KVAR POWERHOUSE RANGE 140 KVA 200 KVA 50 hz Three phase - 415 v Model Engine Manufacturing Alternat PRP Output ESP Output country of engine or and alternator Kva Kw Kva Kw PM140 1106A-70TG1 ECP34-2L UK 138 110 152 121 PM150 1106A-70TAG2 ECP34-2L UK 150 120 164 131 PM180 1106A-70TAG3 ECO38-1SN UK 180 144 196 156 PM200 1106A-70TAG4 ECO38-2SN UK 200 160 220 176 PS135 1106A-70TG1 UCI274E UK 135 108 150 120 PS150 1106A-70TAG2 UCI274F UK 150 120 165 132 PS180 1106A-70TAG3 UCI274G UK 180 144 198 158 PS200 1106A-70TAG4 UCI274H UK 200 160 220 176 Ratings definitions: Ratings are in accordance with ISO8528 and are based on a 25 Deg C ambient air inlet temperature, 100 M altitude and 30% relative humidity and are based on 0.8 lagging power factor. Prime Power (PRP) Power available at variable load, with a load factor not exceeding the figure shown. An overload of 10% is permitted for 1 hour in any 12 hours operation. Standby Power (ESP) Power available at variable load in the event of a main power network failure upto a maximum of 500 hours per year. No overload is permitted.
Data 1106A-70TG1 1106A-70TAG2 1106A-70TAG3 1106A-70TAG4 Performance class ISO8528 G2 G2 G2 G2 Average load factor % of PRP 80 80 80 80 Load acceptance % of PRP 90 70 67 62.5 Hz regulation % +/-0.75 +/-0.75 +/-0.75 +/-0.25 constant load Voltage regulation % +/-1 +/-1 +/-1 +/-1 Cooling clearance Deg C 53 53 53 53 Fuel tank capacity Open Canopied 397 397 397 533 Fuel consumption Litres/hour 50% 75% 100% 110% 16.2 22.7 29.6 32.9 16.4 24.3 32.6 35.3 19.7 30.6 39.6 43.4 23.2 34.1 44.6 48 Fuel consumption is based on fuel in accordance with BS2869 with a specific gravity of 0.845 and is subject to a +5% tolerance Cylinders 6 6 6 6 Configuration Inline Inline Inline Inline Aspiration ` Turbocharged Turbocharged Air/air charge cooled Turbocharged Air/air charge cooled Turbocharged Air/air charge cooled Compression ratio 18.2:1 18.2:1 18.2:1 18.2:1 Bore x stroke mm 105x135 105x135 105 x 135 105 x 135 Displacement Litres 7 7 7 7 Mean piston speed m/sec 6.8 6.8 6.8 6.8 Thermal efficiency % 39.4 39.7 38.7 38.6 (PRP) BMEP (PRP) kpa 1411.7 1522.1 1856.8 2041.8 Cooling capacity Litres 21 21 21 21 Lub. oil capacity Litres 16.5 16.5 16.5 16.5 Airflow M3/min 252 252 252 252 Duct Pa 125 125 125 125 Exhaust gas flow (ESP) M3/min 22.66 25.53 33.85 36.8 Exhaust back pressure kpa 6 6 6 6
UCI274E UCI274F UCI274G UCI274H Avr model SX460 SX460 SX460 SX460 Bearings 1 1 1 1 Stator insulation Class H H H H Rotor insulation Class H H H H Temperature rise PRP ESP Winding pitch 2/3 2/3 2/3 2/3 Number of leads 12 12 12 12 Mechanical protection IP23 IP23 IP23 IP23 THF <2 <2 <2 <2 Inertia Kgm2 1.32 1.55 1.76 1.93 ECP34-2L ECP34-2L ECO38-1SN EC038-2SN Avr model DSR DSR DSR DSR Bearings 1 1 1 1 Stator insulation Class H H H H Rotor insulation Class H H H H Temperature rise PRP ESP Winding pitch 2/3 2/3 2/3 Number of leads 12 12 12 12 Mechanical protection IP21 IP21 IP21 IP21 THF <2 <2 <2 <2 Inertia 1.11 1.11 1.72 1.87
Scope of standard supply Cooling system Induction system Governor type Fuel system Lubrication system DC electrical system Baseframe Control panel Set mounted tropical radiator- original Perkins supply Engine driven cooling fan Fan and matrix protection guard Dry paper element air filter Pressure drop indicator Mechanical PM/PS200 Electronic Fuel filter Fuel lines Contents gauge Vent and drain Lub oil filter Sump drain pump (optional on open sets) Standard on all canopied sets 12 v starter motor 12 v charge alternator 1 x 125 amp/hour lead acid maintenance free batteries Steel baseframe with integral steel fuel tank Powder coated steel enclosure flexibly mounted above alternator terminal box Controller DSE 7120 Circuit breaker Monitoring Exhaust Works Test Paint colour Powder coated steel enclosure fitted to gen set 3 pole MCCB Oil pressure Engine temperature Engine speed Hours run Amps per phase Ac voltage Frequency Mains ac monitoring Maintenance scheduler Industrial exhaust silencer Flexible exhaust section Full works test In accordance with ISO8528 covering Functions Load tests upto 110% Load acceptance capability Conducted at unity power factor Black
Canopy specifications Our canopies are designed and manufactured in Western Europe to our own specifications and share the following in common: Acoustic & weatherproof Galvanised steel Stainless steel door handles Gloss powder coat Zinc plated door hinges Neatly fitted fireproof (DIN75200) soundproofing materials Detachable air inlet and outlet attenuators allows access to radiator and maximises the space available when loading multiple sets into containers for shipment. Prototype tested to ensure cooling clearance Sound attenuation Dba@ 1m 85 Ambient cooling clearance Deg C 50 Thickness of steel mm 2 IP rating IP44 Access Combination of hinged doors and bolted panels Access points Viewing window Cable gland plate Radiator filler Exhaust position Lifting facilities Roof mounted Single point lifting frame Forklift access from base Colour Canopy RAL9010 White Base Galvanised We can also offer Custom built soundproof canopies designed for specific applications
Options Each set within the KVA Powerhouse range can be supplied with a number of options to tailor the set to a specific duty. Mains coolant heater Permanent magnet excitation Alternator anti condensation heaters Alternator winding thermistors Alternator winding and bearing RTD s High specification fuel/water separator with alarm contact Single point exhaust temperature monitoring DSE7220 controller DSE7320 controller DSE8610 controller Assists starting and load acceptance capability at low ambient temperatures Improves motor starting and voltage regulation Minimises damage to the windings caused by condensation build up Provides alarm/shutdown for high winding temperature Provides temperature readout of windings and bearing(s) Minimises damage to fuel systems and provides alarm indication Provides a temperature readout Enables remote communications Enables synchronising Remote monitoring and control 4 pole mccb Motor operator Earth fault protection 5 amp or 10 amp battery charger Battery temperature monitoring Automatic Transfer Switch panel Bypass switch panel Synchronising Custom built enclosures High attenuation enclosures Using either Contactors or circuit breakers Available either between generators or between generator and mains Purposely designed tailor made canopies for specific installations such as water authorities 65 dba @ 1m for Hospitals and residential installations Critical exhaust silencer systems Bunded base fuel tank Ce compliance and certification Required for EC countries Required for EC countries
Further options are shown in our current price list. Weights and dimensions The following is given for guidance. For installation purposes we can supply as built drawings OPEN SETS Model Length Width Height Dry weight Cm Cm Cm kg PM140 221 76 157 1550 PM150 232 76 167 1615 PM180 251 82 167 1635 PM200 251 82 167 1685 PS135 221 76 159 1550 PS150 233 76 168 1650 PS180 251 82 166 1700 PS200 251 82 166 1745 CANOPIED SETS Model Length Width Height Dry weight Cm Cm Cm kg ALL MODELS 363 102 194 Open set + 450 kg KVA Power Installations Ltd Tel 01942386237 sales@kvapower.co.uk www.kvapower.co.uk We have a policy of continuous product development and reserve the right to alter specifications without notice July 2016 Issue 1