CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2

Similar documents
Lighting: Explosionproof Area HID. Applications. Standard Materials

Applications. Standard Materials

Applications. Standard Materials. Certifications and Compliances

HID/AREA: NEC/CEC EXPLOSIONPROOF. Applications. NEC/CEC Certifications and Compliances

Applications. Standard Materials. Certifications and Compliances

Code Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit.

G1-1. HID Lighting Fixtures: Explosionproof, Dust-Ignitionproof. Page Description

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF. Applications. Options

LIGHTING: EXPLOSIONPROOF FLOODLIGHT. Applications. Options

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2 3/4 CAP-75 1 CAP-100

Applications. Straight Stanchion-Mount Fixture with Prismatic Glass Refractor and Guard. Pendant Mount Fixture with Prismatic Glass Refractor

Mercmaster II HID Luminaires High Pressure Sodium and Pulse Start Metal Halide. Mogul Base UNILETS for Use with Threaded Metal Conduit.

G1-24. Applications UL listed for marine type electric fixtures--outside. Ideal in Class I, Div. 1 and 2 installations

SXPJ SERIES S X. HID & Compact Fluorescent Lighting for Hazardous and Hostile Locations

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D)

SXPJ SERIES S X azz.com/rigalite

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations.

Applications. Illustrated Features

FV Series Nonmetallic Fluorescent Luminaires For Hazardous and Adverse Locations

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

N2MV Series W Non-metallic

Areamaster 100 Wide-Beam Floodlights 70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH For general, marine and hazardous locations.

Areamaster LED Flood/High Bay Luminaires

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

F1-1. HID Lighting: Enclosed and Gasketed. Description. 2, 3 Mercmaster III Family Tree Mercmaster III HID Low Profile Lighting Fixtures

MHD2/MHDO SERIES MHD2. Marine Heavy Duty Outdoor Non-Metallic Fluorescent CLASS 1 DIVISION 2 FLUORESCENT LIGHT

DMV Series W For Combustible Dusts

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

MHD2/MHDO SERIES M H D 2. Marine Heavy Duty Non-Metallic Fluorescent

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W, 1000 W HID Light Level Equivalent

MHDS SERIES M H D S. Stainless Steel Marine Heavy Duty Luminaire for Hazardous Locations

SAFR LED SERIES S A F R L E D. Hazardous Location LED Luminaire

Industrial Areamaster LED Flood/High Bay Luminaires For Ordinary Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

MAR SERIES Fluorescent Lighting for Hazardous Locations

Standard Grade 14 Inch Reflector. Ordering Information

WFH LED SERIES L E D. High-Bay Lighting for Hazardous & Wet Locations

N2LED Series Emergency Luminaires Non-Metallic Emergency Egress Lighting Systems with Remote or Direct Mounted Lamps.

PGL350P W PS Wallpack

Fluorescent Lighting: Enclosed and Gasketed

KH Series Kemlux III Enclosed/Gasketed

INCANDESCENT/COMPACT FLUORESCENT/MEDIUM BASE HID

SAFJ LED SERIES S A L E D. Hazardous Location Compact LED

Post Top Globes. ACL Large Acorn Post Top Globe Page 109. ACS Small Acorn Post Top Globe Page 109

Form 85 Unilets Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit.

WFHN LED SERIES W F H N L E D. High-Bay Lighting for Heavy Hose-Down Environments

AFL FLOODLIGHT SERIES

TORNADOTM BOLLARD PATENTS PENDING

MOGUL BASE HID FIXTURES

Standard Grade 23 Inch Reflector/Refractor. Ordering Information. series wattage source voltage optics color options options BL-LB1

Perimaliter Wallpacks

Champ Fixtures. Class I, Division 2 Class I, Zone 2. Floodlight

1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens

45 Degree Surface Mount Explosion Proof, Waterproof Fluorescent Lights -Paint Booth, Rigs - 2 Lamp

Low brightness and uplighting combine to create a pleasing visual environment. Softbay Series

SAFR LED S A F R L E D. LED Area Lighting for Hazardous Locations

Industrial Mercmaster LED Low Profile Luminaires For Ordinary Locations

Perimaliter Wallpacks

NMF 2 SERIES Non-Metallic Enclosed and Gasketed Fluorescent Lighting for Wet and Damp Locations

RSS SERIES R S S. Fluorescent Lighting for Hazardous Locations

Surface Mount Explosion Proof, Waterproof Fluorescent Lights - T12 Very High Output - Oil Rigs - 2 L

COMPACT FLUORESCENT EMERGENCY FIXTURES

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP038A0712

WPP25 250W MP Wal-Pak Borosilicate Glass Hinged/Removabl

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount

FM9 Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

Haz. HazMax Summit/ss TECHNICAL SPECIFICATIONS

Induction Compact Fluorescent HID LPQ. Canopy Luminaire

A R C H I T E C T U R A L LO W L E V E L F LO O D L I G H T S E R I E S

Champ MLL LED luminaires

Aluminum Conduit Bodies, Covers and Gaskets For Rigid Conduit & IMC.

1000 Watt Metal Halide Flood Light - 110,000 Lumens - Slipfitter Mount - 120~277 Volts AC

Rig-A-Lite LED Luminaire Guide. Superior LED Technology for Hazardous and Severe Environments. Five-Year Warranty

AerolumeTM. Collection. Area Luminaires 3 Fixture Sizes W HID 64/80/120

XPF. XPFMax Performer/al FEATURES TECHNICAL SPECIFICATIONS

Cynergy Series Retrofit Kit

The ideal complement for commercial and retail spaces where users will appreciate classic interpretations of style and elegance. Kaleidoscope Series

APPLICATIONS APPROVALS. GASKET One piece neoprene. LATCHES Plated steel twist draw. ENTRIES 1 2 NPT feed-through outlets, 3 4 NPT outlets optional.

Understanding Electronic UltraMax HID Ballasts

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style (fluorescent replacement)

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof

2 LED Designer Series

KAD250MR3TBSPD04 Wall Fixture

Variety of mounting methods. UL, CUL, and CSA listed for general and hazardous locations

Class 1 Division 2 Hazardous Location LED Light - Corrosion Resistant for Marine (Saltwater) - Offsh

KEMLUXIII KH SERIES HAZARDOUS LOCATION

Fixture Spec Sheet HFA2 Series 4/15/2011


Linear Fluorescent Highbays. A comprehensive selection of high output commercial/industrial fluorescent lighting


Class I, Div. II Fluorescent Fixture - Emergency Battery Backup - Corrosion Resistant (Saltwater) -

Potenza Commercial Pendant Compact Fluorescent, Incandescent, HID Medium, Large

FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

Class I Division 2 LED Pivoting Light - 4 foot 3 lamp - LED Oil Rig Fluorescent Replacement

Test Sample Description Catalog Number: Description:

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

DuraPro Hazardous Area Fluorescent

Transcription:

Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 75 W PSMH. 75 W MH. Medium Base. For Use with Threaded Metal Conduit. Applications For use in chemical and petrochemical plants, such as manufacturers of plastics, paints and thinners; in refineries; and in other areas where ignitable vapors, dust, moisture and corrosive elements may be present. Suitable for outdoor saltwater locations and for other wet locations. Features Fixtures operate safely in high ambient temperatures. Arrangement of heat-producing components results in efficient heat dissipation for cooler fixture operation. Patented wireless design. Threading of fixture unit onto mounting hood makes electrical connection. Only wiring required is attaching two wires to connection block in mounting hood. Connection block is easily wired: (a) loosen two screws, (b) make wire connections, and (c) re-position connection block. Safe, easy servicing without disconnecting any wiring. Wireless fixture unit threads off mounting hood for convenient servicing or for immediate replacement with a stand-by unit. Acme double-lead threads speed installation and fixture removal from mounting hood only half as many turns are required as for single-lead threads. The threads do not stick or gall, eliminating problems often encountered with single-lead threads during fixture unit removal. All threaded joints are flame-tight. Integrally ballasted HID lighting fixtures; separate ballasts not required. Factory sealed. External seals not required for Groups C and D. Fixtures for use in NEC Group B locations furnished complete with UL required sealing fitting. Not required for CEC approval. Strategic location of lamp socket, in combination with interior prism design of the glass globe, provides optimum light distribution and control. Heat and impact-resistant globes have smooth dust-resistant exterior. Superior corrosion resistance, with epoxy powder coat finish. Shock-absorbing medium-base socket mounts prolong lamp life. Porcelain socket with nickel-plated phosphor bronze screw shell. Assures long trouble-free operation in high ambient areas. Choice of mountings: pendant, ceiling, bracket and stanchion. Fiberglass-reinforced polyester reflectors, in standard dome, or 30 angle styles, are ideal in installations where luminaire is subject to exceptionally severe corrosive atmospheres. Optional guards protect globes from damage. Secured to fixture with three stainless steel screws. Variety of light sources: high pressure sodium, pulse start metal halide and metal halide. HPS is excellent where long lamp life is required. HPS provides high lumens per watt and is less expensive to operate. PSMH and MH are desirable where colors in illuminated areas must be close to natural. A wide range of ballasts and voltages are available for both domestic and export applications. Ballasts operate at low temperatures PSMH/MH: -29 C (-20 F); HPS: -40 C (-40 F). 50 W through 50 W high pressure sodium ballasts are high reactance, high power factor type. Standard Materials Ballast bodies and guards: copperfree (4/0 of % max.) aluminum Pendant mounting hoods: diecast copperfree (4/0 of % max.) aluminum Ceiling, bracket and stanchion mounting hoods: sand cast copperfree (4/0 of % max.) aluminum Reflectors: fiberglass reinforced polyester Standard Finishes Ballast bodies, guards and mounting hoods: epoxy powder coat finish, electrostatically applied for complete, uniform corrosion protection Options Fuses: order fuses for field installation by catalog number, see Ballast and Fuse Kit Data. Hot Restrike add suffix -R. Smart Starter add suffix -S. Emergency Options available for 50 W through 50 W HPS only. For CEC Exd IIB + H2 rating, add suffix -Z. For safety chain, add suffix -SC. NEC/CEC Certifications and Compliances UL Standard: UL 598, UL 844 UL Listed: E0444 CSA Standard: C22.2 No. 250, C22. 2No. 37 CSA Certified: 025428 Visit our website at www.emerson.com or contact us at (800) 62-506. September 207 363

Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 75 W PSMH. 75 W MH. Medium Base. For Use with Threaded Metal Conduit. +40 C (+04 F) +55 C (+3 F) +65 C (+49 F) +40 C (+04 F) Lamp Watts Ballast Type Ambient Temp. T Numbers Supply Wire Temp C ( F) Ambient Temp. T Numbers Supply Wire Temp C ( F) Ambient Temp. T Numbers Supply Wire Temp C ( F) Ambient Temp. T Numbers Supply Wire Temp C ( F) High Pressure Sodium Medium Base Lamps 50 MT, TT T6 75 (67) T5 75 (67) T4A 75 (67) T4 75 (67) 70 MT, TT, 480 V T5 75 (67) T4A 75 (67) T4A 75 (67) T4 90 (94) 00 MT, TT, 480 V T4A 75 (67) T4 90 (94) T3B 90 (94) 50 MT, TT, 480 V T3C 75 (67) Pulse Start Metal Halide Medium Base Lamps 75 MT, TT, 480 V T3B 90 (94) Metal Halide Medium Base Lamps 75 MT, TT, 480 V T3B 85 (85) T Numbers Represent the Maximum Surface Temperature for Class I, Division Locations and Maximum Surface Temperature Under Dust Blanket for Class II, Division Locations. T Number T 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6 Temp. Range ( C) 35-450 326-350 30-325 28-300 26-280 23-260 26-230 20-25 8-200 66-80 6-65 36-60 2-35 0-20 86-00 85 Temp. Range ( F) 664-842 69-662 574-67 538-572 502-536 448-500 42-446 394-49 358-392 33-356 322-329 277-320 250-275 24-248 87-22 85 Fixture and Accessory Weights kg (lb) Fixture Size Fixture Weight Reflector Weight Guard Weight 50 W thru 75 W 2.70-4.5 (28-32).36 (3) 0.45 () Mounting Hood Weights kgs (lbs) Pendant Ceiling Bracket Stanchion 0.9 (2).8 (4) 2.72 (6) 0.9 (2) NOTE: The maximum operating temperature of the fixture must not exceed the ignition temperature of the gas, vapor or dust to be encountered per the National Electrical Code and the Canadian Electrical Code. MT is Multi-Tap for 20/208/240/277 V, TT is Tri-Tap for 20/277/347 V. Class I, Division Locations. Class II, Division Locations. 364 Visit our website at www.emerson.com or contact us at (800) 62-506. September 207

Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 75 W PSMH. 75 W MH. Medium Base. For Use with Threaded Metal Conduit. Type Mounting Pendant - One Hub, Rigid or Flexible Mounting Lamp Watts ANSI Lamp Type Catalog Number➌ HPS PSMH Hub Size (Inches) HPS➋ PSMH 50 S68 CJLPB5075 25 Stanchion - One Hub 70 S62 CJLPB7075 00 S54 CJLPB075 50 S55 CJLPB575 75 M52 CJPPB775 50 S68 -/2 CJLSB5050 70 S62 -/2 CJLSB7050 00 S54 -/2 CJLSB050 50 S55 -/2 CJLSB550 75 M52 -/2 CJPSB750 Mounting Hoods Type Mounting Hub Size (Inches) Catalog Number Pendant One Hub CAP-75B 25 Stanchion One Hub -/2 CAS-50B Add suffix -R for Hot Restrike and -S for Smart Starter options. To order fixture with guard, add suffix -G (before adding voltage suffix). Add voltage -MT for 20/208/240/277 V. For 480 V, contact your sales representative. Add voltage suffix -MT for 20/208/240/277 V, or -48 for 480 V. Contact your sales representative for available 50 Hz ballasts. Refer to lamp manufacturer s data regarding lamp burning position restrictions. Visit our website at www.emerson.com or contact us at (800) 62-506. September 207 365

Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 75 W PSMH. 75 W MH. Medium Base. For Use with Threaded Metal Conduit. Class I, Division and 2, Groups C, D Class I, Division and 2, Groups B, C, D Lamp ANSI Lamp Type Hub Size Catalog Number Watts HPS PSMH/MH (Inches) HPS PSMH MH Pendant One Hub, Rigid or Flexible Mounting CJLP5075MT CJLP5075TTCN 50 S68 M0 CJLP500MT CJLP500TTCN CJLP7075MT CJLP7075TTCN 70 S62 M98 CJLP700MT CJLP700TTCN CJLP075MT CJLP075TTCN 00 S54 M90 CJLP00MT CJLP00TTCN CJLP575MT CJLP575TTCN 50 S55 CJLP50MT CJLP50TTCN CJPP775MT CJHP775MTCN CJPP775TTCN CJHP775TTCN 75 M52 CJPP70MT CJHP70MTCN CJPP70TTCN CJHP70TTCN Ceiling Four Hubs, Three Close-Up Plugs CJLC5075MT CJLC5075TTCN 50 S68 M0 CJLC500MT CJLC500TTCN CJLC7075MT CJLC7075TTCN 70 S62 M98 CJLC700MT CJLC700TTCN CJLC075MT CJLC075TTCN 00 S54 M90 CJLC00MT CJLC00TTCN CJLC575MT CJLC575TTCN 50 S55 CJLC50MT CJLC50TTCN CJPC775MT CJHC775MTCN CJPC775TTCN CJHC775TTCN 75 M52 CJPC70MT CJHC70MTCN CJPC70TTCN CJHC70TTCN Add suffix -R for Hot Restrike and -S for Smart Starter options. To order fixture with guard, add suffix -G before adding voltage suffix. For 480 V, contact your sales representative. Change voltage suffix -MT to -48 for 480 V. Change voltage suffix -TT (20/277/347 V) to -MT for 20/208/240/277 V, -C2 for 208 V, -C3 for 240 V, -C6 for 480 V, or -C7 for 600 V. These voltage suffixes have CSA Certification only. Refer to lamp manufacturer s data regarding lamp burning position restrictions. Fixtures with hubs listed for Class I, Group D, and Class II, Groups E, F, G only. Catalog numbers with -CN suffix have CSA Certification only. Shaded area indicates items suitable for Class I, Division, Group B. 366 Visit our website at www.emerson.com or contact us at (800) 62-506. September 207

Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 75 W PSMH. 75 W MH. Medium Base. For Use with Threaded Metal Conduit. Class I, Division and 2, Groups C, D Class I, Division and 2, Groups B, C, D Lamp ANSI Lamp Type Hub Size Catalog Number Watts HPS PSMH/MH (Inches) HPS PSMH MH Bracket Four Hubs, Three Close-Up Plugs CJLB5075MT CJLB5075TTCN 50 S68 M0 CJLB500MT CJLB500TTCN CJLB7075MT CJLB7075TTCN 70 S62 M98 CJLB700MT CJLB700TTCN CJLB075MT CJLB075TTCN 00 S54 M90 CJLB00MT CJLB00TTCN CJLB575MT CJLB575TTCN 50 S55 CJLB50MT CJLB50TTCN CJPB775MT CJHB775MTCN CJPB775TTCN CJHB775TTCN 75 M52 CJPB70MT CJHB70MTCN CJPB70TTCN CJHB70TTCN 25 Stanchion One Hub 50 S68 M0 -/4 or -/2 CJLS5050MT CJLS5050TTCN 70 S62 M98 -/4 or -/2 CJLS7050MT CJLS7050TTCN 00 S54 M90 -/4 or -/2 CJLS050MT CJLS050TTCN 50 S55 -/4 or -/2 CJLS550MT CJLS550TTCN 75 M52 -/4 or -/2 CJPS750MT CJHS750MTCN CJPS750TTCN CJHS750TTCN Add suffix -R for Hot Restrike and -S for Smart Starter options. To order fixture with guard, add suffix -G before adding voltage suffix. For 480 V, contact your sales representative. Change voltage suffix -MT to -48 for 480 V. Change voltage suffix -TT (20/277/347 V) to -MT for 20/208/240/277 V, -C2 for 208 V, -C3 for 240 V, -C6 for 480 V, or -C7 for 600 V. These voltage suffixes have CSA Certification only. Refer to lamp manufacturer s data regarding lamp burning position restrictions. Fixtures with hubs listed for Class I, Group D, and Class II, Groups E, F, G only. -/2" tapped hub furnished with -/2" to -/4" reducer. Catalog numbers with -CN suffix have CSA Certification only. Shaded area indicates items suitable for Class I, Division, Group B. Visit our website at www.emerson.com or contact us at (800) 62-506. September 207 367

Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 75 W PSMH. 75 W MH. Medium Base. For Use with Threaded Metal Conduit. Class I, Division and 2, Groups B,C, D Class I, Division and 2, Groups B, C, D Mounting Hoods Pendant One Hub Ceiling Four Hubs, Three Close-Up Plugs Bracket Four Hubs, Three Close-Up Plugs 25 Stanchion One Hub Hub Size (Inches) Catalog Number CAP-75 CAP-00 CAC-75 CAC-00 CALB-75 CALB-00 -/4 or -/2 CAS-50 Mounting Adapter with Connection Block Permits use of existing A-5 mounting hoods (AAC Ceiling or AALB Bracket) with the new Code Master 2 Fixture Unit. After removing existing fixture unit and adapter, screw in the new CMAD- Adapter. Then thread new fixture unit into the CMAD-. CMAD- Fixture Units Ballast body with globe. Indicate voltage desired by adding voltage suffix to fixture unit catalog number listed below. Type High Pressure Sodium High Power Factor (Min. P.F. 90%) Pulse Start Metal Halide Constant Wattage (Min. P.F. 90%) Metal Halide Constant Wattage (Min. P.F. 90%) Lamp Watts Fixture Unit Number Add Voltage Suffixes 20/208/240/277 20/277/347 480 V 50 CJB50L- MT TTCN 70 CJB70L- MT TTCN 48 00 CJB00L- MT TTCN 48 50 CJB50L- MT TTCN 48 75 CJB75P- MT TTCN 48 75 CJB75H- MT TT C6 -/2 Tapped hub furnished with -/2 to -/4 reducer. Mounting Hoods with hub listed for Class I, Group D; Class II, Groups E,F,G; and only. Add suffix -R for Hot Restrike and -S for Smart Starter options. Change voltage suffix -TTCN to -MTCN for 20/208/240/277 V, -C2 for 208 V, -C3 for 240 V, -C6 for 480 V, or -C7 for 600 V. These voltage suffixes have CSA Certification only. Shaded area indicates items suitable for Class I, Division, Group B. 368 Visit our website at www.emerson.com or contact us at (800) 62-506. September 207

Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 75 W PSMH. 75 W MH. Medium Base. For Use with Threaded Metal Conduit. Polyester Reflectors Description Catalog Number Standard Dome KR2-ST 30 Angle KR2-AN Standard Dome 30 Angle Three-Way Exit Sign Epoxy enameled steel 6 -high red lettering Mounts to Code Master Jr. fixture units in place of guard. Single Sided Exit Sign Epoxy enameled steel 6 -high red lettering Mounts to Code Master Jr. fixture units in place of guard. *Contact your sales representative regarding hazardous location suitability. Prismatic Glass Globe and Ring Assembly 50 W through 75 W CJEXRN AEXR-5R CJGL-75 Aluminum Guards 50 W through 75 W CJGU-5 Replacement Sockets 50 W through 75 W Medium base sockets CJMS-75 Connection Block 50 W through 75 W For all Code Master fixtures VPT-7 HPS Hot Restrike Restrikes HPS lamp immediately when power is restored after a momentary power interruption. Optional for fixture watts of 50, 70, 00 or 50 (HPS only) Add suffix -R Smart Starter Smart Starter is for HPS fixtures only. Incorporates a -/2-minute timer and performs as a conventional starter to normally start lamp. Removes itself from circuit if lamp burns out or is removed from socket. Eliminates starter failures caused by prolonged operation with cycling or failing lamps and simplifies finding their location which reduces maintenance and repair costs. Optional for all HPS and PSMH fixtures. Add suffix -S Visit our website at www.emerson.com or contact us at (800) 62-506. September 207 369

Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 75 W PSMH. 75 W MH. Medium Base. For Use with Threaded Metal Conduit. Lamp High Pressure Sodium HX-H.P.F. Ballast Amps Pulse Start Metal Halide HX-H.P.F. Super CWA Watts Volts Start Operating Start Operating 50 70 00 50 75 Fuse Quantity Required Fuse Kit Catalog Number HPS PSMH MH 20 0.58 0.58 CF-5 208 0.35 0.33 2 CF-3 240 0.3 0.29 2 CF-3 277 0.25 0.25 CF-2 347 480 20 0.90 0.82 CF-5 208 0.50 0.48 2 CF-3 240 0.44 0.4 2 CF-3 277 0.35 0.36 CF-2 347 0.30 0.30 CF-2 480 0.2 0.2 2 CF-2 20.30.5 CF-8 208 0.76 0.67 2 CF-5 240 0.66 0.58 2 CF-5 277 0.60 0.50 CF-3 347 0.45 0.30 CF-2 480 0.33 0.3 2 CF-3 20 2.00.66 CF-0 208.6 0.96 2 CF-5 240.00 0.83 2 CF-5 277.00 0.83 CF-5 347 0.52 0.56 CF-3 480 0.88 0.75 2 CF-5 20.30.80 0.80.80 CF-5 CF-5 208 0.75.04 0.50.00 2 CF-3 CF-3 240 0.65 0.90 0.40 0.90 2 CF-3 CF-3 277 0.55 0.80 0.40 0.80 CF-2 CF-2 347 0.27 0.65 0.25 0.65 CF-2 CF-2 480 0.35 0.45 0.5 0.45 2 CF-3 CF-2 Fuse Kit includes fuse, fuse holder and necessary hardware for field installation. Mounts easily in ballast body with one screw. Order one fuse for 20 V and 277 V, and 2 fuses for 208, 240 and 480 V. CF-2 = 2 Amp; CF-3 = 3 Amp; CF-5 = 5 Amp; CF-8 = 8 Amp; CF-0 = 0 Amp 35 W through 50 W HPS have H.P.F. High Reactance ballasts. 75 W PSMH 480 volts has CWA ballast. Multi-tap has CWA ballast. 347 V lamp has CSA Certification only. 370 Visit our website at www.emerson.com or contact us at (800) 62-506. September 207

Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 75 W PSMH. 75 W MH. Medium Base. For Use with Threaded Metal Conduit. Dimensions in Millimeters (Inches) Pendant Ceiling Bracket 6.3 mm (4.58" ) Ø 437.4 mm (7.22") 453.9 mm (7.87") Hub for " or " NPT Conduit 203.2 mm (8.00") 95.3 mm (3.75") 88.0 mm (7.40") 358.6 mm (4.2") 0.6 mm (4.00") 460.2 mm (8.2") 443.7 mm (7.47").390º Slot Four Places Hub for " or " NPT Conduit Four Sides 0.6 mm (4.00") 50.4 mm (5.92") 45º 4.3 mm (4.50") Ø 23.9 mm (0.94") 0.6 mm (4.00") 88.0 mm (7.40") 358.6 mm (4.2") 25.0 mm 2 (4.92" 2 ) 99.6 mm (3.92") 0.4 mm 0.4" Ø Four Holes 62.5 mm (2.46") 57.9 mm (2.28") 3.2 mm (.23") Hub for " or " NPT Conduit Four Sides 88.0 mm (7.40") 87.9 mm (3.46") 292. mm (.5") 349.3 mm (3.75") 50.8 mm (2.00") Ø Wiring Access Cover Both Sides 396.7 mm (5.62") 42.8 mm (6.25") 08.0 mm (4.25") 45.5 mm (.79") 406.4 mm (6.00") 203.2 mm (8.00") 25 Stanchion Exit Signs Reflectors 60.5 mm 2.38" Ø 24.3 mm (9.50") 54.9 mm (6.0") 60.5 mm (4.50") Ø 74.8 mm (6.88") 25.9 mm (8.50") 298.5 mm (.75") 69.9 mm (2.75") 378.5 mm (4.9") 203.2 mm (8.00") 258.3 mm (0.7").5 - NPT 25º 25º 406.4 mm (6.00") 428.8 mm (6.88") 235.0 mm (9.25") 304.8 mm (2.00") AEXR-5R 330.2 mm (3.00") 52.4 mm (6.00") 30 Angle 203.2 mm (8.00") 429.3 mm (6.9") CJEXRN Standard Dome 42.8 mm (6.25") Visit our website at www.emerson.com or contact us at (800) 62-506. September 207 37

* Photometric data is based on a fixture with a 50-watt clear High Pressure Sodium lamp (6,000 lumen), without guard. For candlepower values of fixtures with other HPS lamps, use the following multipliers: for a 00 W (9,500 lumen) HPS lamp 0.594; for a 70 W (6,400 lumen) HPS lamp 0.394; for a 70 W (5800 lumen) HPS lamp 0.363; for a 50 W (4,000 lumen) HPS lamp 0.25; for a 35 W (2,250 lumen) HPS lamp 0.4. For candlepower values of fixture with guard, multiply by 0.95. HPS Photometric Data Zone Lumens Total Luminaire Efficiency = 77.5% 0-0 32.97 CIE Type - General Diffuse REPORT NUMBER: CJL5G 0-20 9.6 Lamps: 50 W High Pressure Sodium lamp with Globe only * 20-30 33.87 30-40 349.57 Coefficients of Utilization - Zonal Cavity Method 40-50 804.55 Effective Floor Cavity Reflectance 0.20 50-60 93.29 % Ceiling Rcc 80 70 50 30 0 0 60-70 327.33 % Walls Rw 70 50 30 0 70 50 30 0 50 30 0 50 30 0 50 30 0 0 70-80 576.23 Zonal Lumen Summary 0 85 85 85 85 79 79 79 79 69 69 69 59 59 59 50 50 50 46 80-90 672.0 Zone Lumens % Lamp % Fixture 72 66 6 57 67 6 57 53 52 49 45 44 4 38 36 34 32 28 90-00 647.69 0-30 465.99 2.9 3.8 2 64 55 48 42 58 5 44 39 43 38 33 35 3 28 29 26 23 9 00-0 507.22 0-40 85.56 5. 6.6 3 57 47 39 33 52 43 36 30 36 30 26 30 25 2 24 20 7 4 0-20 22.25 0-60 283.4 7.6 22.7 4 5 40 32 26 47 37 30 24 3 25 2 25 2 7 20 6 3 0 20-30 607.8 0-90 7388.98 46.2 59.6 5 46 35 27 2 42 32 25 20 27 2 7 22 7 4 8 4 8 30-40 27.7 90-20 4376.7 27.4 35.3 6 42 3 23 8 39 29 22 7 24 8 4 20 5 6 2 9 6 40-50.62 90-30 4983.97 3. 40.2 7 39 28 20 5 36 26 9 4 2 6 2 8 3 0 4 0 7 5 50-60 0.35 90-50 502.76 3.3 40.2 8 36 25 8 3 33 23 7 2 9 4 0 6 8 3 9 6 4 60-70 0.07 90-80 503.20 3.3 40.4 9 33 23 6 3 2 5 0 8 2 9 5 0 7 2 8 6 4 70-80 0.02 80-0 2402.8 77.5 00.0 0 3 2 4 0 29 9 3 9 6 8 3 9 6 7 5 3 Zone Lumens Total Luminaire Efficiency = 66.9% REPORT NUMBER: CJL5ST 0-0 249.34 CIE Type - Direct Lamps: 50 W High Pressure Sodium lamp with 0-20 80.25 Spacing Standard Dome Reflector 20-30 450.35 Plane Criteria 30-40 495.68 0-80.44 Coefficients of Utilization - Zonal Cavity Method 40-50 920.69 90-270.44 Effective Floor Cavity Reflectance 0.20 50-60 2259.6 Diagonal.80 % Ceiling Rcc 80 70 50 30 0 0 60-70 846.4 % Walls Rw 70 50 30 0 70 50 30 0 50 30 0 50 30 0 50 30 0 0 70-80 54.69 Zonal Lumen Summary 0 80 80 80 80 78 78 78 78 74 74 74 7 7 7 68 68 68 67 80-90 25.07 Zone Lumens % Lamp % Fixture 73 69 66 64 7 68 65 63 65 63 6 62 6 59 60 59 57 56 90-00 0.70 0-30 2509.94 5.7 23.5 2 66 60 55 5 64 59 54 5 56 53 49 54 5 48 52 49 47 46 00-0 0.00 0-40 4005.62 25.0 37.4 3 59 52 46 42 58 5 46 4 49 44 4 47 43 40 45 42 39 38 0-20 0.00 0-60 885.92 5.2 76.5 4 54 45 39 35 52 45 39 34 43 38 34 4 37 33 40 36 33 3 20-30 0.00 0-90 0698.82 66.9 00.0 5 49 40 34 29 48 39 33 29 38 33 29 37 32 28 35 3 28 27 30-40 0.00 90-20 0.70 0.0 0.0 6 45 36 30 25 44 35 29 25 34 29 25 33 28 24 32 27 24 23 40-50 0.00 90-30 0.70 0.0 0.0 7 42 32 26 22 40 32 26 22 3 25 2 30 25 2 29 24 2 20 50-60 0.00 90-50 0.70 0.0 0.0 8 39 29 23 9 38 29 23 9 28 23 9 27 22 9 26 22 9 7 60-70 0.00 90-80 0.70 0.0 0.0 9 36 27 2 7 35 26 2 7 25 20 7 25 20 7 24 20 7 5 70-80 0.00 80-0 0699.52 66.9 00.0 0 34 24 9 5 33 24 9 5 23 9 5 23 8 5 22 8 5 4 Zone Lumens Total Luminaire Efficiency = 6.8% REPORT NUMBER: CJL5AN 0-0 58.3 CIE Type - Direct Lamps: 50 W High Pressure Sodium lamp with 0-20 482.43 Spacing 30 Angle Dome Reflector 20-30 904.49 Plane Criteria 30-40 63.85 0-80 2.08 Coefficients of Utilization - Zonal Cavity Method 40-50 479.08 90-270.38 Effective Floor Cavity Reflectance 0.20 50-60 630.56 Diagonal.54 % Ceiling Rcc 80 70 50 30 0 0 60-70 467.5 % Walls Rw 70 50 30 0 70 50 30 0 50 30 0 50 30 0 50 30 0 0 70-80 258.9 Zonal Lumen Summary 0 73 73 73 73 7 7 7 7 67 67 67 64 64 64 6 6 6 60 80-90 077.0 Zone Lumens % Lamp % Fixture 64 59 55 52 6 58 54 5 54 5 49 5 49 47 49 47 45 43 90-00 53.9 0-30 445.23 9.0 4.6 2 56 50 44 40 54 48 43 39 46 4 38 43 39 36 4 38 35 33 00-0 55.65 0-40 2609.08 6.3 26.4 3 5 43 36 3 49 4 36 3 39 34 30 37 33 29 35 3 28 27 0-20 52.23 0-60 578.73 35.7 57.8 4 46 37 30 25 44 36 30 25 34 29 24 32 28 24 30 26 23 22 20-30 8.33 0-90 9522.24 59.5 96.3 5 42 32 26 2 40 32 25 2 30 25 20 28 24 20 27 23 9 8 30-40 0.0 90-20 36.80 2.3 3.7 6 38 29 22 8 37 28 22 8 27 2 7 25 2 7 24 20 7 5 40-50 0.00 90-30 370.3 2.3 3.7 7 35 26 20 5 34 25 9 5 24 9 5 23 8 5 22 7 4 3 50-60 0.00 90-50 370.23 2.3 3.7 8 33 23 7 3 3 23 7 3 22 7 3 2 6 3 20 6 2 60-70 0.00 90-80 370.23 2.3 3.7 9 30 2 6 2 29 2 5 2 20 5 9 4 8 4 0 70-80 0.00 80-0 9892.48 6.8 00.0 0 28 9 4 0 27 9 4 0 8 3 0 7 3 0 7 3 0 9 372 Visit our website at www.emerson.com or contact us at (800) 62-506. September 207

* Photometric data is based on a fixture with a 75-watt clear Pulse Start Metal Halide lamp (4,000 lumen), without guard. For candlepower values of fixtures with other PSMH lamps, use the following multipliers: for a 00 W (8,500 lumen) PSMH lamp 0.607; for a 70 W (5,000 lumen) PSMH lamp 0.357. For candlepower values of fixture with guard, multiply by 0.95. PSMH Photometric Data Zone Lumens Total Luminaire Efficiency = 77.8% 0-0 46.64 CIE Type - General Diffuse REPORT NUMBER: CJP7G 0-20 76.99 Lamps: 75 W Pulse Start Metal Halide with Globe only * 20-30 380.0 30-40 480.30 Coefficients of Utilization - Zonal Cavity Method 40-50 042.35 Effective Floor Cavity Reflectance 0.20 50-60 252.88 % Ceiling Rcc 80 70 50 30 0 0 60-70 378.40 % Walls Rw 70 50 30 0 70 50 30 0 50 30 0 50 30 0 50 30 0 0 70-80 6.8 Zonal Lumen Summary 0 85 85 85 85 79 79 79 79 69 69 69 59 59 59 5 5 5 46 80-90 74.68 Zone Lumens % Lamp % Fixture 73 67 62 58 67 62 58 54 53 49 46 45 42 39 37 35 33 29 90-00 758.28 0-30 603.64 3.4 4.4 2 64 56 49 43 59 52 45 40 44 39 35 36 32 29 30 27 24 20 00-0 643.7 0-40 083.94 6.2 8.0 3 57 48 40 34 53 44 37 3 37 3 27 3 26 22 25 2 8 5 0-20 37.76 0-60 3379.8 9.3 24.8 4 52 4 33 27 48 38 3 25 32 26 22 26 22 8 2 7 4 2 20-30 694.24 0-90 8.07 46.3 59.6 5 47 36 28 22 43 33 26 2 28 22 8 23 8 5 9 5 2 9 30-40 27.3 90-20 4773.75 27.3 35. 6 43 32 24 9 40 29 23 8 25 9 5 20 6 2 6 3 0 7 40-50 3.4 90-30 5467.99 3.2 40.2 7 40 28 2 6 36 26 20 5 22 7 3 8 4 0 5 8 6 50-60 0.67 90-50 5498.26 3.4 40.2 8 37 26 9 4 34 24 7 3 20 5 7 2 9 3 0 7 5 60-70 0.08 90-80 5499.05 3.4 40.4 9 34 23 7 2 3 2 5 8 3 9 5 8 2 9 6 4 70-80 0.03 80-0 360.2 77.8 00.0 0 32 2 5 29 20 4 0 7 2 8 4 0 7 8 5 4 Zone Lumens Total Luminaire Efficiency = 66.4% REPORT NUMBER: CJP7ST 0-0 28.7 CIE Type - Direct Lamps: 75 W Pulse Start Metal Halide with 0-20 94.7 Spacing Standard Dome Reflector * 20-30 567.70 Plane Criteria 30-40 69.30 0-80.42 Coefficients of Utilization - Zonal Cavity Method 40-50 22.9 90-270.42 Effective Floor Cavity Reflectance 0.20 50-60 2339.53 Diagonal.76 % Ceiling Rcc 80 70 50 30 0 0 60-70 900.87 % Walls Rw 70 50 30 0 70 50 30 0 50 30 0 50 30 0 50 30 0 0 70-80 568.93 Zonal Lumen Summary 0 79 79 79 79 77 77 77 77 74 74 74 7 7 7 68 68 68 66 80-90 45.98 Zone Lumens % Lamp % Fixture 72 69 66 64 70 67 65 63 65 63 6 62 60 59 60 58 57 56 90-00.23 0-30 2763.57 5.8 23.8 2 65 60 55 5 64 58 54 5 56 52 49 54 5 48 52 49 47 46 00-0 0.00 0-40 4454.87 25.5 38.3 3 59 52 46 42 57 5 46 4 49 44 4 47 43 40 45 42 39 38 0-20 0.00 0-60 9006.3 5.5 77.5 4 54 46 39 35 52 45 39 35 43 38 34 4 37 34 40 36 33 32 20-30 0.00 0-90 622.09 66.4 00.0 5 49 40 34 29 48 40 34 29 38 33 29 37 32 29 35 3 28 27 30-40 0.00 90-20.23 0.0 0.0 6 45 36 30 25 44 35 29 25 34 29 25 33 28 25 32 28 24 23 40-50 0.00 90-30.23 0.0 0.0 7 42 32 26 22 4 32 26 22 3 26 22 30 25 22 29 25 2 20 50-60 0.00 90-50.23 0.0 0.0 8 39 29 23 9 38 29 23 9 28 23 9 27 22 9 26 22 9 8 60-70 0.00 90-80.23 0.0 0.0 9 36 27 2 7 35 26 2 7 26 2 7 25 20 7 24 20 7 6 70-80 0.00 80-0 623.32 66.4 00.0 0 34 25 9 6 33 24 9 6 24 9 5 23 8 5 22 8 5 4 Zone Lumens Total Luminaire Efficiency = 63.2% REPORT NUMBER: CJP7AN 0-0 238.28 CIE Type - Direct Lamps: 75 W Pulse Start Metal Halide with 0-20 739.68 Spacing 30 Angle Dome Reflector * 20-30 242.92 Plane Criteria 30-40 49.36 0-80 2.0 Coefficients of Utilization - Zonal Cavity Method 40-50 770.34 90-270.60 Effective Floor Cavity Reflectance 0.20 50-60 739.56 Diagonal.62 % Ceiling Rcc 80 70 50 30 0 0 60-70 484.79 % Walls Rw 70 50 30 0 70 50 30 0 50 30 0 50 30 0 50 30 0 0 70-80 97.57 Zonal Lumen Summary 0 75 75 75 75 73 73 73 73 69 69 69 65 65 65 62 62 62 6 80-90 689.02 Zone Lumens % Lamp % Fixture 66 63 59 56 64 6 58 55 58 55 53 55 53 5 52 50 49 47 90-00 254.20 0-30 2220.87 2.7 20. 2 60 53 48 44 58 52 47 43 49 45 42 47 43 4 44 42 39 38 00-0 05.48 0-40 372.23 2.2 33.6 3 54 46 40 36 52 45 40 35 43 38 34 4 37 33 39 35 32 3 0-20 35.72 0-60 7222.3 4.3 65.3 4 49 4 34 30 47 39 34 29 38 33 29 36 3 28 34 30 27 26 20-30 4.95 0-90 0593.52 60.5 95.8 5 45 36 30 25 43 35 29 25 33 28 24 32 27 24 30 26 23 22 30-40 8.72 90-20 395.4 2.3 3.6 6 4 32 26 22 40 3 26 2 30 25 2 29 24 2 27 23 20 9 40-50 6.06 90-30 437.36 2.5 4.0 7 38 29 23 9 37 28 23 9 27 22 8 26 2 8 25 2 8 6 50-60 4.53 90-50 452.3 2.6 4.0 8 35 26 2 7 34 26 20 7 25 20 6 24 9 6 23 9 6 4 60-70 2.20 90-80 459.54 2.6 4.2 9 33 24 9 5 32 24 8 5 23 8 5 22 7 4 2 7 4 3 70-80 0.68 80-0 053.05 63.2 00.0 0 3 22 7 3 30 22 7 3 2 6 3 20 6 3 9 5 3 2 Visit our website at www.emerson.com or contact us at (800) 62-506. September 207 373