ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

Similar documents
ZS4-SF1 Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

ZS4-D2-S-T Screw Clamp Terminal Blocks Double deck with 1 disconnect circuit with test socket screws and 1 feed-through circuit

ZS4-SF Screw Clamp Terminal Blocks For 5 x 20 fuses

ZS4-S Screw Clamp Terminal Blocks Disconnect with blade

ZS35-PEN Screw Clamp Terminal Blocks Ground + Neutral

ZS35 Screw Clamp Terminal Blocks Feed-through

ZS6-3S Screw Clamp Terminal Blocks Feed-through with 3 connections

ZS6-D1-PE Screw Clamp Terminal Blocks Double deck with 1 ground circuit

ZS4-D-CH Screw Clamp Terminal Blocks Component holder

ZS10-ST Screw Clamp Terminal Blocks Test disconnect with sliding link

ZS6 Screw Clamp Terminal Blocks Feed-through

ZS10-PE Screw Clamp Terminal Blocks Ground

ZS10-S-R2 Screw Clamp Terminal Blocks Disconnect with lever

ZS4-PE Screw Clamp Terminal Blocks Ground

ZS50-PE Screw Clamp Terminal Blocks Ground

ZK2.5-D-CH PI-Spring Terminal Blocks Component holder

ZK2.5-SP PI-Spring Terminal Blocks Disconnect with plug - with test sockets

ZK2.5-SF-R PI-Spring Terminal Blocks For 5x20 fuses - with blown fuse indicator

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator

ZK4-PE PI-Spring Terminal Blocks Ground

ZS4 Screw Clamp Terminal Blocks Feed-through

ZK2.5-4P PI-Spring Terminal Blocks Feed-through with 4 connections

ZK2.5-D1-PE PI-Spring Terminal Blocks Double deck with 1 ground circuit

ZS6-4S Screw Clamp Terminal Blocks Feed-through with 4 connections

ZK6 PI-Spring Terminal Blocks Feed-through

ZS4-PE Screw Clamp Terminal Blocks Ground

ZS4-T3 Screw Clamp Terminal Blocks Triple deck with 3 feed-through circuits

ZS10 Screw Clamp Terminal Blocks Feed-through

ZK4-4P PI-Spring Terminal Blocks Feed-through with 4 connections

ZK2.5-4P PI-Spring Terminal Blocks Feed-through with 4 connections

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator

ZK2.5-PE-4P PI-Spring Terminal Blocks Ground with 4 connections

ZS6 Screw Clamp Terminal Blocks Feed-through

ZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket

ZDP Pluggable Terminal Blocks Feed-through

ZP2.5-PE Spring Terminal Block Ground

DBL distribution blocks 3x1 pole

ZP2.5-4P Spring Terminal Block Feed-through

ZS4-SF1 Screw Clamp Terminal Block

Main catalogue. SNK Series Terminal Blocks Accessories Marking Solutions

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Main catalog. SNK series Terminal blocks. Phone: Fax: Web: -

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

Electronic overload relay EF65, EF96 and EF146

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Electronic overload relays EF205 and EF370

Thermal overload relay TF140DU and TF140DU-V1000

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

Thermal overload relay TF65 and TF96

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

Manual motor starter MS116

Mini contactors B6, BC6 with 3 pole

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

Thermal Overload Relays

MS General Information Extended Product Type: MS

Manual motor starter MS132

Manual motor starter magnetic only MO325

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Manual motor starter MS116

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

DX³ RCCBs - ID 4P up to 100 A

Manual motor starter MS132

AF40... AF96 3-pole contactors Technical data

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

Manual motor starter MS132

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

RX 3 M.C.B A up to 63 A

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

RX 3 M.C.B A up to 63 A

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Phase + Neutral, neutral on left side

ABB i-bus KNX DG/S x DALI-Gateway Basic

TX³ RCCBs 2P up to 100 A

up to 63 A (1 module per pole)

Voltage limiting device HVL

Data sheet... W-Series WPE 4

Viking 3 - Screw connection Disconnect terminal blocks

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1NQ

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

Data sheet. W-Series WDU 4 SL/EN

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Brochure. Motor protection and control DRAS enclosed direct-on-line starters

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

Surge arrester POLIM-H..SD

Voltage limiting device HVL

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

Transcription:

Technical Datasheet SNK646D00 Catalogue Page ZS6-S Screw Clamp Terminal Blocks Disconnect with blade - Ease your disconnect operations with the disconnect blade operated by hand or with a screwdriver, - Same profile as ZS6 feedthrough terminal block for aligned marking and identical end section use. SNK656F004 SNK06F0000 3D CAD outline drawings available on "Control Product 3D" portal SNC0 F0000 Screw Clamp Terminal Blocks 6 mm² AWG 6 mm 0.36 in Spacing Ordering Details Color Grey Blue Grey Blue Type ZS6-S ZS6-S-BL Order Code SNK635R0000 SNK63R0000 EAN Code 347596354 3475963 Pack (ing) Weight ( pce) g 8.60 8.60 Declarations and Certificates CE CB RoHS USR CSA EAC BV DNV

Declarations and Certificates CE CE CB CB RoHS RoHS USR USR SND5U* SND685A0* SND3049F0* SND64A0* CSA CSA SND670A0* EAC EAC SND609A* BV DNV BV DNV SND673A0* SND687A0* Explosive Atmosphere: ATEX Classification Group Category Protection Method In the presence of explosive dust atmosphere, terminal blocks are to be installed in certified enclosure II D General Information Wire stripping length TH 35-7.5, TH 35-5 Denudage IP0 TH 35-7.5, TH 35-5 NEMA Ex e: increased security The following information must be strictly adhered to in order to guarantee the terminal block electrical, mechanical and environmental performance. Protection Rail IEC 60947-.5 mm 0.4 in Operating tool Torque Flat screwdriver Tete de viscouple Screw clamp Flat screwdriver 4 mm 0.57 in 0.85 N.m 7.5 N.m ± 0.5 N.m ±.33 N.m Screw rail contact (Maximum value) Disconnect device Material Specifications Insulating material CTI Flammability Polyamide 600 V UL94 V0 NF F 6 IF Connecting capacity per clamp Rigid - Solid / Stranded conductor Flexible conductor Flexible conductor with non insulated ferrule Flexible conductor with insulated ferrule Gauge Ferrule maximum outer diameter or conductor insulation maximum outer diameter 0.... 6 mm² 0.... 6 mm² 0.... 6 mm² 0.... 4 mm² A4-B3 IEC 60947- Needle flame testec 6065--5 Compliant Screw clamp 4... AWG 4... AWG 4... AWG 3 mm 0.8 in Ferrule 5.5 mm 0.6 in The "Connecting capacity with ferrule" data is guaranteed with ABB crimping tool PS-3 (crimping capacity up to mm²). Technical Datasheet SNK646D00 ABB

Multi Connecting capacity per clamp Rigid - Solid / Stranded conductors 0.....5 mm² 4... 4 AWG Flexible conductors 0.....5 mm² Flexible conductors with twin ferrule 0.....5 mm² 4... 4 AWG Don't mix solid and flexible conductors in the same clamp Don't mix solid or flexible conductors of different sizes in the same clamp The "Connecting capacity with ferrule" data is guaranteed with ABB crimping tool PS-3 (crimping capacity up to mm²) Cross section Rated cross section 4 mm² AWG Maximum Cross section 6 mm² AWG Electrical characteristics Current Rated current 5 A Field and factory wiring Cat. UL 59 5 A Factory wiring Cat. UL 59 5 A CSA-C-. n 58 Maximum Exe current IEC/EN 60079-7 Rated short-time withstand current s (Icw) 480 A Short-time withstand current 0.5 s 5 s s 30 s min Rated short-circuit withstand current UL 59 Max. current (45 temperature increase) / Max. cross section (mm²) 30 A Maximum short circuit current (s) 480 A 6 mm² Short Circuit Current Rating (SCCR) SA UL 59 supplement SCCR UL 59 With the following configurations: Suitable conductor wire range Maximum voltage Fuse class / Max. amp. Rating J T RK RK5 G CC Voltage Rated voltage IEC 60947-0 V Rated voltage UL 59 300 V Use Group UL 59 B, C Rated voltage CSA-C-. n 58 300 V Rated voltage Ex e IEC/ EN 60079-7 Rated impulse withstand voltage IEC 60947-6000 V Dielectric test voltage IEC 60947-890 V Pollution degree IEC 60947-3 Overvoltage category IEC 60947- III ABB Technical Datasheet SNK646D00 3

Temperature range Ambient temperature min/max Storage -55... + C Installing -5... +40 C Service -55... + C -67... +30 F +3... +4 F -67... +30 F Current Derating curve for continuous service temperature Dissipated power Maximum dissipated power at rated current Maximum dissipated power at maximum Exe current IEC 60947-0.8 W IEC 60079-7 Rated power dissipation at an ambient temperature of 3 C - IEC 60947-7-3 Separate arrangement / Overload and short-circuit protection Separate arrangement / Exclusive short-circuit protection fuse and 4 feed-through blocks Compound arrangement / Overload and short-circuit protection Compound arrangement / Exclusive short-circuit protection 5 fuse blocks Environmental Characteristics Additional climatic tests Dry heat Cyclic damp heat Cold Damp heat steady state IEC 60068- Compliant Temperature +0 C 96 h IEC 60068-30 Compliant Temperature +55 C Relative humidity Number of cycles ( cycle = 4h) IEC 60068- Compliant Temperature -40 C 96 h IEC 60068--78 Temperature Relative humidity Corrosion Salt mist IEC 60068- Compliant 96 h Concentration 5 % SO ISO 6988 Compliant 48 h Concentration 0. dm³ Flowing mixed gas corrosion test IEC 60068-60 Number of the test method 4 Technical Datasheet SNK646D00 ABB

Vibrations and shocks Sinusoidal vibrations IEC 60068--6 Compliant Frequency range... 55 Hz Number of cycles Acceleration m/s² Functional random vibrations IEC 6373 Category Class B 3 axes Frequency range Acceleration Long life testing at increased random vibrations Category Class B 3 axes Shock Category Class B 3 axes ZS6-S Terminal Block Accessories Compatibility Some accessories may modify the terminal block's rating. See complete information in the accessories catalog page. IEC 6373 Frequency range Acceleration IEC 6373 Acceleration Description Type Order Code Pack (ing) Weight pieces g ( pce) MG-CPM 3 SNB0479R06 680 0.73 3 4 4 5 6 7 7 8 9 End Sections End Stops End Stops Circuit Separators Shield Connectors Protecting Covers Protecting Covers Protecting Cover Kits Tools MC6 MC6-YL MC6PA UMH PROCAP6 SAT6 PR3.G PR4 PR5 PR30 PR3.Z ES4 BAM4 BAZ CS-R SHBS CO PL6 KCO PS-3 PC6- PC6- PC6-3 PC6-4 SNK000R0000 SNK004R0000 SNK59999R0000 SNK9006R0000 SNK9006R0000 SNK90065R0000 SNA64800R0300 SNA680R0 SNA68700R00 SNA730R00 SNA74300R700 SNK59R0000 SNK90000R0000 SNK90000R0000 SNK9003R0000 SNK900600R0000 SNK900604R0000 SNK90069R0000 SNK90064R0000 SNK9006R0000 SNA3546R400 SNA3548R600 SNA6536R00 SNA6537R0600 0 0 5 0 0 0.00.00.00 0.0 0.80 6.00 78.00 95.00 700 38.00 78.00.0 4.00 5.30 5.0 3. 300.00.80 47.80 380.00.00 8.00.00 3.00 ABB Technical Datasheet SNK646D00 5

Contact us ABB France Electrification Products Division PG Connection 3, rue Jean Perrin F-69687 Chassieu cedex / France Tel. +33 (0)4 7 7 Fax +33 (0)4 7 935 Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 0 ABB All rights reserved SNK646D00 - PDF