1

General Information Notes This manual is intended to cover installation, operation, and maintenance procedures for CEMLINE CORPORATION Electronic Controls. If questions are not answered by this manual, or if specific installation, operation, and/or maintenance procedures are not clearly understood, contact CEMLINE CORPORATION for clarification before proceeding. All installation, operation, and maintenance procedures should be performed only by - experienced, trained and certified personnel. Personnel should be trained in and familiar with correct piping and electrical procedures and methods, and should be experienced in working with hot/boiler water systems. CEMLINE CORPORATION Electronic Controls are designed for indoor use only, unless otherwise required by design specifications. If the unit is damaged during installation, oepration, or maintenance, complete the following steps: Warnings! 1. Turn off and lock out the electric power supply to the unit in an approved manner. 2. Turn off all incoming steam valves. 3. Contact in-house maintenance personnel or CEMLINE CORPORATION for instructions. As with any piece of equipment that utilizes hot/boiler water and electricity, the potential exists for severe personal injury if proper installation, operation, and maintenance procedures are not followed. Listed on the following pages are specific warnings pertaining to CEMLINE Electronic Controls. All warnings should be carefully read and understood. All precautions contained in the warnings should be carefully followed to reduce the chance of injury. Note: Throughout this manual, warnings will be denoted by the symbol. All documentation for each major component has been included with the unit. It is strongly recommended that each document be reviewed before attempting any installation, operation, or maintenance procedures. The documentation for each major component may also contain warnings and cautions identified by the manufacturer of each component. These warnings and cautions may be specific for the particular component, and therefore not covered in this general Installation, Operation, and Maintenance Manual. They should also be carefully reviewed before attempting installation, operation, or maintenance procedures. 2

The combination of electricity and water can pose a very dangerous situation. Assure that all power has been shut off/disconnected and locked out in an appropriate manner, before attempting any installation or maintenance procedures. Areas of potential danger: 1. all electric power leads and connections; 2. all hot/boiler water lines, steam lines, joints, valves, and relief valves; and 3. all joints at valve, gauges, etc. Before attempting any installation, operation, or maintenance procedures pertaining to the unit. 1. assure that the electric power supply has been turned off and locked out in an approved manner; 2. if the unit has been in operation, allow the water in the tank, as well as all components and surfaces (heating elements, hot water outlet lines, etc.) to cool before starting the procedure; 3. assure that all incoming and outgoing water and steam lines have been turned off at the manual shutoff valves; and 4. completely drain the tank, after allowing the water time to cool. Hot/boiler water and steam present a situation that can be very dangerous due to the fact it is under pressure and at very high temperatures. To avoid possible injury or death, use common sense and follow all accepted and recommended procedures when - performing installation, operation, and maintenance procedures. Connecting the Electric Power Source All installation procedures involving electric power connection should only be performed by trained, certified electricians. Hot/boiler water and steam present a situation that can be very dangerous because of the high temperatures and pressures. Use common sense and follow all accepted and recommended procedures when performing installation, operation, and maintenance - procedures to avoid possible injury or death. The combination of electricity and water can pose a very dangerous situation. Assure that all power has been shut off/disconnected and locked out in an approved manner, before attempting any installation or maintenance procedures. The CEMLINE Water Heaters have been wired during assembly. Connecting the electric power supply to the unit consists of connecting the correct voltage, phase, and amperage power leads to the terminal strip or circuit breaker. The exact voltage, phase, and amperage requirements for the unit can be determined from the rating plate affixed to the jacket of the unit, or from the Submittal Sheet and Wiring Diagrams supplied with the unit. 3

The Controller Terminal Layout Connectors G-GO: AC 24 V supply 1. Temperature Sensor Connection M: Ground (GO) for signals, universal 2. Temperature Sensor Connection inputs, analog outputs 3. 0-10 V DC Output Connector X1 and X3: Temperature probe connector 4. Limit Switch Connector Y: Analog output 5. Dump Valve Switch Connector Q(+): Relay output connector 6. 24 V AC Power Supply Adjustments X3 - operating temperature X1 - high limit set point +, info buttons These buttons scroll through the functions codes in a predetermined order. Once the required variable is flashing, these buttons are used to increase/decrease the value. select button Chooses the desired function to be edited and also accepts the user selected values. 4

Main Screen Single Safety System Indication Double Safety System Indication The main screen on the RWD45U controller shows information related to the operating conditions of the water heater. In the lower left hand corner is a display value between 0 and 10 that represents the number of volts DC being sent to the control valve. At 0 volts the valve will be closed and at 10 volts the valve will be fully open. In the lower right hand corner is the display temperature of the water in the heater in degrees Fahrenheit. Above the temperature display are two blocks. The block to the right of X1 indicates the single safety system high limit (sss). The single safety system high limit will cause the main control valve to close if the temperature set point has been exceeded. If the single safety system block is solid on the controller display then the single safety system temperature limit has been exceeded. The single safety system high limit will automatically reset after the temperature drops 3 degrees below the single safety system limit set point. The second block to the right of X1 indicates the optional double solenoid safety system high limit (dsss). When the double solenoid safety system high limit temperature has been exceeded an optional water solenoid opens to dump overheated water from the heater. If the block is solid on the controller display then the double solenoid safety system temperature limit has been exceeded. This limit will automatically reset after the temperature drops 3 degrees below the double solenoid safety system set point. 5

Operating Temperature Set Point Degree F. This is the operating temperature set point of the water heater. The operating temperature is defaulted to 140 o F. Adjusting the Operating Temperature Set Point 1. From the main screen push the + button three (3) times until SP-h appears in the left hand corner of the LCD display. (See the screen image below). y1 F SP-h 140.0 2. Push the select button. This will cause the set point number to blink. 3. Push + or to select the desired operating temperature set point. 4. Push the select button to lock in the set point. When the set point is locked in the number will stop blinking. 5. Push the button three (3) times to go back into the main menu screen or the controller will automatically go back to the main screen after 20 seconds. 6

Single Safety System or Primary High Limit Temperature This is the single safety system or primary high limit temperature that is typically set 10 to 20 degrees higher than the desired operating temperature. When the single safety system or primary high limit temperature has been exceeded the controller will cause the main control valve to close. The single safety system or primary high limit temperature limit is factory set at 150 o F. The single safety system high limit will automatically reset after the temperature drops 3 degrees below the limit set point. Do not set the high limit temperature (SP-c) at a lower temperature than the operating temperature (SP-h). SP-c must be set at least 10 F higher than Sp-h. Adjusting the single safety system or primary high temperature limit 1. Push the + button one (1) time until SP-c appears in the left hand corner of the LCD display and the second box from the right is flashing. The flashing box will have a snowflake over it. (See the screen image below). Flashing * G G F SP-c 150.0 2. Push the select button again. This will cause the set point number to blink. 3. Push + or to select the desired high limit temperature. 4. Push the select button to lock in the set point. When the set point is locked in the number will stop blinking. 5. Push the button one (1) time to go back to the main menu screen or the controller will automatically go back to the main screen after 20 seconds. 7

Double Solenoid Safety System or Secondary High Temperature Limit This is an optionally supplied water solenoid valve. The double solenoid safety system or secondary high limit temperature is typically set 20-30 degrees higher than the desired operating temperature. When the double solenoid safety system or secondary high limit temperature is reached a water solenoid opens to dump overheated water from the heater. The double solenoid safety system or secondary high limit temperature limit is factory set at 160 o F. This limit will automatically reset after the temperature drops 3 degrees below the double solenoid safety system set point. Do not set the secondary high limit temperature (SP-c) at a lower temperature than the operating temperature (SP-h). Secondary SP-c must be set at least 20 F higher than Sp-h. Adjusting the double solenoid safety system or secondary high temperature limit 1. Push the + button two (2) times until SP-c appears in the left hand corner of the LCD display and the first box from the right is flashing. (See the screen image below). Flashing * G G F SP-c 160.0 2. Push the select button. This will cause the set point number to blink. 3. Push + or to select the desired operating temperature. 4. Push the select button to lock in the set point. When the set point is locked in the number will stop blinking. 5. Push the button two (2) times to go back to the main menu screen or the controller will automatically go back to the main screen after 20 seconds. 8

Wiring Diagram M2H and M3P Valves 9

Wiring Diagram MXG and MXF Valves 10

Wiring Diagram MVF Valves 11

Testing the Temperature Sensor The temperature sensor is a nickel RTD sensing element. To test the temperature sensor: 1. Turn the power off to the unit. 2. Remove the temperature sensor connection plug from the controller. 3. Measure the resistance between terminals M and B1 for one probe, and M and B2 for the second probe. 4. Compare the resistance read and the corresponding temperature of the water heater to the chart shown on the right to verify accuracy of the temperature sensor. 5. Replace the temperature sensor connection plug. 6. Turn power back on. Degree Fahrenheit Resistance In OHMS 40 1020 50 1045 60 1070 70 1096 80 1122 90 1148 100 1175 110 1202 120 1229 130 1257 140 1285 150 1314 160 1343 170 1372 180 1402 MXG and MXF Valve Information The MXG and MXF valves can be configured for linear and equal percentage operation. Factory setting is equal percentage. Switch OFF ON 1 Characteristic Linear Equal percentage * 2 Control signal must be in the OFF position 3 Volts or ma must be in the OFF position 12

Valve Calibration The MXG and MXF valves are factory-calibrated at 0% and 100% stroke. When commissioning the valves, however, (especially under extreme conditions of use) there may still be some leakage via control path A >AB (below, and marked on the valve). In this case, the valve can be recalibrated simply and quickly as follows. Remove the screws from the top of the electrical housing on the control valve and remove the cover. Using a pointed implement (2mm diameter) to operate the button in the opening [A] in the terminal housing. While recalibration is in progress, the LED [B] in the electronics module will flash green for approximately 10 seconds. The valve will be briefly closed and fully opened. Warning The two-color LED display [B] indicating operating status can be viewed by opening the cover the the electronics module. LED green On continuously Automatic mode: Auto (normal, no faults) Flashing Mechanically set to Manual Mechanically set to Off Currently in Calibration mode LED red On continuously General fault General calibration error Microcontroller fault Flashing Faulty AC 24 V supply (e.g. too low) LED Off No AC 24 V supply Faulty electronics module As a general rule, the LED can assume only the states shown above (continuously red or green, flashing red or green, or off). The control valve has a hand wheel knob on the top of the valve (see diagram below). This control knob must be placed into the automatic position (AUTO). The AUTO position allows automatic control of the valve to occur. By placing the hand wheel in the OFF position the valve will not close. Do not place the wheel in the manual position. By placing the wheel in the manual position prevents the control program to function correctly and is dangerous to the operation of the unit. The hand wheel knob must be in the auto position. 13

Valve Calibration M3P and M2H Valve Information The M3P and M2H valves are factory-calibrated at 0% and 100% stroke. When commissioning the valves, however, (especially under extreme conditions of use) there may still be some leakage via control path 1 >2 for the M2H and 1 >3 for the M3P (see below, and marked on the valve) with a 0% stroke control signal (DC 0V, DC 4 ma or DC 2 V). In this case, the valve can be recalibrated simply and quickly as follows. Remove the left screw of the electronic module also known as the ZM module. Use a pointed implement (2mm diameter) or a screwdriver No. 0 or 1 to push in the switch in the electronics module (see below). While recalibration is in progress, the LED in the electronics module will flash green for approximately 10 seconds. The valve will be briefly closed and fully opened, full stroke is maintained for 1 to 3 seconds and the valve closes again. The valve will then go to the position which corresponds to the position signal. If the LED continues to flash after 10 seconds there was an error in operation during the calibration process or there is another fault. M2H M3P 14

MVF Valve Information The MVF valve can be configured for linear and equal percentage operation. Factory setting is equal percentage. Switch OFF ON 1 Volts or ma must be in the OFF position 2 Correcting span must be in the OFF position 3 Characteristic Equal percentage * Linear Valve Calibration The MVF valves are factory-calibrated at 0% and 100% stroke. When commissioning the valves, however, (especially under extreme conditions of use) there may still be some leakage via control path A >AB and the valve s electronics must be recalibrated. To recalibrate, the hand wheel must be set into the automatic position (AUTO). Remove the screws from the top of the electrical housing on the control valve and remove the cover. The printed circuit board has a slot for calibration (see diagram below). Calibrate by bridging the contacts located behind the slot on the printed circuit board, using a screwdriver. The valve will then travel across the full stroke to store the end positions. While recalibration is in progress, the LED [A] in the electronics module will flash green for approximately 10 seconds. The valve will be briefly closed and fully opened. The valve will then go to the position which corresponds to the position signal. If the LED continues to flash after 10 seconds there was an error in operation during the calibration process or there is another fault. 15

The two-color LED display [A] indicating operating status can be viewed by opening the cover the the electronics module. Indication Operating State, Function Remarks, Troubleshooting Green Red Lit Control mode Normal operation; everything OK. Flashing Lit Flashing Calibration In manual control Calibration error Internal error Main fault DC Supply - / + Both Dark No power supply Electronics faulty Wait until calibration is finished (green or red LED will be lit) Hand wheel in Man or Off position Recalibrate (bridge contacts behind the calibration slot) Replace electronics module Check electric main network (outside the frequency or voltage range); VDC supply +/- connection polarity Check electric main network, check wiring Replace electronics module Warning The control valve has a hand wheel knob on the top of the valve (see diagram below). This control knob must be placed into the automatic position (AUTO). The AUTO position allows automatic control of the valve to occur. By placing the hand wheel in the OFF position the valve will not close. Do not place the wheel in the manual position. By placing the wheel in the manual position prevents the control program to function correctly and is dangerous to the operation of the unit. The hand wheel knob must be in the auto position. 16

General Valve Information The valve is factory assembled and does not require repacking or other periodic service. Testing 1. Remove power from the controller by removing the orange connector at pins GO, G, G which is connector (3) on page 4. 2. Remove the control module from the valve by loosening the two mounting screws. 3. Measure the resistance between the two terminals indicated on the drawing on page 12. Also see chart on page 12 for resistance for valve coil. Look on valve for the model number that corresponds with the chart. 4. Check one of above terminals to ground. The resistance should be infinite. 5. Measure the voltage at 24 volt transformer between wires 2 and 9 on the wiring diagrams from pages 6 and 7. 6. Reconnect the control module. 7. Reconnect the power to the controller. 17

Magnetic Coil Resistance Information Valve Model Actuator Coil Resistance (Ω) M2H15F 21 M2H20FY 21 M2H25FY 21 M2H32FY 15.3 M2H40FY 10 M2H50FY 10 M3P80FY 5.187 1) Magnetic Coil Resistance (KI. 7+8) M3P100FY 3.34 Diagram A 1. Remove the screws from the top of the electrical housing on the control valve and remove the cover. 2. Using a 3 mm Allen wrench remove the 3 Allen head screws (S) which hold the electronic module to the control valve housing (see diagram A). 3. Measure the magnetic coil resistance across the two exposed terminals (see diagram B) and compare the resistance to the chart below. 4. Carefully re-install the electronic control module and cover. Valve Model Actuator Coil Resistance (Ω) MXF461.15 9.2 MXF461.65 4.87 MXG461.25 9.2 MXG461.32 9.2 MXG461.40 5.55 Diagram B MXG461.50 5.55 MXG461.15 9.2 Magnetic Coil Resistance (Stem stroke length cannot be measured) 18

Notes 19

CEMLINE CORPORATION P. O. BOX 55 CHESWICK, PENNSYLVANIA 15024 Phone: (724) 274-5430 FAX (724) 274-5448 www.cemline.com